The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT.

Similar documents
THE WALL-MOUNT GAS/ELECTRIC - WG-SERIES

THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS

THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT

GREEN REFRIGERANT R-410A

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

GREEN REFRIGERANT R-410A

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

V High Efficiency Series

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

GREEN REFRIGERANT R-410A

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

TECHNICAL SPECIFICATIONS

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Multi-Position, Multi-Speed Gas Furnaces

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

S/T Ratio. Input BTU/h

PCB COMMERCIAL SERIES

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

2SG13 60HZ P A C K A G E D G A S / E L E C T R I C

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

13 GCS X A X Nominal SEER Minor Revision Number

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

DESCRIPTION FEATURES

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

CHP

ELITE SERIES R-410A Ready - Multi-Position

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

13 SEER Light Commercial 3 Phase

D M S 760 C01 A A 1 1

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

GR4GA Series Single Packaged Gas/Electric Units

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

CAC SERIES 12-1/2 Thru 20 Ton

REPLACEMENT PARTS MANUAL

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

CSA6. Product Specifications. SoftSound SXC 2600

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

TECHNICAL SPECIFICATIONS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Geo-Trio High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A

PGF / PGC SERIES CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT. PGF = Standard Models PGC = California Models with NOX baffles

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

P5RF Series Single Packaged Air Conditioner Single Phase

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

PACKAGE AIR CONDITIONERS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner

Q7RE Series Single Packaged Heat Pump, Single Phase

PGB SERIES 10 SEER PRODUCT SPECIFICATIONS. Self-Contained Gas/Electric Packaged Air Conditioner

RGMA Series Package Gas Electric SPECIFICATIONS

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D1HG/D1HE 180 & D-0602

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h

PHB SERIES 7-1/2 and 10 TON

14 SEER R -410A PACKAGE DUAL FUEL HEAT PUMP 2 to 5 TONS Two -Stage, Gas Heating / Electric Heating and Cooling Unit

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204

N2AE - 50 Hz PRODUCT SPECIFICATIONS

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

Transcription:

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37, to 12,5 BTUH Heating Capacity Green Refrigerant R-41A High Efficiency Low Sound Level The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained energy efficient system which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, portable structures, correctional facilities, retail stores or other commercial applications. Factory or field installed accessories are available to meet specific job requirements. Engineered Features Multi-Capacity Two-Stage: Simple thermostatic control seamlessly stages the compressor and indoor airflow rate between high and low capacity operations without cycling the compressor. This helps to maximize comfort, humidity control, energy efficiency and overall reduction in compressor cycling for improved system life. Step Capacity Compressor: Copeland step-capacity (2-stage) scroll compressors are designed for increased efficiency, quieter operation and improved reliability for longer life. Double isolated floating mounting base, compressor sound blanket and discharge muffler for reduced sound level. R-41A Refrigerant: Designed with R-41A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 21 EPA requirements. Thermal Expansion Valves: All models use TXV. Liquid Line Filter Drier: Protects system against moisture. Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. High & Low Pressure Switches are Auto-Reset Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Compressor Control Module: Standard on all units. Built-in off-delay timer adjustable from 3 seconds to 5 minutes. 2-minute on-delay if power interrupt. 12-second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. Crankcase Heaters: Factory installed crankcase heaters are standard on all models. This helps to ensure ease of start at low temperatures and improves compressor life. Phase Rotation Monitor: Standard on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Twin Blowers: Move air quietly. All models feature variable speed blower motors providing automatic airflow adjustment for high static or free blow (non-ducted) operation at a very low sound level. Motor overload protection is standard on all models. ECM Indoor Blower Motor: Features a variable speed motor providing super-high efficiency, low sound levels and soft-start capabilities. The motor is self-adjusting to provide the proper airflow rate for the staged capacity, and for higher static pressure in ducted installations without user adjustment or wiring changes. Ventilation Controller: Automatically adjusts damper position to maintain the desired ventilation airflow rate up to 48 cfm of fresh air during any operation mode. Fully closes during unoccupied modes. Factory set for 48 cfm. Also, CO 2 sensor ready - just add CO 2 sensor for demand ventilation based on CO 2 level in the space. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or rotary disconnect switch. Heat Exchanger: Heavy duty 18-gauge stainless steel tubular heat exchanger. Mechanically joined construction. Ten-year warranty. In-Shot Burners: Advanced burner design, quiet operation. Integrated DSI Control: Direct spark ignition control and remote sensor delivers smooth, proven ignition sequence. Timed blower control and diagnostics are also features of integrated control. Gas Controls: Honeywell gas valve and burner orifices are factory standard for natural gas. High altitude kits available. Field convertible to LP gas with certified conversion kit. Filter Service Door: Separate service door provides easy access for filter change. Pre-Painted 2 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 1 hours of salt spray tests per ASTM B117-3. 16 Gauge Zinc Coated Unit Base Two-Inch, Pleated Disposable Air Filters: Are standard equipment. Condenser Fan and Motor Shroud Assembly: Slides out for easy access. Circuit Breakers/Rotary Disconnect: Standard on all versions of single (23/28 volt) and three phase (23/28 volt) equipment. Rotary disconnects are standard on all versions of three phase (46 volt) equipment. Slope Top: Standard feature for water run-off. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. Top Rain Flashing: Standard feature on all models. Ventilation Options: Several ventilation options are available and can be factory or field installed. Complies with efficiency requirements of ANSI/ASHRAE/IESNA 9.1-21. Certified to ANSI/ARI Standard 39-23 for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 1995/CSA 22.2 No. 236-5, Fourth Edition. Intertek ETL Listed to Standard for Gas-Fired Central Furnaces ANSI Z21.47-26, CSA 2.3-26 Fifth Edition, Addenda A dated 1-1-27, Addenda B dated 6-1-28. Commercial Product - Not intended for Residential application. Page 1 of 12

Specifications MODELS WG3S2-A WG3S2-B WG3S2-C WG4S2-A WG4S2-B WG4S2-C WG5S2-A WG5S2-B WG5S2-C Electrical Rating 6 Hz 23/28-1 23/28-3 46-3 23/28-1 23/28-3 46-3 23/28-1 23/28-3 46-3 Operating Voltage Range 197-253 187-253 414-56 197-253 187-253 414-56 197-253 187-253 414-56 Minimum Circuit Ampacity 27 23 12 36 27 14 45 31 15 *Field Wire Size/ 8 1 14 8 1 12 8 8 12 Ground Wire Size 1 1 14 1 1 12 1 1 12 ** Delay Fuse - Max. 4 3 15 45 4 2 6 45 2 Compressor Voltage 23/28 23/28 46 23/28 23/28 46 23/28 23/28 46 Rated Load Amps 11.6 / 12.9 8.8 / 9.9 6.7 15. / 17.8 1.4 / 11.8 5.4 2.9 / 23. 12.8 / 14.1 6.2 Branch Circuit Selection Current 15.3 11.7 5.8 21.2 14.1 6.5 27.2 16.5 7.2 Lock Rotor Amps 83 73 38 14 83.1 41 152.9 11 52 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Fan Motor & Condenser Fan Motor--HP--RPM-SPD 1/3-85-2 1/3-85-2 1/3-85-1 1/3-85-2 1/3-85-2 1/3-85-1 1/3-85-2 1/3-85-2 1/3-85-1 Fan Motor--Amps 2.5 2.5 1.3 2.5 2.5 1.3 2.5 2.5 1.3 Fan--DIA/CFM 24" - 27 24" - 27 24" - 27 24" - 27 24" - 27 24" - 27 24" - 27 24" - 27 24" - 27 Blower Motor & Evap. Blower Motor--HP-RPM-SPD 1/2 Variable 1/2 Variable 1/2 Variable 3/4 Variable 3/4 Variable 3/4 Variable 3/4 Variable 3/4 Variable 3/4 Variable Blower Motor--Amps 3.6 3.6 3.6 4.7 4.7 4.7 6. 6. 6. CFM Cooling - 1st Stage 8 8 8 11 11 11 13 13 13 CFM Cooling - 2nd Stage 11 11 11 15 15 15 17 17 17 Filter Size 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 Charge (R-41A) 156 156 156 24 24 24 246 246 246 Shipping Weight --LBS. 585 585 63 685 685 73 71 71 5 * Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. ** Maximum time delay fuse or HACR type circuit breaker. Add 45 lbs. for factory installed WGSCRVMP-5 Commercial Room Ventilator or WGSEIFM-5 Economizer, and 9 lbs. for WGSERV-5 Energy Recovery Ventilator. Cooling System Capacity, Efficiency & Airflow Ratings Models WG3S2 WG4S2 WG5S2 Cooling Capacity BTUH, 2nd Stage Operation 35, 46,5 56,5 EER 2nd Stage Operation 11.3 11.7 11.2 Rated CFM, Wet Coil 11 14 16 Cooling Capacity BTUH, 1st Stage Operation 24, 33,6 41,5 EER 1st Stage Operation 11.1 11.8 11.5 Rated CFM, Wet Coil 8 11 13 IPLV (Certified to ARI Standard 39-23) 14.6 15.6 14.7 Heating System Capacity, Efficiency, Derate & Airflow Ratings Factory Standard Heating Capacity Options & Performance See Note Below Model Heating Input Code A B C D Input BTUH 5,, 1, 125, Output BTUH (Heating Capacity) k 41, 61,5 82, 12,5 Thermal Efficiency (T.E.) k 82. 82. 82. 82. Temperature Rise Range (F) 25-55 3-6 4-7 5-8 Constant Heating CFM/Constant Rise (F) 96/35 11/5 13/5 144/7 1% Field Derate Heating Capacity Options & Performance See Note Below Model Heating Input Code A B C D Input BTUH 45, 68, 9, 113, Output BTUH (Heating Capacity) k 37, 55,5 74, 93, Thermal Efficiency (T.E.) k 82. 82. 82. 82. Temperature Rise Range (F) 25-55 3-6 4-7 5-8 Constant Heating CFM/Constant Rise (F) 96/3 11/45 13/45 144/ j Any input can be selected for each model. k Heating ratings certified in accordance with ANSI Z21.47-26. Page 2 of 12

Indoor Blower Performance MODEL Rated ESP Max ESP Continuous CFM Rated 1st Stage Cooling CFM Rated 2nd Stage Cooling CFM 5, BTU Input Heating CFM, BTU Input 1, BTU Input WG3S2.15.5 8 8 11 96 11 13 144 WG4S2.2.5 825 11 14 96 11 13 144 WG5S2.2.5 85 13 16 96 11 13 144 Motor will deliver consistent CFM through voltage supply range with no deterioration (197-253V for 23/28V models, 414-56V for 46V models). Continuous CFM is the total air being circulated during continuous (manual) fan mode. Will occur automatically with a call for Y1 signal from thermostat. Will occur automatically with a call for Y2 signal from thermostat. Will occur automatically with a call for W signal from thermostat. Constant CFM of Variable Speed Motor should maintain mid-rise temperature differential through range of allowable static. Ventilation System Packages 125, BTU Input Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All ventilation packages can be built-in at the factory, or field-installed at a later date. BLANK OFF PLATE - WGSBOP STANDARD A blank off plate is installed on the inside of the service door. It covers the air inlet openings which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. COMMERCIAL ROOM VENTILATOR - WGSCRVMP-5 OPTIONAL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to 5% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper with integral bug screen. Automatic control is integrated to maintain desired ventilation air at the various supply airflows while on Stage 1, Stage 2 or ventilation modes of operation. COMMERCIAL ROOM VENTILATOR The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. The CRV is power open - spring return on power loss. Complies with ANSI/ASHRAE Standard 62.1 Ventilation for Acceptable Indoor Air Quality. CO 2 Sensor Ready: WGSCRVMP-5 is designed for CO 2 based on ventilation control by simply wiring in a field installed CO 2 sensor if desired. ECONOMIZER ENERGY RECOVERY VENTILATOR ECONOMIZER - WGSJIFM-5 OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. Standard Features: One Piece Construction - Easy to install with no mechanical linkage adjustment required. Exhaust Air Damper - Built in with positive closed position. Provides exhaust air capability to prevent pressurization of tight buildings. Actuator Motor - 24 volt, power open, spring return with built in torque limiting switch. Proportioning Type Control - for maximum free cooling economy and comfort. Moisture Eliminator & Prefilter - permanent, washable aluminum construction. Enthalpy Control - adjustable to monitor outdoor temperature and humidity. Honeywell JADE electronic economizer module with precision settings and diagnostics. Mixed Air Sensor - to monitor outside and return air to automatically modulate damper position. WALL-MOUNT ENERGY RECOVERY VENTILATOR - WGSERV-5 OPTIONAL The wall-mount energy recovery ventilator (WGSERV-5) is a highly innovative approach to address indoor air quality ventilation requirements as established by ANSI/ASHRAE Standard 62.1. The WGSERV-5 allows up to 45 CFM (depending upon speed setting) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 74% during summer and 8% during winter conditions. The WGSERV-5 consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The WGSERV-5 is designed to be internally mounted behind the service door in the WGS Gas/Electric units. It can be built-in at the factory or field installed as an option. WGSERV-5 can be independently adjusted for intake and exhaust rates. NOTE: See Page 4 for WGSCRV Performance Data & Page 5 & 6 for WGSERV Performance Data Page 3 of 12

WGSEIFM-5 Economizer and WGSCRVMP-5 Commercial Ventilator Airflow 7 WG3S Ventilation Airflow 6 5 Ventilation Airflow (CFM) 4 3 Stage #2 Operation Blower Only & Stage #1 Operation 2 1 2.5 5 7.5 1 12.5 15 17.5 2 22.5 25 27.5 3 Vent Position 9 WG4S Ventilation Airflow 8 7 Ventilation Airflow (CFM) 6 5 4 3 Stage #2 Operation Stage #1 Operation Blower Only 2 1 2.5 5 7.5 1 12.5 15 17.5 2 22.5 25 27.5 3 Vent Position WG5S Ventilation Airflow 1 9 8 Ventilation Airflow (CFM) 7 6 5 4 3 Stage #2 Operation Stage #1 Operation Blower Only 2 1 2.5 5 7.5 1 12.5 15 17.5 2 22.5 25 27.5 3 Vent Position Page 4 of 12

Energy Recovery Ventilator Performance Data WGSERV-A5 (23V) & WGSERV-C5 (46V) APPLICATION DATA WGSERV-A5A, -C5A SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS DB/62 WB) Ambient O.D. VENTILATION RATE -- 45CFM High Speed (Black) 6% EFFICIENCY VENTILATION RATE -- 37 CFM Medium Speed (Blue) 62% EFFICIENCY VENTILATION RATE -- 28 CFM Low Speed (Red) 64% EFFICIENCY DB/ WB F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL 15 7 214 1458 1458 1458 1458 1458 6884 12879 8748 8748 8748 8748 8748 4131 17649 11988 11988 11988 11988 11988 5661 1942 7433 7433 7433 7433 7433 351 13356 972 972 972 972 972 4284 8548 586 586 586 586 586 2742 1 8 7 6 315 214 1215 1215 1215 1215 1215 1215 1215 1944 9314 22 189 12879 729 729 729 729 729 729 729 1161 5589 121 259 17649 1156 999 999 999 999 999 999 999 1591 79 166 18 1942 9864 4749 13 196 13356 6 6 6 6 6 6 6 124 5796 126 12544 8548 776 379 8 95 9 8 7 6 8 7 6 3159 214 972 972 3159 214 729 729 972 972 972 972 972 729 729 729 729 729 2187 11744 2632 243 141 562 18954 12879 18954 12879 13122 747 1579 1458 855 337 25974 17649 1156 25974 17649 1156 17982 97 2164 1998 115 4162 1614 1942 1614 1942 11149 5987 1342 12388 7226 258 196 13356 648 648 196 13356 648 648 648 648 648 1368 738 1638 1512 882 315 1258 8548 1258 8548 293 293 293 293 293 293 293 879 4677 148 9677 5645 216 85 8 7 6 3159 214 486 486 486 486 486 486 486 2673 16 7492 18954 12879 1638 9963 4495 25974 17649 1156 21978 133 616 1614 1942 13626 84 3819 196 13356 324 324 324 324 324 324 324 16632 1332 4662 1258 8548 1644 6612 2983 8 7 6 214 4252 243 243 243 243 243 9922 1822 12879 2551 1458 1458 1458 1458 1458 11421 5953 193 17649 1156 3496 1998 1998 1998 1998 1998 151 8158 1498 1942 2168 1239 1239 1239 1239 1239 974 558 929 13356 2646 1512 1512 1512 1512 1512 11844 6174 1134 8548 1693 968 968 968 968 968 8 3951 726 7 6 4252 4252 2551 2551 1156 3496 1156 3496 2168 2168 2646 2646 1693 1693 LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery Ambient O.D. WGSERV-A5A, -C5A WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS 7 F DB) 45 CFM 77% EFFICIENCY VENTILATION RATE 37 CFM 78% EFFICIENCY 28 CFM 79% EFFICIENCY DB/ F WVL WHR WVL WHR WVL WHR 243 187 2 156 151 119 6 486 374 4 312 32 239 55 729 561 599 468 454 358 5 972 748 8 623 478 45 1215 936 999 779 6 597 4 1458 1123 1199 935 97 717 35 171 191 1399 191 158 836 3 1944 1497 1598 1247 121 956 25 2187 1684 1798 143 1361 1 2 243 1871 1998 1558 1512 1195 15 2673 258 2198 1714 1663 1314 NOTE: Sensible performance only is shown for winter application. Page 5 of 12

This page intentionally left blank. Page 6 of 12

Important Information Concerning Altitude Impact on Heating Input Ratings Heating input, and thus heating output, decreases with altitude. No orifice change is required up to 6, feet elevation and derate occurs naturally due to altitude impact. Natural gas models may require orifice change based on BTU content of gas. See Natural Gas Orifice and Altitude Tables on next page for details. For Propane Gas see the Propane Gas Conversion Table below. Above 6, feet elevation orifice changes are required, and capacity reductions are a function of altitude impact and orifice change. Pressure switch change is required above 6, feet elevation. For Natural Gas see the Orifice and Altitude Tables on next page. For Propane Gas see the Propane Gas Conversion Table below. NATURAL GAS DERATE CAPACITIES WG Rated Input Sea Level 1 2 3 4 5 6 7 8 9 1, 45, 45, 43,56 42,12 4,68 39,6 38,88 37,98 37,44 36,72 36,27 35,64 5, 5, 48,4 46,8 45,2 44, 43,2 42,2 41,6 4,8 4,3 39,6 68, 67,5,34 63,18 61,2 59,4 58,32 56,97 56,16 55,8 54,45 53,46,, 72,6 7,2 67,8 66, 64,8 63,3 62,4 61,2 6,45 59,4 9, 9, 87,12 84,24 81,36 79,2 77,76,96 74,88 73,44 72,54 71,28 1, 1, 96,8 93,6 9,4 88, 86,4 84,4 83,2 81,6 8,6 79,2 112,5 112,5 18,9 15,3 11,7 99, 97,2 94,95 93,6 91,8 9,6 89,1 125, 125, 121, 117, 113, 11, 18, 15,5 14, 12, 1, 99, PROPANE (LP) DERATE CAPACITIES WG Rated Input Sea Level 1 2 3 4 5 6 7 8 9 1, 4,5 45, 6, 68,, 81, 9, 1, 112,5 125, 4,5 45, 6, 67,5, 81, 9, 1, 112,5 125, 39,852 44,28 59,778 66,42 73,8 79,74 88,56 98,4 11,7 123, 39,528 43,92 59,292,88 73,2 79,56 87,84 97,6 19,8 122, 39,24 43,56 58,86,34 72,6 78,48 87,12 96,8 18,9 121, 38,556 42,84 57,834 64,26 71,4 77,112 85,68 95,2 17,1 119, 38,232 42,48 57,348 63,72 7,8 76,464 84,96 94,4 16,2 118, 37,584 41,76 56,376 62,64 69,6,168 83,52 92,8 14,4 116, 36,612 4,68 54,918 61,2 67,8 73,224 81,36 9,4 11,7 113, 35,64 39,6 53,46 59,4 66, 71,28 79,2 88, 99, 11, 34,344 38,16 51,516 57,24 63,6 68,688 76,32 84,8 95,4 16, 32,724 36,36 49,86 54,54 6,6,448 72,72 8,8 9,9 11, Gas Pressure Inches W.C. Minimum permissible gas supply pressure for purpose of input adjustment: Natural 4.5 LP 11. Maximum permissible gas supply pressure for purpose of input adjustment: Natural 11. LP 13. Manifold Pressure: Natural 3.5 LP 1. Propane Gas Conversion Kits -- Fits All WG-Series Models PROPANE (LP) GAS -- Use Gas Conversion Kits As Indicated MODELS Propane Gas Conversion Kit Use WGCK-1 Use WGCK-2 Gas Up to 6 Feet 61 to 8 Feet 81 to 1, Feet Factory Heat Requires Pressure Requires Pressure Standard Value Switch Change and Switch Change and Input BTU/Cu. Ft. Install Orifice Orifice as Shown Orifice as Shown WG3S 25, BTU 25 1.5 1.5 1.4 Per Burner Pressure Switch Standard (.55) Pressure Switch (.42) Included in Conversion Kit WG4S WG5S Optional 1% Field Converted Derate 22,5-22, BTU Per Burner All orifice sizes shown are millimeters (mm). Gas Heat Value BTU/Cu. Ft. Up to 6 Feet Install Orifice 61 to 8 Feet Requires Pressure Switch Change and Orifice as Shown 81 to 1, Feet Requires Pressure Switch Change and Orifice as Shown 25 1.45 1.45 1.4 Pressure Switch Standard (.55) Pressure Switch (.42) Included in Conversion Kit Page 7 of 12

Natural Gas Orifice and Altitude Tables Factory Standard Input 25, BTU Per Burner Gas Heat* Value BTU/Cu. Ft. Up to 6 Feet No Changes Except For BTU Content 61 to 8 Feet Requires Pressure Switch Change and Orifice Change Based on BTU Content 81 to 1, Feet Requires Pressure Switch Change and Orifice Change Basesd on BTU Content 7-749 2.9 2.8 2.7-799 2.8 2.7 2.6 8-849 2.7 2.6 2.5 85-899 2.6 2.5 2.45 9-949 2.5 2.45 (2.4) 95-999 2.45 (2.4) 2.35 1-149** (2.4) 2.35 [2.3] 15-11 [2.3] 2.25 2.2 Pressure Switch Standard (.55) Order 862-189 High Altitude Pressure Switch Kit (.42) (2.4) is the standard factory installed orifice size [2.3] orifices are shipped with the unit for field installed optional 1% derate Optional 1% Field Converted Derate 22,5 BTU Per Burner Gas Heat* Value BTU/Cu. Ft. Up to 6 Feet No Changes Except For BTU Content 61 to 8 Feet Requires Pressure Switch Change and Orifice Change Based on BTU Content 81 to 1, Feet Requires Pressure Switch Change and Orifice Change Basesd on BTU Content 7-749 2. 2.7 2.6-799 2.7 2.6 2.5 8-849 2.6 2.5 85-899 2.5 2.45 (2.4) 9-949 (2.4) 2.35 [2.3] 95-999 2.35 [2.3] 2.25 1-149** [2.3] 2.25 2.2 15-11 2.25 2.25 2.2 Pressure Switch Standard (.55) Order 862-189 High Altitude Pressure Switch Kit (.42) [2.3] orifices are shipped with the unit for field installed optional 1% input rate. (2.4) is the factory installed orifice size for full rated input * At standard conditions: 3. Inches Mercury, 6F, Saturated,.6 Specific Gravity ** All Natural Gas factory orifice sizing and standard input ratings based on nominal 125 BTU per cubic foot gas and sea level conditions. All other orifice sizes shown are available as individual items. See Orifice charts below for part numbers and number required. Bard Part No. Orifice Size (mm) Orifice Diameter 91-92 2.1.826 91-88 2.15.846 91-87 2.2.866 91-86 2.25.885 91-82 2.3.95 91-85 2.35.925 91-79 2.4.945 91-84 2.45.964 91-93 2.5.984 91-94 2.6.124 91-95 2.7.163 91-96 2..182 91-97 2.8.112 91-98 2.9.1142 No. of Orifices Required Based on Unit Input Rating 45, (2) 5, (2) 68, (3), (3) 9, (4) 1, (4) 113, (5) 125, (5) Page 8 of 12

2nd Stage Cooling Application Data - Outdoor Temperature Model DB/WB Cooling Capacity 5 F 55 F 6 F F 7 F F 8 F 85 F 9 F 95 F 1 F 15 F 11 F 115 F WG3S2 WG4S2 WG5S2 /62 8/67 85/72 /62 8/67 85/72 /62 8/67 85/72 44, 32,9 49,7 32,825 52,25 32,6 56,25 4,4 62,35 41,4 69,425 41,625 69,7 49,8 74, 48,325 79,8 46, 43,35 32,2 48,15 32,15 5,8 32, 54,5 39,7 6,6 4,7 67,525 4,8 67,8 49,5 72,7 47,55 78, 46, 41,9 31,625 46,55 31,5 49,5 31,35 52,9 39,15 58,85 39,925,625 4,13,9 48,225 7,8 46,7 76,2 45,5 4,5 3,9 44,925 3,825 48,35 3, 51,45 38,525 57,1 39,15 63,725 39,3 64, 47,4 68,825 46, 74,4 44,925 39,2 3,35 43,325 3,1 47,125 3,125 49,925 37,925 55,35 38,3 61,825 38,625 62,1 46,5 66,85 45,225 72,6 44,35 37,8 29,7 41,7 29,5 45,9 29,5 48,4 37,3 53,6 37,6 59,9 37,9 6,25 45,8 64,85 44,4 7,8 43, 36,35 29,25 39,925 28, 44,85 28,825 46,95 36,8 51,825 36,8 57,9 37,1 58,325 44,9 62,7 43,5 69,125 43,2 34,8 28,35 38,15 28, 43,8 28,15 45,5 36,3 5,5 36, 56,5 36,45 56,4 44,15 6,6 42,6 67,45 42, 33,425 27, 36,3 27,225 42, 27,4 44,5 35,7 48,2 35,1 54,125 35,725 54,4 43,325 58,6 41,7,725 42,1 31,9 26,9 34,6 26,4 41,725 26,7 42,6 35,2 46,5 34,3 52,2 34,9 52,525 42,525 56,5 4,8 64,125 41,55 3,85 26,4 33,625 26,1 39,7 26,4 4,7 34,2 44,85 33,725 5,3 34,1 5,8 41,725 54,95 4,4 61,8 4,8 29,725 26, 32,6 25,9 37,85 26, 38,95 33,15 43,2 33,1 48,55 33,3 49, 4,925 53,4 4,15 59,4 4,2 28,625 25,5 31,725 25,6 35,925 25,6 37,125 32, 41,55 32,45 46,725 32,5 47,35 4,125 51,85 39,825 57,15 39,525 27,5 25, 3, 25,3 34, 25,2 35,3 31, 39,9 31,8 44,9 31,8 45,6 39,3 5,3 39,5 54,85 38,8 1st Stage Cooling Application Data - Outdoor Temperature Model DB/WB Cooling Capacity 5 F 55 F 6 F F 7 F F 8 F 85 F 9 F 95 F 1 F 15 F 11 F 115 F WG3S2 WG4S2 WG5S2 /62 8/67 85/72 /62 8/67 85/72 /62 8/67 85/72 3,925 23,35 35,5 23,6 38, 22,9 41,2 29, 45,6 3, 51,525 3,85 5, 36,8 58,55 37,85 62,125 35,95 29,825 22, 33, 23,5 37,4 22,45 4, 29,125 44,35 29,4 5, 3,15 48, 36,325 56,6 37,15 6,45 35,55 28,725 22,15 32,45 22,425 36,5 21,925 38,8 28,6 43,25 28,8 48,4 29,45 47,5 35,85 54, 36,45 58,7 35,15 27,625 21,55 31,15 21,8 34,7 21,4 37,6 28, 41,7 28,2 46,95 28, 46,25 35,3 52,7 35, 57,1 34, 26,525 2,95 29,85 21,1 33,35 2,8 36,4 27,55 4,35 27,6 45,425 28,5 45, 34,9 5, 35,5 55,425 34,35 25,4 2,4 28,6 2,5 32, 2,4 35,3 27, 39, 27,1 43,9 27,4 43, 34,45 48,85 34,35 53,8 33,9 24,225 19, 27,2 19,7 3,55 19,825 34,1 26,4 37, 26,4 42,3 26, 42,6 34, 46,7 33,525 52,1 33,55 23,5 19,1 25,8 19,5 29,1 19,25 32,9 25,95 36,3 25,85 4,7 25,9 41,6 33,7 44,7 32,7 5,55 33,2 21,8 18,45 24,4 18,325 27, 18,6 31,7 25,425 34,95 25,225 39,1 25,15 4,525 33,325 42,6 31,8 48,925 32,85 2,7 17,825 23, 17,5 26,15 18,125 3,525 24,925 33,6 24,6 37,45 24,35 39,425 32,95 4,5 31, 47,325 32,55 19,8 17,45 22,15 17,325 25,25 17,825 29,325 24,35 32,325 24,125 36,25 23,95 37,5 32,1 39,15 3,85 45,4 31,85 19,5 17, 21,3 17, 24,35 17,525 28,125 23,7 31,5 23, 35,5 23,55 35,5 31,225 37,8 3,625 43,625 31,1 18,225 16,7 2,45 16,825 23,45 17,225 26,925 23,2 29,7 23,1 33,8 23,15 33, 3,35 36,45 3,4 41,7 3,5 17,4 16,3 19,6 16,6 22,55 16,95 25,7 22,6 28,5 22, 32,7 22, 31,7 29,5 35,1 3,2 39,95 29,8 Below 5 F requires a factory of field installed low ambient control. Return air temperature F Page 9 of 12

This page intentionally left blank. Page 1 of 12

DIMENSIONS OF BASIC UNIT UNIT A B C D E F G H I J K L M N O P Q R WG3S2 31.63 87.5 33.38 28. 9.88 29.88 15.88 27.25 43.81 14.88 3 14.12 15.44 15.31 42.88 4.5 2.5 3. WG4S2/WG5S2 41.63 97.5 43.38 38. UNIT S T U V W X Y Z AA BB CC DD EE FF GG HH II WG3S2 3. 24.9 16 3.88 42 17.34 8.44 2.25 12.19 3.25 1 7.25 4.25 1.13 1.25 2..44 WG4S2/WG5S2 13. 34.9 W 4 DEG. PITCH IN TOP P 1 D DD FF GG HH II E EE 1 O B R F G CONDENSER AIR OUTLET VESTIBULE DOOR COMBUSTION AIR EXHAUST COMBUSTION AIR INTAKE FRONT DOOR FILTER SERVICE DOOR CONTROL PANEL DOOR N CIRCUIT BREAKER/ DISCONNECT ACCESS PANEL (LOCKABLE) VENT OPTION PANEL CONDENSER AIR INLETS A U I M Z L C J K H GAS ENTRANCES Q X AA LOW VOLTAGE ENTRANCES HIGH VOLTAGE Y ENTRANCES V CC SUPPLY OPENING BB B RETURN OPENING S S S S S FRONT RIGHT SIDE Optional top outlet in place of standard front supply opening, see Nomenclature outlet options (next page). Standard unit can also be field converted to this configuration using approved top supply outlet conversion kit shown on next page. FIGURE 1 COMBUSTIBLE CLEARANCE BACK T MIS-324 B Minimum Clearances Outlet Duct (from combustible materials) 1" first 3' Vent Terminal (from combustible materials) 17" Condenser Outlet 2" Top See Figure 1 Burner Service 2" Combustible Base (Wood or Class A, B or C roof covering material) " WARNING A minimum of one (1) inch clearance must be maintained between the supply air duct and combustible materials. This is required for the first three (3) feet of ducting. It is important to insure that the one (1) inch minimum spacing is maintained at all points. Failure to do this could result in overheating the combustible material and may result in a fire causing damage, injury or death. Page 11 of 12

Air Conditioning Wall-Mount Model Nomenclature MODEL NUMBER COOLING CAPACITY 3-3 Ton 4-4 Ton 5-5 Ton WG 3 S 2 A X B B X X X X X STEP CAPACITY SPECIALTY PRODUCTS (Non-Standard) C= Canadian Approval REVISION CODE VOLTS & PHASE A - 23/28-6-1 B - 23/28-6-3 C - 46-6-3 EMISSIONS X - Standard HEATING INPUT A = 5, B =, C = 1, D = 125,* VENT OPTIONS (See Table) FILTER OPTIONS X - 2-inch Pleated (MERV8) W - 1-inch Washable COLOR OPTIONS X - Beige (Standard) 4 - Buckeye Gray 8 - Dark Bronze CONTROL MODULES (See Table) COIL OPTIONS X - Standard 1 - Phenolic Coated Evap. 2 - Phenolic Coated Cond. 3 - Phenolic Coating on both coils OUTLET OPTIONS X - Front (Standard) T - Top Ventilation Options Models WG3S, WG4S, WG5S Description Factory Installed Field Installed Code No. Part No. Blank-Off Plate (Standard) B WGBOP-5 Commercial Ventilator - Spring Return w/exhaust V WGSCRVMP-5 Economizer (Internal) Fully Modulating w/exhaust E WGSJIFM-5 Energy Recovery Ventilator - 23 Volt w/exhaust R WGSERV-A5A-â Energy Recovery Ventilator - 46 Volt w/exhaust R WGSERV-C5A-â j Low ambient control is required with economizer for low temperature compressor operation. k Independent selection of intake and exhaust speeds (rate) with terminal block selection. â Color option must be specified to match unit ( X = Beige; 4 = Buckeye Gray; 8 = Dark Bronze) Top Supply Outlet Conversion Kits-Field Installed (Convert Standard Front Outlet to Top Outlet) USED WITH MODELS UNIT COLOR X - BEIGE UNIT COLOR 4 - BUCKEYE GRAY UNIT COLOR 8 - DARK BRONZE WG3S, WG4S, WG5S TSO-WG5-X TSO-WG5-4 TSO-WG5-8 Air Conditioning Control Modules (All Modules Except as Noted) HPC j LPC CCM LAC SK n Factory Installed Code Field Installed Code STD STD STD X N/A STD STD STD H CMA-28 STD STD STD Field Installed Only SK114 for WG3S2-A STD STD STD Field Installed Only SK111 for WG4S2-A STD STD STD Field Installed Only SK115 for WG5S2-A STD = Standard equipment for these specified models. HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note. LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note. CCM. Compressor control module has adjustable 3-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be 2-minutes plus 1% of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with 1 retry) for high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control. LAC. Low ambient control permits cooling operation down to F. SK. Start capacitor and potential relay start kit can be used with all -A single phase models. Increases starting torque 9x. Not used for -B or -C three phase models. Optional Field Installed Accessories DESCRIPTION PART NUMBER Natural Gas High Altitude Pressure Switch Kit (6-1, Feet) 862-189 Note: Natural Gas Orifice Change May Be Required Depending Upon Altitude and Gas BTU content. See Orifice and Altitude Tables. Propane Gas Conversion Kit ( - 6 Feet Altitude) WGCK-1 Propane Gas Conversion Kit (6-1, Feet Altitude) WGCK-2 Vertical Vent Kit (Includes all parts for 5 foot vertical vent) VVK-5A Additional 1 foot vertical vent pipe section for VVK-5A 862-21 Additional 2 foot vertical vent pipe section for VVK-5A 862-17 Additional 3 foot vertical vent pipe section for VVK-5A 862-2 Additional 5 foot vertical vent pipe section for VVK-5A 862-171 Page 12 of 12 Bard Manufacturing Company, Inc. Bryan, Ohio 4356 www.bardhvac.com Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S3396 May, 215