Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998

Similar documents
Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

Conductivity Sensors. Applications. 140 Series Conductivity Sensors Product Data Sheet LIQ_PDS_140_141_142_Conductivity_Sensors January 2014

Conductivity Sensors. Applications

ph/orp Sensor Model 399 ph/orp

NEW QUICK CABLE-TO-SENSOR RELEASE,

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

Instruction Manual PN /rev.C June Models 140, 141, 142. Conductivity Sensor Assemblies

For additional information, please visit our website at SENSOR SPECIFICATIONS

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

Insertion/Submersion Flow Through Sensor

ENDURANCE Conductivity Sensors

ENDURANCE. Sanitary Flange Conductivity Sensors. Models 403 and 403VP. Product Data Sheet PDS /rev.A June 2005

Toroidal Conductivity Sensor

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

Rosemount 402 and 402VP

TUpH Retraction/Submersion/Insertion ph/orp Sensors

Rosemount 228. Toroidal Conductivity Sensor. Product Data Sheet July Series LIQ-PDS-228

General Purpose Toroidal Conductivity Sensors

Liquid Conductivity Two & Four Electrode Sensors

General Purpose ph/orp Sensors

Rosemount TM 222 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-222 Rev.D June 2017

General Purpose ph/orp Sensors

Endurance TM Conductivity Sensors

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen, ph, and Conductivity

Analytical Instruments Two-Electrode Conductivity Sensors

Retractable ph/orp Sensors

Model 385+ Instruction Manual PN February ph/orp Sensor

Pasve Rotary Retraction Valve

Signet Conductivity/Resistivity Electrodes

Rosemount TM 242 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-242 Rev. F June 2017

Retractable ph/orp Sensors

Retractable ph/orp Sensors

Accessories Guide ph/orp/conductivity Sensors

Retractable ph/orp Sensors

Instruction Manual PN /rev.H March Model 385+ ph/orp Sensor

PRO-II SERIES SAND MEDIA FILTRATION SYSTEMS Kits and Parts Listing

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP

PN October Liquid Division. Mounting Solutions

COMBINATION ph SENSOR

Triple Junction ph/orp Sensor

Model Instruction Manual P/N January Conductivity Sensors

Signet Conductivity/Resistivity Electrodes

3D TRASAR Automation - Boiler Blowdown Equipment

Combination ph/orp Sensor

Combination ph/orp Sensor

Instruction Manual PN /rev.C May Model 242. Flow-Through Toroidal Conductivity Sensor

SIGNET 2760 DryLoc ph/orp Preamplifier

PN /rev. B April Liquid Division. Mounting Solutions

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

Combination ph/redox (ORP) Sensors

Instruction Manual PN /rev.D September 2009 Model 385. Retractable ph/orp Sensor

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB4CS 4-electrode conductivity sensor

Model 6330 COSASCO Retractable System Injection/Sampling Tube Assemblies

Analytical Instruments Four-Electrode Conductivity Sensors for Process Monitoring Model TB4

Series Regulators - Pressure Reducing

SST Series Sand Media Filtration Systems

SAMPLE CYLINDERS. Sample Cylinders & Accessories. Spun End Cylinders. Ultra-Seal Constant Pressure Cylinders. VP Series Cylinder Valves

Combination ph/redox (ORP) Sensors

General Specifications

TB4CS Conductivity sensor 4-Electrode. Low maintenance sensor with the widest operation range available (0 to 2000 ms/cm)

Sample Probe Module. Application Guide

4909 CPVC Conductivity Cell Insertion/Removal Assembly Operations Manual Rev. 1 7/99

Model DFLP Linear Actuator

Differential Pressure Gauges Magnetic-Piston Sensing Element with Diaphragm Type

Differential Pressure Gauges Magnetic-Piston Sensing Element with Diaphragm Type

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller

Signet 2760 DryLoc ph/orp Preamplifier

Signet V(D) to V(D) PVDF Conductivity Electrodes

4-ELECTRODE CONDUCTIVITY SENSORS

Conductivity. Inductive Conductivity Sensors. Features and Benefits DATA SHEET. Wide Measuring Range. Low-maintenance Design. Complete Digital System

Instruction Manual PN /rev.G March 2012 Model 381+ ph/orp Sensor

Model Q45H/ Residual Chlorine Monitor...

OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS

Electromagnetic Flow Monitor magphant

2-ELECTRODE CONDUCTIVITY SENSORS

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 122

Rosemount 3051S Electronic Remote Sensor (ERS) System

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

2" ROTARY VALVE 8-WAY ACTUATOR RSV SERIES. Valve body not included. Electronic Control Type:

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

PRODUCT IDENTIFICATION & COMPANY

Bourdon Tube Pressure Switches

Baumann Pneumatic Pressure Controller (for Industrial and Sanitary Applications)

Information Sheet Polyethylene Tank Assemblies

ENGINEERED LIQUID LEVEL SOLUTIONS DURABILITY AND DEPENDABILITY FLAT GLASS GAUGES & VALVES FOR PROCESS LEVEL MEASUREMENT BY KENCO

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

Triple Junction Sensor

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

PRESSURE BENCH OPERATING INSTRUCTIONS

Rosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP

Seismic Sensor Accessories SA, SV & ST 6000 Series

Welker Probe Instrument Regulator with Liquid Eliminator Cartridge

KEL DIFFERENTIAL PRESSURE FLOWMETERS

Connectors & Connectors with valves

Transcription:

Product Data Sheet 71-140 series/rev.a June 1998 Model 140, 141, 142 Conductivity Sensors HIGH TEMPERATURE 316 SS AND PEEK CON- STRUCTION operates up to 200 C (392 F). MODEL 140 RETRACTABLE SENSOR installs through a one inch ball valve. INCLUDES ALL INSTALLATION HARDWARE. RUGGED CAST ALUMINUM WEATHER PROOF JUNCTION BOX provides easy access to field wiring. MEASUREMENT RANGES FROM 0-1 µs/cm to 0-20,000 µs/cm. FEATURES AND APPLICATIONS The Rosemount Analytical Models 140, 141, and 142 conductivity sensors are designed for measuring conductivity in high temperature and pressure applications. A choice of cell constants allows measurements in low to medium conductivity level samples. Corrosion-resistant 316 stainless steel construction and the ability to be inserted directly into a process line or through the side of a vessel make the sensors rugged and easy to install. The Model 140 retractable conductivity sensor simplifies sensor installation and maintenance because it can be removed from a pressurized line or vessel without shutting down the process or using bypass sample lines. The sensor s measuring electrodes are inserted into the process through a 1 in. ball valve and a Viton 1 process seal. To retract the sensor, a retaining nut is loosened, the sensor backed out of the process and the ball valve closed. The standard Model 140 is constructed of 316 stainless steel and PEEK and can operate at up to 150 C. High temperature options (Codes 05, 07, 55, or 57) must be selected to measure up to 200 C. The choice of a 0.2 or 1.0 cell constant allows conductivity measurements up to 20,000 µs/cm with the Rosemount Analytical Models 54C,1054A/B C, 2054C, 1181C, 2081C, 3081C, and 81C analyzers. The Model 141 insertion sensor measures conductivity in high temperature, high pressure applications. The standard Model 141 is constructed of 316 stainless steel and PEEK and can operate at temperatures up to 150 C. An optional high temperature version (Code 14) can operate at temperatures up to 200 C. The choice of a 0.2 or 1.0 cell constant allows conductivity measurements up to 20,000 µs/cm with the Rosemount Analytical Models 54C, 1054A/B C, 2054C, 1181C, 2081C, 3081C, and the 81C analyzers. Continued on page 2

Continued from page 1 The Model 142 low conductivity insertion sensor measures low conductivity solutions at high temperatures and pressures. The standard Model 142 is constructed of 316 stainless steel and Kel-F, and can operate at temperatures up to 150 C. An optional high temperature version (Code 14) can operate at temperatures up to 200 C and is constructed of 316 stainless steel and PEEK. The choice of a 0.01 or 0.1 cell constant allows measurement ranges from 0-1 µs/cm and up to 0-2,000 µs/cm with the Rosemount Analytical Models 54C, 1054A/B C, 1181C, 2081C, 3081C, and 81C analyzers. 1 A registered trademark of E. I. du Pont de Nemours and Company 2 A registered trademark of 3M Company. 3/4 IN FPT TO ANALYZER 460.5 18.13 3/4 IN X 3/4 IN NPT MALE CONNECTOR 127 5 J-BOX MILLIMETER INCH HEX NUTS 1 IN X 3/4 IN NPT REDUCING BUSHING 1 IN NPT BALL VALVE 1 INCH MPT 127 5 PROBE VENT HOLE 4 PLACES APPLY ONLY TO 1.0 CON- STANT MODEL 140 Mounting Dimensions PROCESS PIPING VALVE HANDLE SENSOR WELDALET A to be one inch or greater from vessel wall MODEL 140 Mounting Configuration 2 Rosemount Analytical

FLOW MILLIMETER INCH 127.0 5.0 SENSOR 92 3-5/8 TEE 38 1-1/2 PROBE 3/4 INCH FPT TO INSTRUMENT 29 1-1/8 3/4 INCH NPT FLOW MODEL 141 Mounting Dimensions MILLIMETER INCH 127.0 5.0 3/4 INCH FPT TO INSTRUMENT HEX NUTS 308 12-1/8 3/4 IN. X 3/4 IN. NPT MALE CONNECTORS 3/4 INCH MPT 127 5 1/4 INCH VENT HOLE (4 PLCS) 19.5 3/4 DIA MODEL 142 Mounting Dimensions 3 Rosemount Analytical

SENSOR SPECIFICATIONS SPECIFICATIONS MODEL 140 MODEL 141 MODEL 142 Cell Constant 0.2 and 1.0/cm 0.2 and 1.0/cm 0.01 and 01/cm Standard: 150 C (302 F) Standard: 150 C (302 F) Standard: 150 C (302 F) Maximum up to 250 psig (1825 kpa abs) up to 250 psig (1825 kpa abs) Temperature High Temp: 200 C (392 F) High Temp: 200 C (392 F) High Temp: 200 C (392 F) up to 250 psig (1825 kpa abs) up to 250 psig (1825 kpa abs) Maximum Pressure 100 psig (791 kpa) See Figure 1 See Figure 1 Codes 04, 06, 54, 56: 0-150 C Standard: 0-150 C Standard: 0-150 C Temperature (32-302 F) (32-302 F) (32-302 F) Compensation Codes 05, 07, 55, 57: to 200 C High Temp: to 200 C High Temp: to 200 C (to 392 F) (to 392 F) (to 392 F) WETTED MATERIALS Electrodes 316 Stainless Steel. 316 Stainless Steel. 316 Stainless Steel. Insulators PEEK PEEK Kel-F for standard temp. PEEK for high temperature O-Rings Viton Viton Viton Sensor Body 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel Junction Box Cast Aluminum Cast Aluminum Cast Aluminum Weight/Ship Weight 5 lb/6 lb (2.26/2.72 kg) 2 lb/3 lb (0.9/1.4 kg) 4 lb/5 lb (1.9/2.3 kg) FIGURE 1. MODELS 141 and 142 Maximum Pressure Rosemount Analytical 4

ORDERING INFORMATION The Model 140 Retractable Conductivity Sensor: Designed for insertion through a 1 in. ball valve. Materials of construction include 316 SS electrodes with PEEK insulator for service up to 200 C. Standard features include a cast aluminum NEMA 7D junction box and a choice of cell constants of either 0.2 or 1.0. The cable and ball valve must be ordered separately. MODEL 140 RETRACTABLE CONDUCTIVITY SENSOR CODE GROUP I FOR USE WITH MODEL 1181C (Required Selection - one only from Group I or II) 04 0.2/cm cell constant *05* 0.2/cm cell constant, high temperature construction 06 1.0/cm cell constant *07* 1.0/cm cell constant, high temperature construction CODE GROUP II FOR USE WITH MODELS 54C, 1054A/B C, 2054C, 2081C, 3081C & 81C 54 0.2/cm cell constant 55 0.2/cm cell constant, high temperature construction 56 1.0/cm cell constant 57 1.0/cm cell constant, high temperature construction 140 54 EXAMPLE * Model 1181 C must be supplied with 100 to 200 C temperature compensation range (option -09). NOTE: Ball valve kit, P/N 23724-00, is ordered as a separate item. ACCESSORIES for Models 140, 141, and 142 P/N DESCRIPTION 23724-00 Ball valve kit, 316 stainless steel (for Model 140 sensors) 9200104 Cable, 8 conductor, 24 AWG, 4 shielded pair (1181C) 9200266 Cable, 9 conductor (1054A/B C, 2054C, 2081C, 3081C, 54C, and 81C) 9200275 Cable, 5 conductor, shielded (unprepped) 23747-00 Cable, 5 conductor, shielded (prepped) SS-3 Conductivity standard, 2000 µs/cm, 1 qt SS-6 Conductivity standard, 200 µs/cm, 1 qt 23731-00 Process fitting rebuild kit (for Model 140 sensors) 23730-00 Process compression fitting (3/4-in. NPT) kit (for Model 140 sensors) 9310120 Junction box compression fitting (for Model 140 sensors) 9550200 O-ring, 2-116, Viton (for Model 140 sensors) 3001882 Process compression fitting, 3/4-in. NPT (for Model 142 sensors) 5 Rosemount Analytical

ORDERING INFORMATION The Model 141/142 Insertion Conductivity Sensors: Designed for high pressure, high temperature service. The Model 141 Sensor cell constants of 0.2 and 1.0 are suitable for measurements up to 20,000 µs/cm. The Model 142 Sensor cell constants of 0.1 and 0.01 provide conductivity measurements down to 1 µs/cm full scale. The standard -13 sensors are constructed to operate up to 150 C. To operate up to 200 C, the high temperature option (Code 14) must be selected. The sensors do not come with interconnecting cable. See previous page for cable requirements. MODEL 141/142 INSERTION CONDUCTIVITY SENSOR CODE CELL CONSTANT (Required Selection) 01* 0.01/cm (Model 142 only) 03 0.1/cm (Model 142 only) 04 0.2/cm (Model 141 only) 06 1.0/cm (Model 141 only) CODE TEMPERATURE (Required Selection) 13 Standard construction for operation up to 150 C *14** High temperature construction for operation between 100 C and 200 C 54 For use with Models 54C, 1054A/B C, 2054C, 2081C, 3081C & 81C 141 06 13 54 EXAMPLE * Recommended for use with the Models 3081C and 81C for best accuracy at low conductivity ** Model 1181C must be supplied with 100 to 200 C temperature compensation range (option -09). The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Credit Cards for U.S. Purchases Only. Emerson Process Management Rosemount Analytical Inc. 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2002