Emergency lighting units EM LED Light Engines. Module EM-ES 08/10/12 Mk2 EM LED linear / area

Similar documents
LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC EM STARK LLE

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

LED modules LED linear / area

LED light engine / OLED LED linear / area

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE , CLE CLASSIC Modules CLE

LED light engine / OLED LED linear / area. Module STARK LLE PREMIUM Modules LLE

LED light engine / OLED LED compact. Umodule EOS P214-4 umodule EOS

PHASED OUT. LED light engine / OLED LED compact. Module STARK CLE CLASSIC / CLE CLASSIC Modules CLE

PHASED OUT. LED / OLED Light Engine LED linear / area. Umodule STARK LLE STARK LLE

LED light engine / OLED LED compact

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK LLE umodule LLE ADVANCED

LED light engine / OLED LED linear / area. Umodule STARK LLE-G CLASSIC STARK LLE

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

LED light engines LED linear / area

LED modules LED flexible. Module LLE FLEX G1 8mm EXC Modules LLE FLEX EXCITE

Tunable White LED linear / area. Module LLE G2 PREMIUM LLE PREMIUM

LED modules LED linear / area

PHASED OUT. LED light engine / OLED LED compact. Module SLE G5 ART EXC Modules SLE EXCITE

PHASED OUT. LED light engine / OLED LED compact. Umodule STARK DLE GEN2 CLASSIC STARK DLE

LED light engine / OLED LED compact. Umodule SLE G4 FASHION EXC

LED light engines LED linear / area

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule STARK QLE CLASSIC EM umodule STARK QLE PHASED OUT. Ordering data.

LED light engines LED linear / area

LED light engines LED linear / area

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

LED light engines LED linear / area

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

Tunable White LED linear / area

LED modules LED linear / area

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Emergency lighting units EM powerled

Emergency lighting units EM LED Light Engines

Emergency lighting units EM powerled

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM powerled

Emergency lighting units LED series

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Uengine COOL door for integration uengine COOL

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM powerled

LED BUILT-IN MODULES. LED Module Easy 28 Industrial and Hospitality Lighting EASY 28 3,500 LM TO 14,000 LM EASY 28 INDUSTRIAL AND HOSPITALITY LIGHTING

Emergency lighting units EM converterled

LED LINE SMD KIT GEN. 2

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

LED BUILT-IN MODULES. LUGA C 2016 HiCRI COB modules for lumen packages from 1500 to 4500 lm. LUGA C 2016 HiCRI 1500 LM TO 4500 LM.

Emergency lighting units EM converterled

LED MODULES. Comfort COB Residential, Retail and Industrial Lighting COMFORT COB 500 LM TO 11,000 LM

Emergency lighting units EM converterled

LED Driver Linear / area dimming

U LED modules, converters and systems SIGNAGE. Uengine IMAGE SELECT

Emergency lighting units EM powerled

Emergency lighting units PC COMBO

LED control gear Compact fixed output

Emergency lighting units EM powerled

Emergency lighting units EM Inverter

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Description: RX-ALF28T Series Waterproof LED module, Ultra-Slim Light Box direct type light source - can be continuously

LED Driver Compact fixed output

LED Driver Compact fixed output

Datasheet. Oslon10 Cluster White. LED Solutions. ILR-ON10-xxxx-SC201-xx series. Product Overview. Applications. Technical Features:

Stanley 3J 1 PowerStar Whites

Emergency lighting units EM INVERTER

Emergency lighting units PC COMBO

BUILT-IN LED LIGHTING MODULES

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

DATA SHEET. GLV92C50501 Series. Part of the simpleled Program v1 P-1

LEDtape 800 TW Tunable White K CRI>90

Applications. General Lighting Office Lighting Food Lighting Accent Lighting. Electrical Properties

LED DOWNLIGHTS. Prime K L LED Downlights with Separate LED Driver HIGH QUALITY COB TECHNOLOGY LED DOWNLIGHTS WITH SEPARATE LED DRIVER

LED MODULES. LUGA Shop Gen. 5 Retail and Industrial Lighting LUGA SHOP GEN LM TO 20,000 LM LUGA SHOP GEN. 5 RETAIL AND INDUSTRIAL LIGHTING

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number

PRODUCT DESCRIPTION TECHNICAL DATA. Dimmable 0.1% - 100% Operating temperature - 30 C +45 C LED per meter 60 Pitch distance Cutting Length (C)

Duris E5 PowerFlex LED Strips 7.5mm LED Pitch

OSLON 9 PowerCluster IR

LED DOWNLIGHTS. Prime K L LED Downlights HIGH QUALITY COB TECHNOLOGY LED-DOWNLIGHTS

Transcription:

X1 X1 DC1 DC1 D81 D82 D83 D84 D85 D86 DC2 AK AK AK D121 D101 D81 D122 D102 D123 D82 D103 D124 D83 D125 D126 D84 D127 D106 D85 D128 D107 D129 D86 D108 D1210 DC2 AK AK AK D104 D105 Emergency lighting units Module EM-ES 08/10/12 Mk2 EM LED linear / area Lighting module with 8, 10 or 12 LEDs For use in escape route signs Compatible with EM powerled 1 W & 2 W Properties Suitable for Tridonic EM powerled emergency lighting units For permanent and standby operation Wide 120 distribution of light for uniform illumination Operation on a constant current source Replacement for 8 W T5 flourescent lamp Several options for uniform light distribution Can be interconnected to create longer strips Low energy consumption 15,8 Long life thanks to low operating temperature Provides a maintenance-free escape sign system 97 97 Simple mounting/installation 245 Push-in terminals for simple and quick wiring Note Separate status LED required 15,8 Technische Daten Ambient temperature ta 3-30... +55 C Typ. tc point 4 60 C Typ.luminous flux at 25 C 13 130 lm Max. forward current 2 600 ma Min. forward voltage 1 2.7 V Typ. forward voltage at 25 C 1 3.0 V Max. forward voltage 1 3.2 V Typ. power 13 1.05 W Colour rendering index CRI 80 Beam characteristic 120 Risk group (EN 62471:2008) 0 Type of protection IP00 Type Article number Colour 107 107 285 Colour temperature pallet Weight per pc. 8 light points per module ES 08 246 Mk2 89800249 Daylight white 6,500 K 25 pc(s). 600 pc(s). 0.014 kg ES 08 285 Mk2 89800250 Daylight white 6,500 K 25 pc(s). 600 pc(s). 0.016 kg 10 light points per module ES 10 285 Mk2 89800251 Daylight white 6,500 K 25 pc(s). 600 pc(s). 0.017 kg 12 light points per module ES 12 285 Mk2 89800248 Daylight white 6,500 K 25 pc(s). 600 pc(s). 0.018 kg È Standards, page 3 www.tridonic.com 1

Specific technical data Typ Article number Total length Hole spacing D ES 08 246 Mk2 89800249 245 mm 97 mm ES 08 285 Mk2 89800250 285 mm 107 mm ES 10 285 Mk2 89800251 285 mm 107 mm ES 12 285 Mk2 89800248 285 mm 107 mm 1 Tolerance range for optical and electrical data: ±15 % 2 Exceeding the max. operating current leads to an overload on the LED module. This may in turn result in a significant reduction in life-time or even destruction of the LED module. 3 Data for operation with 350 ma. 4 If the max. temperature limits are exceeded, the life of the module will be reduced or the module may be damaged. The temperature of the LED module at the tc-point is to be measured in the thermally stable state. For tc-point see the above diagram. ACCES- SORIES Status indication green LED A green LED indicates that charging current is flowing into the battery Type Article number bag Weight per pc. LED EM green 89899605 25 pc(s). 200 pc(s). 0.017 kg LED EM green, high brightness 89899756 25 pc(s). 200 pc(s). 0.012 kg www.tridonic.com 2

ACCES- SORIES Status indication bi-colour LED Two-colour status display LED Green: system OK, red: fault Type Article number bag Weight per pc. LED EM bi-colour 89899720 25 pc(s). 200 pc(s). 0.017 kg LED EM bi-colour, high brightness 89899753 25 pc(s). 200pc(s). 0.013 kg www.tridonic.com 3

Thermal design and heat sink The rated life of LED products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the EM-ES will be greatly reduced or the EM-ES may be destroyed. tc point, ambient temperature and life-time The temperature at tp reference point is crucial for the light output and life-time of a LED product. EM-ES Mk2 tp temperature L90 / B10 L90 / B50 L80 / B10 L80 / B50 L70 / B10 L70 / B50 60 C 50,000 h 50,000 h 50,000 h 50,000 h 50,000 h 50,000 h 57 C 50,000 h x x x x x Operating unit EM powerled 1 2 W (see separate data sheet) Precautions in Handling Safety Precautions The LED light output is intense enough to cause injury to human eyes if viewed directly. Precautions must be taken to avoid looking directly at the LEDs with unprotected eyes [according IEC 60825-1 (EN 60825-1)]. The EM-ES are delivered in an ESD protected packaging. Precaution in driving Products are designed exclusively for forward current driving. Please avoid driving system with reverse voltage, which may cause migration which damages the product. Reverse polarity and secondary ing can damage the LED module. Cleaning Chemical solvents or cleaning agents must not be used to clean the LED component. Mechanical stress on the LED component must be avoided. It is best to use a soft brush, damp cloth or low-pressure compressed air. Storage The products should be stored away from direct light in dry location. The LEDs should be kept at 30 C or less and 70 % RH or less. Please avoid rapid transitions in ambient temperature, especially in high humidity environments where condensation could occur. Mounting instruction Wiring type and cross section The wiring can be solid cable with a cross section of 0.2 to 0.75 mm². For the push-wire connection you have to strip the insulation (6 7 mm). wire preparation: 0.2 0.75 mm² 6 7 mm Inserting stranded wires / removing wires by lightly pressing on the push button. Standards EN 62031 EN 62471 Chemical substance may harm the LED module. Chemical reactions could lead to colour shift, reduced luminous flux or a total failure of the module caused by corrosion of electrical connections. Materials which are used in LED applications (e.g. sealings, adhesives) must not produce dissolver gas. They must not be condensation curing based, acetate curing based or contain sulfur, chlorine or phthalate. Avoid corrosive atmosphere during usage and storage. EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp Precautions for safe operation The operating unit must be SELV classified or else the circuit board must be insulated by the luminaire. i For further technical information particulary with regard to the installation of LED modules please refer to www.tridonic.com None of the components of the EM-ES (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. Max. torque for fixing: 0.5 Nm. The LED modules are mounted with 4 screws per module. In order not to damage the modules only rounded head screws and an additional plastic flat washer should be used. Fixing can be achieved using M4 plastic screws or M4 plastic rivets through the holes provided or alternatively by appropriate adhesive pads positioned in the fixing areas. www.tridonic.com 4

Wiring example for one LED strip Line in from Neutral Permanent line SL N L EM powerled status A status K LED + LED Bat Bat + orange pink LED Optional Test Switch Battery The LED on the strip are connected in parallel. The LED current through the single LED varies slightly dependent on the characteristics of the LED. Wiring example for two LED strips connected in series Line in from Neutral Permanent line SL N L EM powerled status A status K LED + LED Bat Bat + orange pink LED Optional Test Switch Maximum two LED strips can be connected in series to the constant current emergency converter EM powerled Battery Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. www.tridonic.com 5