Jandy Pro Series NeverLube and Backwash Valve

Similar documents
Jandy Pro Series Water Feature Pump Model WFTR INSTALLATION AND OPERATION MANUAL WARNING ENGLISH

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Zodiac VS FloPro Variable-Speed Pump Series E3 INSTALLATION AND OPERATION MANUAL WARNING ENGLISH

Installation and Operation Manual. FloPro Series Pumps WARNING. Model FHPM

AquaPure Ei TM Series Replacement Kits

Jandy FloPro (FHP) Series Pump Parts Replacement Kit Instructions

Installation and Operation Manual. Jandy Diatomaceous Earth Pool Fil ters. DEV Series Fil ters

OWNER S MANUAL D.E. CARTRIDGE. Installation Operation Parts. Models PCDE-30 PCDE-40

INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N )

INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR

WARNING FOR YOUR SAFETY:

Installation and Operation Manual. Jandy Single Element Cartridge Pool and Spa Filters. CS Series Filters

WARNING FOR YOUR SAFETY:

WARNING FOR YOUR SAFETY:

TRIMLINE CARTRIDGE FILTERS

Installation and Operation Manual Stealth Series Pumps (Models JHP & JHPU) WARNING

M A I N T E N A N C E G U I D E V A L V E I N S T A L L A T I O N A N D IMPORTANT INFORMATION SERIAL NUMBER

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Installation and Operation Manual. Jandy Cartridge Pool/Spa Filters. Models CJ200 and CJ250

Filter Parts. CV Series Cartridge Filter Part #CV340, CV460, CV ZODIAC POOL SYSTEMS CATALOG 51. Filter Parts 1,6 13, 21 12,11 18, 21 15, 21

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

COMMERCIAL MULTIPORT VALVES

Installation and Operation Manual. Stealth WaterFall Series Pumps WARNING. Model SWF

Sand Filtration System

TRIMLINE CARTRIDGE FILTERS

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

MagicStream Laminar. Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

Wahoo Limited Warranty

QL 420 / 540 CARTRIDGE FILTER

DIVERTER AND CHECK VALVES 1-1/2 IN. AND 2 IN. 2-WAY, 3-WAY AND CHECK

ACF Operation Manual

DIVERTER AND CHECK VALVES 1-1/2 IN. AND 2 IN. 2-WAY, 3-WAY AND CHECK

GL Ludemann Y-Strainers

Installation / Operation Manual

HIGH RATE SAND FILTERS

INSTALLATION AND OPERATING INSTRUCTIONS. EXP Hurlcon Pumps CTX Series & BX Series. Bolero ND Cleaner

THS SERIES FILTER BUTTERFLY VALVE STYLE FACE PIPING

Owners Guide Built-in pool cleaning and circulation systems

Heater Manifold REPLACEMENT INSTRUCTIONS. Sta-Rite Pool/Spa Group. 293 Wright Street, Delavan, WI 53115

WARNING. Important Notice

VALVE PARTS VALVE PARTS

SUBMERSIBLE SWIMMING POOL DRAINER

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

JPS VARIABLE SPEED PUMPS INSTALLATION/PROGRAMMING/ AFFINITY LAW

Pressurized Bead Filters

Meteor Filter System Kit Owner's Manual

SUBMERSIBLE MINI-PUMP

6 and 8 HAIR AND LINT STRAINERS

Installation Guidelines

Manual for 12 Sand Filter/ Pump Combo Unit.

SUPPLEMENTAL MANUAL FOR THE INSTALLATION, OPERATION AND MAINTENANCE OF THE XL234 FILTER VESSEL

2-Speed Pumps Item #s 7813, 7814, 7818 & 7819

SMBW 4000 Series Filter Operating Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS.

Operating instructions Form no safety definitions

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG

VALVE PARTS. Valve Parts

Product Manual PS3900 / PS4600 / PS7000 / PS15000 / BF1600 / BF1900 / BF2600 / BF

OPERATION MANUAL VCX-1

Installation, Operation & Maintenance Manual

HARMSCO Filtration Products BC6 Series

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

SAND FILTERS. Models: ECSF500, ECSF650, ECSF700, & ECSF800

To ensure proper installation, digital pictures with contact information to before startup.

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Low Profile J Series Power Unit with Vane Pump

ESE Series Cast Iron Sewage Pumps

AUTOMATIC POOL CLEANER INSTALLATION MANUAL.

PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM

Firehawk Second Stage Regulator Fire Service

Owners Manual: - Pumps

#71225 SAND FILTER & PUMP. TOOLS REQUIRED Phillips Screwdriver Flat Head Screwdriver O-Ring Lube

Aboveground Systems Mounting Base Installation Instructions

Installation, Operating, and Service Manual. Badu. EcoM3 V. Variable Speed Pool Pump

QuickServe Online ( ) ISB6.7 CM2350 B101 Service Manual

Regulated Hose Supply Installation, Operation & Maintenance Manual

IntelliChlor Electronic Chlorine Generator Commercial System COMSYS

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

HALLMARK INDUSTRIES INC

THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP

PRE-PLUMBED SEWAGE SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS

Clean & Clear Filter System Owner's Manual. Important Notice WARNING

PRODUCT OPERATING MANUAL

FULFLO CARTRIDGE FILTERS

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

IntelliTouch Pool and Spa Control System Load Center and Power Center

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

AquaLuminator Light and Return Water Flow for Above Ground Pools Owner's Manual

INSTALLATION & OPERATION MANUAL

G1000 Feeder IMPORTANT INFORMATION

GARDEN HOSE UTILITY PUMP

Artesian2 Owners Manual

Posi Clear TM Cartridge Filters Models PXC75, PXC95, PXC125 and PXC150

OWNER S MANUAL - BX and CTX PUMPS

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

DATA SHEET 6K151CT2, 6K151CT4, 6K201CT2, 6K201CT4, 6K301CT4, 6K401CT4 OPEN IMPELLER CENTRIFUGAL PUMPS. Stainless Steel Models: SPECIFICATIONS FEATURES

THS SERIES FILTER OWNER S/OPERATOR S MANUAL TANKS ONLY

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Transcription:

installation and Operation Manual English Jandy Pro Series NeverLube and Backwash Valve FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty. Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death. H0551800 Rev G ATTENTION INSTALLER - This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/ operator of this equipment.

Page 2 ENGLISH Jandy Pro Series, NeverLube Backwash Valve Installation & Operation Manual

Jandy Pro Series, NeverLube Backwash Valve Installation & Operation Manual ENGLISH Page 3 Table of Contents Section 1. Safety Information... 4 Section 2. DE and Sand Filters... 5 Section 3. Versa-Coupler Installation... 7 Section 4. Normal Operation... 7 Section 5. Backwashing... 7 Section 6. Vacuuming to Waste (Optional)... 8 Section 7. Replacement Parts List... 10

Page 4 ENGLISH Jandy Pro Series, NeverLube Backwash Valve Installation & Operation Manual Section 1. Safety Information FOR YOUR SAFETY: This product must be installed and serviced by a professional pool/spa service technician. The procedures in this instruction sheet must be followed exactly. Improper installation and/or operation will void the warranty. Ensure that all electrical power to the system is turned off before approaching, inspecting or troubleshooting any leaking valves that may have caused other electrical devices in the surrounding area to get wet. Failure to do so could result in an electrical hazard that could result in death or serious injury due to electrical shock, and may also cause damage to property and/or operation. Do not connect system to an unregulated city water system or other external source of pressurized water producing pressures greater than 35 PSI. Pressurized air in system can cause product failure or also cause the filter lid to be blown off which can result in death, serious personal injury, or property damage. Be sure all air is out of system before operating or testing the equipment. To minimize risk of severe injury or death the filter and/or pump should not be subjected to the piping system pressurization test. Local codes may require the pool piping system to be subjected to a pressure test. These requirements are generally not intended to apply to the pool equipment such as filters or pumps. Jandy Pro Series pool equipment is pressure tested at the factory. If however this cannot be followed and pressure testing of the piping system must include the filter and/or pump BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS: Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and secured before testing. RELEASE ALL AIR in the system before testing. Water pressure for test must NOT EXCEED 35 PSI. Water temperature for test must NOT EXCEED 100 F (38 C). Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. Notice: These parameters apply to Jandy Pro Series equipment only. For non-jandy equipment, consult equipment manufacturer. READ AND FOLLOW ALL INSTRUCTIONS

Jandy Pro Series, NeverLube Backwash Valve Installation & Operation Manual ENGLISH Page 5 This document gives instructions for installing a Jandy Pro Series NeverLube Backwash Valve. The instructions must be followed exactly. Read through the instructions completely before starting the procedure. Please save these instructions. The Jandy Pro Series 2-in-1 NeverLube backwash valve is designed to be used on either sand or diatomaceous earth (DE) filters with a center-to-center dimension of 8 inches (center of the inlet port to the center of the outlet port). Used with the Jandy Pro Series versa-coupler, the NeverLube backwash valve can be used on filters with center-to-center dimensions of 7 to 9 inches. For Jandy Pro Series Filters, NeverLube backwash valve p/n 8034J comes ready to mount to DEL48 or DEL60 model filters (outlet being the top port). If using the 8034J with another model sand or DE filter, install per label on valve. BWVL-NVL mounts to DEV48, DEV60, or JS series filters. For Pentair or Sta-Rite filters, a combination of p/n 8034 (NeverLube backwash valve) with p/n 8044 (Versa-Coupler Kit) can be used to mount to most models. To mount on a sand filter from a manufacturer other than Jandy Pro Series (with the inlet being the top port), simply flip the valve over. If the valve handle ends up on the bottom of the valve, remove the locking knob and handle and place on the top. Hand tighten the locking knob. See Figure 1. Section 2. DE and Sand Filters 1. Turn the locking knob on the NeverLube backwash valve counter clockwise to loosen. Turn the handle back and forth several times to verify the diverters move freely. 2. Turn off all power to the system. For retrofit installations only, follow steps "a" through "d". For new installations skip steps "a" through "d" and proceed to step 3. a. Open the pressure relief valve on top of the filter. Wait for all air to evacuate the system. Never attempt to assemble, disassemble or adjust the filter when there is pressurized air in the system. Starting the pump while there is any pressurized air in the system can cause the filter lid to be blown off, which can cause death, serious personal injury or property damage. b. If the filter is below pool level, close the suction and return line valves to isolate the filtration system. c. Remove the drain plug from the filter. Let the water drain from the filter. d. Remove the existing valve from the filter. DE Filter Setup To Filter Body (cut away view) Sand Filter Setup To Filter Body (cut away view) Waste Port to Top 3. Remove the NeverLube backwash valve from packaging. 4. Remove the two (2) O-rings from packaging. 5. Place O-rings on the face of the union tail pieces, where the face of the NeverLube backwash valve union will connect to the filter bulkheads. See Figure 2. Make sure each O-ring is properly seated into the groove of each union tail piece. 6. Holding the valve upright, place onto the filter bulkheads. Waste Port to Bottom Union Nuts Figure 1. Handle Positions (DE and Sand)

Page 6 ENGLISH Jandy Pro Series, NeverLube Backwash Valve Installation & Operation Manual Coupling Nut Union Tail Piece O-ring Face of Pors Figure 2. O-ring Placement CAUTION The NeverLube backwash valve has molded labels on each port. Please note when installing the NeverLube backwash valve on sand or DE filters, ensure that the valve ports coincide with the corresponding filter ports. Alignment Mark Jandy Pro Series DEL, DEV or JS Series Filter Setup Shown To Filter Body (cut away view) Versa-Coupler p/n 8044 To Pool Figure 4. Jandy Versa-Coupler Figure 3. From Pump Couplers To Waste 10. Plumb the discharge of the pump into the NeverLube backwash valve inlet labeled FROM PUMP. 11. Plumb the NeverLube backwash valve outlet labeled POOL RETURN to the heater or pool return lines. 12. Plumb the WASTE ports as needed. Let the system dry for 24 hours. 13. When the glue is dry, start the system and check for proper water flow. CAUTION Do not let any adhesive get inside the valve body. Excessive adhesive inside the valve body will prevent the diverter from moving freely. 7. Tighten both union nuts to secure the valve on the filter. 8. If the valve handle is on the bottom of the valve, remove the locking knob and handle and move to the top. Hand tighten the locking knob. 9. Place filter and valve in proper location on the equipment set pad. NOTE: For new installations other than Jandy Pro Series DEL, DEV, or JS series, use the NeverLube backwash valve (p/n 8034) and Versa Coupler Kit (p/n 8044). If using the NeverLube backwash valve with a Pentair filter, use Pentair Pool Products Union Set #27002, and then proceed to Section 2. If using a Sta-Rite filter, use Sta-Rite Union Set #PKGM188, then proceed to Section 2.

Jandy Pro Series, NeverLube Backwash Valve Installation & Operation Manual ENGLISH Page 7 Section 3. Versa-Coupler Installation 1. There is an alignment mark on each versa-coupler and four (4) alignment marks on the NeverLube backwash valve port faces. See Figure 4. 2. Slide a versa-coupler into the TO FILTER INLET and the FROM FILTER OUTLET ports on the NeverLube backwash valve. NOTE: Certain filters require two (2) p/n 8044 versa- couplers. 3. Hold the NeverLube backwash valve up to the filter and twist the versa-couplers until they slide into the filter inlet and outlet ports. Tighten the filter union nuts. NOTE: Make sure to align each versa-coupler to the filter and NeverLube backwash valve prior to gluing the assembly. 4. If the alignment marks don't line up, make a mark on the coupler and valve for reassembly. 5. Remove the valve from the filter. Clean the couplers and glue them onto the valve using the alignment marks as a reference. 6. Clean the versa-coupler(s) and glue it onto the filter, matching the valve port marked TO FILTER INLET with the filter inlet. Hold the coupler in place for a minimum of one (1) minute. 7. Plumb the FROM PUMP, POOL RETURN, and WASTE ports as needed. Let the system dry for 24 hours. 8. When the glue is dry, start the system and check for proper water flow. 9. After the glue has dried, flush the system by setting the valve to BACKWASH. Start filter pump(s). Run the system until the waste water is clean. Turn off the filter pump(s) and set the valve to FILTER. Section 5. Backwashing Never attempt to assemble, disassemble or adjust the filter when there is pressurized air in the system. Starting the pump while there is any pressurized air in the system can cause the filter lid to be blown off, which can cause death, serious personal injury or property damage. 1. Turn off all system pump(s). 2. Open the pressure relief valve on top of the filter. Wait for all the air to evacuate the system. 3. Loosen the handle locking knob and turn the valve handle to the BACKWASH position. Tighten the locking knob. 4. Turn on the system pump(s) and run the system until the waste water runs clean. IMPORTANT NOTE: Be sure to follow any and all applicable local codes related to proper discharge/drainage of water from your pool/spa. 5. Close pressure relief valve when water comes out at valve. 6. Turn off all system pump(s). 7. Return the valve handle to the FILTER position. Tighten the locking knob. 8. Turn on system pump(s) and check for normal water flow. Section 4. Normal Operation 1. Make sure the valve handle is pointing towards FILTER. 2. Turn on the filter pump(s). Check the system for normal water flow.

Page 8 ENGLISH Jandy Pro Series, NeverLube Backwash Valve Installation & Operation Manual Section 6. Vacuuming to Waste (Optional) NOTE: To ensure that water will not return to the pool or spa during the "vacuum to waste" operation, a valve is required on the return line to the pool. See Figure 5. Close this valve or for Jandy Pro Series valves, loosen the locking knob and ensure the valve stop is facing the filter return line. 1. Ensure that the pump is OFF (not running and not likely to turn on in "timed filter" or "heat demand" mode). 2. Close valve on return line or Jandy Pro Series valve. See Note above. 3. Loosen locking knob on the NeverLube backwash valve handle. 4. While turning clockwise, lift the valve handle to clear the handle stop on the valve cover. Then align the handle to the WASTE position on the valve cover. This closes the inlet and outlet ports of the filter. 5. Connect vacuuming hose to pool skimmer or the sweep inlet line. Turn on pump and vacuum as desired. 6. After vacuuming to waste, turn off pump, remove vacuuming hose, and return both valves to their normal operating position. Check that controls are once again set for normal operations. Filter Pump Figure 5. Spa Pump Inlet (Bottom Port) Pool Three-way Valve (valve stop towards filter during vacuum operation) Pool Return (Top Port) To Waste Vacuuming to Waste Filter NeverLube Backwash Valve

Jandy Pro Series, NeverLube Backwash Valve Installation & Operation Manual ENGLISH Page 9 Design Head Loss (feet head) 6 5 4 3 2 1 0 0 20 40 60 80 100 120 Flow Rate (gpm) 2.5 2.0 1.5 1.0 0.5 0.0 140 Design Pressure Drop (psi) Figure 6. NeverLube Backwash Valve Head Loss Curve

Page 10 ENGLISH Jandy Pro Series, NeverLube Backwash Valve Installation & Operation Manual Section 7. Replacement Parts List Key No. Description Qty. Model Order Part No. 1 Handle Replacement Kit All R0552100 Locking Knob 1 Handle 1 2 Lid Replacement Kit All R0552200 Lid, Top (Keyed) 1 Lid, Bottom (Keyed) 1 O-ring, 151 2 O-ring, 116 4 Screws, Machine #14 16 Instructions, Replacement Kit 1 3 Diverter Replacement Kit All R0552300 Diverter Shaft 1 Diverter Assembly, Top (Blue Seal) 1 Diverter Assembly, Bottom (Black Seal) 1 Instructions, Replacement Kit 1 4 O-Ring Replacement Kit All R0552400 Par Ring 2 Lid O-ring 2 Diverter O-ring 8 Instructions, Replacement Kit 1 5 Pre-Plumbed Kit w/ Unions 8034J R0414000 PVC Pipe, 2.54" 1 PVC Pipe, 3.04" 1 Coupling O-ring 2 Union Tail Piece/Flange 2 Coupling Nut 2 Instructions, Replacement Kit 2 6 Pre-Plumbed Kit w/ Universal Unions BWV-NVL R0413900 PVC Pipe, 2.54" 1 PVC Pipe, 3.04" 1 Universal Coupling O-ring 2 Universal Union Tail Piece/Flange 2 Universal Coupling Nut 2 Instructions, Replacement Kit 2 7 2" Versa-Coupling 1 All 8044

Jandy Pro Series, NeverLube Backwash Valve Installation & Operation Manual ENGLISH Page 11 Versa- Coupler (2" PVC pipe size p/n 8044, qty. 1) 1/ 2 8 5 / 8 Top View 2 4 3 / 8 6 3 / 4 1 14 3/ 4 4 2 8 3 Front View Right Side View 4 2.54 5,6 3.04 4 3 5,6 4 2

Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 www.zodiacpoolsystems.com ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. All trademarks referenced herein are the property of their respective owners. 2012 Zodiac Pool Systems, Inc. H0551800 Rev G 1206