Touchscreen Thermometer & Timer model 00398

Similar documents
Digital Clock model 75100CAUDI

Humidity Monitor model 00619

Digital Clock model 75100C

Window Thermometer models / / 00423

Thermometer models / 00831A

Thermometer model 00826

Wireless Thermometer model 00380

Wireless Thermometer model 00782W

Thermometer models 02023/02028/02053/02054

Thermometer models 02023, 02028, 02029

Humidity Monitor model 01083

Weather Thermometer models 00754/00771W/00772W/00773W/00774W

Weather Forecaster model / 02045

Thermometer models 00592W / 00592A

Professional Weather Center

Weather Forecaster model 75107TBLA1

Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove.

Weather Forecaster model 00837W

Weather Station model 00510SBDI

Weather Forecast Station model 00828BPDI

Weather Forecaster model 00827

Weather Station model 02048HD

Weather Center model / 01645

5-Piece Grill Tool Set WITH DIGITAL THERMOMETER

Weather Center model 01604

SAVE THIS MANUAL FOR FUTURE REFERENCE.

(Special designed for Duro Gas Grill BI)

Your grill isn t afraid of the dark any more. BBQ Grill Light

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

HR-20P Pneumatically Controlled Pressure Regulator

Owner's Manual. For latest instructions please go to

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Digital Body Weight Scale Model No. EB4074C. Questions or Concerns? (855)

EAGL 1-Touch Laser Level

Harvil 4 Foot Air Hockey Table

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

IAQ-CALC TM Indoor Air Quality Meter

Harvil 4 Foot Air Hockey Table

Owner's Manual. For latest instructions please go to

Harley Davidson FL Touring Current Xtreme

Digital Body Weight Scale

Series 2100 Operating Instructions

VELOCICALC Air Velocity Meter

Cordless Make Up Mirror WITH ILLUMINATED 1X AND 10X MAGNIFICATION PLUS NIGHT LIGHT

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

Loctite Control Timer Part Number EQUIPMENT Operation Manual. Control Timer SEC. Technologies

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Users Guide for Ac-sync

TWO YEAR LIMITED WARRANTY MOMENT NOW PLEASE TAKE A INSTRUCTION MANUAL AND WARRANTY INFORMATION MP-15-THP

Owner's Manual. For latest instructions please go to

EQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

IAQ-CALC TM Indoor Air Quality Meter

MM10 Dual Cartridge Dispenser 1:1 & 2:1 A Style Cartridges MM10 Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridges

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Infrared Thermocouple Probe

ml Dual Cartridge Dispenser 10:1 B Style Cartridge ml Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridge

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Customer Support

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Intelligent Electronic Safe

Tachometer. English. Users Manual

37SCENE 46SCENE 79SCENE

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

SAVE FOR CONSUMER INSTALLATION / OWNER S MANUAL. Includes: Tools: Mystic - Pull-Out Kitchen Faucet LKMY1041CR LKMY1041NK LKLFMY1041CR LKLFMY1041NK D 1

PVI 60KW, PVI 82KW, PVI 95KW

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance

Instant Wine Aerator USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE

Straight-Bore Clutch LSCC-32, 44, 54

AC/DC Digital Air Compressor

Owner's Manual. mycharge name and logo are registered trademarks of RFA Brands RFA Brands. All Rights Reserved. Patent Pending.

Harvil 5 Foot Air Hockey Table

STAINLESS STEEL LCD DIGITAL SCALE

8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.

Installation and Operation Instructions Safety Director Arrow

Cast Iron WARNING CAUTION. CAUTION Some parts may contain sharp edges especially as noted in manual. Wear protective gloves if necessary.

Indoor Air Quality Meter

Zap 5LX-S. Model No.: BH9938U-5-2. Questions or Concerns? (855)

BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

Digital Body Weight Scale Model No.: EB4074C. Questions or Concerns? (855)

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

GLYCOL SYSTEM MONITOR (GSM)

V2700Z OWNER S GUIDE.

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

FCB-450, LCB-600, MCB-800

Frekote Adjustable Spray Applicator 6 Extension Extension Extension EQUIPMENT Operation Manual

DP-CALC TM Micromanometer

USER GUIDE EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY INTELLIBOOST ULTRA RG600 12V 600A REV 1.16B

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Owner s Manual & Safety Instructions

MaxLite LED Linear HighBay Fixtures

User s Manual Chase on the Case Cruiser

2060F / 2062F / 2064F

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

RipTide. Brewing Pump. Assembly, Operation, & Maintenance

Transcription:

Instruction Manual Touchscreen Thermometer & Timer model 00398 CONTENTS Unpacking Instructions... 2 Package Contents... 2 eatures & Benefits... 3 Thermometer Setup... 4 Select Temperature Units... 4 ood Preparation... 5 Using the Thermometer... 5 Troubleshooting... 7 Care & Maintenance... 7 Specifications... 7 Customer Support... 7 Warranty... 8 Questions? Contact Customer Support at (877) 221-1252 or visit www.acurite.com. SAVE THIS MANUAL OR UTURE REERENCE.

Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference. Unpacking Instructions Remove the protective film that are applied to the LCD screen prior to using this product. Locate the tab and peel off to remove. Package Contents 1. Touchscreen Thermometer 2. Temperature Probe & Cord 3. Instruction Manual IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE PRODUCT REGISTRATION Register online to receive 1 year warranty protection www.acurite.com NOTE: These products are not intended for use in cooking environments that exceed 482º (250ºC), as the probe may melt or catch fire, creating a hazard to the user. 2

eatures & Benefits 9 1 BEE 8 7 10 START 2 6 3 4 5 11 RONT O DISPLAY 1. Meat Doneness Selection Select Medium Rare, Medium or Well Done; temperatures based on USDA recommended guidelines. 2. & Buttons or setup preferences. 3. Indicator Indicates an audible alert will sound when target temperature is reached. 4. Target Temperature 5. Button or setup preferences. 6. Button Press to enter timer mode. 7. Current Temperature Arrow icon indicates the direction the temperature is trending. 8. Button Press to enter thermometer mode. 9. Meat Type Selection Select Beef, Veal, Burger, Pork, Poultry, Lamb, ish, or Custom. 10. Probe Plug-in 11. Timer 3

SETUP Install or Replace Batteries AcuRite recommends high quality alkaline batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended. 1. Slide off the battery compartment cover. 2. Insert 2 x AAA batteries into the battery compartment, as shown. ollow the polarity (+/-) diagram in the battery compartment. 3. Replace the battery cover. Select Temperature Units To select between degrees ahrenheit (º) or Celsius (ºC) temperature units, press and release the ºC/º button, located in the battery compartment of the thermometer. PLEASE DISPOSE O OLD OR DEECTIVE BATTERIES IN AN ENVIRONMENTALLY SAE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS. BATTERY SAETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment that will not be used for an extended period of time. ollow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals. 4

OPERATION ood Preparation Consuming raw or undercooked meats, poultry, seafood, shellfish, or eggs may increase your risk of food-borne illness, especially if you have certain medical conditions. The USDA recommends certain guidelines be met when preparing meat and seafood. Please adhere to the recommended cooking temperatures. Beef, Pork, Veal & Lamb Steaks, chops, roasts Ground meats USDA Recommended Guidelines Minimum Internal Temperature Product & Rest Time 145 (62.8 C) and allow to rest for at least 3 minutes 160 (71.1 C) All Poultry 165 (73.9 C) ish & Shellfish 145 (62.8 C) or more information on food preparation safety, visit: http://www.fsis.usda.gov Using the Thermometer 1. Before operating, plug the temperature probe into the thermometer display. 2. Press the button to enter thermometer mode. Meat Type & Doneness Setup 1. When first powered on, COOK will be shown on the display. 2. To adjust meat type and doneness preferences, press and release the COOK icon to cycle through meat type presets. The meat type set order is as follows: CUSTOM, BEE, VEAL, BURGER, LAMB, PORK, POULTRY, ISH. The doneness set order is as follows: MEDIUM RARE, MEDIUM, WELL. The target temperature will automatically adjust based on your selections. NOTE: Not all meat types offer all three doneness options. In some cases, a doneness option is not available at all. 3. To manually adjust the target temperature, press and release the target temperature value shown on the display. The target temperature will begin to flash. Press and release the or buttons to adjust the target temperature. CUSTOM will now be shown as your selected meat type. 4. Press and release the button to confirm your selections. 5

Current Temperature 1. Insert the narrow end of the temperature probe into the thickest part of the food being cooked. Be sure the tip is not touching bone, gristle, the pan or inserted into the cavity of fowl. 2. Hold steady for several seconds. 3. Current internal temperature of the meat will show on the display. 4. The arrow icon next to the current temperature reading indicates the direction temperature is trending. 5. When the current temperature of the food reaches the target temperature, the thermometer will beep. Be careful when touching the temperature probe and probe wire if it has been in or near hot food or surfaces. Timer Setup 1. Press the button to enter Timer mode. TIMER will be shown on the display. 2. Press and release the value (minutes or seconds) that you wish to adjust. The selected value will begin to flash. 3. Press and release the and buttons to adjust the desired time limit. 4. Press and release the button to confirm your selection. 5. Press and release START to begin the countdown. Press and release STOP to pause the countdown. After pausing, press and release the button to clear the time displayed. 6. To use the count up function, press and release START while the display reads 00:00. Automatic Shutoff The unit will automatically power off after one or more of the following conditions are met: 4+ hours of no temperature change 4+ hours of button inactivity Probe is unplugged for 2+ minutes To manually power off the unit, press and hold either the or button for 3 seconds. 6

Troubleshooting Problem CHECK PROBE is displayed Display screen not working If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.acurite.com or call (877) 221-1252 for assistance. Care & Maintenance Store in a dry location at room temperature. Clean thermometer with a soft, damp cloth. Temperature probe should be wiped clean with warm water immediately after direct contact with foods. DO NOT place display on or near hot surfaces. DO NOT heat beyond thermometer s temperature capacity. DO NOT use in oven. DO NOT wash in dishwasher. DO NOT immerse in water or use caustic cleaners or abrasives. DO NOT allow any part of the temperature probe or probe wire to come into direct contact with flames or flare-ups. DO NOT bend or crimp the temperature probe cord. DO NOT lift or move the thermometer by the temperature probe wire connection. Specifications TEMPERATURE RANGE TIMER RANGE POWER Solution CHECK PROBE indicates a probe error. Probe cord is not functioning properly. Cord may have been damaged or exposed to extreme heat. Check the wire and connection for damage or excessive heat. Replace cord. Probe cord is not connected to the thermometer. Verify cord connection is secure or reconnect cord. Check that the batteries are installed correctly. Batteries may need to be replaced. -40º to 482º (-40ºC to 250ºC) Probe cord heat resistant up to 700º (371ºC) 99 minutes, 59 seconds 2 x AAA alkaline batteries Customer Support AcuRite customer support is committed to providing you with best-in-class service. or assistance, please have the model number of this product available and contact us in any of the following ways: (877) 221-1252 Visit us at www.acurite.com Installation Videos Replacement Parts Register your Product Instruction Manuals Support User orum Submit eedback & Ideas 7

Limited 1-Year Warranty AcuRite is a wholly owned subsidiary of Chaney Instrument Company. or purchases of AcuRite products, AcuRite provides the benefits and services set forth herein. or purchases of Chaney products, Chaney provides the benefits and services set forth herein. We warrant that all products we manufacture under this warranty are of good material and workmanship and, when properly installed and operated, will be free of defects for a period of one year from the date of purchase. Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by us, and at our sole option, be repaired or replaced by us. Transportation costs and charges for returned goods shall be paid for by the purchaser. We hereby disclaim all responsibility for such transportation costs and charges. This warranty will not be breached, and we will give no credit for products which have received normal wear and tear not affecting the functionality of the product, been damaged (including by acts of nature), tampered, abused, improperly installed, or repaired or altered by others than our authorized representatives. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). If we determine that repair or replacement is not feasible, we may, at our option, refund the amount of the original purchase price. THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY OR THE PRODUCTS AND IS EXPRESSLY IN LIEU O ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET ORTH HEREIN ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY O MERCHANTABILITY AND THE IMPLIED WARRANTY O ITNESS OR A PARTICULAR PURPOSE. We expressly disclaim all liability for special, consequential, or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. We further disclaim liability from personal injury relating to our products to the extent permitted by law. By acceptance of any of our products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm or corporation is authorized to bind us to any other obligation or liability in connection with the sale of our products. urthermore, no person, firm or corporation is authorized to modify or waive the terms of this warranty unless done in writing and signed by a duly authorized agent of ours. In no case shall our liability for any claim relating to our products, your purchase or your use thereof, exceed the original purchase price paid for the product. Applicability of Policy This Return, Refund, and Warranty Policy applies only to purchases made in the United States and Canada. or purchases made in a country other than the United States or Canada, please consult the policies applicable to the country in which you made your purchase. Additionally, this Policy applies only to the original purchaser of our products. We cannot and do not offer any return, refund, or warranty services if you buy products used or from resale sites such as ebay or Craigslist. Governing Law This Return, Refund, and Warranty Policy is governed by the laws of the United States and the State of Wisconsin. Any dispute relating to this Policy shall be brought exclusively in the federal or State courts having jurisdiction in Walworth County, Wisconsin; and purchaser consents to jurisdiction within the State of Wisconsin. Weather Stations Temperature & Humidity Weather Alert Radio It s More than Accurate, it s Kitchen Thermometers & Timers Clocks AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to Plan your day with confidence. www.acurite.com Printed in China 00398 INST 071417 Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.acurite.com/patents for details.