Air Circuit Breakers

Similar documents
Air Circuit Breakers

SENTRON 3WL5 Air Circuit Breakers/ Non-Automatic Air Circuit Breakers according to UL 489/IEC

SIEMENS 3WL Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers

Siemens AG WT Air Circuit Breakers up to 4000 A. Catalog LV SENTRON. Answers for infrastructure.

SENTRON Switching and Protection Devices Molded Case Circuit Breakers

3VT Kompaktleistungsschalter bis 630A

Low-Voltage Controls and Distribution

3VF3 to 3VF8 Circuit-Breakers

3NP1 Fuse Switch Disconnectors up to 630 A

WL Low Voltage Metal-Enclosed Switchgear. Selection and Application Guide.

Protection Equipment

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Catalog LV 1 Add-On October sentron CIRCUIT-BREAKERS. 3VL Molded Case Circuit-Breakers approved according to UL 489 up to 1600 A

DMX 3 -I 2500 switch disconnectors

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

WL Low Voltage Metal-Enclosed Switchgear

Siemens AG 2017 SENTRON. 3VA Molded Case Circuit Breakers with UL and IEC Certification. Edition 10/2017. siemens.com/3va

SIRIUS 3RU2 Thermal Overload Relays

BETA Low-Voltage Circuit Protection

MOULDED CASE CIRCUIT BREAKERS BC160N

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

3VT5 Molded Case Circuit Breakers up to 1600 A

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

3VU13, 3VU16 Circuit-Breakers

Protection Equipment. 5/2 Introduction

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Critical Power Switchboards. Selection and Application Guide

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

3VT5 Molded Case Circuit Breakers up to 1600 A

Control Circuit Protection

DPX moulded case circuit breakers

3VA Circuit Breaker Compact. Global. Next- Gen! Brandon Castro and Fred Myers Manufacturing in America 02/22-23/2017

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

BETA Switching Switches and Light Indicators

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

3VT2 Molded Case Circuit Breakers up to 250 A

Siemens AG Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12 SIRIUS. Catalog Add-On IC 10 AO. Edition Answers for industry.

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

Protective Devices: Circuit-Breakers 1 )

Selection and Application Guide usa.siemens.com/circuitbreakers

Advanced retrofitting kits solutions for Megamax Megamax Emax 2

ENYSTAR Load Centers up to 250 A

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

Sitras SCS, -RCI, -FFP, -TTU

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

SENTRON Switching and Protection Devices Switch Disconnectors

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

For Operation in the Control Cabinet 3RW Soft Starters

ABB s new control and protection devices

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

System Manual 02/2008

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Contents. We build a better future! MCC HCB

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

Motor Applications Automation. Command and Signalling Power Management Product Overview for Machinery

3RW Soft Starters. General data. 6/4 Siemens LV

3VT1 Molded Case Circuit Breakers up to 160 A

CPG.0 Single busbar gas-insulated cubicles

Overcurrent releases - description, specifications, characteristics specifications specifications description...

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

SENTRON VL Series Product Specifications

General data 5/37. Overview

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Manual. Industrial Controls. Protection Devices. SIRIUS 3RV Motor Starter Protectors. Edition 12/2017. siemens.com

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Selection Guide Motor Control Device Solutions

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

BETA Fuses and Fuse Systems

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

DATA SHEET 3VT3 MCCB ACCESSORIES

Motor Circuit Breakers C3

Power Supplies. 11/2 Introduction

Motor Circuit Breakers C4

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

3 - Protection components Motor circuit-breakers

cor Long Run Experience

Magnum IEC Low Voltage Air Circuit Breakers

Air-insulated switchgear UniGear type ZS1

Customized for maximum demands. SIVACON Technology Partner. SIVACON S8 low-voltage power distribution board: safe, flexible, efficient

Power Break II Switchboard

Original Manual 2CCC444010M0201 Rev. 1.0, Date of Release: 02/2016. Remote Power Panel Assembly instructions

Molded-Plastic Distribution Systems

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

SIRIUS SENTRON SIVACON

DEVICE STATE/BYPASSED FAILURE OVERLOAD

UBW Family UL489 Molded Case Circuit Breakers

Short form catalogue. Motor protection & control

Transcription:

Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23 4-pole, fixed-mounted versions /30 4-pole, withdrawable versions /37 /44 Accessories and spare parts 3WL non-automatic air circuit breakers up to 4000 A (DC) /66 3- and 4-pole, fixed-mounted versions /67 3- and 4-pole, withdrawable versions /69 Accessories and spare parts Ch. 2 3KC ATC5300 transfer control devices For further technical product information: Service&Support portal: www.siemens.com/lowvoltage/ technical-support. Product list: Technical specifications Entry list: Updates / Downloads / FAQs / Manuals / Operating instructions / Characteristic curves / Certificates Siemens LV 0. 203

* +, - Siemens AG 203 Introduction Overview Devices Page Applications/ Individual components Standards Used in Non-residential buildings Residential buildings Industry 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /9... /36 As incoming-feeder, distribution, tie, and outgoing-feeder circuit breakers in electrical installations. For switching and protecting motors, capacitors, generators, transformers, busbars and cables. IEC 60947-2, climate-proof according to IEC 60068-2-30 -- 3WL non-automatic air circuit breakers up to 4000 A (DC) /66... /68 As incoming-feeder, distribution, tie, and outgoing-feeder circuit breakers in electrical installations. For switching and protecting motors, capacitors, generators, transformers, busbars and cables. IEC 60947-2, climate-proof according to IEC 60068-2-30 --! ) 5 - ' ' > Protective devices with device holder and optional measurement function (ETU) /5 Electronic Trip Unit with protection functions LI, LSI, LSING and LSIN(G), with or without measurement function Plus Rating Plugs /5 For rated currents I n from 250 A to 6300 A. The maximum rated current of the circuit breaker must not be exceeded. As for circuit breakers -- As for circuit breakers -- 5 /. ) 6 " # Ground-fault modules /5 With alarm and tripping As for circuit breakers --.. C 6 4 2 / ) ) ) 4 ) ) 4 J C I # " 6 4 2! JC 5 -! " # Displays /5 4-line displays for ETU45B As for circuit breakers -- 5 - $ ' Current transformers for N conductor protection /5 Internal transformers for N conductors, external transformers for N conductors As for circuit breakers -- 5 - ' '. % EMC filters /5 Common-mode interference suppressor filters More accessories for Electronic Trip Units /52 Sealable and lockable covers, automatic reset of the reclosing lockout, remote reset solenoid, retrofittable internal CubicleBUS wiring, retrofittable internal wiring for connection of external N and G transformers As for circuit breakers -- As for circuit breakers -- 5 - ' ' ' = NSE0_00987 NSE0_00982 Locking devices /52 Interlocking set for mechanical ON/OFF, As for circuit breakers -- locking devices against unauthorized closing in operator panels/for withdrawable circuit breakers, locking devices for operating mechanism handle with padlock, locking devices to prevent movement of the withdrawable circuit breakers, interlocking systems Locking mechanisms /53 To prevent movement of the withdrawable As for circuit breakers -- circuit breakers into disconnected position, to prevent opening of the cabinet door in ON position, to prevent opening of the cabinet door, to prevent movement with the cabinet door open Interlocks /54 Mutual mechanical interlocking, couplings on the circuit breaker (with ring) for mutual interlocking, Bowden wire As for circuit breakers -- NSE0_00989 /2 Siemens LV 0. 203

Siemens AG 203 Introduction Devices Page Applications/ Individual components Standards Used in Non-residential buildings Residential buildings Industry Test devices /54 Manual tester Release 2 for Electronic As for circuit breakers -- Trip Units, function testers Capacitor storage devices /54 For shunt releases As for circuit breakers -- 5 - ' ' # = 5 - $ ' Indicators, control elements /55 Ready-to-close signaling switches, As for circuit breakers -- signaling switches, tripped signaling switches, operating cycles counters, stored energy status signaling switches, position signaling switches for guide frames, electric ON buttons, motor shutdown switches, EMERGENCY-STOP buttons Auxiliary conductor connections /56 Male connectors for circuit breakers, extension for 000 V male connector versions, male connectors and extension for 000 V, auxiliary supply connectors for circuit breakers or guide frames, coding kits, sliding contacts for guide frames, blanking blocks for circuit breakers As for circuit breakers -- Auxiliary releases /57 Closing solenoids/shunt releases, As for circuit breakers -- undervoltage releases Operating mechanisms /57 Motorized operating mechanism As for circuit breakers -- Auxiliary contacts /57 Auxiliary switch blocks As for circuit breakers -- Door sealing frames, hoods, shutters /58 Door sealing frames, IP55 protective covers, shutters As for circuit breakers -- Arc chutes /58 Arc chutes, arc chute covers As for circuit breakers -- Coding for withdrawable version /58 By customer, for 36 coding variants As for circuit breakers -- Grounding connections /59 Grounding connection between the guide frame and the withdrawable circuit breaker, contacting modules for withdrawable circuit breakers Support brackets /59 For mounting fixed-mounted circuit breakers on vertical plane CubicleBUS modules /59 Digital and analog input and output modules, Zone Selective Interlocking modules Parameterization systems /59 Breaker Data Adapter (BDA), BDA Plus, Connection cables for BDA Plus, powerconfig parameterization software Accessories for communications /60 Factory-fitted cables for CubicleBUS modules, SENTRON manuals for communication solutions, voltage transformers Retrofitting and spare parts /60 PROFIBUS retrofit kits, COM5 PROFIBUS modules, COM6 MODBUS modules, MODBUS IEC retrofit kits, Breaker Status Sensor (BSS), measurement function Plus As for circuit breakers -- As for circuit breakers -- As for circuit breakers -- As for circuit breakers -- As for circuit breakers -- As for circuit breakers -- Main conductor connections, fixed-mounted Main conductor connections, withdrawable /6 /62 Front-accessible main connections with double or single hole, rear vertical main connections, rear horizontal main connections, circuit connecting flanges, supports for front and DIN connecting bars As for circuit breakers -- Siemens LV 0. 203 /3

Rating Plug Siemens AG 203 Introduction I Air circuit breakers 3WL air circuit breakers/non-automatic air circuit breakers up to 6300 A (AC), IEC I, II, III II Rated current I n A 630, 800, 000, 250, 600, 2000, 2500, 3200, 4000, 5000, 6300 Number of poles 3-pole, 4-pole 3-pole, 4-pole Rated operational voltage U e Rated ultimate short-circuit breaking capacity at 500 V AC Endurance Mounting position II V AC V DC ka Operating cycles... 690/000/50 -- I 55/66/85 3WL non-automatic air circuit breakers up to 4000 A (DC) Transfer control devices 3KC ATC5300 transfer control devices 000, 2000, 4000 see chapter "Monitoring devices". --... 000 II 66/80/00 III 00/50 (3-pole), 30 (4-pole) Up to 20000 5000 0000 5000 30 30 III 30 30 30/25/20 (at 300/600/000 V DC) 30 30 30 30 ATC5300 H NSS0_00535 Degree of protection With cover IP55 IP55 Without cover IP4 IP4 (with door sealing frame) Dimensions W mm 320/40 460/590 704/94 460/590 3-/4-pole Fixedmounted D mm 29 29 29 H mm 434 434 434 434 B T 29 Withdrawable NSE0_0006a NSE0_00062a H mm 465.5 465.5 465.5 465.5 D mm 47 47 47 47 NSE0_0006a NSE0_00062a Electronic Trip Units for 3WL air circuit breakers Type ETU5B ) ETU25B ETU27B ETU45B ETU76B Overload protection Short-time delayed -- short-circuit protection Instantaneous short-circuit protection Neutral conductor protection -- -- Ground-fault protection -- -- Zone Selective Interlocking -- -- -- LCD, 4-line -- -- -- -- LCD, graphic -- -- -- -- Communication -- -- -- Measurement function Plus -- -- -- Selectable parameter sets -- -- -- -- Parameters freely programmable -- -- -- -- CubicleBUS -- -- -- Standard -- Not available Optional ) ETU5B cannot be used with 3WL air circuit breakers, size III. NSE0_006a NSE0_007a NSE0_008a NSE0_009a 3WL air circuit breakers/non-automatic air circuit breakers according to UL 489 up to 5,000 A, see Catalog LV 6. 3KC ATC5300 transfer control devices, see chapter "Monitoring Devices". NSE0_0a /4 Siemens LV 0. 203

Siemens AG 203 Introduction Breaking capacity I II III Type 3WL 3WL2 3WL3 Breaking capacity class N S H N S H H C C N S H N S H H C 3-pole 4-pole C Short-circuit breaking capacity Rated operational voltage U e up to 45 V AC I cu ka 55 66 85 66 80 00 00 50 30 I cs ka 55 66 85 66 80 00 00 50 30 I cm ka 2 45 87 45 76 220 220 330 286 Rated operational voltage U e up to 500 V AC I cu ka 55 66 85 66 80 00 00 50 30 I cs ka 55 66 85 66 80 00 00 50 30 I cm ka 2 45 87 45 76 220 220 330 286 Rated operational voltage U e up to 690 V AC I cu ka 42 50 66 50 75 85 85 50 30 I cs ka 42 50 66 50 75 85 85 50 30 I cm ka 88 05 45 05 65 87 87 330 286 Rated operational voltage U e up to 000 V/50 V AC I cu ka -- -- 50 9) -- -- 50 50 70 4) 70 4) I cs ka -- -- 50 9) -- -- 50 50 70 4) 70 4) I cm ka -- -- 05 9) -- -- 05 05 54 4) 54 4) Rated short-time withstand current I cw of the circuit breakers 3) 0.5 s ka 55 66 75 66 80 00 00 00 00 s ka 42 50 66 55 66 80 00 00 00 2 s ka 29.5 35 46 39 46 65 ) /70 2) 80 80 80 3 s ka 24 29 37 32 44 50 ) /65 2) 65 65 65 Short-circuit breaking capacity I cc of the non-automatic air circuit breakers Up to 500 V AC ka 55 66 75 66 80 00 00 00 00 Up to 690 V AC ka 42 50 66 50 75 85 85 00 00 Up to 000 V /50 V AC ka -- -- 50 9) -- -- 50 4) 50 4) 70 4) 70 4) Type Breaking capacity class Short-circuit breaking capacity Up to 220 V DC I cc Up to 300 V DC I cc Up to 600 V DC I cc Up to 000 V DC I cc Rated short-time withstand current I cw 0.5 s s 2 s 3 s ka ka ka ka II 3WL2 DC 35 30 25 20 DC ka -- ka 35 5) /30 6) /25 7) /20 8) ka -- ka -- N S H C DC Note: Circuit breaker with ECO breaking capacity N Circuit breaker with standard breaking capacity S Circuit breaker with high breaking capacity H Circuit breakers with very high breaking capacity C Non-automatic air circuit breakers with DC breaking capacity These breaking capacities are indicated in the corresponding tables by the symbols shown on orange backgrounds. For further technical specifications see the configuration manual "". Free download from: www.siemens.com/lowvoltage/manuals ) II with I n max 2500 A. 2) II with I n max = 3200 A and I n max = 4000 A. 3) At a rated voltage of 690 V the I cw value of the circuit breaker cannot be greater than the I cu or I cs value at 690 V. Abbreviations* English long text Explanation (functions) L Long Time Delay Overload protection S Short Time Delay Short-circuit protection (short-time delayed) I Instantaneous Short-circuit protection (instantaneous) N Neutral Protection Neutral conductor protection G Ground Fault Ground-fault protection * Designations according to IEC 60947-2, Appendix K. 4) Rated operational voltage U e = 50 V. 5) At U e = 220 V DC. 6) At U e = 300 V DC. 7) At U e = 600 V DC. 8) At U e = 000 V DC. 9) Values also apply to 690 V + 20 % version with Z-option "A6". Siemens LV 0. 203 /5

Siemens AG 203 Introduction 3WL air circuit breakers: Superior individual products integrated into uniform power distribution systems - up to and including industry-specific industrial and infrastructure solutions 6 2 7 3 8 4 5 25 9 2 9 0 22 23 2 24 8 3 7 20 6 5 4 NSE0_0887d $ Guide frame (pages /45 to /50) % Main circuit connection front, flange, horizontal, vertical (pages /42, /6 and /62) & Position signaling switch (pages /40 and /55) ( Grounding connection, leading (page /59) ) Shutters (pages /40 and /58) * COM5 PROFIBUS module or COM6 MODBUS module (pages /40 and /60) + External CubicleBUS modules (page /59), Closing coil, auxiliary release (pages /37, /39 and /57) - Auxiliary conductor plug-in system (pages /4 and /56). Auxiliary switch block (pages /37 and /57) / Door sealing frame (pages /39 and /58) 0 Interlocking set for mechanical ON/OFF (page /52) Transparent panel, function insert (page /52) 2 EMERGENCY-STOP pushbutton, key operated (page /55) 3 Motorized operating mechanism (pages /39 and /57) 4 Operating cycles counters (pages /39 and /55) 5 Breaker status sensor (BSS) (pages /40 and /60) 6 Protective device with device holder, Electronic Trip Unit (ETU) (page /5) 7 Remote reset solenoid (pages /39 and /52) 8 Breaker data adapter (BDA Plus) (page /59) 9 Four-line display (page /5) : Ground-fault protection module (page /5) ; Rating plug (pages /38 and /5) < Measurement function module (pages /40 and /5) = Air circuit breaker (pages /9 to /36) /6 Siemens LV 0. 203

Siemens AG 203 Introduction Communication-capable circuit breakers (with ETU45B or ETU76B Electronic Trip Unit) 8 Ethernet 6 7 PROFIBUS 4 4 9 2 3 4 5 5 from Release 2 7 CubicleBUS 8 9 6 2 3 0 NSE0_005l 2 3 4 5 6 7 8 9 0 3VL molded case circuit breakers Electronic Trip Unit LCD Electronic Trip Unit COM20 Release 2 PROFIBUS module ) Including ZSS BDA Plus with Ethernet interface 3WL air circuit breakers COM5 PROFIBUS module 2) Breaker status sensor (BSS) Electronic Trip Unit Measurement function Plus 2 3 4 5 6 7 8 9 Zone Selective Interlocking modules Digital output module with relay contacts Digital output module with relay contacts, configurable Analog output modules Digital input module powerconfig as of V2.3 PLC, e. g. SIMATIC S7 e. g. Powermanager or SIMATIC powerrate 7KM PAC measuring devices ) For a MODBUS-RTU connection the COM2 module is required. 2) For a MODBUS-RTU connection the COM6 module is required. Features Coordinated communication concept using the PROFIBUS DP or MODBUS, ranging from 6 A to 6300 A with 3VL molded case circuit breakers and 3WL air circuit breakers The high level of modularity of circuit breakers and accessories allows easy retrofitting of all communication components Significant additional benefits for the switchgear due to the possibility of linking up external input and output modules to the circuit breaker-internal CubicleBUS of the 3WL Innovative software products for parameterization, operation, monitoring, and diagnostics of circuit breakers, both locally or via PROFIBUS DP, MODBUS or Ethernet/Intranet/Internet Complete integration of the circuit breakers into the Totally Integrated Power and Totally Integrated Automation solutions Communication: For air circuit breakers with optional communication function (ETU45B or ETU76B Electronic Trip Unit) see pages /9 to /36. For accessories see pages /59 and /60. For more information see also chapters "Measuring Devices and Power Monitoring" and "Software". Siemens LV 0. 203 /7

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC Introduction Benefits Low space requirements The 3WL air circuit breakers require very little space. I devices (up to 2000 A) fit into a 400 mm wide switchgear panel. III devices (up to 6300 A) are the smallest of their kind and with their construction width of 704 mm fit into an 800 mm wide switchgear panel. Modular design Components like auxiliary releases, motorized operating mechanisms, Electronic Trip Units, current transformers, auxiliary circuit signaling switches, automatic reset devices, interlocks and engagement operating mechanisms can all be exchanged or retrofitted at a later stage, thus allowing the circuit breaker to be adapted to new, changing requirements. The main contact elements can all be replaced in order to increase the endurance of the circuit breaker. Retrofittable modules for Electronic Trip Units Modularity is one of the main features of the new 3WL air circuit breakers. Special LCDs, ground-fault modules, rating plugs and communication modules for the Electronic Trip Units are available for fast and easy retrofitting and adaptation to changing requirements. Communication/measurement functions The use of modern communication-capable circuit breakers opens up completely new possibilities in terms of start-up, parameterization, diagnostics, maintenance and operation. This allows many different ways of reducing costs and improving productivity in industrial plants, buildings and infrastructure projects to be achieved: Conductor cross-sections Fast and reliable parameterization Timely information and response can prevent plant stoppages Effective diagnostics management Measured values are the basis for efficient load management, for drawing up power demand profiles and for allocating energy to cost centers Preventive maintenance reduces the risk of expensive plant downtimes Measurement function with a very wide range of measured values, such as current, voltage, energy, power etc. Can be used in 000 V AC and 690 V IT networks Applications As incoming-feeder, distribution, tie, and outgoing-feeder circuit breakers in electrical installations. For switching and protecting motors, capacitors, generators, transformers, busbars and cables. When connected to an electronic I&C system, the air circuit breakers offer a wide range of options for monitoring network events. The extensive, coordinated SENTRON range of devices covers applications between 6 A and 6300 A with molded case and air circuit breakers. The AC devices are available as circuit breakers and non-automatic air circuit breakers. DC devices are only available as nonautomatic air circuit breakers. Standards 3WL air circuit breakers comply with: IEC 60947-2 Climate-proof according to IEC 60068-2-30. Versions with UL 489 also available, see Catalog LV 6. For further standards, see Appendix. I II Type Up to 3WL 2 3WL 6 3WL 20 3WL2 08 3WL2 0 3WL2 2 3WL2 6 3WL2 20 3WL 0 Permissible load for withdrawable versions at rear horizontal main connections Main conductor minimum cross-sections Up to 55 C (Cu bare) Up to 60 C (Cu bare) ) Up to 70 C (Cu black painted) ) Copper bars, bare Copper bars, painted black A 000 A 000 A 000 Unit(s) mm 2 60 0 Unit(s) mm 2 60 0 250 250 20 2 40 0 2 40 0 600 600 490 2) 2 50 0 2 50 0 2000 930 780 3 50 0 3 50 0 800 800 800 50 0 50 0 000 000 000 60 0 60 0 250 250 250 2 40 0 2 40 0 600 600 600 2 50 0 2 50 0 2000 2000 2000 3 50 0 3 50 0 II III Type 3WL2 25 3WL2 32 3WL2 40 3) 3WL3 40 3WL3 50 3WL3 63 3) Permissible load for withdrawable versions at rear horizontal main connections Main conductor minimum cross-sections Up to 55 C (Cu bare) Up to 60 C (Cu bare) ) Up to 70 C (Cu black painted) ) Copper bars, bare Copper bars, painted black A 2500 A 2500 A 2280 Unit(s) 2 mm 2 00 0 Unit(s) 2 mm 2 00 0 3200 3020 2870 3 00 0 3 00 0 ) ETU76B can be used up to max. 55 C. 2) At breaking capacity H: 600 A up to 70 C 3) With rear vertical connections 4) II, 3-pole, in fixed-mounted version 5) Minimum main conductor cross-sections for 4-pole withdrawable circuit breakers: 4 20 mm 0 mm 3950 4) 380 3600 4 20 0 4 00 0 5) 4000 4000 4000 4 x 00 x 0 4 00 0 5000 5000 5000 6 x 00 x 0 6 00 0 5920 580 5500 6 x 20 x 0 6 20 0 /8 Siemens LV 0. 203

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, fixed-mounted versions Selection and ordering data Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N N Basic price A A ka kg Horizontal main circuit connection I 630 630 55 3WL 06-2@@32-@@@@ unit 03 43.000 800 800 3WL 08-2@@32-@@@@ unit 03 43.000 000 000 3WL 0-2@@32-@@@@ unit 03 43.000 250 250 3WL 2-2@@32-@@@@ unit 03 43.000 600 600 3WL 6-2@@32-@@@@ unit 03 43.000 2000 2000 3WL 20-2@@32-@@@@ unit 03 43.000 II 800 800 66 3WL2 08-2@@32-@@@@ unit 03 56.000 000 000 3WL2 0-2@@32-@@@@ unit 03 56.000 250 250 3WL2 2-2@@32-@@@@ unit 03 56.000 600 600 3WL2 6-2@@32-@@@@ unit 03 56.000 2000 2000 3WL2 20-2@@32-@@@@ unit 03 56.000 2500 2500 3WL2 25-2@@32-@@@@ unit 03 59.000 3200 3200 3WL2 32-2@@32-@@@@ unit 03 64.000 Vertical main circuit connection I 630 630 55 3WL 06-2@@3-@@@@ unit 03 43.000 800 800 3WL 08-2@@3-@@@@ unit 03 43.000 000 000 3WL 0-2@@3-@@@@ unit 03 43.000 250 250 3WL 2-2@@3-@@@@ unit 03 43.000 600 600 3WL 6-2@@3-@@@@ unit 03 43.000 2000 2000 3WL 20-2@@3-@@@@ unit 03 43.000 II 800 800 66 3WL2 08-2@@3-@@@@ unit 03 56.000 000 000 3WL2 0-2@@3-@@@@ unit 03 56.000 250 250 3WL2 2-2@@3-@@@@ unit 03 56.000 600 600 3WL2 6-2@@3-@@@@ unit 03 56.000 2000 2000 3WL2 20-2@@3-@@@@ unit 03 56.000 2500 2500 3WL2 25-2@@3-@@@@ unit 03 59.000 3200 3200 3WL2 32-2@@3-@@@@ unit 03 64.000 4000 4000 3WL2 40-2@@3-@@@@ unit 03 85.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 2) Electronic Trip Units Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB ETU76B: Protection functions LSIN 3) NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LSING 3)5) EG ETU45B: Protection functions LSING 3)5) FG ETU76B: Protection functions LSING 3)5) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 3) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. 6) ETU5B cannot be used with 3WL air circuit breakers, size III. Siemens LV 0. 203 /9

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, fixed-mounted versions Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N N Basic price A A ka kg Front main circuit connection, single hole I 630 630 55 3WL 06-2@@33-@@@@ unit 03 43.000 800 800 3WL 08-2@@33-@@@@ unit 03 43.000 000 000 3WL 0-2@@33-@@@@ unit 03 43.000 250 250 3WL 2-2@@33-@@@@ unit 03 43.000 600 600 3WL 6-2@@33-@@@@ unit 03 43.000 II 800 800 66 3WL2 08-2@@33-@@@@ unit 03 56.000 000 000 3WL2 0-2@@33-@@@@ unit 03 56.000 250 250 3WL2 2-2@@33-@@@@ unit 03 56.000 600 600 3WL2 6-2@@33-@@@@ unit 03 56.000 2000 2000 3WL2 20-2@@33-@@@@ unit 03 56.000 2500 2500 3WL2 25-2@@33-@@@@ unit 03 59.000 3200 3200 3WL2 32-2@@33-@@@@ unit 03 64.000 Front main circuit connection, double hole I 630 630 55 3WL 06-2@@34-@@@@ unit 03 43.000 800 800 3WL 08-2@@34-@@@@ unit 03 43.000 000 000 3WL 0-2@@34-@@@@ unit 03 43.000 250 250 3WL 2-2@@34-@@@@ unit 03 43.000 600 600 3WL 6-2@@34-@@@@ unit 03 43.000 2000 2000 3WL 20-2@@34-@@@@ unit 03 43.000 II 800 800 66 3WL2 08-2@@34-@@@@ unit 03 56.000 000 000 3WL2 0-2@@34-@@@@ unit 03 56.000 250 250 3WL2 2-2@@34-@@@@ unit 03 56.000 600 600 3WL2 6-2@@34-@@@@ unit 03 56.000 2000 2000 3WL2 20-2@@34-@@@@ unit 03 56.000 2500 2500 3WL2 25-2@@34-@@@@ unit 03 59.000 3200 3200 3WL2 32-2@@34-@@@@ unit 03 64.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 2) Electronic Trip Units Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB ETU76B: Protection functions LSIN 3) NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LSING 3)5) EG ETU45B: Protection functions LSING 3)5) FG ETU76B: Protection functions LSING 3)5) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 3) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. 6) ETU5B cannot be used with 3WL air circuit breakers, size III. /0 Siemens LV 0. 203

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, fixed-mounted versions Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S S Basic price A A ka kg Horizontal main circuit connection I 630 630 66 3WL 06-3@@32-@@@@ unit 03 43.000 800 800 3WL 08-3@@32-@@@@ unit 03 43.000 000 000 3WL 0-3@@32-@@@@ unit 03 43.000 250 250 3WL 2-3@@32-@@@@ unit 03 43.000 600 600 3WL 6-3@@32-@@@@ unit 03 43.000 2000 2000 3WL 20-3@@32-@@@@ unit 03 43.000 II 800 800 80 3WL2 08-3@@32-@@@@ unit 03 56.000 000 000 3WL2 0-3@@32-@@@@ unit 03 56.000 250 250 3WL2 2-3@@32-@@@@ unit 03 56.000 600 600 3WL2 6-3@@32-@@@@ unit 03 56.000 2000 2000 3WL2 20-3@@32-@@@@ unit 03 56.000 2500 2500 3WL2 25-3@@32-@@@@ unit 03 59.000 3200 3200 3WL2 32-3@@32-@@@@ unit 03 64.000 Vertical main circuit connection I 630 630 66 3WL 06-3@@3-@@@@ unit 03 43.000 800 800 3WL 08-3@@3-@@@@ unit 03 43.000 000 000 3WL 0-3@@3-@@@@ unit 03 43.000 250 250 3WL 2-3@@3-@@@@ unit 03 43.000 600 600 3WL 6-3@@3-@@@@ unit 03 43.000 2000 2000 3WL 20-3@@3-@@@@ unit 03 43.000 II 800 800 80 3WL2 08-3@@3-@@@@ unit 03 56.000 000 000 3WL2 0-3@@3-@@@@ unit 03 56.000 250 250 3WL2 2-3@@3-@@@@ unit 03 56.000 600 600 3WL2 6-3@@3-@@@@ unit 03 56.000 2000 2000 3WL2 20-3@@3-@@@@ unit 03 56.000 2500 2500 3WL2 25-3@@3-@@@@ unit 03 59.000 3200 3200 3WL2 32-3@@3-@@@@ unit 03 64.000 4000 4000 3WL2 40-3@@3-@@@@ unit 03 85.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 2) Electronic Trip Units Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB ETU76B: Protection functions LSIN 3) NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LSING 3)5) EG ETU45B: Protection functions LSING 3)5) FG ETU76B: Protection functions LSING 3)5) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 3) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. 6) ETU5B cannot be used with 3WL air circuit breakers, size III. Siemens LV 0. 203 /

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, fixed-mounted versions Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S S Basic price A A ka kg Front main circuit connection, single hole I 630 630 66 3WL 06-3@@33-@@@@ unit 03 43.000 800 800 3WL 08-3@@33-@@@@ unit 03 43.000 000 000 3WL 0-3@@33-@@@@ unit 03 43.000 250 250 3WL 2-3@@33-@@@@ unit 03 43.000 600 600 3WL 6-3@@33-@@@@ unit 03 43.000 II 800 800 80 3WL2 08-3@@33-@@@@ unit 03 56.000 000 000 3WL2 0-3@@33-@@@@ unit 03 56.000 250 250 3WL2 2-3@@33-@@@@ unit 03 56.000 600 600 3WL2 6-3@@33-@@@@ unit 03 56.000 2000 2000 3WL2 20-3@@33-@@@@ unit 03 56.000 2500 2500 3WL2 25-3@@33-@@@@ unit 03 59.000 3200 3200 3WL2 32-3@@33-@@@@ unit 03 64.000 Front main circuit connection, double hole I 630 630 66 3WL 06-3@@34-@@@@ unit 03 43.000 800 800 3WL 08-3@@34-@@@@ unit 03 43.000 000 000 3WL 0-3@@34-@@@@ unit 03 43.000 250 250 3WL 2-3@@34-@@@@ unit 03 43.000 600 600 3WL 6-3@@34-@@@@ unit 03 43.000 2000 2000 3WL 20-3@@34-@@@@ unit 03 43.000 II 800 800 80 3WL2 08-3@@34-@@@@ unit 03 56.000 000 000 3WL2 0-3@@34-@@@@ unit 03 56.000 250 250 3WL2 2-3@@34-@@@@ unit 03 56.000 600 600 3WL2 6-3@@34-@@@@ unit 03 56.000 2000 2000 3WL2 20-3@@34-@@@@ unit 03 56.000 2500 2500 3WL2 25-3@@34-@@@@ unit 03 59.000 3200 3200 3WL2 32-3@@34-@@@@ unit 03 64.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 2) Electronic Trip Units Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB ETU76B: Protection functions LSIN 3) NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LSING 3)5) EG ETU45B: Protection functions LSING 3)5) FG ETU76B: Protection functions LSING 3)5) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 3) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. 6) ETU5B cannot be used with 3WL air circuit breakers, size III. /2 Siemens LV 0. 203

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, fixed-mounted versions Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 85/00 ka at 500 V, I cu = I cs high breaking capacity H H Basic price A A ka kg Horizontal main circuit connection I 630 630 85 3WL 06-4@@32-@@@@ unit 03 43.000 800 800 3WL 08-4@@32-@@@@ unit 03 43.000 000 000 3WL 0-4@@32-@@@@ unit 03 43.000 250 250 3WL 2-4@@32-@@@@ unit 03 43.000 600 600 3WL 6-4@@32-@@@@ unit 03 43.000 2000 2000 3WL 20-4@@32-@@@@ unit 03 43.000 II 800 800 00 3WL2 08-4@@32-@@@@ unit 03 56.000 000 000 3WL2 0-4@@32-@@@@ unit 03 56.000 250 250 3WL2 2-4@@32-@@@@ unit 03 56.000 600 600 3WL2 6-4@@32-@@@@ unit 03 56.000 2000 2000 3WL2 20-4@@32-@@@@ unit 03 56.000 2500 2500 3WL2 25-4@@32-@@@@ unit 03 59.000 3200 3200 3WL2 32-4@@32-@@@@ unit 03 64.000 III 4000 4000 00 3WL3 40-4@@32-@@@@ unit 03 82.000 5000 5000 3WL3 50-4@@32-@@@@ unit 03 82.000 Vertical main circuit connection I 630 630 85 3WL 06-4@@3-@@@@ unit 03 43.000 800 800 3WL 08-4@@3-@@@@ unit 03 43.000 000 000 3WL 0-4@@3-@@@@ unit 03 43.000 250 250 3WL 2-4@@3-@@@@ unit 03 43.000 600 600 3WL 6-4@@3-@@@@ unit 03 43.000 2000 2000 3WL 20-4@@3-@@@@ unit 03 43.000 II 800 800 00 3WL2 08-4@@3-@@@@ unit 03 56.000 000 000 3WL2 0-4@@3-@@@@ unit 03 56.000 250 250 3WL2 2-4@@3-@@@@ unit 03 56.000 600 600 3WL2 6-4@@3-@@@@ unit 03 56.000 2000 2000 3WL2 20-4@@3-@@@@ unit 03 56.000 2500 2500 3WL2 25-4@@3-@@@@ unit 03 59.000 3200 3200 3WL2 32-4@@3-@@@@ unit 03 64.000 4000 4000 3WL2 40-4@@3-@@@@ unit 03 85.000 III 4000 4000 00 3WL3 40-4@@3-@@@@ unit 03 82.000 5000 5000 3WL3 50-4@@3-@@@@ unit 03 82.000 6300 6300 3WL3 63-4@@3-@@@@ unit 03 90.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 2) Electronic Trip Units Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB ETU76B: Protection functions LSIN 3) NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LSING 3)5) EG ETU45B: Protection functions LSING 3)5) FG ETU76B: Protection functions LSING 3)5) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 3) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. 6) ETU5B cannot be used with 3WL air circuit breakers, size III. Siemens LV 0. 203 /3

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, fixed-mounted versions Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 85/00 ka at 500 V, I cu = I cs high breaking capacity H H Basic price A A ka kg Front main circuit connection, single hole II 800 800 00 3WL2 08-4@@33-@@@@ unit 03 56.000 000 000 3WL2 0-4@@33-@@@@ unit 03 56.000 250 250 3WL2 2-4@@33-@@@@ unit 03 56.000 600 600 3WL2 6-4@@33-@@@@ unit 03 56.000 2000 2000 3WL2 20-4@@33-@@@@ unit 03 56.000 2500 2500 3WL2 25-4@@33-@@@@ unit 03 59.000 3200 3200 3WL2 32-4@@33-@@@@ unit 03 64.000 III 4000 4000 00 3WL3 40-4@@33-@@@@ unit 03 82.000 Front main circuit connection, double hole I 630 630 85 3WL 06-4@@34-@@@@ unit 03 43.000 800 800 3WL 08-4@@34-@@@@ unit 03 43.000 000 000 3WL 0-4@@34-@@@@ unit 03 43.000 250 250 3WL 2-4@@34-@@@@ unit 03 43.000 600 600 3WL 6-4@@34-@@@@ unit 03 43.000 2000 2000 3WL 20-4@@34-@@@@ unit 03 43.000 II 800 800 00 3WL2 08-4@@34-@@@@ unit 03 56.000 000 000 3WL2 0-4@@34-@@@@ unit 03 56.000 250 250 3WL2 2-4@@34-@@@@ unit 03 56.000 600 600 3WL2 6-4@@34-@@@@ unit 03 56.000 2000 2000 3WL2 20-4@@34-@@@@ unit 03 56.000 2500 2500 3WL2 25-4@@34-@@@@ unit 03 59.000 3200 3200 3WL2 32-4@@34-@@@@ unit 03 64.000 III 4000 4000 00 3WL3 40-4@@34-@@@@ unit 03 82.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 2) Electronic Trip Units Versions without ground-fault protection ETU5B: Protection functions LI 6) BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB ETU76B: Protection functions LSIN 3) NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LSING 3)5) EG ETU45B: Protection functions LSING 3)5) FG ETU76B: Protection functions LSING 3)5) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 3) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. 6) ETU5B cannot be used with 3WL air circuit breakers, size III. /4 Siemens LV 0. 203

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, fixed-mounted versions Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 50 ka at 500 V, I cu = I cs very high breaking capacity C C Basic price A A ka kg Horizontal main circuit connection III 4000 4000 50 3WL3 40-5@@32-@@@@ unit 03 82.000 5000 5000 3WL3 50-5@@32-@@@@ unit 03 82.000 Vertical main circuit connection III 4000 4000 50 3WL3 40-5@@3-@@@@ unit 03 82.000 5000 5000 3WL3 50-5@@3-@@@@ unit 03 82.000 6300 6300 3WL3 63-5@@3-@@@@ unit 03 90.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 2) Electronic Trip Units Versions without ground-fault protection ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 3) EB ETU45B: Protection functions LSIN 3) FB ETU76B: Protection functions LSIN 3) NB Versions with ground-fault protection ETU27B: Protection functions LSING 4) DG ETU45B: Protection functions LSING 3)5) EG ETU45B: Protection functions LSING 3)5) FG ETU76B: Protection functions LSING 3)5) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 3) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 4) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 5) ETU45B and ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. Siemens LV 0. 203 /5

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, withdrawable versions Selection and ordering data Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N N Basic price A A ka kg Without guide frames 2) (for guide frames, see page /45 to /50) I 630 630 55 3WL 06-2@@35-@@@@ unit 03 45.000 800 800 3WL 08-2@@35-@@@@ unit 03 45.000 000 000 3WL 0-2@@35-@@@@ unit 03 45.000 250 250 3WL 2-2@@35-@@@@ unit 03 45.000 600 600 3WL 6-2@@35-@@@@ unit 03 45.000 2000 2000 3WL 20-2@@35-@@@@ unit 03 45.000 II 800 800 66 3WL2 08-2@@35-@@@@ unit 03 60.000 000 000 3WL2 0-2@@35-@@@@ unit 03 60.000 250 250 3WL2 2-2@@35-@@@@ unit 03 60.000 600 600 3WL2 6-2@@35-@@@@ unit 03 60.000 2000 2000 3WL2 20-2@@35-@@@@ unit 03 60.000 2500 2500 3WL2 25-2@@35-@@@@ unit 03 63.000 3200 3200 3WL2 32-2@@35-@@@@ unit 03 68.000 With guide frames, horizontal main circuit connection I 630 630 55 3WL 06-2@@36-@@@@ unit 03 70.000 800 800 3WL 08-2@@36-@@@@ unit 03 70.000 000 000 3WL 0-2@@36-@@@@ unit 03 70.000 250 250 3WL 2-2@@36-@@@@ unit 03 70.000 600 600 3WL 6-2@@36-@@@@ unit 03 70.000 2000 2000 3WL 20-2@@36-@@@@ unit 03 70.000 II 800 800 66 3WL2 08-2@@36-@@@@ unit 03 9.000 000 000 3WL2 0-2@@36-@@@@ unit 03 9.000 250 250 3WL2 2-2@@36-@@@@ unit 03 9.000 600 600 3WL2 6-2@@36-@@@@ unit 03 9.000 2000 2000 3WL2 20-2@@36-@@@@ unit 03 9.000 2500 2500 3WL2 25-2@@36-@@@@ unit 03 02.000 3200 3200 3WL2 32-2@@36-@@@@ unit 03 3.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 3) Electronic Trip Units Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB ETU76B: Protection functions LSIN 4) NB Versions with ground-fault protection ETU27B: Protection functions LSING 5) DG ETU45B: Protection functions LSING 4)6) EG ETU45B: Protection functions LSING 4)6) FG ETU76B: Protection functions LSING 4)6) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 4) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. /6 Siemens LV 0. 203

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, withdrawable versions Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 55/66 ka at 500 V, I cu = I cs ECO breaking capacity N N Basic price A A ka kg With guide frames, vertical main circuit connection I 630 630 55 3WL 06-2@@37-@@@@ unit 03 70.000 800 800 3WL 08-2@@37-@@@@ unit 03 70.000 000 000 3WL 0-2@@37-@@@@ unit 03 70.000 250 250 3WL 2-2@@37-@@@@ unit 03 70.000 600 600 3WL 6-2@@37-@@@@ unit 03 70.000 2000 2000 3WL 20-2@@37-@@@@ unit 03 70.000 II 800 800 66 3WL2 08-2@@37-@@@@ unit 03 9.000 000 000 3WL2 0-2@@37-@@@@ unit 03 9.000 250 250 3WL2 2-2@@37-@@@@ unit 03 9.000 600 600 3WL2 6-2@@37-@@@@ unit 03 9.000 2000 2000 3WL2 20-2@@37-@@@@ unit 03 9.000 2500 2500 3WL2 25-2@@37-@@@@ unit 03 02.000 3200 3200 3WL2 32-2@@37-@@@@ unit 03 3.000 4000 4000 3WL2 40-2@@37-@@@@ unit 03 2.000 With guide frames, connecting flanges I 630 630 55 3WL 06-2@@38-@@@@ unit 03 70.000 800 800 3WL 08-2@@38-@@@@ unit 03 70.000 000 000 3WL 0-2@@38-@@@@ unit 03 70.000 250 250 3WL 2-2@@38-@@@@ unit 03 70.000 600 600 3WL 6-2@@38-@@@@ unit 03 70.000 2000 2000 3WL 20-2@@38-@@@@ unit 03 70.000 II 800 800 66 3WL2 08-2@@38-@@@@ unit 03 9.000 000 000 3WL2 0-2@@38-@@@@ unit 03 9.000 250 250 3WL2 2-2@@38-@@@@ unit 03 9.000 600 600 3WL2 6-2@@38-@@@@ unit 03 9.000 2000 2000 3WL2 20-2@@38-@@@@ unit 03 9.000 2500 2500 3WL2 25-2@@38-@@@@ unit 03 02.000 3200 3200 3WL2 32-2@@38-@@@@ unit 03 3.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 3) Electronic Trip Units Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB ETU76B: Protection functions LSIN 4) NB Versions with ground-fault protection ETU27B: Protection functions LSING 5) DG ETU45B: Protection functions LSING 4)6) EG ETU45B: Protection functions LSING 4)6) FG ETU76B: Protection functions LSING 4)6) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 4) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. Siemens LV 0. 203 /7

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, withdrawable versions Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S S Basic price A A ka kg Without guide frames 2) (for guide frames, see page /45 to /50) I 630 630 66 3WL 06-3@@35-@@@@ unit 03 45.000 800 800 3WL 08-3@@35-@@@@ unit 03 45.000 000 000 3WL 0-3@@35-@@@@ unit 03 45.000 250 250 3WL 2-3@@35-@@@@ unit 03 45.000 600 600 3WL 6-3@@35-@@@@ unit 03 45.000 2000 2000 3WL 20-3@@35-@@@@ unit 03 45.000 II 800 800 80 3WL2 08-3@@35-@@@@ unit 03 60.000 000 000 3WL2 0-3@@35-@@@@ unit 03 60.000 250 250 3WL2 2-3@@35-@@@@ unit 03 60.000 600 600 3WL2 6-3@@35-@@@@ unit 03 60.000 2000 2000 3WL2 20-3@@35-@@@@ unit 03 60.000 2500 2500 3WL2 25-3@@35-@@@@ unit 03 63.000 3200 3200 3WL2 32-3@@35-@@@@ unit 03 68.000 With guide frames, horizontal main circuit connection I 630 630 66 3WL 06-3@@36-@@@@ unit 03 70.000 800 800 3WL 08-3@@36-@@@@ unit 03 70.000 000 000 3WL 0-3@@36-@@@@ unit 03 70.000 250 250 3WL 2-3@@36-@@@@ unit 03 70.000 600 600 3WL 6-3@@36-@@@@ unit 03 70.000 2000 2000 3WL 20-3@@36-@@@@ unit 03 70.000 II 800 800 80 3WL2 08-3@@36-@@@@ unit 03 9.000 000 000 3WL2 0-3@@36-@@@@ unit 03 9.000 250 250 3WL2 2-3@@36-@@@@ unit 03 9.000 600 600 3WL2 6-3@@36-@@@@ unit 03 9.000 2000 2000 3WL2 20-3@@36-@@@@ unit 03 9.000 2500 2500 3WL2 25-3@@36-@@@@ unit 03 02.000 3200 3200 3WL2 32-3@@36-@@@@ unit 03 3.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 3) Electronic Trip Units Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB ETU76B: Protection functions LSIN 4) NB Versions with ground-fault protection ETU27B: Protection functions LSING 5) DG ETU45B: Protection functions LSING 4)6) EG ETU45B: Protection functions LSING 4)6) FG ETU76B: Protection functions LSING 4)6) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 4) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. /8 Siemens LV 0. 203

Siemens AG 203 3WL /Non-Automatic up to 6300 A (AC), IEC 3-pole, withdrawable versions Max. rated circuit breaker current Rated current ) I n Breaking capacity DT I cu 66/80 ka at 500 V, I cu = I cs standard breaking capacity S S Basic price A A ka kg With guide frames, vertical main circuit connection I 630 630 66 3WL 06-3@@37-@@@@ unit 03 70.000 800 800 3WL 08-3@@37-@@@@ unit 03 70.000 000 000 3WL 0-3@@37-@@@@ unit 03 70.000 250 250 3WL 2-3@@37-@@@@ unit 03 70.000 600 600 3WL 6-3@@37-@@@@ unit 03 70.000 2000 2000 3WL 20-3@@37-@@@@ unit 03 70.000 II 800 800 80 3WL2 08-3@@37-@@@@ unit 03 9.000 000 000 3WL2 0-3@@37-@@@@ unit 03 9.000 250 250 3WL2 2-3@@37-@@@@ unit 03 9.000 600 600 3WL2 6-3@@37-@@@@ unit 03 9.000 2000 2000 3WL2 20-3@@37-@@@@ unit 03 9.000 2500 2500 3WL2 25-3@@37-@@@@ unit 03 02.000 3200 3200 3WL2 32-3@@37-@@@@ unit 03 3.000 4000 4000 3WL2 40-3@@37-@@@@ unit 03 2.000 With guide frames, connecting flanges I 630 630 66 3WL 06-3@@38-@@@@ unit 03 70.000 800 800 3WL 08-3@@38-@@@@ unit 03 70.000 000 000 3WL 0-3@@38-@@@@ unit 03 70.000 250 250 3WL 2-3@@38-@@@@ unit 03 70.000 600 600 3WL 6-3@@38-@@@@ unit 03 70.000 2000 2000 3WL 20-3@@38-@@@@ unit 03 70.000 II 800 800 80 3WL2 08-3@@38-@@@@ unit 03 9.000 000 000 3WL2 0-3@@38-@@@@ unit 03 9.000 250 250 3WL2 2-3@@38-@@@@ unit 03 9.000 600 600 3WL2 6-3@@38-@@@@ unit 03 9.000 2000 2000 3WL2 20-3@@38-@@@@ unit 03 9.000 2500 2500 3WL2 25-3@@38-@@@@ unit 03 02.000 3200 3200 3WL2 32-3@@38-@@@@ unit 03 3.000 Non-automatic air circuit without Electronic Trip Units AA None breakers 3) Electronic Trip Units Versions without ground-fault protection ETU5B: Protection functions LI BB ETU25B: Protection functions LSI CB ETU45B: Protection functions LSIN 4) EB ETU45B: Protection functions LSIN 4) FB ETU76B: Protection functions LSIN 4) NB Versions with ground-fault protection ETU27B: Protection functions LSING 5) DG ETU45B: Protection functions LSING 4)6) EG ETU45B: Protection functions LSING 4)6) FG ETU76B: Protection functions LSING 4)6) NG Operating mechanism, Manual operating mechanism with AA2 None auxiliary release, auxiliary switch mechanical closing, without st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO For further supplements see page /37 Additional price ) The rated current is determined by the rating plug. For the standard version, the supplied module is equal to the maximum rated current. If a lower rated current is required, adaptation by order code on page /38. 2) Z options which are installed on the guide frame are not available. 3) For permissible rated short-time current I cc and rated short-circuit making capacity I cm for non-automatic air circuit breakers see page /5. 4) Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral point of the transformer are to be ordered separately, see page /5. 5) Current transformers for protection of the N conductor are to be ordered separately, see page /5. 6) ETU45B to ETU76B with ground-fault protection module GFM AT (alarm and tripping), see page /5. Siemens LV 0. 203 /9