NEC Codes if more current shall supercede this manual

A WORD ABOUT PROPER GROUNDING

Note: For all general information, refer to Installation and Instruction Manual supplied with the operator.

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

HYDRUS INSTALLATION INSTRUCTION P/N: 3801-EOP AUTO REVERSE / AUTO STOP OPTION KIT FOR HYDRUS 2000 MAIN PANEL

Installation Tips - (Crimestopper RS00) & (Fortin EVO-ALL) For:

Electrical Components

White Light CLASSIC PEDAL KIT. Assembly Instructions WHEN YOU CAN T BUY IT BUILD IT. StewMac RARE / VINTAGE / HARD TO GET

MCC Automatic Start-Stop Microcomputer Charger Control

CM4200 and CM1000S Starter Control Module Installation Manual

Stir-Guard Operation. Instructions Design III Stir-Guard Option

Effective October 2016 Supersedes January 2014 (S )

CARM INTERNATIONAL TOWING MODULES

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

ANZI Transfer Switch and Generator Wiring Installation Addendum

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3)

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

ICON Link Flowmeter Wiring Manual

CLASSIC PEDAL KIT. Assembly Instructions WHEN YOU CAN T BUY IT BUILD IT. StewMac Monarch RARE / VINTAGE / HARD TO GET

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

3 Channel Remote Start / Keyless Entry System Installation Instructions

GIVE ME A BRAKE Light Kit 2005 / 2006 MINI Cooper/Cooper S Brake Light Modification

Fan Coil Unit (FCU) Fan Motor Control

INSTALLATION GUIDE OWNER S GUIDE

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

ZoneZ Lite Quick Start Guide

Irrigation Components International, Inc.

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

Tattletale Annunciators and Magnetic Switches

MBCM-24 MULTIPLE BATTERY CHARGING MODULE (FOR MARINE APPLICATIONS) FEATURES SPECIFICATIONS APPLICATIONS DESCRIPTION & OPERATION ORDERING INFORMATION

TIP SHEET T0937. Installation Tips For RS00/PS00 + ADS-TBSL-PL + SPDT

Lab 4: Robot Assembly

INSTALLATION INSTRUCTIONS for HI-4 DUAL FIRE MOTORCYCLE IGNITION. Part Number INTRODUCTION REMOVAL OF POINTS IGNITION TO 1977 MODELS

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer.

R & D SPECIALTIES ROTROL I USER'S MANUAL

Home Electrical Wiring. Getting the electricity from the main power lines to a location in the house

Application Engineering

TIP SHEET T0937. Installation Tips for RS00 + Passlock-sl2(4) + SPDT

3200NT Timer Service Manual

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

Ultrasonic Sensor U-B

Electro-Mechanical Swing Operator. Table of Contents

INSTALLATION GUIDE OWNER S GUIDE

SOIL MOISTURE MONITORING

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Installation Tips Crimestopper/ProStart Remote Start system + PLJX + DLRM + SPDT (for GM vehicles) T0760 v1.1 updated 2/5/14

ELECTRICAL SYSTEM RP-7

Aqua Trac Pro Wiring Manual

Grout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

1962 Wiring Diagram. The Basics Part One. by Bob Mannel

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

These instructions show how to build the Remote Controlled Fart machine Sound Kit.


How to Replace Old Style Control Manifold with New Style Manifold on AS-Series Pumps

INSTALLATION MANUAL FOR

BMS16 v cell Lithium Battery Management System

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch

Australian Wiring Instructions:

Generator Start Control Module

Excel 15 W7760A BUILDING MANAGER

R800-16PCPS DUAL REDUNDANT POWER SUPPLY FOR THE R RACK USER MANUAL

CM 5000D IN A HURRY?

Replacement Tach Board Manual

Remote Start System Installation Instructions

USERS GUIDE LO-21U LOCKOUT RELAY

Redbird LED Cardinal Stripit Kit Installation Instructions

12VPS TRAK-DT. Block Detection / Signaling Starter Package. 12 VOLT / 0.5 Amp REGULATED POWER SUPPLY. a c t i v a t i o n s e c t i o n

with Timer Override Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL 35033

Voltage Configuration Information

BX88175 Installation Instructions ToadStop II Vacuum Brake System

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual

I-BFV.KIT Butterfly Valve Gear Operator Replacement

INSTALLATION GUIDE OWNER S GUIDE

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Application Engineering

Installation Tips for your Crimestopper/ProStart Remote Start system (add-on for GM vehicles) v1.02 updated 1/16/2013

MLA Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Model 2000 Installation Guide

6500DC Dual Motor Wireless Controller Kits

Troubleshooting Bosch Proportional Valves

ECHO Enhanced Controller Hook Count Application *** Infrared Photo Sensors *** GCA 110 ECHO Controller. Version 3.5

Service Manual for Battery Control Center

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

INSTALLATION INSTRUCTIONS

Door Operator Conversion Package: Type M to PM/SSC or HPM/SSC with Board 1Ø4

EasyStart Installation Instructions for Dometic Family RV A/Cs

556L General Motors Passlock Interface Module

BSR Magic Box Digital ignition control for 4, 6, or 8 cylinder engines

7281-EA/ET INSTRUCTIONS

Transcription:

2014-17 Field Commander Lite Wiring Manual (New Large Style Board board label Comm6 FC V4.1 or V4.2 only 1 relay ) Section 1 Pages 2-6 Irrigation Pivot wiring. Section 2 Page 6 Simple on/off monitor only no control features 1

Section 1 Irrigation System Wiring Stop Only: Warning: Only 4 wires are used on these installations all unused wires must be capped or taped off individually to avoid damage to unit. Safety circuit must be tested by the installer before AND after installation is finished. Zimmatic: 1. Remove the Zimmatic brown (safety) wire from the terminal strip in the end tower box (Span Cable Side) and install our Black wire AND Red/Black wire in its place. 2. Use a wire nut to connect our Red wire to the Zimmatic brown (safety) wire that was removed from the terminal strip in step 1. Valley: 1. Remove the Valley yellow (safety) wire from the terminal strip in the end tower box (Span Cable Side) and install our Black wire AND Red/Black wire in its place. 2. Use a wire nut to connect our Red wire to the Valley yellow (safety) wire that was removed from the terminal strip in step 1. Pierce (Newer systems, example - CP600 pivots): 1. Remove the Pierce yellow (safety) wire from the terminal strip in the end tower box (Span cable wire coming from the center) and install our Black wire AND Red/Black wire in its place. 2. Use a wire nut to connect our Red wire to the Pierce yellow (safety) wire that was removed from the terminal strip in step 1. Pierce (Older systems, example - P.93 pivots): 1. Remove the Pierce brown (safety) wire from the terminal strip in the end tower box (Span cable wire coming from the center) and install our Black wire AND Red/Black wire in its place. 2. Use a wire nut to connect our Red wire to the Pierce brown (safety) wire that was removed from the terminal strip in step 1. Olson: (After 1980) 1. Remove the yellow (safety) wire from the terminal strip in the end tower box (Span Cable Side) and install our Black wire AND Red/Black wire in its place. 2. Use a wire nut to connect our Red wire to the yellow (safety) wire that was removed from the terminal strip in step 1. 2

Lockwood with 16v safety system: 1. Remove the 120v wire going to the safety transformer and connect our Black wire AND Red/Black wire in its place. 2. Use a wire nut to connect our Red wire to the wire that was removed from the transformer in step 1. 3. Install our Brown/Black wire in with the other neutral (white) wires. -see note- -note- on older Lockwood systems, the power to the safety transformer is flip-flopped depending on which direction the system is moving. On these, change step 3 to this: Install our Brown/Black wire into the other 120v terminal on the safety transformer. (with the wire that was not disturbed in step 1 or 2) Rienke And Similar Neutral Safety Systems Reinke/Neutral Safety Wiring - Note - On some Rienke pivots, the safety circuit begins at the second-to-last tower instead of at the end tower. (where the Brown Safety wire connects to the White Neutral wires) On these systems you will need to change the second-to-last tower and the end tower. In the end tower, make a jumper to connect the white neutral wires to the brown safety wire. At the second-to-last tower, locate the white wire that connects the overwatering timer contact (#10 on most) to the neutral wires on the terminal strip. Remove this white wire from the terminal strip, but leave it connected to the overwatering timer contact. Then, connect that white wire to the brown safety wire that goes out to the end tower. (this wire most likely is capped or not hooked up to anything in this second-to-last tower box) You should now have a safety circuit that starts in the end tower box where the brown wire is connected to neutral, and then travels to the second-to-last tower box on the brown wire, goes to the overwatering timer contact #10, then exits the overwatering timer on terminal #8, goes to the limit switch, then leaves the limit switch and goes to the next tower closer to the main panel. AFTER COMPLETING THIS, YOU MUST TEST THE SAFETY TO BE CERTAIN THE SYSTEM WORKS CORRECTLY. WITH THE SYSTEM RUNNING, DISCONNECT THE BROWN SAFETY WIRE FROM THE TERMINAL STRIP IN THE END TOWER BOX THIS SHOULD SAFETY THE SYSTEM OFF IF THE RE-WIRING WAS DONE CORRECTLY. ONLY AFTER THIS SAFETY TEST PASSES, THEN PROCEED TO STEP 1 OF THE PIVOT POINT WIRING BELOW. 1. Remove the Rienke brown (safety) wire from the terminal strip in the end tower box (Span Cable Side) and install our Red/Black AND Brown/Black wires in its place. - See Note at top of page - 2. Use a wire nut to connect our Red wire to the Rienke brown (safety) wire that was removed from the terminal strip in step 1. 3. Install our Black wire into the relay assembly as shown (see Picture 1 below) Relay part number - W78ARCSX-11, and Base part number 70-459-1 4. Run jumper wires from the forward and reverse on the terminal strip and install them into the relay as shown (see Picture 1 below - this gives the Pivot Point 120v on the black wire no matter which direction the pivot is moving) 5. Install our Black/Red Stripe wire into the tower box earth ground bar. 3

Picture 1 Additional Relay for Rienke (other neutral safety type pivots similar) TL pivot / Engine Shutdown - DC Powered Version: Warning: This unit has been specially built for TL pivots and/or for shutting down diesel/gas engines that use a Murphy switch system. Make sure the wires inside the field commander are in the correct terminals: Yellow Wire DC/SOL Terminal (terminal 2 of the large green 6 position terminal strip (J2)) Yellow/Black Wire Any terminal marked GND of the large green 24 or 6 position terminal strips Red Wire Terminal 3 of the 24 position terminal strip (Stop relay Normally Open) Red/Black Terminal 5 of the 24 position terminal strip (Stop relay Common) Mounting the unit at the Engine, Center of pivot, or by running wire out to the first tower: 1. Connect Yellow/Black to Ground 2. Connect Yellow to 7-28 VDC that is only on when the engine is running. 3. Connect Red/Black to Ground 4. Connect Red Wire to S terminal of Murphy switch (this will ground the Murphy switch and shut down the engine/pivot when a command is sent via the web) 4

Using on end tower of TL pivot with Precision Point Control: (24 volt controls at the end tower) 1 In the end tower box, connect our Red/Black wire and our Yellow/Black wire to the Ground Bus in picture 1 2 In the end tower box, connect our Yellow wire to a new diode pair (from the TL kit available from AgSense) attached to FWD and REV as shown in picture 1 (MUST ADD NEW DIODE PAIR existing diode pair is to run the speed sensor only do not modify or remove the original pair if your system has them just add the two new diodes to the FWD and REV terminals that the original diode pair is already in.) 3 In the end tower box, connect our Red wire to an unused span cable wire that goes back to the center of the pivot to the T&L Point Control Panel. 4 At the center of the pivot, the span cable wire that was used in step 3 must be connected correctly to shut off the pivot one of these two ways depending on how the Point Control Panel is powered: A. On pivots being powered from the 12v battery of the diesel/gas engine, connect the wire from step 3 to terminal 11 in the T&L Point Control Panel (if the Murphy switch 117 s terminal is wired into the Point Control Panel) - If the Murphy switch is not wired into the Point Control Panel, you must run the wire from step 3 directly to the Murphy 117 s terminal. B. On pivots being powered by AC, an isolation relay must be installed in the Point Control Panel. This relay must be a 24v DC Coil relay that is Normally Open. a. Connect one terminal of the relay coil to the wire from step 3. b. Connect the other terminal of the relay coil to terminal 10 in the Point Control Panel (24v DC) c. Next, if the Murphy 117 is wired into the Point Control Panel, connect the Common terminal of the Isolation relay to terminal 12 in the Point Control Panel (AC Neutral). Then connect the Normally Open terminal of the isolation relay to terminal 11 in the Point Control panel (Murphy 117 s ). d. If the Murphy 117 is not wired into the Point Control Panel, you must run wire from terminal 11 in the Point Control panel to the Murphy 117 s terminal, and run wire from terminal 12 in the Point Control panel to AC Neutral in the electric panel that the Murphy switch is in. 5

Section 3 Simple Power On/Off Monitor Wiring: This is only to monitor if Power to a device is on or off there are no controls. 120v AC Device Monitor system: Brown/Black Neutral Black Wire 120v AC OR 7-40v DC Device Monitor system: Yellow/Black Ground Yellow 7-40v DC 6

Power Requirements for these units: DC Powered Unit 7-40V DC: At 12v DC: 1.0A MAX 0.1A - 0.5A during normal operation 120vAC Powered Unit: At 120v AC: 0.25A MAX 0.05A - 0.15A during normal operation The above numbers are the current required for our unit to operate. Below is the current the relays in our box can control: On both AC and DC units, each relay can handle a peak max of 5A, 3A constant (at a max voltage of 120vAC, or 30vDC). 7