FWT-200 OPTI-CHROMIC READER SYSTEM

Similar documents
EPAS Desktop Pro Software User Manual

Hardware installation guide

Cannondale Diagnostic Tool Manual

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software

Issue 2.0 December EPAS Midi User Manual EPAS35

PSC1-003 Programmable Signal Calibrator

RDS. For Windows TORSION SPRING CALCULATOR For ROLLING DOORS Version 4 REFERENCE MANUAL

Version 1.0 Copyright DC-RPM-iBox User Manual

Service & Maintenance

PRESSURE SENSOR INSTRUCTIONS

Network Installation. July 2008 CONTENTS

CurveMaker HD v1.0 2Ki Programmable Ignition programming software

Atomic Absorption Spectroscopy

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

Introduction. Figure 1: Labeled picture of the Instron 3367 load frame.

Huf Group. Your Preferred Partner for Tire Pressure Monitoring Systems. IntelliSens App

MetaXpress PowerCore System Installation and User Guide

R and R Meritor WABCO Enhanced Easy-Stop Trailer ABS Replacement Kits for Easy-Stop ECU/Modulator Valve Assembly Part Number

Before you begin using your Allegro CX. Complete all of the steps outlined in each section of this guide.

SPEEDKEY KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 9. GEM e2, e4, e6, el XD

GPS Steering System Installation Manual

Safety Considerations

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A

Operating Instructions Operating Instructions. HEKA testing lane UNIVERS "TX" 4cm above floor

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

AOYUE INT. Advanced Repairing System NT 701A++ INSTRUCTION MANUAL

Model 2500 Horsepower Computer System User Manual

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

Error Code List for ecash & Nanocash

Introduction Safety precautions for connections... 3 Series 3700 documentation... 4 Model 3732 overview... 5 Accessories...

IBM CMM Quick Reference Guide

HP DesignJet 430 HP DesignJet 450C HP DesignJet 455CA Printers. Service Manual

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

USER S GUIDE LandAirSea 7100 Real Time GPS Tracking System

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

Solution / Instructions

XC Instrumentation System Owner s Manual Revision /05/06

TRW Commercial Steering Torque Overlay Diagnostic Tool

4.1 Flow Rate Verification and Adjustment

Table of Contents 1. INTRODUCTION GENERAL INFORMATION-ABOUT OBDII/EOBD PRODUCT DESCRIPTIONS OPERATIONS...11

CenterLine Filter Wheel

Installation Instructions for: EMS P/N Ford Mustang 5.0L

Motorized Electric Latch Retraction

AR2000 Rheometer: Instructions

Advanced User Manual

MAGPOWR Spyder-Plus-S1 Tension Control

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

Introduction. E-Trac Xchange is versatile and easy to use, so make the most of your E-Trac with this great new feature. Enjoy!

PRSalpha Air Drill (Double Valve)

Hand Held Pull Tester Instruction Manual Order No

T H E U L T I M A T E L A S E R D E F E N S E S Y S T E M

DFE PARTS LIST INSTALLATION INSTRUCTIONS PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Huf Group. Your Preferred Partner for Tire Pressure Monitoring Systems

SA Series Tape Feeder

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.

ZT-USB Series User Manual

Customer User Guide. ComTrac CUSTOMER USER GUIDE VERSION 0.1

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

DriveRight VSS Installation Guide

IDENTIFICATION OF FUEL INJECTION CONTROL SYSTEM IN A GDI ENGINE

Online Capacity Tester MK70 User and PC-Software Manual

Flue Gas Analyzer IMR 1100F

Simulating Trucks in CORSIM

PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents

Operating Instructions EVG620 Aligner

User Manual. Engine and Tank Monitoring Firmware version 1.00e for Text Display YDTD-20N

Pulsar EXtreme 2200C / 3200C

Thermo Scientific APEX 500 Rx Metal Detector User s Guide. REC 4345 Rev B Part number English

OEM TM-50 Quick Start Guide

Indian Speedometer and Body Control Module Service Tool Users Guide

IBM UPS Extend Run Battery Pack Operation and Setup Guide

Overview of operation modes

Universal Wireless Dashboard Y-Dash + Android App Y-Dash GT. User Manual Firmware version 1.6 Software version 2.28 Hardware version 1.

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

Model DS7060 Handrail Scale. User Manual

INTELLIQUILTER INSTALLATION ON PRODIGY VERSION

Controller Ground (dual black 12awg) should be connected to chassis ground as close as possible to the battery.

Genesys 20 Calibration and Maintenance

STRESS-TEK, INC S. 194 th Street Kent, WA June 2011 Stress-Tek, Inc. Doc Rev A

READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING TC-6 TC-15 TC Fax

TachoDrive key + TachoDrive Express software

Educational Robot. Revision 2.0

INSTALLATION MANUAL AP60B INSTALLATION MANUAL

for Autonomous Operation Quick User s Guide SOR SOR Quick User s Guide for Autonomous Operation Rev 1

ELD DRIVER GUIDE June 21, 2018

ROW PRO DOWN PRESSURE

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

TECHNICAL BULLETIN No:

Adaptronic esel020 Select ECU for Nissan S13 240SX (KA24DE) / RNN14 GTiR / SR20VE

WANHAO Duplicator i3. User Manual V1.2. Wanhao USA

Manifold w/ Needle Valve Instruction Manual

INDEX. 1.Safety Precautions and Warnings...3

Agilent G4236A 2D-LC Valve Installation Guide

WindLab TM Wind Turbine Power System Sample Laboratory Procedure Manual

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Transcription:

FWT-200 OPTI-CHROMIC READER SYSTEM User s Manual Covers Installation and Windows software for ISA and PCI cards September, 2002 Far West Technology, Inc. 330 South Kellogg Ave. Suite D Goleta, CA 93117 USA

INTRODUCTION The FWT-200 Opti-Chromic Reader is a computer controlled densitometer designed to read FWT-70 Opti- Chromic Detectors. The complete reader system consists of a computer (IBM PC\XT\AT compatible), the reader head, an ADC card for the computer (ISA and PCI versions available), a cable to connect the head to the card, and software. HARDWARE INSTALLATION Dedicated Computer We recommend that you use a dedicated computer for the Model 200. We have found that users who network, run multiple programs, or use inexpensive computers often have poor results with the Model 200. If you do have problems, stop multitasking, shut down all concurrent programs, remove the network connection, remove excess hardware and/or try a better quality computer. ADC Board (ISA Version) Before installing the ADC board in the computer you need to note the base address of the board. If you have other expansion cards in the computer you should also check that the base address does not conflict with the address of the other cards. If necessary, the base address may be altered by changing the DIP switch on the ADC card. To determine the base address of the card examine the DIP switch settings and the numbers printed on the printed circuit board (not the numbers on the DIP switch housing). The card is originally set up with an address of 0x300, which has switches 3 and 4 off and switches 5-9 on. The base address of the ADC card may be changed to provide a range of selections to the user. Table 1 gives the decimal and hexadecimal values and the position of each switch. Note the base address of the card so that this may be specified in the configuration file (DOS software version 1.x) or in the setup dialog box (version 2.x). The windows version allows you to specify the base address by showing how the DIP switches are set. Consult your computer manual for details on installing an expansion card in your computer. Most installations are as follows: First make sure that the computer is turned off and unplugged. Next open the case to allow access to the expansion slots. Choose an appropriate empty slot for the card. Remove the retaining bracket, being careful not to drop the screw in the computer. Firmly insert the card in the slot and screw the bracket to the chassis. Replace the case. ADC Board (PCI Version) See the PCI-DAS08 User s Manual for installation instructions for the PCI version of the ADC card. IMPORTANT: The PCI Board and supporting software should be installed before the FWT200 software is installed. Then the InstaCal program should be run and the PCI-DAS08 board added to the list of recognized boards. Connecting the Head to the Card Before connecting the head to the card you should make sure that the computer is turned off. Connect one end of the supplied cable to the card and the other end to the reader head (the two ends are interchangeable for the ISA card; the cable for connecting to a PCI card has different connectors on the two ends and is FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 1

different than the PCI cable for the FWT-100). Securely fasten them by tightening the screws on the connectors. Table 1 - FWT-300 Computer ADC Card Base Address Selection NOTE: Addresses 000 to 0FF hex used by internal I/O Address DIP Switch Settings Dec Hex 9 8 7 6 5 4 3 256 100 on on on on on off on 264 108 off on on on on off on 272 110 on off on on on off on 280 118 off off on on on off on 288 120 on on off on on off on 296 128 off on off on on off on 304 130 on off off on on off on 312 138 off off off on on off on 320 140 on on on off on off on 328 148 off on on off on off on 336 150 on off on off on off on 344 158 off off on off on off on 352 160 on on off off on off on 360 168 off on off off on off on 368 170 on off off off on off on 376 178 off off off off on off on 384 180 on on on on off off on 392 188 off on on on off off on 400 190 on off on on off off on 408 198 off off on on off off on 416 1A0 on on off on off off on 424 1A8 off on off on off off on 432 1B0 on off off on off off on 440 1B8 off off off on off off on 448 1C0 on on on off off off on 456 1C8 off on on off off off on 464 1D0 on off on off off off on 472 1D8 off off on off off off on 480 1E0 on on off off off off on 488 1E8 off on off off off off on 496 1F0 on off off off off off on 504 1F8 off off off off off off on 512 200 Do not use - Reserved for system 520 208 Do not use - Reserved for system 528 210 on off on on on on off 536 218 off off on on on on off 544 220 on on off on on on off 552 228 off on off on on on off 560 230 on off off on on on off 568 238 off off off on on on off 576 240 on on on off on on off 584 248 off on on off on on off 592 250 on off on off on on off 600 258 off off on off on on off 608 260 on on off off on on off 616 268 off on off off on on off 624 270 on off off off on on off FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 2

Address DIP Switch Settings Dec Hex 9 8 7 6 5 4 3 632 278 Do not use - Reserved for system 640 280 on on on on off on off 648 288 off on on on off on off 656 290 on off on on off on off 664 298 off off on on off on off 672 2A0 on on off on off on off 680 2A8 off on off on off on off 688 2B0 on off off on off on off 696 2B8 off off off on off on off 704 2C0 on on on off off on off 712 2C8 off on on off off on off 720 2D0 on off on off off on off 728 2D8 off off on off off on off 736 2E0 on on off off off on off 744 2E8 off on off off off on off 752 2F0 on off off off off on off 760 2F8 Do not use - Reserved for system 768 300 on on on on on off off DEFAULT SETTING 776 308 off on on on on off off 784 310 on off on on on off off 792 318 off off on on on off off 800 320 Do not use - Reserved for system 808 328 Do not use - Reserved for system 816 330 on off off on on off off 824 338 off off off on on off off 832 340 on on on off on off off 840 348 off on on off on off off 848 350 on off on off on off off 856 358 off off on off on off off 864 360 on on off off on off off 872 368 off on off off on off off 880 370 on off off off on off off 888 378 Do not use - Reserved for system 896 380 on on on on off off off 904 388 off on on on off off off 912 390 on off on on off off off 920 398 off off on on off off off 928 3A0 on on off on off off off 936 3A8 off on off on off off off 944 3B0 Do not use - Reserved for system 952 3B8 Do not use - Reserved for system 960 3C0 on on on off off off off 968 3C8 off on on off off off off 976 3D0 on off on off off off off 984 3D8 off off on off off off off 992 3E0 on on off off off off off 1000 3E8 Do not use - Reserved for system 1008 3F0 Do not use - Reserved for system 1016 3F8 Do not use - Reserved for system FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 3

Lamp Replacement The FWT-200 comes with a lamp installed and one spare lamp taped to the inside of the lamp access cover. When the lamp burns out or becomes too dim you should replace it. To replace the lamp first remove the access cover by unscrewing the black thumb screw on the back of the reader head. Remove the access cover and, from the bottom of the reader, unscrew the black thumb screw which holds the lamp in place. Disconnect the lamp from the circuit board by pulling the connector off the board. Remove the lamp and discard it. Insert the new lamp into the holder as far as it will go and tighten the thumb screw just enough to prevent the lamp from moving. Do not over tighten the screw or you may damage the lamp's housing. Attach the lamp's connector to the circuit board. Replace the access cover. Dosimeter Well The FWT-200 has a dosimeter well that accepts FWT-70 Opti-Chromic dosimeters and FWT-160 Neutral Density filters. The lid to the well should be closed whenever you take a reading (zero, dosimeter or filter). Dosimeters are placed in the light path, which is parallel to the front of the reader. A neutral density filter is inserted in the slot on the right side of the well. Drape the filter s identification tab to the right so it will lay between the top of the reader housing and the well lid rather than being draped into the well. Software Version 1.x (for DOS) This software is located in the DOS folder on the CD-ROM. Information on the nstallation and use of the FWT- 200 software, v.1.x for DOS may be found in the file MANUAL1.DOC or Manual.pdf in that folder. Software version 2.x (for Windows) Version 2.x of the FWT-200 software is an applet that communicates with other programs (such as a spreadsheet, database, or word processor) through dynamic data exchange (DDE) links. The applet displays the absorbance, wavelength and any error message, and makes these available to other programs. Installation Insert the CD-ROM into your computer. Use Windows Explorer (or similar) to navigate to the appropriate ISA or PCI directory on the CD-ROM drive. Double-click the setup.exe file to run the setup. Follow the instructions in the setup program to install the software. Running the Software From Window s Start Program menu select FWT200 or FWT200PCI to run the appropriate software for your card. The file will be in the Far West Technology folder if you accepted the default folder during installation. The first time the software is run on a computer it will display the Port Address Setup (or PCI Card Setup) dialog box. In the PCI software select the PCI-DAS08 card from the pull-down list and click the accept button. In the ISA software specify the port address either by entering the address (in hexadecimal) into the address box or by clicking the DIP switch display to indicate how the switches are set on the card. You may then test the address before accepting it. The main display for the software is a box with the menus, wavelength being analyzed and absorbance reading. The only option on the File menu allows you to Exit the program. The only active option on the Help menu will give you information About the software, including the version number. FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 4

The Setup menu has five options. Shut Motor Off or Turn Motor On In order to increase the life of the motor you may shut the motor off if you do not plan to use the reader for an extended period of time. Once you shut the motor off the menu option changes so you may turn the motor on and continue reading. NOTE: the motor should automatically stop anytime you exit the program. Neutral Density Filter Check allows you to verify reader performance by analyzing neutral density filters (NDF). When you select this option a dialog box will appear. With the dosimeter well empty and the lid closed, you should click on the zero button. Zeroing will enable the three filter buttons. You may then place any filter into the reader and click the appropriate button to take readings of that filter. Do this for one or more of the filters. The absorbances will display on the screen and are available through a DDE link (see DDE Links section below). The software uses a calibration factor to adjust the ADC readings to absorbance readings. This check will give you the information you need to adjust this calibration factor, if desired (you may also treat the difference between the observed NDF values and the certified values as a bias of the reader). The default calibration factor is 1.9. The calibration factor may be changed using the fwtgain.exe program in the support directory of the CD-ROM. Start the program, enter the reader s serial number. The program will display the current (or default) value for the reader. You may change the value or exit the program without changing the value. Decreasing the gain will decrease the absorbance readings; thus if your NDF readings average about 2% high you would adjust the gain down 2%. Zero allows you to zero the absorbance reading. The reading may change over time a slow drift in zero is normal. Wavelength allows you to select for which wavelength(s) to display absorbance data. Port brings up the Port Address Setup dialog box, discussed above. DDE Links Dynamic Data Exchange (DDE) links allow data to be transferred from one program to another. The FWT200 program allows other programs to access the absorbance reading for a wavelength. The communication is established with a link source of fwt200 (for the ISA version of the program) or fwt200pci (for the PCI version), a topic of data, and an items of a1, a2 and a3 for absorbance at the primary (typically 600 nm), secondary (typically 656 nm) and reference (typically 750 nm) wavelengths, respectively; lbla1, lbla2 and lbla3 are the primary, secondary and reference wavelengths, respectively (for example, 600 nm, 656 nm and 750 nm ); na1, na2, na3, for the absorbances of neutral density filter A (the light filter) at the primary, secondary and reference wavelengths, respectively; nb1, nb2, nb3, for the absorbances of neutral density filter B (the medium filter) at the primary, secondary and reference wavelengths, respectively; nc1, nc2, nc3, for the absorbances of neutral density filter C (the dark filter) at the primary, secondary and reference wavelengths, respectively; wl, for the wavelength; wl is 1 if only the primary wavelength is displayed, it is 2 if only the secondary wavelength is displayed, and it is 3 if both wavelengths are displayed. FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 5

Consult the software manual for your spreadsheet, database or word processor to determine its capabilities for DDE communication and the appropriate syntax. In Microsoft Excel the syntax is: =fwt200 data!a1 to have the cell s contents reflect the absorbance reading at the primary wavelength using an ISA card. The pipe character,, separates the program name and topic; an exclamation point,!, separates the topic and item. The fwt200.xls spreadsheet in the support directory on the distribution CD-ROM illustrates how the data may be accessed, how a dose may be determined from default initial absorbance and a lookup table, and how to copy the information as data (rather than links) into another area of the spreadsheet. Troubleshooting If you are having problems with the FWT200 reader or software please check the following: 1. Reader is securely fastened to the ADC card using the cable supplied by Far West Technology. 2. Computer is connected to an appropriate stable power supply and is turned on. We encourage the use of a quality computer, surge protection and any line filter needed to provide the computer with a stable voltage input. 3. The lamp is on. If there is no light first check items 1 and 2 above, then try replacing the lamp, per the directions in the Lamp Replacement section above. 4. The reader s optical path is clear. Be sure there are no dosimeters in the reader. If the above actions do not solve your problem you may check our website (www.fwt.com) for additional information on troubleshooting or contact us at: Far West Technology, Inc. 330 S Kellogg Ave, Suite D Goleta, CA 93117 USA Tel.: +1 (805) 964-3615 Fax: +1 (805) 964-3162 E-mail: info@fwt.com When contacting us, please indicate the following: 1. The version of the FWT200 software you are using (see the Help About dialog box) and whether you are using a PCI or ISA card. 2. The version of Windows you are using. 3. The serial number of your reader. 4. Contact information, including contact name, company, location (include country if outside the USA) fax number and e-mail address. 5. A complete description of the problem you are experiencing. FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 6