FL-500P Floor Box. Metal Products Group. Scrub water approved for carpet, tile, and wood floors! SPECIFICATIONS DESCRIPTION

Similar documents
FL-540P Floor Box. Metal Products Group SPECIFICATIONS DESCRIPTION

FL-640P Floor Box. Metal Products Group SPECIFICATIONS DESCRIPTION

Resource RFB Series Floor Boxes

Resource RFB Series Floor Boxes

ED923R7 Updated April 2011 For latest specs visit

COMBINATION COVER & CARPET FLANGE

Flush Service Floor Boxes

Recessed Floor Boxes for Concrete & Wood Floors

WIREMOLD Service Fittings

WIREMOLD FLOOR BOXES EVOLUTION SERIES BOX. FLOOR TYPES.

Floor Boxes. Flush Power and Communications. FPT4 Series Poke-Through: 4 Power and Communications. FPT4 Series Poke-Through: Covers

Convention Center Series Products

FIRE CLASSIFIED FLOOR BOXES Omnibox Series Floor Boxes

n Flush activations for single-, double-, and triple-duct runs

TRUCK BOXES. Commercial Grade Truck Equipment

HUBBELL SystemOne Recessed Fire-Rated Poke-Throughs

Residential LEW ELECTRIC FITTINGS COMPANY R C P. serving the electrical industry since Series RRPSeries SWBSeries RCFBSeries

Walkerflex Modular Wiring System

Modulink. Wiremold 880MP Series Nonmetallic Floor Boxes. 880 Series Floor Boxes

MODELS LCE/LCS, L2E/L2S, L3E/L3S

Evolution Series Poke-Thru Devices

WIREMOLD Ratchet-Pro Series Floor Boxes

880W Series. Rectangular Floor Boxes for Wood Floors. Floor Boxes for Wood Floors

CT Metering. CT Metering. Meter Mounting Equipment

Cable & Wire Management

F E A T U R E S & B E N E F I T S. ED755R13 Updated September 2011 For latest specs visit

Flanges & Fittings. 2.1 Chain Clamp Components & Hardware. 2.2 NW Flanges & Fittings ISO Flanges & Fittings. 2.4 ASA Flanges & Fittings

DATA SHEET Stage Pocket Data Spec Sheet Revision: 1A

CLAMP-CLOSED PIPE-STL BLK 1/2" (540) CLAMP-GROUNDING,PIPE CLAMP-CLOSED CLAMP-CLOSED

SV321 & SV Way Normally Closed and Normally Open Pilot Operated Solenoid Valves

Features and Benefits

2018 Product Catalog

WIREMOLD Fire Classified Floor Boxes

FloorPort Series. Redesigned Service Fittings Supply the Versatile Workstation. Service Fittings

MODELS GED/GSD, DFE/DFS, DDE/DDS DIRECT DRIVE SIDEWALL PROPELLER FANS WALL HOUSING MOUNTING OPTIONS WALL HOUSING

ACCESSORIES QUICK CONNECTOR COVER BRACKETS BARRIER CUSTOM TEES & CROSSES

The newly redesigned FloorPort

WORKBOOK/PRICE LIST JULy 2011

Floor Boxes. Access Floor Modules

PRODUCT BROCHURE. Steel City solid brass and aluminum floor box covers

SECTION A-A

INCANDESCENT LAMPHOLDERS SECTION H INCANDESCENT LAMPHOLDERS

Headlight Module Conversion Kit

Electrical Accessories

W94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection

MODIFICATIONS/ACCESSORIES

PRODUCT BROCHURE. Steel City fire-rated poke-through systems

MODULAR TELEPHONE JACKS

Cover. Finishes/Colors/ Powder Coat FINISH PLASTIC METAL

HOOK UP LAYOUT FOR HEAT GENERATION AND FUEL TANK SYSTEM

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

Fuse Blocks and Clips

Poke-Thru Devices from Wiremold/ Legrand provide

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB

5-1/2 INCH L X 4-1/8 INCH W X 6 INCH H

MOUNTING ARRANGEMENT OPTIONS OVERVIEW

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS

Disconnect Enclosures

A&N CORPORATION High Vacuum Manufacturers Since 1965 TRI-SEAL

ACCESSORIES 204 ACCESSORIES

Air and Vacuum Sewer Valves. Stainless Steel Trim Standard. Short Air & Vacuum Sewer Series

WALL MOUNTED GAS BOILER. Models OLSSC-050 OLSSC-075 OLSSC-100 OLSSC-150 OLSSC-200 PARTS, KITS & OPTIONAL ACCESSORIES

Assembly and Modular Table Power System Installation Instructions for Train Tables

AMPLIFIER A OR B SELECTOR

WALL MOUNTED GAS BOILER. Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 PARTS, KITS & OPTIONAL ACCESSORIES

Server & Network Enclosures

ISO 9001 : Full Port Check Valves. Male NPT, Plain & Grooved End Lowest Pressure Drop. Maximizing the Flow

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

Bulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C)

MEMSTYLE. SPECTRA Modules range TECHNICAL INFORMATION

Table of Contents. How to Select a Winch

RELOC Modular Wiring Specialty Lighting and Power Systems

Tubing Cutter for 1/16" Stainless Steel Tubing

DT Family. Contents. DT Family Overview 18 DTV Series 28. Part Numbering System 18 DTMH Series 29. Dimensions 19 DTMN Series 30

CASRE Disconnect Arm Retro Instructions 2/23/2016

2015 PRODUCTS & PRICES

DMC-500 TM. DC Motor Drive Control. Operation / Installation Manual Manual Part Number: S8M5003 Date: August 11, Computer Weld Technology, Inc.

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

HEAVY DUTY ADAPTABLE CART

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

ESW/PESW. Non-Combination Starters

Harrow Option Item Part No. Description Item Part No. Description

Designer Casters Capacities to 175 lbs.

1000 SERIES SURFACE MOUNTED CLOSERS

Nor-Cal Products. where technology takes shape. vacuum products catalog

Toyota Tacoma TB TG

Electrical Safety World Video Episode 1 Electricity Basics

CONDENSING GAS BOILER Models 075 & 100

EMERALD CUBICLE COLLECTION. Installation Guide

Standards IEC IEC 529 Rated IP66-9 EN EN Mounting frame: removable predrilled reinforced DIN-rails

Adapt II Commercial desking

Cat Description Finish. 1 Hole Plug Gray /4 Hole Plug White /4 Hole Plug Bronze /4 Hole Plug Gray 10 30

Academic Technology Classroom and Lab Product & Placement Standards

6 CAB & SEATS. Quality Suspension Seat. Quality Suspension Seat. Quality Suspension Seat. Quality Suspension Seat. Quality Suspension Seat

TWD-U Die cast body Urethane soft tread for hard floors 50mm (2 ) & 60mm. TWH & TWH-U Heavy duty nylon body Hard or urethane tread 75mm, 100mm, 125mm

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM

PICKUP & SERVICE BODY DRAWERS MODULAR WORK TRUCK INTERIORS MAXIMUM EFFICIENCY ENHANCED ORGANIZATION INCREASED SAFETY

INSTRUCTION SHEET. Diffused Metal Halide Kit for Vertical Mast MLTs. Overview. Models Affected. Kit Components. Recommended Tools WARNING WARNING

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

4412HS Wway 4X4X12 N1 HC Lay-In. Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information

Transcription:

FL-500P Floor ox Metal Products Group FL-500P Floor ox 11-gauge steel temporary construction cover included 11-gauge finished steel cover with choice of carpet edging Mitered brass or aluminum carpet edging.5 or.25 high Stainless steel compression latches Lift-off full access door Leveling feet Scrub water approved for carpet, tile, and wood floors! DESRIPTION Our FL-500P Floor oxes combine rugged construction and an elegant design for use in carpet, tile or wood covered floors over poured concrete applications. This makes it the perfect floor box for ballrooms, convention spaces and high traffic areas. There is ample compartment room to accommodate power, audio, video, telecommunications and data in one elegant and practical box. There are a variety of covers to choose from. Options include integrated carpet edging, flat covers for noncarpeted, bare floor applications and different finishes. The lift-off section of the cover allows full access to internal connector plates and stored cables. The hinged cable exit door flips back to allow the cover to remain in place after connections are made and cables are routed through it. The 0.25 and 0.5 raised edge style covers are UL scrub water approved. The innovation continues to the transformable back box. The FL-500P s internal brackets can be arranged to provide numerous options for both high and low voltage standard gang openings making it the most flexible and easiest to install floor box available. Removable center dividers make passing cables through the various compartments a snap. Integral Easy Pour leveling feet are standard on all of the back boxes. Several box depths are available. The 4 through 10 deep boxes are UL listed. The unit includes all the necessary internal plates and brackets to make pre and post pour compartment changes quick and easy. Using this system, both high and low voltage gang configurations along with line voltage compartment isolation can be implemented on the fly. This makes just about any cabling/ connector scenario possible. SPEIFITIONS Size: ox: 10 x 12 x depth over: 10.5 x 12.5 x.125 Edging: Height:.25 or.5 Material: rass or luminum Flat overs also available Weight: 16 lbs. KNOKOUT SPEIFITIONS FL-500P-2.25 Qty/ox 1/2 / 3/4 oncentric 12 FL-500P-3 Qty/ox 1/2 8 1.00 / 1-1/4 oncentric 4 FL-500P-4 Qty/ox 3/4 8 1.00 / 1-1/4 oncentric 4 1.00 / 1-1/4 / 1-1/2 oncentric 8 FL-500P-6 thru 10 Qty/ox 3/4 8 1.00 / 1-1/4 / 1-1/2 oncentric 12 LIT1047F

FL-500P Floor ox FL-500P-6 6 Deep K OX DETIL DRWINGS FL-500P-2.25 2.25 Deep PLTE ONFIGURTIONS The box contains two identical brackets and either side can be configured as shown using the included parts. Plate onfiguration 1-2 Plate onfiguration 1-3 Plate onfiguration 2-2 RKET LNK RKET 6.08 Plate onfiguration 3-1 2.33 FL-500P-3 3 Deep Plate onfiguration 4 FL-500P-8 8 Deep FL-500P TRNSFORMLE KOX 8.08 2.93 FL-500P-4 4 Deep GNG PLTE S dd and remove as needed to form a multitude of gang arrangement possibilities FL-500P-10 10 Deep OMPRTMENT S Remove or arrange as needed to isolate compartments WRNING: Must be used on a compartment where line voltage wiring is present 4.08 10.08 ENTER S Remove to run cables across compartments

FL-500P Floor ox FL-500P-6 6 Deep K OX DETIL DRWINGS FL-500P-2.25 2.25 Deep PLTE ONFIGURTIONS The box contains two identical brackets and either side can be configured as shown using the included parts. Plate onfiguration 1-2 Plate onfiguration 1-3 Plate onfiguration 2-2 RKET LNK RKET 6.08 Plate onfiguration 3-1 2.33 FL-500P-3 3 Deep Plate onfiguration 4 FL-500P-8 8 Deep FL-500P TRNSFORMLE KOX 8.08 2.93 FL-500P-4 4 Deep GNG PLTE S dd and remove as needed to form a multitude of gang arrangement possibilities FL-500P-10 10 Deep OMPRTMENT S Remove or arrange as needed to isolate compartments WRNING: Must be used on a compartment where line voltage wiring is present 4.08 10.08 ENTER S Remove to run cables across compartments

FL-500P Floor ox FL-500P-6 6 Deep K OX DETIL DRWINGS FL-500P-2.25 2.25 Deep PLTE ONFIGURTIONS The box contains two identical brackets and either side can be configured as shown using the included parts. Plate onfiguration 1-2 Plate onfiguration 1-3 Plate onfiguration 2-2 RKET LNK RKET 6.08 Plate onfiguration 3-1 2.33 FL-500P-3 3 Deep Plate onfiguration 4 FL-500P-8 8 Deep FL-500P TRNSFORMLE KOX 8.08 2.93 FL-500P-4 4 Deep GNG PLTE S dd and remove as needed to form a multitude of gang arrangement possibilities FL-500P-10 10 Deep OMPRTMENT S Remove or arrange as needed to isolate compartments WRNING: Must be used on a compartment where line voltage wiring is present 4.08 10.08 ENTER S Remove to run cables across compartments

OVER DETIL DRWINGS STYLE 1 1/4 HIGH STYLE 2 H FLNGE J 1/4 HIGH FLNGE H J SETION H-H (ENLRGED) SETION J-J (ENLRGED) 10.50 STYLE 3 1/2 HIGH STYLE 4 K FLNGE 10.50 L 1/4 HIGH FLNGE K L SETION K-K (ENLRGED) SETION L-L (ENLRGED) 10.50 10.50 STYLE 5 M STYLE MODEL NUMER DESRIPTION 1 1 2 2 3 3 4 4 FL-500P-SQ- FL-500P-SSQ- FL-500P-LP- FL-500P-SLP- FL-500P-- FL-500P-S- FL-500P-PLP-GRY- FL-500P-PLP-LY- 1/4" RSS FLNGE 1/4" LUMINUM FLNGE 1/4" EVELED RSS FLNGE 1/4" EVELED LUMINUM FLNGE 1/2" RSS FLNGE 1/2" LUMINUM FLNGE 1/4" LUMINUM FLNGE PINTED GRY 1/4" LUMINUM FLNGE PINTED LY 4 FL-500P-PLP-LK- 1/4" LUMINUM FLNGE PINTED LK 5 5 5 FL-500P-LK- FL-500P-OK- FL-500P-SS NO FLNGE, LK SNDTEX NO FLNGE, OK SNDTEX NO FLNGE, STINLESS STEEL 10.50 M SETION M-M

OVER OPTIONS FL-500P-SS- FL-500P-LK- FL-500P-- FL-500P-LP- FL-500P-OK- FL-500P-S- FL-500P-SLP- FL-500P-SSQ- Floor ox overs and ack oxes ordering information FL-500P Requires ordering over and ack ox separately Part # Description overs - UL Scrub Water Rated for Tile and arpet Installations FL-500P-- over With 1/2" rass arpet Flange (Lift off door) FL-500P-LP- over With 1/4" eveled rass arpet Flange (Lift off door) FL-500P-SQ- over With 1/4" Square rass Flange (Lift off door) FL-500P-S- over With 1/2" luminum arpet Flange (Lift off door) FL-500P-SLP- over With 1/4" eveled luminum arpet Flange (Lift off door) FL-500P-SSQ- over With 1/4" Square luminum Flange (Lift off door) FL-500P-PLP-GRY- over With 1/4" Painted arpet Flange - Gray (lift off door, solid cable access ) FL-500P-PLP-LY- over With 1/4" Painted arpet Flange - lay (lift off door, solid cable access ) FL-500P-PLP-LK- over with 1/4" Painted arpet Flange - lack (lift off door, solid cable access ) Flat overs FL-500P-LK- over (No Flange) With Hinged Door in lack Sandtex FL-500P-OK- over (No Flange) With Hinged Door in Lt. Oak Sandtex FL-500P-SS- Stainless Steel over (No Flange) with Hinged Door ack oxes - Includes Steel onstruction over FL-500P-2.25- FL-500P ack ox - 2.25" Deep (Different Internal rackets) FL-500P-3- FL-500P ack ox - 3" Deep (Different Internal rackets) FL-500P-4- FL-500P ack ox - 4" Deep (UL) FL-500P-6- FL-500P ack ox - 6" Deep (UL) FL-500P-8- FL-500P ack ox - 8" Deep (UL) FL-500P-10- FL-500P ack ox - 10" Deep (UL) Pour Pan ccessory for Grade Installations FL-GRD2 2" Grade Mounting Kit FL-GRD4 4" Grade Mounting Kit Optional ackbox rackets FL-500P-2.25-Decora 2 Decora openings (No divider) Replaces lank Plate (2.25" ack box only) FL-500P-4.3G 3 Single Gang openings (No divider) Replaces 4G Plate (4 ack box only) FL-500P-6-3G 3 Single Gang openings (No divider) Replaces 4G Plate (6 ack box only) POUR PN ESSORY The FSR Pour Pan is the answer to floor box installations that are on grade. If your application is a poured concrete floor, but the box may rest on soil, rock, gravel, etc., you must first install the Pour Pan. The Pour Pan is set into the grade below the floor box and allows concrete to flow around and under the box to prevent the floor box from contacting the grade. The unit comes with extended length leveling feet, and the unique pan wings prevent the pan from shifting during the pour. Specifications are subject to change without notice. MDE IN THE US 244 ergen oulevard, Woodland Park, NJ 07424 Phone: 973.785.4347 Fax: 973.785.4207 Web: www.fsrinc.com E-mail: sales@fsrinc.com LIT1047F