Evaluation of Digital Refractometers for Field Determination of FSII Concentration in JP-5 Fuel

Similar documents
Evaluation of SpectroVisc Q3000 for Viscosity Determination

Navy Coalescence Test on Petroleum F-76 Fuel with Infineum R655 Lubricity Improver at 300 ppm

Navy Coalescence Test on Camelina HRJ5 Fuel

Joint Oil Analysis Program Spectrometer Standards VHG Labs Inc. Qualification Report For D19-0, D3-100 and D12-XXX Series Standards

Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report For D19-0, D3-100, and D12-XXX Series Standards

Impact of 200 ppm HiTEC 4898C Lubricity Improver Additive (LIA) on F-76 Fuel Coalescence

Robot Drive Motor Characterization Test Plan

Fuel System Icing Inhibitor Concentration Reduction Study

TARDEC Technology Integration

Cadmium Repair Alternatives on High-Strength Steel January 25, 2006 Hilton San Diego Resort 1775 East Mission Bay Drive San Diego, CA 92109

TARDEC --- TECHNICAL REPORT ---

Feeding the Fleet. GreenGov Washington D.C. October 31, 2011

AFRL-RX-TY-TM

UNCLASSIFIED: Dist A. Approved for public release. GVPM Track & Suspension Overview Mr. Jason Alef & Mr. Geoff Bossio 11 Aug 2011

Helicopter Dynamic Components Project. Presented at: HCAT Meeting January 2006

LESSONS LEARNED WHILE MEASURING FUEL SYSTEM DIFFERENTIAL PRESSURE MARK HEATON AIR FORCE FLIGHT TEST CENTER EDWARDS AFB, CA 10 MAY 2011

GM-TARDEC Autonomous Safety Collaboration Meeting

REMOTE MINE AREA CLEARANCE EQUIPMENT (MACE) C-130 LOAD CELL TEST DATA

Evaluation of Single Common Powertrain Lubricant (SCPL) Candidates for Fuel Consumption Benefits in Military Equipment

FINAL REPORT FOR THE C-130 RAMP TEST #3 OF A HYDREMA MINE CLEARING VEHICLE

TARDEC Robotics. Dr. Greg Hudas UNCLASSIFIED: Dist A. Approved for public release

Vehicle Systems Engineering and Integration Activities - Phase 3

UNCLASSIFIED: Distribution A. Approved for Public Release TACOM Case # 21906, 26 May Vehicle Electronics and Architecture

UNCLASSIFIED: Dist A. Approved for public release. GVPM Non-primary Power Systems Overview Kevin Centeck and Darin Kowalski 10 Aug 2011

EXPLORATORY DISCUSSIONS - PRE DECISIONAL

Does V50 Depend on Armor Mass?

Vehicle Systems Engineering and Integration Activities - Phase 4

Alternative Fuels: FT SPK and HRJ for Military Use

UNCLASSIFIED: Dist A. Approved for public release. GVPM Energy Storage Overview Mr. David Skalny & Dr. Laurence Toomey 10 August 2011

Servicing Hawker Vehicle Batteries with Standard Battery Charging and Test Equipment

US Army Non - Human Factor Helicopter Mishap Findings and Recommendations. Major Robert Kent, USAF, MC, SFS

UNCLASSIFIED: DIST A. APPROVED FOR PUBLIC RELEASE. ARMY GREATEST INVENTIONS CY 2009 PROGRAM MRAP Overhead Wire Mitigation (OWM) Kit

Automatic Air Collision Avoidance System. Auto-ACAS. Mark A. Skoog Dryden Flight Research Center - NASA. AutoACAS. Dryden Flight Research Center

US ARMY POWER OVERVIEW

EVALUATING VOLTAGE REGULATION COMPLIANCE OF MIL-PRF-GCS600A(ARMY) FOR VEHICLE ON-BOARD GENERATORS AND ASSESSING OVERALL VEHICLE BUS COMPLIANCE

An Advanced Fuel Filter

Open & Evolutive UAV Architecture

Presented by Mr. Greg Kilchenstein OSD, Maintenance. 29August 2012

2011 NDIA GROUND VEHICLE SYSTEMS ENGINEERING AND TECHNOLOGY SYMPOSIUM POWER AND MOBILITY (P&M) MINI-SYMPOSIUM AUGUST 9-11 DEARBORN, MICHIGAN

REPORT DOCUMENTATION PAGE

HIGH REPETITION RATE CHARGING A MARX TYPE GENERATOR *

Tank Automotive Research, Development and Engineering Command (TARDEC) Overview

U.S. Army/CERDEC's Portable Fuel Cell Evaluation and Field Testing 2011 Fuel Cell Seminar & Expo Orlando, FL 31 Oct 2011

INLINE MONITORING OF FREE WATER AND PARTICULATE CONTAMINATION OF JET A FUEL

High efficiency variable speed versatile power air conditioning system for military vehicles

Monolithically Integrated Micro Flapping Vehicles

Transparent Armor Cost Benefit Study

Portable Fluid Analyzer

Energy Storage Requirements & Challenges For Ground Vehicles

Transparent Armor Cost Benefit Study

INTELLIGENT ENERGY MANAGEMENT IN A TWO POWER-BUS VEHICLE SYSTEM. DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.

U.S. Army s Ground Vehicle Energy Storage R&D Programs & Goals

SIO Shipyard Representative Bi-Weekly Progress Report

Dual Use Ground Vehicle Condition-Based Maintenance Project B

Energy Storage Commonality Military vs. Commercial Trucks

DESULFURIZATION OF LOGISTIC FUELS FOR FUEL CELL APUs

Up-Coming Diesel Fuel and Exhaust Emissions Regulations For Mobile Sources. Parminder Khabra RDECOM-TARDEC TACOM LCMC March 22, 2006 JSEM

FTTS Utility Vehicle UV2 Concept Review FTTS UV2 Support Variant

DSCC Annual Tire Conference CATL UPDATE. March 24, 2011 UNCLASSIFIED: Dist A. Approved for public release

TARDEC OVERVIEW. Tank Automotive Research, Development and Engineering Center. APTAC Spring Conference Detroit 27 March, 2007

Additional Transit Bus Life Cycle Cost Scenarios Based on Current and Future Fuel Prices

Power Distribution System for a Small Unmanned Rotorcraft

F100 ENGINE NACELLE FIRE FIGHTING TEST MOCKUP DRAWINGS

TARDEC Hybrid Electric Program Last Decade

Additives to Increase Fuel Heat Sink Capacity

Joint Light Tactical Vehicle Power Requirements

Hydro-Piezoelectricity: A Renewable Energy Source For Autonomous Underwater Vehicles

REPORT DOCUMENTATION PAGE

Robust Fault Diagnosis in Electric Drives Using Machine Learning

TRANSIENT MAGNETIC FLUX DENSITY MEASUREMENT RESULTS ON A FUSELAGE-LIKE TEST SETUP AND INVESTIGATION OF THE EFFECTS OF APERTURES

BALANCE OF PERFORMANCE PARAMETERS FOR SURVIVABILITY AND MOBILITY IN THE DEMONSTRATOR FOR NOVEL DESIGN (DFND) VEHICLE CONCEPTS

Predator B: The Multi-Role UAV

Development of Man Portable Auxiliary Power Unit using Advanced Large Format Lithium-Ion Cells

Quarterly Progress Report

Application of Airbag Technology for Vehicle Protection

Multilevel Vehicle Design: Fuel Economy, Mobility and Safety Considerations, Part B

NoFoam Unit Installation, Evaluation and Operations Manual

Power Technology Branch Army Power Division US Army RDECOM CERDEC C2D Fort Belvoir, Virginia

Program Overview. Chris Mocnik Robotic Vehicle Control Architecture for FCS ATO Manager U.S. Army RDECOM TARDEC

Quantification of Corrosion Inhibitor/Lubricity Improver In Military Fuels using Infrared Spectroscopy

Fuel Efficient ground vehicle Demonstrator (FED) Vision

Blast Pendulum Testing of Milliken Tegris Panels

REPORT DOCUMENTATION PAGE

Membrane Wing Aerodynamics for µav Applications

Predator Program Office

Center for Ground Vehicle Development and Integration

Endurance Testing of Redesigned Tab Spring for MI-RAMS System

Methylene Chloride Alternative HAP-Free Chemical Paint Strippers at Anniston Army Depot

NDCEE National Defense Center for Energy and Environment

IMPACT OF FIRE RESISTANT FUEL BLENDS ON FORMATION OF OBSCURING FOG

FINAL REPORT. 29 May 1997

Report No. D November 24, Live Fire Testing of Light Tactical Wheeled Vehicles was Effective for the Portions Completed

EFFECTIVENESS OF LOW TEMPERATURE ADDITIVES FOR BIODIESEL BLENDS

DEVELOPMENT OF COMPACT VARIABLE- VOLTAGE, BI-DIRECTIONAL 100KW DC-DC CONVERTER

REPORT DOCUMENTATION PAGE

IMPACT OF FRICTION REDUCTION TECHNOLOGIES ON FUEL ECONOMY FOR GROUND VEHICLES G. R. Fenske, R. A. Erck, O. O. Ajayi, A. Masoner, and A. S.

Navy Field Evaluation of Particle Counter Technology for Aviation Fuel Contamination Detection

Report Documentation Page

MILITARY SPECIFICATION LUBRICATING OIL, VACUUM PUMP, MECHANICAL

U.S. Army s Ground Vehicle Energy Storage R&D Programs & Goals

Transcription:

Evaluation of Digital Refractometers for Field Determination of FSII Concentration in JP-5 Fuel NAVAIRSYSCOM REPORT 441/13-011 Prepared By: JOHN KRIZOVENSKY Chemist AIR 4.4.5 NAVAIR Public Release 2013-867 Distribution Statement A - Approved for public release; distribution is unlimited

Page ii Report prepared and released by: Naval Air Systems Command Naval Fuels & Lubricants CFT 22229 Elmer Road Patuxent River MD 20670-1534 Reviewed and Approved by: JACK BUFFIN ISE Team Lead AIR-4.4.5 RICHARD A. KAMIN Fuels Team Lead AIR-4.4.5 Released by: DOUGLAS F. MEARNS Fuels & Lubricants Systems Engineer AIR-4.4.1

Page iii TABLE OF CONTENTS Page LIST OF TABLES... iv LIST OF FIGURES... iv EXECUTIVE SUMMARY... v LIST OF ACRONYMS/ABBREVIATIONS... vi 1.0 BACKGROUND... 1 2.0 OBJECTIVE... 1 3.0 APPROACH... 2 4.0 DISCUSSION... 2 5.0 CONCLUSIONS... 3 6.0 RECOMMENDATIONS... 4 7.0 REFERENCES... 4

Page iv LIST OF TABLES Table Title Page Table 1 Dilution Quantities Required to Produce Desired Concentrations.... 2 Table A-1 Refractometer Test Results... A-1 LIST OF FIGURES Figure Title Page Figure 1 Averaged Refractometer Test Results... 3

Page v EXECUTIVE SUMMARY Specification MIL-DTL-5624 requires the addition of Diethylene Glycol Monomethyl Ether (DiEGME) as a fuel system icing inhibitor at a concentration of 0.10 vol% to 0.15 vol% at the point of additive addition. During transport of JP-5 fuel from the point of additive injection to the point of use, additive loss is experienced to some degree resulting in additive concentrations frequently below 0.1 vol%. Navy field determination of the additive concentration is currently conducted using the American Society for Testing and Materials, ASTM D5006 referenced HB/B2 Analog refractometer. The HB/B2 refractometer has been in service for over 30 years and is a very precise instrument for DiEGME concentrations above 0.03 vol%. However, HB/B2 analog refractometer scale reading at the low DiEGME concentrations requires interpolation and is subjective. The ASTM D5006 method recently included digital refractometer instruments for DiEGME concentration determination. More precise measurements of DiEGME at low concentrations could be obtained by Navy field operators with the use of the digital refractometers. NAVAIR successfully completed the evaluation of the digital refractometers and determined the ASTM Method D5006 referenced Gammon HB/2D Digital and the MISCO PA202 series digital refractometers are acceptable for Navy field determination of DiEGME fuel system icing inhibitor additive levels in Specification MIL-DTL-5624, JP-5 fuel.

Page vi LIST OF ACRONYMS/ABBREVIATIONS American Society for Testing and Materials... ASTM DiEthylene Glycol Monomethyl Ether... DiEGME Fuel System Icing Inhibitor... FSII

Page 1 Evaluation of Digital Refractometers for Field Determination of FSII Concentration in JP-5 Fuel 1.0 BACKGROUND Fuel System Icing Inhibitor 1 (FSII) has been a required aviation fuel additive since 1971. FSII became a necessary fuel additive after several reports of ice formation causing fuel system malfunctions and downed aircraft. FSII is able to prevent the formation of ice by preferentially migrating to dissolved water and free water where it acts as antifreeze for the water. Since the 1980s Di-Ethylene Glycol Monomethyl Ether 2 (DiEGME) has served as the Navy s anti-icing additive. The Navy has established the minimum effective concentration of DiEGME at 0.03% by volume 3. DiEGME is recommended for use in aircraft because of its secondary benefit of increased biostatic protection. Due to DiEGME s solubility in water, DiEGME is often times lost through exposure to tanks that have not been sumped adequately or through drastic temperature changes which cause water dissolved in the fuel to come out of solution and settle at the bottom of the tank as free water. To offset these losses the Navy requires a larger DiEGME concentration in procured fuels. Originally, the Navy required a concentration of 0.15%-0.20% by volume DiEGME in all procured fuels. But due to lower than anticipated DiEGME losses during fuel transport, the current injection range has been lowered to 0.10%-0.15% DiEGME. Research has been done to assess the feasibility of lowering the minimum required concentration of DiEGME even further. But before any real benefits can be drawn from reducing the allowable limits of DiEGME, a handheld refractometer that can accurately and precisely measure low levels of DiEGME must be identified. Current handheld analog refractometers are too subjective at lower concentration levels of DiEGME ( 0.03%) making it virtually impossible to definitively measure low concentrations of DiEGME in the field. An accurate digital refractometer would remove the subjectiveness associated with the current test equipment by providing a clearly displayed DiEGME concentration while also simplifying operation, and potentially reducing testing costs. 2.0 OBJECTIVE The purpose of this study is to validate the ruggedness and accuracy of the latest models of the MISCO and Gammon digital refractometers compared to the current Navy approved B2 analog refractometer and determine the acceptability of these instruments for Navy field use. Unlike previous studies, this effort places emphasis on lower detection levels ( 0.05 vol% DiEGME).

Page 2 3.0 APPROACH A stock solution of 0.2 vol% DiEGME in JP-5 fuel was prepared. Aliquots of the stock solution were used to prepare the other additive concentrations. The sample dilution schedule is shown in Table 1. The DiEGME concentration of each of the prepared samples was verified in accordance with the ASTM Method D5006 4. Table 1: Dilution Quantities Required to Produce Desired Concentrations DiEGME Concentration, Vol% Volume of 0.2% Solution Used Volume of DiEGME Free Fuel Required 0 0 1000 0.0025 15 985 0.005 25 975 0.01 50 950 0.03 150 850 0.05 250 750 0.1 500 500 0.15 750 250 0.2 2600 0 4.0 DISCUSSION 4.1 General/Visual Assessment. Both the Gammon HB/2D digital refractometer and the MISCO PA202 digital refractometer were small, light weight, and sufficiently rugged for Navy field use. The power source for both instruments is standard AA Alkaline batteries. Battery change was not required for either unit during the evaluation which is a good indication of long battery life. The instruments operating instructions provided were complete and easy to follow. Both instruments were very simple in design and easy to operate. Values displayed in the digital displays were easy to read. The cleaning procedures are simple and require no detergents or chemicals. 4.2 Determination of DiEGME in JP-5 Fuel. The ASTM D5006 procedure was followed for determining the DiEGME concentration in the JP-5 test fuels. The test results are shown graphically in Figure 1. The raw data is contained in Appendix A, Table A-1. Test results were obtained in triplicate. The results obtained for the Gammon HB/2D digital refractometer and the MISCO PA202 digital refractometer were nearly identical and demonstrated exceptional accuracy and precision. Due to the limitations of the HB/B2 Analog refractometer, results below 0.03 vol% concentrations were displayed as 0.0 vol%. However, both digital refractometers were able to accurately determine the DiEGME concentration to about 0.003 vol% in JP-5 fuel. All test results obtained were within the established ASTM D5006 precision requirements. The precision data is contained in Appendix B.

Page 3 Measured Vol % DiEGME in JP-5 0.220 0.200 0.180 0.160 0.140 0.120 0.100 0.080 0.060 0.040 0.020 0.000 0.000 0.003 0.005 0.010 0.030 0.050 0.100 0.150 0.200 Vol % DiEGME in JP-5 Figure 1: Refractometer Test Results Gammon MISCO Analog Standard 4.3 MISCO PA202X Similarity. Although the MISCO PA202X model was not included in this evaluation, contact with MISCO verified the PA202 and PA202X are comparable. The PA202X has the additional feature of a built in calibrated DiEGME scale. All other performance parameters are the same. Therefore, for qualification purposes, model PA202X shall be included. 5.0 CONCLUSIONS 1. The precision and accuracy of the Gammon HB/2D Digital Refractometer and the MISCO PA202/PA202X digital refractometers are equivalent to the B2 Analog refractometer. 2. The Gammon HB/2D digital refractometer and the MISCO PA202/PA202X digital refractometers are sufficiently rugged for Navy field use. 3. The Gammon HB/2D digital refractometer and the MISCO PA202/PA202X digital refractometers are acceptable instruments for Navy field determination of DiEGME additive concentrations in JP-5 fuel.

Page 4 6.0 RECOMMENDATIONS Revise the NAVAIR 00-80T-109 NATOPS Aircraft Refueling Manual and appropriate technical manuals and instructions to include the Gammon HB/2D digital refractometer and the MISCO PA202/PA202X digital refractometers for Navy field determination of DiEGME additive concentrations in JP-5 fuel. 7.0 REFERENCES 1. MIL-DTL-27686 Inhibitor, Icing, Fuel System (superseded by MIL-DTL-85470) 2. MIL-DTL-85470 Inhibitor, Icing, Fuel System, High Flash NATO Cold Number S-1745 3. NAVAIR 00-80T-109 Aircraft Refueling Manual 4. ASTM D5006 - Standard Test Method for Measurement of Fuel System Icing Inhibitors (Ether Type) in Aviation Fuels

Appendix A Page A-1 of 2 Table A-1: Refractometer Test Results DiEGME Concentration by ASTM D5006 (Test Temperature 70 F) DiEGME Level In Fuel Trial # vol% DiEGME Standard Gammon MISCO HB/B2 Analog 0.000 vol% Trial 1 0.002 0.002 0.00 Trial 2 0.002 0.002 0.00 Trial 3 0.002 0.002 0.00 Average 0.002 0.002 0.00 Std Dev 0.000 0.000 0.00 0.0025 vol% Trial 1 0.001 0.002 0.00 Trial 2 0.001 0.002 0.00 Trial 3 0.001 0.002 0.00 Average 0.001 0.002 0.00 Std Dev 0.000 0.000 0.00 0.005 vol% Trial 1 0.004 0.004 0.00 Trial 2 0.004 0.004 0.00 Trial 3 0.003 0.004 0.00 Average 0.004 0.004 0.00 Std Dev 0.001 0.000 0.00 0.010 vol% Trial 1 0.008 0.009 0.00 Trial 2 0.011 0.009 0.00 Trial 3 0.008 0.009 0.00 Average 0.009 0.009 0.00 Std Dev 0.002 0.000 0.00 0.030 vol% Trial 1 0.029 0.032 0.04 Trial 2 0.030 0.033 0.04 Trial 3 0.030 0.033 0.04 Average 0.030 0.033 0.04 Std Dev 0.001 0.001 0.00 0.050 vol% Trial 1 0.055 0.055 0.06 Trial 2 0.055 0.055 0.06 Trial 3 0.056 0.055 0.06 Average 0.055 0.055 0.06 Std Dev 0.001 0.000 0.00 0.100 vol% Trial 1 0.110 0.110 0.11 Trial 2 0.111 0.110 0.11 Trial 3 0.112 0.111 0.11 Average 0.111 0.110 0.11 Std Dev 0.001 0.000 0.00 0.150 vol% Trial 1 0.151 0.150 0.15 Trial 2 0.150 0.151 0.15 Trial 3 0.150 0.150 0.15 Average 0.150 0.150 0.15 Std Dev 0.001 0.001 0.00 0.200 vol% Trial 1 0.199 0.200 0.20 Trial 2 0.200 0.199 0.19 Trial 3 0.199 0.200 0.20 Average 0.199 0.200 0.20 Std Dev 0.001 0.001 0.01

Appendix A Page A-2 of 2 Precision The precision of this test method as determined by statistical examination of interlaboratory results according to RR:D02-10075 is as follows: 1. Repeatability HB refractometer: repeatability 0.009 volume % Brix scale refractometer: repeatability 0.005 volume % 2. Reproducibility HB refractometer: reproducibility 0.018 volume % Brix scale refractometer: reproducibility 0.021 volume %

REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing this collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 07-02-2013 Technical 4. TITLE AND SUBTITLE Evaluation of Digital Refractometers for Field Determination Of FSII Concentration in JP-5 Fuel 6. AUTHOR(S) Krizovensky; Author Buffin, Jack.; Editor Kamin, Richard ; Editor Mearns, Douglas ; Editor 3. DATES COVERED (From - To) 01-11-2011 to 01-23-2012 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER Naval Fuels & Lubricants NFLCFT Report 441/13-011 Cross Functional Team 22229 Elmer Road Patuxent River, MD 20670 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR S ACRONYM(S) Naval Air Systems Command NPRE Program 22347 Cedar Point Road 11. SPONSOR/MONITOR S REPORT Patuxent River MD 20670 NUMBER(S) 12. DISTRIBUTION / AVAILABILITY STATEMENT A Approved for public release; distribution is unlimited. 13. SUPPLEMENTARY NOTES 14. ABSTRACT Specification MIL-DTL-5624 requires the addition of Diethylene Glycol Monomethyl Ether (DiEGME) as a fuel system icing inhibitor at a concentration of 0.10 vol% to 0.15 vol% at the point of additive addition. During transport of JP-5 fuel from the point of additive injection to the point of use, additive loss is experienced to some degree resulting in additive concentrations frequently below 0.1 vol%. Navy field determination of the additive concentration is currently conducted using the American Society for Testing and Materials, ASTM D5006 referenced HB/B2 Analog refractometer. The HB/B2 refractometer has been in service for over 30 years and is a very precise instrument for DiEGME concentrations above 0.03 vol%. However, HB/B2 analog refractometer scale reading at the low DiEGME concentrations requires interpolation and is subjective. The ASTM D5006 method recently included digital refractometer instruments for DiEGME concentration determination. More precise measurements of DiEGME at low concentrations could be obtained by Navy field operators with the use of the digital refractometers. NAVAIR successfully completed the evaluation of the digital refractometers and determined the ASTM Method D5006 referenced Gammon HB/2D Digital and the MISCO PA202 series digital refractometers are acceptable for Navy field determination of DiEGME fuel system icing inhibitor additive levels in Specification MIL-DTL-5624, JP-5 fuel. 15. SUBJECT TERMS Fuel System Icing Inhibitor, FSII, HB/B2 Refractometer, Digital Refractometer 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT a. REPORT UNCLASSIFIED b. ABSTRACT UNCLASSIFIED c. THIS PAGE UNCLASSIFIED Unclassified Unlimited 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON Douglas F. Mearns 13 19b. TELEPHONE NUMBER (include area code) 301-757-3421 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18