USER MANUAL. Line Interactive UPS. Uninterruptible Power System

Similar documents
Line Interactive UPS 1000/1400/2000VA Uninterruptible Power System

BRAVER UPS. (Uninterruptible Power System) User s Manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

USER MANUAL. Uninterruptible power supply MODEL: 53965,

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

1. INTRODUCTION. Features:

Uninterruptible Power System

General Precautions. Personnel Precautions

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Uninterruptible Power Supply

Uninterruptible Power System

OPERATING INSTRUCTION UPS PROTECT A. PROTECT A PROTECT A. 1400

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Uninterruptible Power System

Limousin II User Manual

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

CP900EPFCLCD User s Manual K

PR1000ELCD / PR1500ELCD User s Manual

MM-AVR UPS Series User s Manual

USER MANUAL MPS 1-5KW SERIES

Uninterruptible Power System

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Eclipse Plus VA UPS and Surge Suppressor User s Manual

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

UTILITY INPUT MAINS OUTLET

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

USER MANUAL ONLINE UPS

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

User Manual V1.0 MaxiFlex 3000

Informer Compact Series

OPERATIONAL MANUAL .TYPE - ONLINE UNINTTERRUPTIBLE POWER SUPPLY

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

1. Important Safety Warning

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

SCC-MPPT Solar Charge Controller

Installation and Operation Manual Back-UPS BX1100CI-CN

Liebert GXT MT+ User Manual VA Installer/User Guide

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

SCC-MPPT Solar Charge Controller

Pulsar Evolution 2200/3000/3000 XL

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

User s Manual. Automatic Switch-Mode Battery Charger

USER MANUAL DN / DN

Sola/Hevi-Duty S3K Series Mini-Tower UPS

USER MANUAL. PowerMust 1080 LCD (1KVA), Online, IEC PowerMust 2016 LCD (2KVA), Online, IEC PowerMust 3024 LCD (3KVA), Online, IEC

CX-SERIES ADVANCED BATTERY CHARGER

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

POWERWARE User s Guide VA.

Solar Charge Controller

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

Powerware Vdc Extended Battery Cabinet User s Guide.

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

IS1100LT/ IS2200LT/ IS3000LT/ IS5000LT IS2000LR/ IS2700LR/ IS4000LR/ IS5000LR

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

U P S. Uninterruptible Power System Unterbrechungsfreie Stromversorgung

User Manual Rittal PMC UPS 6kVA

User M anual. Rack/Tower Online UPS 1K/1.5K/2K/3K

GSL Electronics Modified Sine Wave Power Inverters

SCC-MPPT Solar Charge Controller

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

BS20 BATTERY CHARGER For lead-acid batteries

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Installation and Operation Back-UPS BX550CI-CN

1. IMPORTANT SAFETY INSTRUCTIONS

FALCON ELECTRIC, INC.

User Manual. 3kW Hybrid PV Inverter HX-3000

OWNER S MANUAL POWER INVERTER

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Transcription:

USER MANUAL Line Interactive UPS Uninterruptible Power System

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models Line Interactive 400, 600, and 800 that should be followed during installation and maintenance of the UPS and batteries.

Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs. Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery. Connection to any other type of receptacle other than a two-pole, three-wire grounding receptacle may result in s shock hazard as well as violate local electrical codes. In the event of an emergency, turn the power switch to the off position and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity. Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries : 1) Remove watches, rings, or other metal objects from the hand. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on the top of batteries. 5) Disconnect charging source prior to connecting or disconnecting batteries terminal.

Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same type and number of the sealed lead-acid batteries. The maximum ambient temperature rating is 40. This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen. During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA. Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary. The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible. Wichtige Sicherheitshinweise Bitte lesen Sie diese Hinweis sorgfaltig durch. Vor jedem rcinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie Keine Flüssig-oder Aerosolreiniger. Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung. Das Gerät ist vor Feuchtigkeit zu schützen. Ö ffncn Sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisicrtem Servicepersonal geöffnct Wcrdcn. Bei der Installation is darauf zu achten, das der Gesamtableitstrom der USV und der and der USV angeschlossenen Verbraucher den. Maximalwert von 3.5mA nicht überschreiten. VORSICHT: Explosionsgetahr bei unsachgemäßen Austausch der Batterie. Ersatz nur durch denselben order einem vom Hersteller empfoblenem ähnlichen Typ. Entsorgung gebrauchter Batterien nach Angaben des Herstellers.

1. Introduction This UPS is specially designed for Personal Computer with multi-functions. Its light weight, compact design perfect fits to the limited working environment. The line of UPS is equipped with boost and buck AVR to stabilize input voltage range. It is also built-in with DC start function. This function enables the UPS to be started up without AC power supplied. Although it s a small UPS, it s equipped with Smart RS-232 Communication Port to offer users more benefits. The download software helps users monitor UPS inside status. The main features of the UPS are listed below: Microprocessor control guarantees high reliability. Equipped with Boost and Buck AVR. Built-in RS-232 Communication Port. Free Software Download from the Internet. (Please check Free Software Download in Installation & Operation for detail information). Green Power Function for energy saving. DC Start Function. Auto restart while AC recovery. Compact size, Light Weight. Provides Modem/Phoneline surge protection. USB Option.. 2. Installation and operation 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase.

2. Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours with no load (no electrical devices such as computers, monitors, etc.) connected. 3. Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. On the other hand, place the UPS away from the monitor at least 20cm to avoid interference. 20cm

4. Connection Plug the UPS into a 2-pole, 3-wire grounded receptacle. Then connect one computer-related device into each of the power receptacles supplied on the back of the UPS. 5. Turn On/Off To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again. 6. DC Start All this Series are equipped with DC Start. To start the UPS when AC utility power is not available, simply press the power switch. 7. Green Power Function This UPS is equipped with Green Power Function. For saving power and protecting battery, the method of deep discharging protection is adopted on inverter mode. 8. Free Download Software WinPower Go to the website: http://www.ups-software-download.com/winpower.htm Choose the operation system you need and follow the instruction described on the website to download the software. When downloading all required files from the internet, enter the serial No: 511C1-01220-0100-478DF2A to install the software. Note: The Power Switch must be kept in the ON position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure.

3. System Description Front panel: 1. Power Switch 2. LED Indicators AC Mode: Green lighting Battery Mode: Green flashing Back Panel 1. Output receptacles 2. AC input with AC fuse 3. Modem/Phoneline Surge Protection 4. USB Communication Port

4. Trouble Shooting Symptom Possible Cause Remedy No LED display 1. Missing battery. 1. Charge battery up to 8 on the front hours. panel. 2. Battery defect. 2. Replace with the same type of battery. 3. Power switch is not pressed. 3. Press a power switch again. Alarm buzzer beeps continuously when AC supply is normal. Overload of the UPS. Verify that the load matches the UPS capability specified in the specs. When power failure, back-up 1. Overload of the UPS. 1. Remove some noncritical load. time is shorten. 2. Battery voltage is too low. 2. Charge battery 8 hours or more. Mains normal but LED is flashing. 3. Battery defect due to high temperature operation environment, or improper operation to battery. 3. Replace with the same type of battery. 1. Fuse is blown. 1. Replace the same type of fuse. 2. Power cord is loose. 2. Reconnect the power cord properly. If any abnormal situations occur that are not listed above, please call service people immediately.

5. Specification 6. MODEL 400 600 800 CAPACITY VA/W 400VA/240W 600VA/360W 800VA/480W Voltage 110/120VAC or 220/230/240VAC INPUT Voltage Range 81-140VAC or 162-290VAC Frequency 45-65 Hz (Auto Sensing) Voltage 110/120/220/230/240VAC Voltage Regulation (Batt. Mode) +/-10% OUTPUT Frequency 50Hz or 60Hz Frequency Regulation (Batt. Mode) +/-1 Hz Output Waveform Modified Sinewave Battery Type 6V4Ah x 2 or 12V4.5Ah x 1 12V7Ah x 1 12V9Ah x 1 Backup Time (at a PC BATTERY load with 15 monitor) 12 minutes 23 minutes 34 minutes TRANSFER TIME INDICATOR AUDIBLE ALARM Recharge Time Typical AC Mode Backup Mode Backup Mode Low Battery Overload Battery Replacement Fault 8 hours to 90% after complete discharge 2-6 ms Green lighting Green flashing Sounding every 10 seconds Sounding every second Sounding every 0.5 second Sounding every 2 seconds Continuously sounding PROTECTION Full Protection Discharge, overcharge, and overload protection Dimension (mm), PHYSICAL DXWXH 330X100X140 WEIGHT Net Weight 5kgs 6kgs 6.5kgs Operating Environment ENVIRONMENT 0-40 C, 0-90 % relative humidity (non-condensing) Noise Level Less than 40dB INTERFACE USB Port Windows 98/2000/ME/XP