KEANE MONROE a member of the record group

Similar documents
9540 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

LCN 9540 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

LCN 9740 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

SENIOR SWING UNIQUE FEATURES

9550 SERIES FEATURES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS

6100 Series Swing Door Operator Installation Instructions

*PULL SIDE mount shown

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

7100SZ Series SafeZone Installation and Instruction Manual

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

LCN 2810 SERIES OPERATOR MOUNTS SINGLE DOOR, OVERHEAD CONCEALED CENTER PIVOT ARM OFFSET PIVOT/BUTT HINGE

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

*CENTER PIVOT arm shown

2860 SERIES FEATURES OPERATOR MOUNTS INDEPENDENT PAIR, OVERHEAD CONCEALED *CENTER PIVOT OFFSET PIVOT/BUTT HINGE

9560 Series Senior Swing. Features. Special Templates. Cover Fasteners Mounting. Certifications

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

Series 2003T. Belt Drive Telescoping Slide Door INSTALLATION INSTRUCTIONS. To be used with H210 C2150 Ver.10 Control Setup Instructions

9550 Series Senior Swing. Features. Special Templates. Certifications. Fasteners Mounting

*CENTER PIVOT arm shown

Power drill Center punch Wire stripper

INSTALLATION INSTRUCTIONS

9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

LCN AUTOMATIC OPERATORS

Electro-Mechanical Swing Operator. Table of Contents

2850 Series Senior Swing. Features. Special Templates. Certifications. Fasteners Mounting

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

9530 Series Senior Swing. Features. Special Templates. Fasteners Mounting. Certifications

Dor-O-Matic. Senior-Swing Universal Control Box. Instruction Manual Universal Control Box DOR-O-MATIC

LCN 9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

DETEX Low Energy Automatic Door Operator AO19-1 Single Door - Push

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

*ININST.1002* 1690 Touchbar. Index:

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

ASSA ABLOY Universal Door Closers

Series 4100 Surface Applied Swing Door Operator with C4190 Control

5600 Series Power Operator Installation and Instruction Manual

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Allegion LCN Benchmark AU9100 Series

TS93 EMF T/PT/TDE. Surface applied door closer

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

NON-SIZED SIZED HANDED

CONCEALED CLOSER SERIES

DC4000 Series LE Operator

Hunter Automatics HA-8. Installation Manual

LCN 4310ME SERIES FEATURES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled

LCN 9130 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PULL) OFFSET PIVOT/BUTT HINGE

LCN 4310ME SERIES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled. closer/holder designed to provide

Power Operators. Requirement. Approved Manufacturers. -All Operators To Be Electrically Powered -Operators To Be Aluminum (BHMA 689) Finish

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM

NON-SIZED SIZED HANDED

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8" I.D. Air Inlet Tubing Connected To Control Box

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

HIGH SECURITY CLOSERS SERIES

CONCEALED CLOSER SERIES

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E

HIGH SECURITY SERIES

Norton ABS-AMERICAN BUILDING SUPPLY, INC Series Multi-Sized Closers - Packed 6 per case

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

ED900. Low energy operator. Installation instructions: T/slide channel/pull arm mounting

Dor-O-Matic. Astro Swing Universal Control Box. Instruction Manual Universal Control Box

9550 SERIES FEATURES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS

ADA EZ Rev. H, 8/23/11

Gyro Tech Swing Door Conversion Unit (C.U.) Hardware Installation and Service Manual

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

TOYOTA RAV4/HV INTERIOR LIGHT KIT Preparation

These door closers should NOT be installed on the exposed side (weather side) of exterior doors.

MF 9690, 9790, Challenger 660, 670

*ININST.1039* 2390 Touchbar

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

9700/F9700 SERIES RIM EXIT DEVICE

TOYOTA HIGHLANDER RUNNING BOARD HIGHLANDER HV Preparation

PARTS & SERVICE MANUAL

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018)

5300 Series 5300 SERIES

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Series 78-B/FHA Hold Open

2904 Power Supply Installation Instructions I-EA00041

MOUNTING FINISH COVER CYLINDER **ARM FUNCTION REGULAR (DOUBLE) DESIGNER METAL NON-HANDED NON-SIZED

PULL SIDE MOUNTED PUSH SIDE MOUNTED DOUBLE LEVER ARM LEVER ARM P DOUBLE LEVER ARM SINGLE LEVER ARM 4110T 4210T*

Installation Instructions

*24828* 1 Installation. Left Hand Shown, Right Hand Opposite. Customer Service

4640 shown POWER OPERATOR HOLD-OPEN ACCESSIBILITY* NON-HANDED NON-SIZED

Section H4 GT350 OHC, Magnum 2, 3 & 4 Control, Single. Header Pivots Operator Control Board...13

D O O R C L O S E R S

Worldlawn Power Equipment, Inc. Industrial Park 2415 Ashland Ave. Beatrice, NE Toll Free Number:

Electrohydraulic Powered Systems

Installation Instructions

Model 2300DL Installation Guide

Standard Plastic Template P/N: (3-0) P/N: (4-0)

51 Series Door Closers. An ASSA ABLOY Group brand

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

T57 SERIES LOW ENERGY OPERATOR INTRODUCTION FEATURES BENEFITS PATENTS TABLE OF CONTENTS

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

MODEL 3002xTJ32 ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS

Transcription:

SERIES 3000 / 3100 MICROPROCESSOR CONTROL REGULAR ARM SLIDE ARM / SLIDE ARM W/PANIC BREAKAWAY

SERIES 3000 / 3100 Page 1. INDEX and OPERATOR HANDING The KM Series 3000/3100 operators have been carefully designed, built, and tested to provide years of service. The life of these operator packages is directly related to how carefully the installation is accomplished and how accurately the instructions are followed. Installation of these operator packages should be done by properly trained and knowledgeable installers with a knowledge of local code requirements and the requirements of ANSI A156.10 Standards for Power Operated Pedestrian Doors and ANSI A156.19 Standards for Low Energy and Power Assisted Pedestrian Doors. The authorized service/ installation dealer must perform all measurements for forces, speeds, and times to insure proper and safe operation. KM Systems is not responsible for improperly adjusted or maintained automatic doors or activation/ safety systems and assumes no responsibility for damages caused by automatic door systems that have not been properly installed, tested, and adjusted. INDEX HAND OF DOOR IDENTIFICATION 1 ELECTRICAL PREPARATION. 2,3 HEADER PREPARATION AND INSTALLATION. 4,5,6 OPERATOR INSTALLATION RH OUT & LH IN. 7 OPERATOR INSTALLATION- LH OUT & RH IN. 8 OPERATOR HANDING & TIMING 9 CONTROL IDENTIFICATION, INSTALLATION, & SETUP. 10,11 REGULAR ARM INSTALLATION-BUTT HINGE... 12 REGULAR ARM INSTALLATION-CNTR. PIVOT.. 13 SLIDE ARM INSTALLATION BUTT HINGE & CNTR. PIVOT.. 14 DOOR SPEED TABLES. 15 COVER INSTALLATION 16 SIGNAGE AND CODE CONFORMANCE... 17 ADJUSTMENT AND WIRING DIAGRAM 18,19 READ BEFORE INSTALLING. The sequence of installation and adjustment is in order, however some sections will not apply. Review this instruction manual and determine those sections that do apply. Be sure all doors swing freely and clear all objects before attaching arms. Special attention needs to be given to installations with parallel and slide arms when an adjacent wall is perpendicular to the door frame. HAND OF DOOR IDENTIFICATION LHR (RH OUT) REGULAR ARM RHR (LH OUT) REGULAR ARM LH SLIDE ARM RH SLIDE ARM LH SLIDE ARM W/PANIC RH SLIDE ARM W/PANIC

SERIES 3000 / 3100 Page 2. ELECTRICAL PREPARATION OWNER INFORMATION TO BE PROVIDED BY THE DISTRIBUTOR / INSTALLER After the installation, instruct the owner on the safe operation of the door. Location and proper use of the power switches. Location of the power breaker. Necessary warnings not covered in general instructions. Owners Manual and Daily Checklist. Phone number(s) for the local servicing dealers. What to do in the event a dangerous situation should occur, and how to shut the doors down and call for service. Electrical preparation Before preparing jambs, determine the method and requirements for the electrical wiring involved and whether mats or other type of activation is used. For mounting on/off switch proceed to Operator Installation section. CAUTION: Some local codes require on/off switches to be located no more than 6 6 above the floor. A suggested method of installation is to prepare a 1 1/2 dia. hole as shown. To install, place switch through top hole (1 1/2 dia.) while holding lead wires, lower switch to second hole (1/2 dia.) and fish out toggle end of switch. Install tabbed legend washer with mounting nut and secure with self tap screw.

SERIES 3000 / 3100 Page 3. ELECTRICAL PREPARATION Electrical Power Header Concealed Run flexible conduit or 3-wire cable down side jamb, through cutout. Trim sufficient length of wire and insert into 90 connector. Attach connector to bracket and secure with locknut. Trim wire to proper length when wiring unit. Secure wire to operator base or control. End Cap 90 Conduit Bracket (By others) 90 Conduit Connector Surface Mount Connect 90 elbow to bracket as shown, pull sufficient length of wire. Trim to proper length when wiring unit. Secure ground wire to base or control. Header Header End Cap

Header Installation Before preparing the frame for the header, determine if the equipment is the correct hand and arm type. To properly identify the hand of the door, refer to the Hand of Door Section on page 1. The header shown below is a left hand out (RHR) or (RH) right hand in. (shown with hidden door stop for RH IN) SERIES 3000 / 3100 Page 4. HEADER INSTALLATION Mounting the Header Be sure there is proper support in the wall to secure the header at the vertical jambs, and behind the header at intervals between the vertical jambs. Secure to top of door frame with the appropriate fasteners as indicated in Hole Instructions below. 4-3/4" (Ref. Only) * 1-1/2 1/4-20 x 1-1/4 Machine Screw or #14 x 1-1/4 Sheet Metal Screw Hole Instructions For metal frames with 1/8" material thickness, drill #21 hole and tap for 10-32 x 3/4" machine screws as required. For metal frames with less than 1/8" material thickness or wood frames, drill #29 pilot hole for #10 x 1-1/4" sheet metal screws as required. 1-1/2 3/8 * * Header Locating Dimensions Centerline of Pinion 8" on center (as req'd.) * 1/2" For Regular Arm only *1-1/4" for In-Swing Slide Arm 6" Bottom of Frame Pivot Jamb Warning : Do not permit the operator pinion to drop below the bottom of the door frame for inswing applications. Note: 1. All door frames for regular and parallel arm operation must be provided with door stops. 2. Door and frames for parallel operation with panic breakaway must be center pivoted or be capable of swinging in both directions with no stops. 3. For exterior installations, mount the on/off switch on the bottom of the header, not on the endcap.

SERIES 3000 / 3100 PAGE 5. HEADER ANCHORAGE Header Anchorage Aluminum Frame Header 1/4-20x1 1/4 Mach. Screw or #14x1 1/4 Sht. Mtl. screw Side Jamb #10x1 1/4 Sht. Mtl. or 10-32x3/4 Mach.screw Door Stop Door Hollow Metal Frame Header Spacer Plaster or Masonry Anchor #10x1 1/4 Sht. Mtl. 10-32x3/4 Mach.screw Door Stop Door Wood Frame Header #14x1 1/4 Sht. Mtl. screw #10x1 1/4 Flt. Hd. Sht. Mtl. screw Door Stop Door

SERIES 3000 / 3100 PAGE 6. HEADER PREPARATION, SINGLE AND DUAL Header Endcap Installation 1. Install header endcap brackets to header with 10-32 flat head screws. ( For dual units, center bracket is required. 2. Install endcap to each end bracket after removing perforated knockout where needed for conduit connection for electrical service. 3. Locate header on door frame as shown on page 4 and secure. Header endcap brackets (2 for single, 3 for dual) Endcap with perforated knockouts for conduit connection. Note: If the header being installed is a small dual, it may be necessary to omit the center support bracket in order to install the control.

SERIES 3000 / 3100 PAGE 7. OPERATOR INSTALLATION LHR & LH IN OPERATOR MOUNTING - REGULAR & SLIDE ARM READ PAGE 10 & 11 BEFORE CONNECTING CONTROL LHR (RH OUT) SHOWN & LH IN, RHR (LH OUT) & RH IN OPPOSITE. Install the operator in the header as shown below; align the four mounting holes in the header with the shock mount grommets on the operator. Use the 1/4-20 flat head screws provided to secure the operator through the header and shock mount grommets and into the pre-attached clamping plates inside the operator. READ PAGES 10 & 11 BEFORE PROCEEDING ANY FURTHER!! Control See Note 2. Shown in vertical position for representation only. See Note 1. Grommets Grommets Limit Switch Limit Switch Operator Clamping Plate Output Shaft Clamping Plate Output Shaft Note 1. For LH IN, the spring tube is towards the cover and the limit switch is opposite. Note 2. Before installing the control see Pages 10 & 11 for setup instructions. Shaft Timing: The operator output shaft is in the full panic position when received from the factory. See Pages 12 & 13 for proper setup of arm / operator timing. Limit Switch: Once the door arm is installed, make sure the limit switch is set to provide proper latch check position to obtain safe door operation. (For door open settings see Page 15.)

SERIES 3000 / 3100 PAGE 8. OPERATOR INSTALLATION RHR & RH IN OPERATOR MOUNTING - REGULAR & SLIDE ARM READ PAGE 10 & 11 BEFORE CONNECTING CONTROL LHR (RH OUT) SHOWN & LH IN, RHR (LH OUT) & RH IN OPPOSITE. Install the operator in the header as shown below; align the four mounting holes in the header with the shock mount grommets on the operator. Use the 1/4-20 flat head screws provided to secure the operator through the header and shock mount grommets and into the pre-attached clamping plates inside the operator. READ PAGES 10 & 11 BEFORE PROCEEDING ANY FURTHER!! Limit Switch Grommets See Note 1. Control See Note 2. (Shown in vertical position for representation only.) Clamping Plates Output Shaft Note 1. For RH IN, the spring tube is towards the cover and the limit switch is opposite. Note 2. Before installing the control see Pages 10 & 11 for setup instructions. Shaft Timing: The operator output shaft is in the full panic position when received from the factory. See Pages 12 & 13 for proper setup of arm / operator timing. Limit Switch: Once the door arm is installed, make sure the limit switch is set to provide proper latch check position to obtain safe door operation. (For door open settings see Page 15.)

SERIES 3000 / 3100 PAGE 9. OPERATOR HANDING AND TIMING Right Hand In Limit Switch Assy. Stop Block on Output Gear Cam Cam Spring Assy. Spring Assy. Left Hand Out (RHR) Limit Switch Assy. Limit Switch Assy Spring Assy. Spring Assy. Cam Stop Block on Output Gear Stop Block on Output Gear Limit Limit Switch Switch Assy. Assy Left Hand In Stop Block on Output Gear Stop Block on Output Gear Right Hand Out (LHR) Spring Assy. Spring Assy. Spring Spring Assy. Assy. Cam Cam Limit Limit Switch Switch Assy Assy. Cam Stop Block on Output Gear Stop Block on Output Gear Note: 1. The limit switch is labeled LC for latch check. 2. The stop block is located on the final stage gear and is shown in the door paniced position. 3. The door open and panic stop adjustment screws are shown, but the 90 door open position has to be calibrated as described on page 11.

SERIES 3000 / 3100 PAGE 10. CONTROL IDENTIFICATION AND SETUP The 3000 series control will be setup as either a full power (3000) control or a low energy (3100) control. To accomplish this the software is changed in the microprocessor. For ease of identification, the control will be marked with either an orange sticker or a green sticker located on the top of the close speed potentiometer bracket. The orange sticker is full power; the green sticker is low energy. FULL POWER CONTROL Orange sticker for full power Adjust to ANSI A156.10 The calibration jumper may not be in the jumpered position from the factory, see setup instructions for proper sequence of programming. The Obstruction Shut Down feature is recommended on full power applications. See adjustment diagram 8-30-0001 (pg 18) for location of adjustments. LOW ENERGY CONTROL Green sticker for low energy. Adjust to ANSI A156.19 The calibration jumper may not be in the jumpered position from the factory, see setup instructions for proper sequence of programming. The Obstruction Shut Down feature is recommended on low energy applications. See adjustment diagram 8-30-0002 (pg 18) for location of adjustments.

SERIES 3000 / 3100 PAGE 11. CONTROL INSTALLATION AND SETUP Control Installation and Setup DO NOT APPLY POWER TO THE CONTROL. Completely clean the header area to make sure there are not metal particles on the circuit board or under the control that could cause a short circuit. CAUTION: SHOCK HAZARD Use caution when making any adjustments or connections to the control. As with all electrical controls, there are live voltages present on the board or components when the power is applied. Single Locate the control near the operator with the adjustment knobs positioned towards the cover. Connect operator, on/off/hold open harness, signal input harness, panic harness (if applicable), and power harness (always connect last) as shown on diagram 8-30-0003 at the back of this manual. Dual Locate control near the RH operator as described above. Use operator extension harness provided for the other operator and make all applicable connections as above. Setup Note: Operators must be configured that when the door is at the 90 full open position, the stop block in the gearbox is to be against the stop bolt to achieve a good calibration.. Also, go to each operator harness plug, to the brown and yellow wire locations (encoder wires), and push in on them individually to make sure they are in and making contact. Suggested settings for Calibration: Turn all the adjustment settings to the 12 o clock position with the exception of Back Check speed; turn it all the way clockwise, and turn Time Delay to the 3 o clock position. To setup the control for programming, the calibration jumper (W12) must be in place (both pins) when power is applied. Once the door(s) is in motion, remove jumper and place it on one post for storage. The door(s) will go open slowly to the full open position (against the stop block in the gearbox) and drift back slightly, stop and then close. During this process, you will observe LED s alternately blinking. An operator plugged into the J1 connection on a single or dual control will have the red OBS LED and the yellow PTS LED blinking as the control receives information from the encoder/motor. In the case of a dual control, with the second operator plugged into the J5 connection, you should also observe the green SYS LED AND THE RED APU LED blinking as it also receives encoder information. One or both appropriate LED s not lighting (blinking) during calibrate indicates lack of encoder information from that operator. Once this sequence has occurred, the control is ready for normal operation. Recalibrate if the door is not allowed to get to the door open position (to the hard stop). Attention: When the power switch is turned on in the morning, the door must go completely to the door open position (against stop block in gear box) in order to run properly. Should the door meet an obstruction, turn the door off, remove obstruction, and reapply power. Once the operator has gone through the calibration process, adjust the door speeds and check positions according to the type of installation (full power or low energy). The control can provide several features for different types of applications; See page 9 for ANSI adjustment and the control diagram in the back of this manual for adjustments. Caution! When adjusting door open speed, obstruction sensitivity must be adjusted accordingly. (e.g. speeding the door up requires the Obstruction shutdown to be less sensitive). The four(4) position dip switch allows Push-to-start, Latch Assist, Ratchet, and Stack Pressure to be selected by putting the switch lever in the down position. Accessory 24vac power (connector J6) is controlled by fuse F3 and is limited to 1 amp total. Use UL listed cable type CL2, CL2P, CL2R, or CL2X or equal for accessory connection.

SERIES 3000 / 3100 PAGE 12. REGULAR ARM - BUTT HINGE INSTALLATION Note: Some installations will not have enough room to install the arm on the output shaft with the operator in the panic position. If this condition exists, allow the operator to go through a calibrate cycle and then put the control in hold open. Attach the arm to the operator and door and shut off the switch. Reinstall calibration jumper and let the control calibrate. Remember to remove the jumper and place on one post after the door is in motion. REGULAR ARM - BUTT-HINGE INSTALLATION! DOOR FRAME MUST HAVE DOOR STOP 1 5/16 2 1/4 8 3/4 for Butt or Swing Clear Hinges Hole Instructions Hinge Centerline For Metal Doors with 1/8 surface thickness Drill #7 hole and tap for 1/4-20 x 5/8 M.S. (2 holes). For Metal Doors with less than 1/8 surface thickness or Wood Doors, Drill 3/16 pilot hole for #14 x 1 1/4 SMS (2 HOLES). Note: All hole locations shown above are located from centerline of pivot or hinge. B* See correct chart below for Pivot and arm information 3000 & 3100 A C 90 Note: B dimension is from center line of pivot location to first door shoe screw. A dimension is the depth of reveal from face of frame to face of door. * 3100 Depth of Reveal A 2 2 1/2 3 3 1/2 4 4 1/2 5 5 1/2 6 Pivot to 1st Dr Shoe Screw B 8 3/4 8 3/4 8 3/4 8 3/4 8 3/4 8 3/4 8 3/4 8 3/4 8 3/4 Total Sec. Arm Length C 15 15 1/2 16 16 1/2 17 17 1/2 18 18 1/2 19 Secondary Rod Length -- 13 13 1/2 14 14 1/2 15 15 1/2 16 16 1/2 17 * 3000 Depth of Reveal A 2 2 1/2 3 3 1/2 4 4 1/2 5 5 1/2 6 Pivot to 1st Dr Shoe Screw B 10 3/4 10 3/4 10 3/4 10 3/4 10 3/4 10 3/4 10 3/4 10 3/4 10 3/4 Total Sec. Arm Length C 16 16 1/2 17 17 1/2 18 18 1/2 19 19 1/2 20 Secondary Rod Length -- 14 14 1/2 15 15 1/2 16 16 1/2 17 17 1/2 18

SERIES 3000 / 3100 PAGE 13. REGULAR ARM - CNTR. PIVOT INSTALLATION REGULAR ARM - CENTER PIVOT INSTALLATION! DOOR FRAME MUST HAVE DOOR STOP 11 1/4 Cntr. Pivot 2 1/4 1 5/16 Pivot Centerline Hole Instructions For Metal Doors with 1/8 surface thickness Drill #7 hole and tap for 1/4-20 x 5/8 M.S. (2 holes). For Metal Doors with less than 1/8 surface thickness or Wood Doors, Drill 3/16 pilot hole for #14 x 1 1/4 SMS (2 HOLES). Note: All hole locations shown above are located from centerline of pivot or hinge. A + B* See correct chart below for Pivot and arm information 2 3/4 & 3 3/4 C 90 Note: B dimension is from center line of pivot location to first door shoe screw. A dimension is the depth of reveal from face of frame to face of door. *2 3/4 Center Pivot Depth of Reveal A 1 1/2 2 2 1/2 3 3 1/2 4 4 1/2 5 5 1/2 Pivot to 1st Dr Shoe Screw B 11 1/8 11 1/8 11 1/8 11 1/8 11 1/8 11 1/8 11 1/8 11 1/8 11 1/8 Total Sec. Arm Length C 15 1/2 16 16 1/2 17 17 1/2 18 18 1/2 19 19 1/2 Secondary Rod Length -- 13 1/2 14 14 1/2 15 15 1/2 16 16 1/2 17 17 1/2 * 3 3/4 Center Pivot Depth of Reveal A 1 1/2 2 2 1/2 3 3 1/2 4 4 1/2 5 5 1/2 Pivot to 1st Dr Shoe Screw B 11 1/8 11 /18 11 1/8 11 1/8 11 1/8 11 1/8 11 1/8 11 1/8 11 1/8 Total Sec. Arm Length C 16 17 17 17 17 17 1/2 18 1/2 19 19 1/2 Secondary Rod Length -- 14 15 15 15 15 15 1/2 16 1/2 17 17 1/2 6 11 1/8 20 18 6 11 1/8 20 18

SERIES 3000 / 3100 PAGE 14. SLIDE ARM - BUTT-HINGE & CENTER PIVOT SLIDE ARM - BUTT HINGE AND CENTER PIVOT RH SHOWN BUTT HINGE CENTER PIVOT ( 3 3/4 ) 11 1/4 14 13 14 NON-BREAKOUT EMERGENCY BREAKOUT DOOR PREP FOR SLIDE TRACK Butt Hinge & Offset Pivot 12 1/4 For 2 3/4 & 3 3/4 Cntr Pivot 13 6 6 1 5/8 Hole Instructions For Metal Doors with 1/8 surface thickness drill holes with #7 drill bit and screw track to door with 1/4-20 x 5/8 machine screws. For Metal Doors with less than 1/8 surface thickness or Wood Doors drill 3/16 pilot hole for # 14 x 1-1/4 sheet metal screw.

SERIES 3000 / 3100 PAGE 15. DOOR SPEED TABLES Full Power Door opening time The door opening time to back check for a full power installation shall not be less than 1.5 sec. Door closing time Refer to the table below for size, weight, and times. Back check 80 90 Important Test all functions of the operator using operational switching devices such as press wall switches, sensors, or mats and the on/off switch. Latch check 10 Timing of door close T= Dv W 188lb-ft Door closing time from 90 to latch check where T=Time D=Door Width W=Door Weight W Door Weight in Pounds (kg) D Door leaf width 100 (45) 101 (46) 110 111 (50) 120 (54) 121 (55) Inches (mm) 140 (64) (50.0) 150 (68) 160 (73) 36 (914) & Under 2.0 sec. 36 (914) 2.3 sec. 42 (1067) 2.3 sec. 42 (1067) 2.7 sec. 48 (1219) 2.8 sec. 48 (1219) 3.2 sec. Low Energy Important Test all functions of the operator using operational switching devices such as press wall switches, sensors, or mats and the on/off switch. Timing of Door Swing T= Dv W 133lb-ft where 0 Latch check T=Time D=Door Width W=Door Weight 10 0 Back check Minimum opening times to back check or 80 or minimum closing times from 90 to latch check or 10 W Door Weight in Pounds (kg) D Door Leaf Width Inches (mm) 100 (45.4) 125 (56.7) 150 (68.0) 175 (79.4) 200 (90.7) 30 (762) 3.0 sec. 3.0 sec. 3.0 sec. 3.0 sec. 3.5 sec. 36 (914) 3.0 sec. 3.5 sec. 3.5 sec. 4.0 sec. 4.0 sec. 42 (1067) 3.5 sec. 4.0 sec. 4.0 sec. 4.5 sec. 4.5 sec. 48 (1219) 4.0 sec. 4.5 sec. 4.5 sec. 5.0 sec. 5.5 sec. Attention: These tables have been provided as a convenience for general setup. For complete specifications refer to ANSI A156.10 or ANSI A156.19 80 90

SERIES 3000 / 3100 PAGE 16. COVER INSTALLATION COVER INSTALLATION Install the cover into the top groove and rotate down until it snaps into the bottom lip of the header. Secure the cover with the 6-32 flat head screws across the bottom edge of the header. USE CAUTION USING A DRILL / DRIVER TO INSTALL THESE SCREWS, THEY MAY STRIP. COVER Install 6-32 screws here. Number of screw may vary.

SERIES 3000 / 3100 PAGE 17. SIGNAGE and CODE CONFORMANCE Signage Application Make sure all doors have proper signage as follows. An arrow sign (Fig. 1) shall be visible from the approach side of a swinging door mounted on the door at a height 58 inches ± 5 inches (1475± 127mm) from the floor to the center line of the sign. The sign shall be a minimum of 6 (150mm) in diameter, having a green circle surrounding a black arrow on a white backround. Fig. 1 An international DO NOT ENTER sign (Fig. 2) shall be visible from the side of the doors that would swing towards pedestrians attempting to travel in the wrong direction mounted on the door at a height 58 inches ± 5 inches (1475 ±125mm) from the floor to the center line of the sign. The sign shall be a minimum of 6 (150mm) in diameter, having a red circle with the wording DO NOT ENTER in red circle. Fig. 2 Swing doors serving both egress and ingress shall be marked with a decal, visible from the swing side of the door, with the words AUTOMATIC CAU- TION DOOR (SEE Fig. 3). The sign shall be mounted on the door at a height 58 inches ± 5 inches (1475 ± 125mm) from the floor to the center line of the sign. The sign shall be a minimum of 6 (150mm) in diameter and with black lettering on a yellow background. Fig. 3 Install all signage according to the information above and to ANSI/BHMA A156.10 or A156.19 standards. Make sure all appropriate signage is applied to the door. Adjust the door forces and speeds to the above mentioned standards that apply to the door being installed. (See Control adjustment diagram to at the back of this manual to accomplish this). Code Conformance Glass and glazing must comply with ANSI Z97.1. All electrical wiring must conform to National Electrical Code. Proper fingerguard must be applied to the hinge stile of the door. (Ref. UL325, Para. 27.12) All Knowing Act activation devices must be installed within eyesight of door motion. All public swing door installations must comply with either ANSI/BHMA A156.10 or A156.19.

SERIES 3000 / 3100 PAGE 18. CONTROL ADJUSTMENT DIAGRAM

SERIES 3000 / 3100 PAGE 19. CONTROL CONNECTION DIAGRAM