NAPAF - NAPBC HIGH PERFORMANCE AIRFOIL NAPAF AND BACKWARD CURVED NAPBC PLENUM FANS. 1 a Edition - subject to future integrations

Similar documents
ATZAF DOUBLE INLET AIRFOIL BLADEDBACKWARD CURVED CENTRIFUGAL FANS

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

CP 161 DAR - Art

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

Defining Innovation. backward curved FANs

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

DESIGN GUIDELINES FANS PAGE 1 of 7

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Twin City Fan & Blower

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

SECTION AXIAL HVAC FANS

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Product Specification Sheet Number: 319

SECTION CENTRIFUGAL HVAC FANS

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

WATER JACKET Low Voltage

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels

Twin City Fan & Blower

forward curved inline duct blowers

2015 AGRIGARDEN MACHINES

Complete HVAC Capability

2SP TWIN SCREW PUMPS ABS BV DNV GL LR RINA SERIES

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

TWIN THREE SCREW PUMPS SCREW PUMPS PUMP TYPE COMPONENT TYPE COMPONENT MODEL

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

Good Enough Never Is. Plug Fan SERIES 12

Centrifugal Utility Fans - SFD/SFB

RINGFEDER Shrink Discs RfN 4091

K SERIES SIDEWALL PROPELLER FANS

FIXED PITCH PROPELLER FANS

Centrifugal Filtered Supply Roof Blowers

RINGFEDER Shrink Discs RfN 4073

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

Product Specification Sheet Number: 305

Twin City Fan & Blower

Twin City Fan & Blower

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

LARGE MOTORS kv HIGH VOLTAGE HIGH EFFICIENCY & POWER

Turning Air Into Solutions. PLUG FANS TYPE BCPL

BAC, BAF, BAH Central Station Air Handlers

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

COLOMBO FILIPPETTI SPA

Vibration Isolators (6) Galvanized Wheel. Sealed Ball Bearing. Standard Duct Size Inlet Ring

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

VANEAXIAL & TUBEAXIAL FANS

to meet the updated test procedures outlined in the 1974 AMCA test code.

BEARING UNITS BEARINGS LINEAR MOTION PRODUCTS

AC Commercial Fans Edition. ErP ready

DIN 950. Spoked handwheels. d 2. l 3. d 3. l 1. Operating elements. Cast iron / Aluminium. SPECIFICATION Types

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

Defining Innovation. high efficiency industrial AiRfoiL fan TyPe haf BULLETIN 1150 May 2011

LEISTRITZ PUMPEN GMBH. Leistritz Screw Pumps & Systems L3MA 3 L. The new L3MA pump series according API 676 3rd. API 676 3rd. 6 3r

DPL/DPL-AF SERIES PLENUM FANS OPERATION INSTRUCTIONS AND PARTS MANUAL MODELS: DPL/DPL-AF-12, 13, 15, 16, 18, 20, 22, 24, 27, 30, 33, 36 GENERAL SAFETY

CS CS Automatic Shaping Center

RLM EVO High Performance - Plug Fans Impeller with true airfoil blades

Fixed Pitch Vane Axial Fan

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

DF / DFB / DFC DOUBLE WIDTH DOUBLE INLET FORWARD CURVED FANS

SILI PUMP, Your reliable one-stop supplier of marine pumps.

SECTION HVAC POWER VENTILATORS

HPA LARGER SERIES AC ELECTRIC MOTOR

FILTERED AIR SUPPLY FANS

OIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz

EXHAUST FANS CUD & CUB UPBLAST FANS

FAN & BLOWER CENTRIFUGAL FANS

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

xes y Gearbo Planetar /15 ( /15)

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

GENIX AUTOMATIC LIFTING STATIONS. Technical Sheet

DW - DW VOX SUBMERSIBLE SEWAGE PUMPS

COMMERCIAL DUTY PLENUM FANS

CENTRIFUGAL FANS. Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series

Short casing. Long casing (L version) Commercial premises

Industry best 5 year fan housing warranty, 1 year motor warranty

& 12" 96" / TABD CATALOG

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

Japanese Technology since Ego Circulators. Databook

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

WINDER. Impellers with higher efficiency and less sound level

Hison Axial Flow Fans

A-L A C AIR OIL COOLER LUFT/ÖL-KÜHLER OLAER COOLERS. Olaer A-LAC with A.C. motors for industrial hydraulic systems

TU-WAY ROOF VENTILATORS

Centrifugal Plenum Fan

SQUARE INLINE CENTRIFUGAL FANS

Hison Axial Flow Fans

MATTEI FOR TRANSIT APPLICATIONS. English RVM SERIES. Compressed air systems for modern transit vehicles

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

Transcription:

NAPAF - NAPBC HIGH PERFORMANCE AIRFOIL NAPAF AND BACKWARD CURVED NAPBC PLENUM FANS 1 a Edition - subject to future integrations

Contents Page 1. General description...2 2. Technical details...2 2.1. Structure...2 2.2. Impeller...2 2.3. Shaft...3 2.4. Bearings...3 8.1. NAPBC 10 T2, 11 T2; NAPAF 12 T2/T3 to 28 T2/T3; NAPAF 32 T1/T2 to 55 T1/T2 - Arr. 3P (Piggy back mounted motor)...45 8.2. NAPBC 10 T2, 11 T2; NAPAF 12 T2/T3 to 28 T2/T3; NAPAF 32 T1/T2 to 55 T1/T2 - Arr. 3BF (Base Frame mounted motor)...45 8.3. NAPBC 10 T2, 11 T2; NAPAF 12 T2/T3 to 28 T2/T3; NAPAF 32 T1/T2 to 55 T1/T2 - Arr. 3BFS (Base Frame Short mounted motor)...46 1

1. General description The high performance Plenum Fan NAP has been designed to handle clean air. It is able to achieve optimum aerodynamic performance with smooth air flow through the impeller, when not fitted within a conventional fan housing. fig.1 2. Technical details 2.1. Structure NAP Plenum Fans are manufactured in heavy gauge welded steel, reinforced with steel stiffeners and painted with an anticorrosive paint. From sizes 10 to 28, the structure is provided with a removable backframe that permits the wheel to be removed from the back of the fan (see fig.1 and fig.2 for details). From sizes 32 to 55, plenum fans are completely welded and the wheel can be removed from the top (see fig.5 and fig.6). The inlet cone is constructed in galvanized sheet steel or in black steel and painted, bolted onto the plenum and designed for optimal airflow through the impeller. 2.2. Impeller Plenum fans are available with a high performance airfoil wheel, NAPAF, or with high performance backward curved wheel, NAPBC. NAPAF: The airfoil impeller is manufactured with backward curved airfoil shaped blades, which are continuosly welded into position and painted finish (fig.3). The high performance Airfoil blade design is matched with the unique rotating diffuser where the air is slowed down and a static pressure regain takes place. The conseguence is a very wide operational working field with high efficiencies and low noise emissions. Airfoil wheels are available in wheel diameters from 12 to 55. fig.2 APBC: Backward curved wheel has single-thickness flat type blades. The use of the rotating diffusor is guaranty of high efficiency and low noise. Wheel diameters 10 and 11 (fig.4). All impellers are statically and dynamically balanced to a grade of Q=2,5 in accordance with DIN ISO 1940-1 and ANSI S2.19-1989. The hub bore is precision machined and incorporates a keyway and locking screw. fig.3 fig.4 2

2.3. Shaft All shafts are designed with a high safety factor, and with the critical speed well in excess of the maximum fan speed. Made with hardened steel, which is precision grounded and polished, and incorporates keyways for the wheel hub and sheaves. All shafts are painted for added protection prior to shipping. 2.4. Bearings fig.5 On the drive side from size 10 T2 to 28 T2, from 12 T3 to 22 T3 and from 32 T1 to 40 T1, the bearing is self-aligning single row deep groove ball type in pillow block cast iron housings (fig.7). The drive side bearing of 25 T3 and 28 T3 and from 32 T2 to 55 T2 is a double row roller bearing in a pillow block split cast iron housings (fig.8). For all plenum sizes the nondrive bearing is self-aligning single row deep groove ball type in pillow block cast iron housings (fig.7). All bearings have been selected to guarantee a minimum L50 life time of 200,000 hours (as per AFBMA standards). Bearing ratings are to be based on the fan's maximum operating speed and horsepower. These bearings are installed with a re-lubrication fitting. Operating temperatures range from -4 F to + 176 F (-20 C to + 80 C) for all plenums. fig.6 fig.7 fig.8 3

COMEFRI reserves the right to make any dimensional design changes which are part of their improvement programme. Necessary corrections are updated on our AEOLUS PLUS selection program. COMEFRI behält sich sämtliche Änderungen vor, die dem technischen Fortschritt dienen. Notwendige Korrekturen der Katalogdaten werden in unserem Auswahlprogramm AEOLUS PLUS berücksichtigt. Comefri se réserve la possibilité d apporter des modifications de dimensions sans aucun préavis ceci parce que ces informations font parties d un programme interne de dévelopment du produit. Les éventuelles variations et/ou corrections seront ajournés dans notre programme de sélection AEOLUS PLUS. La COMEFRI si riserva la possibilità di apportare modifiche dimensionali senza alcun preavviso ciò in quanto parte di un programma interno di sviluppo del prodotto. Le eventuali variazioni e/o correzioni saranno aggiornate nel nostro programma di selezione AEOLUS PLUS. Comefri SpA Via Buja, 3 I-33010 Magnano in Riviera (UD) Italy Tel. +39-0432-798811 Fax +39-0432-783378 E-mail: info@comefri.com Comefri USA, Inc Comefri Gmbh Comefri France S.A. 330 BilI Bryan Boulevard Hopkinsville, KY 42240 USA Tel. +1-270-881-1444 Fax + 1-270-889-0309 www.comefriusa.com E-mail: sales@comefriusa.com Landshuter str.55 84030 Ergolding Germany Tel. +49-871-43070-0 Fax +49-871-43070-40 www.comefri.de E-mail: info@comefri.de 10, Rue des Frères Lumière 69740 Genas France Tel. +33-4-72 79 03 80 Fax +33-4-78 90 69 73 E-mail: info@comefrifrance.fr Comefri UK Ltd Comefri Nordisk ApS Comefri China Ind. Co. Ltd. Carters Lane, 8 Kiln Farm Mileparken, 18 Suite 1201, North Tower, New Milton Keynes, MK11 3 ER DK 2740 Skovlunde World Times Center, 2191 Great Britain Denmark Guangyuan Rd. (E.) Guangzhou. Tel. +44-1908-56 94 69 Tel. +45-44-92 76 00 P.R.C. Fax +44-1908-56 75 66 Fax +45-44-92 55 33 Tel: +86 20 8773 1890/1891 Fax: +86 8773 1893 E-mail: sales@comefri.co.uk E-mail: mail.dk@comefri.com http://www.comefrichina.com E-mail: sales@comefrichina.com