Model 20 Constant Speed Blender : 115 Volt : 230 Volt. Instruction Manual. Updated 11/14/2017 Ver. 4.0

Similar documents
Updated 12/13/2013 Ver. 2.6

Atmospheric Consistometer # (115V) # (220V) Instruction Manual. Updated 1/25/2018 Ver. 6.0

Model 12BL Filter Press, Multi Unit. # Unit # Unit. Instruction Manual. Updated 08/25/2015 Ver. 2.0

Digital Resistivity Meter. Part No Instruction Manual. Updated 09/01/2015 Ver. 3.0

Electrical Stability Meter. Part No Instruction Manual. Updated 12/10/2015 Ver. 3.0

PHPA Polymer Concentration Kit. Part No. # Instruction Manual. Updated 1/23/2017 Ver. 2.0

HTHP Filter Press for Cement Testing with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual

HTHP Filter Press for Cement Testing with 175-mL, Double-Capped Test Cell and N 2 # : (115 V) # : (230 V) Instruction Manual

Methylene Blue Test Kit (115 Volt) (230 Volt) Instruction Manual. Updated 2/6/2017 Ver. 4.0

Benchtop HTHP Curing Chamber. Part No Instruction Manual. Updated 11/7/2017 Ver. 3.0

4-Unit HTHP Filter Press With Load Cell Option. # S VAC # S VAC # S-LC Load Cell Option. Instruction Manual

Laboratory Gas Flow Model # VAC # VAC. Instruction Manual. Updated 11/18/2014 Ver. 1.16

CRF-840 Rock-Fluid Centrifuge. Part No. # Instruction Manual. Updated 5/18/2018 Ver. 3.0

HTHP Filter Press with Threaded Cells for Drilling Fluids Testing. # : 115 Volt # : 230 Volt. Instruction Manual

Model 130 Benchtop Consistometer. # Standard # DAS - With Computer for Data Acquisition and Control. Instruction Manual

Instruction Manual Updated 8/3/2009 Ver. 1.1

Instruction Manual Updated 12/17/2013 Ver. 1.1

Permeability Plugging Tester - P.P.T. 2,000 PSI (13,800 kpa) F (260 C) Part No (115V) Part No (230V) Instruction Manual

Dynamic HTHP Filter Press With Magnetic Drive

Permeability Plugging Tester. # : 115 Volt # : 230 Volt. Instruction Manual

Twin Cell Ultrasonic Cement Analyzer. Part No Instruction Manual

Features. HTHP Filter Press for Drilling Fluids, 500 ml DRILLING FLUIDS EQUIPMENT

EP (Extreme Pressure) and Lubricity Tester

Ultrasonic Cement Analyzer. Single Cell: # Dual Cell: # Instruction Manual

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

Features. HTHP Filter Press for Drilling Fluid Testing DRILLING FLUIDS EQUIPMENT

Model Speed Viscometer. Features DRILLING FLUIDS EQUIPMENT

HTHP Consistometer with Data Acquisition System Model 100 (25,000 PSI, 400 F): DAS (Single Cell) / DAS (Dual Cell)

CW Optimizer Capacity Hat Kit. 75/80 and 80/40 Thunderbolt Vertical Antennas. for the DXE-7580-THK

OFI MODEL 60 ATMOSPHERIC CONSISTOMETER INSTRUCTIONAL MANUAL

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Parts Manual Vermeer/ McLaughlin Mud System 230P

Parts Manual Vermeer/ McLaughlin Mud System 230P

TL-105-D COLUMN HEATER

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

instructions ZCM ZCM START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax

MAGPOWR Spyder-Plus-S1 Tension Control

FR1118- P10. User s Manual

Diffuser Heater Installation for DRS Units

92831 TEL: (714) FAX:

OFI MODEL 130 HTHP BENCHTOP CONSISTOMETER INSTRUCTIONAL MANUAL

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

WARRANTY POLICY FOR LD SERIES LABEL DISPENSERS REPAIR POLICY

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

POWER. Switch opening. Enter/Exit Menu Menu Scroll Increase/Decrease Setpoint GCE SERIES MODEL 10AFE MODEL 20AFE

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

SAFTRONICS DF8 PLUS SERIES

instruction ZCM 100 ZCM 200 START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax

HR-20P Pneumatically Controlled Pressure Regulator

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Polaris 1000 User s Manual

RESOURCE GUIDE. P r o d u c t M a n u a l. START International

Model 809 Diaphragm Gauge Controller

Innovatech User Manual. Predator 2400 T H E S U R F A C E P R E P A R A T I O N S P E C I A L I S T S

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

Type Maxi Mix III Rotary Shaker

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Read this entire manual before operation begins.

IAQ-CALC TM Indoor Air Quality Meter

Toshin-Cho Itabashi-ku Tokyo, Japan Tel Fax /06

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

INSTALLATION INSTRUCTION & OWNER S MANUAL

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Parkit360 Force. Owner s Manual V2.6.2

HPV 100 Hydraulic Elevator Soft-Starter Technical Manual

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

Model 30GCE Low-Temp Oven POWER. Switch opening. View Setpoint Increase Setpoint Decrease Setpoint (3 sec.) Enter/Exit Menu Levels GCE SERIES

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

ECLIPSE Laundry Dispenser Controller


ODY-05-2 VOLTMETER FOR REMOTE MONITORING

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

SPC Series. Digital Scale. Operation Manual

INSTRUCTIONS FOR INSTALLING AND OPERATING THE UNIVERSAL AUTOSYNC MODEL ASPSS DUAL COMPRESSOR SEQUENCER CONSOLE S/N 1638 AND ABOVE

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Exhaust Fan Flow Meter. Operation Manual. The ENERGY CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

FORCE 5K & 10K 8AM-6PM EST OFFICE HOURS (WEEKDAYS) CALL US TOLL-FREE:

Operation and Maintenance Manual for Multipurpose Actuators. 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator

DYNAMOMETER CONTROLLER MODEL 5220 INSTRUCTION AND REFERENCE MANUAL

REMOVAL OF FACTORY GAUGE ULTRA FLHT & FLHX (STREET GLIDE

Parts Manual Vermeer/ McLaughlin V750 Vacuum Machine (Serial #7G G )

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

AD-7 THERMAL INDICATING AMMETER

1000W RADIOMETRIC POWER SUPPLY

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Users Guide for Ac-sync

II DISTRIBUTION & SUBSTATION TYPE C

CRD610 Automatic Fitting Inserter

StormPro BA Series Sump Pump

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Parr Instrument Company

Transcription:

Model 20 Constant Speed Blender 120-65: 115 Volt 120-65-1: 230 Volt Instruction Manual Updated 11/14/2017 Ver. 4.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300 Fax: 713.880.9886 www.ofite.com Copyright OFITE 2013

Table of Contents Intro...2 Description...2 Specifications...3 Components...3 Installation...7 Operation...8 Manual Mode...8 Variable Mode...9 Auto Mode...9 Timer...10 Speed Controller...10 Pid Parameters... 11 Warranty and Return Policy...12 OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 1

Intro Description OFITE s Model 20 Constant Speed Blender was designed to prepare well cements for testing according to the guidelines stated within API Specification 10. Research has demonstrated that the properties of well cements are highly dependent upon mixing procedures. In addition, studies have indicated that when constant speed blenders/mixers are used, data obtained from thickening time tests has greater reproducibility and generally correlates better with data obtained from other laboratories. The Model 20 was designed to provide a means of consistently preparing cement slurries for testing purposes and can be utilized to mix cements according to the procedures stated by the API. The proper amount of mix water is carefully weighed and poured into the mixing container of the blender. The rotational speed is set to 4,000 rpm and allowed to stabilize at this speed. The TIMER switch is pressed and the cement is immediately added to the mix water. The cement should be uniformly added to the water in less than 35 seconds. After 35 seconds the rotational speed is automatically increased to 10,000 rpm and the slurry is mixed an additional 50 seconds. A microprocessor is utilized to maintain the rotational speed within the recommendations established by the API and is independent of fluctuations in line voltage and the viscosity of the cement slurry. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 2

Components Consumables: #122-201 Blending Assembly, 4 Liter #122-204 Bottom Gasket Replacement Parts: #122-205 Lid for 4-Liter Container #122-206 Container, Stainless Steel, 4 Liter For 120-65, 115 Volt: #120-65-019 Waring Blender with Exciter Gear and Magnetic Pickup #152-37 AC Power Cord For 120-65-1, 230 Volt: #122-075 Fuse, 7 Amp #122-077 Fuse, 10 Amp #152-38 AC Power Cord Optional: #120-66 Spare Parts Kit, 115 VAC #122-012 Fuse, 1 Amp, ¼" 1¼", Qty: 2 #122-074 Fuse, 4 Amp, 5 mm 20 mm, Qty: 2 #122-201 Blending Assembly, 4 Liter, Qty: 6 #122-204 Bottom Gasket, Qty: 6 #122-205 Container Lid, 4 Liter #122-206 Stainless Steel Container, 4 Liter Specifications Hardened stainless steel mixing blades Stainless steel 4-liter mixing container Two preset mixing speeds and variable speed (16,000 RPM Maximum) Rotational speed is maintained at setpoint with microprocessor Timing relays automatically control mixing times at required rpm Digital instrumentation provides excellent readability Crated Size: 30 24 44 inches (76.2 60.9 111.8 cm) Crated Weight: Approximately 180 pounds (81.65 kg) OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 3

1 2 9 10 3 4 6 5 7 8 11 16 12 13 14 15 1. Rotational Speed Display This display show the speed of the blade. Multiply the value displayed here by 10 to determine the actual RPM of the blade. 2. Timer Display (Seconds) 3. Edit Setpoint 1 / Increase Setpoint Digit Press this button to change the timer value of Setpoint 1. When editing a setpoint value, this button increases the first digit of the value by 1. 4. Edit Setpoint 2 / Increase Setpoint Digit Press this button to change the timer value of Setpoint 2. When editing a setpoint value, this button increases the second digit of the value by 1. 5. Increase Setpoint Digit This button increases the fourth digit of the setpoint value by 1. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 4

6. Increase Setpoint Digit This button increases the third digit of the setpoint value by 1. 7. Enter Button Press this button to store the Setpoint value in memory. 8. Timer Reset Press this button to reset the timer to zero. 9. Keypad: VAR This button accesses the PID Parameter Control Menu. 10. Keypad: SETPT Press this button to change the rotational speed of Setpoint 1 or Setpoint 2. 11. Keypad: ENTER Press this button to store the Setpoint value in memory. 12. Two-Way Switch: ON - OFF This switch provides power to the unit. 13. Two-Way Switch: MAN/AUTO - Variable This switch determines the operating mode of the unit. If it is set to MAN/AUTO, the MAN - AUTO switch (15) becomes active. If it is set to VARIABLE, the unit will be in Variable Mode. 14. Three-Way Switch: MAN - AUTO This switch remains inactive unless the MAN/AUTO - Variable switch (13) is set to MAN/AUTO. It toggles the operating mode between Manual Mode and Auto Mode. If it is in the center position, the unit will not rotate. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 5

15. Three-Way Switch: ST PT 1 - ST PT 2 This switch remains inactive unless the MAN/AUTO - Variable switch (13) is set to MAN/AUTO and the MAN - AUTO switch (15) is set to MAN. It toggles the rotational speed between 4,000 RPM (ST PT 1) and 10,000 RPM (ST PT 2). If it is in the center position, the unit will not rotate. 16. Potentiometer This knob remains inactive unless the MAN/AUTO - Variable switch (13) is set to Variable. It provides greater control over the rotational speed of the unit. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 6

Installation 1. Carefully remove the unit from the packing box and place it on a counter safely away from sinks and other possible hazards. 2. Place the blending assembly on the base of the unit. 3. Plug the power supply cord into the port underneath the cabinet housing labeled BLENDER. 4. Plug the transducer cable into the center port and fasten in place with the two clamps and screws provided. Do not over tighten. 5. Finally, plug the power supply cord into a suitable AC power supply. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 7

Operation The unit has three operating modes: Manual, Variable, and Auto. The MAN/AUTO - Variable switch (13) and the MAN/AUTO switch (15) set the mode. 1. To set the unit to Manual Mode, set the MAN/AUTO - Variable switch (13) to MAN/AUTO and the MAN - AUTO switch (15) to MAN. 2. To set the unit to Auto Mode, set the MAN/AUTO - Variable switch (13) to MAN/AUTO and the MAN - AUTO switch (15) to AUTO. 3. To set the unit to Variable Mode, set the MAN/AUTO - Variable switch (13) to Variable. Before turning the unit on, be sure to set the MAN/AUTO switch (15) and the ST PT 1 / ST PT 2 switch (14) to the center position and turn the Potentiometer (16) fully counter-clockwise. Operation Manual Mode 1. Place the mix water into the mixing cup and place the lid on top of the container. 2. The MAN/AUTO - Variable switch (13) should be in the MAN/AUTO position. The MAN/AUTO switch (15) should be in the MAN position. 3. Place the ST PT 1 / ST PT 2 switch (14) to the ST PT 1 position to start the unit. When you initially start the unit, the rotational speed may exceed the setpoint, but will stabilize within a few seconds. 4. After stabilization, you have 35 seconds to add the cement to the mix water and cover the container with the lid. Reset the timer to zero by pressing the Reset Button (8). 5. After 35 seconds, increase the rotational speed by setting the ST PT 1 / ST PT 2 switch (14) to ST PT 2. 6. After mixing the cement an additional 50 seconds, stop the blender by setting the ST PT 1 / ST PT 2 switch (14) to the center position. 7. Return the MAN/AUTO switch (15) to the center position. 8. After mixing is complete, clean the blending cup and lid as soon as possible to prevent any cement from building up on the container. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 8

Operation Variable Mode 1. Place the mix water into the mixing cup and place the lid on top of the container. Ensure that the potentiometer control knob is in the fully counter-clockwise position. 2. Make certain that the ST PT 1 / ST PT 2 switch (14) is in the center position. Place the MAN/AUTO - VARIABLE (13) switch in the VARIABLE position. 3. Increase the rotational speed of the blender by turning the control Potentiometer (16) clockwise. 4. Reset the timer to zero by pressing the reset button (8). 5. After mixing is complete, clean the blending cup and lid as soon as possible to prevent any cement from building up on the container. Operation Auto Mode 1. Place the mix water into the mixing cup and place the lid on top of the container. 2. Make certain that the ST PT 1 / ST PT 2 switch (14) is in the center position. Place the MAN/AUTO - VARIABLE switch (13) to the MAN/AUTO position. Place the MANUAL/AUTO switch (15) switch to the AUTO position. Once the switch is placed into the AUTO position, the blender should start to accelerate. If the blender does not accelerate, reset the timer by pressing the reset button (8). When you initially start the unit, the rotational speed may exceed 4,000 RPM, but will stabilize at 4,000 RPM within a few seconds. 3. After stabilization, reset the timer to zero again and immediately begin adding the cement. You have 35 seconds to add the cement to the mix water and place the lid on the container. After 35 seconds the timer will automatically increase the rotational speed to 10,000 rpm. Ensure that the cement is added to the mix water and that the lid is placed on the container in less than 50 seconds. 4. After mixing the cement at 10,000 rpm for 50 seconds the timer will automatically stop the blender. 5. After mixing is complete, clean the blending cup and lid as soon as possible to prevent any cement from building up on the container. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 9

Operation Timer The timer is continuously on whenever power is applied to the unit. The unit will measure elapsed time to its maximum value and then stop at setpoint 2. By default, setpoint 1 is set to 35 seconds and setpoint 2 is set to 85 seconds. These values conform to the guidelines established in API Specification 10. To change these values, do the following: 1. Press 1 (3) or 2 (4) to change setpoint 1 or setpoint 2 respectively. 2. The display will show the current setpoint value. The four buttons beneath the display (3-6) each increase a separate digit of the setpoint value. The digits will scroll from 0 to 9 and then return to 0. 3. When you reach the correct setpoint value, press the enter button (7) to store it in the timer's memory. Operation Speed Controller From the factory, setpoint 1 is set to 4,000 rpm and setpoint 2 is set to 10,000 rpm. These values conform to the guidelines established in API Specification 10. To change these values, do the following: 1. Press SETPT (10) to activate the speed control menu. 2. Use the arrow keys to scroll to either SETPOINT 1 or SETPOINT 2. 3. Press ENTER (11). 4. Key in the numeric value (rotational Speed) of the new setpoint with the keypad. 5. Press ENTER (11) to store the new value into the controller s memory. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 10

Operation Pid Parameters For optimum performance, it may be necessary to change the PID parameters within the controller. To tune the controller, do the following: 1. Operate the unit in Manual Mode with a typical fluid within the container. Toggle between 4,000 rpm and 10,000 rpm and watch for over or undershoot. If there is significant overshoot access VARIABLE 9 and reduce the value by 4. To access VARIABLE 9 press the VAR (9) key, press 9, and then press ENTER (11). Key in the new value and press ENTER (11) to store it into memory. If there is no overshoot or undershoot, but the response was slow, increase the value of Variable 9 by 4. Repeat the above procedure, changing the value of VARIABLE 9 until there is minimal overshoot and the ramp is smooth. Note that to fine tune the controller, the value can be incremented in steps of 1 or 2 and not necessarily a value of 4. 2. Run the controller at 10,000 rpm. Increase VARIABLE 10 by 4 and watch for any oscillations around the setpoint. If no oscillations occur increase Variable 10 by 4 until oscillations begin. 3. After the onset of oscillations, reduce VARIABLE 10 by 4. 4. Repeat steps 2 and 3 until minimal over and undershoot occur. This is a trial and error process. After each change, record the setting and its result. Variable 9 and 10 are initially set to 10 and 8 respectively. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 11

Warranty and Return Policy Warranty: OFI Testing Equipment, Inc. (OFITE) warrants that the products shall be free from liens and defects in title, and shall conform in all respects to the terms of the sales order and the specifications applicable to the products. All products shall be furnished subject to OFITE s standard manufacturing variations and practices. Unless the warranty period is otherwise extended in writing, the following warranty shall apply: if, at any time prior to twelve (12) months from the date of invoice, the products, or any part thereof, do not conform to these warranties or to the specifications applicable thereto, and OFITE is so notified in writing upon discovery, OFITE shall promptly repair or replace the defective products. Notwithstanding the foregoing, OFITE s warranty obligations shall not extend to any use by the buyer of the products in conditions more severe than OFITE s recommendations, nor to any defects which were visually observable by the buyer but which are not promptly brought to OFITE s attention. In the event that the buyer has purchased installation and commissioning services on applicable products, the above warranty shall extend for an additional period of twelve (12) months from the date of the original warranty expiration for such products. In the event that OFITE is requested to provide customized research and development for the buyer, OFITE shall use its best efforts but makes no guarantees to the buyer that any products will be provided. OFITE makes no other warranties or guarantees to the buyer, either express or implied, and the warranties provided in this clause shall be exclusive of any other warranties including ANY IMPLIED OR STATUTORY WARRANTIES OF FITNESS FOR PURPOSE, MERCHANTABILITY, AND OTHER STATUTORY REMEDIES WHICH ARE WAIVED. This limited warranty does not cover any losses or damages that occur as a result of: Improper installation or maintenance of the products Misuse Neglect Adjustment by non-authorized sources Improper environment Excessive or inadequate heating or air conditioning or electrical power failures, surges, or other irregularities Equipment, products, or material not manufactured by OFITE Firmware or hardware that have been modified or altered by a third party Consumable parts (bearings, accessories, etc.) Returns and Repairs: Items being returned must be carefully packaged to prevent damage in shipment and insured against possible damage or loss. OFITE will not be responsible for equipment damaged due to insufficient packaging. Any non-defective items returned to OFITE within ninety (90) days of invoice are subject to a 15% restocking fee. Items returned must be received by OFITE in original condition for it to be accepted. Reagents and special order items will not be accepted for return or refund. OFITE employs experienced personnel to service and repair equipment manufactured by us, as well as other companies. To help expedite the repair process, please include a repair form with all equipment sent to OFITE for repair. Be sure to include your name, company name, phone number, email address, detailed description of work to be done, purchase order number, and a shipping address for returning the equipment. All repairs performed as repair as needed are subject to the ninety (90) day limited warranty. All Certified Repairs are subject to the twelve (12) month limited warranty. Returns and potential warranty repairs require a Return Material Authorization (RMA) number. An RMA form is available from your sales or service representative. Please ship all equipment (with the RMA number for returns or warranty repairs) to the following address: OFI Testing Equipment, Inc. Attn: Repair Department 11302 Steeplecrest Dr. Houston, TX 77065 USA OFITE also offers competitive service contracts for repairing and/or maintaining your lab equipment, including equipment from other manufacturers. For more information about our technical support and repair services, please contact techservice@ofite.com. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 12