Door Operator Conversion Package: Type M to PM/SSC or HPM/SSC with Board 1Ø4

Similar documents
Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3)

Complete Installation Manual for the ECI LCD Board

Complete Installation Manual for the ECI LCD Closed Loop Door Operator Board

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ECU. Speed Switch Manual. Contents. ECU is a registered trademark of Engineering Concepts Unlimited Inc.

Illustrated Parts List for GPU-400

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

RP-4000 Reserve Power Control

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

TRAC-3 TENSION READOUT AND CONTROL

Boston Gear Ratiotrol DC Motor Speed Control

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

MODEL ELC-12/40-CVM-D BATTERY CHARGER

CURTIS TRANSISTOR MOTOR CONTROLLER

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

Features IN THIS CHAPTER

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

Understand how soft starters operate.

Surepowr Series 100 Installation Manual

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

Horizontal Circuit Switchers

Horizontal Circuit Switchers

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

PM300E Voltage Regulator Instruction Manual

CN0055 & CN0055B DC to DC NEGATIVE RESISTANCE SPEED CONTROL

CONTROL FEATURES AVAILABLE OPTIONS

INSTALLING, OPERATING AND MAINTAINING THE MODEL D1028 COMPUTER INPUT BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-225

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

EA07. Generator Automatic Voltage Regulator Operation Manual

SECTION 2 - PROCEDURES. Features. 2.6 MOTOR CONTROLLER. Modes of Operation JLG Lift 2-5

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

MOVFE 2500 LINEAR DOOR OPERATOR MECHANICAL MANUAL GAL CANADA

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

Troubleshooting Guide for N1225-1/N1237-1/N Alternators

MaxPak Plus Analog DC V S Drive

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

Troubleshooting Bosch Proportional Valves

OnCommand Troubleshooting Guide Hayward Industries

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

XENON POWER SUPPLY for 10 kw Britelight Lamphead

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

T O C Car Signal Components Coils Door Equipment Key Switches Safety Edge Equipment Door Operator Equipment GAL Relay Parts Wheels

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Coleman Air C440-HVM 440 Amp Diversion Controller Version 3.2

5001TCP SPEED CONTROLLER

SDC,Inc. SCR-Regenerative Ac Drive

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

ESD5500E Series Speed Control Unit

Advanced Test Equipment Rentals ATEC (2832)

Controls and Instruments

5600 Series Power Operator Installation and Instruction Manual

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

THE MODEL D1025 MKII BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-276

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

Trademarks All trademarks or registered product names appearing in this document are the exclusive property of the respective owners.

Fincor Series 2230 MKII/2240

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

INSTALLATION MANUAL. for. D3000 Door Operator Fair Oaks Blvd., Sacramento, CA

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

ARMOR QUICK LOCATOR GUIDE. Belts , 380 Brake Components Brushes Capacitors Car Signal Components...

Electrical Components

Coleman Air Diversion Controller Model C40

SD Bendix ET-2 Electronic Treadle DESCRIPTION OPERATION

COM Overcurrent Relay

Installation and Operation Manual. *See page 6 for CE Information

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Allen-Bradley HP Inverting Fault Circuit Breaker Kit

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

BLY34MDA Series. 50V, 30A Brushless Controller / Motor. User s Guide E Landon Drive, Anaheim, CA

SECTION MOTOR CONTROL

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Installation & Operation Manual

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

CN0124 STEP MOTOR DRIVE

Filtered PWM Speed Control for Permanent Magnet DC Motors

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

MDC Series

Basics of Control Components

KBIC SCR DC Motor Speed Controls

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

VA-715x Electric Valve Actuator

Transcription:

SPARES CENTER Door Operator Conversion Package: Type M to PM/SSC or HPM/SSC with Board 1Ø4 PAA8-606 (4/98) 63113-418 (R0)

Type M to PM/SSC or HPM/SSC Purpose This product instruction provides a brief description of the features and components of the Type M (non-solid state) to PM/SCC or HPM/SSC (high performance) with Board 1Ø4 (solid state) Door Operator conversion package. This product instruction also provides Field Personnel with information on conversion procedures, operational checks and adjustments, and diagnostic procedures. A606-001 (7/97) 1998 MOLINE ACCESSORIES COMPANY This volume is not intended for distribution, and not approved for use as a source of information for any purpose or procedure. All rights reserved. No portion of this volume may be reproduced or used in any manner without written permission from Moline Accessories Company -- 107 18th Street; Moline, IL 61265 2 PAA8-606 (4/98)

Door Operator Conversion TABLE OF CONTENTS Purpose 2 Safety 4 Description of PM/SSC door operator with Board 1Ø4 5 Converting door operator components 6 Remove Type M components.............................. 6 Install Board 1Ø4 components............................ 7 Wire Board 1Ø4 components............................. 8 Install new cover........................................ 10 Adjusting door operator control Board 1Ø4 11 Measure current (optional)................................ 13 Set potentiometers...................................... 13 Adjust door speeds...................................... 14 Adjust door closing force.................................. 16 Adjust nudge speed..................................... 16 Set microswitch cams.................................... 17 Replacement Parts 18 3

Type M to PM/SSC or HPM/SSC Safety Participate in the successful conversion procedures of MAC Car Door equipment know the safety hazards related to any procedure, know what equipment is required, and know what tools and materials you should plan to have available beforehand. Always consider safety first. Use a circuit tester on circuits prior to working on them. Avoid pinch points when handling materials. Make sure there is adequate lighting in the work space. Be aware of all tripping hazards. Make certain electrical outlets are protected with a ground fault circuit interrupter (GFCI). When working on the car top, always be aware of where you are in relationship to edge of car top. A606-002 (7/97) 024 (3/97) 066 (2/97) 4 PAA8-606 (4/98)

Door Operator Conversion Description of PM/SSC door operator with Board 1Ø4 The PM/SSC is a standard performance door operator, most commonly used, with a speed of 1FPS to 2 FPS (average 1.5 FPS, peak 2.5 FPS). The PM/ SSC door operator with Board 1O4r has the following operations and features: Door control power Current control Speed & travel limits Acceleration & deceleration Diagnostics & switch adjusting Auxiliary piloting Door control power. PM/SSC door operator control uses a low voltage permanent magnet DC motor. The DC motor is powered by pulse width modulated power (high speed switching - 20,000 hz). The motor responds to average voltage of high frequency pulses, and not individual pulses. Current control. PM/SSC door operator control has a current sensing circuit in both open and closed directions to supply feedback to the speed control circuit. This current sensing circuit regulates closing door force, and open/stall current caused by a hooked interlock. The current sensing circuit also guarantees that PM/SSC door operator control relay contacts do not break or make when motor armature current is present helping to prevent damage to relay contacts. Motor direction is controlled by reversing the armature connection using a conventional relay system. Diagnostics & adjusting switches. PM/SSC door operator control has two small toggle switches mounted on the common circuitboard. The TEST/RUN switch and O-OFF-C switch are used to: Signal door opening or closing from the car top duringdiagnostics and adjusting Disconnect the door open and close signals De-activate the internal shutdown timer Auxiliary piloting. The PM/SSC door operator control also has a Form C Open and a Form C Closed relay contact for auxiliary piloting. The Type M to PM/SCC door operator conversion kit contains the following. Door control with Board 1Ø4 /motor assembly PM/SSC bottom cover Cover (top) 13 connector cable for wiring microswitches Mounting hardware A606-003 (7/97) Speed & travel limits. PM/SSC door operator control selects speed and travel limits with cam operated microswitches. These microswitches operate relays tied into the speed direction circuits. Acceleration & deceleration. PM/SSC door operator control has an internal soft-start circuit which regulates smooth acceleration and deceleration. Softstart circuit allows average motor voltage to change gradually when speeds change. Door control with Board 1Ø4 /motor assembly 5

Type M to PM/SSC or HPM/SSC Converting door operator components Complete the following to convert Type M door operator components to PM/SSC Board 1Ø4 door operator components. Removing Type M components Installing Board 1Ø4 components Wiring Board 1Ø4 components Installing new cover REMOVE TYPE M COMPONENTS 1. Turn OFF electrical power to the door operator. 2. Remove existing microswitch cover. 3. Remove belt (1) from motor sheave (2) and door operator sheave (3). Save belt for use with conversion kit. 4. Remove motor mounting hardware and remove old motor (4) and mounting plate. 5. Disconnect controller wires at door operator, and tag the wires for identification. Remove terminal board. 6. Remove all wiring to the microswitches - including jumpers. 7. Disconnect wires at controller, and tag the wires for identification. Make sure the identification tags at the door operator and controller match. Older door operators could have cast spoke sheaves. 6 PAA8-606 (4/98)

Door Operator Conversion INSTALL BOARD 1Ø4 COMPONENTS 1. Install bottom cover (5). 2. Install Board 1Ø4 conversion kit assembly (6) with mounting hardware provided. 3. Install belt (1) on motor sheave (7) and door operator sheave (3). Make sure motor sheave and door operator sheave are aligned when installing belt. 7

Type M to PM/SSC or HPM/SSC WIRE BOARD 1Ø4 COMPONENTS 1. Plug molex end of new 13 connector cable into CN1 on Board 1Ø4. 2. Route cable under cams and wire into microswitch terminals. If DSD is required, add DSD switch connections. If DSD is not required, tape off connectors 12 and 13. Input & Output Terminals Required for door to operate L1A to L2A 120VAC @ 500VA input. If one of input lines is grounded, it should be connected to L1A. DO3 to L1A Open limit signal. A relay across these terminals de-energizes when open limit microswitch is actuated. Relay is energized at all other times. DO7 to L1A Signal to close. When a relay contact across these terminals makes up, doors should close. DO10 to L1A Signal to open. When a relay contact across these terminals makes up, the doors should open. DO17 to L1A Close limit signal. A relay across these terminals de-energizes when close limit microswitch is actuated. Relay is energized at all other times. Optional DO4 to DO7 Reduced speed closing signal. When doors have a signal to close, and a relay contact across these terminals makes up, door speed is controlled by N potentiometer. F NC NO Auxiliary C relay switching contact. C Designates a Form C contact on a 1-C relay. F NC NO Auxiliary O relay switching contact. O Designates a Form C contact on 1-O relay. DSD to SS Optional - Used on some projects for load balancing or other customer requirement. A606-005 (3/98) 8 PAA8-606 (4/98)

Door Operator Conversion 3. If a Miprom controller is used, DO3, DO4, DO7, DO10, DO17, and optional DSD, SS terminals on TB1 connect to the same terminals on Miprom controller. power terminals L1A and L2A are also connected to like terminals on Miprom controller. 4. If controller is other than a Miprom, follow signal requirements outlined in Input & Output Terminals chart. DOL and DCL are not required if Miprom control is used. They MAY be required if any other type of control is used. 9

Type M to PM/SSC or HPM/SSC INSTALL NEW COVER 1. Drill two 21/64 inch [8.3 mm] diameter holes (8) in each end of the base assembly. (Two holes in each end of base assembly for a total of four holes.) Centers of holes are located 1 inch [25.4 mm] down from top of end plate and.53 inch [13.5 mm] from side of end plate. Center to center of holes is 6-3/4 inches [171.5 mm] 2. With the threaded end to the inside, install four 5/ 16-18 x 1-1/4 inch hex head cap screws (9) through the 21/64 inch [8.3 mm] diameter holes. 3. Secure screws with four 5/16 inch flat washers (10), four 5/16 inch lock washers (11), and 5/16 inch hex nuts (12). 4. Position new cover on 5/16-18 x 1-1/4 inch hex head cap screws (9) and secure cover with four 5/ 16 inch flat washers (10), four 5/16 inch lock washers (11), and 5/16 inch wing nuts (13). A606-004 (7/97) 10 PAA8-606 (4/98)

Door Operator Conversion Adjusting door operator control Board 1Ø4 Adjust door operator control Board 1Ø4 as follows. Measure current (optional) Set potentiometers Adjust door speeds Adjust door closing force Adjust nudge speed Set microswitch cams Board Board 1Ø4 could be damaged if adjustment instructions are not followed carefully. If you cannot complete any of procedures as described, stop and request assistance. A604-017 (2/97) Board 1Ø4 Toggle switches To adjust and service door control, use two toggle switches on door operator control Board 1Ø4 TEST-RUN switch and O-OFF-C switch. TEST-RUN. TEST-RUN switch is normally in RUN position. When TEST-RUN switch is in TEST position, it disconnects normal open and close input signals from door control, and switches the O-OFF-C toggle switch into the circuit. O-OFF-C. O-OFF-C switch is normally in OFF (center) position. OFF position does not indicate input power has been removed. It only indicates no signal to open or close when TEST-RUN switch is in TEST position. A604-SI5 (2/97) 11

Type M to PM/SSC or HPM/SSC Toggle switches To adjust and service door control, use two toggle switches on door operator control Board 1Ø4 TEST-RUN switch and O-OFF-C switch. TEST-RUN. TEST-RUN switch is normally in RUN position. When TEST-RUN switch is in TEST position, it disconnects normal open and close input signals from door control, and switches the O-OFF-C toggle switch into the circuit. O-OFF-C. O-OFF-C switch is normally in OFF (center) position. OFF position does not indicate input power has been removed. It only indicates no signal to open or close when TEST-RUN switch is in TEST position. A604-SI5 (2/97) Board 1Ø4 12 PAA8-606 (4/98)

Door Operator Conversion MEASURE CURRENT (OPTIONAL) CAUTION: Do not install an ammeter in power supply line. Current measurements are not required to adjust door operator control Board 1Ø4. If necessary, measure current as follows. SET POTENTIOMETERS Make sure all potentiometers are set to ZERO, except P8. Do not set potentiometer P8. It is factory-set and sealed. These multi-turn potentiometers require 25 turns to traverse their complete range. A604-019 (3/97) 1. Connect a voltmeter to resistor R2 (.1 Ohm 5 watt resistor) located between heat sinks Q2 and D2. Viewing from TB1 side of control board, right side of resistor R2 is (-) and left side of resistor R2 is (+). 2. Set voltmeter to a low range 1 volt or 2.5 volt. 3. Read measurement with following in mind. 1 volt on meter indicates 10 amps of current..5 volt on meter indicates 5 amps of current. A604-018 (2/97) 13

Type M to PM/SSC or HPM/SSC ADJUST DOOR SPEEDS 1. Disconnect and tag-out power. 2. Remove door operator cover and close doors. 3. Set switches and potentiometer in following positions. All speed control potentiometers - fully counter-clockwise. C.C.L. potentiometer - Fully clockwise. TEST-RUN switch - TEST position. O-OFF-C switch - OFF (center) position. Two position jumper J4 - just to right, and slightly above, R01 relay. (Standard position if one pair of wires is present at TB3. High Performance if two pairs of wires are present at TB3.) 4. Apply power. Toggle O-OFF-C switch to O position. LED6 next to PL potentiometer illuminates, indicating doors are in PL zone. 5. Turn PL potentiometer clockwise until doors begin to open. When PL microswitch drops, LED next to PL potentiometer goes out, and LED next to OF potentiometer illuminates. 6. Turn OF potentiometer clockwise, just enough to move doors through OF speed zone. When OSDL microswitch drops, LED next to OF potentiometer goes out, and LED next to OS potentiometer illuminates. 7. Turn OS potentiometer, just enough to move door through OS speed zone. When OL cam activates OL microswitch, LED next to OS potentiometer goes out. Doors should be fully open. 8. Toggle O-OFF-C switch to C position. LED next to CF potentiometer comes on. 9. Turn CF potentiometer clockwise until doors begin to move. When CSDL microswitch is dropped by its cam, LED next to CF potentiometer goes out and LED next to CS potentiometer illuminates. 10. Turn CS potentiometer clockwise until CL microswitch is actuated by its CAM. LED next to CS potentiometer goes out. Doors should open and close at slow speed. If doors do not fully open or close within 20 to 30 seconds, internal timer removes motor power and LED 7 is lit. If board senses over 5 amps, power shuts down and LED 7 is lit. 11. Using speed zone potentiometer and CAM settings, adjust door speeds for desired performance. Green LED s indicate which speed control potentiometer is controlling door speed. Increase door speed turn potentiometer clockwise Decrease door speed turn potentiometer counterclockwise Do not set potentiometer P8. It is factory-set and sealed. A604-020 (4/97) TIP: If doors do not operate smoothly, particularly on slower moving doors, it may help to remove jumper J3. This eliminates dynamic braking, and allows a smoother transition between speeds. A604-SI6 (2/97) 14 PAA8-606 (4/98)

Door Operator Conversion 15

Type M to PM/SSC or HPM/SSC ADJUST DOOR CLOSING FORCE 1. Toggle TEST-RUN switch to TEST position. 2. Stop doors at mid-point in closing direction by toggling O-OFF-C switch to OFF position. 3. Turn CCL (close current limit) potentiometer fully counter-clockwise until doors stall. 4. Turn CCL potentiometer clockwise until desired door close operation is achieved. Door closing force should be less than 30 pound maximum allowed by Code. 5. To check door pressure, physically stall door at midpoint in closing direction. 6. Place rubber end of a pressure gauge (1) on edge of power-driven car door (3). Read pounds of force (2) on gauge and record results. 7. Open and close doors with O-OFF-C switch several times. 8. Physically stall doors again in closing direction and re-check door closing force with pressure gauge. ADJUST NUDGE SPEED 1. Simulate a nudge signal by placing a jumper on terminal strip TB-1 between L1A and DO4. 2. Set the TEST-RUN switch to TEST position. 3. Set O-OFF-C switch to C position. Doors should close at nudge speed. 4. Turn the N potentiometer clockwise to desired nudging speed. 5. Remove jumper between L1A and DO4 before returning the TEST-RUN switch to RUN. F615-010 (2/97) When all adjustments are complete, place O-OFF-C switch in OFF position, and TEST-RUN switch in RUN position. Replace door operator cover. A604-SI7 (2/97) If door closing force CANNOT be kept under 30 pounds, contact Moline Accessories Company. A604-021 (2/97) 16 PAA8-606 (4/98)

Door Operator Conversion SET MICROSWITCH CAMS PM/SSC door operator microswitch cams determine where changes in door speed occur. Factory settings are approximate. Set microswitch cams, if necessary, per individual job requirements. CL CAM actuates CL microswitch when doors are in their desired fully closed position. PL Initial opening CAM drops microswitch when car door clutch has just engaged both hoistway door rollers, but should not drop microswitch if door interlock hangs up. OSDL CAM drops OSDL microswitch when doors are approximately half open. CSDL CAM drops CSDL microswitch when doors are approximately 4 inches [10.2 mm] from their fully closed position. OL DSD CAM actuates OL microswitch when doors are in fully open position. (optional) CAM actuates DSD microswitch when doors are approximately 4 to 6 inches [10.2 to 15.2 mm] from fully closed position. CAM can also be set for other customer requirements. F615-009 (4/98) Door in closed position Door in open position 17

Replacement Parts DOOR OPERATOR CONVERSION KIT: Type M to PM/SSC or HPM/SSC with Board 1Ø4 Type M to PM/SSC or HPM/SSC 18 PAA8-606 (4/98)

Door Operator Conversion Replacement Parts DOOR OPERATOR CONVERSION KIT: Type M to PM/SSC with Board 1Ø4 KEY MKOPART PARTNAME REMARK 1 P-22267-001 Kit, door conversion to solid state RH, To convert type M to PMSSC; Includes motor, door control w/board 104, and cover P-22267-002 Kit, door conversion to solid state LH, To convert type M to PMSSC; Includes motor, door control w/board 104, and cover NS P-22337-001 Kit, door conversion to solid state RH, To convert type M to HPMSSC; Includes motor, door control w/board 104, and cover NS P-22337-002 Kit, door conversion to solid state LH, to convert type M to HPMSSC; Includes motor, door control w/board 104, and cover 2 19502-031 Sheave, single 1.7 in. pitch for reduction 3 101849 Motor, permanent magnet 1/6 HP, 1140 RPM, 24 VDC 4 49744 Cover, bottom PM/SSC 5 P-22248 Door control board 104 PM/SCC standard door control 6 P-24783 PC board, door operator PM/SSC board 104 7 P-24186 Cover, door operator PM/SCC NS 46208 Transformer 32V 250VA, located on bottom of P-22248 door control NS 46217-020 Rectifier, bridge 25A 200V, located on bottom of P-22248 door control NS 46218 Capacitor, electrolytic Used with Kit P-22267-***, 4500 uf, 50 WV, located on bottom of P-22248 door control NS 49732 Capacitor, electrolytic Used with Kit P-22337-***, 41000 uf, 50 WV for high performance power supply, located on bottom of P-22248 door control NS 90527-022 Cable 13 connector, 18 AWG, MLX/FRK The following kits are also available to convert WM door operators to WMHPMSSC door operators. NS P-22268-001 Kit, door conversion to solid state RH, to convert type WM to WMHPMSSC; Includes motor, door control w/board 104, and cover NS P-22268-002 Kit, door conversion to solid state LH, to convert type WM to WMHPMSSC; Includes motor, door control w/board 104, and cover NS = Not shown 19

Type M to PM/SSC or HPM/SSC MOLINE ACCESSORIES COMPANY 107 18th Street; Moline, IL 61265 Phone: 309-762-6888 FAX: 309-762-7475 20 PAA8-606 (4/98)