VECTOR INVERTER -INSTRUCTION MANUAL- ADDITIONAL OPEN COLLECTOR OUTPUT / PLG PULSE DIVISION OUTPUT FR-V5AY

Similar documents
This section is specifically about safety matters

Filterpack FR-BFP2-(H)0.4K to (H)15K

TRANSISTORIZED INVERTER INSTRUCTION MANUAL HIGH-DUTY BRAKE RESISTOR FR-ABR(H)

MITSUBISHI LARGE CAPACITY INVERTER MELTRAC-REC(MT-REC) -INSTRUCTION MANUAL- 12 Pulse Bridge Converter

This section is specifically about safety matters

FR-A7NP E kit cover SC

FR-A7AZ INSTRUCTION MANUAL

FR-BU2-1.5K to 55K FR-BU2-H7.5K to H280K

Heatsink Protrusion Attachment. <FR-E7CN01 to 06>

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

FR-BU2-1.5K to 55K FR-BU2-H7.5K to H280K

I. Safety precautions

EVS RP6020. Instruction Manual

RP Instruction Manual

FR-CV-7.5K to 30K(-AT) FR-CV-37K, 55K FR-CV-H7.5K to H30K(-AT) FR-CV-H37K, H55K FR-CVL-7.5K to 55K FR-CVL-H7.5K to H55K FR-CV TRANSISTORIZED INVERTER

Installation and Operating Instructions. Solar System Controller ISC3030

SUPPLEMENTAL RESTRAINT SYSTEM (SRS)

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Installation and Operating Instructions. Solar System Controller ISC3020

Technical Documentation

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Galaxy Receiving and Unpacking 09/

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

5.1 Errors (Alarms) Error (alarm) definitions PROTECTIVE FUNCTIONS. (1) Major faults

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

ECONOMISER SERIES E2T USER MANUAL

Installation and Operation Manual

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

User Manual Solar Charge Controller 3KW

M Series External Battery Frame. User Guide

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

Differential Pressure Transmitter

Operation Manual for Mag650 Three-Axis Magnetic Field Sensor

Instruction Manual LAMI CORPORATION INC.

FX2N-2LC SPECIAL FUNCTION BLOCK

USER'S MANUAL MODEL DPD60001 MICROSTEP DRIVER PACK

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

SDRIVE. dynamic braking unit Getting Started Manual. DB Series DYNAMIC BRAKING

Extended Panel Operation Manual RKP001Z-0

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Service Manual Model L1000 Smart Lift

Solar Hybrid Inverter SP Efecto Series

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

User Manual 1KVA-5KVA INVERTER / CHARGER

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

DVFP Series Variable Frequency Drive - Product Manual. pg. 1

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L?

User Manual. SV-DBH Series. LG Dynamic Braking Units. LG Industrial Systems

BEFORE USING THE PRODUCT

B297SB-01-1K40. AnyWireASLINK System Product Guide. ASLINKSENSOR [Photo Interrupter type] -B297SB011K40 1/7- [Function] [Notes on Safety]

Utilization of Electric Power Laboratory 3 rd Year G2: Testing & Characteristic of MCCB Used in Commercial and Industrial Applications

Service Manual. Model L500 and L600 Smart Lift. WARNING: Cancer and Reproductive Harm - Form #1-144 Rev.

Service Manual Model S800 Smart Stand


Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Galaxy VM. Battery Breaker Box Installation 09/

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1.5KVA-3KVA INVERTER / CHARGER

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

Service Manual Model S400 and S500 Smart Stand

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

GRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/

STR3. Step Motor Drive. User Manual

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

DRB-1 Series Instruction Manual

High Frequency SineWave Guardian TM

230VAC Power Inverter 400W Owner s Manual

KD1E Range Potential Indicators

Compact Sine Inverter

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

DIAGNOSTIC TOOL BATTERY

Cordless Rechargeable Saw Instructions for Use

Solar Hybrid Inverter SP Efecto Series

SINAMICS. SINAMICS G130 Braking Module / braking resistor. Safety information 1. General. Mechanical installation. Connection 4

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Appendix: Safety and application notes for... 15

Safety Working with LV Drives

POWER REGULATOR LD -40PSU

Installing an Auxiliary Pressure Control Module

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Solar Hybrid Inverter SP Brilliant Series

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

SERVICE MANUAL BAS-311H. Please read this manual before making any adjustments. DIRECT DRIVE PROGRAMMABLE ELECTRONIC PATTERN SEWER

Power Inverter 400 MW Owner s Manual

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

HOYMILES MICRO-IVERTER MI-250

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Transcription:

VECTOR INVERTER -INSTRUCTION MANUAL- ADDITIONAL OPEN COLLECTOR OUTPUT / PLG PULSE DIVISION OUTPUT FR-V5AY

Thank you for choosing the Mitsubishi vector inverter option unit. This instruction manual gives handling information and precautions for use of this equipment. Incorrect handling might cause an unexpected fault. Before using the equipment, please read this manual carefully to use the equipment to its optimum. Please forward this manual to the end user. 1. Electric Shock Prevention This section is specifically about safety matters Do not attempt to install, operate, maintain or inspect this product until you have read through this instruction manual and appended documents carefully and can use the equipment correctly. Do not use this product until you have a full knowledge of the equipment, safety information and instructions. In this instruction manual, the safety instruction levels are classified into "WARNING" and "". Assumes that incorrect handling may cause hazardous conditions, resulting in WARNING death or severe injury. Assumes that incorrect handling may cause hazardous conditions, resulting in medium or slight injury, or may cause physical damage only. Note that the level may lead to a serious consequence according to conditions. Please follow the instructions of both levels because they are important to personnel safety. SAFETY INSTRUCTIONS WARNING! While power is on or when the inverter is running, do not open the front cover. You may get an electric shock.! Do not run the inverter with the front cover removed. Otherwise, you may access the exposed high-voltage terminals and charging part and get an electric shock.! If power is off, do not remove the front cover except for wiring or periodic inspection. You may access the charged inverter circuits and get an electric shock.! Before starting wiring or inspection, switch power off, wait for more than 10 minutes, and check for no residual voltage with a tester or the like. A-1

2. Injury Prevention 3. Additional instructions Also note the following points to prevent an accidental failure, injury, electric shock, etc.: (1) Transportation and mounting (2) Test operation and adjustment WARNING! Any person who is involved in the wiring or inspection of this equipment should be fully competent to do the work.! Always install the option unit before wiring. Otherwise, you may get an electric shock or be injured.! Handle this option unit with dry hands to prevent an electric shock.! Do not subject the cables to scratches, excessive stress, heavy loads or pinching. Otherwise, you may get an electric shock.! Apply only the voltage specified in the instruction manual to each terminal to prevent burst, damage, etc.! Ensure that the cables are connected to the correct terminals. Otherwise, burst, damage, etc. may occur.! Always make sure that polarity is correct to prevent burst, damage, etc.! While power is on or for some time after power-off, do not touch the inverter as it is hot and you may get burnt.! Do not install or operate the option unit if it is damaged or has parts missing.! Do not stand or rest heavy objects on the product.! Check that the mounting orientation is correct.! Prevent screws, metal fragments or other conductive bodies or oil or other flammable substance from entering the inverter.! Before starting operation, confirm and adjust the parameters. A failure to do so may cause some machines to make unexpected motions. A-2

(3) Usage! Do not modify the equipment. WARNING (4) Maintenance, inspection and parts replacement! When parameter clear or all parameter clear is performed, each parameter returns to the factory setting. Re-set the required parameters before starting operation.! For prevention of damage due to static electricity, touch nearby metal before touching this product to eliminate static electricity from your body.! Do not test the equipment with a megger (measure insulation resistance). (5) Disposal! Treat as industrial waste. (6) General instruction All illustrations given in this manual may have been drawn with covers or safety guards removed to provide indepth description. Before starting operation of the product, always return the covers and guards into original positions as specified and operate the equipment in accordance with the manual. A-3

CONTENTS 1.PRE-OPERATION INSTRUCTIONS 1 1.1 Unpacking and Product Confirmation...1 1.2 Packing Confirmation...1 1.3 Structure...1 2.INSTALLATION 2 2.1 Pre-Installation Instructions...2 2.2 Installation Procedure...2 2.3 Wiring...4 3.ADDITIONAL OPEN COLLECTOR OUTPUT 5 3.1 Overview...5 3.2 Explanation of the Terminals...5 3.3 Related Parameters...6 3.4 Setting...6 4.PLG PULSE DIVISION OUTPUT 7 4.1 Block Diagram...7 4.2 Explanation of the Terminals...9 4.3 Related Parameters...10

1.PRE-OPERATION INSTRUCTIONS 1.1 Unpacking and Product Confirmation Take the option unit out of the package, check the unit name, and confirm that the product is as you ordered and intact. This product is an option unit designed for exclusive use in the Mitsubishi FR-V500 series vector inverter. Functions available differ, before using it, always make the following checks. 1.2 Packing Confirmation Make sure that the package includes the following " Instruction manual...1 " Mounting screws M3 10...2 1.3 Structure ounting hole Front view Mounting holes Rear view Mounting hole Terminal block screw size M3 FPA FPAR FPB FPZR FPA2 FPB2 FPZ2 DO11 DO13 SE3 FPBR FPZ DO12 Terminal symbol FR-V5AY Option fixing holes Connector 1

2.INSTALLATION 2.1 Pre-Installation Instructions Make sure that the input power of the inverter is off. 2.2 Installation Procedure With input power on, do not install or remove the option unit. Otherwise, the inverter and option unit may be damaged. (1) Securely insert the connector of the option unit far into the connector of the inverter. At this time, fit the option fixing holes snugly. Also be sure to fit the unit into the option fixing hook. (2) Securely fix the option unit to the inverter on both sides with the accessory mounting screws. If the screw holes do not match, the connector may not have been plugged snugly. Check for loose plugging. 2

INSTALLATION Option unit Accessory screw (2 pcs.) Option side connector Inverter (without cover) Slot 1 Inverter side connector Slot 2 Option fixing hook Slot 3 The slots 1, 2, and 3 are provided with an option fixing hook. 1. Only one type of option per inverter may be used. When two or more options are mounted, priority is in order of slots 1, 2 and 3, the options having lower priority are inoperative. 2. When the inverter cannot recognize that the option is Mounting Position Error Display mounted, it displays the option error. The errors shown Slot 1 E.OP1 differ according to the mounting slots 1, 2, 3. Slot 2 E.OP2 Slot 3 E.OP3 3

INSTALLATION 2.3 Wiring Route the wires so that they do not take up a large space in the control circuit terminal block of the option unit. During wiring, do not leave wire off-cuts in the inverter. They may cause a fault, failure or malfunction. Use the space on the left side of the Control circuit terminal unit to route the wires. Cable routing REMARKS The wires with large gaze may not be connected to the terminal block. When connected in parallel, all wires may not fit in the wiring space due to the increased number of wires. In such cases, perform wiring by using a junction terminal block. When installing the inverter front cover, the cables to the inverter's control circuit terminals and option terminals should be routed properly in the wiring space to prevent them from being caught between the inverter and its cover. 4

3.ADDITIONAL OPEN COLLECTOR OUTPUT 3.1 Overview Three terminal output points can be added by making the assignment of the output terminals using Pr. 410 to Pr. 412 (output terminal function selection). At this time, since four more points can be chosen with Pr. 190 to Pr. 192 and Pr. 195 (output terminal function selection) of the inverter, a total of seven output terminals are available. 3.2 Explanation of the Terminals Terminal Symbol DO11 DO12 DO13 SE3 Terminal Name Rated Current, etc. Description Multi-function output terminal Open collector output common Open collector output Permissible load 24VDC, max. 100mA Set function assignment in Pr. 410 to Pr. 412 (output terminal function selection). Common terminal for the DO11, DO12 and DO13 terminals. Isolated from the common of the control circuit. Do not earth this terminal. 5

ADDITIONAL OPEN COLLECTOR OUTPUT 3.3 Related Parameters Parameter Number 3.4 Setting Name Factory Setting Setting Range Minimum Setting Increments 410 DO11 terminal function selection 9999 0 to 199, 9999 1 411 DO12 terminal function selection 9999 0 to 199, 9999 1 412 DO13 terminal function selection 9999 0 to 199, 9999 1 REMAKS For Pr.410 to Pr.412, write is disabled during operation even when 2 is set in Pr.77. When changing the parameter setting, stop the operation. The functions of the DO11, DO12 and DO13 output terminals can be assigned individually. The settings of Pr. 410 to Pr. 412 (output terminal function selection) are the same as those of Pr. 190 to Pr. 192 and Pr. 195 (output terminal function selection). For details of Pr. 190 to Pr. 192 and Pr. 195, refer to the Inverter Instruction Manual (basic). 6

4.PLG PULSE DIVISION OUTPUT The PLG pulse input connected to the inverter can be divided and output from the terminals of the option. 4.1 Block Diagram Motor end PLG A, B, Z phases Inverter FR-V5AY A phase B phase Division ratio 1 Pr. 413 setting FPA2 (A phase) FPB2 (B phase) FPZ2 (Z phase) PLG pulse output (open collector) (Cautoin) Z phase A phase B phase Division ratio 1 Pr. 413 setting Z phase FPA (A phase) FPAR FPB (B phase) FPBR FPZ (Z phase) FPZR PLG pulse output (differential line driver) 7

PLG PULSE DIVISION OUTPUT For open collector output, the signal becomes unstable when the input resistance of the connected device is high, resulting in miss detection of the signal. This may be improved by connecting the pullup resistance. Select the resistance value of the pull-up resistance considering the input current of the connected device so that the open collector output current does not exceed the permissible output load current. Supply - + Inverter Pull-up resistance FR-V5AY FPA2/FPB2/FPZ2 SD Connected device 8

4.2 Explanation of the Terminals PLG PULSE DIVISION OUTPUT Output the A-phase, B-phase and Z-phase (origin and mark pulse) signals from the PLG. The A-phase and B-phase signals can be divided by the ratio (1/n) and output. n = 1 to 32767 (integer). Set the ratio in Pr. 413 "PLG pulse division ratio". This PLG pulse division output function uses the following terminals. Open collector Terminal Symbol Differential line driver Terminal Symbol Terminal Name Rated Current, etc. Remarks FPA2 A-phase output terminal Open collector output FPB2 B-phase output terminal Permissible load FPZ2 Z-phase output terminal 24VDC, max. 50mA FPA FPAR FPB FPBR FPZ The common terminal is the SD terminal of the inverter. Terminal Name Rated Current, etc. Remarks Differential A-phase output terminal Differential A-phase inverse signal output terminal Differential B-phase output terminal Differential B-phase inverse signal output terminal Differential Z-phase output terminal Differential output Permissible load 0.1A FPZR Differential Z-phase inverse signal output terminal * The division ratio setting is same for open collector output and differential line driver output. - 9

PLG PULSE DIVISION OUTPUT 4.3 Related Parameters Parameter Number Name Factory Setting Setting Range Minimum Setting Increments 413 PLG pulse output division ratio 1 1 to 32767 1 (1) Pr. 413 "PLG pulse output division ratio" The signals of motor end PLG pulses can be divided and output at the division ratio set in Pr. 413. Used to lower the response level of the machine to which pulses are input, for example. (2) Division waveforms according to the division ratio Both the ON and OFF widths are multiplied by the set value. (50% duty) Pulse waveform when Pr. 413 = 2 (ON/OFF example at input of 1000 pulses) ivision ratio 1/1 A phase B phase (1000 pulses) ivision ratio 1/2 A phase B phase 2 divisions (500 pulses) REMARKS Forward/reverse rotation control is exercised according to the phase difference between the A and B phases. When the A phase leads the B phase by 90 : Forward rotation When the A phase lags the B phase by 90 : Reverse rotation 10

REVISIONS *The manual number is given on the bottom left of the back cover. Print Date *Manual Number Revision Oct., 2001 IB(NA)-0600085-A First edition