DEEP SEA ELECTRONICS PLC DSE9000 SERIES BATTERY CHARGER OPERATOR MANUAL

Similar documents
DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual

DSEULTRA DSE6000 Quick Start Guide Document Number

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DSE3210 CONTROLLER OPERATORS MANUAL

DEEP SEA ELECTRONICS PLC DSE7110 MKII & DSE7120 MKII Operator Manual

DEEP SEA ELECTRONICS PLC DSE6010 MKII & DSE6020 MKII Operator Manual

PSU EN54-4 Power Supplies

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DSE6610 & DSE6620 Operator Manual

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

DEEP SEA ELECTRONICS PLC DSEL401 MKII Operator Manual

DEEP SEA ELECTRONICS PLC DSEE400 Operator Manual

DEEP SEA ELECTRONICS PLC

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

DEEP SEA ELECTRONICS PLC

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

DEEP SEA ELECTRONICS PLC

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Elmdene International Ltd

DEEP SEA ELECTRONICS PLC DSEE100 Operator Manual

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

K25000 & KD25000 Series

DEEP SEA ELECTRONICS

Deep Sea Electronics Plc

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

DEEP SEA ELECTRONICS DSE7110 MKII / DSE7120 MKII Configuration Suite PC Software Manual

User Manual. Solar Charge Controller 3KW

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Phoenix Inverter

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

INTRODUCTION MARKET SECTORS CUSTOMER SERVICE CCL OFFERS YOU. Switchmode Technology A highly efficient, lightweight

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DEEP SEA ELECTRONICS

SBC / 2140 / Stage Battery Charger User Manual

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Technical Data Sheets

Features. Description. Table of Contents

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

User Manual Solar Charge Controller 3KW

Liebert PowerSure PSI UPS

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Technical Data Sheets

REVISED ATM72 Auto Transfer Module

Sentry Battery Charger. Installation and Operations Manual Section 75

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

CBI All in One DC UPS Power Solutions

Guardian Battery Charger Series. Installation and Operations Manual Section 75

80V 300Ah Lithium-ion Battery Pack Data Sheet

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

Sola/Hevi-Duty S3K Series Mini-Tower UPS

SECTION DC POWER SUPPLY/BATTERY CHARGER

DEEP SEA ELECTRONICS

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

DC POWER SUPPLY SYSTEMS

TECHNICAL DATA SHEET KVA UPS Systemss

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

SDM72 Start on Demand Modules

Maximum Input Current Vin=18V, 100% Load A Vin=24V ma No-Load Input Current

DEEP SEA ELECTRONICS

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

PowerValue 11/31 T kva

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

Industrial Power Supplies

Technical Data Sheets

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Automatic DC Power Supply/Battery Charger

All In one uninterruptible power supply solutions

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

DC POWER SUPPLY ALIMENTATION C.C.

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

Technical Data Sheets

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

Deep Sea Electronics Plc

Installation Instructions

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Technical Data Sheets

InteliCharger V 20A Intelligent Automatic Battery Charger

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

B70SR12424A/B/C/D 12V Output DC/DC Converter, Box Type Package

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

EC400 Power Control System

Transcription:

DEEP SEA ELECTRONICS PLC DSE9000 SERIES BATTERY CHARGER OPERATOR MANUAL Document Number: 057-085 Author: Ashley Senior DSE9000 Series Battery Charger Operator Manual ISSUE 13

DSE9000 Series Battery Charger Operator Manual Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723 890099 Sales Fax: +44 (0) 1723 893303 E-mail: sales@deepseaplc.com Website: www.deepseaplc.com DSE9000 Series Battery Charger Operator Manual Deep Sea Electronics Plc All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder except in accordance with the provisions of the Copyright, Designs and Patents Act 1988. Applications for the copyright holder s written permission to reproduce any part of this publication should be addressed to Deep Sea Electronics Plc at the address above. Any reference to trademarked product names used within this publication is owned by their respective companies. Deep Sea Electronics Plc reserves the right to change the contents of this document without prior notice. Amendments since last publication Issue. No. Comments 1 Added Efficiency curve of 2A charger 2 Updated specs table of 3.7A charger 3 Added 5A DSE9255 charger and 9250-002 277V input charger 7 Added DSE9155 30V 2A charger 8 Added 10A charger 8.1 Added Indication (LED) for 10A chargers 8.2 Added detail regarding -002- chargers asnd cabinet/industrial chargers 9 Added 9400 series 9.1 Corrected specs for 9140 10 Removed all DSE9400 series chargers, added DSE9470 11 Added new DSE9400 series Chargers 12 Changes to add DSE9150 12V 3A Updated DSE9470 and DSE9480 to -003 (MKII) and added DSE9472MKII and 13 DSE9481 MKII Typeface : The typeface used in this document is Arial. Care should be taken not to mistake the upper case letter I with the numeral 1. The numeral 1 has a top serif to avoid this confusion. 2

DSE9000 Series Battery Charger Operator Manual 1 BIBLIOGRAPHY... 5 1.1 INSTALLATION INSTRUCTIONS... 5 1.2 MANUALS... 5 3 SPECIFICATIONS... 7 3.1 PART NUMBERING... 7 3.1.1 DSE9100 CHASSIS MOUNT BATTERY CHARGERS... 7 3.1.2 DSE9200 CHASSIS MOUNT BATTERY CHARGERS... 8 3.1.3 DSE9400 MKII SERIES CHASSIS MOUNT BATTERY CHARGERS... 9 3.1.4 DSE907 INDUSTRIAL / DSE908 CABINET MOUNTED BATTERY CHARGERS... 10 3.2 COMMON ELECTRICAL SPECIFICATIONS... 11 3.3 COMMUNICATION PORT USAGE... 12 3.3.1 USB CONNECTION... 12 3.3.2 RS485... 13 3.5 OUTPUT SPECIFICATIONS... 15 3.5.1 DSE9130 12V 5A... 15 3.5.2 DSE9140 12V 10A... 16 3.5.3 DSE9150 12V 2A... 17 3.5.4 DSE9150 12V 3A... 18 3.5.5 DSE9155 30V 2A... 19 3.5.6 DSE9250 24V 3.7A... 20 3.5.7 DSE9255 24V 5A... 21 3.5.8 DSE9260 24V 10A... 22 3.5.9 DSE9470 (MKII) 24V/12V 10A... 23 3.5.10 DSE9472 (MKII) 24V/12V 5A... 25 3.5.11 DSE9480 (MKII) 12V 10A... 26 3.5.12 DSE9481 (MKII) 12V 5A... 28 3.6 DIMENSIONS AND MOUNTING... 29 3.6.1 DSE907 12V 10A INDUSTRIAL BATTERY CHARGER... 29 3.6.2 DSE908 12V & 24V 10A CABINET MOUNTED BATTERY CHARGER... 30 3.6.3 DSE9130 12V 5A... 31 3.6.4 DSE9150 12V 2A... 32 3.6.5 DSE9150 12V 3A... 33 3.6.6 DSE9140 12V 10A... 34 3.6.7 DSE9155 30V 2A... 35 3.6.8 DSE9250 24V 3.7A... 36 3.6.9 DSE9255 24V 5A... 37 3.6.10 DSE9260 24V 10A... 38 3.6.11 DSE9470 (MKII) 24V/12V 10A... 39 3.6.12 DSE9472 (MKII) 24V/12V 5A... 40 3.6.13 DSE9480 (MKII) 12V/24V 10A... 41 3.6.14 DSE9481 (MKII) 12V/24V 5A... 42 3.7 APPLICABLE STANDARDS... 43 4 INSTALLATION... 44 4.1 BATTERY SUITABILITY... 44 4.2 USER CONNECTIONS... 44 4.2.1 DSE9130, DSE9140, DSE9250, DSE9255 & DSE9260... 45 4.2.2 DSE9150... 45 4.2.3 DSE9155... 46 4.2.4 DSE9470 MKII, DSE9472 MKII, DSE9480 MKII, DSE9481 MKII... 47 4.3 TYPICAL WIRING DIAGRAM... 49 4.3.1 DSE9150... 49 4.3.2 DSE9155 & DSE9200 SERIES... 50 4.3.3 DSE9470 MKII, DSE9472 MKII, DSE9480 MKII, DSE9481 MKII... 51 5 INDICATIONS... 52 5.1 DSE907... 52 5.2 DSE908... 52 5.3 DSE9130, DSE9150, DSE9155, DSE9250 & DSE9255... 53 5.4 DSE9140 & DSE9260... 54 3

DSE9000 Series Battery Charger Operator Manual 5.5 DSE9470 MKII, DSE9472 MKII, DSE9480 MKII, DSE9481 MKII... 55 5.5.1 STATUS... 55 5.5.2 CHARGE MODE... 55 5.5.3 FAULT CONDITIONS... 55 6 OPERATION... 56 6.1 OPERATION OF DSE9100 SERIES / DSE9200 SERIES... 56 6.1.1 PROTECTION... 56 6.1.2 PSU MODE... 56 6.1.3 CHARGE MODE... 56 6.1.4 BOOST MODE... 57 6.2 OPERATION OF DSE9400 MKII SERIES... 58 6.2.1 PROTECTION... 58 6.2.2 DIGITAL INPUT... 59 6.2.3 VOLTAGE ADJUSTMENT POTENTIOMETER... 59 6.2.4 PSU MODE... 59 6.2.5 CHARGE MODE... 60 6.2.6 TEMPERATURE COMPENSATION... 61 7 FAULT DIAGNOSIS... 62 8 MAINTENANCE, SPARES, REPAIR AND SERVICING... 63 9 WARRANTY... 63 10 DISPOSAL... 63 10.1 WEEE (WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT)... 63 10.2 ROHS (RESTRICTION OF HAZARDOUS SUBSTANCES)... 63 4

Bibliography 1 BIBLIOGRAPHY This document refers to and is referred to by the following DSE publications which can be obtained from the DSE website www.deepseaplc.com 1.1 INSTALLATION INSTRUCTIONS Installation instructions are supplied with the product in the box and are intended as a quick start guide only. DSE PART DESCRIPTION 053-049 DSE9200 / DSE9400 Series Battery Charger Installation Instructions 053-123 DSE9150 Battery Charger Installation Instructions 1.2 MANUALS DSE PART DESCRIPTION 057-159 DSE9400 Series Battery Charger Configuration Suite Manual 5

Introduction 2 INTRODUCTION NOTE: This document DOES NOT contain details of the obsolete DSE9210 and DSE9240 battery chargers. For further details of these units, please contact Deep Sea Electronics. This document details the installation requirements of the DSE9000 series range of battery chargers. The manual forms part of the product and should be kept for the entire life of the product. If the product is passed or supplied to another party, ensure that this document is passed to them for reference purposes. This is not a controlled document. You will not be automatically informed of updates. Any future updates of this document will be added to the DSE website at www.deepseaplc.com. The DSE9000 series modules are intended for mounting within a customer enclosure or panel (DIN rail mounting or fastened by screws/bolts). DSE also supply some of the battery chargers as completed units, factory mounted into enclosures for wall or floor mounting. The DSE9000 series chargers fulfill the most common functions required of a charger in the generating set industry. Combining protected outputs, intelligent charging and power supply operation with a robust enclosure. 6

3 SPECIFICATIONS 3.1 PART NUMBERING 3.1.1 DSE9100 CHASSIS MOUNT BATTERY CHARGERS 9130-001 - 00 Product type DSE9130 12V 5A 9130 DSE9140 12V 10A 9140 DSE9150 12V 2A 9150 DSE9150 12V 3A 9150 DSE9155 30V 2A 9155 For lead acid batteries 12V charger set to 13.7V 24V charger set to 27.4V For 9 or 18 cell NICAD batteries* 12V charger set to 13.0V 24V charger set to 26.0V For 10 or 20 cell NICAD batteries* 12V charger set to 14.5V 24V charger set to 29.0V For other battery types* Specify required float voltage on ordering** Variant 00 01 02 03 Hardware revisions First version hardware 001 NOTE: For descriptions of other Hardware Revisions, please contact support@deepseaplc.com NOTE: The DSE9150 12V 2A is now obsolete, replaced with DSE9150 12V 3A. NOTE: The DSE9150 12V 3A only available in Variant -00 (13.7V for lead acid batteries) NOTE: For variant 03 (For other battery types), the float voltage can be adjusted between 12.5V and 15V for DSE9130 12V 5A chargers (25V - 30V for DSE9250 24V 3.7A chargers). This change must be made at the DSE factory. Ensure the correct variant (and float voltage if applicable) is specified on ordering. Consult your battery manufacturer for further details of required float voltage. 7

3.1.2 DSE9200 CHASSIS MOUNT BATTERY CHARGERS 9130-001 - 00 Product type DSE9250 24V 3.7A 9250 DSE9255 24V 5A 9255 DSE9260 24V 10A 9260 For lead acid batteries 12V charger set to 13.7V 24V charger set to 27.4V For 9 or 18 cell NICAD batteries* 12V charger set to 13.0V 24V charger set to 26.0V For 10 or 20 cell NICAD batteries* 12V charger set to 14.5V 24V charger set to 29.0V For other battery types* Specify required float voltage on ordering** Variant 00 01 02 03 Hardware revisions First version hardware 001 NOTE: For descriptions of other Hardware Revisions, please contact support@deepseaplc.com NOTE: - The DSE9250 battery charger is now obsolete, details provided for information only. NOTE: For variant 03 (For other battery types), the float voltage can be adjusted between 12.5V and 15V for DSE9130 12V 5A chargers (25V - 30V for DSE9250 24V 3.7A chargers). This change must be made at the DSE factory. Ensure the correct variant (and float voltage if applicable) is specified on ordering. Consult your battery manufacturer for further details of required float voltage. 8

3.1.3 DSE9400 MKII SERIES CHASSIS MOUNT BATTERY CHARGERS 9470-001 - 00 Product type DSE9470 12/24V 10A 9470 DSE9472 24V/12V 5A 9472 DSE9480 24V/12V 10A 9480 DSE9481 24V/12V 5A 9481 Variant Standard 00 Hardware revisions First version hardware 001 NOTE: For descriptions of other Hardware Revisions, please contact support@deepseaplc.com NOTE: For hardware versions 003 and above, voltage and current levels can be user configured via DSE Configuration Suite PC Software. Part number 9470-001-00 is fixed at 24V 10A. Part number 9480-001-00 is fixed at 12V 10A. NOTE: DSE9400 series battery chargers are customer configurable via the DSE Configuration Suite PC Software. For further details, you are referred to DSE Publication: 057-159 DSE9400 Series Battery Charger Configuration Suite Manual. 9

3.1.4 DSE907 INDUSTRIAL / DSE908 CABINET MOUNTED BATTERY CHARGERS NOTE: The DSE907 / DSE908 Industrial / Cabinet Mounted Battery Chargers are now obsolete, replaced by DSE9460 / DSE9461 Enclosed Battery Chargers. See the preceeding page for details of part numbering of chassis mounted battery chargers. Industrial / Cabinet mounted battery chargers are 9000 series battery chargers factory fitted into wall mounted enclosures. For details see the section entitled Dimensions and Mounting elsewhere in this document. 0907-002-02 INDUSTRIAL BATTERY CHARGER 12V 5A 220-250V 0908-001-11 CABINET MOUNTED BATTERY CHARGER 12V 10A 0908-001-21 CABINET MOUNTED BATTERY CHARGER 24V 10A 0907-001 - 00 Variant Product type Hardware revisions When ordering Industrial / Cabinet mounted battery chargers, ensure you specify the type of batteries that are to be charged. If you do not specify this, the chargers will be preset to charge Lead Acid type batteries. 10

3.2 COMMON ELECTRICAL SPECIFICATIONS Parameter Min Nominal Max AC Input Voltage (V) DSE9130 12V 5A DSE9150 12V 2A DSE9150 12V 3A DSE9140 12V 10A DSE9155 30V 2A DSE9250 24V 3.7A (9250-001-xx) DSE9250 24V 3.7A (9250-002-xx) DSE9255 24V 5A DSE9260 24V 10A DSE9470 24V/12V 10A DSE9472 24V 5A DSE9480 12V/24V 10A DSE9481 12V 5A 90V 90V 90V 90V 85V 90V 90V 90V 90V 95V 95V 95V 95V 110V-277V 110V-240V 110V-240V 110V-240V 110V-240V 110V-240V 110V-277V 110V-277V 110V-277V 110V-277V 110V-277V 110V-277V 110V-277V 304V 250V 265V 277V 265V 265V 305V 305V 305V 305V 305V 305V 305V Operating Temperature DSE9100 Series DSE9200 Series DSE9400 Series -30 C -30 C -30 C 55 C 55 C 85 C with de-ratings Input Frequency (Hz) 48Hz 64Hz DSE9100 Series 1% Vo Output Ripple and DSE9200 Series 2% Vo Noise DSE9400 Series 1% Vo Load Regulation DSE9100 Series DSE9200 Series DSE9400 Series Line Regulation Output Voltage Overshoot % Transient Response Peak Deviation (mv) (at 50% to 100% load step) Warm Up Voltage (V) DSE9100 Series Output Voltage DSE9200 Series Rise Time (ms) DSE9400 Series Short Circuit Protection Switching Frequency (khz) 9130-001-xx (replaced with 9130-002-xx) 9250-001-xx (replaced with 9250-002-xx) 1% Vo 2% Vo 1% Vo <0.01% Vo <5%Vo <4% Vo <1% Vo <100ms <100ms <200ms Hiccup 100kHz 100kHz 9130-002-xx 9250-002-xx 94xx-xxx-xx 67kHz 67kHz 67kHz Efficiency % (See section entitled output specifications elsewhere in this manual) Temperature Sensor Input All other chargers DSE9100 Series DSE9200 Series 100kHz >80% DSE9400 Series >85% DSE9400 Series PT1000 NOTE: Check the DSE9400 Series de-rating curves which can be found else where in this manual for more information. 11

3.3 COMMUNICATION PORT USAGE Communication USB Port (DSE9400 series only) RS485 Serial Port (DSE9400 series only) Specification USB2.0 Device for connection to PC running DSE Configuration Suite Max distance 6m (20 feet) Isolated Data connection 2 wire + common Half Duplex Data direction control for Transmit (by s/w protocol) Max Baud Rate 19200 External termination required (120Ω) Max common mode offset 70V (on board protection transorb) Max distance 1.2km (¾ mile) 3.3.1 USB CONNECTION The USB port is provided to give a simple means of connection between a PC and the DSE9400 series battery charger. Using the DSE Configuration Suite Software, the operator is then configure and monitor the state of the battery charger. To connect a DSE9400 series battery charger to a PC by USB, the following items are required: DSE9400 series battery charger DSE Configuration Suite Software (Supplied on configuration suite software CD or available from www.deepseaplc.com). USB cable Type A to Type B. (This is the same cable as often used between a PC and a USB printer) DSE can supply this cable if required : PC Configuration interface lead (USB type A type B) DSE Part No 016-125 NOTE: - Refer to DSE9400 Series Battery Charger PC Software Configuration Manual for further details on configuring and monitoring. 12

3.3.2 RS485 The RS485 port on the DSE9400 series battery chargers has two uses. 1) Supporting the DSE2541 remote battery charger display module (MKII only) 2) Support the Modbus RTU protocol for connection to a Modbus RTU Master device. 3.3.2.1 DSE2541 REMOTE BATTERY CHARGER DISPLAY MODULE DSE2541 remote battery charger display modules connects to the DSE9400 MKII Series battery charger RS485 terminals. This provides battery charger operating status, alarm indication, instrumentation and control over the DSE9400 MKII Series battery charger. For further information please contact sales@deepseaplc.com. 3.3.2.2 MODBUS RTU RS485 is used for point-to-point cable connection of more than one device (maximum 32 devices) and allows for connection to PCs, PLCs and Building Management Systems (to name just a few devices). Using the DSE Configuration Suite PC Software, Configurable Gencomm is used to map instrumentation to modbus registers. One advantage of the RS485 interface is the large distance specification (1.2km) when using Belden 9841 (or equivalent) cable. This allows for a large distance between the DSE9400 series battery charger and a PC running the DSE Configuration Suite software. The operator is then able to view the various operating parameters. NOTE: - For distances up to 6m (8yds) the USB connection method is more suitable and provides for a lower cost alternative to RS485 (which is more suited to longer distance connections). 13

3.3.2.3 OPTIONS FOR CONNECTION TO PCS Brainboxes PM154 PCMCIA RS485 card (for laptops PCs) Set to Half Duplex, Autogating with CTS True set to enabled Brainboxes VX-023 ExpressCard 1 Port RS422/485 (for laptops and nettop PCs) Brainboxes UC320 PCI Velocity RS485 card (for desktop PCs) Set to Half Duplex, Autogating with CTS True set to enabled Brainboxes PX-324 PCI Express 1 Port RS422/485 (for desktop PCs) Supplier: Brainboxes Tel: +44 (0)151 220 2500 Web: http://www.brainboxes.com Email: Sales: sales@brainboxes.com 14

3.5 OUTPUT SPECIFICATIONS 3.5.1 DSE9130 12V 5A Parameter Min Nominal Max Comments Output Voltage (12 V DC battery) 12.5V 13.7V 15.0V Specify float voltage on ordering. Output Charging Current (A) 0A 5A 5.5A Current limit threshold (A) 5A 5.3A 5.5A Recovery from current limit (A) 5A Full load AC input current (A) 1.5A With output at 13.7V DC AC Input Inrush (10ms) current (A) 20A 0.92 DSE9130 Efficiency Curve at 5A 0.9 Efficiency (%) 0.88 0.86 0.84 0.82 0.8 85 110 230 260 Input Voltage (V) 15

3.5.2 DSE9140 12V 10A Parameter Min Nominal Max Comments Output Voltage (12 V DC Battery) 12V 13.7V 15V Output Charging Current (A) 10A 10A 11A Current limit threshold (A) 10A 11A Recovery from current limit (A) 10A 11A Full load AC input current (A) 3.1A At Vin=85V, Vo=13.7V, Io=10Amp Full load AC input current (A) 1.3A At Vin=230V, Vo=13.7V Io=10Amp AC Input Inrush (10ms) current (A) 60A Efficiency (%) 0.87 0.86 0.85 0.84 0.83 0.82 0.81 0.8 0.79 0.78 DSE9140 Efficiency Curve at 10A 85 110 230 260 Input Voltage (V) 16

3.5.3 DSE9150 12V 2A NOTE: This device is no longer available, replaced by DSE9150 12V 3A. See overleaf for updated specifications. Parameter Min Nominal Max Comments Output Voltage (12 V DC Battery) 12.5V 13.7V 13.7V Float voltage not adjustable Output Charging Current (A) 0A 2A 2.5A Current limit threshold (A) 2A 2.3A 2.5A Recovery from current limit (A) 2A Full load AC input current (A) 0.7A With output at 13.7V DC AC Input Inrush (10ms) current (A) 10A 90 DSE9150 Efficiency Curve at 2A 88 86 Efficiency (%) 84 82 80 78 76 74 85 110 230 250 Input Voltage (V) 17

3.5.4 DSE9150 12V 3A NOTE: This device has replaced DSE9150 12V 2A. See previous page for specifications of the earlier model. Parameter Min Nominal Max Comments Output Voltage (12 V DC Battery) 12.5V 13.7V 13.7V Float voltage not adjustable Output Charging Current (A) 0A 3A 3.5A Current limit threshold (A) 3A 3.2A 3.5A Recovery from current limit (A) 3A Full load AC input current (A) 0.7A With output at 13.7V DC AC Input Inrush (10ms) current (A) 10A DSE9153 Efficiency Curve at 3A 0.87 Efficiency (%) 0.86 0.85 0.84 0.83 0.82 0.81 0.80 0.79 110 230 265 Input Voltage (V) 18

3.5.5 DSE9155 30V 2A Parameter Min Nominal Max Comments Output Voltage (30 V DC Battery) 28.0V 34.3V 34.5 Output Charging Current (A) 0A 2.2A 3A Current limit threshold (A) 2A 2.2A 3A Recovery from current limit (A) 2A Full load AC input current (A) 2A AC Input Inrush (10ms) current (A) 30A 0.94 DSE9155 Efficiency Curve at 2A 0.92 0.9 Efficiency (%) 0.88 0.86 0.84 0.82 0.8 0.78 85 110 230 260 Input Voltage (V) 19

3.5.6 DSE9250 24V 3.7A NOTE: - This battery charger is now obsolete, details provided for information only. Parameter Min Nominal Max Comments Output Voltage (24 V DC Battery) 25.0V 27.4V 30.0V Specify float voltage on ordering. Output Charging Current (A) 0A 3.7A 4A Current limit threshold (A) 3.6A 3.75A 4A Recovery from current limit (A) 3.6A Full load AC input current (A) 2A With output at 27.6V DC AC Input Inrush (10ms) current (A) 30A 0.92 DSE9250 Efficiency Curve at 3.7A 0.9 Efficiency (%) 0.88 0.86 0.84 0.82 0.8 85 110 230 260 Input Voltage (V) 20

3.5.7 DSE9255 24V 5A Parameter Min Nominal Max Comments Output Voltage (24 V DC Battery) 25.0V 27.4V 30.0V Specify float voltage on ordering. Output Charging Current (A) 0A 5A Current limit threshold (A) 5A 5.3A 6A Recovery from current limit (A) 5A 5.2A Full load AC input current (A) 0.65A 2.7A With output at 27.6V DC AC Input Inrush (10ms) current (A) 30A 0.94 DSE9255 Efficiency Curve at 5A 0.92 Efficiency (%) 0.9 0.88 0.86 0.84 0.82 0.8 85 110 230 260 Input Voltage (V) 21

3.5.8 DSE9260 24V 10A Parameter Min Nominal Max Comments Output Voltage (12V DC Battery) 26V 27.6V 29V Output Charging Current (A) 10A 11A Current limit threshold (A) 10A 11A Recovery from current limit (A) 9.5A 10A 11A Full load AC input current (A) 2.2A At Vin=230V, Vo=27.6V, Io=10Amp Full load AC input current (A) 5.8A At Vin=85V, Vo=27.6V, Io=10Amp AC Input Inrush (10ms) current (A) 60A For 10ms 0.94 DSE9260 Efficiency Curve at 10A 0.92 0.9 Efficiency (%) 0.88 0.86 0.84 0.82 0.8 0.78 85 110 230 265 Input Voltage (V) 22

3.5.9 DSE9470 (MKII) 24V/12V 10A NOTE: DSE9470 is factory configured to 24V 10A. If required, voltage and current levels can be user configured via DSE Configuration Suite PC Software. Part number 9470-001-00 is fixed at 24V 10A. Parameter Min Nominal Max Comments Output Voltage (24V DC Battery) 26.7V 27V 29V Output Charging Current (A) 2A 10A 11A Current limit threshold (A) 10A 11A Recovery from current limit (A) 10A 11A Full load AC input current (A) 2.3A At Vin=230V, Vo=28.8V, Io=10Amp Full load AC input current (A) 4A At Vin=110V, Vo=28.8V, Io=10Amp AC Input Inrush (10ms) current (A) 60A For 10ms 0.925 0.92 DSE9470 Efficiency Curve at 10A Efficiency (%) 0.915 0.91 0.905 0.9 0.895 0.89 0.885 110 230 277 Input Voltage (V) 12 DSE9470 Smart Charger De-rating Curve 110V < Vin < 305V Output Current (A) 10 8 6 4 2 0-30 -20-10 0 10 20 30 40 50 55 60 65 70 75 80 85 Ambient Temperature ºC 23

DSE9470 Smart Charger De-rating Curve 95V < Vin < 110V 6.0 Output Current (A) 5.0 4.0 3.0 2.0 1.0 0.0-30 -20-10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature (ºC) 24

3.5.10 DSE9472 (MKII) 24V/12V 5A Parameter Min Nominal Max Comments Output Voltage (24V DC Battery) 26.7V 27V 29V Output Charging Current (A) 2A 5A 5.5A Current limit threshold (A) 5A 5.5A Recovery from current limit (A) 5A 5.5A Full load AC input current (A) 1.2A At Vin=230V, Vo=28.8V, Io=5Amp Full load AC input current (A) 2.2A At Vin=110V, Vo=28.8V, Io=5Amp AC Input Inrush (10ms) current (A) 60A For 10ms 93% DSE9472 Efficiency Curve at 5A 92% Efficiency (%) 92% 91% 91% 90% 90% 89% 110 230 277 Input Voltage (V) 6 DSE9472 Smart Charger De-rating Curve 90V < Vin < 305V 5 Output Current (A) 4 3 2 1 0-30 -20-10 0 10 20 30 40 50 55 60 65 70 75 80 Ambient Temperature ( C) 25

3.5.11 DSE9480 (MKII) 12V 10A NOTE: DSE9480 is factory configured to 12V 10A. If required, voltage and currentl levels can be user configured via DSE Configuration Suite PC Software. Part number 9480-001-00 is fixed at 12V 10A. Parameter Min Nominal Max Comments Output Voltage (24V DC Battery) 13.4V 13.5V 14.5V Output Charging Current (A) 2A 10A 11A Current limit threshold (A) 10A 11A Recovery from current limit (A) 10A 11A Full load AC input current (A) 1.2A At Vin=230V, Vo=14.4V, Io=10Amp Full load AC input current (A) 2.2A At Vin=110V, Vo=14.4V, Io=10Amp AC Input Inrush (10ms) current (A) 60A For 10ms Efficiency (%) 92% 91% 91% 90% 90% 89% 89% 88% 88% 87% 87% DSE9480 Efficiency Curve at 10A 110 230 277 Input Voltage (V) 12 DSE9480 Smart Charger De-rating Curve 110V < Vin < 305V Output Current (A) 10 8 6 4 2 0-30 -20-10 0 10 20 30 40 50 55 60 65 70 75 80 85 Ambient Temperature ºC 26

DSE9470 Smart Charger De-rating Curve 95V < Vin < 110V 6.0 Output Current (A) 5.0 4.0 3.0 2.0 1.0 0.0-30 -20-10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature (ºC) 27

3.5.12 DSE9481 (MKII) 12V 5A Parameter Min Nominal Max Comments Output Voltage (24V DC Battery) 13.4V 13.5V 14.5V Output Charging Current (A) 2A 5A 5.5A Current limit threshold (A) 5A 5.5A Recovery from current limit (A) 5A Full load AC input current (A) 0.5A At Vin=230V, Vo=14.4V, Io=5Amp Full load AC input current (A) 1.1A At Vin=110V, Vo=14.4V, Io=5Amp AC Input Inrush (10ms) current (A) 60A For 10ms 93% DSE9481 Efficiency Curve at 5A 92% 92% Efficiency (%) 91% 91% 90% 90% 89% 89% 110 230 277 Input Voltage (V) 6 DSE9481 Smart Charger De-rating Curve 90V < Vin < 305V 5 Output Current (A) 4 3 2 1 0-30 -20-10 0 10 20 30 40 50 55 60 65 70 75 80 Ambient Temperature ( C) 28

3.6 DIMENSIONS AND MOUNTING 3.6.1 DSE907 12V 10A INDUSTRIAL BATTERY CHARGER Parameter Cabinet type Overall size (see below for diagram) Material: Surface finish: Protection category: Weight Mounting type Mounting holes Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature Controls Indication AC Fuse DC Fuse Comment Custom cabinet 200mm x 185mm x 170mm (7.9 x 7.3 x 6.7 ) Add 20mm (0.79 ) to depth when using supplied mounting plate. Sheet steel enclosure of all-round solid construction Powder-coated black IP20 NEMA 1 5.6kg Wall mounting using supplied wall bracket Wall bracket add 20mm (0.79 ) to the depth of the enclosure Diameter 5mm (0.2 ) 130mm (5.1) centres 110V-277V 90V-305V 3A DC resistive 30V maximum -30 C to 55 C (-22 F to 131 F) AC Power on/off 0A-10A DC ammeter Power on Red neon indicator Fuse holder mounted onto front panel. Accepts 2A anti-surge fuse (20mm x 5mm fuse) Fuse holder mounted onto front panel. Accepts 5A anti-surge fuse (20mm x 5mm fuse) 165mm 185mm 130mm 170mm 130mm 170mm add 20mm when fitting supplied wall bracket 200mm Mounting Plate (supplied) Enclosure Dimensions in mm 29

3.6.2 DSE908 12V & 24V 10A CABINET MOUNTED BATTERY CHARGER Parameter Cabinet type Overall size Material: Surface finish: Protection category: Weight Mounting type Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature Controls Indication AC Fuse Comment AE1031.500 by Rittal Rittal website www.rittal.de / www.rittal.co.uk 380mm x 300mm x 210mm (15.0. x 11.8 x 8.3 ) Sheet steel enclosure of all-round solid construction Single door, right hand hinge with one cam lock Foamed-in door seal 1 foamed in gland plate in the enclosure base (Gland plate supplied blank, ready for customer drilling as required). Dipcoat primed, powder-coated on the outside in textured RAL 7035 IP20 NEMA 1 15kg Wall mounting. Can be mounted by customer drilled holes or by using Rittal mounting brackets, suitable for Rittal cabinet type AE1030.500 For example Rittal Part number 2508.010 (Pack of 4) Rittal website www.rittal.de / www.rittal.co.uk 110V-277V 90V-305V 3A DC resistive 30V maximum -30 C to 55 C (-22 F to 131 F) AC Power on/off Boost charge on/off 0A-15A DC ammeter Power on Red neon indicator Fuse holder mounted onto front panel. Accepts 2A anti-surge fuse (20mm x 5mm fuse) 300mm 380mm 210mm Dimensions in mm 30

3.6.3 DSE9130 12V 5A NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres Comment 136.48mm x 140.41mm x 63.40mm (5.37 x 5.53 x 2.5 ) 0.5kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 119.36mm x 128.36mm (4.7 x 5.05 ) Dimensions in mm unless stated 31

3.6.4 DSE9150 12V 2A NOTE: This device is no longer available, replaced by DSE9150 12V 3A. See overleaf for updated specifications. NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres Comment 108.03mm x 101.10mm x 48.6mm (4.25 x 3.98 x 1.91 ) 0.16kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 91mm x 89mm (4.25 x 3.51 ) Dimensions in mm unless stated 32

3.6.5 DSE9150 12V 3A NOTE: This device has replaced DSE9150 12V 2A. See previous page for specifications of the earlier model. NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres Comment 108.03mm x 101.10mm x 48.6mm (4.25 x 3.98 x 1.91 ) 0.16kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 91mm x 89mm (4.25 x 3.51 ) Dimensions in mm unless stated 33

3.6.6 DSE9140 12V 10A NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature Comment 152mm x 188mm x 2.44mm (6 x 7.4 x 2.44 ) 0.75kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 142mm x 128mm (5.59 x 5.0 ) 30mm (1.18 ) from top and bottom edges 5mm (1.97 ) from left and right edges. 110V-277V 90V-305V 3A DC resistive 30V maximum -30 C to 55 C (-22 F to 131 F) 6 in 2.44 in 7.4 in Dimensions in mm unless stated 34

3.6.7 DSE9155 30V 2A NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres Comment 136.48mm x 140.41mm x 63.40mm (5.37 x 5.53 x 2.5 ) 0.5kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 119.36mm x 128.36mm 4.7 x 5.05 Dimensions in mm unless stated 35

3.6.8 DSE9250 24V 3.7A NOTE: - This battery charger is now obsolete, details provided for information only. NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres Comment 136.48mm x 140.41mm x 63.40mm (5.37 x 5.53 x 2.5 ) 0.5kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 119.36mm x 128.36mm (4.7 x 5.05 ) Dimensions in mm unless stated 36

3.6.9 DSE9255 24V 5A NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres Comment 136.48mm x 140.41mm x 63.40mm (5.37 x 5.53 x 2.5 ) 0.5kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 119.36mm x 128.36mm (4.7 x 5.05 ) Dimensions in mm unless stated 37

3.6.10 DSE9260 24V 10A NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature Comment 152mm x 188mm x 2.44mm (6.0 x 7.4 x 2.44 ) 0.85kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 142mm x 128mm (5.59 x 5.0 ) 110V-277V 90V-305V 3A DC resistive 30V maximum -30 C to 55 C (-22 F to 131 F) 6 in 2.44 in 7.4 in Dimensions in mm unless stated 38

3.6.11 DSE9470 (MKII) 24V/12V 10A NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size(mm) Weight Mounting type Din rail type Mounting holes Mounting hole centres Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature Comment 205mm x 135mm x 80mm (8.0 x 5.3 x 3.1 ) 0.78kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 190mm x 120mm (7.5 x 4.7 ) 110V-277V 95V-305V 3A DC resistive 30V maximum -30 C to 85 C with de rating (-22 F to 185 F with de rating) 39

3.6.12 DSE9472 (MKII) 24V/12V 5A NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size(mm) Weight Mounting type Din rail type Mounting holes Mounting hole centres Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature Comment 205mm x 135mm x 80mm (8.0 x 5.3 x 3.1 ) 0.7kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 190mm x 120mm (7.5 x 4.7 ) 110V-277V 95V-305V 3A DC resistive 30V maximum -30 C to 85 C with de rating (-22 F to 185 F with de rating) 40

3.6.13 DSE9480 (MKII) 12V/24V 10A NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size(mm) Weight Mounting type Din rail type Mounting holes Mounting hole centres Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature Comment 205mm x 135mm x 80mm (8.0 x 5.3 x 3.1 ) 0.7kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 190mm x 120mm (7.5 x 4.7 ) 110V-277V 95V-305V 3A DC resistive 30V maximum -30 C to 85 C with de rating (-22 F to 185 F with de rating) 41

3.6.14 DSE9481 (MKII) 12V/24V 5A NOTE: This battery charger is designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. Parameter Overall size(mm) Weight Mounting type Din rail type Mounting holes Mounting hole centres Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature Comment 205mm x 135mm x 80mm (8.0 x 5.3 x 3.1 ) 0.7kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 190mm x 120mm (7.5 x 4.7 ) 110V-277V 95V-305V 3A DC resistive 30V maximum -30 C to 85 C with de rating (-22 F to 185 F with de rating) 42

3.7 APPLICABLE STANDARDS BS 4884-1 This document conforms to BS4884-1 1992 Specification for presentation of essential information. BS 4884-2 This document conforms to BS4884-2 1993 Guide to content. BS 4884-3 This document conforms to BS4884-3 1993 Guide to presentation. BS EN 60068-2-1 (Minimum temperature) -30 C (-22 F) BS EN 60068-2-2 (Maximum temperature) +55 C (131 F) BS EN 60950 Safety of information technology equipment, including electrical business equipment. BS EN 61000-6-2 EMC Generic Immunity Standard (Industrial). BS EN 61000-6-4 EMC Generic Emission Standard (Industrial). BS EN 60529 (Degrees of protection provided by enclosures) UL508 NEMA rating UK WEEE REGULATIONS IP20 Protected against penetration by solid objects with a diameter of more than 12 mm. Fingers or similar objects prevented from approach. No protection against water Enclosure type 1 Provides a degree of protection against contact with the enclosure equipment and against a limited amount of falling dirt Producer Registration Number WEE/BE0052TQ In line with our policy of continual development, Deep Sea Electronics, reserve the right to change specification without notice. 43

Installation 4 INSTALLATION NOTE: The DSE9000 series battery charger should only be used to charge one battery bank at a time. It is not recommended to parallel batteries as the tolerance of the batteries leads to imbalance in their charging. The DSE9000 battery charger is designed to be mounted within a control panel, on the panel DIN rail utilising the integral mounts or on a chassis utilising the mounting holes. For dimension and mounting details, see the section entitled Specification, Dimensions elsewhere in this document. The DSE9000 battery charger is fit-and-forget. It can be permanently connected to the supply and the load, with no requirement to disable the charger during times of heavy load (such as engine cranking) or when the generator is running (even when a DC charging alternator is fitted). 4.1 BATTERY SUITABILITY The standard charger is factory set by DSE to suit Lead Acid batteries but can be adjusted at the time of ordering to suit other battery types. Care should be taken to ensure the batteries connected to the charger are of the correct technology to suit the setting of the charger. For details of other supported battery types and float voltages see the section entitled Specifications, Part Numbering elsewhere in this document. 4.2 USER CONNECTIONS Parameter Comment Connection type Screw terminal, rising clamp, no internal spring Min cable size 0.5mm² (AWG 20) Max cable size 2.5mm² (AWG 14) Recommended AC fuse 230V AC Input 110V AC Input DSE9130 12V 5A charger DSE9140 12V 10A charger DSE9150 12V 2A charger DSE9150 12V 3A charger DSE9155 30V 2A charger DSE9250 24V 3.7A charger DSE9260 24V 10A charger DSE9255 24V 5A charger DSE9470 24V/12V 10A charger DSE9480 12V/24V 10A charger DSE9481 12V 5A charger DSE9472 24V 5A charger 1.0A anti-surge 2.0A anti-surge 1.0A anti-surge 1.5A anti-surge 1.0A anti-surge 1.0A anti-surge 3.5A anti-surge 2.0A anti-surge 3.5A anti-surge 2.0A anti-surge 1.0A antisurge 2.0A antisurge 2.0A anti-surge 3.5A anti-surge 1.5A anti-surge 2.0A anti-surge 2.5A anti-surge 2.5A anti-surge 6.3A anti-surge 3.5A anti-surge 6.3A anti-surge 3.5A anti-surge 2.5A anti-surge 3.5A anti-surge NOTE: Where DSE9470 / DSE9480 current rating has been user configured below 10A, an appropriate fuse size must be selected to match the lower maximum output current. 44

Installation 4.2.1 DSE9130, DSE9140, DSE9250, DSE9255 & DSE9260 Connector A Terminal Function Recommended Size Comments -OP Load negative 1mm² (AWG 16) Battery negative terminal +OP Load Positive 1mm² (AWG 16) Battery positive terminal BOOST Boost mode 0.5 mm² (AWG 22) BOOST Boost mode 0.5 mm² (AWG 22) Connect together for boost operation CF Charge failure relay 0.5 mm² (AWG 22) CF Charge failure relay 0.5 mm² (AWG 22) Closes under charge fail conditions Connector B Terminal Function Recommended Size Earth 1mm² (AWG 16) N AC Neutral 1mm² (AWG 16) L AC Live 1mm² (AWG 16) CAUTION: Ensure Earth Terminal is connected to Battery negative (for negative earth systems) or Battery positive (for positive earth systems) Where no system earth exists, Earth Terminal must be connected to battery negative 4.2.2 DSE9150 Connector A Terminal Function Recommended Size Comments NC Not Connected Do not connect -OP Load negative 1mm² (AWG 16) Battery negative terminal +OP Load Positive 1mm² (AWG 16) Battery positive terminal Connector B Terminal Function Recommended Size Earth 1mm² (AWG 18) N AC Neutral 1mm² (AWG 18) L AC Live 1mm² (AWG 18) CAUTION: Ensure Earth Terminal is connected to Battery negative (for negative earth systems) or Battery positive (for positive earth systems) Where no system earth exists, Earth Terminal must be connected to battery negative 45

Installation 4.2.3 DSE9155 Connector A Terminal Function Recommended size Comments -OP Load negative 1mm² (AWG 16) Battery negative terminal +OP Load Positive 1mm² (AWG 16) Battery positive terminal BOOST N/A 0.5 mm² (AWG 22) BOOST N/A 0.5 mm² (AWG 22) Boost not avaialble on DSE9155 CF Charge failure relay 0.5 mm² (AWG 22) CF Charge failure relay 0.5 mm² (AWG 22) Closes under charge fail conditions Connector B Terminal Function Recommended Size Earth 1mm² (AWG 16) N AC Neutral 1mm² (AWG 16) L AC Live 1mm² (AWG 16) CAUTION: Ensure Earth Terminal is connected to Battery negative (for negative earth systems) or Battery positive (for positive earth systems). Where no system earth exists, Earth Terminal must be connected to battery negative. 46

Installation 4.2.4 DSE9470 MKII, DSE9472 MKII, DSE9480 MKII, DSE9481 MKII NOTE: For obsolete parts 9470-001-00 and 9480-001-00 contact DSE Technical Support for connection details. Connector A Terminal Function Recommended size Comments -OP Load negative 1mm² (AWG 16) Battery negative terminal +OP Load Positive 1mm² (AWG 16) Battery positive terminal Connector B Terminal Function Recommended size Comments LK1 Configurable Input 1mm² (AWG 16) Connect the terminals together to activate the input. The Factory Setting for the digital input provides a selection of 12V / 24V operation. Customer configurable using DSE Configuration Suite PC Software. LK1 Configurable Input (0V) 1mm² (AWG 16) NOTE: Digital Input Not Fitted to 9470-001-00 and 9480-001-00. NC COM NO Normally Closed Contact of the Charge failure relay Charge failure relay Contact Common Normally Open Contact of the Charge failure relay 0.5 mm² (AWG 22) 0.5 mm² (AWG 22) 0.5 mm² (AWG 22) Changes State Under Charge Fail Conditions NOTE: For further details of PC Configuration, you are referred to DSE Publication: 057-159 DSE9400 Series Battery Charger Configuration Suite Manual. 47

Installation Connector B Terminal Function Recommended size Comments SCR RS485 screen 0.5mm² (AWG20) Use only 120Ω RS485 approved cable A RS485 -ve 0.5mm² (AWG20) Use only 120Ω RS485 approved cable B RS485 +ve 0.5mm² (AWG20) Use only 120Ω RS485 approved cable NTC PT1000 connection 0.5mm² (AWG20) NTC terminals 0.5mm² (AWG20) Use only PT1000 Connector C Terminal Function Recommended Size Earth 1mm² (AWG 16) N AC Neutral 1mm² (AWG 16) L AC Live 1mm² (AWG 16) CAUTION: Ensure Earth Terminal is connected to Battery negative (for negative earth systems) or Battery positive (for positive earth systems) Where no system earth exists, Earth Terminal must be connected to battery negative 48

Installation 4.3 TYPICAL WIRING DIAGRAM 4.3.1 DSE9150 DSE9150 Recommended AC fuse 230V AC Input 110V AC Input DSE9150 12V 2A charger (see Note below) 1.0A anti-surge 1.5A anti-surge DSE9150 12V 3A charger 1.5A anti-surge 2.0A anti-surge NOTE: DSE9150 12V 2A is no longer available and is included for legacy support only. 49

Installation 4.3.2 DSE9155 & DSE9200 SERIES Recommended AC fuse 230V AC Input 110V AC Input DSE9130 12V 5A charger DSE9140 12V 10A charger DSE9155 30V 2A charger DSE9250 24V 3.7A charger DSE9260 24V 10A charger DSE9255 24V 5A charger 1.0A anti-surge 2.0A anti-surge 1.0A anti-surge 1.0A anti-surge 3.5 A anti-surge 2.0A anti-surge 2.0A anti-surge 3.5A anti-surge 2.5A anti-surge 2.5A anti-surge 6.3A anti-surge 3.5A anti-surge 50

Installation 4.3.3 DSE9470 MKII, DSE9472 MKII, DSE9480 MKII, DSE9481 MKII NOTE: For obsolete parts 9470-001-00 and 9480-001-00 contact DSE Technical Support for connection details. Recommended AC fuse DSE9470 24V/12V 10A DSE9480 12V/24V 10A DSE9481 12V/24V 5A DSE9472 24V/12V 5A 230V AC Input 3.5A antisurge 3.5A antisurge 1.0A antisurge 2.0A antisurge 110V AC Input 6.3A antisurge 6.3A antisurge 2.5A antisurge 3.5A antisurge 51

Operation 5 INDICATIONS DANGER OF DEATH : LIVE PARTS exist within the DSE9000 enclosure. The enclosure cover must not be removed when connected to an AC supply. 5.1 DSE907 Charge Ammeter Power Indication Function Power indication Charge Ammeter Action Illuminated RED when AC power is connected and the POWER switch is in the 1 position Scaled 0A to 10A to show charge current (Max 5A charge) 5.2 DSE908 Power Indication Charge Ammeter Function Power indication Charge Ammeter Action Illuminated RED when AC power is connected and the POWER switch is in the ON position Scaled 0A to 15A to show charge current (Max 5A charge) 52

Operation 5.3 DSE9130, DSE9150, DSE9155, DSE9250 & DSE9255 DSE9130 12V 5A DSE9155 30V 2A DSE9250 24V 3.7A DSE9255 24V 5A DSE9150 12V 2A DSE9150 12V 3A Charger Status Charger Status LED Indications Function Colour Action Charger Status Red Off when AC supply is not present or output volts are too low. Steady during normal operation with AC supply above minimum operating voltage. Flashing when connected to an operating charging alternator. Pulsing during overload conditions. 53

Operation 5.4 DSE9140 & DSE9260 DSE9140 12V 10A DSE9260 24V 10A Charger Status Short Circuit LED Indications Function LED Action Charger Status Red Off when AC supply is not present or output voltage is too low Steady during normal operation with AC supply above minimum operating voltage Flashing when connected to an operating charging alternator Off when AC supply is not present or output voltage is too low Short circuit and Steady during normal operation with AC supply above reverse polarity Green minimum operating voltage indication Flashing during short circuit or reverse polarity conditions 54

Operation 5.5 DSE9470 MKII, DSE9472 MKII, DSE9480 MKII, DSE9481 MKII NOTE: For obsolete parts 9470-001-00 and 9480-001-00 contact DSE Technical Support for LED descriptions. Boost Voltage potentiometer access hole Charger Status (OPE) Fault LEDs 5.5.1 STATUS Condition LED DESIGNATION OPE FAULT 1 FAULT 2 Charger Off Off Off Off Battery not Detected (Battery Detection Mode) Green Red Red Battery Connected (Battery Detection Mode) Not Charging (Charger is operating correctly but the ouput has been disconnected from the battery) Constant Green Constant Off Constant Red Constant Red Constant Flashing Red Constant Red Constant 5.5.2 CHARGE MODE Mode Bulk Charge in progress Absorption Charge in progress Float Charge in Progress Storage Charge in Progress LED DESIGNATION OPE Yellow Constant Yellow Flashing Green Constant Green Flashing 5.5.3 FAULT CONDITIONS Condition High Output Voltage (DC) High / Low Input Voltage (AC) or High Output Current (DC) High Ambient / Charger Temperature, High Battery Temperature (if enabled) Short Circuit/ Reverse Polarity (DC Output Connection) LED DESIGNATION FAULT 1 FAULT 2 Red Constant Off Red Flashing Off Off Red Constant Off Red Flashing 55

Operation 6 OPERATION 6.1 OPERATION OF DSE9100 SERIES / DSE9200 SERIES DSE9100 SERIES DSE9200 SERIES DSE9130 12V 5A DSE9250 24V 3.7A DSE9140 12V 10A DSE9255 24V 5A DSE9150 12V 2A DSE9260 24V 10A DSE9150 12V 3A DSE9155 30V 2A The DSE9100 & DSE9200 series of battery chargers can be used as a battery charger, DC power supply, or both at the same time. For instance, the units can be used to power the generator control panels and charge the panel batteries or starter batteries at the same time. With no AC input to the charger, the Charge fail relay will be closed. This can be used to provide indication of charger failure which operates upon mains supply AC supply failure or upon one of the protections being activated. 6.1.1 PROTECTION Current limit to charger specification (2A or 3A depending upon charger model) Short circuit protection. Charger automatically restarts operation after the fault is removed. Reverse battery polarity protection. Charger automatically restarts operation after the fault is removed. 6.1.2 PSU MODE If no battery is connected to the output terminals, the DSE9100 & DSE9200 series battery charger will operate as a DC power supply only, current limit is factory set. See the section entitled Specification elsewhere in this manual for output specifications. 6.1.3 CHARGE MODE Constant Voltage The DSE9100 & DSE9200 series battery charger operates in Constant voltage current limited mode. The charger output voltage is maintained at a constant level to allow the battery to charge while the load does not exceed the maximum rating of the charger. Once the battery is fully charged, the DSE9100 & DSE9200 series battery charger will switch to ECO- POWER mode. This is a low power use standby mode. Current Limit If the load on the battery charger (battery charge demand+standing load) exceeds the maximum current rating of the charger, the charging current is limited to the maximum rating of the charger and the voltage is reduced. The voltage will rise to the rated voltage again once the load drops below the maximum rating of the charger. 56

Operation Charging time Charge time is often of little consequence when the battery is used in a standby operation. An example of this is when the battery is used to supply the starting system of a diesel generator. During normal operation, the battery is at full capacity and the battery charger is used to maintain the float voltage of the battery. The battery is only drained when the generator is called to start. As the generator has a DC charging alternator fitted, the battery is quickly recharged when the generator is running. Should the generator stop before the battery is fully recharged, the DSE9100 & DSE9200 series will continue to recharge the battery until it is fully charged. Typically a battery will charge from flat to 80% capacity in 16hrs when when charged at C/10. For example charging a 50Ah battery for 16hrs at 5A will charge the battery to 80% of its full capacity. Remember to take into account any other standing load such as control panel requirements when calculating how much power is left to charge the battery. 6.1.4 BOOST MODE (Not applicable to DSE9150 12V 2A, DSE9150 12V 3A or DSE9155 30V 2A) CAUTION: Boost mode is intended for equalisation of the cells in lead acid batteries and should not be operated when the battery charger is connected to other battery types or when the charger is used as a power supply only. If in doubt, consult your battery manufacturer. Boost mode is operated by connecting the BOOST terminals together (for instance with an external switch or timer circuit). This will raise the battery charger floating voltage by 0.8V DC. 57

Operation 6.2 OPERATION OF DSE9400 MKII SERIES DSE9400 SERIES DSE9470 MKII 24V/12V 10A DSE9472 MKII 24V/12V 5A DSE9480 MKII 12V/24V 10A DSE9481 MKII 12V/24V 5A The DSE9400 MKII Series battery charger can be used as a battery charger, DC power supply, or both at the same time. For instance, the unit can be used to power the generator control panels and charge the panel batteries or starter batteries at the same time. With no AC input to the charger, the Fault relay is in it s inactive state. This volts-free change over relay can be used to provide indication of alarms as detailed in the Protection section below. When a suitable AC supply is connected, operation of the unit will depend upon the load connected to the unit s output terminals : NOTE: For details of Battery Charger Configuration, you are referred to DSE Publication: 057-159 DSE9400 Series Battery Charger Configuration Suite Manual. 6.2.1 PROTECTION Alarms fall into two categories : Factory Configured, non-ajustable alarms. User Configurable Alarms, adjustable by DSE Configuration Suite PC Software. 6.2.1.1 FACTORY CONFIGURED ALARMS Under the following conditions, the Fault Relay de-energises and charging is stopped (DC output is disabled) : Mains voltage > 310V (rms) Mains voltage < 85V (rms) Battery temperature > 60 ºC (if temperature compensation is enabled) Battery Charger ambient temperature> 85 ºC DC output voltage > 110% of Boost Voltage Short circuit / reverse polarity of the DC output. 6.2.1.2 USER CONFIGURABLE ALARMS NOTE: For details of Battery Charger Configuration, you are referred to DSE Publication: 057-159 DSE9400 Series Battery Charger Configuration Suite Manual. The following alarms are user configurable using DSE Configuration Suite PC Software. In each case, the Fault relay de-energises. DC Overcurrent alarm DC Overvoltage alarm Battery Temperature alarm. Activation of this alarm places the charger into Float mode. Mains Over Voltage alarm. Activation of this alarm places the charger into Float mode. Mains Under Voltage alarm. Activation of this alarm places the charger into Float mode. 58

Operation 6.2.2 DIGITAL INPUT The DSE9400 series is fitted with a configurable digital input. Configuration is made using the DSE Configuration Suite PC Software. The Factory Setting for the digital input provides a 12V / 24V selection function. 6.2.3 VOLTAGE ADJUSTMENT POTENTIOMETER A manually operated potentiometer is provided to make small adjustments to the Boost Voltage without the requirement for the DSE Configuration Suite PC Software. This is primarily intended to increase charger output to cater for voltage drop in long connection cables. The potentiometer adjusts the boost voltage byup to ±1.7V. This is subject to an absolute maximum of 29.5V. The table below shows the effect of the potentiometer on the boost voltage in the various charging modes. Charge Mode Bulk Absorption Float Storage Effect on boost voltage 100% of potentiometer setting 50% of potentiometer setting Potentiometer has no effect on Float Voltage Potentiometer has no effect on Storage Voltage 6.2.4 PSU MODE If no battery is connected to the output terminals, the battery charger will operate as a DC power supply only, current limit is factory set to 10A and is adjustable (2A 10A) using the DSE Configuration Suite PC Software. See the section entitled Specification elsewhere in this manual for further output specifications. 59

Operation 6.2.5 CHARGE MODE NOTE: For details of Battery Charger Configuration, you are referred to DSE Publication: 057-159 DSE9400 Series Battery Charger Configuration Suite Manual. NOTE: Should a 2-Stage charging profile be required, select a 3-Stage profile and configure Boost Voltage and Float Voltage to the same value. Using DSE Conifiguration Suite PC Software, the battery charger is configured to use either a 3- Stage Charge or 4-Stage Charge profile as shown below. The description of each charge mode is given in the following sections. Bulk Absorption Float Bulk Absorption Float Storage 3-Stage Charge Profile Configuration 4-Stage Charge Profile Configuration 6.2.5.1 BULK CHARGE The battery charger operates in Constant voltage current limited mode. The charger output voltage is maintained at a constant level (boost voltage) to allow the battery to charge while the load does not exceed the maximum rating of the charger. If the load on the battery charger (battery charge demand+standing load) exceeds the maximum current rating of the charger, the charging current is limited to the maximum rating of the charger and the voltage is reduced. The voltage will rise to the rated voltage again once the load drops below the maximum rating of the charger. This may occur naturally as the battery charges. As the battery charges and the charge current drops below 75% of the current rating, Absorption mode is entered. 6.2.5.2 ABSORPTION This mode is active for the duration of the Absorption Timer. This is adjustable using the DSE Configuration Suite PC Software. Absorption mode is used to complete the charging process, bringing the battery to 100% charged status. After the Absorption timer, float charge mode is entered. 60

Operation 6.2.5.3 FLOAT CHARGE The battery charger DC voltage is lowered to the configured float voltage. Float Charge is used to provide a small amount of current to the battery, to overcome internal losses and keep the battery at it s 100% charged state. The battery can be left in this mode indefinitely. 6.2.5.4 STORAGE When configured to use a four stage charging profile, a time limited storage charge is periodically entered (storage timer) to maintain the battery charge at optimum levels. This occurs at the level of the storage voltage. This is adjustable using the DSE Configuration Suite PC Software. When the storage timer expires, the charger re-enters the Absorption mode. Additionally, this is used as an Automatic Boost facility, to periodically attempt to remove sulfation from the battery plates. 6.2.5.5 CHARGING TIME Charge time is often of little consequence when the battery is used in a standby operation. An example of this is when the battery is used to supply the starting system of a diesel generator. During normal operation, the battery is at full capacity and the battery charger is used to maintain the float voltage of the battery. The battery is only drained when the generator is called to start. As the generator has a DC charging alternator fitted, the battery is quickly recharged when the generator is running. Should the generator stop before the battery is fully recharged, the DSE9400 MKII Series battery charger will continue to recharge the battery until it is fully charged. Typically a battery will charge from flat to 80% capacity in 16hrs when when charged at C/10. For example charging a 50Ah battery for 16hrs at 5A will charge the battery to 80% of its full capacity. Remember to take into account any other standing load such as control panel requirements when calculating how much power is left to charge the battery. 6.2.5.6 MANUAL BOOST NOTE: The Digital Input must be configured to Manual Boost to provide this function. For further details, you are referred to DSE Publication: 057-159 DSE9400 Series Battery Charger Configuration Suite Manual. Manual boost will place the charger into Bulk Charge mode, charging at the level of the boost voltage. A typical use of manual boost is with Lead Acid type batteries. When the battery is fully charged, placing the charger into boost mode will raise the output voltage. This has the effect of gassing the battery, helping to remove sulfation from the battery plates and helping the cells to equalise in voltage. 6.2.6 TEMPERATURE COMPENSATION NOTE: For details of Battery Charger Configuration, you are referred to DSE Publication: 057-159 DSE9400 Series Battery Charger Configuration Suite Manual. If temperature compensation is enabled through configuration, and remote temperature sensor is connected, the output voltage automatically varies by a configureable voltage per cell for each 1 C deviation from 20 C, within the range of -20 C to 60 C. Increasing temperature gives decreasing output voltage and increasing temperatures gives increasing output voltage.. The battery temperature is measured by a 2 wire PT1000 sensor placed on the battery itself. 61

Fault Diagnosis 7 FAULT DIAGNOSIS Nature of problem The charger is not operating Charge fail relay continuously operated Batteries fail to charge Charge time is too long Suggestion Check that the incoming AC supply is correctly connected and within limits and check the integrity of any external fuse that may be fitted. Ensure the charger is not being operated above the maximum temperature specification. Check the LED indications against the LED descriptions listed elsewhere in this document. Check the connected load of the charger is not reverse connected or short circuit. Check the batteries using the battery manufacturers recommendations. Typically a battery will charge from flat to 80% capacity in 16hrs when when charged at C/10. For example charging a 50Ah battery for 16hrs at 5A will charge the battery to 80% of its full capacity. Remember to take into account any other standing load such as control panel requirements when calculating how much power is left to charge the battery. 62

This page is intentionally left blank. 8 MAINTENANCE, SPARES, REPAIR AND SERVICING The DSE battery chargers are designed to be Fit and Forget. As such, there are no user serviceable parts. In the case of malfunction you should contact your original equipment supplier (OEM). 9 WARRANTY DSE provides limited warranty to the equipment purchaser at the point of sale. For full details of any applicable warranty, you are referred to your original equipment supplier (OEM). 10 DISPOSAL 10.1 WEEE (WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT) Directive 2002/96/EC If you use electrical and electronic equipment you must store, collect, treat, recycle and dispose of WEEE separately from your other waste. 10.2 ROHS (RESTRICTION OF HAZARDOUS SUBSTANCES) Directive 2002/95/EC:2006 To remove specified hazardous substances (Lead, Mercury, Hexavalent Chromium, Cadmium, PBB & PBDE s) Exemption Note: Category 9. (Monitoring & Control Instruments) as defined in Annex 1B of the WEEE directive will be exempt from the RoHS legislation. This was confirmed in the August 2005 UK s Department of Trade and Industry RoHS REGULATIONS Guide (Para 11). Despite this exemption DSE has been carefully removing all non RoHS compliant components from our supply chain and products. When this is completed a Lead Free & RoHS compatible manufacturing process will be phased into DSE production. This is a process that is almost complete and is being phased through different product groups. 63

This page is intentionally left blank.

DSE DSE9470, DSE9472, DSE9480 & DSE9481 MKll INTELLIGENT BATTERY CHARGERS 5 AMP & 10 AMP, 12 VOLT & 24 VOLT OPTIONS FEATURES The DSE9400 series is a range of intelligent battery chargers that can be programmed for different charging curves to maximise the life of the battery. The DSE9400 series of intelligent battery chargers are programmed using the user-friendly DSE Configuration Suite PC software. The chargers can be either DIN rail or chassis mounted, using the fixing holes that are built into the case. The charger s stylish design includes three coloured LEDs to indicate charging status and fault conditions. The chargers do not include any moving parts to give added durability and reliability. They will also continue to operate during engine running. Multiple modules can be linked together to provide a larger current output. ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment OPERATING TEMPERATURE RANGE BS EN 60068-2-1 Ab/Ae Cold Test -30 o C BS EN 60068-2-2 Bb/Be Dry Heat +80 o C * Refer to de-rating curve in the DSE9000 Operator Manual VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn HUMIDITY BS EN 60068-2-30 Db Damp Heat Cyclic 20/55 o C @ 95% RH 48 Hours BS EN 60068-2-78 Cab Damp Heat Static 40 o C @ 93% RH 48 Hours SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 ms COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF BATTERY CHARGER APPLICATIONS 1ph N CHARGE OUTPUT USB PORT RS485 AC POWER SUPPLY COMPATIBLE WITH ALL DSE MODULES DSE9470, DSE9472, DSE9480 & DSE9481 TEMPERATURE SENSOR VOLT FREE CHANGE OVER FAULT OUTPUT CONFIGURABLE INPUT PT1000 ONLY 1 1

DSE DSE9470, DSE9472, DSE9480 & DSE9481 MKll INTELLIGENT BATTERY CHARGERS 5 AMP & 10 AMP, 12 VOLT & 24 VOLT OPTIONS FEATURES SPECIFICATION AC SUPPLY VOLTAGE RANGE 90 V to 305 V (L-N) FREQUENCY RANGE 48 Hz to 64 Hz (L-N) DC OUTPUT DSE9470 OUTPUT 10 A DC at 24 V DC DSE9472 OUTPUT 5 A DC at 24 V DC DSE9480 OUTPUT 10 A DC at 12 V DC DSE9481 OUTPUT 5 A DC at 12 V DC RIPPLE AND NOISE <1% EFFICIENCY >86% REGULATION LINE <0.5% LOAD 2% ADVANCED FEATURES Intelligent three and four stage charging profiles Configurable to suit 12V and 24V applications Adjustable current limit (Max 10A) Can be used as a battery charger, power supply or both at the same time Automatic or manual boost and storage charge functions to help maintain battery condition Digital microprocessor technology Temperature compensation for battery charging Low output ripple and superb line regulation Three LED indicators Switched mode design Fully customisable battery charging curves AC input under voltage AC input over voltage Battery charger output over voltage Battery charger output over current Battery under voltage alarm Automatic battery detection Automatic battery charger self test Output short circuit and inversion polarity with auto recovery Automatic power de-rating at high ambient temperatures. Optional battery temperature compensation using PT1000 temperature sensor with over temperature protection Boosts and equalises cell charge, improving battery performance and life Once the battery is fully charged, the chargers switch to ecopower to save energy Can be integrated into external systems through MODBUS RTU using RS485 Fully configurable via DSE Configuration Suite PC Software External remote display option - DSE2541 KEY BENEFITS Fully flexible to maximise the life of the battery Suitable for a wide range of battery types Minimum 86% efficiency throughout full operating range No external intervention for boost mode Multiple chargers can be linked together to provide larger current output Can be permenantly connected to battery and AC supply. No need to disconnect through high load conditions such as cranking or when the engine is running. TEMPERATURE SENSOR INPUT PT1000 PROTECTIONS Short Circuit DC Over Voltage DC Over Current Reverse Polarity Over Temperature AC Under & Over Voltage CHARGE FAILURE RELAY 3 A at 30 V DC volt free relay DIMENSIONS OVERALL 70 mm x 200 mm x 130 mm 2.7 x 7.9 x 5.1 WEIGHT 0.75 kg OPERATING TEMPERATURE RANGE -30 o C to +55 o C STORAGE TEMPERATURE RANGE -30 o C to +70 o C RELATED MATERIALS TITLE PART NO S DSE9400 Series Configuration Suite PC Software Manual 057-159 DSE Configuration Suite Installation & Operator Manual 057-151 DSE9000 Series Installation Instructions 057-049 DSE9000 Series Operator Manual 057-085 DEEP SEA ELECTRONICS PLC UK Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com DEEP SEA ELECTRONICS INC USA 3230 Williams Avenue, Rockford, IL 61101-2668 USA TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708 EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change the details shown on this data sheet without prior notice. The contents are intended for guidance only. Registered in England & Wales No.01319649 VAT No.316923457 055-158/03/13 (4)

Dimensions and Mounting DSE9150 12V 3A Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres 108mm x 101mm x 49mm (4.25 x 3.98 x 1.91 ) 0.16kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 91mm x 89mm (4.25 x 3.51 ) 110V-240V 90V-250V Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature -30 C to 55 C (-22 F to 131 F) Dimensions in mm unless stated 3A DC resistive, 30V maximum Connection type Screw terminal, rising clamp, no internal spring Min cable size 0.5mm² (AWG 20) Max cable size 2.5mm² (AWG 14) Recommended AC fuse 230V AC Input 110V AC Input DSE9130 12V 5A charger DSE9140 12V 10A charger DSE9150 12V 3A charger DSE9155 30V 2A charger DSE9250 24V 3.7A charger DSE9255 24V 5A charger DSE9260 24V 10A charger DSE9470 MKII 24V 10A charger DSE9472 MKII 24V 5A charger DSE9480 MKII 12V 10A charger DSE9481 MKII 12V 5A charger 1.0A anti-surge 2.0A anti-surge 1.0A anti-surge 1.0A anti-surge 1.0A anti-surge 2.0A anti-surge 3.5A anti-surge 3.5A anti-surge 2.0A antisurge 2.0A anti-surge 1.0A antisurge 2.0A anti-surge 3.5A anti-surge 1.5A anti-surge 2.5A anti-surge 2.5A anti-surge 3.5A anti-surge 6.3A anti-surge 6.3A anti-surge 3.5A anti-surge 3.5A anti-surge 2.5A anti-surge 053-049 ISSUE 13 DSE9xxx Battery Charger Installation Instructions Typical Wiring Diagrams DEEP SEA ELECTRONICS DANGER OF DEATH : LIVE PARTS exist within the DSE9xxx enclosures. The enclosure cover must not be removed. Installation The DSE9xxx battery chargers are designed to be mounted within a control panel, on the panel DIN rail utilising the integral mounts or on a chassis utilising the mounting holes. For dimension and mounting details, see overleaf. The DSE9xxx battery chargers are fit-and-forget. It can be permanently connected to the supply and the load, with no requirement to disable the charger during times of heavy load (such as engine cranking) or when in parallel with a charging alternator. Battery suitability The charger is factory set by DSE to suit Lead Acid batteries. The DSE91xx & DSE92xx battery chargers can be adjusted at the time of ordering to suit other battery types. The DSE947x MKII & DSE948x MKII battery chargers are configured using the DSE Configuraiton Suite to suit other battery types. Care should be taken to ensure the batteries connected to the charger are of the correct technology to suit the setting of the charger. Indications The DSE9xxx Battery Chargers feature an LED indicator(s) to show the battery charger Status. (Refer to DSE publication: 057-085 DSE9xxx Series Operator Manual for further information) Boost Mode (Not applicable to DSE9150 12V 2A or DSE9155 30V 2A) (DSE947x & DSE948x MKII Series Only. Boost feature is controlled automatically, no external connection needed.) Boost mode is operated by connecting the BOOST terminals together (for instance with an external switch or timer circuit. This will raise the battery charger floating voltage by 0.8V DC. Caution:- Boost mode is intended for equalisation of cells in lead acid batteries. DSE 91xx & 92xx Series Battery Chargers CF not available on DSE9150 12V 2A Boost not available on DSE9150 12V 3A DSE9155 30V 2A DSE 947x & 948x MKII Battery Chargers

Dimensions and Mounting DSE9130 12V 5A DSE9250 24V 3.7A * DSE9155 30V 2A DSE9255 24V 5A * This model is no longer available Overall size Weight Mounting type Din rail type Mounting holes Mounting hole centres Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature 136mm x 140mm x 63mm (5.37 x 5.53 x 2.5 ) 0.5kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 119.36mm x 128.36mm (4.7 x 5.05 ) DSE9250-001 24V 3.7A DSE9250-002 24V 3.7A DSE9130 12V 5A DSE9255 24V 5A DSE9250-001 24V 3.7A DSE9250-002 24V 3.7A DSE9130 12V 5A DSE9255 24V 5A 3A DC resistive, 30V maximum -30 C to 55 C (-22 F to 131 F) 110V-240V 110V-277V 110V-277V 110V-277V 90V-265V 90V-305V 90V-305V 90V-305V Dimensions and Mounting DSE9140 12V 10A DSE9260 24V 10A Overall size Weight DSE9140 12V 10A DSE9260 24V 10A Mounting type Din rail type Mounting holes Mounting hole centres 152mm x 188mm x 62mm (6 x 7.4 x 2.44 ) 0.75kg 0.85kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 142mm x 128mm (5.59 x 5.0 ) 110V-277V 90V-305V Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature -30 C to 55 C (-22 F to 131 F) 6in 3A DC resistive 30V Maximum 2.44in Dimensions and Mounting Intelligent Battery Chargers DSE9481 MKII 12V 5A DSE9472 MKII 24V 5A Overall size Weight DSE9470 MKII DSE9472/80/81 MKII Mounting type Din rail type Mounting holes Mounting hole centres Input voltage (nominal) Input voltage (absolute range) Charge failure relay rating Operating Temperature Optional Temperature Sensor Communications PC connection (USB) DSE9480 MKII 12V 10A DSE9470 MKII 24V 10A 205mm x 135mm x 80mm (8.1 x 5.3 x 3.1 ) 0.78kg 0.7kg DIN rail or chassis mounting EN 50022 35mm type only Suitable for M4 190mm x 120mm (7.5 x 4.7 ) 110V-277V 95V-305V 3A DC resistive 30V maximum -30 C to 85 C with de-rating (-22 F to 185 F) NTC connections for PT1000 sensor only RS485 To enable PC Configuration 7.4 in Dimensions in mm unless stated Dimensions in mm unless stated Dimensions in mm unless stated Deep Sea Electronics Plc. Tel:+44 (0)1723 890099 Fax: +44 (0)1723 893303 Email: sales@deepseaplc.com Web: www.deepseaplc.com Deep Sea Electronics Inc. Phone: +1 (815) 316-8706 Fax: +1 (815) 316-8708 Email: sales@deepseausa.com Web: www.deepseausa.com NOTE : DSE9000 series chargers are designed to be mounted with the base to a vertical surface with the terminal strips at the bottom. NOTE : This document is intended as a quick start guide only. For full operating instructions and specifications, refer to DSE publication: 057-085 DSE9xxx Series Operator Manual