AUTOMATIC FILTER & STRAINER SELECTION PG. 3 FI SERIES SINGLE BAG FILTER HOUSINGS PG. 4 FI MULTI BAG FILTER HOUSINGS PG. 6

Similar documents
Series 774 Automatic Skid Package

Automatic Self-Cleaning Strainer/Filter Systems

Basket Strainers. Applications. Pressures to 3705 PSIG. Temperatures to 800ºF FEATURES MATERIALS OF CONSTRUCTION END CONNECTIONS SIZES RATINGS

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

Automatic Self-Cleaning Strainer/Filter Systems

Subject title Pipeline Strainers Cover subheadline Titel_englisch.indd :42:10 Uhr

Rosedale Model HSS300 and HSS750 Single Cartridge Housings for Liquids

RP-CS 2-98 CERTA-SEAL LIQUID BAG FILTERS WITH THE MATCHED PERFORMANCE DESIGN. Products

Fabricated Duplex Strainers

AutoFilt RF3 Automatic Self-Cleaning Filter

AutoFilt RF3 Automatic Self-Cleaning Filter

Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System

PRODUCT BROCHURE AUTOMATIC AND MANUAL. filtration systems BOLLFILTER UK LIMITED

Cartridge Filter Housings Nowata A Series

Series RFLD Duplex In-Line Filter

Suction Diffusers. Applications PROTECTION PUMP. Pressures to 790 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZE RANGES RATINGS

Series RFL In-Line Filter

Fabricated Tee Strainers Style T & TQ; 150#, 300# and 600# Flanged or Butt Weld Connections...6 Technical Data...7

Distributed By: M&M Control Service, Inc

HAYWARD FILTRATION AUTOMATIC SELF-CLEANING & FABRICATED PIPELINE STRAINERS

TStrainers. Applications. Pressures to 3705 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZES RATINGS

FILTERS, STRAINERS AND VALVES PRODUCT GUIDE

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.

HIGH PRESSURE FILTERS

Backwashable Filter Systems ProGuard 2000 Series

HIGH PRESSURE FILTERS

To ensure proper installation, digital pictures with contact information to before startup.

HIGH PRESSURE FILTERS

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

Temporary Strainers. Applications. Pressures to 3705 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZES

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

Spin Klin 12" Super Flow

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

The Anatomy of a Drum Filter

MAHLE Automatic Filter Series R8-30W

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

Technical Data. Series Oval Flowmeter. Model 9400

ARKAL FILTERS CATALOGUE

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

Liquid Strainers. Protect nozzles, valves and pumps from damaging debris. Experts in Spray Technology Spray Nozzles. Spray Fabrication.

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

PRESSURE REDUCING CONTROL VALVE

YStrainers. Applications. Pressures to 3705 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS RATINGS SIZES

PRESSURE GAGES AND TEST TAPS

HIGH PRESSURE FILTERS

PRESSURE REDUCING VALVE

Overview of Technical Advantages and Product Design. G.S. Presser, P. Eng. November 2004

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

NFH Low Pressure Filters

Crosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure.

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

Industrial Turbo Meters, Sizes 2" through 6"

VAF TM FILTRATION SYSTEMS HYDROCYCLONE SEPARATOR

Backflushing Filter AutoFilt RF3

BERMAD Irrigation. Media Filtration Systems. Model Filters. Features and Benefits. Typical Applications

BGT Series. Low Pressure Filters

Automatic Back-Flushing Filter for Process Technology AutoFilt RF3.

LAKOS AUTOMATIC SELF-CLEANING SCREEN FILTERS

DESIGNER S GUIDE STRAINERS INTERNATIONAL

Thompson Strainer MLS-2

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS

Process Inline Filter Protective filter PLF2-9HF

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

UNIVERSAL PRODUCT LINE: STAINLESS STEEL NON-JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE:

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

2900 MPV Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

PUMPS AND FILTRATION

MAP Automatic Strainers In-Line Series

AURORA FILTERS. - S 316L Stainless Steel AF-LD C C22 Hastelloy AF-PC-001/2/3/4/5 Flange Type Designation Code

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Crispin Valves Operating Guide. Crispin

Filtration Solutions. Cover subheadline. Engineered for performance and value in a variety of applications.

Hayward FLT Series Cartridge Filters. Features. Webster In-Tank Filtration Systems

LIQUID MEASUREMENT STATION DESIGN Class No

Table Of Contents. 1 Tel Fax Toll Free Tel Toll Free Fax

Transportation Products

Selection Guide Ultipleat High Flow Filter System

* Contact your sales representative for compliance to NACE MR or later requirements.

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

Check Valve MODEL. Schematic Diagram. Product Dimensions Data:

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

WARCO CHEMAG SERIES GH FILTERS

Filtomat M100/MG Filters

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

Filter & Strainer. The primary difference between filters and strainers is in the size of the particulates they are removing.

8L SERIES THREE SCREW PUMPS

Series Split Coupled Vertical In-Line Pumps. File no.: 43.10in Date: august 14, 2013 Supersedes: 43.10in Date:

Check List for Optimal Filter Performance

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

PWA-IL B73.2 IN-LINE

AIRPRO MAX AIR VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

Transcription:

TABLE OF CONTENTS AUTOMATIC FILTER & STRAINER SELECTION AUTOMATIC FILTER & STRAINER SELECTION PG. 3 FI SERIES SINGLE BAG FILTER HOUSINGS PG. 4 FI MULTI BAG FILTER HOUSINGS PG. 6 MODEL CS SIMPLEX STRAINERS VESSELS PG. 8 All units available in Carbon Steel, Stainless and Alloys. Dimensions are general, all information to be confirmed with design drawing. MODEL CD DUPLEX STRAINER VESSELS PG. MODEL ACM SELF-CLEANING AUTOMATIC STRAINER 4 18 PG. 12 MODEL ACS AUTOMATIC STRAINER 20 60 PG. 14 AUTOMATIC FILTER MODEL FAFI & FAFX PG. 20 STRAINER SELECTION CHART Degree of Filtration Pipeline Pressure Limits Pipeline Temperature Limits Pressure Temperature Vibration and Shock Corrosion Screen Opening Size Strainer Rating Material of Construction Flow May Be Interrupted Manual Basket Cleaning Simplex Flow May Not Be Interrupted Manual Basket Cleaning Duplex Type of Strainer Flow May Not Be Interrupted Automatic Basket Cleaning Self- Cleaning Pipeline Size Allowable Pressure Drop Size of Strainer 2 RAM LIQUID FILTRATION PRODUCT CATALOGUE 3

FI SERIES SINGLE BAG FILTER HOUSINGS FI MULTI BAG FILTER HOUSINGS RAM filter bag vessels are designed for industrial service. Single bag units are ideal for batch service or when flow interruption is possible. Four standard sized vessels handle various rates of flow and service. Industry standard filter bag sizes of LFB1, LFB2, P1S and P2S are used and also available from RAM Liquid Filtration. Consult the filter model table to determine applicable housing size based on flow rate. The RAM duplex model FI-400 is suitable for a maximum flow rate of 360 GPM, above this see multi-filter housings. With any of RAM s single bag unit designs, manifolds can be added to accommodate two or more housings. Manifolding of two or more units allows for continuous flow while one of the bag chambers is taken off line for filter change out. All vessels are equipped with quick opening covers to facilitate quick and seamless bag change out. Housings come standard with # wire mesh basket to support the filter bag. Housings are designed to produce a low pressure drop and provide the greatest efficiency and life of filter bags. SPECIFICATIONS: Quick opening hinged cover with handle Carbon steel, 304L/316L stainless steel All closure hardware Vent and gauge connections Legs or mounting bracket EPDM or BUNA N seals OPTIONS: Displacement float Alternate material of construction Magnetic post inserts Viton or teflon seals Polished finish for clean service Multi bag housings provide the optimal solution for high flow rates or heavier solid load. Each multi bag housing contains a series of # wire mesh baskets to support individual filter bags. The wire mesh basket offers tremendous integrity while providing the highest open area keeping pressure loss to a minimum. Typical applications include cooling water, plant effluents and many high volume liquid products. Not limited with filter area the multi bag housing is ideal for both heavy solid load applications and higher viscosity liquids. SPECIFICATIONS: Quick opening cover with lifting davit Carbon steel, 304L/316L stainless steel All closure hardware Vent and gauge connections Legs or mounting saddle EPDM or BUNA N seals OPTIONS: Displacement floats Alternate material of construction Magnetic post inserts Viton or teflon seals Wedge-wire baskets FILTER MATERIAL COMPATIBILITY For recommendations on which bag or filter housing material to use, contact RAM Liquid Filtration. FLOW RATE PRESSURE DROP DATA For complete technical data or pressure drop and how to size RAM Bag Filters, contact RAM Liquid Filtration. Information for sales reference only is subject to change without notice. 4 RAM LIQUID FILTRATION PRODUCT CATALOGUE 5

FI MULTI BAG FILTER HOUSINGS FI MUTLI BAG DRAWINGS FLOW RATE FOR NO. 1 SIZE FILTER BAGS AT A GIVEN VISCOSITY AT 1.0 PSI P TO USE THE CHART 1. Select micron rated bags at bottom of chart. 2. Follow the vertical line up until it intersects with the selected viscosity in centipoise. 3. Cross at right angles to left hand ordinate, which will indicate the flow rate at 1 psi pressure drop. 4. When centipoise lines run off at 80 gpm, DP is less than 1 psi pressure drop. NOTE: (A) For flow rates higher than chart - divide desired flow by flow given in chart to obtain resultant DP. (B) For #2 size bags - multiply results by 2. (C) For LFB-1 size bags - divide results by 4. (D) For LFB-2 size bags - divide results by 2. CONVERSION FORMULA Viscosity Units x Factor* x Specific Gravity / 5.62 = Absolute Viscosity (centipoises) VISCOSITY UNITS @ 70 F FACTOR Saybolt Furol.0 Redwood Standard 1.095 Redwood Admiralty.87 Engler 34.5 Parlin Cup #15 98.2 Parlin Cup #2 187.0 Ford Cup #4 17.4 MacMichael 1.92 Demmler # 146.0 Demmler # 14.6 Stormer (approx.) 13 Staybolt Seconds Universal 1.0 *The Conversion Formula is approximately valid when the numerator is greater than 250. For other values, consult Chemical Handbook. Flow Rate (gpm/bag/1.0 P.S.I.) 80 50 30 5 3 1 0.5 0.3 0.1 1 3 1.0 PSI P 20 30 40 50 60 0 200 400 600 5 30 50 Bag Micron Rating 0 Values in the graph are used as a reference only. 300 500 800 00 1500 2000 4000 6000 8000 000 FILTER MATERIAL COMPATIBILITY For recommendations on which bag or filter housing material to use contact us at: 1.844.726.3458 or info@ramliquidfiltration.com GA1 FLOW RATE PRESSURE DROP DATA Contact us for complete technical data or pressure drop and how to size RAM bag filters. Information for sales reference only is subject to change without notice. Model # of Bag Size Inlet / Recommended Dimensional A B C D E F G&H I J Filter Model # of Bag Code Size Outlet Inlet Size / Recommended Max Flow Rate Dimensional Drawing A B C D E F G&H I J Filter Bags Code Outlet Size Max Flow Rate Drawing FI- 25 Bags 1 LFB- 1 1" 25 GA 1 1/2" 3/4" 5 1/2" 6 1/4" 4 1/2" * * * * FI- 25 FI- 50 1 LFB- 1 LFB- 2 1 1" 1/2" 25 50 GA 1 1/2" 16 3/4" 1/2" 511" 1/2" 67 1/4" 1/2" 4 1/2" * * * * FI- 0 FI- 50 1 LFB- 2 P1S 1 1/2" 50 80 GA 1 16 1/2" 7/8" 1627" 1/2" 1611" 3/4" 713" 1/2" 48 1/2" 5/8" * * * * FI- 0 FI- 200 1 P1S P2S 2" 2" or 3" 160 80 GA 1 16 7/8" 3927" 1/2" 16 29 3/4" 13" 8 5/8" * * * * FI- 200 FI- 400 12 P2S 2" 4" or 3" 160 320 GA 1 16 7/8" 39 1/2" 29 3/4" 13" 8 5/8" * * * * FI- 400 FI- 600 23 P2S To 4" Spec 320 480 GA 1 1669" 7/8" 39 51.5" 1/2" 2919" 3/4" 13" 21" 87.5" 5/8" 26" * 3:06 * 2" * 16.5" * FI- 600 FI- 800 34 P2S To Spec 480 640 GA 12 69" 51.5" 19" 21" 7.5" 8" 26" 3:06 4:08 2" 16.5" FI- 00 FI- 800 45 P2S To Spec 640 800 GA 2 69" 51.5" 19" 21" 8" 26" 4:08 2" 16.5" FI- 00 FI- 1200 56 P2S To Spec 800 960 GA 2 69" 70" 51.5" 52" 19" 20" 21.5" 21" 8" 26" 4:08 6:08 2" 16.5" 18" FI- 1200 FI- 1400 67 P2S To Spec 1120 960 GA 2 70" 71" 52.5" 52" 20" 21" 21.5" 22" 8" 26" 28" 6:08 2" 18" 20" FI- 1400 FI- 1600 78 P2S To Spec 1120 1280 GA 2 71" 73" 52.5" 53.5" 22.5" 21" 22" 23" 9.5" 8" 28" 30" 6:08 8: 2" 20" 22" FI- 1600 FI- 1800 89 P2S To Spec 1280 1440 GA 2 73" 75" 53.5" 54.5" 22.5" 24.5" 23" 24" 9.5" 30" 32" 8: 2" 23.5" 22" FI- 1800 FI- 2000 9 P2S To Spec 1440 1600 GA 2 75" 54.5" 24.5" 24" 9.5" 32" 34" 8: 2" 23.5" 25" FI- 2000 FI- 2200 11 P2S To Spec 1600 1760 GA 2 75" 77" 54.5" 55" 24.5" 27.5" 24.5" 24" 9.5" 34" 38" 8: 2" 25.5" 25" FI- 2200 FI- 2400 11 12 P2S To Spec 1760 1920 GA 2 77" 55" 27.5" 24.5" 9.5" 38" 40" 8: 2" 25.5" 27" FI- 2400 FI- 2600 12 13 P2S To Spec 1920 2080 GA 2 77" 83" 60.5" 55" 27.5" 28" 24.5" 27.5" 9.5" 11" 40" 42" 8: 2" 27" FI- 2600 FI- 2800 13 14 P2S To Spec 2080 2240 GA 2 83" 60.5" 28" 27.5" 11" 12" 42" 44" 8: 2" 29.75" 27" FI- 2800 FI- 3000 14 15 P2S To Spec 2240 2400 GA 2 83" 85" 60.5" 61" 28" 27.5" 28" 12" 44" :12 8: 2" 29.75" FI- 3000 FI- 3200 15 16 P2S To Spec 2400 2560 GA 2 85" 61" 28" 28" 12" 44" 46" :12 2" 29.75" 31.25" FI- 3200 FI- 3400 16 17 P2S To Spec 2560 2720 GA 2 85" 61" 28" 28" 12" 46" :12 2" 31.25" FI- 3400 FI- 3600 17 18 P2S To Spec 2720 2880 GA 2 85" 61" 28" 28" 12" 46" :12 2" 31.25" FI- 3600 FI- 3800 18 19 P2S To Spec 2880 3040 GA 2 85" 61" 28" 28" 12" 46" :12 2" 31.25" FI- 3800 FI- 4000 19 20 P2S To Spec 3040 3200 GA 2 85" 61" 28" 28" 12" 13" 46" 48" :12 2" 31.25" FI- 4000 FI- 4200 20 21 P2S To Spec 3200 3360 GA 2 85" 87" 61" 62" 28" 29" 28" 29" 13" 48" :12 :14 2" 31.25" FI- 4200 FI- 4400 21 22 P2S To Spec 3360 3520 GA 2 87" 88" 62.5" 62" 29.5" 29" 29.5" 29" 13" 48" 50" :14 2" 31.25" 34" FI- 4400 FI- 4600 22 23 P2S To Spec 3520 3680 GA 2 88" 62.5" 29.5" 29.5" 13" 50" :14 2" 34" FI- 4600 FI- 4800 23 24 P2S To Spec 3680 3840 GA 2 88" 89" 62.5" 29.5" 29.5" 13" 50" 52" :14 2" 35.5" 34" FI- 4800 FI- 5000 24 25 P2S To Spec 3840 4000 GA 2 89" 92" 62.5" 64" 29.5" 36" 29.5" 32" 13" 52" 54" :14 2" 35.5" 36" FI- 5000 25 P2S To Spec 4000 GA 2 92" 64" 36" 32" 13" 54" :14 2" 36" GA2 Dimensions are general, all information to be confirmed with design drawing. 6 RAM LIQUID FILTRATION PRODUCT CATALOGUE 7

MODEL CS SIMPLEX STRAINER VESSELS MODEL CS SIMPLEX STRAINER VESSELS RAM Liquid Filtration model CS is a fabricated single element strainer vessel. Inlet and outlet connections are on the same plane allowing for in-line pipe installation. Designed to be taken offline for basket clean out the CS is ideal for batch operations. The CS can handle high solid loads and higher viscosity liquids than smaller tee style strainers. The CS is offered in both bolted cover and quick opening designs. At the heart of the CS is a wedge wire straining element. This basket material has the highest open area percentage which allows for improved straining efficiency and longer run times between basket clean outs. SPECIFICATIONS: Inlet and outlet are standard ANSI 150# Carbon steel, 304L/316L stainless steel are standards Legs and/or support saddle OPTIONS: Open bottom basket for manual blow down of basket Off set connections with flat top basket flange Cover lifting davit Special alloy construction High pressure / temperature design Jacketing or heat tracing Special coating and lining available Clearance for Basket Removal G C A Dia Dia D F E H NPT B PRESSURE DROP CURVES 3 4 5 6 8 12 14 16 18 20 24 Pressure Drop P.S.I. 5 3 1 0.5 0.3 CORRECTION FACTORS (BASKET SLOT OPENINGS) (Water) (smaller than 0.032 ). Multiply the pressure drop from the chart by the following factors: 0.1 0 300 500 00 Values in the graph are used as a reference only. 3000 5000 000 Flow Rate (Water) G.P.M. (0.032" Slot Opening and Larger) 30000 50000 0000 VISCOSITY CORRECTION FACTORS 1. Multiply the pressure drop for water by the specific gravity of liquid. 2. Multiply the result by the correction factor for the more viscous liquid. Water has a viscosity of 30 SSU. Dimensions are general, all information to be confirmed with design drawing. 8 RAM LIQUID FILTRATION PRODUCT CATALOGUE 9

MODEL CD DUPLEX STRAINER VESSELS MODEL CD DUPLEX STRAINER VESSELS Model CD is a duplexed arrangement of two individual straining chambers. A valve assembly allows either of the chambers to be isolated for cleaning while the opposite chamber maintains system flow. At the heart of the CD strainer are two wedge wire straining elements. This basket material has the highest open area percentage which allows for improved straining efficiency. STANDARD MATERIALS BODY: Carbon Steel or Stainless Steel BASKET: 304 Stainless Steel VALVES: Butterfly with ductile iron body ductile iron and stainless steel disc A C E B F D SPECIFICATIONS: Inlet and outlet are standard ANSI 150# Standard carbon steel, 304L/316L stainless steel Legs and/or support saddle OPTIONS: Open bottom basket for manual blow down of basket Off set connections with flat top basket flange Cover lifting davit Special alloy construction High pressure / temperature design Jacketing or heat tracing Special coatings and lining are available CORRECTION FACTORS (BASKET SLOT OPENINGS) (Water) (smaller than 0.032 ). Multiply the pressure drop from the chart by the following factors: VISCOSITY CORRECTION FACTORS 1. Multiply the pressure drop for water by the specific gravity of liquid. 2. Multiply the result by the correction factor for the more viscous liquid. G 5 Pressure Drop Curves for CS PRESSURE DROP CURVES 3 4 5 6 8 12 14 16 18 20 24 DIMENSIONAL CHART (APPROX. IN INCHES) Pressure Drop P.S.I. 3 1 0.5 0.3 0.1 0 300 500 00 3000 Flow Rate (Water) G.P.M. (0.032" Slot Opening and Larger) Values in the graph are used as a reference only. Values in the graph are used as a reference only. 5000 000 30000 50000 0000 Dimensions are general, all information to be confirmed with design drawing. RAM LIQUID FILTRATION PRODUCT CATALOGUE 11

MODEL ACM SELF-CLEANING AUTOMATIC STRAINER MODEL ACM SELF-CLEANING AUTOMATIC STRAINER The model ACM self-cleaning strainer provides a highly efficient and reliable means of removing solids from process fluids. A cluster of wedge-wire easy clean straining elements provides positive straining. The exclusive easy clean straining elements are designed with a unique V shape to promote free flow of the incoming liquid and to discourage wedging of any particles. Normal flow is from the inside to the outside of the straining elements and backwashing is accomplished by the reversal of the flow through the elements. The easy clean straining elements are arranged to accumulate debris on the inside. A rotating arm which is vented to the atmosphere isolates each easy clean element for cleaning. Cleaning is accomplished by taking advantage of the system pressure and the use of a small portion of the system flow. When an element is isolated, an effective backwashing action is created without disturbing total flow. Accumulated debris is flushed out of the easy clean element through the backwashing arm and into the drain. The model ACM self-cleaning strainer can be ordered with either continuous backwashing or with the addition of a variety of optional control packages for intermittent backwashing. The model ACM selfcleaning strainers are capable of handling flow rates up to 32,000 USGPM and straining as fine as 0.001 or 25 micron. TYPICAL STRAINER SPECIFICATION Self cleaning strainer Process liquid fluid type Flow rate in GPM Allowable clean pressure drop Operating pressure and temperature Design pressure and temperature Strainer body material of construction Wedge wire element material of construction Slot opening in element/straining size Inlet and outlet connection type and size Electrical requirements (automatic only) STANDARD MATERIALS Standard construction is carbon steel internal epoxy coated and stainless steel, all grades. STANDARD FEATURES Low initial cost Intermittent or continuous backwashing C D E INLET B G F H OUTLET INSPECTION PORT J INLET Stainless steel backwash assembly guided by maintenance-free marine-type cutless bearings Easy clean reverse wound wedge-wire Continuous flow during backwashing Low backwashing flow requirements TEFC Motor 1/220V, single phase, 50/60 Hz OPTIONS Other materials available, including monel and SMO 254 Eductor pump for low pressure service Horizontal configuration A BACKWASH ARM OUTLET DETAIL OF BACKWASH ARM FILTER ELEMENTS BACKWASH SHOE Pressure Drop Curves for ACM PRESSURE DROP CURVE L 5.0 3.0 4 6 8 12 14 16 18 DIMENSIONS (APPROX. 150 PSI) K - DRAIN CONNECTION BACKWASH L M DIA. BACKWASH SHOE Pressure Drop P.S.I. 1.0 0.5 0.3 0.1 30 50 0 300 500 00 Flow Rate (Water) G.P.M. (1/32" Slot Opening) 3000 5000 000 Values in the graph are used as a reference only. Dimensions are general, all information to be confirmed with design drawing. 12 RAM LIQUID FILTRATION PRODUCT CATALOGUE 13

MODEL ACM DESIGN, FEATURES & OPERATION MODEL ACM EASY CLEAN ELEMENTS Model ACM is offered for either horizontal or vertical installation and is available to strain as fine as 0.001 degree of cleaning using RAM s own easy clean elements. The ACM has a larger screen area, providing more filtering surface than any other same size automatic strainer in the marketplace, equating a higher filter open area to inlet area ratio; this allows longer straining cycles and less backwash disposal and electrical usage. The ACM strainer is a fabricated, single body vessel with multiple straining elements. It was designed as a fully automatic self-cleaning strainer. The vessel is available fabricated to ASME Code latest edition and addenda ( U stamped) and National Board Registered, or built in general accordance to ASME Code without code stamp or registration. In Canada, it is available also with CRN registration as required by provincial codes. Inlet and outlet connections are on the sides. The debris laden fluid enters the large lower chamber where it slows down and heavier contaminants settle to the bottom. The fluid flows upward into the straining elements. The fluid then passes through the screen media and exits the strainer through the outlet nozzle. Contaminants gather on the inside of the straining elements. The ACM strainer can perform self-cleaning (backwashing) without interruption of flow. These strainers are designed for liquid service where large quantities of debris must be removed. The ACM strainer uses a motor driven backwash arm to clean the straining elements. The strainer is backwashed by starting the backwash drive and opening the backwash drain valve. This backwashing reverses the flow through each straining element sequentially. The backwash assembly is rotated to cover one element hole in the tube sheet opening a flow path to the outside via the backwash drain. The strainer utilizes system pressure and a percentage of system flow to backwash the straining elements. The controls to accomplish this can be as simple as a toggle switch to start and stop the backwash drive motor and a manual gate or ball valve to control the system backwash flow. The ACM straining element is a cylindrical, reverse wound and resistance welded wedge-wire tube easy clean that is closed at one end and open at the other. Flow during straining is from the inside to the outside of this straining element. Flow direction for backwashing, however, is opposite. The straining elements are constructed for easy replacement. They are held in place with hold down rings or plates, bolted to hold down rods. The backwash arms provide a flow path for the debris collected and the fluid to dislodge the debris during the backwash cycle. The backwash arm directs the dirty fluid to a drain or alternate collection device at atmospheric pressure outside of the strainer. The arm is slowly rotated to allow each straining element to be backwashed during a revolution. Each straining element is isolated by a backwash shoe. The backwash drive system converts the high rotational speed motion of the electric motor to a low rotational speed so as to more effectively backwash the straining element. A shear pin protects the gear reducer, shafting and backwash arm. The backwash system consists of the backwash arms, the backwash shoes and piping that allows the backwash fluid to exit the strainer to an open or low pressure dirty outlet connection. RAM wedge-wire screens are designed to give maximum open area and deliver top performance in any screening application. Every step of production from raw material, wire shaping, screen winding to finished product is done under the same roof, ensuring the quality of the most vital part of any liquid or solid separation strainer filter element. The easy clean straining elements manufactured by RAM are available in reverse wrapped configuration from 0.001 (25 micron) to 0.500 (12,500 micron). RAM easy clean straining elements are designed to give maximum open area and to deliver top performance in any straining or filtering application. Easy clean elements discourage wedging of particles by helical wrapping of vertical rods with a V shaped profile wire. All internal vertical rods are welded to the surface wire at every intersection. The vertical rods being rigidly welded give a smooth unobstructed surface and do not impede the free flow of materials across the easy clean element. This forms a continuous slot which limits the contact of particles to two points in the screen slot and prevents plugging and avoids the stapling effect inherent with other filter media. In this way, the optimum efficiency is assured by maintaining the maximum effective flow area. OPTIONAL CONTROLS A) NEMA 4 (water and dust tight) control box, complete with solid state adjustable timers Backwash drive motor starter Indicator lights to indicate power on and unit flushing H.O.A. (Hands-Off-Auto) selector switch, permits changing from normal intermittent (differential operation) to continuous back-flushing Internally adjustable backwash timer for manual back-flush cycle start, recycle timer Differential pressure switch Full port ball valve complete with actuator, electric actuation B) Same as A) except the NEMA 4 control box is supplied with an input supply transformer for use at 220-480V, single phase, 50/60 Hz. C) Other as specified by specification or customer (example; control boxes NEMA 4X, 7, or 9, external alarm connection, pneumatic actuation, special wiring, specific brand components). MODEL ACM CONTROL SYSTEMS Every ACM strainer is shipped completely assembled, ready to operate. A single 1/3 H.P. motor drives the backwash mechanism of the largest strainer size. The automatic backwash controls (if required) actuate the backwash cycle. RAM automatic controls are engineered and designed to allow for optimal performance and ease of operation. They are factory set and field adjustable so as to provide for a minimal loss of backwash liquid and provide total cleaning of the easy clean elements. Where the loss of backwash liquid or solids is critical, RAM provides the model ACM. APPLICATION AND INDUSTRIAL USES ACM strainers are designed for removal of suspended particulate from all types of liquids, used in practically all industries for quenching, lubrication, spraying, cooling, descaling, pump, valve, heat exchanger and spray nozzle protection. Liquids filtered include well/lake, river, cooling tower or sea (salt water) to white water, black liquor (pulp and paper mills), chemicals, sewage and lubricating oils. 14 RAM LIQUID FILTRATION PRODUCT CATALOGUE 15

MODEL ACS AUTOMATIC STRAINER MODEL ACS AUTOMATIC STRAINER 5.0 The model ACS is a custom fabricated selfcleaning strainer designed for continuous backflush operation. Featuring a fabricated backwash arm and a single, replaceable element wedge-wire basket -both of stainless steel construction the model ACS is designed to be unattended for extended periods of time. The large amount of open area allows intermittent back-flush operation, thereby minimizing both operating costs and backwash effluent. The wedge-wire element features a reverse groove design that prevents lodging of debris in the element and creates a vortex during back-flush for a more efficient back-flush operation. The model ACS can be constructed from a variety of materials - from Pressure Drop Curves for ACS PRESSURE DROP CURVES 20 carbon steel to stainless steel to exotic alloys - or can be coated internally with fusion bonded epoxy finish, allowing it to handle any fluid. For a truly customizable strainer that can be designed for any application or budget, the ACS is the only choice. OPTIONAL AND STANDARD FEATURES Standard construction is carbon steel epoxy lined, available in stainless steel all grades, monel, SMO 254. Elements are standard as 304 stainless steel. All other materials are available. Standard unit complete with gear reducer and drive motor for continuous back-flushing. The standard TEFC motor is 1/220V, single phase, 50/60 Hz. 24 30 36 42 D - MIN SPACE HEAD/BASKET REMOVAL MOTOR WITH GEAR REDUCER PRESSURE CONNECTIONS B OUTLET 4X DIA. 4X DIA. 4X 45 DEG. 4X K THRU 45 DEG. K THRU INLET 4X J 4X J SECTION A-A SECTION A-A C H 4X L X L PAD 4X L X L PAD BACKWASH E OPTIONAL SPACE FOR CONROL PANEL & DIFF. PRESSURE SWITCH MOUNTING F INSPECTION PORT 3.0 DRAIN / BLOWDOWN Pressure Drop P.S.I. 1.0 0.5 0.3 OUTLET DRAIN DIMENSIONS (APPROX.) 150PSIG A A A 0.1 00 3000 5000 000 Flow Rate (Water) G.P.M. (1/8" Slot) 30000 50000 0000 Values in the graph are used as a reference only. Dimensions are general, all information to be confirmed with design drawing. 16 RAM LIQUID FILTRATION PRODUCT CATALOGUE 17

MODEL ACS DESIGN, FEATURES & OPERATION MODEL ACS EASY CLEAN ELEMENTS RAM model ACS strainers are offered in capacities to 0,000 gallons per minute. The strainers are offered for vertical installation and available to 0.001 degree of cleaning using easy clean elements. RAM model ACS strainer is a fabricated single body vessel with a single straining element. Designed as a fully automatic self-cleaning strainer. The vessel is available fabricated to ASME Code latest edition and addenda ( U stamped) and National Board Registered, or built in general accordance to ASME Code without code stamp or registration. In Canada, it is available also with CRN registration as required by province. Inlet and outlet connections are on the sides. The debris laden fluid enters the large lower chamber where it slows down and contaminants settle to the bottom. The fluid flows upward into the straining basket. The fluid then passes through the easy clean element and exits the strainer through the outlet nozzle. Contaminants gather on the inside of the basket in pockets created by the baskets vertical spacer rods. The backwash arms provide a flow path for the debris collected and the fluid to dislodge the debris during the backwash cycle. The backwash arms direct the dirty fluid to an open pit or tank at atmospheric pressure outside of the strainer. The arms rotate slowly to allow each section of the basket to be backwashed in turn. The backwash drive system converts the high rotational speed of the electric motor to a low rotational speed so as to more effectively backwash the straining basket. A shear pin protects the gear reducer, shafting and backwash arm from serious damage. The ACS strainer can perform self-cleaning (backwashing) without interruption of flow. These strainers are designed primarily for liquid service where large quantities of debris must be removed. RAM model ACS strainer uses a motor driven backwash arm to clean the strainer basket. A hollow shaft with two diametrically opposite arms rotates inside the basket and in turn blocks off a section of the basket. The two arms are open to the basket and to the atmosphere through the hollow shaft and backwash piping. Reversal of flow causes the debris and other contaminants to flow out through the backwash arm and out through a control valve to the drain. The strainer can be set for continuous backwash or automatic intermittent backwash operation. The backwash arm is driven by a standard motor through a reduction gear. Access opening is provided for inspection and removal of large pieces of debris accumulated at the bottom of the strainer. RAM model ACS easy clean element is cylindrical, made of reverse formed and resistance welded wedge-wires. Flow during straining is from the inside to the outside. Flow direction for backwashing, however, is opposite. The basket is a fabricated cage assembly that consists of a top, bottom and middle spacer ring that are fit and welded to the vertical spacer rods. The screen elements are constructed for easy replacement; they are bolted around the cage assembly in equal segments. The easy clean straining elements are available in reverse formed configuration to 0.001 and are designed to give maximum open area and to deliver top performance in any straining application. OPTIONAL CONTROLS A) NEMA 4 (water and dust tight) control box, complete with solid state adjustable timers. Backwash drive motor starter Indicator lights to indicate Power on and unit Flushing H.D.A. (Hands-Off-Auto) selector switch, permits changing from normal intermittent (differential operation) to continuous back-flushing Internally adjustable backwash timer for manual back-flush cycle start, recycle timer. Differential pressure switch Full port ball valve complete with actuator, electric actuation B) Same as A) except the NEMA 4 control box is supplied with an input supply transformer for use at 220-480V, single phase, 50/60 Hz. C) Other as specified by specification or customer (example: control boxes NEMA 4X, 7, or 9, external alarm connection, pneumatic actuation, special wiring, specific brand components). ACS CONTROL SYSTEMS Every ACS strainer is shipped completely assembled, ready to operate. A single 1/3 H.P. motor drives the backwash mechanism of the largest strainer size. The automatic backwash controls (if required) actuate the backwash cycle. RAM Liquid Filtration automatic controls are engineered and designed to allow for optimal performance and ease of operation. They are factory set and field adjustable so as to provide for a minimal loss of backwash liquid and provide total cleaning of the east clean element. APPLICATION AND INDUSTRIAL USES ACS strainers are designed for removal of suspended particulate from all types of liquids, used in practically all industries for quenching, lubrication, spraying, cooling, descaling, pump, valve, heat exchanger and spray nozzle protection. Liquids filtered include well/lake, river, cooling tower or sea (salt water) to white water, black liquor (pulp and paper mills), chemicals, acids, sewage and lubricating oils. 18 RAM LIQUID FILTRATION PRODUCT CATALOGUE 19

MODEL FAFI & FAFX AUTOMATIC FILTER MODEL FAFI & FAFX AUTOMATIC FILTER DESIGN RAM modular filter systems consist of three (3) or more single filter units valved in parallel to common headers. The advantage of this type of filter system is that each filter unit can be individually backwashed either automatically, manually, or intermittently while the others remain on stream. PRINCIPLE OF OPERATION The filter works by unfiltered liquid entering the inlet header. It flows through the valve and upward through the filter media from outside to inside. The filtered liquid discharges through the outlet header at the top of the unit. BACKWASHING With the direction of flow (outside to inside), the solids build up on the outside of the filter elements. This makes the element very easy to backwash. Backwashing takes place when the differential pressure between the inlet header and outlet header reaches a preset level. At this point, the filter control module triggers a backwash sequence. In turn, each filter is cleaned while the other units remain on stream. INTERNAL OR EXTERNAL BACKWASHING Internal backwashing is when the filtered liquid is used for backwashing. External backwashing is when a secondary liquid is used. Internal backwashing is usually recommended where the process liquid is free flowing, inexpensive and plentiful. External backwashing is highly recommended when the operating pressure is too low for effective backwashing, or when it is not economically feasible. STANDARD FEATURES Positive basket seal to prevent by-pass Manual or fully automatic self cleaning Continuous flow even white backwashing Maintenance on each filter unit can be performed without shutting down the system Quick opening cover for easy access to filter media Reusable filter elements FLOW DIAGRAM FOR INDIVIDUAL CHAMBER EXTERNAL BACK-WASHING SYSTEM INTERNAL BACK-WASHING SYSTEM 20 RAM LIQUID FILTRATION PRODUCT CATALOGUE 21

MODEL FAFI & FAFX AUTOMATIC FILTER MODEL FAFI & FAFX AUTOMATIC FILTER The continuous wedge-shaped slots in the element effectively separates solids from the fluid passing through the unit. The unique RAM wedge design of the element offers high strength, high open area and less clogging than other types of elements. These 316 stainless steel screens are available from 0.001 to 0.25 slot size. FABRIC RAM fabric media are woven from synthetic fibers and are chemically compatible with most liquids. Fabric media offers an excellent means of filtering liquids with retention levels down to nominal 5 microns. These synthetic fibers also have excellent solids release characteristics for easy cleaning. WIRE MESH Woven wire mesh screens provide good solids release characteristic. The wire mesh screens are made of type 316 stainless steel and wedge-wire inner backing is used to give it support. Wire mesh sizes are available from 1 micron to 0 micron. HOUSING MATERIAL: Standard construction is carbon steel internal epoxy coated and stainless steel, all grades. GASKETS: Available in buna-n, ethylene propylene (EPR), viton, silicone or teflon. FILTER MEDIA: Stainless steel, polyester or polypropylene. DESIGN PRESSURE: 150 psi and 300 psi standard construction. TEMPERATURE LIMITS: Temperature limits will vary depending on the gasket and screen material. FLOW RATE: Max. flow rate per element is 150 GPM. EXAMPLE: Determine filter size for 500 gpm using wedge-wire element with 0.006 slot. 1. From Table 1 determine sizing factor. (which is 2.1). 2. Multiply the flow by the sizing factor to give us the factored flow. (ie. 500 x 2.1=1,050 factored flow). 3. From Chart 1 determine the number of elements needed. In our example for factored flow of 50, the number of elements needed is 5. 4. Table 2 gives the model # needed for either internal or external backwashing units. 5. Make sure that maximum flow rate per element is not exceeded. Divide the flow rate by the number of elements. The result should not exceed 0 gpm (500/5=0 gpm). FLOW FACTOR (TABLE 1) *Above sizing factor is based on filtering water. Dimensions are general, all information to be confirmed with design drawing. FLOW FACTOR (TABLE 2) SIZING CHART 26 24 22 20 18 16 14 12 8 6 4 2 0 0 2 4 6 8 12 14 16 Number of Elements Required 18 20 22 24 26 28 30 32 34 Units placed back-to-back are half the Length L. Dimensions are general, all information to be confirmed with design drawing. Factored Flow (GPM) X 0 22 RAM LIQUID FILTRATION PRODUCT CATALOGUE 23

RAM LIQUID FILTRATION 1311 Kerrisdale Boulevard, Newmarket, ON L3Y 8Z8 www.ramliquidfiltration.com