Battery Boxes Series 8316

Similar documents
Ex UPS standard Series 8265

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Plug and Socket Devices SolConeX 16 A Series 8570

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Load disconnect switch Series 8146/5-V11

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Luminaire with LED Series EXLUX 6409/1

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Linear luminaire with LED Series EXLUX 6002

LED Linear Luminaire Series EXLUX 6402

Position Switches Series 8070/2

Control switch/load disconnect switch Series 8008

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Linear Luminaire with LED Series EXLUX 6002

Load and Motor Switches, Load-Break Switches Series 8544

Linear Luminaire with LED Series EXLUX 6402/2

Safety Switches Series 8537

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Position Switches Series 8060/2

Position Switches Series 8074/2

Load and Motor Switches, Load-Break Switches Series 8549

Metal Position Switch Series 8074

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Load and Motor Switches, Load-Break Switches Series 8544

Compact Sheet-Steel Light Fittings Series 6114/1

Terminal Boxes Series 8125

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Floodlight LED Series 6125

11 Control Panels, Distribution Panels and Components

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Portable Lamps Series HS6145, HSL145

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Floodlight LED Series 6525

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Floodlight LED Series 6525

Tubular Light Fitting with LED Series 6036

Floodlight Series 6521/4

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Terminal Boxes Series 8125

Control Buttons / Switches for Panel Mounting Series 8003

10 Load and Motor Switchgear

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

7 Lighting Technology

Floodlight Series 6121

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Control Buttons Series 8082

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Sheet-Steel Light Fittings Series 6014 / 6414

Main current switches >180 A are realized in metal enclosures. Internationally approved.

EX-REPAIR AND MAINTENANCE RECEPTACLES

2/2- and 3/2-way solenoid valve for aggressive fluids

Sheet Steel Emergency Light Fitting Series 6018

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Terminal Boxes Series 8252/1

Control Device System NEC Series ConSig 8040

7 Lighting Technology

I Ex-safety switches I

I Ex-safety switches I

Compact Sheet-Steel Light Fittings Series 6114

Control and Terminal Box Type A21-**-*****

Terminal Boxes Series 8146

International approvals.

2/2 Solenoid Cartridge Valve, Size 6

I Ex-Safety switches I

Terminal Boxes in Stainless Steel SLS**.T

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

7 Lighting Technology

Junction box for EKL light

Tank Inspection Lights Series 6122

A good connection. International approvals.

Unused flameproof threads for cable glands have to be closed with certified plugs.

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

HTSB system System overview

9 Control Equipment. Control Unit System Series ConSig 8040

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

7 Lighting Technology

Industrial Batteries Network Power Powerfit S500 High energy density for maximum security. Specifications

YFC. Limit switch. Ex d. 24 operating head types

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

7 Lighting Technology

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Operating Instructions

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

M-0. M-0... series control, monitoring and signalling devices. Ex e

Internationally approved.

Operating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom

Transcription:

www.stahl.de > Back-up power supply > Maintenance-free batteries > Low self-discharge > Extremely low gas emissions > Electrolyte-tight > No acid surface coating > Protection against total disch arge > Leak-proof > Stable cycle and durability > Long service life > Buffer for irregular charging > Reliable continuous current output 10994E00 The battery box of is used as a back-up power supply unit in hazardous areas. The gases formed during charging recombine to form water in the closed battery system within the cells. This ensures extremely clean and safe handling since neither gases nor acid mist are emitted to the outside. ATEX Zone 0 1 2 20 21 22 For use in x x WebCode 83A Applications Low Voltage Systems /1

Selection Table Version voltage Rated operational current capacity Charging current Charging voltage Order number Ah Modules 12 V 2 A 2 0.2 A 13.8 V 83/22-12-020 10 A 10 1.0 A 13.8 V 83/22-12-100 Complete units with terminal compartment 25 A 25 2.5 A 13.8 V 83/22-12-0250-1-086 40 A 40 4.0 A 13.8 V 83/22-12-0400-1-086 63 A 60 6.0 A 13.8 V 83/22-12-0600-1-086 24 V 2 A 2 0.2 A 2.6 V 83/22-24-020 10 A 10 1.0 A 2.6 V 83/22-24-100 25 A 25 2.5 A 2.6 V 83/22-24-250-000 40 A 40 4.0 A 2.6 V 83/22-24-400-000 63 A 60 6.0 A 2.6 V 83/22-24-600-000 12 V 2 A 2 0.2 A 13.8 V 83/22-12-020-000 10 A 10 1.0 A 13.8 V 83/22-12-100-000 25 A 25 2.5 A 13.8 V 83/22-12-250-000 40 A 40 4.0 A 13.8 V 83/22-12-400-000 63 A 60 6.0 A 13.8 V 83/22-12-600-000 24 V 2 A 2 0.2 A 2.6 V 83/22-24-020-000 10 A 10 1.0 A 2.6 V 83/22-24-100-000 Explosion Protection Global (IECEx) Gas IECEx DEK 13.0081X Ex e IIC T6 Gb Europe (ATEX) Gas Certifications and certificates Certificates 25 A 25 2.5 A 2.6 V 83/22-24-250-000 40 A 40 4.0 A 2.6 V 83/22-24-400-000 63 A 60 6.0 A 2.6 V 83/22-24-600-000 KEMA 04ATEX 223 X E II 2 G Ex e II T6 Gb IECEx, ATEX /2 Applications Low Voltage Systems

Technical Data Electrical data Terminal compartment Fuse boxes Rated operational voltage Rated current Batteries Ambient conditions Ambient temperature type Fuse with characteristic Fuse type 83/22-..-020 T 2.0 A 8560/51-422 83/22-12-100 B 10.0 A 8562/51-1010-100 83/22-24-100 B 10.0 A 8562/52-2010-100 83/22-12-250 B 25.0 A 8562/51-1010-250 83/22-24-250 B 25.0 A 8562/52-2010-250 83/22-12-400 B 40.0 A 8562/51-1010-400 83/22-24-400 B 40.0 A 8562/52-2010-400 83/22-..-600 gg 63.0 A 8561/02-12 2.0... 24 V DC type voltage Capacity 83/22-12-020 12 V 2 Ah 83/22-12-100 12 V 10 Ah 83/22-12-250 12 V 25 Ah 83/22-12-400 12 V 40 Ah 83/22-12-600 12 V 60 Ah 83/22-24-020 24 V 2 Ah 83/22-24-100 24 V 10 Ah 83/22-24-250 24 V 25 Ah 83/22-24-400 24 V 40 Ah 83/22-24-600 24 V 60 Ah type A 512/... S2 10 S 25 G5 40 A 60 A Nominal voltage V 12 Nominal capacitance C 20 1.5 V/Z, Ah 2.0 10.0 25.0 40.0 60.0 20 C Discharge current I 20 A 0.050 0.50 1.25 2.00 3.00 Maximum load 1 approx. 40 80 200 400 400 A Internal resistance according to mω 12.0 66.0 21.3 11.6 6.6 IEC 896-2 Short-circuit current according to A 3 189 583 1069 188 IEC 896-2 For planning: Max. discharge current A 40 80 200 400 400 Fuse protection with I n A 2 10 25 40 63 1 with corresponding matching contacts Charging according to IEC/EN 6009- Standard device: - 20... + 40 C Temperature range for charging: 0... + 40 C Mechanical data Degree of protection IP23 according to IEC/EN 60529 Terminal compartment Applications Low Voltage Systems /3

Technical Data Connection cross-section Cable glands type Max. cross-section for connection 83/22-..-020 6 mm 2 83/22-..-100 6 mm 2 83/22-..-250 10 mm 2 83/22-..-400 mm 2 83/22-..-600 35 mm 2 type Cable glands Cable dia. range 83/22-..-020 83/22-..-100 83/22-..-250 83/22-..-400 83/22-..-600 1 x M25 1 x M20 1 x stopping plug M25 1 x M32 1 x M20 1 x stopping plug M32 mm... 1 mm 6 mm... 13 mm 13 mm... 21 mm 6 mm... 13 mm boxes Material Glass fibre reinforced polyester resin Cheese-head screws M6 x 28 Available versions The battery box is available in the following versions: type Design (i.s. = in series) Ventilation types openings 83/22-12-020 1 x 12 V battery 2 Ah 1 x size 1 1 x A512/2 S 83/22-12-100 1 x 12 V battery 10 Ah 1 x size 1 1 x A512/10 S 83/22-12-250 1 x 12 V battery 25 Ah 2 x size 2 1 x A512/25 G5 83/22-12-400 1 x 12 V battery 40 Ah 2 x size 2 1 x A512/40 A 83/22-12-600 1 x 12 V battery 60 Ah 2 x size 2 1 x A512/60 A 83/22-24-020 2 x 12 V battery i.s. 2 Ah 1 x size 1 2 x A512/2 S 83/22-24-100 2 x 12 V battery i.s. 10 Ah 2 x size 2 2 x A512/10 S 83/22-24-250 2 x 12 V battery i.s. 25 Ah 4 x size 2 2 x A512/25 G5 83/22-24-400 1 x 12 V battery 40 Ah each 2 x size 2 each 1 x A512/40 A each 83/22-24-600 1 x 12 V battery 60 Ah each 2 x size 2 each 1 x A512/60 A each Batteries Material A512/2 S A512/10 S A512/25 G5 A512/40 A A512/60 A A512/2 S, A512/10 S A512/24 G5 A512/40 A, A512/60 A UP-VW1220 SB12/60 A ABS PP mit verlötetem Steckkabelschuh 5 Nm 8 Nm ABS mit verlötetem Steckkabelschuh 8 Nm Service life A512 Jahre Design Life bei einer Umgebungstemperatur von 20 C (80% Restkapazität von C 20) UP-VW1220 3Jahre bi 25 C oder 5 Jahre bei 20 C SB 12/60 2 Jahre bei 20 C /4 Applications Low Voltage Systems

Accessories and Spare Parts Designation Illustration Description Art. no. Weight kg Batteries A512 / 2 S 125059 1.000 A512 / 10 S 125060 4.000 A512 / 25G5 12506 9.650 Cable glands of moulded material, series 81 A512 / 40 A 125061 14.600 A512 / 60 A 12505 21.00 81/5-M20-13 50 pieces 138454 0.600 02055E00 81/5-M25-1 50 pieces 138456 1.000 81/5-M 25-96 50 pieces 13844 1.000 81/5-M 32-21 81/5-M 32-9 25 pieces 25 pieces 138458 0.89 13848 0.910 Counter nut To fasten the cable glands at the through drilling 05865E00 For cable glands Type Thread size Packaging unit Brass, nickelplated Brass, nickelplated M25 x 1.5 50 M25 x 1.5 50 138389 0.241 138395 0.348 Fuses Brass, nickelplated 8560/51, 250 V UC M32 x 1.5 25 138401 0.26 I N [A] Packaging units [pieces] 0536E00 2.0 1 piece 149112 0.035 2.0 5 1494 0.210 Back-up fuse 8561/02-12 63 A 111269 0.051 052E00 Applications Low Voltage Systems /5

8562/51-LS 8562/51-LS 8562/51-LS Boxes Complete units with terminal compartment 10 51,5 8146/.03 53 118 8146/.051 Enclosure type 8146/5000-6-12-020 12204E01 34 53 F 8146/.03 8146/.03 Enclosure type 8146/5000-6-12-100 51,5 322,5 53 12205E01 8146/.085 8146/.03 Enclosure type 8146/5000-6-12-250 51,5 322,5 53 12206E01 8146/.085 8146/.03 1220E01 /6 Applications Low Voltage Systems

8561/02 P 8562/52-LS CODE_51 8562/52-LS CODE_51 Boxes Enclosure type 8146/5000-6-12-400 51,5 322,5 53 8146/.085 8146/.03 Enclosure type 8146/5000-6-12-600 10 12208E01 51,5 53 118 8146/.03 F2 8146/.051 Enclosure type 8146/5000-6-24-020 51,5 322,5 53 8146/.085 8146/.03 12209E01 Enclosure type 8146/5000-6-24-100 12210E01 864,1 322,5 53 322,5 53 8146/.086 8146/.086 8146/.03 12211E01 Applications Low Voltage Systems /

8561/02 P 8562/52-LS CODE_51 8561/02 P Boxes Enclosure type 8146/5000-6-24-250 864,1 322,5 53 322,5 53 8146/.086 8146/.086 8146/.03 Enclosure type 8146/5000-6-24-400 864,1 322,5 53 322,5 53 12212E01 F2 8146/.086 8146/.086 8146/.03 Enclosure type 8146/5000-6-24-600 12213E01 boxes 10 ~ 0 9 8146/.03 12V/24Ah A512/2,0S 8146/503 A bottom 06263E00 Enclosure type 8146/503 for battery boxes Types 83/22-12-020 and 83/22-12-100 06264E01 /8 Applications Low Voltage Systems

322.5 8146/5086 ~ 240 9 8146/.085 12V/24 Ah A512/24,0 G5 D bottom 06266E00 0626E01 Enclosure type 8146/5086 for battery boxes Type 83/22-12-250 8146/.086 322.5 ~ 240 9 12V/40Ah A512/40,0A 8146/5086 06266E00 Enclosure type 8146/5086 for battery boxes Types 83/22-12-400 and 83/22-12-600 D bottom 0623E01 10 8146/503 ~ 0 9 8146/.03 12V/24Ah A512/2,0S 12V/24Ah A512/2,0S A bottom 06263E00 0624E01 Enclosure type 8146/503 for battery boxes Type 83/22-24-020 Applications Low Voltage Systems /9

322.5 ~ 0 9 12V/10Ah A512/10,0S 8146/.083 12V/10Ah A512/10,0S 8146/5086 D bottom Enclosure type 8146/5083 for battery boxes Type 83/22-24-100 0625E00 0626E01 322.5 ~ 240 9 8146/.095 12V/24Ah A51224,0 G5 681 8146/5086 629.5 12V/24Ah A51224,0 G5 8146/5086 A bottom Enclosure type 8146/5000 for battery boxes Type 83/22-24-250 0628E00 06286E01 /10 Applications Low Voltage Systems

292 50 ~ 240 894 844 8146/5086 A1 9 8146/.086 12V/40Ah A512/40,0A D bottom A1 8146/.086 12V/40Ah A512/40,0A 8146/5086 A2 D bottom A2 06280E00 06284E01 Enclosure type 8146/5000 for battery boxes Types 83/22-24-400 and 83/22-24-600 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Applications Low Voltage Systems /11