-H- Note. Sub-bases VABP Key features

Similar documents
-H- Note. Sub-bases VABP Key features

Control block VOFA with safety function

Solenoid valves MFHE/Pneumatic valves VLHE

Proportional pressure regulators MPPES

V New VSVA. Solenoid/pneumatic valves, ISO Electrically or pneumatically actuated valves. With internal or external pilot air

Solenoid/pneumatic valves, ISO

Solenoid valves VUVS/valve manifold VTUS, NPT

Solenoid valves VUVS/valve manifold VTUS, NPT

Flow control valves GRO, in-line installation

Solenoid valves VUVB/valve terminals VTUB, NPT

On-off Valves MS-EE, Inch Series Overview

Proportional directional control valves VPWP

Solenoid valves VMPA

Solenoid valves VUVB/valve terminals VTUB

Semi-rotary drives DRVS

Solenoid/pneumatic valves, Tiger Classic

Proportional pressure regulators VPPE

Pneumatic components for high-pressure applications

On-off/soft-start valves MS-EM/EE/DL/DE, MS series

Compact cylinders ADN-S, AEN-S

Feed separators HPVS

Solenoid valves VZWP, servo-controlled

On-off/soft-start valves HE/HEE/HEP/HEL, D series

Proportional pressure regulators VPPX

Vacuum generators Key features

On-off/soft-start valves HE/HEE/HEP/HEL, D series

Pneumatic valves VUWS/valve manifold VTUS

Pneumatic valves VUWS/valve manifold VTUS

Solenoid valves VOVG Product range overview

-V- New. Linear drives DGC Features. 2 Internet:

Valve terminals VTUB-12

Linear drives DGC-HD, with heavy-duty guide

Solenoid valves MHJ, fast-switching valves

Semi-rotary drives DRQ

Twin-piston semi-rotary drives DRRD

Check valves H/HA/HB/HGL

Soft-start and quick exhaust valves MS-SV, MS series

One-way flow control valves GR/GRA, in-line installation

On-off valves MS-EM/EE, MS series, NPT

Hinge cylinders DW Key features

Swivel modules DSM/DSM-B

Solenoid valves VUVG/valve terminals VTUG

Solenoid valves MH2/MH3/MH4, fast-switching valves

Linear drives DGC-K. Festo core product range Covers 80% of your automation tasks

Twin-piston semi-rotary drives DRRD

Standard valves to ISO Product range overview

Solenoid valves VUVG/valve terminals VTUG

Quick availability: selected products from the VUVS series

Quarter turn actuators DFPB

Solenoid valves VZWM-L, NPT

On-off/soft-start valves MS-EM/EE/DL/DE, MS series

-H- Note. Feed separators HPV Key features at a glance. Separation of workpieces in the supply process

Linear/swivel clamp CLR

Valve terminals VTSA/VTSA-F

Standard cylinders DDPC, with measured-value transducer DADE

Quarter turn actuators DFPD

Radial grippers DHRS

Linear actuators DFPI

Compact Cylinders ADN Inch Series, Based on ISO Overview

Slide units SPZ, twin piston

Swivel modules DSMI-B, with integrated angular displacement encoder

Front panel valves SV

Flat cylinders EZH/DZF/DZH

Quarter turn actuators DFPB

Pressure regulators MS-LR/LRB/LRP/LRPB/LRE, MS series

Valve terminals VTSA/VTSA-F, NPT

Parallel grippers HGPL-B, heavy-duty with long stroke

Hinge cylinders DFAW

Branching modules FRM/Distributor blocks FRZ, D series

Vacuum generators OVEM

Guided drives DGRF-C, Clean Design

Valve terminals VTUB-12

Guide axes ELFA, without drive

Stopper cylinders DFST

Radial grippers DHRS

Linear drives DGPL Selection aid

Quarter turn actuators DFPD

Round cylinders DSNU/DSNUP/DSN/ESNU/ESN

-H- Note. Silencers Product range overview. Version Type Connection D1 Push-in connector. For tubing I.D. Push-in sleeve diameter.

Three-point grippers DHDS

Cylinders DSBG to ISO 15552

Solenoid valves VZWM-L

Linear actuators DLP, Copac

Standard cylinders DNCI, with measured-value transducer DADE

Solenoid valves VZWM-L

Standard cylinders DNG/DNGZS, ISO 15552

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

Planar surface gantries EXCH

Linear drives DGPL, with external displacement encoder

Pressure regulators MS-LR/LRB/LRP/LRPB/LRE, MS series

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Metric Series Overview

Order guide for standalone valves VUVS/VUVG

Solenoid valves MH2/MH3/MH4, fast-switching valves

Linear drives DGC Key features

Multi-position cylinders/adapter kits

-U- Type discontinued. -H- Note. Available up until Angle grippers HGWC Key features

Clamping-unit cylinders, standard port pattern

Mini slides SLT/SLS/SLF

Parallel grippers DHPS

FAST Program 2013 Festo Assured Shipping Time

Transcription:

Key features At a glance The sub-base VABP can be used to help realise specific switch-off behaviour when switching off the valve load voltage. It is a single-channel solution for uncoupling the drive from the power valve. 4 switch-off functions are possible. The sub-base is not a safety device, nor is it a complete safety solution. However, it can form part of a safety solution. Features: Compact design Simple installation Suitable for servopneumatic drives Can be attached directly to the proportional directional control valve VPWP Connecting cable for direct connection to the proportional directional control valve VPWP Suitable for cylinders that are controlled by 5/- or 5/3-way valves For ISO valves with spring return and external auxiliary pilot air Extended accessories: ISO solenoid valves with switching position sensing for producing a diagnostic rate 60% The technology in detail Sub-base VABP (example with valves mounted) Pilot air port 3 Function port B 4 Function port A 5 Solenoid valve VSVA, MNH 6 Proportional directional control valve VPWP 7 Mounting screws 5 6 7 3 4 The 4 different single-channel switchoff functions can be configured using function ports 3 (A) and 34 (B): Stopping a movement: blocking De-energising: exhausting Reversing with reduced speed Switching off power: short-circuit VAPB B A -H- Note An application document "Demonstrating VABP protective measures" is available from the Support Portal. Internet: www.festo.com/catalogue/... Subject to change 06/0

Type codes VABP S3 6VG G8 M R3 Series VABP Sub-base Allocation S3 ISO 5407 S ISO 5599 Size 6 Size 6 Size Size Version V Switching variant emergency stop functions Connection type G Pneumatic port G8 G/8 G4 G/4 G38 G3/8 Supply air/exhaust air/pilot air supply/pilot exhaust air Valve positions valve positions Equipment M With valves Electrical connection Without R3 Individual plug M A Individual plug type A 06/0 Subject to change Internet: www.festo.com/catalogue/... 3

Peripherals overview VABP-S3-6VG / VABP-S-VG 8 aa aj 7 8 9 ab 5 ab ab 3 ag ac 4 ad ae af ag ac ad ae af ag ac ad ae af VABP-S-VG bj ai ah ab 6 ba ag ac ad ae af 4 Internet: www.festo.com/catalogue/... Subject to change 06/0

Peripherals overview Accessories See allocation table below Description Page/ Internet 3 4 5 6 Proportional directional control valve VPWP Sub-base VABP 7 Connecting cable NEDV 8 Connecting cable NEBU-M 9 Plug socket MSSD-EB aj aa ab ac ad ae af ag ah ai bj ba Plug socket with cable KMEB Connecting cable NEBU-M8 Push-in fitting QS Blanking plug B Push-in fitting QS Exhaust air flow control valve GRE Silencer UC Push-in fitting QS Solenoid coil MSNG Connecting cable KMC Plug socket MSSD-C Plug NECU 5/3-way proportional directional control valve for applications with Soft Stop and for pneumatic positioning For realising specific switch-off functions 6 Connection of solenoid valve to proportional directional control 5 valve VPWP Connection of solenoid valve to controller. 5 Alternative to 7 Connection of solenoid valve to controller. 5 Alternative to aj Connection of solenoid valve to controller 5 Connection of switching position sensing system to controller 5 For working ports and 4 5 For function ports 3 and 34 4 For realising a switch-off function For function ports 3 and 34 5 For realising a switch-off function For function ports 3 and 34 4 For realising a switch-off function For function ports 3 and 34 4 For realising a switch-off function For pilot air port 4 5 For actuating the solenoid valve 4 Connection of solenoid valve to controller 5 Connection of solenoid valve to controller. Alternative to ai For connecting the solenoid valves to the proportional directional control valve VPWP vpwp 5 5 Allocation table Sub-base Solenoid valve ( 4) Proportional directional control valve 3 VABP-S3-6VG VSVA-B-M5-MZH-A-R5L VPWP-4/-6 4 VABP-S3-6VG VSVA-B-M5-MZ-A-C-APP ) VPWP-4/-6 5 VABP-S-VG VSVA-B-M5-MZD-D-R5L VPWP-8 6 VABP-S-VG MNH-5/-D--FR-S-C VPWP-0 ) Solenoid valve with switching position sensing 06/0 Subject to change Internet: www.festo.com/catalogue/... 5

-M- Flow rate 800 000 l/min -L- Pressure 0 6 bar General technical data Type VABP-S3-6VG VABP-S-VG VABP-S-VG For proportional directional control valve VPWP-4/-6 VPWP-8 VPWP-0 Width [mm] 6 4 54 Pneumatic port Working ports:, 4,, 44 Gx G¼ Gy Pilot air supply: 4 M5 Gx Gx Function ports: 3, 34 Gx Gx G¼ Nominal flow rate [l/min] 800 400 000 Mounting position Any Product weight [g] 668 63 950 With valves [g] 00 480 3400 With solenoid valve 3 4 Valve function 5/ Reset method Mechanical spring Type of control Piloted Pilot air supply External Direction of flow Reversible Switching position sensing Yes Switching element function N/C contact Switching output PNP Nominal width 9 Actuation type Electrical Manual override Without or covered Nominal operating voltage [V] 4 Perm. voltage fluctuations [%] ±0 ±0 5/±0 Allocation table, solenoid valve VSVA-B-M5-MZH-A-R5L VSVA-B-M5-MZ-A-C-APP 3 VSVA-B-M5-MZD-D-R5L 4 MNH-5/-D--FR-S-C 6 Internet: www.festo.com/catalogue/... Subject to change 06/0

Operating and environmental conditions Type VABP-S3-6VG VABP-S-VG VABP-S-VG Operating medium ) Compressed air to ISO 8573-:00 [6:4:4] Operating pressure ) [bar] 0 6 Pilot pressure with valves [bar] 3 8 Ambient temperature [ C] 0 +50 Temperature of medium [ C] 0 +50 ) Note operating range of connected components. Materials Manifold rail O-ring Screws Note on materials Wrought aluminium alloy NBR Steel RoHS-compliant Configuring the switch-off functions The sub-base is not a safety device, nor is it a complete safety solution. However, it can form part of a safety solution. Suitable accessories must be mounted at the function ports [3] and [34] in order to configure the different switch-off functions. Sub-base Silencer Blanking plug Exhaust air flow control valve Push-in fitting VABP-S3-6VG U-x B-x GRE-x QS-Gx-4, 6 or 8 VABP-S-VG U-x B-x GRE-x QS-Gx-4, 6 or 8 VABP-S-VG U-¼ B-¼ GRE-¼ QS-G¼-6, 8 or 0 Switch-off variants Circuit : Stopping a movement blocking When the valves are switched off, the movement of the drive will be stopped. Note: Following actuation of the switchoff function, the drive will be under pressure In the case of a vertical mounting position, it is possible that the payload will slowly drop Blanking plug 06/0 Subject to change Internet: www.festo.com/catalogue/... 7

Switch-off variants Circuit : De-energising exhausting When the valves are switched off, the drive will be exhausted. Note: Not suitable for a vertical mounting position without additional safety functions If the exhaust air flow control valves are closed, the drive will not be exhausted Exhausting is also possible via the silencer Exhaust air flow control valve or silencer Circuit 3: Reversing (advancing) and reducing speed When the solenoid valves are switched off, the movement of a retracting drive is reversed with simultaneous reduction of speed. The drive travels into the end position. Note: The holding function is time-limited To generate the reversing movement even in the event of compressed air failure, an air reservoir with nonreturn function can be inserted at port [3] for compressed air supply. Exhaust air flow control valve Push-in fitting 8 Internet: www.festo.com/catalogue/... Subject to change 06/0

Switch-off variants Circuit 4: Reversing (retracting) and reducing speed When the solenoid valves are switched off, the movement of an extending drive is reversed with simultaneous reduction of speed. The drive travels into the end position. Note: The holding function is time-limited To generate the reversing movement even in the event of compressed air failure, an air reservoir with nonreturn function can be inserted at port [34] for compressed air supply. Push-in fitting Exhaust air flow control valve Circuit 5: Switching off power short-circuit When the valves are switched off, the two chambers are interconnected. The drive comes to a stop. Note: Following actuation of the switchoff function, the drive will be under pressure Not suitable for a vertical mounting position without additional safety functions To restrict the run-out movement, it is recommended that a thin tube (4 or 6 mm) or a flow control valve (e.g. GRO...) is used for connecting the ports [3] and [34]. Push-in fitting Exhaust air flow control valve 3 One-way flow control valve 3 06/0 Subject to change Internet: www.festo.com/catalogue/... 9

Dimensions VABP-S3-6VG Download CAD data www.festo.com -H- Note Mounting only via the proportional directional control valve VPWP is not sufficient. The sub-base must also always be mounted directly using the through holes D4. B B B3 B4 B5 B6 B7 B8 With valves 54 39 7 46 9 0.5 33 D D D3 D4 D5 H H H3 Gx Gx M5 5.5 M4 With valves 96 39.5 0 H4 H5 H6 H7 H8 H9 L L ±0. ±0. 4 30 5 35.3 6 With valves 4.5 6 L3 L4 L5 L6 L7 L8 L9 L0 With valves ±0. ±0. ±0. ±0. 49.5 3 6 0 85 80 5.4 4.75 0 Internet: www.festo.com/catalogue/... Subject to change 06/0

Dimensions VABP-S-VG Download CAD data www.festo.com -H- Note Mounting only via the proportional directional control valve VPWP is not sufficient. The sub-base must also always be mounted directly using the through holes D4. B B B3 B4 B5 B6 B7 B8 With valves 86 60 6 4 70 6 5 58 D D D3 D4 D5 H H H3 G¼ Gx Gx 5.5 M4 With valves 96 48 4 H4 H5 H6 H7 H8 H9 L L ±0. ±0. 4 3 37 5 43 55 With valves 3 96 L3 L4 L5 L6 L7 L9 L0 With valves ±0. ±0. ±0. 56.5 34 7 48 93 8.5 5 06/0 Subject to change Internet: www.festo.com/catalogue/...

Dimensions VABP-S-VG Download CAD data www.festo.com -H- Note Mounting only via the proportional directional control valve VPWP is not sufficient. The sub-base must also always be mounted directly using the through holes D4. B B B3 B4 B5 B6 B7 B8 With valves 0 75 0 55 87 3 3 66 D D D3 D4 D6 D7 H H H3 H3 Gy G¼ Gx 6.6 4.5 8 With valves 96.5 48.5 H3 H4 H5 H6 H7 H8 H9 L ±0. ±0. 4.3 6 36 5 43.5 With valves 57 5 L L3 L4 L5 L6 L8 L9 T With valves 00 ±0. ±0. 66 38 5.5 44 08 0 8.4 Internet: www.festo.com/catalogue/... Subject to change 06/0

Ordering data Nominal flow rate Part No. Type 800 605074 VABP-S3-6VG-G8-400 64860 VABP-S-VG-G4-000 73867 VABP-S-VG-G38- With valves 800 605075 VABP-S3-6VG-G8-M-R3 400 64863 VABP-S-VG-G4-M-R3 000 73867 VABP-S-VG-G38-M-A -H- Note The solenoid valve VSVA with switching position sensing must be ordered separately 4 06/0 Subject to change Internet: www.festo.com/catalogue/... 3

Accessories Ordering data Solenoid valve Description Part No. Type PU ) For sub-base: VABP-S3-6VG-G8-534546 VSVA-B-M5-MZH-A-R5L For sub-base: VABP-S3-6VG-G8- With switching position sensing via inductive proximity sensor 56076 VSVA-B-M5-MZ-A-C-APP For sub-base: VABP-S-VG-G4-56373 VSVA-B-M5-MZD-D-R5L For sub-base: VABP-S-VG-G38-5978 MNH-5/-D--FR-S-C Solenoid coil For solenoid valve: MNH-5/-D--FR-S-C 3060 MSNG-4DC-OD Blanking plug For realising a switch-off function 3568 B-x 0 3569 B-¼ Silencer For realising a switch-off function 649 UC-x 65004 UC-¼ Exhaust air flow control valve For realising a switch-off function 035 GRE-x 035 GRE-¼ One-way flow control valve For realising a switch-off function 93969 GR-QS-6 93970 GR-QS-8 ) Packaging unit 4 Internet: www.festo.com/catalogue/... Subject to change 06/0

Accessories Ordering data Description Part No. Type PU ) Push-in fitting (only use push-in fitting with sealing ring) For pilot air port 4 VABP-S3-6VG 30896 QSM-B-M5-6-0 0 VABP-S-VG 86096 QS-Gx-6 0 VABP-S-VG 86098 QS-Gx-8 0 For function ports 3, 34 VABP-S3-6VG 86096 QS-Gx-6 0 VABP-S-VG 86098 QS-Gx-8 0 VABP-S-VG 86099 QS-G¼-8 0 For working ports, 4,, 44 VABP-S3-6VG 86098 QS-Gx-8 0 VABP-S-VG 860 QS-G¼-0 0 VABP-S-VG 8603 QS-Gy- 0 Connecting cable and plug socket with cable Connection of solenoid valve to proportional directional control valve VPWP. For the solenoid valves: VSVA-B-M5-MZH-A-R5L VSVA-B-M5-MZD-D-R5L Connection of solenoid valve to controller. For the solenoid valves: VSVA-B-M5-MZH-A-R5L VSVA-B-M5-MZD-D-R5L 38465 NEDV-LR-V7-MW3-K-0.L-N-M8W4-0.R 54363 NEBU-MG5-K-.5-LE3 54364 NEBU-MG5-K-5-LE3 Connection of solenoid valve to controller. For solenoid valve with switching position sensing VSVA-B-M5-MZ-A-C-APP 5688 KMEB--4-,5-LED 5689 KMEB--4-5-LED Connection of solenoid valve to controller. For solenoid valve: MNH-5/-D--FR-S-C 3093 KMC--4DC-,5-LED 30933 KMC--4DC-5-LED Connection of switching position sensing system to controller 54334 NEBU-M8G3-K-5-LE3 Plug and plug socket Alternative plug socket for solenoid valve. For solenoid valve with switching position sensing VSVA-B-M5-MZ-A-C-APP Alternative plug socket for solenoid valve. For solenoid valve: MNH-5/-D--FR-S-C 5687 MSSD-EB 34583 MSSD-C Insulation displacement connector Connection of the connecting cable KMC to the proportional directional control valve VPWP Screw terminal Connection of the connecting cable KMC to the proportional directional control valve VPWP 5605 NECU-S-M8G4-HX 06898 NECU-S-M8G4-C ) Packaging unit 06/0 Subject to change Internet: www.festo.com/catalogue/... 5