Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Circuit breaker operating mechanisms for use with and circuit breakers in enclosures up to in. deep. -pole, V AC rating,, and A circuit breaker frame sizes Complete kits with accessories Field installed Can be used with enclosure Types, R,, X, and Can be field installed on a right-flanged or left-flanged enclosure Lockable handle Table of Contents... - Specifications... - Approximate Dimensions... - Standards Compliance UL CSA C., No. Certifications UL Recognized(File No. E, Guide No. NLDX) CSA Certified (File No. LR) Circuit Breaker Kits Optional accessories listed below can be added to the circuit breaker kits to create () cat. no. Example: Cat. No. V-C-A-B-F Circuit Breaker Kits include: Connecting rod Metal handle Circuit breaker operating mechanism (circuit breaker to be supplied by customer) -Pole Circuit Breaker Operating Mechanism Brand Frame Size [A] Frame Designation Cat. No. U-H (MCCB), M-H (MPCB + MCP) EG, HMCPE M-I (MPCB + MCP), U-I (MCCB) EHD, FD, FDB, FDC, HFD, HMCP U- (MCCB), M- (MPCB + MCP) G V-C V-C V-C D, DB, DC, HD, HMCP V-C Kit U-K (MCCB), M-K (MPCB + MCP) KD, KDB, KDC, HKD, HMCP V-C Bulletin V Kit Field Installed Circuit Breaker Frame Size [A] Description Suffix Code Longer Connecting Rod (-/ -/ in.) A A A A A Disconnect Handle Stainless Steel B A A A A Disconnect Handle Non-Metallic C A A A A N.O. F A A A A Auxiliary Contact includes adapter kit N.O. FF A A A A N.C. G A A A A N.C. GG A A A A Metal handle provided as standard. For stainless steel handle, select suffix code B. For non-metallic handle, select suffix code C. Publication A-CAA-EN-P -
Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Selection Circuit Breaker Components Components Circuit Breaker Operating Mechanism The mechanism listed must be combined with a connecting rod, operating handle, and a circuit breaker (supplied by customer) to obtain a functional device. -Pole Circuit Breaker Operating Mechanism Brand Frame Size [A] Frame Designation Cat. No. U-H (MCCB), M-H (MPCB + MCP) EG, HMCPE U-I (MCCB) EHD, FD, FDB, FDC, HFD, HMCP, M-I (MPCB + MCP) U- (MCCB), M- (MPCB + MCP) G V-M V-M V-M D, DB, DC, HD, HMCP V-M U-K (MCCB), M-K (MPCB + MCP) KD, KDB, KDC, HKD, HMCP U-L (MCCB, MPCP, MCP) Circuit breakers to be provided by customer. Connecting Rods Approximate dimensions are in inches (millimeters). Approximate dimensions are not intended for manufacturing purposes. Circuit Breaker Frame Size [A],,, Operating Handle V-M Enclosure Depth Minimum Maximum Cat. No. -/ () -/ () V-RA -/ () -/ () V-RA Handle Type Description Mounting Circuit Breaker Frame Size [A] Operating Handle Cat. No. Type, R,, X, Nonmetallic Right or Left Flange,,, F-P Type, R,, Painted Metal Right or Left Flange,,, F-M Type, X Stainless Steel Right or Left Flange,,, F-S - Publication A-CAA-EN-P
Bulletin Auxiliary Contacts Auxiliary Contacts ( A Disconnect Switch only) Description For Use With Cat. No. N.O. Contact N.O. Contact (low-level switching) C, F, V, and G ( A) Disconnect Switches -N -NX N.C. Contact -N D, V ( N.C. Contact (low-level A Frame) Circuit Breakers switching) -NX N.O. Contact Cat. No. -A Cat. No. -B N.C. Contact C, G, and V Disconnect Switches A only -B Auxiliary Contact Adapter Kit For A -N Disconnect Switches Cat. No. -N Cat. No. -N Cat. No. -N Cat. No. -N Cat. No. -N Cat. No. -N Auxiliary Contact Adapter Kit For Disconnect Switches with Left-Hand Mechanism Auxiliary Contact Adapter Kit For Circuit Breakers Electrical Interlocks Electrical Interlock Adapter Kit A Disconnect Switch A Disconnect Switch A and A Frame, A, A Frame, A Frame, A Frame, A, A, A Frame N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early N.O. and N.C. early A DPDT early break (for A, Type & R only) A DPDT early break (for A, Type ) A DPDT early break (for all A, A, & A, Type, R, and ) A Disconnect Switch V Disconnect Switch with Left-Hand Mechanism, A V Disconnect Switch with Left-Hand Mechanism, A D, V Circuit Breakers -A -N -N -N V Circuit Breaker -N D Circuit Breaker -N D Circuit Breaker -N D Circuit Breaker -N C, G & V Disconnect Switches with Left-/Right-Hand Mechanism, A & Right-Hand Mechanism, A C, G, & V Disconnect Switch with Right-Hand Mechanism, A, A C and V Disconnect Switch with Left-Hand Mechanism, A V Disconnect Switch with Left-Hand Mechanism, A V Disconnect Switch with Left-Hand Mechanism, A H Safety Switch C, G, V Disconnect Switch Requires an adapter kit on new installations. One adapter kit enables up to two auxiliary contacts to be installed. Additional adapter kit (Cat. No. -N) required for installation on A switch. -N -N -N -N -N -N -N -N -N -N -N -N -N - Publication A-CAA-EN-P
Bulletin Lug Connectors ( per package) Disconnect Size [A] Description For Use With Cat. No. Wire Size # AWG Wire # AWG Wire R-N # / AWG Wire C, F, G, and R-N V Disconnect # / AWG Wire Switches R-N # MCM Wire (oversized) -LF () of #/ MCM Wire R-N # AWG MCM Wire (oversized) R-N () of #/ MCM Wire R-N () of #/ MCM Wire -N or -R R-N Cat. No. R-N () of # MCM Wire A fuse blocks R-N Ground Connectors Ground Lug Kits A C, F, G, and -GR V Disconnect A Switches -GR A -GR, A H & HL Safety -GR Cat. No. -GR, A Switches -GR Neutral Kits A @ /V AC Fusible (Type & R) -NK A @ /V AC Non-Fusible (Type & R) -NK A @ /V AC Fusible & Non-Fusible (Type ) -NK A @ /V AC Fusible & Non-Fusible (Type & R) -NK A @ /V AC Fusible (Type ) -NK A @ /V AC Non-Fusible (Type ) H Safety Switches -NK A @ /V AC Fusible (Type & R) -NK A @ /V AC Non-Fusible (Type, R, and ) -NK A @ /V AC Fusible (Type ) -NK A @ /V AC Fusible & Non-Fusible (Type & R) -NK A @ /V AC Fusible & Non-Fusible (Type ) -NK Phase Barrier Kits Disconnect Size [A], C, F, G, F-PH V F-PH F-PH F-PH All terminals of the A switches are furnished with self-lifting pressure plate connectors as standard. Each kits contains () lugs. Each kit contains () lugs. Publication A-CAA-EN-P -
Bulletin Fuse Clips ( per package) Fuse Class H R Description For Use With Cat. No. V Fuse Clip Rating [A] V -N C, F, G, and V Disconnect Switches -N -N -N -N -N C, F, G, and V Disconnect Switches -N C, F, G, and V Disconnect Switches -N C, F, G, and V Disconnect Switches -N C, F, G, and V Disconnect Switches -N C, F, G, and V Disconnect Switches -N V-FS Fuse Blocks -N -N C, F, G, and -N V Disconnect Switches -N -N -N H, R Fuse Blocks Class R Fuse Clip Kits A @ V AC (Type, R, ) -N A @ V AC (Type, R) -N A @ V AC (Type ) -N A @ V AC (Type, R, ) H Safety Switches -N A @ V AC (Type, R, and ) -N A @ /V AC (Type & R) -N A @ /V AC (Type ) -N A @ /V AC (Type, R, and ) -N A @ V AC (Type & R) -N A @ V AC (Type & R) -N HL Safety Switches A @ V AC (Type & R) -N A @ V AC (Type & R) -N Included with Bulletin separate mounted fuse blocks. One fuse block kit per pole required. Fuse clips not required; fuse bolts directly to terminal. - Publication A-CAA-EN-P
Bulletin Protective Fuse Covers (for use with Bul. C, F, G, and V disconnect switches) Fuse Clip Rating [A] Switch Rating [A] Fuse Class V V Cat. No. H, R H, R -N H, R H, R -N H, R -N H,, R -N H,, R -N H,, R -N H,, R -N -N H,, R -N Protective Line Covers (for use with Bul. C, F, G, and V disconnect switches),, -N -N -N -N Terminal Lug Adapter Kit allows two wires (maximum AWG) to be installed on the line side or load side (for use with Bul. C, F, G, and V disconnect switches) R-N R-N R-N, R-N Switch with right-hand mechanism. Switch with left-hand mechanism. Used with Bulletin -Nand -R on Bulletin V/C/G. Publication A-CAA-EN-P -
Bulletin Description For Use With Cat. No. Defeater Bracket Extension Kit For use with operating handles that do not align properly with the door catch or door hardware on enclosures with a rolled lip flange construction. All F and V Handles (except V-R and V-R) V-H Channel Support Kits For use to prevent flexing of the operating handle mounting surface. This is especially useful when the operating handle is mounted on a channel in a multi-door enclosure. A Switches Applies only to Operating Handle Cat. Nos. F-P, M, and S. V-H Packaged in quantities of. Conduit Hubs (for Type R enclosures) A, A, A. mm (/ in.) hub -N. mm ( in.) hub A, A -N. mm (-/ in.) hub A H Safety Switches -N. mm (-/ in.) hub A -N. mm ( in.) hub -N. mm (-/ in.) hub A -N Non-Metallic Conduit Connectors / in. (. mm) A -N / in. ( mm) A -N in. (. mm) A -N -/ in. (. mm) A -N -/ in. (. mm) A -N in. (. mm) A -N -/ in. (. mm) A -N in. (. mm) A -N G Disconnect Switches Grounding Adapters # AWG, / in. (. mm) A -N # AWG, / in. ( mm) A -N # AWG, in. (. mm) A -N # AWG, -/ in. (. mm) A -N # / AWG, -/ in. (. mm) A -N # / AWG, in. (. mm) A -N # / AWG, -/ in. (. mm) A -N # / AWG, in. (. mm) A -N - Publication A-CAA-EN-P
Bulletin Cat. No. V-L Decription For Use With Cat. No. Type Door Hardware Kit Includes: handle, cam, defeater actuator lever, rollers, and shims Enclosure Height less than in. ( mm) Top and Side (Right Hand) Top and Side (Left Hand) Enclosure Height in. ( mm) Top and Side (Right Hand) Bottom Top and Side (Left Hand) Bottom Enclosure Height greater than in. ( mm) C, All V V-L V-LL V-L and V-L V-LL and V-L V-L Top, Side, and Bottom (Right Hand) Cat. No. V-L Cat. No. V-L Top, Side, and Bottom (Left Hand) V-LL Type Door Hardware Kit Includes: Handle, cam, defeater actuator lever, rollers, and shims Cat. No. F-L and F-L Enclosure Height less than in. ( mm) Top and Side (Right Hand) Top and Bottom (Right Hand) Enclosure Height in. ( mm) Top and Bottom (Right Hand) Side Enclosure Height greater than in. ( mm) Top, Side, and Bottom (Right Hand) Master Door Interlock Kits Interlock kits are designed to provide interlocking between the master and auxiliary doors of the same enclosure and for use with Cat. Nos. F-L hardware kits or Cat. No. V-L hardware kits. Specify one master door kit and as many auxiliary door kits as necessary ( maximum). Connecting bars must be supplied by user. F, D C, F, D, V F-L F-L F-L and F-L F-L F-N Cat. No. F-N Auxiliary Door Interlock Kit F-N Door hardware kit does not include rectangular connecting bars (/ x / in.). To be provided by customer. Door hardware kit does not include rectangular connecting bars (/ x / in.). To be provided by customer. Master door interlock kit does not include rectangular connecting bars (/ x / in.). To be provided by customer. If the Rockwell Automation door hardware kits are to be installed in a commercially available enclosure, consult the enclosure manufacturer's application data for proper kit selection. Publication A-CAA-EN-P -
Bulletin Specifications Bulletin C, F, G, R, V Disconnect Switches Disconnect Switch Electrical Ratings Switch Size A A A A A A Rated insulation voltage Ui (UL) IEC () V V/ Hz. V/ Hz Hp Ratings V/ Hz UL/CSA/NEMA V DC Ratings IEC Applications Continuous Current Maximum kw (AC) V AC V DC V/ Hz V/ Hz V/ Hz. Auxiliary Contact Electical Ratings NEMA/EEMAC B, P Ui V I th A V IEC Ratings V ACII U x V V Low level switching ma @ V DC Mechanical Degree of protection Non-metallic Type, R,, X,, Operating Painted Type, R,, handles Stainless steel Type, X Mechanical life (Typical) operations ( A) operations ( A) Switching frequency (operations/hr),,, and A sizes max. and A sizes max. Environmental Temperature Operating - + C (- + F) Storage - + C (- + F) Altitude (per IEC -) m per IEC - Relative Humidity (per IEC -) % at C ( F) and % at C ( F) Design Specification/Test Requirements Dielectric strength V for minute Electrical life operations at rated current A: unfused Short Circuit Withstand Capability A: with Class H fuses A: with Class or Class R fuses Construction Switch body material Phenolic Contact material Copper, tin-plated Terminals A A A A A A All wire rated C ( F) or higher must be sized per the local Electric Code for C ( F) wire. Conductor Size (mm) A A A A A A A A Recommended Torque A A A A Switches, Mechanisms, and Accessory Kits # - screw and self-lifting pressure plate / in. - screw-lug, copper / in. - screw-lug, copper / in. - screw-lug, copper / in. - screw-lug, copper / in. - screw-lug, copper # AWG (. mm) # AWG (. mm) # / AWG ( mm) # / AWG ( mm) of #/ AWG MCM ( per lug) of mm MCM or () # AWG MCM of #/ AWG MCM ( per lug) of mm MCM or () # AWG MCM Conductor into Lug lb in lb in lb in lb in lb in lb in Zinc-plated steel, RoHS Compliant finish I e Lug to Terminal lb in lb in lb in lb in lb in lb in A A. A. A - Publication A-CAA-EN-P
Bulletin Approximate Dimensions Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Bulletin V Circuit Breaker Auxiliary (When Used) Common Industrial Flange Cut-Out Trailer Fuse Block Vertical Center Line of Operation Handle Drilling Door Provides for Wire Bending Space Disconnecting Means Enclosure Flange Operating Handle Mounting Surface Disconnect Means Mounting Surface Bulletin V A / (.) Dia Holes Vertical Center Line of Operating Handle Flange Cut-Out Center Line Operating Mechanism Square Corners or / (.) R. Bulletin V A Disconnect Switches NEMA Size [A] A -/ () -/ () -/ () -/ (.) (.) -/ (.) B Max. Min. Max. -/ () -/ () -/ (.) -/ (.) -/ (.) -/ (.) -/ () -/ () -/ () -/ (.) -/ (.) -/ (.) Approximate dimensions are for reference only. This approximate dimension will vary by fuse class and size. Approximate dimension with Class fuses. C -/ () -/ () -/ () -/ () -/ () -/ () D E F -/ (.) -/ (.) -/ (.) -/ (.) (.) (.) -/ () -/ () -/ () -/ () () -/ (.) -/ (.) -/ (.) -/ (.) -/ () -/ (.) -/ (.) Switch Mounting Hole Diameter / in. / in. / in. / in. / in. / in. Circuit Breakers Frame A U-H, M-H, EF, HMCPE A U-I, M-I EHD, FD, FDB, FDC, HFD, HMCP A U-, M- A D, DB, DC, HD, HMCP A U-K, M-K KD, KDB, KDC, HKD, HMCP A U-L A (.) -/ (.) -/ (.) Approximate dimensions are for reference only. Min. -/ (.) -/ (.) -/ (.) C Max. (.) -/ (.) -/ (.) D E F (.) () (.) -/ (.) -/ (.) -/ (.) () -/ (.) -/ (.) Publication A-CAA-EN-P -