VTC-1.5 HALT/HASS Chamber Specifications

Similar documents
VTC-16 HALT/HASS System Speciation

TC-9 Rapid Thermal Chamber Specifications

VTC- 16 HALT/HASS System Specifications

Auxiliary Equipment. Option #397-12A Single Remote Pumping Unit (with Standard Pump & Motor) Duplex Remote Pumping Unit Option #397-12B

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

ETV-SERIES VIBRATION INTERFACE ENVIRONMENTAL TEST CHAMBER. High performance & inherent reliability

1291BL Series Technical Specification Single Axis Position and Rate Table System

Heating oven with mechanical control

SE-SERIES ENVIRONMENTAL TEST CHAMBERS

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

Heating chamber with mechanical convection

Heating chamber with mechanical convection

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

Heating oven with natural convection

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Heating oven with mechanical convection

Size: 57 (140 cm) W. x 30 (75 cm) D. x 75 (190 cm) H.

DCH Commercial Contents Standard Features Cabinet Features

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

Cyclic Corrosion Test CORR Series

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h

THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE MANUAL

Model ED 720 Drying and heating chambers Classic.Line with natural convection

13,000 Watt Diesel Generator AGi13P E

HYDROVAR IncReAseD flexibility AnD control with new generation

Model ED 400 Drying and heating chambers Classic.Line with natural convection

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

10,000 Watt Diesel Generator AGi9P E

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

UD SERIES COMPRESSORS

Gate valve control system Series 64

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

CATALOG OF REPLACEMENT PARTS

FS & TS. 2 Zone Vertical or Rotary and 3 Zone Vertical Thermal Shock Chambers. Environmental Test and Space Simulation Systems.

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

VTZ variable speed Reciprocating compressors

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Document Code: 1 (8) Issuing date: Status:

DEVELOPMENTAL HALT Report R XSS S Power Supplies. Michael Farragher Engineering Test Technician Test Performed By

Specification of Battery Charger

Climate chamber with illumination

Cyclic Corrosion Chamber C.C.T AUTO Series

(770) Turning Parts Changers Into TROUBLESHOOTERS!

HV-100E HYDROVECTION OVEN REPLACEMENT PARTS LIST

Climate chambers with illumination

MKT 240 (E3) - Environmental simulation chamber for complex temperature profiles in the low temperature range

Agilent 6850 Series II Network GC System G2630A Performance Specifications

hv-100e hydrovection oven

Mistral LC-MS Evolution Specification

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

Centrifugal Chiller Single Compressor WSC048, WSC050 TSC048, TSC050 HSC048, HSC050 PL

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c

MODEL 422 Submersible Pump Controller

Safety Exhaust Valve Integration Guide

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Hydraulic Concentrate Control Valve

UPGRADE PROGRAM. V141 Series Pumps vs Turbo-301 Series Pumps. Technical Memo

VT Oil-Free Range Operators Handbook

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Refrigerated incubator with Peltier technology

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Temperature Cycling Chambers Global-N Series

HV gate valve with protective ring Series 17

ROGERS MACHINERY COMPANY, INC

GENERAL PURPOSE INCUBATOR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR Kanpur , Uttar Pradesh, India Centre for Lasers and Photonics

Direct Gas-Fired Make-up Air Heaters

ROBBINS 53RH C. Low-profile raise drill for holes ranging from 1.2 to 2.4 m (4-8 ft.) in diameter

Graco PD44. Patented Meter, Mix and Dispense Valve for Two-Component Micro Dispensing

Technical Data Sheets

Specification GS329 1

HMV Variable Motors Data and Specifications

TSS Single-Duct VAV Terminals

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h

geass.com Environmental simulation chambers for cyclic temperature testing MK MKT series Alternating temperature and climate testing

CTi Automation - Phone: Fax: Web:

B BASIC HEAT TREATMENT CONSOLE

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Specification of Battery Charger

Hydrovar and Packaged Hydrovar

Advanced Techniques US Inc.

Features and Benefits. Control Features

TECHNICAL SPECIFICATIONS DESCRIPTION: - CENTAC COMPRESSOR 2

Technical Specification SENTINEL PRO

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

technical catalogue tetris KW Chiller and heat pumps air/water

TLE Series UPS 160/200/225/250 kw with eboost Technology

Safety drying ovens. Advantages: Areas of application: FDL series 115

Plumbing S Plumbing S Frame S-100. Enclosure A20H16CLP. Pump & Motor S-400 FRONT RIGHT ISO VIEW NEW LOGIC RESEARCH

Transcription:

VT-1.5 Specification www.hanseenv.com +1-269-673-8638 VT-1.5 HALT/HASS hamber Specifications NEW IMPROVED! Design VT-1.5 hamber 5/5/15 Page 1 of 9 REV 2.0

VT-1.5 Specification System Features 3 Summery of Hanse hamber Features 4 Summery of Hanse Vibration Features 5 Performance 6 hamber onstruction 6 Instrumentation 7 Software 7 Safety 7 Utilities 7 Installation 7 Options 8 Hanse VT Series Stander hambers Offerings 9 5/5/15 Page 2 of 9 REV 2.0

VT-1.5 Specification System Features HALT/HASS hamber: Up to100 Grms with markedly improved Air onsumption/grms. U.S. Patentend. This new and improved system is based on15 years of continuous development and combines rapid thermal cycling of products under test with six-degree-of freedom (6DoF), singularly, or in combination. High Rate Liquid Nitrogen ooling System: 3 Phase Solid-State Infitrol proportional control of balanced electric heaters wire balanced system. Optional Solid Rod Heaters for extended high temperature testing. HighRate Liquid Nitrogen ooling System: Direct atomization in control plenum, solenoid control and redundant solenoid safety valve. Vibration Table and Vibrators: Vibration Table with ceramic surface thermally insulates table surface from vibration table base for improved temperature cycling and vibrator life. Vibration enhancing mounting standoffs for improved vibration energy transfer and air circulation under test specimen. LubeMist lubricated vibrators with adjustable ball valves, one for each pneumatic vibrator for low G-level performance using fewer vibrators. SoftStart designed vibrators minimize starting shock to products.. System Warranty: Three (3) year warranty for Vibration Table, Vibrators, ontroller, and Heater SR. 5/5/15 Page 3 of 9 REV 2.0

VT-1.5 Specification Summery of Hanse hamber Features HAMBER FEATURES Pressurized plenum Proportional heating, vibration 4-20ma, ooling Solenoid SR heater control and breaker isolated Breakers on all 3 phases lines All instruments and related board on breakers Watch Dog circuit available on request Front Panel Display and manual control Programable maintenance PL optional Interlocked safeties doors, fans, heat, cool, vibration Balanced heater system Hanse 3 Phase monitored for phase loss and balance Fans monitored and interlocked for running Heaters and LN2 interlocked to fans running Timer to hold heat, cool, and vibration until fans running Electrical meets all NE code with UL / E marked components hamber vented by one 4 vent on rear Positive dry air purge in chamber, can be changed to GN2 One 12 x 12 Window Optional window on side Halogen 120VA adjustable lights FM approved High/Low Limit control with user set able Multi point manual door latch points Galvanneal Paintlok external liner Over sized hinges for door stability All wires and terminals clearly labeled Full set of wiring and air schematics 5/5/15 Page 4 of 9 REV 2.0

VT-1.5 Specification Summery of Hanse Vibration Features VIBRATION FEATURES Range of vibration 0 to 70 GRMS (25-30 ) Easy Self starting vibrators Self oiling vibrator system High tempter hose with bulk head fittings Easy removable hose (JI fitting) Ball valve control on each vibrator Harden piston for long life and low wear Low air consumption vibrator Vibrators work in -100 to +200 environment Requires clean dry air Balanced vibrators for load size Vibrators able to be retrofit to other systems Three (3) size vibrators available Precision air control regulators insulated vibration table Stainless steel mounting insert 3/8-16 or M10 Full table surface no restrictions eramic cover insulation Gasket around table from environmental compartment Hanse 3 Year warranty on table and vibrators 5/5/15 Page 5 of 9 REV 2.0

VT-1.5 Specification Performance 1.1 Temperature 1.1.1 Range: -75 to +175 (-100 to +200 Optional) 1.1.2 Air hange Rate: 70 /min (-65 to 100 ) 1.1.3 Stabilization: ± 1 after stabilization. (Stabilization < 2 minutes). 1.1.4 ooling: Liquid Nitrogen (LN2) direct injection. 1.1.5 Heating: 30 KW SR ontrolled (Optional Solid Rod heaters) 1.1.6 Thermocouples: One (1) air, one (1) for specimen. 1.2 Vibration 1.2.1 Tri-Axial: Six-Degree-of-Freedom (6DoF) Vibration, non-coherent broadband vibration 10-10,000Hz, up to 70 Grms (100 GRMS Optional), at 25 to 30 with unloaded table. 90% of vibration energy in 5-4000Hz for maximum low energy in low frequency range. 1.2.2 Table: 20 x 20 (508mm x 508mm) with twenty-five (25) 3/8-16 (M10) standoff mounting inserts. 1.2.3 Accelerometers: One (1) Model Dytran 3030B5, 500 Grms Range with cable and three axes mounting block. 1.2.4 Vibration Actuators: Three (3) Medium pneumatically actuated. Table vibration, ± 1 Grms within one (1) minute of settling. 1.2.5 Maximum Load: 250 lbs.(113.3 kg) hamber onstruction 2.1 Interior 2.1.1 Upper: 24 W x 24 D x 23 H (610mm x 610mm x 584mm) 2.1.2 Lower: 24 W x 24 D x 34 H (610mm x 610mm x 863mm) 2.2 Exterior: 40 W x 42 D x 81 H (1098mm x 889mm x 2057mm) 2.3 Doors: One (1). One full opening 2.4 Windows: One (1) Tempered Multi-pane. 12 x 12 (305mm x 305mm) in door. 2.5 Light: Two (2) lights adjustable. 2.6 Ports: Two (1) 6 dia. (152mm) for customer use. 2.7 Insulation: Hanse s exclusive multilayer staggered insulation for superior thermal and noise insulation. 2.8 Sound Level: Nominal 73 dba @ 1 meter 2.9 Weight: 1000 lbs (453 kg) 5/5/15 Page 6 of 9 REV 2.0

VT-1.5 Specification Instrumentation 3.1 HanseView Programmable Temperature and ontrol: Programmable temperature ramps. losed loop cascade temperature control of product under test including RS232/485 serial interface. HALT step-stress templates included for easy HALT chamber programming. 3.2 Thermocouples: One (1) for temperature control and one (1) for product response. 3.3 Programmable Vibration ontrol: Programmable vibration ramps, Grms level, and test duration all synchronized with the temperature controller. 3.4 Accelerometers: One (1) accelerometer, cable and 3 axes mounting block provided. Four (4) channel GRMS meter capability to allow a total of four (4) accelerometers to be monitored simultaneously. Optional analysis package allows up to 12 accelerometers to be monitored. 3.5 Serial Ports: RS232/485 MODBUS Software 4.1 HanseView : For temperature and vibration programming, control, and data logging control sensors. Safety 5.1 Door Interlocks: Door Interlocks shut off system operation. 5.2 Emergency Power Off (EPO): EPO activation shuts off system operation 5.3 Over/Under Limit: FM approved limit with stand-alone sensor placed in air. Utilities 6.1 Electric: 480V 3 Ph 50 FLA (Other Voltages on Request) 6.2 Liquid Nitrogen: 3/8 (9mm) Supply 40/50 psig 6.3 ompressed Air: 1/2 (13mm) Supply, 25 SFM 6.4 Exhaust Ports: One (1) 4 (102mm) dia. vented to outside. Installation 7.1 The customer is responsible for unloading system and rigging into place. 7.2 Utilities and services necessary for system operation, electrical, LN2, compressed air, exhausts, etc. shall be provided by customer and connected to the system. 7.3 Any leasehold improvements or building alterations are the responsibility of the customer. 5/5/15 Page 7 of 9 REV 2.0

VT-1.5 Specification Options 8.1 Humidity: Direct Injection, 10 to 85% RH from 25 to 65, apacitance Sensor. 8.2 HanseView TM Vibration Analyzer: ontrol/analyzer/data Logger with 4 Accelerometer channels. 8.2.1 Additional Accelerometer hannels: Additional four (4) Accelerometer channels up to a total of sixteen (16). Includes urrent Source. 8.2.2 Additional 14 thermocouples: Total of 16 monitored (1 dedicated plenum air, 1 specimen). Data is integrated into HanseView ontrol or Analyzer. 8.3 Additional Accelerometer: Model Dytran 3030B5, 500 Grms Range with cable. 8.4 Additional Mounting Block: Three axes. 8.5 ommunication Ports: Optional Ethernet TP/IP. 8.6 Vibration Fixtures: Specially designed for HALT/HASS applications. 8.7 LN2 System: omplete installation, piping and controls. 8.8 Anti ondensate: Heaters to assist in frost or condensation on door and external surface of chamber and windows. 8.8 Stand-Alone: 1.8.1 Temperature ycling hambers 1.8.2 Six- degree-of-vibration (6dof) Vibration Tables 9.9 Upgrades 9.9.1 Vibration Level: 70 GRMS increased to 100 GRMS with larger 24 x24 Table 9.9.2 Temperature Range: Range increased to -100 to + 200. hamber insulation type and wall thickness. Note: Specifications are subject to change without notice. Any Hanse chamber can be modified to fit your requirements. 5/5/15 Page 8 of 9 REV 2.0

VT-1.5 Specification Hanse VT Series Stander hambers Offerings ontact sales@hanseenv.com +1-269-673-8638 WWW.HanseEnv.com Hanse VT Specifications 2015 (Vibratrion Thermal hambers) VT-1 VT-1.5 VT-4 VT-6 VT-9 VT-9 Eco VT-16 VT-18 VT-25 VT-32 VT-36 Table Size Inch 12x12 20x20 24x24 30x30 36x36 36x36 48x48 36x78 60x60 48x102 70x70 Internal Workspace WxDxH Inch 18x18x18 24x24x23 24x24x34 30x30x36 36x36x36 42x42x38 42x42x50 42x42x38 54x54x38 54x54x50 42x84x36 42x84x50 66x66x38 66x66x50 54x108x38 54x108x50 76x76x38 76x76x50 External Inch WxDxH 28x30x70 40x42x81 60x44x95 66x49x96 72x55x107 72x55x96 84x67x107 72x110x107 96x79x107 84x134x107 106x89x107 Temperature Range -60 to 175-75 to 175 hange Rate 60 /Min 70 /Min 70 /Min 70 /Min 70 /Min 70 /Min 70 /Min 70 /Min 70 /Min 70 /Min 70 /Min Max Load lbs. 100 250 700 700 700 700 500 500 500 500 500 Doors Front Front Front and Rear Front and Rear Front and Rear Windows 1 1 2 2 4 2 4 4 4 4 4 Ports 2 x 4 1 x 6 2 x 6 2 x 6 3 x 6 2 x 6 3 x 6 6 x 6 2 x 1 3 x 6 6 x 6 2 x 1 3 x 6 Liquid Nitrogen 40-50 psig 3/8 NPT 3/8 NPT 1 NPT 1 NPT 1 NPT 1 NPT 1 NPT 1 NPT 1 NPT 1 NPT 1 NPT ompressed Air*** ompressed Air Inlet NPT*** 1/2 1/2 3/4 3/4 1" 1 1 2 x 1 1.25 (1.5 **) 2 x 1" 1.25 (1.5 **) Air Flow SFM*** 15 25 45 55 120 120 100 (200*) 120 (240*) 150 (300*) 200 (400) 225 (450*) FLA 480V 3 PH 30** 50 60 125 125 125 125 150 175 250 245 FLA 380V 3 PH 20 65 75 160 160 160 160 190 220 315 310 Weight lbs. 650 1,000 1,900 2,500 4,000 3,500 4,250 7,000 6,000 8,500 7,000 Note: * Ultra High Requires 1/4 added to Supply Size ** 240V 3 Phase *** T models ompressed air Inlet is 1/2 NPT 100 PSI 10 SFM All Specifications subject to change. 1 5/5/15 Page 9 of 9 REV 2.0