HARMONIC FILTER REACTOR

Similar documents
Power Factor Correction Capacitors in sheet steel cases

MODVAR Low voltage reactive power compensation modules Installation manual

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

LV Capacitor CLMD03 Power Module Instruction manual

High Reliable Components for Power Factor Correction and Power Quality

Capacitor Switching Contactors Type K3...-A, K3...-K

CTU 02. Thyristor switching module for fast PF compensation. User manual

High Reliable Components for Power Factor Correction and Power Quality

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

AIR CORE REACTORS. Phoenix Electric Corporation

Transforming Energy.. For Advanced Technology

Medium Voltage Capacitors

Three Phase Capacitors KNK

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A

multicond Power capacitors Data sheet: multicond

LV Capacitor CLMD Reliability for Power Factor Correction

LV Capacitor Bank APC

VW3A4552 line/motor choke - 4 mh - 10 A - 3 phases - 65 W - for variable speed drive

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

LV Capacitor Bank APC

CONVERTER-FED MOTOR LOSSES

VW3A4552 line/motor choke - 4 mh - 10 A - 3 phases - 65 W - for variable speed drive

Automatic COSYS PFC. Automatic power factor correction system NEW

CP Automatic capacitor bank

VW3A4552. Product datasheet Characteristics. Main 1 / 5

Easy Choice for Energy Efficiency

2 SLR Series Line Reactors... 50

ABB n.v Power Quality in LV installations

Power factor correction and harmonic filtering. Power capacitors Low Voltage

LED control gear Compact fixed output

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Mains Filters. IEC Connectors. IEC Connectors 292

This instruction manual must be read carefully and should be always given to the end user of the device.

AC/DC Arc Furnace and Ladle Furnace Transformers

Power Factor Correction Capacitors Harmonic Filter Reactors

100V 160V 200V 250V 400V

Tachogenerators Solid shaft ø11 to ø14 mm with flange

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

POWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar. Abel-Zhang,Power Quality Center Manager

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Unrestricted. Air Core Reactor Applications Current Limiting Reactors

R.4. Automatic capacitor banks with static system. Power factor correction and harmonic filtering. Homepage :

Automatic capacitor banks

Check points for the connection of Capacitor&Reactor

FUJI Magnetic Contactors and Motor Starters

RasuunDrive. HighVac 10mm - Type 3. Technical Supply Specifications: RasuunDrive HighVac 10mm - Type 3. Attributes. Highlights.

Global data. Electrical parameters

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

PSB / RSB - (Expanded range)

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

YN018GMFI16M2D-V V~ 60Hz 1Phase Serials: PRE

Dimensional Drawing 48ZJ94. Lake Forest, IL USA. Dayton Electric Mfg. Co. REV. - DRAWING NO. PAGE OF REV. 48ZJ94

Power Factor Correction

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

2-position electric actuators with Ball valves VBZ ½...11/4

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

IEC Connectors Mains Filters

COMPONENT Type SS21-UL Type

Power Factor Correction Capacitors Type LKT

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Power factor solutions for electric switchboards

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Power Factor Correction Equipment

INTERROLL DRUM MOTOR 113S

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:

Film Capacitors Power Factor Correction

Series A DC Link Chokes

Low Voltage Power Factor Corrections

Special Purpose Fuses

AC centrifugal fan with housing (small flange)

Application Note. Dynamic PFC: Power Quality at the Docks (China State Shipbuilding Corporation)

AC Line / Load Reactors

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

PhiCap Capacitors for Power Factor Correction

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm]

AC Motor Systems US Series

NH DIN Dual Indication Fuse Links

Thermal Overload Relays - WEG RW Series, 2 Pole

The information in this chapter will enable you to: 90VAC to 50/60 Hz

Power conversion systems for energy storage. Engineering that stores

MADE IN GERMANY. Components for reactive power compensation. Components for reactive power compensation. Power Quality. Reactive power controllers

Power capacitors Low Voltage

Selective main circuit breakers S 750 series Technical Data

Item: Type: SAW Resonator TO39, F11, F12. Optional

CLMD Low-voltage capacitors for reliable power factor correction

Motor Valve GS 1 series, DN 15 up to DN 150

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Actuator with. Attachment A1. Lc [mm] Stroke Stroke T [mm] Stroke Stroke

Braking Devices VB 230/ Assembly- and Commissioning Instructions

GENERAL CATALOG. Group of Companies

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Assembly- and Commissioning Instructions Braking Devices VB 230/

EPRLAB FAQ v1.0 Page 1 / 8 Copyright EPRLAB December 2015

Transcription:

380V 50Hz Series Resonance Frequency : 204Hz or p = 6% To be used with 415V capacitor only Design : According to VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV l 350 = 0.13 x l N 10 MH-GH-10-415-50 13.90 3.289 1 180 180 140 75 150 8 8.0 20 MH-GH-20-415-50 27.80 1.645 2 210 210 140 85 175 8 11.5 30 MH-GH-30-415-50 41.70 1.096 2 210 210 140 95 175 8 14.7 40 MH-GH-40-415-50 55.60 0.822 2 230 240 140 92 200 8 17.5 50 MH-GH-50-415-50 69.60 0.658 2 230 240 140 92 200 8 18.0 60 MH-GH-60-415-50 83.50 0.548 2 230 240 160 100 200 8 21.0 70 MH-GH-70-415-50 97.40 0.470 2 255 270 155 103 225 10 23.4 80 MH-GH-80-415-50 111.30 0.411 2 255 270 170 95 225 10 26.5 90 MH-GH-90-415-50 125.20 0.365 2 255 270 170 95 225 10 27.0 100 MH-GH-100-415-50 139.10 0.329 2 255 270 180 110 225 10 28.5

380V 50Hz Series Resonance Frequency : 189Hz or p = 7% To be used with 415V capacitor only Design : According to VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV l 350 = 0.11 x l N 10 MH-GH-10-415-50 13.90 3.837 1 180 180 140 73 150 8 9.0 20 MH-GH-20-415-50 27.80 1.919 2 210 210 145 85 175 8 14.5 30 MH-GH-30-415-50 41.70 1.279 2 210 210 155 100 175 8 16.3 40 MH-GH-40-415-50 55.60 0.959 2 230 240 155 92 200 8 18.0 50 MH-GH-50-415-50 69.60 0.767 2 230 240 150 105 200 8 20.2 60 MH-GH-60-415-50 83.50 0.640 2 230 240 150 105 200 8 21.0 70 MH-GH-70-415-50 97.40 0.548 2 255 270 160 100 225 10 25.0 80 MH-GH-80-415-50 111.30 0.480 2 255 270 165 100 225 10 26.5 90 MH-GH-90-415-50 125.20 0.426 2 255 270 165 102 225 10 28.5 100 MH-GH-100-415-50 139.10 0.384 2 255 270 170 105 225 10 30.0

Filtering with Holly harmonic circuit filter reactor provides the 400V 50Hz Series Resonance Frequency : 204Hz or p = 6% To be used with 440V capacitor only Design : According VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV l 350 = 0.11 x l N 10 MH-GH-10-440-50 13.10 3.697 1 240 210 120 70 175 8 10.0 20 MH-GH-20-440-50 26.20 1.849 1 240 210 125 80 175 8 11.0 30 MH-GH-30-440-50 39.40 1.232 2 210 210 135 90 175 8 13.5 40 MH-GH-40-440-50 52.50 0.924 2 230 240 140 95 200 8 17.5 50 MH-GH-50-440-50 65.60 0.739 2 230 240 150 100 225 8 21.0 60 MH-GH-60-440-50 78.70 0.616 2 255 270 160 105 225 10 24.8 70 MH-GH-70-440-50 91.90 0.528 2 255 270 170 120 225 10 28.6 80 MH-GH-80-440-50 105.00 0.462 2 255 270 180 115 225 10 30.0 90 MH-GH-90-440-50 118.10 0.411 2 255 270 180 115 225 10 31.0 100 MH-GH-100-440-50 131.20 0.370 2 255 270 190 120 225 10 32.5

Filtering with Holly harmonic circuit filter reactor provides the 400V 50Hz Series Resonance Frequency : 189Hz or p = 7% To be used with 440V capacitor only Design : According VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV l 350 = 0.11 x l N 10 MH-GH-10-440-50 13.10 4.314 1 240 210 120 70 175 8 10.2 20 MH-GH-20-440-50 26.20 2.157 1 240 210 125 80 175 8 11.5 30 MH-GH-30-440-50 39.40 1.438 2 210 210 135 90 175 8 14.0 40 MH-GH-40-440-50 52.50 1.078 2 230 240 140 95 200 8 18.0 50 MH-GH-50-440-50 65.60 0.863 2 255 270 160 110 225 8 26.0 60 MH-GH-60-440-50 78.70 0.719 2 255 270 170 110 225 10 27.0 70 MH-GH-70-440-50 91.90 0.616 2 255 270 180 115 225 10 29.0 80 MH-GH-80-440-50 105.00 0.539 2 255 270 185 120 225 10 31.0 90 MH-GH-90-440-50 118.10 0.479 2 255 270 185 120 225 10 32.5 100 MH-GH-100-440-50 131.20 0.431 2 255 270 200 130 225 10 33.8

415V 50Hz Series Resonance Frequency : 204Hz or p = 6% To be used with 525V capacitor only Rated Voltage : 600V Load Carrying Capacity : Insulation Class : 155 C or Class F l N = Current from Q LC without harmonic load Thermo-protection : Fitted with 135 C thermostat l 250 = 0.31 x l N Design : According to VDE 0550/0532 & IEC 76 l 350 = 0.11 x l N Ambient Temperature : 60 C, maximum ambient temperature l TH = 1.22 x l N = Max. permissible effective value of Linearity Characteristics : 1.50 x 1 N at no change of inductivity the current considering 10% over 1.75 x 1 N at reduction of the inductivity voltage and the permissible harmonic currents 10 MH-GH-10-525-50 11.00 5.264 1 240 210 130 70 175 8 10.0 20 MH-GH-20-525-50 22.00 2.632 1 240 210 135 80 175 8 11.5 30 MH-GH-30-525-50 33.00 1.755 2 210 210 150 93 175 8 14.0 40 MH-GH-40-525-50 44.00 1.316 2 230 240 155 95 200 8 17.3 50 MH-GH-50-525-50 55.00 1.053 2 230 240 160 100 200 8 20.0 60 MH-GH-60-525-50 66.00 0.877 2 255 270 155 95 225 10 23.0 70 MH-GH-70-525-50 77.00 0.752 2 255 270 175 100 225 10 26.0 80 MH-GH-80-525-50 88.00 0.658 2 255 270 180 115 225 10 28.8 90 MH-GH-90-525-50 99.00 0.585 2 255 270 180 115 225 10 29.5 100 MH-GH-100-525-50 110.00 0.526 2 255 270 185 115 225 10 32.0

415V 50Hz Series Resonance Frequency : 189Hz or p = 7% To be used with 525V capacitor only Rated Voltage : 600V Load Carrying Capacity : Insulation Class : 155 C or Class F l N = Current from Q LC without harmonic load Thermo-protection : Fitted with 135 C thermostat l 250 = 0.31 x l N Design : According to VDE 0550/0532 & IEC 76 l 350 = 0.11 x l N Ambient Temperature : 60 C, maximum ambient temperature l TH = 1.22 x l N = Max. permissible effective value of Linearity Characteristics : 1.50 x 1 N at no change of inductivity the current considering 10% over 1.75 x 1 N at reduction of the inductivity voltage and the permissible harmonic currents 10 MH-GH-10-525-50 11.00 6.141 1 240 210 130 70 175 8 10.2 20 MH-GH-20-525-50 22.00 3.071 1 240 210 135 80 175 8 12.3 30 MH-GH-30-525-50 33.00 2.047 2 230 240 140 80 200 8 14.5 40 MH-GH-40-525-50 44.00 1.535 2 230 240 155 92 200 8 18.0 50 MH-GH-50-525-50 55.00 1.228 2 230 240 175 100 200 8 25.7 60 MH-GH-60-525-50 66.00 1.024 2 255 270 180 110 225 10 26.0 70 MH-GH-70-525-50 77.00 0.877 2 255 270 200 120 225 10 30.2 80 MH-GH-80-525-50 88.00 0.768 2 255 270 200 120 225 10 31.2 90 MH-GH-90-525-50 99.00 0.682 2 255 270 200 120 225 10 32.5 100 MH-GH-100-525-50 110.00 0.614 2 255 270 215 130 225 10 34.5