N2XY IEC XLPE PVC 0.6/1kV Cable

Similar documents
BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

SY PVC / BS EN Control Flexible Cable

Firetec BS 7846 LPCB BASEC Approved Power Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

6491B / H07Z-R / BS EN Cable

RFOU 0.6/1kV Power Cable

BFOU 0.6/1kV Power Cable

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

o o blue-brown Fire Performance BS EN BS EN

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Power & Control Cable IEC

Power & Control Cable IEC

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

BS 6724 Armoured Power Cables, 600/1000V

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

AAAC - ASTM - B All Aluminium Alloy Conductor

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

FR-3S Fire Resistant Cables

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Technical Data Sheet Shielded (CY) PVC Control Cable

BS6724 SWA/LSZH Cable IEC /1000V

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

Power & Control Cable IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

The cables you need when you need them

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath.

LSZH Fire Resistant Cables

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

SY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8

Technical Data Sheet Shielded (CY) PVC Control Cable

Power & Control Cables

Complete range of transformers for any applications or size

600/1000V, PVC Insulated Cables according to IEC

1 Conductor Class 5 flexible annealed plain copper conductor

Your Partner in Safe Power Solutions. About RESCAB

Technical Data Sheet Shielded (CY) PVC Control Cable

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

N2XSERY 3 x (25-300) mm² 3.6/6 kv

NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

H07RN-F TITANEX (industrial flexible)

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

600/1000V, XLPE Insulated Cables according to IEC

Data sheet chainflex CFSOFT1

Chemical resistance Accidental

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

Unarmoured Single-Core Cables to BS6883

Building & Infrastructure Cables DELIVERING ENERGY

N2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

Data sheet chainflex CF8821

ACSR - ASTM - B Aluminium Conductor Steel Reinforced

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison.

CONTROL CABLES CABLES FZE.

flame Retardant overall screened Instrumentation cables (Multicore)

Any inquiries, please feel free to contact or Caledonian

Technical attributes

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

Caledonian Medium Voltage Cables

H05 V-K PVC-Single Cores, fine wire stranded

0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable

LOW VOLTAGE c a b l e s

PRODUCT INFORMATION H07V-K

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF

Company Profile. Caledonian Medium Voltage Cables

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

3. Fire Resistant Cables

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

Data sheet chainflex CF130.UL

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN

ÖLFLEX CLASSIC 110 CY

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

Data sheet chainflex CF5

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Cables for Railway Technology

Global data. Electrical parameters

Data sheet chainflex CF240

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

Transcription:

N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls. CONSTRUCTION Conductor RE: Class 1 solid copper conductor according to BS EN 60228 RM: Class 2 stranded circular or circular compacted conductor according to BS EN 60228 Insulation XLPE (Cross-Linked Polyethylene) Bedding PVC (Polyvinyl Chloride) Sheath PVC (Polyvinyl Chloride) CABLE STANDARDS IEC 60502-1, BS EN/IEC 60332-1-2, VDE 0276 part 603 The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Eland Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed. CHARACTERISTICS Voltage Rating (Uo/U) 600/1000V Temperature Rating During installation -5 C to +50ºC Fixed Installation: -20 C to +90 C Permissible operating temperature at conductor +90 C (Short circuit temperature: 250ºC) Minimum Bending Radius 12 x overall diameter Core Identification 1 core: Black 2 core: Blue Brown 3 core: Brown Black Grey 3 core including earth: Brown Blue Green/Yellow 4 cores: Blue Brown Black Grey 4 core including earth: Green/Yellow Blue Brown Black 5 cores: Blue Brown Black Grey Black 5 core including earth: Green/Yellow Blue Brown Black Grey 7 cores and Higher: Black cores and White numbers + Green/Yellow Sheath Colour Black technicalspecification 1 of 6

DIMENSIONS ELAND PART NO. NO. OF CORES ² OF INSULATION OF SHEATH NOMINAL OVERALL DIAMETER NOMINAL WEIGHT kg/km N2XY Power Cable - 1 core A2N2XY116 1 16RM 0.7 1.8 9.8 216 A2N2XY125 1 25RM 0.9 1.8 11.5 318 A2N2XY135 1 35RM 0.9 1.8 12.6 415 A2N2XY150 1 50RM 1 1.8 14.1 543 A2N2XY170 1 70RM 1.1 1.8 15.6 746 A2N2XY195 1 95RM 1.1 1.8 17.6 1000 A2N2XY1120 1 120RM 1.2 1.8 19.2 1239 A2N2XY1150 1 150RM 1.4 1.8 21.2 1515 A2N2XY1185 1 185RM 1.6 1.8 23.1 1872 A2N2XY1240 1 240RM 1.7 1.8 25.8 2403 A2N2XY1300 1 300RM 1.8 1.8 27.8 2974 A2N2XY1400 1 400RM 2 1.9 31.1 3834 A2N2XY1500 1 500RM 2.2 2 34.9 4892 A2N2XY1630 1 630RM 2.8 2.8 46.6 6544 N2XY Power Cable - 2 core A2N2XY2015 2 1.5RE 0.7 1.8 10.1 145 A2N2XY2025 2 2.5RE 0.7 1.8 10.9 179 A2N2XY2040 2 4RE 0.7 1.8 11.8 226 A2N2XY2060 2 6RE 0.7 1.8 12.8 284 A2N2XY2060 2 6RM 0.7 1.8 13.1 295 A2N2XY210 2 10RM 0.7 1.8 15 416 A2N2XY216 2 16RM 0.7 1.8 17 581 A2N2XY225 2 25RM 0.9 1.8 20.4 859 A2N2XY235 2 35RM 0.9 1.8 22.5 1109 N2XY Power Cable - 3 Core A2N2XY3015 3 1.5RE 0.7 1.8 10.5 162 A2N2XY3025 3 2.5RE 0.7 1.8 11.4 205 A2N2XY3040 3 4RE 0.7 1.8 12.4 265 A2N2XY3060 3 6RE 0.7 1.8 13.4 338 A2N2XY310 3 10RM 0.7 1.8 15.8 505 A2N2XY316 3 16RM 0.7 1.8 18 719 A2N2XY325 3 25RM 0.9 1.8 21.6 1072 A2N2XY335 3 35RM 0.9 1.8 23.9 1403 A2N2XY350 3 50SM 1 1.9 23.8 1581 N2XY Power Cable - 3 core with smaller earth conductor A2N2XY316/10 3 16RM/10RM 0.7 1.8 19.8 875.5 A2N2XY325/16 3 25RM/16RM 0.9/0.7 1.8 22.4 1223 A2N2XY335/16 3 35RM/16RM 0.9/0.7 1.8 24.3 1557 A2N2XY350/25 3 50RM/25RM 1/0.9 1.9 26.9 1863 A2N2XY370/35 3 70RM/35RM 1.1/0.9 2 30 2594 A2N2XY395/50 3 95RM/50RM 1.1/1 2.2 33.8 3505 A2N2XY3120/70 3 120RM/70RM 1.2/1.1 2.3 37 4440 A2N2XY3150/70 3 150RM/70RM 1.4/1.1 2.4 41.6 5333 A2N2XY3185/95 3 185RM/95RM 1.6/1.1 2.6 45.8 6701 A2N2XY3240/120 3 240RM/120RM 1.7/1.2 2.8 51.6 8674 A2N2XY3300/150 3 300RM/150RM 1.8/1.4 3 67.2 10624 2 of 6 technicalspecification

ELAND PART NO. NO. OF CORES ² OF INSULATION OF SHEATH NOMINAL OVERALL DIAMETER NOMINAL WEIGHT kg/km N2XY Power Cable - 4 core A2N2XY4015 4 1.5RE 0.7 1.8 11.3 188 A2N2XY4025 4 2.5RE 0.7 1.8 12.2 240 A2N2XY4040 4 4RE 0.7 1.8 13.3 314 A2N2XY4040 4 4RM 0.7 1.8 14 335 A2N2XY4060 4 6RE 0.7 1.8 14.5 408 A2N2XY4060 4 6RM 0.7 1.8 14.9 421 A2N2XY410 4 10RM 0.7 1.8 17.1 615 A2N2XY416 4 16RM 0.7 1.8 19.6 885 A2N2XY425 4 25RM 0.9 1.8 23.7 1330 A2N2XY435 4 35RM 0.9 1.8 26.2 1758 A2N2XY450 4 50RM 1 2 27.1 2082 A2N2XY470 4 70RM 1.1 2.1 31.4 2937 A2N2XY495 4 95RM 1.1 2.2 35 3955 A2N2XY4120 4 120RM 1.2 2.4 39.3 4979 A2N2XY4150 4 150RM 1.4 2.6 43.6 6129 A2N2XY4185 4 185RM 1.6 2.7 48 7591 A2N2XY4240 4 240RM 1.7 2.9 53.9 9875 A2N2XY4300 4 300RM 1.8 2.6 68.9 15124 N2XY Power Cable - 5 core A2N2XY5015 5 1.5RE 0.7 1.8 12.1 218 A2N2XY5025 5 2.5RE 0.7 1.8 13.1 281 A2N2XY5040 5 4RE 0.7 1.8 14.3 372 A2N2XY5040 5 4RM 0.7 1.8 15.2 397 A2N2XY5060 5 6RE 0.7 1.8 15.6 486 A2N2XY5060 5 6RM 0.7 1.8 16.1 502 A2N2XY510 5 10RM 0.7 1.8 18.6 740 A2N2XY516 5 16RM 0.7 1.8 21.3 1071 A2N2XY525 5 25RM 0.9 1.8 25.9 1619 A2N2XY535 5 35RM 0.9 1.8 28.8 2138 A2N2XY550 5 50RM 1 2.1 29.4 2578 A2N2XY570 5 70RM 1.1 2.2 33.7 3616 A2N2XY595 5 95RM 1.1 2.4 38.6 4933 A2N2XY5120 5 120RM 1.2 2.5 42.6 6153 A2N2XY5150 5 150RM 1.4 2.7 47.7 7587 A2N2XY5185 5 185RM 1.6 2.9 52.8 9454 A2N2XY5240 5 240RM 1.7 3.1 58.7 12242 N2XY Power Cable - 7 core A2N2XY7015 7 1.5RE 0.7 1.8 12.9 260 A2N2XY7025 7 2.5RE 0.7 1.8 14 342 A2N2XY7040 7 4RE 0.7 1.8 15.4 461 A2N2XY7040 7 4RM 0.7 1.8 16.3 490 N2XY Power Cable - 10 core A2N2XY10015 10 1.5RE 0.7 1.8 15.6 357 A2N2XY10025 10 2.5RE 0.7 1.8 17.2 475 A2N2XY10040 10 4RE 0.7 1.8 19 646 A2N2XY10040 10 4RM 0.7 1.8 20.2 688 technicalspecification 3 of 6

ELAND PART NO. NO. OF CORES ² OF INSULATION OF SHEATH NOMINAL OVERALL DIAMETER NOMINAL WEIGHT kg/km N2XY Power Cable - 12 Cores A2N2XY12015 12 1.5RE 0.7 1.8 16.1 394 A2N2XY12025 12 2.5RE 0.7 1.8 17.6 528 N2XY Power Cable - 14 Cores A2N2XY14015 14 1.5RE 0.7 1.8 16.8 436 A2N2XY14025 14 2.5RE 0.7 1.8 18.5 592 N2XY Power Cable - 16 Cores A2N2XY16040 16 4RM 0.7 1.8 23 971 N2XY Power Cable - 19 Cores A2N2XY19015 19 1.5RE 0.7 1.8 18.4 543 A2N2XY19025 19 2.5RE 0.7 1.8 20.3 746 N2XY Power Cable - 24 Cores A2N2XY24015 24 1.5RE 0.7 1.8 21.2 675 A2N2XY24025 24 2.5RE 0.7 1.8 23.4 931 N2XY Power Cable - 30 Cores A2N2XY30015 30 1.5RE 0.7 1.8 22.3 788 A2N2XY30025 30 2.5RM 0.7 1.8 26.3 1164 N2XY Power Cable - 40 Cores A2N2XY40015 40 1.5RE 0.7 1.8 24.6 995 A2N2XY40025 40 2.5RE 0.7 1.9 27.5 1416 CONDUCTORS Class 1 Solid Conductors for Single-Core and Multi-Core Cables 2 MAXIMUM RESISTANCE OF CONDUCTOR AT 20 C Circular, Annealed Copper Conductors Plain ohms/km 0.5 36 0.75 24.5 1 18.1 1.5 12.1 2.5 7.41 4 4.61 6 3.08 4 of 6 technicalspecification

Class 2 Stranded Conductors for Single-Core and Multi-Core Cables 2 MINIMUM NO. OF WIRES IN THE CONDUCTOR MAXIMUM RESISTANCE OF CONDUCTOR AT 20 C Circular Circular Compacted Annealed Copper Conductor Cu Cu Plain Wires ohms/km 4 7 6 4.51 6 7 6 3.08 10 7 6 1.83 16 7 6 1.15 25 7 6 0.727 35 7 6 0.524 50 19 6 0.387 70 19 12 0.268 95 19 15 0.193 120 37 18 0.153 150 37 18 0.124 185 37 30 0.0991 240 37 34 0.0754 300 61 34 0.0601 400 61 53 0.0470 500 61 53 0.0366 ELECTRICAL CHARACTERISTICS Current Carrying Capacity at 30 C 2 Flat In Ground Trefoil SINGLE CORE Flat In Air Trefoil In Ground 2-40 CORE In Air 1.5 - - - - 31 24 2.5 - - - - 40 32 4 82 54 57 44 52 42 6 102 67 72 56 64 53 10 136 89 99 77 86 74 16 176 115 131 102 112 98 25 229 148 177 138 145 133 35 275 177 217 170 174 162 50 326 209 265 207 206 197 70 400 256 336 263 254 250 95 480 307 415 325 305 308 120 548 349 485 380 348 359 150 616 393 557 437 392 412 185 698 445 646 507 444 475 240 815 517 774 604 517 564 300 927 663 901 697 585 649 400 1064 749 1060 811 - - 500 1227 843 1252 940 - - technicalspecification 5 of 6

DE-RATING FACTORS For Ground Temperatures other than 20 C GROUND TEMPERATURE 10ºC 15ºC 20ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC DE-RATING FACTOR 1.07 1.04 1.00 0.96 0.93 0.89 0.85 0.80 0.76 For Air Temperatures other than 30 C AIR TEMPERATURE 20ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC DE-RATING FACTOR 1.08 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.71 The information contained within this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances. 6 of 6 technicalspecification