IDENTIFYING DISC COUPLING FAILURES COUPLING FUNDAMENTALS

Similar documents
Unit Material Handling Conveyor Solutions

Unit Material Handling Conveyor Solutions

Full Complement Cylindrical Roller Bearings

Drives for the Metals Industry

Think you ve reached all the low hanging fruit for energy efficiency in your facility?

Lift Truck Replacement Chain

EXPERIENCE, INNOVATION AND CLOSE COOPERATION WITH LEADING INTERNATIONAL COMPANIES.

SYSTEM PLAST NEW CURVE CONCEPT

Experience the Difference Aerospace and Specialty Bearings

PRECISION BELLOWS COUPLINGS

JAURE. Experience, innovation and close cooperation with leading international companies.

V-BELT DRIVES AND BEARINGS

SEALED SPHERICAL ROLLER BEARING

Troubleshooting Power Transmission Couplings

EPT Mounted Bearing Technical Support. Phone: FAX: Mounted Bearing Application Engineering

MOVING YOUR BUSINESS FORWARD

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

GROVE GEAR PRODUCTS BROCHURE

GENERAL INDUSTRY WIND MARINE METALS & HEAVY DUTY

4-in-1 MOTORS ONE SIMPLE CONNECTION

Introduction. Lubrication Related Failures. Gear Couplings. Failure Analysis All Types (Page 1 of 7)

General Industry drives

ALL PRODUCTS CATALOG

lea) shows a compression type. These couplings are used for

DESIGNED FOR DIVERSITY MULTIDIRECTIONAL ROLLER TOP BELT SERIES 2253 RT

MULTIFIT MOTOR SPECIFICATIONS FEATURES

BoWex FLE-PA. BoWex FLE-PAC. KTR-N Sheet: Edition: EN 1 of BoWex FLE-PA / FLE-PAC Operating/Assembly instructions

GatesFacts Technical Information Library Gates Compass Power Transmission CD-ROM version 1.2 The Gates Rubber Company Denver, Colorado USA

SOLUTIONS FOR POWER TRANSMISSION. Wind power drives

Torque Limiter 320 Series Overview. Torque Limiter 320 Series

ROLLER BEARINGS FOR THE METALS INDUSTRY

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

Carbon Fibre Shaftlines JCFS

Extra Heavy Duty Modular Belts 2508 & 2630 Series

RADEX -N Composite Operating/Assembly instructions

TYPE HSFE/HLFE/HTFE H SERIES HIGH PERFORMANCE COUPLINGS

Why Choose Rexnord? 866-REXNORD/ (Within the U.S.) (Outside the U.S.)

Type A10. Falk Freedom Disc Couplings Installation and Maintenance. Type A10 Sizes 85 thru 8770 (Page 1 of 5)

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY

RM Flexible Disc Coupling

Maximum Performance Contoured Diaphragm Couplings

THE ART OF PERFORMANCE GEARING POWERED BY EXPERIENCE

AGN 076 Alternator Bearings

Expansion & contraction

JAUFLEX ELASTIC COUPLINGS

Synchronous Belt Failure Analysis Guide

TYPE HSRE/HLRE/HTRE H SERIES HIGH PERFORMANCE COUPLINGS

Fundamental Specifications for Eliminating Resonance on Reciprocating Machinery


Clay McClinton Rotating Equipment Reliability Analyst, Chevron. Dan Phillips Manager Global Field Services, Kop-Flex

SHAFT ALIGNMENT: Where do I start, and what is the benefit?

RM Flexible Disc Coupling

Six keys to achieving better precision in linear motion control applications

BEARINGS. Engineered Bearings for Your Applications

GatesFacts Technical Information Library Gates Compass Power Transmission CD-ROM version 1.2 The Gates Rubber Company Denver, Colorado USA

ROTEX Operating/Assembly instructions Type AFN-SB spec. ROTEX

AUTOFLEX DISC COUPLINGS

Disc Couplings 101. Ameridrives. Bauer Gear Motor. Bibby Turboflex. Boston Gear. Delroyd Worm Gear. Formsprag Clutch. Guardian Couplings.

The Importance of Shaft Alignment

CRES. of Mind. A Better Design... for Healthy Peace EMERSON POWER TRANSMISSION. Mounted Ball Bearings. CRES-00

Gearbox Misalignment on Combustion Gas Turbine Generator

Pulley Alignment. Parallel Misalignment

Type AB with limitation of axial backlash

DESIGN OF MACHINE ELEMENTS UNIVERSITY QUESTION BANK WITH ANSWERS. Unit 1 STEADY STRESSES AND VARIABLE STRESSES IN MACHINE MEMBERS

SKF Explorer angular contact ball bearings. Designed to run faster, cooler, smoother, longer

Autogard Torque Limiter 820 Series Overview. Autogard Torque Limiter 820 Series

Pile-driving analyses of monopiles with pre-installed flanges

Engineering Manual Multidirectional Roller Top Belt Series 2253RT

PIP REEE003 Guidelines for General Purpose Non-Lubricated Flexible Couplings

Riverhawk Company 215 Clinton Road New Hartford NY (315) Free-Flex Flexural Pivot Engineering Data

MARATHON MT SERIES CAST ALUMINIUM SINGLE & THREE PHASE GENERAL PURPOSE MOTORS SIZES , KW

TOOLFLEX Operating-/Assembly Instructions

F O R M. Rotating Biological Contractor Drives Installation and Maintenance Manual. 8368E Revised October Table of Contents.

HOW BELT DRIVES IMPACT OVERHUNG LOAD

LTI Cooling Tower Drive Shafts

Couplings - Balancing Tutorial & New Developments in Gas Turbine Couplings by Joe Corcoran & Christian Wolford

Piping Stress Considerations and Practical Remedies to Overcome Nozzle Misalignment and Vibration Related Issue

Introduction to Bellows Why bellows are used in Piping System?

Fault Diagnosis of Lakvijaya Power Plant: A Case Study of an Anti-Rotational Pin Failure

Installation and Maintenance Instructions Falk Wrapflex (Page 1 of 7) 1. General Information. 2. Safety and Advice Hints DANGER! Type 10R.

TYPE TSC/TLC T SERIES FLEXIBLE DISC COUPLINGS

Installation and Operational Instructions for EAS -Compact overload clutch, Type 49_. 4._ Sizes 4 and 5

Load Cell for Manually Operated Presses Model 8451

POWERLIGN TORQUE MONITORING SYSTEM

SHAFT ALIGNMENT FORWARD

Failures of Rolling Bearings in Bar and Rod Mill

laser shaft alignment

CLASSIFICATION OF ROLLING-ELEMENT BEARINGS

SKF Explorer spherical roller bearings Optimized for superior field performance

Technical Math 2 Lab 3: Garage Door Spring 2018

ISO INTERNATIONAL STANDARD

A L T R A I N D U S T R I A L M O T I O N. Ameriflex Diaphragm Couplings High Speed, High Performance Design

Module 6: Air Foundation Brakes

TSCHAN -B. Installation and Operation Manual TSCHAN Flexible Coupling BAWB 001-GBR-0 06/2004

A CASE STUDY OF A FLOW-INDUCED TORSIONAL RESONANCE

Retrofitting Turbomachinery with High Performance Flexible Dry Couplings

Comparison Chart. extremely difficult. Finally, separated components can rarely be re-used.

SKF FAG Timken NSK NTN

Vibration Diagnostic Software. Proven Automated Diagnostic Technology for Machinery Condition Assessment

Flexible Couplings 44

Transcription:

IDENTIFYING DISC COUPLING FAILURES While couplings are designed for infinite life, they must be operated within their intended design limits in order to achieve optimal performance. Due to installation issues and unforeseen events, a coupling may be subjected to loading greater than its rated capacity while in service. These issues can typically be identified through instrumentation or visual inspection, but not all coupling failures can be prevented. The modified Goodman diagram is created by modeling the theoretical mean and alternating stresses the coupling is subjected to at its maximum allowable ratings. The majority of disc couplings are operated within their recommended range, which has cultivated their reputation of reliability and safety. When a coupling is subjected to a torque and/or misalignment exceeding its rating, the stresses typically cannot be quantified accurately, making it impossible to accurately determine its remaining service life. Disc couplings are typically passive components compared to the other drivetrain equipment. They do not input any power or provide a process output, but simply connect the driving and driven equipment. The coupling may act as a litmus test and provide an early warning to a more significant problem, if the equipment experiences an issue. By understanding and identifying coupling failures, they can be prevented in the future resulting in the increased uptime of your equipment. There are a number of reasons why a coupling will operate in a misaligned condition. A few of the most common include: Installation & Human Errors Thermal Growth Worn Bearings Dynamic Twist of Skid Settling Bases / Foundations Pipe strain The axial alignment, or correct spacing between the flanges, ensures the coupling is being operated in a neutral position rather than under tension or compression. High performance couplings are typically provided with axial thermal growth values, which take into account the thermal expansion of the equipment, allowing the coupling to be installed in a prestretched condition. Disc couplings are d e s i g n e d t o accommodate this axial misalignment, but incorrect axial alignment or thermal growth values may impart an additional mean stress on the coupling or the equipment, adversely affecting performance. Key Points Disc couplings are designed for infinite life when operated within their recommended limits. The primary failure modes of disc couplings are due to excessive misalignment and torque overload. The failure mode can be identified through inspection of the disc pack. Future failures may be prevented through the inspection and identification of the root cause.

Prior to installation, the distance between the coupling flanges and the length of the coupling center section should be measured at four locations at 90 and averaged. Per API 671, Kop-Flex High Performance couplings are provided with shims in order to adjust the gap between flanges without requiring the equipment to be moved. The equation for determining the proper amount of shim can be seen expressed below where Calculated Separation is defined as the center section length plus thermal growth (Image 1). Shim Adjust = Measured Separation - Calculated Separation The maximum recommended operating misalignment for Kop-Flex couplings is 0.10 per disc pack. This limit is specified per flex half because while the angle due to offset misalignment is shared between the disc packs at either end, angular misalignment (α) results in an additional deflection on one side. While equipment tolerances are typically tighter than the rated coupling misalignment capacity, it can be helpful to determine if the coupling was installed within its designed operating range. It is also recommended that a hot check be performed to confirm the accuracy of the thermal growth offset values. Typical alignment techniques will report the horizontal and vertical alignment data in either face and rim runout (dial indicator) or angle in/in and offset (laser alignment). In order to determine if the installation is acceptable, trigonometry can be used to calculate the effective angle experienced by the coupling. The total acceptable angle is a combination of both the angular and offset misalignments. The simplified equation is expressed as: Image 1 Axial alignment calculation The maximum continuous axial misalignment rating of the coupling is determined from the geometry of the disc pack and listed on the coupling drawing. For optimal service life, it is recommended that the coupling be shimmed and installed to operate within 10% of the maximum axial alignment rating of the coupling. The angular and parallel offset misalignment rating of a typical disc coupling is specified in degrees per flex half. While a single flex disc coupling can only accommodate angular misalignment, a disc coupling with two flex halves accommodates a combination of both angular (α) and offset (S) misalignment as seen in Image 2. The distance between flex element of the coupling (L) plays a significant role in the determination of the angle. For a smaller (L) dimension due to a close coupled design or shorter DBSE (Distance Between Shaft Ends), the same offset (S) will result in a larger angle when compared to an installation with a longer DBSE (Image 4). Therefore, it is important to set up the alignment device to reflect the equipment being aligned. Image 2 Combination of angular and parallel offset misalignment. Image 3 With regards to offset (S), L dimension plays a significant role on effect angle at disc packs

When a disc coupling is subjected to angular misalignment, the highest stresses will be found in the outermost discs near the disc pack bolt hole (Image 4). This is the location Image 6 (L) Buckling in disc pack indicative of torque overload failures (R) Deformation in flange due to torque overload Image 4 Failure near clamping area of disc pack bolt indicative of angular misalignment issue of the highest bending stresses and therefore where disc couplings typically fail from cyclic fatigue due to high misalignment. Fretting, which can be mitigated by the use of a low friction coating on the discs, may also be present at the failure location due to movement between the discs. controlled drives on motors which can excite damaging resonant frequencies. Additionally, synchronous motor driven trains may experience high torsional oscillations during startups, so equipment that is subject to frequent startups is at higher risk. Torsional oscillations act as an additional alternating stress on the disc packs, which will typically fail at highly fretted locations in the center of the link between the disc pack (see Image 7). The failure of a disc coupling due to axial misalignment will show similar signs as angular misalignment. The discs may crack on both sides of the disc pack bolt hole, since the coupling is in compression or tension (Image 5). Image 7 Facture at center of link and fretting in link and at bolt hole, indicative torsional fatigue failure Image 5 Axial misalignment failure TORQUE The torque capacity of the coupling is typically determined during the design and selection phase. Since this is generally a well understood quantity, torque related failures frequently coincide with an atypical event, such as the ingestion of a liquid slug in a compressor or due to a hot shut down following an equipment trip. Torque related failures typically exhibit severe spreading or buckling of the disc pack and may result in the deformation of the flanges due to contact from the disc pack hardware (Image 6). Failures due to torsional fatigue are becoming more common due to the increased use of variable frequency Moderate oscillations may cause fatigue failures at the bolt holes or in adjacent tension and compression links, accompanied by considerable fretting. High magnitude torque fluctuations can result in bidirectional elongation of the disc pack at the bolt hole as well as distortion to the center section and other coupling components. CONCLUSION While designed for infinite life, the issues discussed above influence the effective service life of the coupling. The difficulty in quantifying stresses, either due to shifting equipment or transient torque spikes make it difficult to predict a coupling s remaining service life. Although technological advances in condition monitoring have decreased unanticipated failures, they may occur without warning or so rapidly that the equipment cannot be shut down in time. Knowing why a coupling fails is the first step to preventing it from occurring again in the future.

TYPE OF FAILURE SYMPTOMS TYPICAL CAUSES ANGULAR Fracture near bolt hole Fretting at fracture location Fracture may occur through bolt hole Thermal movements Foundation settling Pipe strain Loose anchor bolt/studs Poor initial alignment AXIAL Fracture near bolt hole May occur on both sides of bolt hole Incorrect thermal growth Equipment not on mag. center Incorrect magnetic center Poor initial alignment TORQUE OVERLOAD Buckling of disc pack Severe spreading Spreading in consecutive links Disc pack bolts may contact clearance holes Electrical fault Liquid slug in compressor High start up torque Operation/process event TORSIONAL OSCILLATION Fracture in center of disc link Fretting at clamping area and in the center of the link Oscillations from VFD Torsional issue Frequent startup on sync motor applications

you could get a likenew coupling for less? At Regal...we can repair your used couplings. While couplings are designed for infinite life, they must be operated within their intended design limits in order to achieve optimal performance. At Regal repair facilities worldwide, we have the equipment and expertise to repair your couplings at a typical savings of 50% over purchasing a new coupling. In two to six weeks, Regal engineers and field specialists work with clients to understand your application, make recommendations to improve life, create inspection reports and provide exact repair quotations. All required repairs are completed and the coupling is returned with all new hardware and its original factory warranty. For information about how we can help repair your coupling, call 800-626-2120 or visit us at www.regalpts.com/turbomachinery Regal Power Transmission Solutions Regal Beloit America, Inc. 7120 New Buffington Road Florence, KY 41042 Customer Service: 800-626-2120 Fax: 800-262-3292 Technical Service: 800-626-2093 www.regalpts.com APPLICATION CONSIDERATIONS The proper selection and application of power transmission products and components, including the related area of product safety, is the responsibility of the customer. Operating and performance requirements and potential associated issues will vary appreciably depending upon the use and application of such products and components. The scope of the technical and application information included in this publication is necessarily limited. Unusual operating environments and conditions, lubrication requirements, loading supports, and other factors can materially affect the application and operating results of the products and components and the customer should carefully review its requirements. Any technical advice or review furnished by Regal Beloit America, Inc. and/or its affiliates ( Regal ) with respect to the use of products and components is given in good faith and without charge, and Regal assumes no obligation or liability for the advice given, or results obtained, all such advice and review being given and accepted at customer s risk. For a copy of our Standard Terms and Conditions of Sale, please visit http://www.regalbeloit.com (please see link at bottom of page to Standard Terms and Conditions of Sale ). These terms and conditions of sale, disclaimers and limitations of liability apply to any person who may buy, acquire or use a Regal product referred to herein, including any person who buys from a licensed distributor of these branded products. Regal and Kop-Flex are trademarks of Regal Beloit Corporation or one of its affiliated companies. 2017 Regal Beloit Corporation, All Rights Reserved. MCB16039E Form# 10038E Printed in USA