Shafer RV-Series Rotary Vane Valve Actuators

Similar documents
Bettis GH-Series Pneumatic Spring-Return Actuator Torque Chart Imperial

Bettis GC01-Extension Series Extension Pneumatic Double-Acting & Spring-Return Actuator Torque Chart Metric

Bettis G01-Extension Series Extension Pneumatic Double-Acting & Spring-Return Actuator Torque Chart Imperial

CBA-Series Pneumatic Dimension Data Metric

Operating Instructions M3 and M3HW Jackscrew Manual Override. Service Instructions Rev. D October 2014

Shafer Poppet Block Control

Bettis TEC2 Electric Actuator with Model 500 Quick-Start Guide. Quick-Start Guide E2K Rev. 2 October 2017

Installation, Operation and Maintenance Manual DOC.IOM.MO.E October MO-Series Manual Override Gearboxes

Installation, Operation and Maintenance Manual HP/DHV Rev. 1 November Shafer Hand Pump-Double Holding Valve

Shafer SH Series Actuator. Service Manual SHSM Rev. 1 September 2016

PressureGuard. Self-Contained Hydraulic Emergency Shutdown Systems For Rotary or Non API 6A Linear Valves

Shafer RV-Series Rotary Vane Valve Actuators Valve Operating Systems for Critical Pipeline Applications

Gas/Hydraulic Valve Operators. Safe and Efficient Gas Pipeline Control

Safe and Efficient Gas Pipeline Control

Bettis Nuclear Series Actuators. Operation and Maintenance Manual VA Rev. E June 2014

EIM TEC2 Electric Actuator with Model 500 Quick-Start Guide

BETTIS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS FOR PNEUMATIC ROTARY VALVE ACTUATORS

Bettis RGS Q-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet April 2016 RGS Rev.

Installation, Operation and Maintenance Manual E Rev. D September Bettis Pneumatic Rotary Valve Actuators

GTD-Series. Direct Gas Actuators

GTD-Series. Direct Gas Actuators

HPUs Hydraulic Power Units

DRAFT. Installation, Operation and Maintenance Instructions for Emerson KBG-V Series

reliable actuators to

Multiport Flow Selector. Compact And Economical Production Test Manifold

HL-Series Electric Actuator Precision control for linear valves

Installation, Operation and Maintenance Manual RGS Rev. 0 November Bettis RGS F-Series Spring-Return Actuators

Shafer RV-Series Rotary Vane Valve Actuators Operating Valves in Critical Pipeline Applications

GVO Series Linear Valve Operators. Field-Proven for Safety Shutdown and Control

Disassembly and Reassembly for WG Series Worm Gear Operator. User Instructions Part Number: XXXXXX, Rev. 0 Release: February 2017

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

D-Series Rack & Pinion Pneumatic Actuators

CBA300 Series Pneumatic Actuators Improved Design - Compact, Lightweight To Suit All Applications And Environment

CBB-Series Scotch-Yoke Pneumatic Actuators Improved Design - Compact, Lightweight To Suit All Applications And Environment

Installation, Operation, and Maintenance Instructions for Bettis RGS F-Series Spring-Return (SR) Actuators

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR SPRING RETURN SERIES PNEUMATIC ACTUATORS

True Fail-Safe Technology and Precision Control for Reliable Shutdown

Pneumatic Rack & Pinion Actuators and Accessories

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY CB735-SR AND CB735A-SR SPRING RETURN SERIES PNEUMATIC ACTUATORS

CBB-Series Scotch-Yoke Pneumatic Actuators Improved Design - Compact, Lightweight To Suit All Applications And Environment

PWP Series - PressureGuard Wellhead Protection

Gas/Hydraulic Valve Operators. Safe and Efficient Gas Pipeline Control

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR MODELS HD521-S AND HD721-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

Protecting your actuation process without compromise in severe applications

True Fail-Safe Technology and Precision Control Meet Emergency Shutdown and Demanding Process Applications

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR MODEL HD732-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

Bettis CBB-Series Technical data sheet - Imperial and Metric

G-Series Pneumatic and Hydraulic Actuators. Next Generation Actuation Technologies Solutions

XL Pneumatic Actuators High on Quality High on Reliability... High on Service

EIM Product Selection Guide Proven Valve Automation and Control Solutions

Operating Instructions Rev. G March M11 Manual Hydraulic Override System For "HD", "T" and "G" series Pneumatic and Hydraulic Actuators

Bettis EHO Electro-Hydraulic Operator

Multiport Actuator and Multiport Flow Selector. Compact and economical production test manifold and actuator

Bettis CBA-300 Series Technical data sheet -

Hytork XL Pneumatic Actuator. Installation, Operation & Maintenance Manual MAC EN Rev. D February 2018

PressureGuard. Self-Contained Hydraulic Emergency Shutdown Systems

Bettis PressureGuard Self-Contained Hydraulic Emergency Shutdown Systems For Rotary or Non-API 6A Linear Valves

Shafer Linear Actuator. Installation, Operation and Maintenance Manual LSM Rev. A January 2001

EIM 2000 Series E796 M2CP. Installation and Maintenance Manual E2K Rev. 2 August 2017

EIM 2000 Series E1195 MCP. Installation and Maintenance Manual E2K Rev. 1 August 2017

BETTIS PressureGuard Self-Contained Hydraulic Emergency Shutdown Systems for Rotary or Non-API 6A Linear Valves

Service Instructions E Rev. D August CBAX30 Double-Acting Series Pneumatic Actuators Disassembly and Reassembly

Actuator Control Manual

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions

TEC2000 First came intelligent actuators. Now comes one with common sense.

Innovation in actuation.

Unleashing The Power of Valve Automation

Triple offset technology for lower pressures.

Actuator Control Manual with ESD Valve

WARNING. Mounting Instructions D103998X012 June DVC6200/DVC2000 Digital Valve Controller Linear Actuator Side Mount

Type 289RC Exhaust Booster

Fisher 1077 Manual Handwheel Rotary Actuator

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

WARNING. Mounting Instructions D103996X012 May DVC6200/DVC2000 Digital Valve Controller on Linear Actuator

FieldQ Pneumatic actuators and controls Fully integrated proven hardware and design

CBA-300 Series Pneumatic Actuators Improved design - compact, lightweight to suit all applications and environment

FieldQ Control Module QC40 AS-Interface

Rosemount 228. Toroidal Conductivity Sensor. Product Data Sheet July Series LIQ-PDS-228

Fisher 377 Trip Valve

Fisher 685 Piston Actuator

DeltaV SIS TM Auxiliary Components

Fisher 377 Trip Valve

Reduced Bore Thread-end Ball Valves Series 33R Model C. 1/2 2 (DN 15-50) AAR No. E079024

Fisher 3024C Diaphragm Actuator

VALVCON Universal ADC-Series Sealed Lead Acid Back-Up Battery Upgrade Kits. Installation, Maintenance and Operating Instructions

M1/M2 POCKET FEEDER. Compact design DESIGN FEATURES. Special ball and seat design. Large ball pocket capacity. Automatic cycling

Disassembly and Reassembly for CBAX30-SR (Spring Return) Series Pneumatic Actuators

SLAM-SHUT VALVE. Type OSE

Endurance TM Conductivity Sensors

RAP R10: Air Relay Valve Service and Adjustment ARV-69626/ /05/11. Air Relay Valve Service and Adjustment

Fisher 685SE and 685SR Piston Actuators

Bettis Q-Series Valve Actuator

HAND WHEEL OPERATOR For cylinder actuators Types B1C_K/L/R and B1C_RK/RL/RR Installation, Maintenance and Operating Instructions

Valve Automation Technologies from Emerson The most comprehensive and proven portfolio available anywhere

1/4" 2" (DN 8 50) A-STYLE MODEL D THREADED END 2000 CWP BALL VALVE

Manual E1195 (MCP) Series 2000

Fisher 8532 High-Performance Butterfly Valve

Fisher EZ-Overtravel (EZ-OVT) Valve Trim

Baumann Sanitary Control Valve

JAMESBURY EASYFLOW JT SERIES ANGLE STEM TANK BOTTOM VALVES

Transcription:

Shafer RV-Series Rotary Vane Valve Actuators Product Data Sheet RV-ASDD-D-3-06-09 Rev. 1 November 2017 Metric Units Dimension: Torque: Pressure: Weight: Volume: Centimeters (cm) Newton Meters (Nm) Bar Kilograms (kg) Cubic Centimeters(cm 3 ) Liters (L)

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09 Rev. 1 November 2017 Table of Contents Section 1: Actuator Specifications Sheet Actuator Specifications... 1 Section 2: Dimensional Data Sheets Dimensional Data... 8 I

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 1 of 11, Rev. 1 Actuator Specifications Note: 1/4 NPTF PORTS 13.33 Bolt circle, rotor bore, keyway quantity and size of mounting holes for RV-Series actuators will be custom fitted to specific valve. All dimension data is subject to change. All dimensions shown in centimeters. 13.33 7.94 22.23 6 1/2 x 2 Rotary Vane Actuator Torque expression: 18.84 Nm/bar Maximum working pressure: 103 bar Maximum test pressure: 207 bar Maximum acceptable valve stem: 6.66 cm. diameter Maximum wrench square: 5.08 cm. across flats Weight of actuator including hydraulic fluid: 17.7 kg. Actual fluid displacement per 90 stroke equals 0.34 L Gas consumption per 90 stroke equals 0.6 standard m 3 @ 69 bar Number of strokes of standard 66 cm 3 hand pump per 90 stroke equals 5.5 6 1/2 x 3 1/2 Rotary Vane Actuator Torque expression: 32.8 Nm/bar ¼ N PTF PO RTS 22.23 Maximum test pressure: 206.8 bar 17.15 11.75 Maximum acceptable valve stem: 6.67 cm. diameter Maximum wrench square: 5.08 cm. across flats 13.34 Weight of actuator including hydraulic fluid: 42.6 kg. Actual fluid displacement per 90 stroke equals 0.60 L Gas consumption per 90 stroke equals 0.2 standard m 3 @ 69 bar Number of strokes of standard 66 cm 3 hand pump per 90 stroke equals 9 22.23 6 1/2 x 8 Rotary Vane Actuator Torque expression: 77.56 Nm/bar ¼ N PTF PO RTS 28.58 23.18 Maximum test pressure: 206.8 bar Maximum acceptable valve stem: 6.67 cm. diameter Maximum wrench square: 5.08 cm. across flats 13.34 Weight of actuator including hydraulic fluid: 63.5 kg. Actual fluid displacement per 90 stroke equals 1.34 L Gas consumption per 90 stroke equals 0.2 standard m 3 @ 69 bar Number of strokes of standard 66 cm 3 hand pump per 90 stroke equals 21 1

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09, Page 2 of 11, Rev. 1 November 2017 3/8 N PTF PO RTS 17.78 27.31 25.08 29.85 9 x 7 Rotary Vane Actuator Torque expression: 118.06 Nm/bar Maximum test pressure: 206.8 bar Maximum acceptable valve stem: 9.53 cm. diameter Maximum wrench square: 6.35 cm. across flats Weight of actuator including hydraulic fluid: 104.3 kg. Actual fluid displacement per 90 stroke equals 2.05 L Gas consumption per 90 stroke equals 0.4 standard m 3 @ 69 bar Number of strokes of standard 66 cm 3 hand pump per 90 stroke equals 32 3/8 N PTF PO RTS 17.78 41.28 39.05 29.85 9 x 12 Rotary Vane Actuator Torque expression: 210.72 Nm/bar Maximum test pressure: 206.8 bar Maximum acceptable valve stem: 9.53 cm. diameter Maximum wrench square: 6.35 cm. across flats Weight of actuator including hydraulic fluid: 157.4 kg. Actual fluid displacement per 90 stroke equals 3.7 L Gas consumption per 90 stroke equals 0.6 standard m 3 @ 69 bar Number of strokes of standard 66 cm 3 hand pump per 90 stroke equals 57 23.5 1/2 NPTF PORTS (shown plugged) 31.8 11.43 11.43 39.69 12 1/2 x 8 Rotary Vane Actuator Torque expression: 306 Nm/bar Maximum working pressure: 103 bar Maximum test pressure: 199 bar Maximum acceptable valve stem: 11.43 cm. diameter Weight of actuator including hydraulic fluid: 226.8 kg. Actual fluid displacement per 90 stroke equals 5.36 L Gas consumption per 90 stroke equals 0.92 standard m 3 @ 69 bar Number of strokes of standard 66 cm 3 hand pump per 90 stroke equals 82 2

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 3 of 11, Rev. 1 1/2 N PTF PO RTS (show n plugged) 11.43 11.43 12 1/2 x 12 Rotary Vane Actuator Torque expression: 472.28 Nm/bar Maximum test pressure: 198.6 bar 40.64 Maximum acceptable valve stem: 11.43 cm. diameter 23.5 39.69 Maximum wrench square: 8.26 cm. across flats Weight of actuator including hydraulic fluid: 299.4 kg. Actual fluid displacement per 90 stroke equals 8.03 L Gas consumption per 90 stroke equals 1.4 standard m 3 @ 69 bar Number of strokes of standard 66 cm 3 hand pump per 90 stroke equals 123 26.35 1/2 NPTF PORTS (shown plugged) 52.23 14.61 14.61 46.36 14 1/2 x 16 Rotary Vane Actuator Torque expression: 855.32 Nm/bar Maximum working pressure: 103 bar Maximum test pressure: 190 bar Maximum acceptable valve stem: 13.97 cm. diameter Weight of actuator including hydraulic fluid: 483 kg. Actual fluid displacement per 90 stroke equals 14.96 L Gas consumption per 90 stroke equals 2.58 standard m 3 @ 69 bar Number of strokes of standard 197 cm 3 hand pump per 90 stroke equals 76 16 1/2 x 16 Rotary Vane Actuator Torque expression: 1129.02 Nm/bar 1/2"N PTF PO RTS (show n plugged) 15.40 15.40 Maximum test pressure: 148.9 bar 54.77 Maximum acceptable valve stem: 15.24 cm. diameter 29.21 Weight of actuator including hydraulic fluid: 601 kg. 50.17 Actual fluid displacement per 90 stroke equals 20.98 L Gas consumption per 90 stroke equals 3.6 standard m 3 @ 69 bar Number of strokes of standard 197 cm 3 hand pump per 90 stroke equals 107 3

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09, Page 4 of 11, Rev. 1 November 2017 3/4"N PTF PO RTS (show n plugged) 17.78 17.78 20 x 16 Rotary Vane Actuator Torque expression: 1883.18 Nm/bar Maximum test pressure: 155.1 bar 53.98 Maximum acceptable valve stem: 15.24 cm. diameter 34.93 61.60 Weight of actuator including hydraulic fluid: 852.8 kg. Actual fluid displacement per 90 stroke equals 32.98 L Gas consumption per 90 stroke equals 5.7 standard m 3 @ 69 bar Number of strokes of standard 197 cm 3 hand pump per 90 stroke equals 168 3/4"N PTF PO RTS (show n plugged) 58.58 20.96 20.96 25 x 16 Rotary Vane Actuator Torque expression: 3038.78 Nm/bar Maximum test pressure: 148.9 bar 42.55 76.20 Maximum acceptable valve stem: 16.51 cm. diameter Weight of actuator including hydraulic fluid: 1324.5 kg. Actual fluid displacement per 90 stroke equals 52.96 L Gas consumption per 90 stroke equals 9.1 standard m 3 @ 69 bar Number of strokes of standard 197 cm 3 hand pump per 90 stroke equals 270 ¾ "N PTF PO RTS (show n plugged) 20.32 20.32 26 x 22 Rotary Vane Actuator Torque expression: 4413.63 Nm/bar Maximum test pressure: 148.9 bar 44.45 76.68 78.74 Maximum acceptable valve stem: 18.73 cm. diameter Weight of actuator including hydraulic fluid: 1837 kg. Actual fluid displacement per 90 stroke equals 76.98 L Gas consumption per 90 stroke equals 13.3 standard m 3 @ 69 bar Number of strokes of standard 197 cm 3 hand pump per 90 stroke equals 392 4

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 5 of 11, Rev. 1 44.45 ¾ "N PTF PO RTS (show n plugged) 111.92 20.32 20.32 78.74 26 x 36 Rotary Vane Actuator Torque expression: 7113.63 Nm/bar Maximum working pressure: 68.9 bar Maximum test pressure: 137.9 bar Maximum acceptable valve stem: 18.73 cm. diameter Weight of actuator including hydraulic fluid: 3486.8 kg. Actual fluid displacement per 90 stroke equals 126 L Gas consumption per 90 stroke equals 21.7 standard m 3 @ 69 bar Number of strokes of standard 197 cm 3 hand pump per 90 stroke equals 641 54.61 1¼ "N PTF PO RTS (show n plugged) 25.40 25.40 101.76 99.06 33 x 32 Rotary Vane Actuator Torque expression: 9622.58 Nm/bar Maximum working pressure: 68.9 bar Maximum test pressure: 103.4 bar Maximum acceptable valve stem: 24.13 cm. diameter Weight of actuator including hydraulic fluid: 4037 kg. Actual fluid displacement per 90 stroke equals 178 L Gas consumption per 90 stroke equals 29.7 standard m 3 @ 69 bar Number of strokes of standard 197 cm 3 hand pump per 90 stroke equals 905 5

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09, Page 6 of 11, Rev. 1 November 2017 Speed of Operation in Seconds Per 90 Rotation* Actuator Operating Pressure (bar) Size 7 14 21 28 35 41 48 55 62 69 76 83 90 97 6 1/2 x 2 8 5 4 4 3 3 3 2 2 2 2 2 1 1 6 1/2 x 3 1/2 9 6 5 5 4 3 3 3 2 2 2 2 1 1 6 1/2 x 8 10 7 6 6 5 4 4 4 3 ½ 3 ½ 3 3 2 1 9 x 7 14 11 9 8 8 7 5 5 5 3 3 3 2 2 9 x 12 15 13 11 10 9 9 8 7 6 6 5 4 4 3 12 1/2 x 8 15 14 12 11 11 10 9 9 8 8 7 6 6 6 12 1/2 x 12 20 18 18 16 15 13 10 10 10 10 9 9 9 9 14 1/2 x 16 32 25 20 18 16 14 14 12 12 12 12 11 11 11 16 1/2 x 16 40 30 28 23 20 19 17 16 15 15 15 15 15 14 20 x 16 40 35 30 25 24 22 20 20 20 19 19 19 19 18 25 x 16 76 53 43 37 33 30 25 25 24 24 24 24 22 22 26 x 22 80 60 50 40 35 30 25 25 25 25 25 25 25 25 26 x 36 90 80 70 50 45 40 38 35 35 35 33 x 32 254 178 146 125 111 102 95 88 83 79 * Stroking speeds above are approximate as speed may be affected by fluid viscosity or the flow capacities of the individual control components. The listed speeds are based on actuators with gas hydraulic tanks, hand pump and the standard poppet type control block in the power supply circuit. Adjustable speed control valves may be specified so that the stroking speed may be fine tuned to the field operating conditions. If faster speeds are required, please consult a factory representative. Approximate Weights For Shafer Rotary Operators,Hydraulic Tanks And Power Storage Tanks Size Operator Weight (kg) Hydraulic Tank Weight (kg) (per Pair) Power Storage Tank (Standard) Weight (kg) 6 1/2 x 2 18 16 9 6 1/2 x 3 1/2 45 16 9 6 1/2 x 8 68 34 18 9 x 7 125 50 24 9 x 12 181 77 39 12 1/2 x 8 227 120 57 12 1/2 x 12 299 184 79 14 1/2 x 16 484 307 125 16 1/2 x 16 601 397 204 20 x 16 853 578 314 25 x 16 1325 1229 536 26 x 22 204 1519 658 26 x 36 3488 2433 1050 33 x 32 4038 3379 1434 6

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 7 of 11, Rev. 1 Approximate Weights For Shafer Hand Pumps, 2-Way Electric Controls and Limit Switches Pumps Control (Two-Way Electric) Limit Switch 4 in. = 9 kg 1/4 in. = 27 kg LARGE = 12 kg 12 in. = 20 kg. 1/2 in. = 34 kg --- 4" Pump, 1/4 Poppet Block = 24 kg + Cover 13 kg = Total 37 kg 12" Pump, 1/4 Poppet Block= 46 kg + Cover 19 kg = Total 65 kg Linebreak Small Plate with Lockout = 19 kg + Cover 10 kg = 29 kg 4" Pump / D.H.V. = 23 kg 12" Pump / D.H.V. = 50 kg Limit Valve (ESD) with Plate 5 kg. 1-08672 Terminal Box= 5 kg. 1-09027 Terminal Box = 6 kg. 1/4 Poppet Block, 4 cu. in. Pump & Linebreak with cover = 43 kg. 7

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09, Page 8 of 11, Rev. 1 November 2017 Dimensional Data Gas / Hydraulic Rotary Vane - Horizontal Stem, Vertical Line Note: All dimensional data is for reference only and subject to change. Depending on the application, specific actuator controls may or may not be located inside of the control box. Where specified, there may be additional pressure vessels or power storage tanks which are not shown. Size A B C D E F G H J K L M 6 1/2 x 2 13.34 62.23 73.66 59.69 64.14 46.36 48.90 41.28 22.23 23.50 1.27 5.72 6 1/2 x 3 1/2 17.15 62.23 73.66 59.06 64.14 46.36 48.90 41.28 22.23 23.50 1.27 9.53 6 1/2 x 8 28.58 62.23 73.66 76.20 64.14 46.36 48.90 41.28 22.23 23.50 12.07 16.51 9 x 7 27.31 75.57 90.17 78.11 64.14 53.98 48.90 53.98 29.85 27.31 10.80 13.97 9 x 12 41.28 77.47 92.08 95.25 64.14 59.06 48.90 55.88 29.85 29.85 19.05 27.94 12 1/2 x 8 31.75 82.55 99.70 114.94 64.14 59.06 48.90 60.96 40.01 29.85 29.21 19.05 12 1/2 x 12 43.18 85.73 105.41 106.68 64.14 69.22 48.90 64.14 40.01 31.12 25.40 27.31 14 1/2 x 16 52.23 113.03 135.89 119.38 82.55 85.09 58.42 81.28 46.36 41.28 17.78 23.50 16 1/2 x 16 57.15 116.21 141.61 153.04 82.55 85.09 58.42 85.09 50.17 41.28 33.66 27.31 20 x 16 59.06 125.73 156.21 147.32 82.55 101.60 58.42 93.98 61.60 44.45 31.12 26.67 25 x 16 62.87 130.18 168.28 172.09 81.92 111.76 64.14 95.25 76.20 29.21 43.82 26.67 26 x 22 81.92 * * * 81.92 * 64.14 * 78.74 * * * 26 x 36 115.57 * * * 81.92 * 64.14 * 78.74 * * * 33 x 32 104.78 * * * 81.92 * 64.14 * 99.06 * * * * Indicates this particulat size of actuator has not been used in this type of application. All dimensions shown in centimeters. H F/2 G /2 M A F G AC TUATO R AP P R OXIMATE OVE R AL L C O N TR O L G AS/H YDRAU LIC TAN K ASSEM BLY D E J- D IAM ETER C LO SE L OP E N K B C APPRO XIM ATE O VER ALL 8

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 9 of 11, Rev. 1 Gas / Hydraulic Rotary Vane - Vertical Stem, Horizontal Line Note: All dimensional data is for reference only and subject to change. Depending on the application, specific actuator controls may or may not be located inside of the control box. Where specified, there may be additional pressure vessels or power storage tanks which are not shown. Size A B C D E F G H J K 6 1/2 x 2 13.34 62.23 72.39 59.06 64.14 46.36 48.90 40.01 22.23 1.27 6 1/2 x 3 1/2 17.15 61.60 72.39 59.06 64.14 46.36 48.90 40.01 22.23 1.27 6 1/2 x 8 28.58 61.60 72.39 76.20 64.14 46.36 48.90 40.01 22.23 12.07 9 x 7 27.31 69.85 85.09 78.11 64.14 53.98 48.90 48.90 29.85 10.80 9 x 12 41.28 72.39 87.00 95.25 64.14 59.06 48.90 50.80 29.85 19.05 12 1/2 x 8 31.75 81.28 100.97 114.94 64.14 59.06 48.90 59.69 40.01 22.86 12 1/2 x 12 43.18 81.28 100.97 106.68 64.14 69.22 48.90 59.69 40.01 25.40 14 1/2 x 16 52.23 98.43 121.29 119.38 82.55 85.09 58.42 66.68 46.36 17.78 16 1/2 x 16 57.15 101.60 127.00 153.04 82.55 85.09 58.42 70.49 50.17 33.66 20 x 16 59.06 112.40 142.88 147.32 82.55 101.60 58.42 80.65 61.60 31.12 25 x 16 62.23 129.54 167.64 172.09 92.71 111.76 64.14 92.71 76.20 34.29 26 x 22 81.28 93.98 172.72 214.00 92.71 121.92 64.14 96.52 78.74 55.25 26 x 36 114.94 147.32 186.69 176.53 92.71 144.78 64.14 110.49 78.74 33.66 33 x 32 104.78 158.12 207.65 247.65 93.35 144.78 64.14 121.29 99.06 71.76 * Indicates this particulat size of actuator has not been used in this type of application. All dimensions shown in centimeters. H A P P R O X IM A T E F O VE R AL L F/2 G/2 CLOSE J - DIAMETER G OP E N CONTR OL GAS/HYDRA ULIC TANK ASSEMBL Y A P P R O X IM A T E O VE R AL L E D ACTU AT OR A K M B C APPR OXIMATE OVERALL 9

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09, Page 10 of 11, Rev. 1 November 2017 Central Hydraulic System - Horizontal Stem, Vertical Line Note: All dimensional data is for reference only and subject to change. Depending on the application, specific actuator controls may or may not be located inside of the control box. Where specified, there may be additional pressure vessels or power storage tanks which are not shown. Size A B C D E F G H J K L M 6 1/2 x 2 13.34 59.69 68.58 78.11 57.79 55.88 48.90 43.18 22.23 31.75 11.43 5.72 6 1/2 x 3 1/2 17.15 62.87 73.66 78.11 57.79 55.88 48.90 43.18 22.23 31.75 11.43 9.53 6 1/2 x 8 28.58 62.87 73.66 78.11 57.79 55.88 48.90 43.18 22.23 31.75 11.43 16.51 9 x 7 27.31 66.68 81.28 80.01 57.79 55.88 48.90 46.99 29.85 31.75 12.70 13.34 9 x 12 41.28 66.68 81.28 80.01 57.79 57.15 48.90 46.99 29.85 31.75 12.70 27.31 12 1/2 x 8 31.75 71.12 91.44 82.55 57.79 59.06 48.90 52.07 40.01 31.75 12.70 22.23 12 1/2 x 12 43.18 71.12 91.44 85.09 57.79 59.06 48.90 52.07 40.01 31.75 12.70 27.31 14 1/2 x 16 52.22 87.00 109.86 88.27 82.55 67.31 71.76 59.06 46.36 31.75 22.86 23.50 16 1/2 x 16 57.15 88.90 114.30 90.17 82.55 67.31 71.76 60.96 50.17 31.75 22.86 27.31 20 x 16 59.06 95.25 126.37 95.89 82.55 67.31 71.76 67.31 61.60 31.75 22.86 26.67 25 x 16 62.23 93.35 131.45 116.84 92.71 63.50 64.14 73.03 76.20 31.75 13.97 31.12 26 x 22 81.28 * * * 92.71 * 64.14 0.00 78.74 * * * 26 x 36 114.94 * * * 92.71 * 64.14 0.00 78.74 * * * 33 x 32 104.78 * * * 92.71 * 64.14 0.00 99.06 * * * * Indicates this particulat size of actuator has not been used in this type of application. All dimensions shown in centimeters. AP P R OXIMATE F OVE RALL G M A K G /2 ACTUATO R C O N TR O L RESERVO IR TAN K AP P R OXIMATE OVE RALL E J -D IAM ETER L B H CUSTO M ER C O NNEC TIO N C APPRO XIM ATE O VER ALL 10

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 11 of 11, Rev. 1 Central Hydraulic System - Vertical Stem, Horizontal Line Note: All dimensional data is for reference only and subject to change. Depending on the application, specific actuator controls may or may not be located inside of the control box. Where specified, there may be additional pressure vessels or power storage tanks which are not shown. Size A B C D E F G H J K L 6 1/2 x 2 13.34 62.87 73.66 76.84 57.79 55.88 48.90 43.18 22.23 31.75 1.27 6 1/2 x 3 1/2 17.15 62.87 73.66 80.65 57.79 55.88 48.90 43.18 22.23 31.75 2.54 6 1/2 x 8 28.58 62.87 73.66 87.63 57.79 55.88 48.90 43.18 22.23 31.75 9.53 9 x 7 27.31 66.04 81.28 83.82 57.79 55.88 48.90 46.99 29.85 31.75 6.35 9 x 12 41.28 66.04 81.28 97.79 57.79 55.88 48.90 46.99 29.85 31.75 20.32 12 1/2 x 8 31.75 69.22 86.36 87.63 57.79 55.88 48.90 49.53 40.01 31.75 3.81 12 1/2 x 12 43.18 71.76 91.44 97.79 57.79 55.88 48.90 52.71 40.01 31.75 19.69 14 1/2 x 16 52.22 87.00 109.86 102.87 82.55 67.31 71.76 59.06 46.36 31.75 10.16 16 1/2 x 16 57.15 88.90 114.30 104.14 82.55 67.31 71.76 60.96 50.17 31.75 16.51 20 x 16 59.06 95.25 126.37 103.51 82.55 67.31 71.76 67.31 61.60 31.75 15.24 25 x 16 62.23 93.35 131.45 128.91 92.71 63.50 64.14 72.39 76.20 31.75 36.20 26 x 22 81.28 94.62 133.99 135.26 92.71 63.50 64.14 73.03 78.74 31.75 42.55 26 x 36 114.94 * * * 92.71 * 64.14 * * * * 33 x 32 104.78 * * * 92.71 * 64.14 * * * * * Indicates this particulat size of actuator has not been used in this type of application. All dimensions shown in centimeters. AP P R OXIMATE OVE RALL G F K G /2 J -D IAM ETER AP P R OXIMATE OVE RALL CONTR OL RESERVO IR TAN K D E ACTUATO R A L B H CUSTO M ER C O NNEC TIO N C APPRO XIM ATE O VER ALL 11

World Area Configuration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers. Choose the WACC or sales office nearest you: NORTH & SOUTH AMERICA 19200 Northwest Freeway Houston TX 77065 USA T +1 281 477 4100 F +1 281 477 2809 2500 Park Avenue West Mansfield Ohio 44906 USA T +419 529 4311 F +419 529 3688 MIDDLE EAST & AFRICA P. O. Box 17033 Dubai United Arab Emirates T +971 4 811 8100 F +971 4 886 5465 P. O. Box 10305 Jubail 31961 Saudi Arabia T +966 3 340 8650 F +966 3 340 8790 Av. Hollingsworth 325 Iporanga Sorocaba SP 18087-105 Brazil T +55 15 3238 3788 F +55 15 3228 3300 ASIA PACIFIC No. 9 Gul Road #01-02 Singapore 629361 T +65 6777 8211 F +65 6268 0028 No. 1 Lai Yuan Road Wuqing Development Area Tianjin 301700 P. R. China T +86 22 8212 3300 F +86 22 8212 3308 24 Angus Crescent Longmeadow Business Estate East P.O. Box 6908 Greenstone 1616 Modderfontein Extension 5 South Africa T +27 11 451 3700 F +27 11 451 3800 EUROPE Berenyi u. 72-100 Videoton Industry Park Building #230 Székesfehérvár 8000 Hungary T +36 22 53 0950 F +36 22 54 3700 For complete list of sales and manufacturing sites, please visit www.emerson.com/actuationtechnologieslocations or contact us at info.actuationtechnologies@emerson.com www.emerson.com/shafer 2017 Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Shafer TM is a mark of one of the Emerson family of companies. All other marks are property of their respective owners. The contents of this publication are presented for information purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.