Free Float Air Trap G8

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8

Float Dynamic Steam Trap J10

Bypass Blowdown Steam Trap BT3N / MBT3N / PBT3N

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference BALANCED PRESSURE THERMOSTATIC STEAM TRAPS LV SERIES

Surplussing Valve SP-COSR-16

CV-COSR. Pneumatic Control Valve. Copyright 2013 by TLV CO., LTD. All rights reserved

Bypass Blowdown Steam Trap (Free Float Steam Trap with X-element) J3S-X-BV / J3S-X-PB / J3S-X-MB

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference THERMODYNAMIC STEAM TRAPS HR-A SERIES HR150A.

Pneumatic Control Valve for Steam PN-COSR-16

GT5C. Copyright 2014 by TLV CO., LTD. All rights reserved MA-01 (GT5C PowerTrap) 16 October 2014 ISO 9001/ ISO

GP5C. Copyright 2016 by TLV CO., LTD. All rights reserved MA-01 (GP5C PowerTrap) 23 August 2016 ISO 9001/ ISO

High-precision Multi-control Valve for Steam COSPECT MC-COS-3/MC-COS-16

MA-04 (GP10/GT10/GP14/GT14 PowerTrap) 1 February 2019 GP10/GT10 GP14/GT14. Copyright 2019 by TLV CO., LTD. All rights reserved

Motorized Pressure Reducing Valve for Steam COSPECT M-COS-3 / M-COS-16 / M-COS-21

MA-03 (GP10/GT10/GP14/GT14 PowerTrap) 28 January 2015 ISO 9001/ ISO GP10/GT10 GP14/GT14

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference. PRESSURE REDUCING VALVES FOR STEAM COS/COSR Series.

M-COSR-3 / M-COSR-16 / M-COSR-21

3M TM Filter Housing 1BS-T/1BS-TW Series

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

GP10L/GT10L GP14L/GT14L GP14M/GT14M

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

PowerTrap Manufacturer Kakogawa, Japan GP10L/GT10L

Pamphlet M0000. Three-in-One Pressure Regulator, Separator, and Steam Trap COSPECTR PRESSURE REDUCING VALVES

ESE Series Cast Iron Sewage Pumps

3-Way Ball Valve Type 23H

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

MC-COSR-3/MC-COSR-16

Disassembly / Reassembly Procedure

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

SUNC3000 / Item #40885

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

Installation Manual DIAPHRAGM WELL TANK

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

VDF (Vortex Dynamic Filter) Instruction Manual CL-MR-series models

APCO CSV-1600 SURGE CHECK VALVE

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

ACTIVAL Two-way Ball Valve with Threaded-end Connection

CSA products for waste water. Combination air valve. Mod. SCF 2

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

PL Submersible, Semi-Vortex, Water Feature Pump

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

ENGINE LUBRICATION & COOLING SYSTEMS SECTIONLC CONTENTS. ENGINE LUBRICATION SYSTEM...2 Precautions...2

MODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Matala. VersiFlow Series. Instruction and Maintenance Manual

GP-2000 : Trouble Shooting. Cause of problems

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

OPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction

Viscount I Hydraulic Motor and Displacement Pump

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

Thank you for selecting the GD submersible grinder pump.

Read and understand this manual for safely usage.

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Pressurized oil drain for collection of used lubricants and anti-freeze.

Horizontal Hydraulic Driver

HALLMARK INDUSTRIES INC

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

Owner s Manual GLASSLINED PUMP TANK

CSA products for waste water. Anti water hammer combination air valve. Mod. SCF-RFP

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

Operating manual Separator

PT-516 Pumping Trap Installation and Maintenance

Sediment strainer (Type Y)

Self-Priming Centrifugal Pumps

Butterfly valves Figure 56 Installation & Maintenance Instructions

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

Pump Operating and Maintenance Manual - Models

TECHNICAL SERVICE MANUAL

SUBMERSIBLE SUMP PUMPS

StormPro BA Series Sump Pump

MAINTENANCE NOTE: ANY LEAK FROM THE MAIN BODY OF THE LOAD IS AN INDICATION THAT THE UNIT SHOULD BE RETURNED TO THE FACTORY FOR REPAIRS.

6 and 8 HAIR AND LINT STRAINERS

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps Series

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

PIN TYPE FORK POSITIONER WITH SHIFTING SF-F MODEL

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

MetroPrime 22MPC Self-Priming Centrifugal Pump

ACF Operation Manual

4 - Way Control 4 - Way Control 4 - Way Control with lock

Butterfly Valve Type 57P

ENGINE COOLING SYSTEM

KEYSTONE. Check valves Figure 85/86 Installation & Maintenance Instructions. Figure 85. Figure 86.

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Telescopic Transmission Jacks

Battery Powered Hydraulic Pump; Kit PN [ ]

Transcription:

ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Cyclone Separator Trap DC5S Copyright 2015 by TLV Co., Ltd. All rights reserved

1 Contents Introduction... 1 Safety Considerations... 2 Specifications... 4 Configuration... 5 Installation... 6 Maintenance... 7 Disassembly / Reassembly... 8 Troubleshooting... 10 Product Warranty... 11 Introduction Thank you for purchasing the Cyclone Separator Trap. This product has been thoroughly inspected before being shipped from the factory. When the separator trap is delivered, before doing anything else, check the specifications and external appearance to make sure nothing is out of the ordinary. Also be sure to read this manual carefully before use and follow the instructions to be sure of using the separator trap properly. For use on steam mains and branches, the Cyclone Separator Traps use centrifugal force to separate condensate from steam, and feature a built-in free float steam trap for the automatic discharge of the collected condensate. If detailed instructions for special order specifications or options not contained in this manual are required, please contact for full details. This instruction manual is for the models listed on the front cover. It is needed not only for installation but for subsequent maintenance, disassembly/ reassembly and troubleshooting. Please keep it in a safe place for future reference.

2 Safety Considerations Read this section carefully before use and be sure to follow the instructions. Installation, inspection, maintenance, repairs, disassembly, adjustment and valve opening/closing should be carried out only by trained maintenance personnel. The precautions listed in this manual are designed to ensure safety and prevent equipment damage and personal injury. For situations that may occur as a result of erroneous handling, three different types of cautionary items are used to indicate the degree of urgency and the scale of potential damage and danger: DANGER, WARNING and. The three types of cautionary items above are very important for safety: be sure to observe all of them as they relate to installation, use, maintenance, and repair. Furthermore, TLV accepts no responsibility for any accidents or damage occurring as a result of failure to observe these precautions. Symbols Indicates a DANGER, WARNING or item. DANGER Indicates an urgent situation which poses a threat of death or serious injury WARNING Indicates that there is a potential threat of death or serious injury Indicates that there is a possibility of injury or equipment / product damage WARNING NEVER apply direct heat to the float. The float may explode due to increased internal pressure, causing accidents leading to serious injury or damage to property and equipment. Install properly and DO NOT use this product outside the recommended operating pressure, temperature and other specification ranges. Improper use may result in such hazards as damage to the product or malfunctions that may lead to serious accidents. Local regulations may restrict the use of this product to below the conditions quoted. DO NOT use this product in excess of the maximum operating pressure differential. Such use could make discharge impossible (blocked). Take measures to prevent people from coming into direct contact with product outlets. Failure to do so may result in burns or other injury from the discharge of fluids. Safety cautions continued on next page.

3 When disassembling or removing the product, wait until the internal pressure equals atmospheric pressure and the surface of the product has cooled to room temperature. Disassembling or removing the product when it is hot or under pressure may lead to discharge of fluids, causing burns, other injuries or damage. Be sure to use only the recommended components when repairing the product, and NEVER attempt to modify the product in any way. Failure to observe these precautions may result in damage to the product and burns or other injury due to malfunction or the discharge of fluids. Do not use excessive force when connecting threaded pipes to the product. Over-tightening may cause breakage leading to fluid discharge, which may cause burns or other injury. Use only under conditions in which no freeze-up will occur. Freezing may damage the product, leading to fluid discharge, which may cause burns or other injury. Use only under conditions in which no water hammer will occur. The impact of water hammer may damage the product, leading to fluid discharge, which may cause burns or other injury.

4 Specifications Install properly and DO NOT use this product outside the recommended operating pressure, temperature and other specification ranges. Improper use may result in such hazards as damage to the product or malfunctions which may lead to serious accidents. Local regulations may restrict the use of this product to below the conditions quoted. DO NOT use this product in excess of the maximum operating pressure differential; such use could make discharge impossible (blocked). Use only under conditions in which no freeze-up will occur. Freezing may damage the product, leading to fluid discharge, which may cause burns or other injury. Refer to the product nameplate for detailed specifications. Nominal Diameter Valve No.** Maximum Allowable Pressure* Maximum Operating Temperature Model Production Lot No. Maximum Allowable Temperature (TMA)* Maximum Differential Pressure * Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are PRESSURE SHELL DESIGN CONDITIONS, NOT OPERATING CONDITIONS. ** Valve No. is displayed for products with options. This item is omitted from the nameplate when there are no options.

5 Configuration NO. Name NO. Name 1 Body 10 Float 2 Separator Body 11 Guide Pin 3 Trap Cover 12 Body Gasket 4 Float Cover 13 Wave Spring 5 Separator 14 Screen 6 Trap Valve Seat 15 Trap Cover Bolt 7 Valve Seat Gasket 16 Lower Plug 8 Bushing 17 Nameplate 9 Trap Cover Gasket 18 Upper Plug (Option)

6 Installation Install properly and DO NOT use this product outside the recommended operating pressure, temperature and other specification ranges. Improper use may result in such hazards as damage to the product or malfunctions which may lead to serious accidents. Local regulations may restrict the use of this product to below the conditions quoted. Take measures to prevent people from coming into direct contact with product outlets. Failure to do so may result in burns or other injury from the discharge of fluids. Do not use excessive force when connecting threaded pipes to the product. Over-tightening may cause breakage leading to fluid discharge, which may cause burns or other injury. 1. Before installation, be sure to remove all protective seals from the product. 2. Before installing the separator trap, blow out the inlet piping to remove any piping scraps, dirt and oil. Close the inlet valve after blowdown. 3. Install the separator trap at the point on the piping where the separation of condensate will have the greatest effect on efficiency. For example, on a steam main or branch at the inlet of equipment requiring high-quality dry steam. 4. Install the separator trap so the arrow on the product is pointing in the direction of steam flow. 5. The separator trap should be inclined no more than 10 horizontally and front-toback. 6. To facilitate inspection and maintenance, install a union at the trap outlet and ensure that there is sufficient space for maintenance. 7. Open the inlet valve and check to make sure that the separator trap functions properly. If there is a problem, determine the cause by using the Troubleshooting guide in this manual. Tolerance Angle for Installation - 10 Make sure the trap is installed with the raised lettering on the body horizontal.

7 Maintenance Take measures to prevent people from coming into direct contact with product outlets. Failure to do so may result in burns or other injury from the discharge of fluids. Be sure to use only the recommended components when repairing the product, and NEVER attempt to modify the product in any way. Failure to observe these precautions may result in damage to the product or burns or other injury due to malfunction or the discharge of fluids. Operational Check A visual inspection of the following items should be done on a daily basis to determine whether the separator trap is operating properly or has failed. Periodically (at least biannually) the operation should also be checked by using diagnostic equipment, such as a stethoscope or thermometer. (Installation, inspection, maintenance, repairs, disassembly, adjustment and valve opening/closing should be carried out only by trained maintenance personnel.) Check to see if steam is flowing from the separator outlet. Check all flow meters and check the differential pressure. If there is insufficient flow or differential pressure is too large, disassemble and check for clogging of the screen. If the built-in steam trap should fail, it may cause damage to piping and equipment, resulting in faulty or low quality products or losses due to steam leakage. (Steam Trap Operational Check) Normal : Condensate, is discharged continuously from the trap outlet with flash steam and the sound of flow can be heard. If there is very little condensate, there is almost no sound of flow. Blocked (Discharge Impossible) : No condensate is discharged from the trap outlet. The trap is quiet and makes no noise, and the surface temperature of the trap is low. Blowing Steam Leakage : Live steam continuously flows from the trap outlet and there is a continuous metallic sound. : Live steam is discharged through the trap outlet together with the condensate and there is a high-pitched sound. Parts Inspection When parts have been removed, or during periodic inspections, use the following table to inspect the parts and replace any that are found to be defective. Procedure Body Interior: Check for the build-up Screen: Check for clogging or corrosion Gaskets: Check for warping or damage Float: Check for scratches or dents Trap Valve Seat: Check for the wear or scratches

8 Disassembly / Reassembly WARNING NEVER apply direct heat to the float. The float may explode due to increased internal pressure, causing accidents leading to serious injury or damage to property and equipment. When disassembling or removing the product, wait until the internal pressure equals atmospheric pressure and the surface of the product has cooled to room temperature. Disassembling or removing the product when it is hot or under pressure may lead to discharge of fluids, causing burns, other injuries or damage. Use the following procedures to remove components. Use the same procedures in reverse to reassemble. (Installation, inspection, maintenance, repairs, disassembly, adjustment and valve opening/closing should be carried out only by trained maintenance personnel.) Removing / Reattaching the Trap Cover Part During Disassembly During Reassembly Trap Cover Bolt Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque Trap Cover Remove the trap cover by pulling Remove any remaining pieces of old it down, being careful not to scratch the seating surface gasket; reattach using the guide pin to aid alignment Trap Cover Gasket Remove, being careful not to scratch the surfaces Removing / Reinserting Parts inside the Trap Cover Replace with new a gasket if damaged Part During Disassembly During Reassembly Float Cover Remove the cover by lift it Using the guide pin, align the separator upward body with the body Float Trap Valve Seat Valve Seat Gasket As the float is precision ground, be careful not to scratch its surface Remove with a socket wrench Remove, being careful not to scratch the surfaces Separating / Reattaching Body and Separator Body As the float is precision ground, be careful not to scratch its surface Consult the table of tightening torques and tighten to the proper torque Replace with a new gasket if damaged Part During Disassembly During Reassembly Body Bolt Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque Separator Body Detach the separator body from the body, being careful not to let the separator fall Separator Remove when detaching the separator body from the body Using the guide pin, align the separator body with the body Insert into the groove in separator body Screen Be careful not to bend Place on top of the separator, being careful not to bend Wave Spring Remove from its groove Insert into the groove in separator body Body Gasket Be careful not to scratch the surfaces Replace with a new gasket if damaged

9 Removing/Reattaching the Plug (usually no need to disassemble or reassemble) Lower Plug (for drain) Part During Disassembly During Reassembly Upper Plug* (for blow) Exploded View Remove with a socket wrench Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque Consult the table of tightening torques and tighten to the proper torque *Optional Body Upper Plug (Option) Screen Separator Wave Spring Body Gasket Separator Body Body Bolt Guide Pin Float Cover Float Trap Valve Seat Valve Seat Gasket Trap Cover Bolt Trap Cover Gasket Guide Pin Trap Cover Lower Plug

10 Table of Tightening Torques Part Name Distance Across Flats Torque mm (in) N m (lbf ft) Body Bolt Trap Cover Bolt 13 ( 1 / 2 ) 30 (22) Trap Valve Seat 11 ( 7 / 16 ) 10 (7) Plug (Upper / Lower)* 9 ( 11 / 32 ) 5** (4)** NOTE: -Coat all threaded portions with anti-seize. (N m 10 kg cm) -If drawings or other special documentation were supplied for the product, any torque given there takes precedence over values shown here. *Upper plug is optional and is not equipped on all products **These values represent tightening torques for threads that are wrapped with 3-3.5 turns of sealing tape. Troubleshooting WARNING NEVER apply direct heat to the float. The float may explode due to increased internal pressure, causing accidents leading to serious injury or damage to property and equipment. When disassembling or removing the product, wait until the internal pressure equals atmospheric pressure and the surface of the product has cooled to room temperature. Disassembling or removing the product when it is hot or under pressure may lead to discharge of fluids, causing burns, other injuries or damage. When the separator trap fails to operate properly, use the following table to locate and remedy the cause. Problem Cause Remedy No condensate is discharged (blocked) or discharge is poor Steam is discharged or leaks from the trap outlet (blowing) (steam leakage) Steam is leaking from sealing surfaces Water is mixed in with the steam from the separator outlet Separator outlet pressure drops or desired flow rate is unachievable The float is damaged or filled with condensate The trap valve seat port, screen or piping is clogged with rust or scale The trap operating pressure exceeds the maximum specified pressure, or there is insufficient pressure differential between the trap inlet and outlet Rust and scale have accumulated around the trap valve seat or beneath the float The trap valve seat is damaged The float is deformed or coated with scale The separator is installed above the maximum allowable inclination Deterioration or damage to gaskets Improper tightening torques were used Replace with a new float Clean parts Compare specifications and actual operating conditions Clean parts Replace with a new trap valve seat Clean or replace with a new float Correct the installation Replace with a new gasket Tighten to the proper torque Steam flow velocity is too high Take steps necessary to lower the steam flow velocity Review causes listed above in No condensate is discharged and follow the appropriate remedy The screen is clogged with rust and scale Clean or replace with a new screen

11 Product Warranty 1. Warranty Period One year following product delivery. 2. Warranty Coverage TLV CO., LTD. warrants this product to the original purchaser to be free from defective materials and workmanship. Under this warranty, the product will be repaired or replaced at our option, without charge for parts or labor. 3. This product warranty will not apply to cosmetic defects, nor to any product whose exterior has been damaged or defaced; nor does it apply in the following cases: 1) Malfunctions due to improper installation, use, handling, etc., by other than TLV CO., LTD. authorized service representatives. 2) Malfunctions due to dirt, scale, rust, etc. 3) Malfunctions due to improper disassembly and reassembly, or inadequate inspection and maintenance by other than TLV CO., LTD. authorized service representatives. 4) Malfunctions due to disasters or forces of nature. 5) Accidents or malfunctions due to any other cause beyond the control of TLV CO., LTD. 4. Under no circumstances will TLV CO., LTD. be liable for consequential economic loss damage or consequential damage to property. For Service or Technical Assistance: * * * * * * * Contact your representative or your regional office. Manufacturer CO., LTD. 881 Nagasuna, Noguchi Kakogawa, Hyogo 675-8511 JAPAN Tel: 81-(0)79-427-1800 Fax: 81-(0)79-422-2277