Prodigy to Encore HD Manual Powder Spray System Upgrade Kit

Similar documents
Encore HD Powder Spray System with Prodigy Pump Cabinet

Encore HD Automatic System Standalone Pump Stand

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

Mobile Powder Spray System Dolly with Hopper for Cable-Fed Systems

Prodigy HDLV Manual System Installation Instructions

One-Gun Add-On Kit For Smart-Coat Controllers

Prodigy Mobile Box Unloader System

Mobile Powder Spray System Dolly with Hopper

Prodigy HDLV Generation II Manual System Installation Instructions

Spray Pressure Control Manifold

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder

55-Gallon Powder Drum Truck

Spray Pressure Control Manifold

CoolWave 2 Phase Control Board and Cable Replacement Kit

Prodigy HDLV Pump Manifold and Circuit Board

Encore HD Mobile Powder Coating System

Prodigy HDLV Generation II Pump Panel

Prodigy HDLV System Troubleshooting - Generation III

Inverted High Pressure Fluid Filters

Air Spray Proportioning Valve

Fluidizing Pickup Tube Kits

Upgrading the Sure Coat Modular Gun Control System

PREVIOUS GENERATION. Encore Manual Powder Spray Gun Trigger Switch Replacement. Introduction. Preparation. Gun Disassembly

Encore Manual Powder Spray Gun Trigger Switch Replacement

TCU Flushing Manifold and RTD Installation

Paint/Solvent/Dump Valve and Flow-Through Valve

Hypertech Speedometer Calibrator Module Installation Instructions. PN Toyota Tundra & Sequoia

Optional Nozzles for Versa-Spray and Versa-Spray II Guns

Electric Vibratory Box Feeder Retrofit Kit

Prodigy HDLV Pump. Customer Product Manual Part A02

Solenoid Valve Installation Kit

Nordson Airless Nozzle Tester

Touch plate serial number. Please save this info here for use later:

Prodigy HDLV Pump Generation III, Pump Manifold and Circuit Board

Vantage Modular Gun Control System

AN-8 Plus Air Spray Gun Solvent-Based to Waterborne Conversion Kit

Rhino SD2/XD2 Electric Container Level Sensors for 125-mm Frames

Encore HD Manual Powder Spray Gun

Sure Coat 90 Degree Spray Extension

Colormax Powder Coating System Color Change Process

Prodigy Automatic Powder Spray Guns

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

Encore Automatic Porcelain Enamel HD Powder Spray Gun

SPRAY RUN-UP CONTROL KIT ( 4-20 ma Version)

Series 3900/M Pump Retrofit Kit

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

Spectrum VT Inline Powder Feed Pump

R11B EN R11A EN. RackCDU. Service Manual. Edition August 2016 Page 1 of 24 V /8

High Flow and 100 PLUS FB Powder Pumps

0 900 psi Pressure-Reducing Diaphragm Regulator

Prodigy Generation II High-Capacity HDLV Powder Transfer Pump

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

Encore HD and XT Manual Powder Spray System Controller

TL UNIVERSAL WIRING GUIDELINE TRCM - J jan18jh

Pro-Swirl Manifold Air Heater

Sure Coat Manual Gun Control Unit

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

Series 3000V Low Level Indicator

Nylon Fluid Regulators

HC-11 Programmer (optional)

TL UNIVERSAL WIRING PROCEDURE

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

CHEMICAL MIXING SYSTEM OPERATING AND INSTALLATION INSTRUCTIONS

L5000 Plus. Installation & Setup Guide

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

Hi-Z USB Wireless. Introduction/Welcome

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

902 Powder Coating Booth

Installation Instructions for Series 3100V Low Level Indicator

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

TS508. QuickStart Guide Registration. This Tool Must Be Registered To Download Free System Updates. 7 8 Captcha code

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

Vacuum Pump ( /-03) SP3. Owner s Manual

Spectrum HD Feed Center

Vantage Individual Powder Spray Gun Controller

Standard and Conical AN Series Air Spray Nozzles

OBSOLETE. RA-16 Rotary Atomizer Upgrade Kit. Instruction Sheet P/N A. 1. Introduction. 2. Disassembly

Dynojet Research, Inc. All Rights Reserved. Air Fuel Ratio Module Installation and User Guide.

CoolWave 2 Transformer T3 and Wire Harness Upgrade Kit

Prodigy Robot Gun. For parts and technical support, call the Finishing Customer Support Center at (800)

INSTALLATION INSTRUCTIONS. Revision 3.1.1

Encore HD Manual Powder Spray System

Description. Rhino SD2/XD2 Type-H Control Modules. S 55-Gallon Drum with Pneumatic Changeover S 55-Gallon Drum with Electric Changeover

CoolWave 2 Transformer T3 and Wire Harness Upgrade Kits

Sure Coat Individual Controllers

Inverted Dual High-Pressure Fluid Filter Assemblies

TIP SHEET Installation instructions for EVO-NIST1 + LC1

FlexJet Carriage Circuit Board (PCB) Replacement

ZT-USB Series User Manual

Getting Started HONDA

Prodigy Powder Port Feed Center

TIP SHEET EVO-CHRT6(d) STAND-ALONE ADD-ON REMOTE STARTER

PCNC 1100 Series 3 (32085) Column and Head Assembly

Conext Configuration Tool

AWARE VEHICLE INTELLIGENCE TM INSTALLATION MANUAL FOR STERLING MODELS

Advanced User Manual

Prodigy Color-on-Demand System Generation III

Transcription:

Instruction Sheet P/N 60780-0 Prodigy to Encore HD Manual Powder Spray System Upgrade Kit WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description The Prodigy to Encore HD manual spray system upgrade kit is used to upgrade your Prodigy manual spray system to the improved design of the Encore HD manual spray system using an existing Prodigy pump cabinet. The upgrade kit is available in single or dual spray system options. Each kit contains an Encore HD controller, Encore HD manual spray gun(s) and related elements for a successful upgrade. Encore HD Powder Spray Gun Encore HD Controller Figure Encore HD Upgrade Kit 0 Nordson Corporation Part 60780-0

Gun Gun Gun Controller Gun Controller Pump Pump Control Panel Pump Pump Adapters Power Switch System Power System Air Fluidizing Air Regulator Powder Hopper Fluidizing Air Figure Typical System Diagram (Dual Pump HDLV Manual System Shown) Installation The following packaged items are included in the upgrade kit: Controller cable Pump control panel kit Pressure switch with wiring harness Electrode air wash manifold assembly Bulkhead assembly Encore HD powder spray gun Hose adaptor kit Encore HD controller Cable ties Part 60780-0 0 Nordson Corporation

7 Controller Cable Installation WARNING: Shut down all power to the system before performing any of these procedures. See Figure for wiring illustration.. Remove existing spray gun(s) and controller(s).. Remove existing network and power cable(s).. Install new cable(s) as described in Figure, item 0. +VDC 8 P PUMP B J PUMP B SOL J J PATT B SOL J PUMP A SOL J 8 PATT A SOL P PUMP A 9 80 6 SW P P CAN OUT WHITE BLUE P6 CAN IN WHITE BLUE W CAN BUS TERM P DC POWER GRAY ORANGE OPEN SW GRAY ORANGE SK 6 L () N () SK BROWN BLUE 6 8 DRAIN DRAIN 7 SINGLE GUN DUAL GUN 9 Figure 0 Wiring Diagram (Two-Gun System Shown). Pump manifold control harness (6mm). Dual pump controller. 60W power supply. Power supply harness. Terminal block 6. Pressure switch (single gun units) 7. Pressure switch (dual gun units) 8. Wiring harness 9. Ground (inside enclosure bottom) 0. Network and power cables. Electrode air wash manifold assembly 0 Nordson Corporation Part 60780-0

Pressure Switch Installation See Figure for pneumatic illustration.. See Detail A. Remove existing tubing () from the atomizing air fitting () on the bottom of the pump manifold ().. Plug the nipple (7) of the pressure switch () into the atomizing air fitting ().. Plug the existing tubing () into the tee (8) of the pressure switch ().. For dual pump units, install second pressure switch at the gun air fitting as shown in Detail B, plugging the nipple into the gun air fitting and then plugging the existing 6mm tubing into the tee on the pressure switch. ~ ~ ~ ~ ~ ~ A 8 REGULATOR ASSEMBLY 7 A Pressure Switch Installation B AUX AUX 6 GUN AIR GUN AIR Figure Pneumatic Schematic (Two-Gun System Shown). Pump manifold (bottom view). Atomizing air fitting. Pressure switch. Bulkhead assembly. 6mm tubing (existing) 6. Electrode air wash manifold assembly 7. Nipple 8. Male branch tee fitting Part 60780-0 0 Nordson Corporation

Electrode Air Wash Manifold Assembly Installation See Figure for component illustration.. Remove the existing tubing () from the regulator () positioned second from the bottom in the Prodigy pump cabinet.. Install the short piece of tubing from the manifold assembly tee () into the regulator ().. Install the existing tubing from step into the open port of the manifold assembly tee ().. Make sure the bottom of the cabinet is clean and free from dust or oil.. Peel the release tape from the bottom of the manifold assembly (). 6. Position the valve assembly on the bottom of the cabinet in the position shown. Press down to adhere. NOTE: See Figure for pneumatic illustration. Bulkhead Assembly Installation See Figure for component illustration.. Remove the plug from the auxiliary port () in the bottom of the cabinet.. Install the bulkhead assembly (6) in the auxiliary port location as shown. The connector (7) and the lock nut (8) will be positioned inside the cabinet. The conduit seal (9), adaptor (0) and flow control valve () will be positioned outside of the cabinet.. Plug the 6mm tubing from the manifold assembly () into the male connector (7) of the bulkhead assembly (6).. For a dual pump system, repeat steps in auxiliary port location (). NOTE: See Figure for pneumatic illustration. 0 Nordson Corporation Part 60780-0

6 7 8 9 0 6 Figure Pump Cabinet Components (Two-Gun System Shown). Regulator. Auxiliary port. Electrode air wash manifold assembly 6. Bulkhead assembly. Electrode air wash manifold assembly 7. Male connector tee 8. Lock nut. 6mm tubing (re-use existing) 9. Conduit seal fitting 0. Adapter. Flow control valve. Auxiliary port Part 60780-0 0 Nordson Corporation

7 Wiring Harness Installation See Figure, item 8 for wiring illustration.. Connect the wiring harness (8) to the terminal block () and the pressure switch (6).. For dual pump system, connect the harness to the second pressure switch (7). Encore HD Controller Installation Controller Rail Mount See Figure 6.. Install the controller rail mount bracket to the arm on the product stand.. Install the controller to the universal mounting bracket.. Install the universal mounting bracket to the controller rail mount bracket. Figure 6 Controller Rail Mount Installation. Product stand arm. Controller rail mount bracket. Universal mounting bracket. Encore HD controller 0 Nordson Corporation Part 60780-0

8 Encore HD Powder Spray Gun Installation See Figure 7.. Connect the 6-mm atomizing air tubing to the quick-disconnect fitting () in the gun handle. Connect the other end to the Atomizing Air fitting on the power unit.. Connect the -mm clear electrode air wash tubing to the barbed fitting () in the gun handle. Connect the other end to the Gun Air fitting on the power unit.. Push the barbed hose adapter () into the end of the powder hose, then plug the adapter into the powder inlet tube () in the bottom of the spray gun handle.. Use the sections of black spiral wrap supplied with the system to bundle together the spray gun cable, air tubing, and powder hose. 6 Figure 7 Spray Gun Connections. Quick disconnect. Barbed fitting. Hose adapter. O-rings. Powder inlet tube 6. Gun cable Part 60780-0 0 Nordson Corporation

9 Encore HD Software Installation The USB-JTAG programmer and software package is required to upgrade the software for the Encore HD main control board and the flow module board. See Table for ordering information.. Download the latest USB-JTAG Programmer software from the Nordson Extranet. a. From your Internet browser, navigate to https://extranet.nordson.com/literature/default.aspx. b. Log in to the Nordson Extranet and click on Finishing, Coating & Curing Systems Marketing Collateral Resources & Support in the main panel. c. Click on Powder Software in the left panel. d. Click on the icon for Software Utilities, Tools and Instructions for Powder Products in the main panel. e. Choose the CAN Pro+ Software link to download the latest version of the software. f. Choose Run in the pop up window and follow instructions for downloading. NOTE: An application icon will be placed on the Windows desktop labeled USBJTAG. DO NOT START THIS APPLICATION UNTIL INSTRUCTED TO DO SO!. Plug the Nordson USB to JTAG Programmer module into a USB port on the PC. For programmer software versions.. and higher, the driver installation will now begin. You will see a number of pop-up messages in the system tray indicating that a new device has been detected and that drivers are being installed for this device. The final message will inform you that the device is ready for use.. To run the USB to JTAG application, double-click on the application icon on your desktop or on the file called USB-Jtag.exe. See Figure 8. 0 Nordson Corporation Part 60780-0

0 About Node Select Drop-down Software Select Button Selected Software File Name Progress Bar Click OK to Start Update Figure 8 USB to-jtag Control Box. Select the Node Select (top) drop-down menu and choose the desired node.. Click on the Software Select button (yellow folder) next to the selection box, then browse to the desired software file. The software files are located on your hard drive in the following path C:\USB-Jtag\SoftwareFiles. 6. Connect the USB JTAG programmer to the target node by lining up the red strip on the ribbon cable to pin of the connector on the PCB labeled JTAG. Plug the USB cord into the USB port on the host computer. 7. Apply power to the target node. 8. Click on the OK button to start the update process. 9. The progress bar fills to give an indication of the status of the download. A pop-up signals completion. 0. Select About and then Help for more detailed instructions. Table Network Adapter Ordering Information Item Part Description Quantity Note 60069 KIT, network adapter, CAN Pro+ NOTE: The package also contains bootloader software, which may be required for older systems. Bootloaders are special files that allow multiple nodes to be updated at the same time via the Nordson Over-the-Bus CAN programmer. Issued 07/0 Original copyright date 0. Prodigy, Encore, Nordson and the Nordson logo are registered trademarks of Nordson Corporation. Part 60780-0 0 Nordson Corporation