Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

Similar documents
Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Switchboards Instant Service

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

2.3. Molded Case Circuit Breakers. Contents

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Engine Generator Circuit Breakers

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

EOEM panelboard and switchboard (OPS) Program

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

SW Tog DP 30A 120/277V Autogrd B&S WH

CH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information

4750 Recp Duplex 15A 277V 2P3W H/L BK. Features amperage rating. Description RECP DUPLEX 15A 277V 2P3W H/L BK

Molded Case. Circuit Breakers. Molded Case Circuit Breakers Contents

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

N0N A 250V One-Time Class H Fuse

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

Cutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

1P 120/240V, 3600 RPM,

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

Cutler-Hammer. January 2001

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)

Type BR thermal magnetic trip curve results

Molded Case Circuit Breaker Selection Guide. Replacement Breakers for Eaton Panelboards

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

X1PB: Explosionproof Panelboards

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Circuit Breakers Naval Shipboard Use

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

20A-125V DPLX RCPT. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. Long Description

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Division 1 Explosionproof Panelboards

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Product Line Overview. The Most Logically Designed Contact Assembly

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

CIRCUIT BREAKER PANELBOARDS

Submittal Transmittal

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC/NYLON

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Mining service breakers with true rms sensing designed specifically for trailing cable applications

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

Installation Instructions for TMQV Circuit Breakers and Molded Case Switches

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

COMMENTS: PLEASE SEE A/E COMMENTS

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

561LVB 561LVB 4 Oct Box W/Bracket. Features. Dimensions and Weight. Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Vintage Westinghouse panelboards

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

TRBR20WBXSP 20A TR Comm WH Dup Rec. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight.

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

LFJ602003C 200A 600V Fus Block

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Multi-Pak Group Control

A302DN.40/.63A Thermal Current Motor Starter

Recp Duplex 20A 250V 2P3W STR Swire WH

Series L9 UL489 Miniature Circuit Breakers

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Molded Case Circuit Breakers

PANELBOARDS C1/C2 SECTION 6

Panelboards and Lighting Controls

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

Transcription:

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HFD3125 HFD3125 125A 3P CKT BRKR Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 125A Frame Size F-frame Poles 3 Trip Type Thermal magnetic Dimensions and Weight Height 6 Length IN Width 4.13 Descriptions Description Long Description Product Type Manufacturer Information Brand EATON CUTLER-HAMMER GTIN 00786679175903 Manufacturers Part Number HFD3125 series Series C UPC 786679175903 Taxonomies, Classifications, and Categories Category Description MOLDED CASE BREAKERS igcc 4927 unspsc code 39121616 Packaging Carton 1 Weight Per each 5 Uses, Certifications, and Standards Application standard HFD3125 Eaton Corp Series C, F-Frame Molded Case Circuit, 125A, Three-Pole, Thermal Magnetic Trip 5.0 (lbs/each) 3 Pole HFD3125 125A 3P CKT BRKR Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip Series C, F-Frame Molded Case Circuit Circuit Protection UL Listed

Supersedes February 2010 10 225 amperes Product description All of Eaton s s are HACR rated All F-Frame thermal-magnetic circuit breakers 10 50A are suitable for HID (high intensity discharge) use All s are suitable for reverse feed use Table 1. Frame Trip Ratings Frame Ampere Rating EDB, EDS, EDH, EDC 100 225 EHD 10 100 FDB 10 150 ED, HFD, FDC, HFDDC 15 225 FD 15 225 FDE, HFDE, FDCE 80, 160, 225 a The 80A FDE, HFDE, FDCE is adjustable from 15 80A. The 160A FDE, HFDE, FDCE is adjustable from 60 160A. The 225A FDE, HFDE, FDCE is adjustable from 100 225A.

Table 2. ULT 489 Interrupting Capacity Ratings Circuit Type EDB EDS ED EDH EDC d Number of Poles 2, 3 2, 3 2, 3 2, 3 2, 3 Interrupting Capacity (Symmetrical Amperes) Volts AC (50/60 Hz) Volts DC Trip Type a 240 277 480 600 125 250 bc T/M N.I.T. 22,000 42,000 T/M N.I.T. 65,000 100,000 200,000 EHD 1 2, 3 T/M N.I.T. 18,000 14,000 14,000 FDB 2, 3, 4 T/M N.I.T. 18,000 14,000 14,000 FD 1 T/M N.I.T. 35,000 2, 3, 4 65,000 HFD 1 T/M N.I.T. 65,000 2, 3, 4 100,000 35,000 65,000 18,000 25,000 22,000 FDC d 2, 3, 4 T/M N.I.T. 200,000 100,000 35,000 22,000 HFDDC e 3 T/M N.I.T. 50,000 f FDE HFDE FDCE d 3 3 3 Electronic N.I.T. Electronic N.I.T. Electronic N.I.T. 65,000 100,000 200,000 35,000 65,000 100,000 a N.I.T. is non-interchangeable trip unit. T/M is thermal-magnetic. For DC applications, magnetics are approximately 40% higher. b Two-pole circuit breaker, or two poles of three-pole circuit breaker. c Time constant is 3 milliseconds minimum at 10 ka and 8 milliseconds minimum at 22 ka. d Current limiting. e HFDDC is UL only and is not tested to other standards. f Interrupting rating is 42,000A at 600 Vdc with three-poles in series. 18,000 25,000 25,000 Table 3. Line and Load Terminals Maximum Amperes Terminal Body Material a Wire Type AWG Wire Range Metric Wire Range (mm 2 ) Catalog Number (Package of 3 Terminals) Standard Pressure Type Terminals 20 (EHD) 100 150 225 Steel Steel Aluminum Aluminum (1) #14 #10 (1) #14 1/0 (1) #4 4/0 (1) #4 4/0 2.5 4 2.5 50 25 95 25 95 3T20FB 3T100FB 3TA150FB 3TA225FD Optional Pressure Terminals 50 100 225 Aluminum Aluminum Aluminum (1) #14 #4 (1) #14 1/0 (1) #6 300 kcmil 2.5 16 2.5 50 16 150 3TA50FB 3TA100FD 3TA225FDK b a UL listed for use with copper or aluminum conductors as noted. b Use only on 175 225A. Includes terminal shield and increases height. Table 4. Approximate Shipping Weight in Lbs (kg) Number of Poles Circuit Type 1 2 3 4 ED, EDB, EDS, EDH, EDC 3 (1.4) 4.5 (2.0) EHD, FDB, FD, HFD, HFDDC, FDC 2 (0.9) 3 (1.4) 4.5 (2.0) 6 (2.7) FDE, HFDE, FDCE 4.2 (1.9) Table 5. Dimensions in Inches (mm) Number of Poles Dimensions 1 2 3 4 Height Width (34.8) 2.75 (69.9) 4.13 (104.8) 5.50 (139.7) Depth 2

Technical Data TD01203013E Dimensions in inches (mm) 4.12 (104.7) (34.8) 4.13 (104.8) 4.12 (104.7) Figure 1. Single-Pole F-Frame Figure 3. Three-Pole F-Frame 4.12 (104.7) 2.75 (69.9) 5.50 (139.7) 4.12 (104.7) Figure 2. Two-Pole F-Frame Figure 4. Four-Pole F-Frame NNote: For curves and additional technical information, please visit our Web site at www.eaton.com. 3

Front View 0.19 R (4.8 R) 1.41 (35.7) 2.72 (69.1) On Off 0.82 (20.8) 0.16 R (4.1 R) 0.45 (11.4) diameter 2 holes 0.11 (2.8) diameter x 0.31 (7.9) deep, 1 hole accept #6 (M3.5) thread cutting screws 1.03 (26.2) 4.00 (101.6) Side View Handle: 0.34 (8.7) wide x thick 0 taper, load end 7 taper, line end 2.35 (59.7) R 1.77 (44.8) (2.0) 0.22 (5.6) 0.09 R (2.4) R 0.19 (4.8) (12.7) wide conductor with 0.22 (5.6) diameter hole 0.63 0.27 (15.9) (6.8) 53 1.13 (28.6) 3.00 (76.2) Trough for attachment leads 0.09(2.3) R (Typ.) 4-PLC S. Push to trip E D B A 1.25 (31.8) 0.31 (8.0) 2.38 (60.3) 0.44 (11.1) 0.17 (4.4) 0.34 (8.7) 0.02 (.4) (12.7) 0.02 (.4) 1.00 (25.4) To top of clip (12.7) wide conductor with 0.22 (5.6) diameter hole (19.8) 2.22 (56.4) 2.94 (74.6) 3.19 (81.0) 3.50 (88.9) C 0.27 (6.8) 0.25 (6.4) 0.06 (1.6) Reproduced from drawings 1490D61 and 1490D65 Dimensions Handle status A B C D E force, lbs. On 3.07 (78.0) 2.92 (74.2) 3.96 (100.6) 3.40 (86.4) 3.33 (84.6) 8 Tripped 2.65 (67.3) 2.57 (65.3) 4.06 (103.1) 2.99 (75.9) 2.98 (75.7) 3 Off 2.08 (52.8) 2.14 (54.4) 4.12 (104.7) 2.42 (61.5) 2.56 (65.0) 9 Reset 1.98 (50.3) 2.05 (52.1) 4.11 (104.4) 2.30 (58.4) 2.48 (63.1) 10 Measured 0.125 (3.175) above Escutcheon. Applied by breaker to external mechanism. Dimensions in parentheses in millimeters Figure 5. Type FD Single-Pole Outline 4

Technical Data TD01203013E Front Cover Cutout Drilling Plans Front Connected Rear Connected 0.25 (6.4) R 2.31 (58.8) 2.91 (73.8) 2.88 (73.0) 3.16 (73.0) 1.91 (48.4) 0.19 (4.8) Diameter 1.19 (30.2) 0.59 (15.1) 5.06 Location of (12.7) diameter megger holes, if required 0.58 14.8) 0.164-32 (M4 x 0.7) tap, 2 holes 0.44 (11.1) diameter holes for 15 to 100A 0.56 (14.3) diameter holes for 125 to 150A Figure 6. Type FD Single-Pole Outline Drilling Plans 5

Front View Side View 0.19 R (4.8 R) 0.45 (11.4) diameter 4 holes 0.11 (2.8) diameter x.31 (7.9) deep, 2 holes accept #6 (M3.5) thread cutting screws 0.82 (20.8) 0.13 (3.2) x slots for attachment leads 1.77 (44.8) (2.0) (12.7) wide conductor with 0.22 (5.6) diameter hole [0.26 (6.6) diameter hole 175A] 0.63 0.27 (15.9) (6.8) 1.41 (35.7) 2.72 (69.1) 0.17 (4.4) On Off 1.33 (33.7) Push to trip 0.16 (4.0) R 1.72 (43.7) 0.34 (8.7) 1.03 (26.2) 4.00 (101.6) 0.13 (3.2) diameter x 0.48 (12.3) deep, 3 holes accept #8 (M4) thread cutting screws 2.35 (59.7) R E D B A 0.09 R (2.4) R 0.19 (4.8) 1.25 (31.8) 53 0.22 (5.6) 0.31 (8.0) 1.13 (28.6) 3.00 (76.2) 0.19 (12.7) 2.38 (4.8) (60.3) Trough for attachment leads 0.09 (2.3) R (Typ.) 4-PLC S. 0.02 (0.4) (12.7) 2.75 (69.9) 1.00 (25.4) 0.02 (0.4) 0.20 (5.0) diameter hole 0.33 (8.3) diameter c bore 1.94 (49.2) deep from top 0.34 (8.7) diameter c bore 0.66 (16.7) deep from bottom 2 mounting holes for 0.164-32 [#8] (M4 x 0.7) x 1.50 (38.1) mounting screws Handle: 0.34 (8.7) wide x thick 0 taper, load end 7 taper, line end To top of clip (12.7) wide conductor with 0.22 (5.6) diameter hole [0.25 (6.4) diameter hole 175A] (19.8) 2.22 (56.4) 2.94 (74.6) 3.19 (81.0) 3.50 (88.9) C 0.27 (6.8) 0.25 (6.4) 0.06 (1.6) Reproduced from drawings 1490D62 and 1490D66 Dimensions Handle status A B C D E force, lbs. On 3.07 (78.0) 2.92 (74.2) 3.96 (100.6) 3.40 (86.4) 3.33 (84.6) 12 Tripped 2.65 (67.3) 2.57 (65.3) 4.06 (103.1) 2.99 (75.9) 2.98 (75.7) 4 Off 2.08 (52.8) 2.14 (54.4) 4.12 (104.7) 2.42 (61.5) 2.56 (65.0) 15 Reset 1.98 (50.3) 2.05 (52.1) 4.11 (104.4) 2.30 (58.4) 2.48 (63.1) 20 Measured 0.13 (3.18) above Escutcheon. Applied by breaker to external mechanism. Dimensions in parentheses in millimeters Figure 7. Type FD Two-Pole Outline 6

Technical Data TD01203013E Front Cover Cutout Drilling Plans Front Connected Rear Connected 0.25 (6.4) R 2.31 (58.8) 2.91 (73.8) 2.88 (73.0) 3.16 (80.2) 1.91 (48.4) 1.19 (30.2) 0.59 (15.1) 0.58 (14.8) 5.06 (128.6) 0.19 (4.8) diameter Location of (12.7) diameter megger holes, if required 0.164-3 2 (M4 x 0.7) tap, 2 holes 0.44 (11.1) diameter holes for 15 to 100A 0.56 (14.3) diameter holes for 125 to 150A Figure 8. Type FD Two-Pole Outline Drilling Plans 7

Front View 0.20 (5.0) diameter hole 0.33 (8.3) diameter c'bore 1.94 (49.2) deep from top. 0.34 (8.7) diameter c'bore 0.66 (16.7) deep from bottom. 4 munting holes for.164-32 (No. 8) x 1.50 (M4 x 0.7 x 38.1) mounting screws. 0.19 (4.8)R 0.45 (11.4) diameter 6 holes 0.11 (2.8) dia. x 0.31 (7.9) deep, 2 holes accept #6 (M3.5) thread cutting screws Side View 0.13 (3.2) x.75 slots for attachment leads 1.77 (44.8) (2.0) 0.63 0.27 (15.9) (6.8) (12.7) wide conductor with 0.22 (5.6) diameter hole [0.26 (6.6) diameter hole 175A] 1.41 (35.7) 0.09 (2.3) R (Typ.) 4-PLC S. 1.72 (43.7) 0.17 (4.4) 0.02 (0.4) 0.13 (3.2) x 0.48 (12.3) deep 6 holes accept #8 (M4) thread cutting screws 2.06 (52.4) (12.7) On Off 1.33 (33.7) 1.33 Push to trip (33.7) 4.13 (104.8) 0.16 R (4.0) R 1.00 (25.4) 0.82 (20.8) 0.34 (8.7) 0.02 (0.4) 1.03 (26.2) 4.00 (101.6) 2.35 (59.7) R E D B A Handle: 0.34 (8.7) wide x thick 0 taper, load end 7 taper, line end To top of clip (12.7) wide conductor with 0.22 (5.6) diameter hole [0.25 (6.4) diameter hole 175A] (19.8) 2.22 (56.4) 2.94 (74.6) 3.19 (81.0) 3.50 (88.9) C 0.09 R (2.4) R 0.19 (4.8) 1.25 (31.8) 53 0.22 (5.6) 0.31 0.19 (8.0) (4.8) 2.38 (60.3) 0.27 (6.8) 0.25 (6.4) 0.06 (1.6) 1.13 (28.6) 3.00 (76.2) (12.7) Trough for attachment leads Reproduced from drawings 1490D63 and 1490D67 Dimensions Handle status A B C D E force, lbs. On 3.07 (78.0) 2.92 (74.2) 3.96 (100.6) 3.40 (86.4) 3.33 (84.6) 14 Tripped 2.65 (67.3) 2.57 (65.3) 4.06 (103.1) 2.99 (75.9) 2.98 (75.7) 4 Off 2.08 (52.8) 2.14 (54.4) 4.12 (104.7) 2.42 (61.5) 2.56 (65.0) 16 Reset 1.98 (50.3) 2.05 (52.1) 4.11 (104.4) 2.30 (58.4) 2.48 (63.1) 21 Measured 0.13 (3.18) above Escutcheon. Applied by breaker to external mechanism. Dimensions in parentheses in millimeters Figure 9. Type FD Three-Pole Outline 8

Technical Data TD01203013E Front Cover Cutout Drilling Plans Front Connected Rear Connected 0.25 2.31 (58.8) 2.91 (73.8) 2.88 (73.0) 3.16 (80.2) 1.91 (48.4) 1.19 (30.2) 0.59 (15.1) 0.58 (14.8) 5.06 (128.6) 0.19 (4.8) Diameter Location of (12.7) diameter megger holes, if required 0.164-32 (M4 x 0.7) tap, 4 holes 2.75 (69.9) 0.44 (11.1) diameter holes for 15 to 100A 0.56 (14.3) diameter holes for 125 to 150A Optional Ring Terminal Dimensions 0.73 (18.5) 0.27 (6.8) Dia. 0.22 (<=160A) (5.6) 0.25 (>160A) (6.4) Figure 10. Type FD Three-Pole Outline Drilling Plans 9

Front View Side View 1.41 (35.7) 1.72 (43.7) 2.72 (69.1) 0.09 (2.3)R (Typ.) 4-PLCs 0.19 R (4.8) R On Off 1.33 1.33 (33.7) Push to trip (33.7) 0.16 (4.0) R 0.125 (3.18) x 0 (19.05) slots 0.45 (11.4) diameter for attachment leads 8 holes 0.11 (2.8) diameter x 0.31 (7.9) deep, 4 holes accept #6 (M3.5) thread cutting screws 0.82 (20.8) 1.03 (26.2) 0.13 (.32) diameter x 0.49 (12.3) deep, 6 holes accept #8 (M4) thread cutting screws 4.00 (101.6) 0.34 (8.7) 2.35 (59.7) R E D B A 1.77 (44.8) (2.0) 0.09 R (2.4) R 0.19 (4.8) 1.25 (31.8) (12.7) wide conductor with 0.22 (5.6) diameter hole [0.26 (6.6) diameter hole 175A] 0.63 0.27 (15.9) (6.8) 53 0.22 (5.6) 1.13 (28.6) 3.00 (76.2) 0.31 0.19 (12.7) (8.0) (4.8) 2.38 (60.3) Trough for attachment leads 0.17 0.02 (4.4) (0.4) 2.06 (52.4) (12.7) 5.50 (139.7) 1.00 (25.4) (17.4) 0.02 (0.4) 0.20 (5.0) dia hole 0.33 (8.3) dia c bore 1.94 (49.2) deep from top 0.34 (8.7) dia c bore 0.66 (16.7) deep from bottom 2 mounting holes for 0.164-32 [#8] (M4 x 0.7) x 1.50 (38.1) mounting screws Handle: 0.34 (8.7) wide x thick 0 taper, load end 7 taper, line end To top of clip 0 (12.70) wide conductor with 0.219 (5.56) diameter hole [0.250 (6.35) diameter hole 175A] (19.8) 2.22 (56.4) 2.94 (74.6) 3.19 (81.0) 3.50 (88.9) C 0.27 (6.8) 0.25 (6.4) 0.06 (1.6) Reproduced from drawings 1490D64 and 1490D68 Dimensions Handle status A B C D E force, lbs. On 3.07 (78.0) 2.92 (74.2) 3.96 (100.6) 3.40 (86.4) 3.33 (84.6) 14 Tripped 2.65 (67.3) 2.57 (65.3) 4.06 (103.1) 2.99 (75.9) 2.98 (75.7) 4 Off 2.08 (52.8) 2.14 (54.4) 4.12 (104.7) 2.42 (61.5) 2.56 (65.0) 16 Reset 1.98 (50.3) 2.05 (52.1) 4.11 (104.4) 2.30 (58.4) 2.48 (63.1) 21 Measured 0.13 (3.18) above Escutcheon. Applied by breaker to external mechanism. Dimensions in parentheses in millimeters Figure 11. Type FD Four-Pole Outline 10

Technical Data TD01203013E Front Cover Cutout Drilling Plans Front Connected Rear Connected 0.25 (6.4) R 2.31 (58.8) 0.59 1.91 (48.4) (15.1) 1.19 (30.2) 2.91 (73.8) 0.19 (4.8) diameter 2.88 (73.0) 3.16 (80.2) 5.06 (128.6) 0.58 (14.8) (35.0) (35.0) Location of (12.7) diameter megger holes, if required (35.0) 2.75 (69.9) 0.164-32 (M4 x 0.7) tap, 6 holes 2.75 (69.9) 4.13 (104.8) 0.44 (11.1) diameter holes for 15 to 100A 0.56 (14.3) diameter holes for 125 to 150A Figure 12. Type FD Four-Pole Outline Drilling Plans 11

Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com 2011 Eaton Corporation All Rights Reserved Printed in USA Publication No. TD01203013E / Z10989 March 2011 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.