Application of AC Dahlander Three-Phase Induction Motor AEL-ACDHA

Similar documents
Application of AC Three-Phase Induction Motor of Squirrel Cage AEL-ACINA

Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA

DC Brushless Motor Application AEL-DCBRA

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

Transparent and Functional Motors Application AEL-FTM

Motor-Generator and Transformer Construction Application AEL-MGTC

MGI. Gyroscope PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

Wind Energy Unit EEE. Engineering and Technical Teaching Equipment PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

Biodiesel Process Unit EBDB

Basic Unit of Mechanical Drive Systems MDSU. Engineering and Technical Teaching Equipment INTRODUCTION GENERAL DESCRIPTION

Assembly and Maintenance of Pumps AMP

Energy Power Plants Trainer AEL-EPP

AEL-4. Advanced Electrical Laboratories (AEL-LABS): Electromechanical Constructions Lab. Engineering and Technical Teaching Equipment

Electrical Machines Lab

Photovoltaic Solar Energy Modular Trainers

Photovoltaic Solar Energy Modular Trainers

TECNEL. Computer Controlled Teaching Unit for the Study of Power Electronics. (Converters:DC/AC+AC/DC+DC/DC+AC/AC)

Final User Smart Grid Trainer AEL-FUSG

Screenshot of the computer data acquisition and calculations software INTRODUCTION

Hydraulic and Electro-Hydraulic Application AE-HD

Power Systems and Smart Grid Technology Lab

Photovoltaic Solar Energy Unit EESFB

Integrated Laboratory for Electrical Machines LIMEL

Fluid Friction in Pipes, with Hydraulics Bench (FME00) AFT

AEL-3. ELECTRICAL MACHINES LAB AEL-2. HOME AUTOMATION SYSTEMS LAB

Pneumatic and Electro-Pneumatic Application AE-NS INTRODUCTION

BAIJI OIL TRAINING INSTITUTE ISO-9001:2008 DATE :1/4/2014 LABORATORY FOR THE ELECTRICAL SYSTEMS AND CONTROL OF OIL DRILLING RIGS $

WORK BENCHES FOR ELECTRIC INSTALLATIONS. index

Brake Test On Three Phase Induction Motor Lab Manual

ELECTRIC MACHINES EUROLAB 0.3 kw

ES09 ELECTRICAL MACHINES TECHNICAL SPECIFICATIONS

SWITCHGEAR. 4G cam switches

Electrical Power Systems 2014/15

Starting of Induction Motors

ELECTRIC MACHINES EUROLAB 0.3 kw

Installation Manual for DC Injection Brake Units

8036-A0 Motor Drives Training System (Stand-Alone)

Load Test On 3 Phase Slip Ring Induction Motor Lab Manual

ELECTRIC MACHINES UNILAB 1 kw

ICG Switchgear Price List 2009

2 kw Electromechanical Training Systems

The Wound-Rotor Induction Motor Part I

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

EMMS3 ELECTRICAL MACHINES MODULAR SYSTEM 300W

Industrial Wiring Training Systems

0.2 kw Electric Power Transmission Training System

Industrial Controls Training Systems

Open Chassis Star-Delta Starter User Guide

Motor Drives Training System (Stand-Alone, 120 V Version) (8036-C0)

Model ED 720 Drying and heating chambers Classic.Line with natural convection

RENEWABLE ENERGY TRAINER

Model ED 400 Drying and heating chambers Classic.Line with natural convection

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

SPECIFICATIONS NB SKILLS TRADE 19 AUTOMATION AND CONTROL

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

Model ED 400 Drying and heating chambers Classic.Line with natural convection

CI-TI Contactors and motor starters Types CI 61 - CI 98

Training & Didactic Systems. Fundamentals of Electrical Engineering

Electrical Power Electric power electrical electric power Electric power electric electric

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU. INDIA CAPITAL EQUIPMENT/ MATERIALS MANAGEMENT

Overview. Contents. Overview

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

Junction boxes for control, monitoring and control panel Ex tb

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

Power Conversion System The Best Technology for your photovoltaic and storage system

SQA Advanced Unit specification: general information

Syllabus for the Trade of Electrician Duration : Six Month Second Semester Semester Code: ELE: SEM II

4.7. Definite Purpose Contactors and Starters. Contents. Reversing/Assignment Contactor. Direct Current Contactors

Motor Starting Solutions Open Type Version, in Kit Form

Installation & Operation Manual

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

Variable-Frequency Drive Training System

Asynchronous generators

Electricity Course. Part B Course Outline

HIGH POWER SOLENOID DRIVER 1

Electrical Power & Machines Range

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Power Systems Trainer

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

Technical Data Sheets

SD Series Non-Fused Load Switches

RVS-AX Instruction Manual

UNC-Charlotte's Power Engineering Teaching lab

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

SDS Enclosed Star-Delta Starter User Guide

Standby Amper VOLTAGE

Standby Amper VOLTAGE

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

MAIN COMMON FUNCTIONS

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Fachpraktikum Elektrische Maschinen. Experiments with a 400/ 690 V Squirrel Cage Induction Machine

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

SOLSTART Instruction Manual

Three-Phase Motors and Drives

TECHNICAL SPECIFICATION

INDIAN MARITIME UNIVERSITY KOLKATA CAMPUS

RVS-DN Digital Reduced Voltage Motor Starter

CI-TI Contactors and Motor Starters Type CI 6-50

A Electric Power / Controls SMART GRID TECHNOLOGIES 0.2 kw

Technical Data Sheets

Transcription:

Engineering and Technical Teaching Equipment Application of AC Dahlander Three-Phase Induction Motor AEL-ACDHA INTRODUCTION The electric motors are devices capable of transforming electrical energy into mechanical energy. The squirrel cage and dahlander motors are very used in industrial installations due to its great robustness, reliability and low cost. The starting current consumed by these motors is very high, being harmful to the machine and the protections. The soft starters aim at reducing these currents close to the nominal values. For this purpose it is very important to know several operations carried out with these electrical machines. ISO 9001: Quality Management (for Design, Manufacturing, Commercialization and After-sales service) European Union Certificate (total safety) 1 Certificates ISO 14001 and ECO- Management and Audit Scheme (environmental management) Certificate and Worlddidac Member

GENERAL DESCRIPTION The Application of AC Dahlander Three-Phase Induction Motor, AEL-ACDHA, is designed for the study of the main operations performed in the industrial field with dahlander electrical motors. The student will learn the most important operations of these electrical machines faithfully by using commutators, timers and contactors. The AEL-ACDHA includes the following modules: N-ALI01. Industrial Power Supply. N-ARR12. Direct Starter. N-ARR01. Manual Star-Delta Starter. N-ARR13. Direct Starter with Inversion. N-ARR05. Manual Star-Delta Starter with Inversion. N-ARR07. Manual Dahlander Commutator, 2 Speeds. N-ARR11. Poles Commutation with Inversion. N-PUL48. 3 Double Chamber Push-Buttons. N-LAM02. Auxiliary Lamps. N-CON01. 3-pole Contactor (24 VAC). (4 units) N-REL30. Synchronization Relay. (3 units) N-ALI03. AC Auxiliary Power Supply. N-TRANS03. Three-Phase Autotransformer 400/230 VAC, 1 kva, Module. EMT9. Dahlander three-phase motor (2 speeds). FLYW. Flywheel. EMT7. Asynchronous three-phase motor of squirrel cage. Additional and recommended measurement instrumentation modules: - Digital Instrumentation: N-EALD. Network Analyzer Unit with Computer Data Acquisition. - Analog Instrumentation: N-MED10. AC Ammeter (0-5 A). N-MED22. AC Voltmeter (0-400 VAC). N-MED33. 3-Phase Balanced Wattmeter 440 V. N-MED31. 3-Phase Phasemeter 400V. N-MED39. 3-Phase Balanced Varmeter 440 V. If the Option A (modules mounted on rack) is chosen, the rack/s required will depend on the optional modules requested by the customer. Expansion learning software: In addition, Edibon provides expansion learning software (AEL-ACDHA/ICAI) to reinforce knowledge about this field. This software is formed by: ECM-SOF. EDIBON Classroom Manager (Instructor Software). ESL-SOF. EDIBON Student Labsoft (Student Software). The application AEL-ACDHA can be mounted on rack (option A) or on rail (option B): Option A: This application needs the following racks: N-RACK-A. (2 units) Optionally the AEL-WBR. Electrical Workbench (Rack) can be supplied to place the rack/s. Option B: This application can be mounted on rail. Optionally the AEL-WBC. Electrical Workbench (Rail) can be supplied to mount the modules. 2

SPECIFICATIONS The application includes the following modules: N-ALI01. Industrial Power Supply. Supply voltage: 400 VAC, 3 PH+N+G. ON-OFF removable key. Output voltage connections: Three-Phase + Neutral: 400 VAC. Single-Phase: 230 VAC. Three-Phase supply hose with IP44 3PN+E 32A 400 V connecting plug. Differential magnetothermal, 4 poles, 25 A, 300 ma AC 6 KA. N-ALI01 N-ARR12. Direct Starter Module. Two positions commutator (ON-OFF): 1: Closed circuit. N-ARR01. Manual Star-Delta starter. Star-Delta three positions commutator: Y: Star connection. Δ: Delta connection. N-ARR13. Direct Starter with Inversion Module. Three positions commutator: 1: Direct connection. 2: Reverse connection. N-ARR12 N-ARR01 N-ARR05. Manual Star-Delta Starter with Inversion. Star-Delta three positions commutator: Y: Star connection. Δ: Delta connection. N-ARR13 N-ARR07. Manual Dahlander Commutator Module. Three positions commutator: 1: Low speed. 2: High speed. N-ARR05 N-ARR011. Poles Commutation with Inversion. 2x commutators: Direction selector: 1: Anticlockwise direction. 2: Clockwise direction.. Speed selector: 1: Speed 1. 2: Speed 2. 3 N-ARR07 N-ARR11

Specifications N-PUL48. 3 Double Chamber Push-Buttons. Two independent chambers. Nominal voltage: 24 VAC. Three double chamber push-buttons (green and red). Contacts: Three Normally Open Contacts (NO) for green switch. Three Normally Close Contacts (NC) for red switch. Ground terminal. N-PUL48 N-LAM02. Auxiliary Lamps. Nominal voltage: 24 VAC. Three lamps (red, yellow and green). Ground terminal. N-CON01. 3-poles Contactor (24 VAC). (4 units) Nominal voltage for power contacts: 400 VAC. Nominal voltage for control contacts: 24 VAC. Nominal voltage for the control coil: 24 VAC. Contacts: One three-phase Normally Open Contact (NO) for power circuit. Three Normally Open Contacts (NO) for control circuit. Two Normally Close Contacts (NC) for control circuit. Ground terminal. N-LAM02 N-CON01 N-REL30. Synchronization Relay Module. (3 units). Nominal voltage for power contacts: 400 VAC. Nominal voltage for control contacts: 24 VAC. Nominal voltage for the control coil: 24 VAC. Contacts: One three-phase Normally Open Contact (NO) for power circuit. Three auxiliary contacts: One instantaneous Normally Open Contact (NO). One time Normally Open Contact (NO). One time Normally Close Contact (NC). Ground terminal. N-REL30 N-ALI03. AC Auxiliary Power Supply. Supply voltage (Single-Phase): 230 VAC PH+N+G. Output voltage: Single-Phase 24 VAC/12 VAC. 24 VDC. 0-24 VDC through potentiometer. N-ALI03 N-TRANS03. Three-Phase Autotransformer 400/230 VAC, 1 kva, Module. Three-phase autotransformer. Nominal supply voltage: 400 VAC (3PH). Nominal output voltage: 3 x 230 VAC (3PH+N). Nominal power: 1 kva. Transformer connection: YY0. Start/stop commutator for instantaneous connection/disconnection of the grid transformer. Fuses: 3 x 5 A. 4 N-TRANS03

EMT9. Dahlander three-phase motor (2 speeds). Specifications Nominal power: 370 W. Nominal voltage: 3x 400 VAC. Frequency: 50/60 Hz. Number of poles: 4. EMT9 RPM: 1400/2800 r.p.m. Nominal current: 1,2 / 1,55 A. FLYW. Flywheel. Weight: 2 kg Maximum recommended speed: 4000 r.p.m. Moment of inertia: 0,0025 kgm ² FLYW EMT7. Asynchronous Three-Phase Motor of Squirrel Cage. Nominal power: 370 W. Nominal voltage: 3 x 230/400 VAC Δ/Y. Frequency: 50/60 Hz. Number of poles: 2. EMT7 RPM: 2730 r.p.m. Nominal current: 1,67/ 0,97 A. Additional and recommended measurement instrumentation modules: N-EALD. Network Analyzer Unit with Computer Data Acquisition. ON-OFF switch. Supply voltage: 400 VAC. Input terminals: Input connection with the measurement point. Output terminals: Output connection with the measurement point. N-EALD Digital outputs: Three digital outputs are used for pulses or alarms, or for combining both. RS-485 Communication port. Fuses: 3 x 10 A. Network Analyzer Display. It shows: Active, reactive and apparent power. Active, reactive and apparent energies. Lines and phase currents. Line and phase voltages. Frequencies. Power Factor. 5

N-MED10. AC Ammeter (0-5 A). Specifications Measurement range: 0-5 A. Terminals: Measurement Terminals. Ground Terminal. N-MED10 N-MED22. AC Voltmeter (0-400 VAC). Measurement range: 0-400 VAC. Terminals: Measurement Terminals. Ground Terminal. N-MED22 N-MED33. 3-Phase Wattmeter 440 V. Nominal voltage 440 VAC. Terminals: Measurement Terminals. Ground Terminal. N-MED33 N-MED31. 3-Phase Phasemeter 400 V. 3 phasemeter. 400 VAC. CAP 0.5-1-0.5 IND. Accuracy 1.5 % of 90º. N-MED31 50 or 60 Hz. N-MED39. 3-Phase Balanced Varmeter 440 V. 3 phase balanced varmeter. 440 VAC. Range: 0-300 Var. Scale 90º. N-MED39 Accuracy 1.5%. 50 or 60 Hz. All necessary cables to realize the practical exercises are included. Cables and Accessories, for normal operation. Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals. 6

EXERCISES AND PRACTICAL POSSIBILITIES 1.- Checking the Industrial Main Power Supply (N-ALI01). 2.- Checking the AC Auxiliary Main Power Supply (N-ALI03). 3.- Checking the lamps. 4.- Study of the control elements of alternating-current motors. 5.- Manual star-delta circuit of three-phase induction motor. 6.- Manual star and reverse operation of Dahlander motor. 7.- Manual star-delta with inversion circuit of three-phase induction motor. REQUIRED SERVICES - Electrical supply: three-phase, 380V/50 Hz or 208V/60 Hz, 20 Kw. 8.- Manual speed variation of a Dahlander motor. 9.- Manual speed variation of a Dahlander motor with inversion. 10.- Automatic star-delta starter of three-phase induction motor. 11.- Automatic star-delta reversing circuit of three-phase induction motor. 12.- Automatic velocity variation of a Dahlander motor. 13.- Use of the flywheel. DIMENSIONS AND WEIGHTS AEL-ACDHA: -Dimensions: 640 x 320 x 920 mm approx. (25.19 x 12.59 x 36.26 inches approx.) -Weight: 60 Kg approx. (132 pounds approx.) 7

Optional AEL-ACDHA/ICAI. Interactive Computer Aided Instruction Software System: With no physical connection between unit and computer (PC), this complete software package consists of an Instructor Software (EDIBON Classroom Manager -ECM-SOF) totally integrated with the Student Software (EDIBON Student Labsoft -ESL- SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. Instructor Software - ECM-SOF. EDIBON Classroom Manager (Instructor Software). ECM-SOF is the application that allows the Instructor to register students, manage and assign tasks for workgroups, create own content to carry out Practical Exercises, choose one of the evaluation methods to check the Student knowledge and monitor the progression related to the planned tasks for individual students, workgroups, units, etc... so the teacher can know in real time the level of understanding of any student in the classroom. Innovative features: User Data Base Management. Administration and assignment of Workgroup, Task and Training sessions. Creation and Integration of Practical Exercises and Multimedia Resources. Custom Design of Evaluation Methods. Creation and assignment of Formulas & Equations. ECM-SOF. EDIBON Classroom Manager (Instructor Software) Application Main Screen Equation System Solver Engine. Updatable Contents. Report generation, User Progression Monitoring and Statistics. ECAL. EDIBON Calculations Program Package - Formula Editor Screen ETTE. EDIBON Training Test & Exam Program Package - Main Screen with Numeric Result Question ERS. EDIBON Results & Statistics Program Package - Student Scores Histogram 8

Innovative features: Student Log-In & Self-Registration. Existing Tasks checking & Monitoring. Optional Student Software - ESL-SOF. EDIBON Student Labsoft (Student Software). ESL-SOF is the application addressed to the Students that helps them to understand theoretical concepts by means of practical exercises and to prove their knowledge and progression by performing tests and calculations in addition to Multimedia Resources. Default planned tasks and an Open workgroup are provided by EDIBON to allow the students start working from the first session. Reports and statistics are available to know their progression at any time, as well as explanations for every exercise to reinforce the theoretically acquired technical knowledge. Default contents & scheduled tasks available to be used from the first session. Practical Exercises accomplishment by following the Manual provided by EDIBON. Evaluation Methods to prove your knowledge and progression. Test self-correction. ESL-SOF. EDIBON Student LabSoft (Student Software) Application Main Screen Calculations computing and plotting. Equation System Solver Engine. User Monitoring Learning & Printable Reports. Multimedia-Supported auxiliary resources. For more information see ICAI catalogue. Click on the following link: /en/files/expansion/icai/catalog EPE. EDIBON Practical Exercise Program Package Main Screen ECAL. EDIBON Calculations Program Package Main Screen ERS. EDIBON Results & Statistics Program Package - Question Explanation * Specifications subject to change without previous notice, due to the convenience of improvement of the product. REPRESENTATIVE: C/ Del Agua, 14. Polígono Industrial San José de Valderas. 28918 LEGANÉS. (Madrid). ESPAÑA - SPAIN. Tel: 34-91-6199363 Fax: 34-91-6198647 E-mail: edibon@edibon.com Web: Edition: ED01/17 Date: September/2017 9