ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016

Similar documents
ASYNCRONOUS MOTORS OPERATING INSTRUCTIONS 2018

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

SERVO MOTORS BRUSHLESS SERVO MOTORS ATEX ZONE 2-22 OPERATING INSTRUCTIONS 2016

VEM motors Thurm GmbH

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

MOUNTING & MAINTENANCE INSTRUCTIONS FOR

Mounting & Maintenance Instructions OMT1 & OMT2 Motors

INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For THREE-PHASE INDUCTION MOTORS TYPE HJN / HJA

BAH series Use and Maintenance Manual

Installation and Operating Instructions Electric Vibrators HV/VFL Series

INTRODUCTION GENERAL GUIDELINES ATTACHING THE DRIVE PARTS

THREE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATING MANUAL. (Original Instructions)

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

champion series motors

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03

Technical Manual Electrical Power Supply System T4002

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS. Frames 143T - 449T

VALIADIS S.A. HELLENIC MOTORS

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

: B3; B5; B14; B34; B35; V1

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

AC Induction Motors. Installation and operating instructions

Installation and Operational Instructions for ROBA -D Couplings Type 91_. _

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design

SERIES G3DB/AG3DB ELEVATOR

[ T] THREE-PHASE MOTORS «[32] [33] Three-Phase Motors - Technical Catalogue 1018/10

Operating Instructions

Design specifications

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

CE Marking. Number of poles. Core Length. Frame size

1LG0 Low-voltage Motors

Installation, operating and maintenance instructions

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

LV Capacitor CLMD03 Power Module Instruction manual

T8 Torque Sensor Operation Manual

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

Appendix: Safety and application notes for... 15

Brake Motors Aluminium Frame Improved Efficiency EFF2

SINGLE PHASE TEFC CAGE MOTORS

GMP-Type. Key Features: Integrated Motor-Pump Units

Operating Instructions

INTRODUCTION WARNING SIGNS AND THEIR MEANINGS

BoWex FLE-PA. BoWex FLE-PAC. KTR-N Sheet: Edition: EN 1 of BoWex FLE-PA / FLE-PAC Operating/Assembly instructions

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

ELECTRICAL MACHINES, DRIVE SYSTEMS AND SYSTEM ENGINEERING. Operating Manual. Three-Phase-Low-Voltage-Squirrel-Cage Machines

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

Monocellular centrifugal electro-pumps

Dry installed pump type LANDY BTP.

Lenze. Drives with worm gearboxes 52.

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

THREE PHASE INDUCTION MOTORS

Actuators for air and gas dampers

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

COMPABLOC. Cb Cb Cb 1504 Installation and maintenance. These instructions should be given to the end user GN

From 16 June 2011, motors placed for the first-time on the market shall have a minimum efficiency class of IE2.

Assembly and Maintenance Manual Type ASNU

Chapter 5 FOUNDATION. 2010, The McGraw-Hill Companies, Inc. 2010, The McGraw-Hill Companies, Inc.

D58 Series Brake Instructions

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

Installation and Operating Instructions for ROBA -ES couplings Type 940. _. _ Sizes 14-48

Appendix: Safety and application notes for 19

CENTAX-SEC Series B Assembly and operating instructions CX BFS1-LE/SE-**-B M EN Rev. 1

Electromagnetic single disc clutches E210 and E220

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

General Purpose Cast Iron Motors

Installation and Operational Instructions for EAS -Compact overload clutch, Type 49_. 4._ Sizes 4 and 5

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

Operating Instruction

Operating manual Separator

General operation manual. induction cage-motors

INTER PLANT STANDARD STEEL INDUSTRY. SPECIFICATION FOR GENERAL PURPOSE SQUIRREL CAGE INDUCTION MOTORS (Fifth Revision) BASED ON IS 325:1996

SECTION MOTOR REQUIREMENTS for HVAC

MODVAR Low voltage reactive power compensation modules Installation manual

Open Chassis Star-Delta Starter User Guide

HIB Enclosed Inverter User Guide

Compact System NRGS 11-2 NRGS Original Installation Instructions English

HT SERIES SMOKE VENTING EQUIPMENT

MVSI-TS. Split covers. Technical features

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

Medium and high pressure pumps

Below, you can see the warning symbols used throughout the manual and their meaning.

Axial-radial cylindrical roller bearings

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Assembly and Maintenance Manual Type AS

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Three-phase asynchronous motors

Transcription:

ASYNCHRONOUS INSTRUCCIONES DE SERVICIO MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS OPERATING INSTRUCTIONS 2016 3006/16 en Ed.02.2016

Read these Operating Instructions before you transport, install, commission, maintain or repair industrial motors or generators. These symbols will draw your attention to the safety measures and additional instructions given in these Operating Instructions. Special instructions regarding safety and warranty: Danger: For reasons of protection of persons and objects, all the safety measures and additional instructions given in these Operating Instructions must be strictly complied with. Low-voltage machines have dangerous rotating and conductive parts, as well as possibly hot surfaces. All transport, installation, commissioning, maintenance and repair works have to be carried out exclusively by qualified personnel and checked by responsible experts (observe VDE 0105; IEC 364). Inappropriate use may cause major damage to persons and objects. Should additional data be required, you should immediately consult the manufacturer or an authorized service workshop. All work on electrical connections to the motors and generators should only be carried out by qualified personnel. GENERAL INFORMATION SCOPE These instructions refer to surface-ventilated three-phase and AC low-voltage cage induction motors and generators, IP 54 and IP 55 to DIN VDE 0530, part 5, EN 60034 and IEC 34-5. Higher degrees of protection are indicated on the rating plate. These low-voltage machines are intended for industrial installations. They comply with the harmonized standards DIN VDE 0530/EN 60034. Observe any possible special prescriptions for their use. Aircooled low-voltage machines are designed for operation at altitudes 1000 m above sea level and at ambient temperatures between - 20 C and +40 C. Exceptions are stated on the rating plate. Observe especially different indications on the rating plate. The conditions at the place of use must coincide with all the data of the rating plate. The low-voltage machines are components of a machine according to the Directive Machines 2006/42/CE. The commissioning of this machine is forbidden until conformity of the final product with this directive is proved (observe EN 60204-1). TRANSPORT Should any damage be observed after delivery of the low voltage machine at its destination, these should be notified immediately to the transport company; avoid commissioning. LIFTING EYES Lift motors only on lifting eyes provided. Do not add any load to the motor. Lifting eyes are designed for the motor mass only. Should it be necessary, use appropriate cable guides. ROTOR LOCKING DEVICE Motors with roller bearings are protected against bearing damage during transport by means of a locking device which has to be removed before putting the motor into operation. Close the fixing hole by means of the plug supplied. The locking device must also be used for any further transport of the motor. VENTILATION The distance between air intake of the motor and walls or other machinery must be at least ¼ of the diameter of the air intake opening. Cooling air flows from the non-drive end towards the drive end. Air leaving the motor must not be drawn in again by the fan. Keep air inlets and outlets clean. For vertical shaft-up designs, suitable protection must be provided at the mounting end so that no foreign matter can enter the ventilation hole. Such protection must, however, not affect the cooling and air leaving the motor/generator - or adjacent groups - must not be drawn in again. CONDENSATION DRAIN HOLES Even after installation the condensation drain holes must be at the lowest point of the motor. They must be kept clean. Plug drain hole after each drainage. INSTALLATION AND COMMISSIONING MECHANICAL TRANSMISSION ELEMENTS Use elastic couplings only; rigid couplings require a special bearing design. When using transmission elements which provoke radial or axial shaft loads during operation (e.g. pulleys, gearwheels, etc.) take care that the permissible loads are not exceeded. Relevant data are given in the respective technical catalogue. Rotors are at present dynamically balanced with half key. (As per DIN ISO 8821). «H» or «blank» means balanced with half key «F» means balanced with full key «N» means no key When the motor is balanced with a half key (H), the coupling has also to be balanced with half key; machine the overhanging visible part of the key. Remove anti-corrosion paint by means of a suitable solvent and grease the shaft extension. Use only suitable tools to mount or pull off pulleys or couplings, see Fig. 1-3, (heat to 80-100 C) and cover with a protection against accidental contact. Avoid inadmissible tension of the belts (technical catalogue). By no means the bearings may be subjected to any pressure or shock. Remove fancover Fig. 1 Mounted without female thread Fig. 2 Mounted with female thread Fig. 3 Pulling off OPERATING INSTRUCTIONS FOR THREE-PHASE, SINGLE-PHASE AND BRAKE MOTORS 3006/16 en Ed. 02.2016 1

SUBSTRUCTURE Make sure that the feet or flanges are safely fixed and rest positively on their entire surface. Check also the exact alignment with direct coupling. All motor feet must rest positively on their entire surface to avoid distortion of the motor frame. Avoid resonance of the base with the turning frequency and double mains frequency. Turn the rotor by hand. Check the direction of rotation with the machine uncoupled (see Vibrations during operation ). ALIGNMENT When the motor is connected to the driven machine via a coupling, the shafts must be aligned radially and axially to each other. The dial gauges must be firmly secured. Measurements have to be taken at four points, displaced by 90, while both coupling halves are turned simultaneously. ANGULAR ALIGNMENT (FIG. 4) Deviations are to be equalized by means of shims placed under the motor feet. Permanent inaccuracies must not exceed 0.03 mm, referred to a diameter of 200 mm. PARALLEL ALIGNMENT (FIG. 5) Deviations are to be equalized by placing shims under the motor. The remaining inaccuracies must not exceed 0.03 mm. The adjustment of the axial clearance between the coupling halves (dimension «E») is to be effected in accordance with the coupling manufacturers specification. Re-check alignment with the machine at operating temperature. COMBINATION OF ANGULAR AND PARALLEL ALIGNMENT (FIG. 6) Fig. 6 shows a relatively simple method of combining the two measurements. The dial gauges are inserted into the corresponding screwed or clamped flat iron holders (e.g. by set screws). CONNECTION Choose cable cross-sections in accordance with the rated current. Not used cable entries must be closed by compression glands. The terminal box can be turned by 90 or 180. Work should only be carried out by qualified personnel, always with the machine out of operation, disconnected and previously secured against starting. This is also valid for auxiliary circuits (e.g. heaters). Make sure that there is no voltage! The supply cables must be connected with special care to ensure permanent and reliable contact (without loose cable ends); use suitable terminals for the connection cables. Supply cables must be stress-relieved so that no cantilever loads are exerted on the terminals. Ensure a good connection of the protective conductor. The minimum safety distances between conductors and between those and earth should not exceed the following values: 550 V 8 mm; 750 V 10 mm; 1100 V 14 mm. Make sure that no foreign matter is left in the terminal box, and that it is clean and dry. Cable entries which are not used and the terminal box itself have to be sealed dust and water-tight. In order to maintain the degree of protection, always make sure that the original gaskets are used when closing the terminal box. Connect protective conductor here. For the test run without drive elements, secure the key. Before commissioning brake motors, make sure that the brake is operating correctly. DIRECTION OF ROTATION Normally, the motors are suitable for both directions of rotation. Exceptions are indicated on the rating plate by an arrow. For the desired direction of rotation, the stator winding is connected as follows: Connection L1, L2, L3 to Direction of rotation when viewing drive end U1, V1, W1 Clockwise W1, V1, U1 Counter-clockwise Fig. 4 Angular alignment Fig. 5 Parallel alignment (centre offset) Fig. 6 Parallel Angular alignment VIBRATIONS DURING OPERATION Vibration levels V eff = 3.5 mm/s (P N 15 kw) or 4.5 mm/s (P N > 15 kw) of the coupled machine are not problematic. When there are differences in comparison with normal operation, such as higher temperature, noise, vibration, determine the cause and, if necessary, consult the manufacturer. ELETTRICAL Do not switch safety devices off, not even when test running. In the case of doubt, disconnect the machine. INSULATION RESISTANCE (see Check before commissioning ) VOLTAGE AND WINDING CONNECTION The admissible fluctuation between rated voltage and supply voltage is ± 5%; for rated frequency, ±2% is allowed. Observe different connection indications and data on the rating plate, as well as the connection diagram in the terminal box. Check of the direction of rotation, see below. REVERSING THE DIRECTION OF ROTATION Mode of starting and winding Direct-on-line starting and polechanging motors with separate windings Star/delta starting and polechanging motors with Dahlander winding Measures Exchange two supply-cable conductors on the terminal board of the motor Exchange two supply-cable conductors at the incoming supply to the contactor combination TEST To check the direction of rotation, switch the properly connected but uncoupled motor quickly ON/OFF. Y/Δ STARTING In order to avoid excessive transient currents and torques, before changing over from Y to, wait until the starting current of the Y stage has died down or run-up has concluded (e.g. change over when rated speed is reached). OPERATING INSTRUCTIONS FOR THREE-PHASE, SINGLE-PHASE AND BRAKE MOTORS 3006/16 en Ed. 02.2016 2

MOTOR PROTECTION Connect semiconductor temperature detectors to the release device in accordance with the wiring diagram. Continuity test, if necessary, to be carried out by means of a measuring bridge only (max. 2.5 V). In order to achieve full thermal protection, an additional thermally delayed overload protection must be installed (Fig. 7). Normally, fuses alone protect only the supply system not the motor. Example Contactor with over current relay Thermistor protection and fuse MAINTENANCE Fig. 7 Before carrying out any work on the motor, disconnect it and secure it against restarting. Exception: In motors with greasing device, regrease the bearings with the motor running. Caution, danger of accidents: Take care not to come in contact with moving parts! CLEANING Depending on the local conditions, air passages should be cleaned regularly. BEARING LUBRICATION Observance of regreasing intervals is vital for the operational reliability of the motor! If a grease with a different soap base is to be used, clean bearing seats thoroughly. Make sure that the bearing grease used meets the following requirements: Pour point approx. 190 C Ash content 4 % Water content 0.3 % LUBRICANT Grease K 3 N to DIN 51825 (lithium-based, water resistant to DIN 51807 Part 1, grade 0 or 1). Regrease only with a similar grease (e.g. Esso Unirex N 3, Shell-Alvania G 3, Esso Beacon 3, etc.). REPAIR INSTRUCTIONS Any repair work within the guarantee period is subject to the approval of the motor manufacturer. GENERAL It is strongly recommended that only original spares be used for motor repairs. It is work which do not affect the explosion protection and is, therefore, not subject to special regulations. e.g. Replacement of gaskets or joints Repair or replacement of fan or fan cover Replacement of bearings Replacement of terminal board SPECIAL REPAIRS It is work which can affect the explosion protection, e.g. work on stator or rotor windings. Unless the repair is carried our by ourselves, the proper execution of the work in accordance with the relevant regulations must be certified by an authorized expert. According to EN 50019 or EN 50014, any repair of this kind must be stated on an additional plate, permanently fixed to the motor. MAINTENANCE OF BEARINGS BALL BEARING WITH PERMANENT LUBRICATION Under normal operating conditions, motors can be operated for about 20,000 hours without maintenance. However, the maximum period of maintenance-free operation is four years. The ball bearings and the bearing caps should then be washed with petrol or benzene. If necessary, replace the bearings. Fill the spaces between the balls and the roller tracks as well as the grease compartments half with grease. Coat shaft bushings in the bearing caps or endshields with a thin layer of grease. Permanently greased bearings (2RS and 2Z bearings) cannot be washed and regreased. Such bearings must therefore be replaced. To dismantle the bearings, use pressing screws or other appropriate devices. BALL BEARINGS WITH REGREASING DEVICE AND GREASE SLINGER Regreasing interval and required quantity of grease is indicated on the rating plate. Bearings and bearing caps must be washed with petrol or benzene when they have been regreased twelve times. Used petrol or benzene in air-tight tanks should be disposed of as special refuse with the marking «Petrol» or «Benzene». INSTRUCTIONS FOR STORAGE OF MOTORS For prolonged storage of electric motors (e.g. spare motors), the following precautions must be observed: PLACE Make sure that they are kept in a dry and dust free place with minimum vibration (V eff 0.2 mm/s) (damage to stalled bearings). Ambient temperature + 10 C to + 40 C, relative humidity < 50 %. ROTOR LOCKING DEVICE On motors with roller bearings, fix the rotor in place by means of the locking device, to protect the bearings against damage due to vibration. Motors shipped on vibration dampers should also be stored in this condition. Where pulleys, half couplings, etc. are already mounted on the shaft extension, fit the locking device or place the motor on vibration dampers, if possible. Use dampers and locking device also for any future transport of the motor. Afterwards, with the outer bearing cap open but the inner cap screwed on, the rotor should be turned slowly and grease pressed in through the regreasing device until approximately half the empty space between the rolling elements and the roller tracks is filled with grease. OPERATING INSTRUCTIONS FOR THREE-PHASE, SINGLE-PHASE AND BRAKE MOTORS 3006/16 en Ed. 02.2016 3

CHECK BEFORE COMMISSIONING BEARINGS Before commissioning a motor that has been stored for more than 4 years, check the bearings. WIRING DIAGRAMS THREE-PHASE CAGE MOTORS Delta connection For motors without regreasing device, grease has to be renewed or bearings have to be changed after 2 years at the latest. Even minor corrosion can considerably shorten the service life of the bearings. Bearings that need not be replaced should be packed with new grease. For grease type and quantity, refer to the rating plate (on the motor) and to «Bearing lubrication, Lubricant» on page 6 of this Operating Instructions. Star connection Connection to star/delta starter Motors with regreasing device have to be regreased after 2 years at the latest with the double quantity of grease indicated on the nameplate. Hereby the rotor has to be rotated. When motors are stored for over 4 years, change grease. The rotor has to be rotated every month by approx. 30 degrees, in order to avoid compression spots on the bearings due to static load. For rotating the rotor loosen, but not remove the locking device fitted. After the rotation procedure, retighten the locking device. INSULATION RESISTANCE Before commissioning check the insulation resistance. With values 1kW per Volt rated voltage, dry the winding. Three-phase pole-changing motors: In Dahlander connection: In the type designation the low number of poles = high speed is shown first (e.g. BP 100... 4/8) With 2 separate windings: In the type designation the low number of poles = high speed is shown first (e.g. BP 100... 4/8) For pole-changing motors please observe the wiring diagram in the terminal box of the motor. SINGLE-PHASE CAGE MOTORS Check the insulation resistance of each phase against earth by means of a hand-driven generator (max. 630 V DC) until the measured value is constant. The insulation resistance of new windings is above10 MΩ. The resistance can be lowered considerably by moisture. If, at room temperature, the resistance is below 0.5 MW, the winding must be dried. In this case the winding temperature must not exceed 80 C. For drying connect the space heater or another heating device, or apply an AC voltage of 5 or 6 % (connect in delta) of the rated motor voltage to terminals U1 and V1. Repeat the measurement. The motor can be put into operation when the resistance is above 0.5 MΩ. Insulation resistance is temperature-dependent, i.e. if the temperature is increased/decreased by 10 K, the resistance value is halved/doubled, respectively. OPERATING INSTRUCTIONS FOR THREE-PHASE, SINGLE-PHASE AND BRAKE MOTORS 3006/16 en Ed. 02.2016 4

DISPOSAL CODES FOR ELECTRIC MOTORS FROM ENGINEERING INDUSTRY 01/02/2016 CODE OF THE MOTOR (WASTE) DISPOSED IN ALL ITS PARTS EWC (European Waste Code) EWC DESCRIPTION In the event of disposal of the full motor 16.02.14 Discarded equipment In the event of disposal of a disassembled motor: Aluminium parts: flange, cover, terminal box and frame in aluminium 12.01.03 Non-ferrous metal filings and turnings Steel parts: rotor with shaft (both die-cast and with magnets), stator pack with wire windings, cast iron flange and cover, terminal box, brake with magnet, friction disc, springs, etc. 12.01.01 Ferrous metal filings and turnings Plastic parts: fan, fan cover, terminal box, brake cover, shaft protection 12.01.05 Plastics shavings and turnings Electrical components: switches, capacitors, starters, terminal board, etc. 16.02.16 Components removed from discarded equipment OPERATING INSTRUCTIONS FOR THREE-PHASE, SINGLE-PHASE AND BRAKE MOTORS 3006/16 en Ed. 02.2016 5