Fire Dampers Catalogue

Similar documents
Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

BC 03. Fire Dampers FD-GB-30-AS LISTED

PRODUCTS BULLETIN PRODUCTS CATALOGUE

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Fusible Link (replaceable) Horizontal Mount

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SMOKE DAMPER - CLASS F MODEL BMSD

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Fusible Link (replaceable) Horizontal Mount

table of contents PRODUCT SUMMARY 2

MODEL 151B FIRE DAMPER

INSTALLATION INSTRUCTIONS MODEL KFD-555

Motorized Fire Dampers

Fire, Smoke, and Combination Fire Smoke Dampers

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Model FSD-212. Combination FIRE SMOKE DAMPERS

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

CURTAIN TYPE FIRE DAMPER

MOTORIZED VOLUME DAMPER

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2, FS2C2 Fire Damper Models: MD19, MD39, MA19, MA39

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

BC Motorized Fire Smoke Dampers MSFD-GB-30C1-A MSFD-GB-30C1-A LISTED

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SD-1250 and SD-1600 Series Smoke Dampers

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2 Fire Damper Models: MD19, MD39, MA19, MA39

Standard Installation Combination Fire/Smoke Damper Models: FS1(SS), FS2(SS) Fire Damper Models: MD19(SS)

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Standard Installation Fire Damper Models: 319, 319(SS), D39

series FSD-FLD Fire and smoke dampers UL Approval

CFSD Series. Product Description

LLOYD INDUSTRIES INC.

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Installation, Operation and Maintenance Manual

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Installation, Operation and Maintenance Manual

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

MULTI-BLADE FIRE DAMPERS

Part # Installation,Operation and Maintenance Instructions

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

MULTI-BLADE FIRE DAMPERS

SINGLE DUCT TERMINAL UNITS

HCD-230 Industrial Control Damper

ARROW UNITED INDUSTRIES

ARROW INDUSTRIAL PRODUCTS

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

Fire Damper. Grilles Diffusers Dampers Louvers VAV Boxes Sound Attenuators. Spectrum Industries

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Smoke Dampers. Installation Instructions

Installation, Operation and Maintenance Instructions

CURTAIN FIRE DAMPERS GENERAL PRODUCT OVERVIEW

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

When Time is Everything... We Manufacture in Days - Not Weeks!

VCD-23 Low Leakage CONTROL DAMPER

CCS Zone/Bypass Damper Assembly

SECTION AXIAL HVAC FANS

CEILING DAMPERS GENERAL PRODUCT OVERVIEW CEILING DAMPERS MODELS 0716, , 0714 & 0722 FOR SQUARE, RECTANGULAR OR ROUND DUCTS

Model FD Static Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

We make dampers easy for you!

SECTION HVAC POWER VENTILATORS

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

Model VCD-20 3V CONTROL DAMPER

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

SECTION CENTRIFUGAL HVAC FANS

VCD-23. Low Leakage CONTROL DAMPER

YCCS Zone/Bypass Damper Assembly

Nobody delivers dampers and louvers faster!

YCCS Zone/Bypass Damper Assembly

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Transcription:

Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in Qatar

Static & Dynamic Fire s DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) The Fire s have been investigated by UL Laboratories in Chicago - USA on February 12, 2013 in accordance with UL 555 - Standard for Fire s. UNDERWRITERS LABORATORIES' STANDARD UL 555 UL 555 - FIRE DAMPERS Fire s are intended for use where air ducts penetrate or terminate at openings in walls or partitions, in air transfer openings in partitions, and where air ducts extend through floors as specified in the Standard for Installation of Air Conditioning and Ventilating Systems, NFPA 90A. In a fire emergency the Fire is designed to close and prevent the spread of fire from one side of the wall or partition to the other. Fire s are evaluated for use as either: a) Fire s for Static Systems - For HVAC systems that are automatically shut down in the event of a fire. b) Fire s for Dynamic Systems - For HVAC systems that are operational in the event of a fire. c) Combination Fire and Smoke s - For locations in HVAC systems where a Fire and a Smoke are required at a single location. The UL 555 Standard for Fire s includes Significant Test Criteria. Operational Reliability To ensure operation through 250 cycles for dampers for use without actuators, or 20,000 cycles for dampers with actuators and Cycle Testing following Salt Spray Exposure. Fire Endurance For either 1.5 or 3 hours to determine the hourly classification of the damper assembly. Hose Stream Test To verify the damper assembly and associated installation components remain intact during explosive fire conditions. Salt-Spray Exposure To simulate the dust and other debris that accumulates on a fire damper mounted in a duct or opening within a building and to investigate the performance of the Fire while subjected to such accumulations. Dynamic Closure To verify the damper assembly will close against heated air flow velocity of at least 2000 fpm and 4 inches of water. (Not required for s Classified for Static "fans off" Systems). Type of Fire Test Section or Standard Static Fire Dynamic Fire Combination Fire and Smoke 1. Fire Endurance & Hose Stream 10 x x x 2. Operational Reliability 11 x x x 3. Salt-Spray Exposure 12 x x x 4. Spring Closing Force 13 x - - 5. Dynamic Closure 14 - x x 6.Operation UL555S - - x 7. Leakage UL555S - - x x. Test applicable -. Test not applicable 2

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Static Fire s: Page Static Fire (Type A)... 4 Table Of Contents Static Fire (Type B)... 5 Static Fire (Type CR)... 6 Static Fire (Type CO)... 7 Dynamic Fire s: Dynamic Fire (Type A)... 8 Dynamic Fire (Type B)... Dynamic Fire (Type CR)... Dynamic Fire (Type CO)... Fire Installation Instructions: Fire s Installation Instructions... Certificate & Approvals: UL Certificate of Compliance... Civil Defense Approval... 9 10 11 12---16 18-19 20-21 3

12.0 12.0 DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Static Fire s (Type A) Rectangular Code: CRFD-A-S Curtain Rectangular Fire (TYPE A). FOR USE IN STATIC SYSTEMS. 3 HOUR RATING. UL 555 CLASSIFIED Description: The Rectangular Curtain Type Fire provides an efficient solution to separate areas of Fire in Ventilation Systems. The Curtain Type Fire will stop the spread of fire through ducts, walls or floors. Size (Vertical): - Min. size - WxH 100x100mm - Max. size - WxH 900x900mm Size (Horizontal): - Min. size - WxH 100x100mm - Max. size - WxH 900x900mm Features: Casing : - 20 Gage (1.0mm) Galvanized Steel Blades : - 22 Gage (0.8mm) Galvanized Steel Spring : - 301 Stainless Steel Closure Spring. Fusible Link : - 165 ⁰F (74 ⁰C) is Standard. H - 5mm 1 3 2 1 Casing 2 Interlocking Curtain Blades W - 5mm 105 mm 4 3 UL Listed Fusible Link 4 Closure Spring 5 Catch Plate 6 Steel Rivet Ordering example CRFD A S 300X150 7 5 Code Type Static / Dynamic Dim. Width x Height Fire Sleeve: DVAC Fire s Sleeves ensure proper damper mounting in sleeve and can be shipped direct to job site for immediate installation. Note: Sleeves can be field fabricated. H W L Installation: Please refer to Fire Installation Instructions (Page 12---16). Type 'A' - Blades and frame in the airstream Min. size - WxH 100x100mm Max. size - WxH 900x900mm * Materials Used for CRFD: 4

12.0 12.0 DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Static Fire s - Type B Rectangular Code: CRFD-B-S Curtain Rectangular Fire (TYPE B). FOR USE IN STATIC SYSTEMS. 3 HOUR RATING. UL 555 CLASSIFIED Description: The Rectangular Curtain Type Fire provides an efficient solution to separate areas of Fire in Ventilation Systems. The Curtain Type Fire will stop the spread of fire through ducts, walls or floors. Size (Vertical): - Min. size - WxH 100x100mm - Max. size - WxH 900x800mm Size (Horizontal): - Min. size - WxH 100x100mm - Max. size - WxH 900x800mm Features: Casing : - 20 Gage (1.0mm) Galvanized Steel Blades : - 22 Gage (0.8mm) Galvanized Steel Spring : - 301 Stainless Steel Closure Spring. Fusible Link : - 165 ⁰F (74 ⁰C) is Standard. Height (H) Dim. (A) 100 thru 400mm 50mm 410 thru 650mm 75mm 660 thru 800mm 100mm A H - 5mm 1 3 2 1 Casing 2 Interlocking Curtain Blades W - 5mm 105 mm 4 3 UL Listed Fusible Link 4 Closure Spring 5 Catch Plate 6 Steel Rivet Ordering example CRFD B S 300X150 7 5 Code Type Static / Dynamic Dim. Width x Height Fire Sleeve: DVAC Fire s Sleeves ensure proper damper mounting in sleeve and can be shipped direct to job site for immediate installation. Note: Sleeves can be field fabricated. A H W L Installation: Please refer to Fire Installation Instructions (Page 12---16). Type 'B' - Blades partially in airstream Min. size - WxH 100x150mm Max. size - WxH 900x900mm * Materials Used for CRFD: 5

12.0 12.0 DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Static Fire s - Type CR Round Code: CRFD-CR-S Curtain Round Fire (TYPE CR). FOR USE IN STATIC SYSTEMS. 3 HOUR RATING. UL 555 CLASSIFIED Description: The Round Curtain Type Fire provides an efficient solution to separate areas of Fire in Ventilation Systems. The Curtain Type Fire will stop the spread of fire through ducts, walls or floors. Size (Vertical): - Min. size - WxH 150mm Diameter - Max. size - WxH 750mm Diameter Size (Horizontal): - Min. size - WxH 150mm Diameter - Max. size - WxH 750mm Diameter Features: Casing : - 20 Gage (1.0mm) Galvanized Steel Blades : - 22 Gage (0.8mm) Galvanized Steel Spring : - 301 Stainless Steel Closure Spring. Fusible Link : - 165 ⁰F (74 ⁰C) is Standard. Diameter (D) Height (H) Width (W) 150 thru 400mm +75mm +50mm 410 thru 550mm +125mm +50mm 560 thru 750mm +150mm +50mm Diameter (D) Collar Thickness 150 thru 400mm 22 Gage (0.8mm) 410 thru 750mm 20 Gage (1.0mm) H D 1 2 1 Casing W 105 mm 3 2 Interlocking Curtain Blades 4 3 UL Listed Fusible Link 4 Closure Spring 5 Catch Plate Ordering example CRFD CR S 300 6 5 6 Steel Rivet Code Type Static / Dynamic D = Diameter Fire Sleeve: DVAC Fire s Sleeves ensure proper damper mounting in sleeve and can be shipped direct to job site for immediate installation. Note: Sleeves can be field fabricated. H W L Installation: Please refer to Fire Installation Instructions (Page 12---16). Type 'CR' - Blades partially in airstream Min. size - WxH 250x250mm Max. size - WxH 900x900mm * Materials Used for CRFD: 6

12.0 12.0 12.0 Static Fire s - Type CO Flat Oval DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Code: CFOFD-CO-S Curtain Flat Oval Fire (TYPE CO). FOR USE IN STATIC SYSTEMS. 3 HOUR RATING. UL 555 CLASSIFIED Description: The Flat Oval Curtain Type Fire provides an efficient solution to separate areas of Fire in Ventilation Systems. The Curtain Type Fire will stop the spread of fire through ducts, walls or floors. Size (Vertical): - Min. size - 150mm Minor or Major Axis - Max. size - 750mm Minor or Major Axis Size (Horizontal): - Min. size - 150mm Minor or Major Axis - Max. size - 750mm Minor or Major Axis Features: Casing : - 20 Gage (1.0mm) Galvanized Steel Blades : - 22 Gage (0.8mm) Galvanized Steel Spring : - 301 Stainless Steel Closure Spring. Fusible Link : - 165 ⁰F (74 ⁰C) is Standard. Minor Axis (Mi) Height (H) 150 thru 400mm +75mm 410 thru 550mm +125mm 560 thru 750mm +150mm Minor Axis (Mi) Collar Thickness 150 thru 400mm 22 Gage (0.8mm) 410 thru 750mm 20 Gage (1.0mm) H Ma Mi W= Major Axis + 50mm 105 mm 1 2 1 Casing 3 2 Interlocking Curtain Blades 4 3 UL Listed Fusible Link 4 Closure Spring 5 Catch Plate Ordering example CFOFD CO S 300 6 5 6 Steel Rivet Code Type Static / Dynamic D = Diameter Fire Sleeve: DVAC Fire s Sleeves ensure proper damper mounting in sleeve and can be shipped direct to job site for immediate installation. Note: Sleeves can be field fabricated. H W L Installation: Please refer to Fire Installation Instructions (Page 12---16). Type 'CR' - Blades partially in airstream Min. size - WxH 350x250mm Max. size - WxH 900x800mm * Materials Used for CFOFD: 7

12.0 12.0 DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Dynamic Fire s - Type A Rectangular Code: CRFD-A-D Curtain Rectangular Fire (TYPE A). FOR USE IN DYNAMIC SYSTEMS. 3 HOUR RATING. UL 555 CLASSIFIED Description: The Rectangular Curtain Type Fire provides an efficient solution to separate areas of Fire in Ventilation Systems. The Curtain Type Fire will stop the spread of fire through ducts, walls or floors. There is a wide choice of sizes available for Low, Medium and High Velocity applications. The s are fitted with standard release 74⁰C fusible links. Ratings: - Pressure : Up to 4"w.g. (Up to 1000 Pa) - Velocity : Up to 2000 fpm (Up to 10.16 m/s) Size (Vertical): - Min. size - WxH 100x150mm - Max. size - WxH 900x900mm Features: Casing : - 20 Gage (1.0mm) Galvanized Steel Blades : - 22 Gage (0.8mm) Galvanized Steel Spring : - 301 Stainless Steel Closure Spring. Fusible Link : - 165 ⁰F (74 ⁰C) is Standard. H - 5mm 1 2 1 Casing W - 5mm 105 mm 3 2 Interlocking Curtain Blades 4 3 UL Listed Fusible Link 4 Closure Spring 5 Catch Plate Ordering example CRFD A D 300X150 6 7 5 6 50mm, 18 Gage (1.2mm) GI Flat 7 Steel Rivet Code Type Static / Dynamic Dim. Width x Height Fire Sleeve: DVAC Fire s Sleeves ensure proper damper mounting in sleeve and can be shipped direct to job site for immediate installation. Note: Sleeves can be field fabricated. H W L Installation: Please refer to Fire Installation Instructions (Page 12---16). Type 'A' - Blades and frame in the airstream Min. size - WxH 100x150mm Max. size - WxH 900x900mm * Materials Used for CRFD: 8

12.0 12.0 DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Dynamic Fire s - Type B Rectangular Code: CRFD-B-D Curtain Rectangular Fire (TYPE B). FOR USE IN DYNAMIC SYSTEMS. 3 HOUR RATING. UL 555 CLASSIFIED Description: The Rectangular Curtain Type Fire provides an efficient solution to separate areas of Fire in Ventilation Systems. The Curtain Type Fire will stop the spread of fire through ducts, walls or floors. There is a wide choice of sizes available for Low, Medium and High Velocity applications. The s are fitted with standard release 74⁰C fusible links. Ratings: - Pressure : Up to 4"w.g. (Up to 1000 Pa) - Velocity : Up to 2000 fpm (Up to 10.16 m/s) Size (Vertical): - Min. size - WxH 100x100mm - Max. size - WxH 900x800mm Features: Casing : - 20 Gage (1.0mm) Galvanized Steel Blades : - 22 Gage (0.8mm) Galvanized Steel Spring : - 301 Stainless Steel Closure Spring. Fusible Link : - 165 ⁰F (74 ⁰C) is Standard. Height (H) Dim. (A) 100 thru 400mm 50mm 410 thru 650mm 75mm 660 thru 800mm 100mm A H - 5mm 1 2 1 Casing W - 5mm 105 mm 3 2 Interlocking Curtain Blades 4 3 UL Listed Fusible Link 4 Closure Spring 5 Catch Plate Ordering example CRFD B D 300X150 6 7 5 6 50mm, 18 Gage (1.2mm) GI Flat 7 Steel Rivet Code Type Static / Dynamic Dim. Width x Height Fire Sleeve: DVAC Integral Sleeve Fire s ensure proper damper mounting in sleeve and can be shipped direct to job site for immediate installation. Note: Sleeves can be field fabricated. A H W L Installation: Please refer to Fire Installation Instructions (Page 12---16). Type 'B' - Blades partially in airstream Min. size - WxH 100x150mm Max. size - WxH 900x900mm * Materials Used for CRFD: 9

12.0 12.0 DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Dynamic Fire s - Type CR Round Code: CRFD-CR-D Curtain Round Fire (TYPE CR). FOR USE IN DYNAMIC SYSTEMS. 3 HOUR RATING. UL 555 CLASSIFIED Description: The Round Curtain Type Fire provides an efficient solution to separate areas of Fire in Ventilation Systems. The Curtain Type Fire will stop the spread of fire through ducts, walls or floors. There is a wide choice of sizes available for Low, Medium and High Velocity applications. The s are fitted with standard release 74⁰C fusible links. Ratings: - Pressure : Up to 4"w.g. (Up to 1000 Pa) - Velocity : Up to 2000 fpm (Up to 10.16 m/s) Size (Vertical): - Min. size - 150mm Diameter - Max. size - 750mm Diameter Diameter (D) Height (H) Width (W) 150 thru 400mm +75mm +50mm 410 thru 550mm +125mm +50mm 560 thru 750mm +150mm +50mm Features: Casing : - 20 Gage (1.0mm) Galvanized Steel Blades : - 22 Gage (0.8mm) Galvanized Steel Spring : - 301 Stainless Steel Closure Spring. Fusible Link : - 165 ⁰F (74 ⁰C) is Standard. Diameter (D) Collar Thickness 150 thru 400mm 22 Gage (0.8mm) 410 thru 750mm 20 Gage (1.0mm) H D 1 2 1 Casing W 105 mm 3 2 Interlocking Curtain Blades 4 3 UL Listed Fusible Link 4 Closure Spring 5 Catch Plate Ordering example CRFD CR D 300 6 5 6 Steel Rivet Code Type Static / Dynamic D = Diameter Fire Sleeve: DVAC Integral Sleeve Fire s ensure proper damper mounting in sleeve and can be shipped direct to job site for immediate installation. Note: Sleeves can be field fabricated. H W L Installation: Please refer to Fire Installation Instructions (Page 12---16). Type 'CR' - Blades partially in airstream Min. size - WxH 250x250mm Max. size - WxH 900x900mm * Materials Used for CRFD: 10

12.0 12.0 DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Dynamic Fire s - Type CO Flat Oval Code: CFOFD-CO-D Curtain Flat Oval Fire (TYPE CO). FOR USE IN DYNAMIC SYSTEMS. 3 HOUR RATING. UL 555 CLASSIFIED Description: The Flat Oval Curtain Type Fire provides an efficient solution to separate areas of Fire in Ventilation Systems. The Curtain Type Fire will stop the spread of fire through ducts, walls or floors. There is a wide choice of sizes available for Low, Medium and High Velocity applications. The s are fitted with standard release 74⁰C fusible links. Ratings: - Pressure : Up to 4"w.g. (Up to 1000 Pa) - Velocity : Up to 2000 fpm (Up to 10.16 m/s) Size (Vertical): - Min. size - 150mm Minor or Major Axis - Max. size - 750mm Minor or Major Axis Features: Casing : - 20 Gage (1.0mm) Galvanized Steel Blades : - 22 Gage (0.8mm) Galvanized Steel Spring : - 301 Stainless Steel Closure Spring. Fusible Link : - 165 ⁰F (74 ⁰C) is Standard. Minor Axis (Mi) Height (H) 150 thru 400mm +75mm 410 thru 550mm +125mm 560 thru 750mm +150mm Minor Axis (Mi) Collar Thickness 150 thru 400mm 22 Gage (0.8mm) 410 thru 750mm 20 Gage (1.0mm) H Ma Mi W= Major Axis + 50mm 105 mm 1 2 1 Casing 3 2 Interlocking Curtain Blades 4 3 UL Listed Fusible Link 4 Closure Spring 5 Catch Plate Ordering example CFOFD CO D 300 6 5 6 Steel Rivet Code Type Static / Dynamic D = Diameter Fire Sleeve: DVAC Integral Sleeve Fire s ensure proper damper mounting in sleeve and can be shipped direct to job site for immediate installation. Note: Sleeves can be field fabricated. H W L Installation: Please refer to Fire Installation Instructions (Page 12---16). Type 'CR' - Blades partially in airstream Min. size - WxH 350x250mm Max. size - WxH 900x800mm * Materials Used for CFOFD: 11

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Fire s Installation Instructions Rectangular Code: CRFD (Type: A & B) INSTALLATION INSTRUCTIONS 1.) Wall/Floor Opening and Clearance Required The Opening in wall or floor shall be larger than the fire sleeve due to the expansion during periods of intense heat. - Minimum clearance required is 10mm per linear meter for Width & Height. - Sleeve may rest on Bottom of the opening. Wall/Floor opening d 1 Height Height w/ Sleeves Breakaway Joints Width Width d 2 d 3 d 4 d = 10mm * (Height/1000mm) 1 d = 10mm * (Width/1000mm) 2 where : d = d + d 2 3 4 2.) sleeve connections listed in UL 555, Sixth Edition, Standard for Fire s Plain S Slip Hemmed S Slip Inside Slip Joint Double S Slip Standing S Slip Standing S Slip (Alternate Bar) Standing S Slip (Angle Reinforced) Standing S Slip (Bar Reinforced) The breakaway connections shown in fig. above can be applied with maximum 2 nos. # 10 sheet metal screw on each side and on the bottom located in the center of the slip pocket and penetrating both sides of the slip pocket. The illustrated joint above can be applied as the top and bottom joints and the sides with a drive slip joint as long as the duct height is less than 500mm. Drive Slip Joint * Materials Used for CRFD: 12

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Fire s Installation Instructions Rectangular Code: CRFD (Type: A & B) Slip-on Flange System: UL tested Slip-on Flange System are approved as breakaway connection when installed as shown below: 150mm Long, 1.59mm Maximum thickness plastic cleats 305 mm C-C (Minimum: 1 per side) Flanged System angles (Attached per manufacturers instruction) Do not bolt corners Neoprene gasket between all angles 3.) Sleeve Thickness & Length All Fire s must be installed in a sleeve of the required gauge and length. It could be factory Installed or field fabricated. - Sleeve shall extend a maximum of 150mm from the wall or floor opening from each side. - Sleeve may extend with a maximum length of 400mm from wall or floor if a factory installed access door is required). Type of Connection Dimension Sleeve Thickness Rigid or Breakaway All Sizes 2mm Rigid or Breakaway Maximum width 900mm 1.5mm Maximum height 600mm Up to 300mm 0.55mm 301 to 750mm 0.7mm Breakaway Only 751 to 1350mm 0.85mm 1351 to 2100mm 1.0mm 2001 and up 1.2mm N.B.: Any connection other than breakaway is considered rigid. * Materials Used for CRFD: 13

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Fire s Installation Instructions Rectangular Code: CRFD (Type: A & B) 4.) -Sleeve Attachment All four sides of the damper frame must be attached to the sleeve with one row of attachments on each sides of the blade channel. Attachment must be spaced a maximum of 150mm on centers and a max of 50mm from corners and minimum of 4 attachments per side with a total of 16. Secure damper to sleeve with 12mm long welds 50mm Weld 150mm 5.) Securing the fire damper sleeve to the Opening Centerline of the Fire blade should be positioned within the confines of the wall or floor opening. Fire and Sleeve assembly must be installed in opening using retaining angles on each side of the wall or floor. Retaining angle thickness should be 1.5mm minimum Retaining angles should be secured to the damper sleeve ONLY. Retaining angles should cover the gap + 25mm overlap with the wall Retaining angles should be attached to 4 (four) sides of the damper sleeve using 6mm bolts & nuts methods with a maximum spacing of 50mm from corners and 150mm on center. Wall or Floor Retaining Angle Min. 25mm overlay Sleeve 50mm Sleeve 150mm 150mm 50mm * Materials Used for CRFD: 14

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Fire s Installation Instructions Rectangular, Round & Flat Oval Code: CRFD (Type: A, B, CR & CO) Vertical mount without factory mounted sleeve See Section 1 Wall or floor Wall or floor See Section 3 Wall or floor See Section 3 Retaining angle leg shall not exceed 178mm Sleeve On types CR & CO factory furnished duct collar qualifies as breakaway connection, see Section 5 Sleeve Retaining Angles (See Section 5) Sleeve (See Section 3 & 4) TYPE A TYPE B TYPE CR & CO Note: When s installed vertically, the blade stack must be on the top. Horizontal mount without factory mounted sleeve See Section 3 Retaining Angles (See Section 5) Wall or floor See Section 3 Retaining Angles (See Section 5) Wall or floor Wall or floor See Section 3 Sleeve (See Section 3 & 4) See Section 3 Sleeve (See Section 3 & 4) On types CR & CO factory furnished duct collar qualifies as breakaway connection, see Section 5 Sleeve TYPE A TYPE B TYPE CR & CO Note: When s installed horizontally, the ramp must be positioned up as shown in above drawings. * Materials Used for CRFD: 15

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Fire s Installation Instructions Rectangular, Round & Flat Oval Code: CRFD (Type: A, B, CR & CO) Vertical mount with factory mounted sleeve See Section 5 Wall or floor Wall or floor See Section 3 Max. 150mm Wall or floor Max. 150mm See Section 3 On types CR & CO factory furnished duct collar qualifies as breakaway connection. Retaining Angles (See Section 5) TYPE A TYPE B TYPE CR & CO Note: When s installed vertically, the blade stack must be on the top. Horizontal mount with factory mounted sleeve See Section 3 Retaining Angles (See Section 5) Wall or floor See Section 3 Retaining Angles (See Section 5) Wall or floor Wall or floor See Section 3 Sleeve (See Section 3 & 4) See Section 3 Sleeve (See Section 3 & 4) On types CR & CO factory furnished duct collar qualifies as breakaway connection, see Section 5 Sleeve TYPE A TYPE B TYPE CR & CO Note: When s installed horizontally, the ramp must be positioned up as shown in above drawings. * Materials Used for CRFD: 16

Fire s UL Certificate And Civil Defense Approval DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval Fire s Catalogue UL 555 Classified 2013 17

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Fire s Catalogue 18

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) 19

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Fire s Catalogue 20

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) 21

Remarks: DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117 22

Remarks: DOHA - QATAR - PHONE: +974-44500118 - +974-44500119 - FAX: +974-44500117 23

DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) Small Industries Zone - Pink Area Zone 81 - Street 13 - Bldg. 57 Tel: +974 445 00 118-445 00 119 Fax: +974 445 00 117 P.O. Box: 55619 - Doha, State Of Qatar Email: info@dvac-duct.com Website: www.dvac-duct.com