Motorized Fire Dampers

Similar documents
SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

CFSD Series. Product Description

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

SMOKE DAMPER - CLASS F MODEL BMSD

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

FSD60/MFSD60 Multi-blade Fire Damper

Dampers. Louvers. Caring for Human Life & Property (FIRE, SMOKE & HVAC) NAFFCOFlow.com

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-230 Industrial Control Damper

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

VCD-23 Low Leakage CONTROL DAMPER

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

ARROW INDUSTRIAL PRODUCTS

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

MOTORIZED VOLUME DAMPER

VCD-23. Low Leakage CONTROL DAMPER

BC Motorized Fire Smoke Dampers MSFD-GB-30C1-A MSFD-GB-30C1-A LISTED

Thermal Isolation. Break

ARROW UNITED INDUSTRIES

Fire Dampers Catalogue

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

VCD-23. Flange Options. Size Limitations

Model VCD-20 3V CONTROL DAMPER

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

Model VCD-43 Extruded Airfoil Blade Control Damper

Fusible Link (replaceable) Horizontal Mount

SD-1250 and SD-1600 Series Smoke Dampers

L O U V E R S & D A M P E R S

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

Fusible Link (replaceable) Horizontal Mount

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Fire, Smoke, and Combination Fire Smoke Dampers

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

AIR CONDITIONING PRODUCTS COMPANY

series FSD-FLD Fire and smoke dampers UL Approval

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

BC 03. Fire Dampers FD-GB-30-AS LISTED

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

When Time is Everything... We Manufacture in Days - Not Weeks!

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

CURTAIN TYPE FIRE DAMPER

Installation, Operation and Maintenance Manual

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

Marine Fire and Gas Dampers

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

AIR DUCT ACCESSORIES

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

HVAC Control & Balancing Dampers

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

Installation, Operation and Maintenance Manual

Zero Leakage Isolation Damper

Series HCD Airfoil Control Damper

MULTI-BLADE FIRE DAMPERS

LOW LEAKAGE VOLUME CONTROL DAMPER

MULTI-BLADE FIRE DAMPERS

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

Introduction to Johnson Controls Dampers

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

VOLUME CONTROL DAMPERS

Variable Air Volume Dampers

SECTION CONTROL DAMPERS

Transcription:

Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and Dynamic OPTIMA make Motorized Fire damper Model OMFD-611 facilitate isolating compartments of Fire in Ventilation systems in the event of fire. These dampers block the spread of fire through ducts, partition walls or floors. This high performance fire isolating damper with actuator offer an effective barrier maintaining integrity in a fire situation and this is combined with low leakage characteristic for smoke management. It is suitable for installation in sheet metal ductworks or in walls or ceiling slabs made from concrete, brick or light weight partition walls. Standard construction : FRAME: Frame material is GI steel sheet 16 ga., Z-27 as per standard ASTM653. Frame is a welded construction at corners and protected by antirust zinc rich primer coating. BLADES: High quality, 3V formed GI steel sheet blades 1.5 mm thick. Bottom blade width to suit the height of the damper. Dampers up to 220 mm are single blade fabrication. JAMB SEALS: Compression type SS grade 304, side seals to allow free movement of blade and ensure low leakage. TIP SEALS: Graphite/ silicon rubber blade tip seals are standard. LINKAGES: Plated or GI steel, face Linkage parallel blade operation. BUSHES: Fire resistant Brass / Bronze sintered bushes (iolite). JACK SHAFT: 12 mm diameter Zinc Electroplated round shaft. BLADE AXLES: 12 mm diameter zinc electroplated mild steel BLADE STOP: 18 ga. (1.2 mm) galvanized steel sheet angle. FUSIBLE LINK: Standard fusible link 165 deg F (72 deg C) UL Listed. Thermo-electric tripping device available upon request. ACTUATOR: BELIMO spring return (UL classified) 24V / 230V actuator. SIZE: Minimum size - 150 mm x 150 mm Maximum size - 900 mm x 900 mm as single section. Larger sizes can be supplied as Multiple sections. Each section operates independent. UNDERSIZED: ¼ under ordered size unless specified exact or actual size. VARIANTS: A Flange type (flange on both sides) A1 Flange type (flange and sleeve on opposite sides) Material: Available in Stainless steel as option. NOTE: FC FAIL CLOSE - Standard supply FO - FAIL OPEN optional RIGHT SIDE ACTUATOR standard supply LEFT SIDE ACTUATOR - optional

Model : OMFD-611 (Fusible link and spring return actuator) Motorized Fire / Smoke Dampers

Motorized Fire and Smoke Dampers Model : MSFD-651 (Thermo-electric tripping device and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and Dynamic. OPTIMA make Motorized Fire and Smoke damper Model OMSFD-651 facilitate isolating compartments of Fire and smoke in Ventilation systems in the event of fire. These dampers block the spread of fire and smoke through ducts, partition walls or floors. This high performance fire isolating damper with actuator offer an effective barrier maintaining integrity in a fire situation and this is combined with low leakage characteristic for smoke management. It is suitable for installation in sheet metal ductworks, walls or ceiling slabs made from concrete, brick or light weight partition walls. Fire and Smoke damper with actuator ensures lowest resistance to airflow in HVAC systems with airflow velocity to 2000 fpm(10.2 m/sec), 4 w.g (1000Pa) in either direction. Standard construction : FRAME: Frame material is GI steel sheet 16 ga., 108 mm deep, Z-27 as per standard ASTM653. Frame is a welded construction at corners and protected by antirust zinc rich primer coating. BLADES: High quality, 3V formed GI steel sheet blades 1.5 mm thick. Bottom blade width to suit the height of the damper. Dampers up to 250 mm will be single blade construction. JAMB SEALS: Compression type SS grade 304, side seals to allow free movement of blade and ensure low leakage. Tip Seals: High temperature resistant extruded silicone rubber blade edge seals to block leakage of smoke thru dampers. (Graphite tip seals are optional) LINKAGES: Electroplated or GI steel, opposed blade operation. Linkage concealed inside the frame. BUSHES: Fire resistant Brass or Bronze sintered bushes (iolite). SLEEVE: 1.2 mm thick GI steel sheet, 400 mm wide bolted or welded to frame. DRIVE SHAFT: 12.5 mm diameter square / hexagonal Zinc Electroplated shaft, extending 114 mm for actuator mounting. BLADE AXLES: 12 mm diameter zinc plated shaft steel bar. BLADE STOP: 18 ga. (1.2 mm) galvanized steel sheet angle. TRD: Thermal Reset Device 165 deg F (72 deg C) UL Listed. ACTUATOR: BELIMO or HONEYWELL - UL classified actuator SIZE: Minimum size - 200 mm x 150 mm Maximum size - 914 mm x 914 mm as single section. Larger sizes can be supplied as Multiple sections. Each section operates independent. UNDERSIZED: ¼ under ordered size unless specified exact or actual size. OPTIONAL: Material: Available in Stainless steel grade 304. Sleeves: GI sleeves of suitable thickness as per NFPA table 3-4.6.3 can be factory mounted secured to frame cover by equally spaced M6 bolt nuts on all four sides. Standard sleeve 400 mm depth x 20 ga. Thermal Reset Device: 212 deg. F., 250 deg. F., 350 deg. F. available as optional. Retaining Angles: Minimum 35 mm x 35 mm x 2.5 mm available on request. Limit Switches: For BMS remote operation, open-close indication. Indicator: Externally mounted open-close operation. NOTE: FC FAIL CLOSE - Standard supply - FO - FAIL OPEN optional - RIGHT SIDE ACTUATOR standard supply LEFT SIDE ACTUATOR - optional

Model : MSFD-651 (Thermo-electric tripping device and spring return actuator)

Motorized Smoke Dampers Model : OMSD-671 GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Dynamic closure and leakage class II. OPTIMA make Motorized Smoke Dampers OMSD 671 facilitate isolating compartments of smoke in the event of fire in Ventilation systems. These dampers block the spread of smoke through openings in walls, through ducts and floors. Smoke dampers are also alternatively applied as passageway for smoke extraction through shafts of the buildings with smoke extraction fans installed at specified places in the building/roof. In the event of fire, with smoke extraction system, staircase, corridors should remain free for safe exit of people. With the help of extraction fans, an air flow and pressure is created such that poisonous smoke is extracted through shafts. This high performance smoke damper with actuator ensures lowest resistance to airflow in HVAC systems with velocity to 2000 fpm (10.2 m/sec) and 4 w.g (1000 Pa) and is suitable for airflow and leakage in either direction. Standard Construction : FRAME: Frame material is GI steel sheet 16 ga. (1.5 mm), 108 mm deep, Z-27 as per standard ASTM653. Frame is a welded construction at corners and protected by antirust zinc rich primer coating. BLADES: High quality, 3V formed GI steel sheet blades 1.5 mm thick. Bottom blade width to suit the height of the damper. Dampers up to 250 mm will be single blade construction. JAMB SEALS: Compression type SS grade 304, side seals to allow free movement of blade and ensure low leakage. LINKAGES: Plated or galvanized steel, opposed blade operation. Linkage concealed inside the frame. Drive blade has 1 to 5 (125 mm) extendable shaft to mount actuator BUSHES: Fire resistant Brass or Bronze sintered bushes (iolite). BLADE AXLES: 12 mm diameter zinc electroplated shaft steel bar. Tip Seals: High temperature resistant extruded silicone rubber blade edge seals to block leakage of smoke thru dampers. BLADE STOP: 18 ga. (1.2 mm) galvanized steel sheet angle. ACTUATOR: Honeywell or Belimo (UL classified) actuator SIZE: Minimum size - 150 mm x 150 mm Maximum size - 914 mm x 914 mm as single section. Larger sizes can be supplied as Multiple sections. Each section operates independent. UNDERSIZED: ¼ under ordered size unless specified exact or actual size. OPTIONAL: Material: Available in Stainless steel, as requested. Sleeves: GI sleeves of suitable thickness as per NFPA table 3-4.6.3 can be factory mounted secured to frame cover by equally spaced M6 bolt nuts on all four sides. Standard sleeve 300 mm depth x 20 ga. Retaining Angles: Minimum 35 mm x 35 mm x 2.5 mm available on request. Limit Switches: For BMS remote operation, open-close indication. Indicator: Externally mounted open-close operation. NOTE: FC FAIL CLOSE - Standard supply, FO - FAIL OPEN optional RIGHT SIDE ACTUATOR standard supply, LEFT SIDE ACTUATOR - optional

Motorized Smoke Dampers Model : OMSD-671