Suitable for all water based foam applications. Unique IMA Sensing technology ensures reliability. Increases throughput by reducing downtime

Similar documents
Mobrey MSM400 Ultrasonic sludge density measurement system

Level and Flow Measurement. Sludge Finder 2

Dosing pump series G A

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

ROTARY Point Level Measurement for Inventory Control

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Controller Specification Sheet

Mobrey dry products level measurement and control

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

MD x230V. Grundfos Pump GRUNDFOS DATA BOOKLET

Mobrey 003 Ultrasonic Liquid Level Switch

DIAMOND POINT VIBRATING PROBES

MD x400V. Grundfos pump GRUNDFOS DATA BOOKLET

CleverLevel level switches. The really clever alternative to vibrating forks.

Free Fall Fire Valve Range & Accessories

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Level limit switch Series RF 3000 Selection list

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

CONTENTS DIVERSE. Preface SQUEEZE ANALYSER SQA2 RESISTANCE WELDING FORCE MONITOR. Resistance Welding. Squeeze Analyser OPERATING INSTRUCTIONS

TORRIX Magnetostrictive level sensor

HBLT-Wire LEVEL SENSOR For analogue measurements of NH3 and HFC in refrigeration systems

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

NT-500 Technical Support Guide. For use by qualified company approved Technicians

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

For installation instructions refer to the mounting and dimensions details and the terminal layout drawings on page 5 of this manual.

TERMINATOR User Manual

CVR-625. Compact Vibrating Rod Instruction Manual

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Series 500. Liquid Level Transmitters. Instruction Manual

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Pressure transducer DMU 01K Compact version

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Level Limit Switch liquiphant FTL 360 / FTL 361

Valves For Cryogenic Applications

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

F-2700 SERIES INSERTION VORTEX FLOW METER

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

ISTEC MAGNETIC METERS

INTELEPOWER CX COMMUNICATIONS SYSTEMS

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Professional Wireless Products

F-1500 SERIES INSERTION TURBINE FLOW METER

User Manual 123electric Battery Management System 123\BMS Revision 1.4 Augusts 2015

Mobrey Squitch 2 Ultrasonic Liquid Level Switch

Level Limit Switch liquiphant FTL 365 / FTL 366

ProcessAutomatic EZ-Mag

SM361 RIG SWITCH CONSTRUCTION MANUAL

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

OPTISWITCH 4000/5000. Vibration level switches for liquids

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

유량계전문제조업체. Electro Magnetic FLOWMETER

Gladiator. Acoustic Switch & Auto Spray Cleaner. Data Sheet. A Higher Level of Performance. Non-contact Self Cleaning Blocked Chute Detection

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Optidew Vision Optical Dew-Point Meter

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

AZM300 More than just a solenoid interlock

CAPACITIVE LEVEL CONTROLS SC - SCD SERIES

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps

ONYX VALVE. Pressure Isolator Ring. New Patented Design Assures Accuracy and Maintenance-Free Operation Patent #5,708,201

Rosemount 2160 Wireless Vibrating Fork Liquid Level Switch

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

A new era in asset protection

OPTISWITCH 6500 C Technical Datasheet

K25000 & KD25000 Series

P U L S A R point 210

RTD Elements c/w tails.

R F C a p a c i t a n c e TrueCap

The Mobrey product range provides reliable point level detection in a variety of dry solid applications

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

CONDUCTIVITY LEVEL LIMIT SWITCH User s Manual

INTELEPOWER CXS SWITCHING SYSTEMS

BASIC ELECTRICAL MEASUREMENTS By David Navone

Plug Into the Current Future

Customised drive solutions

Plug Into the Current Future

MODEL 422 Submersible Pump Controller

Flow Controller, flow control system for gases

Z4-Series DREXELBROOK DATA SHEET. Easy-Installation. Z-tron IV Point Level Switch, a reliable low-cost, on/off level switch.

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

L5000 Plus. Installation & Setup Guide

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

What is the secret to our success?

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

6109A / 7109A. Portable Calibration Baths. Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators

Model DS1000/DT20 System

A softstarter beyond the ordinary

Build Your Own Electric Car Or Truck

IEC Limit Switches Selection Guide

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

F-2700 SERIES INSERTION VORTEX FLOW METER

Transcription:

Let Charis Technology supply the answer to your expensive water based foam problems with the SureSense range of Foam and Foam and Level Control Systems... Suitable for all water based foam applications Efficient, microprocessor control Proven technology Unique IMA Sensing technology ensures reliability Cuts antifoam costs Increases throughput by reducing downtime Hygienic and steam-sterillisable sensors Large range of fittings to suit all sizes and make of vessel Range of enclosures; Wall, Rack, Benchtop. Suitable for use in hazardous areas Both Foam Control and Foam and Level Control Systems available Charis Technology Ltd Unit J, Altbarn Close, Revenge Road, Chatham, Kent ME5 8UD Tel: +44 (0)1622 751731 Fax: +44 (0)1622 688922 Website: www..uk.com Email: sales@.uk.com

Foam Control Systems Charis Technology SureSense Range of Foam Control Systems for use in water-based foam applications The SureSense range of water based foam control systems provide an efficient, reliable and cost-effective solution to foam control in a diverse collection of industries where the production and control of foam causes a problem. Foam generation can cause a variety of expensive and time consuming problems. Excess foam can severely limit throughput of product in a process, there can be high cost implications in clearing up and loss of production should foam overflow, and there is a possibility of pollution and damage to equipment if the situation were to become critical. Whilst the addition of antifoam may solve the problem it is difficult to know when to add it to the process so it tends to be added in quantities based on maximum demand, which is not only extremely expensive but wasteful as well.. The SureSense range allows for the accurate control of foam by sensing when the foam reaches an unacceptable level and then adding the antifoam agent as and when needed rather than continually. This not only increases the efficiency of the process it also saves money on expensive antifoam. All Charis Technology Foam Control Systems benefit from the unique IMASensing technology which allows the sensor to continue functioning accurately even when fouled with residual foam or product, thus providing efficient operation with minimum maintenance. SureSense Foam Control Systems are in use around the world to effectively control water based foam in Biotech, Waste Water, Food Production, Pharmaceutical, Sugar, Brewing and other similar applications. We hope you find the information in this file useful and should you wish to take your enquiry further please don t hesitate to contact Charis Sales on +44 (0)1622 751731. Charis Technology Ltd Unit J, Altbarn Close, Revenge Road, Chatham, Kent ME5 8UD Tel: +44 (0)1622 751731 Fax: +44 (0)1622 688922 Website: www..uk.com Email: sales@.uk.com

Foam Sensors Charis Technology s SureSense Sensors, when used with an appropriate Charis Foam Controller, provide efficient and cost effective foam control over a wide range of water based process applications. Although outwardly similar, each stainless steel sensor can be customised to suit the client s needs. Different heads, process fittings and lengths are available making Charis sensors the first choice for many applications throughout the world. The sensors are hygienic and steam sterillisable, and thanks to Charis s patented IMA Sensing technology they are able to discriminate between the residual build up of foam on the sensor and the foam created during the process. Thus Charis sensors are able to continue to efficiently monitor foam levels regardless of how fouled the sensor may become. Heads The standard head design used on Charis SureSense sensors is seen in the picture right. It is available in aluminium, stainless steel or heavy duty plastic. Alternatively, if space is limited the sensor can be supplied fitted with a mini aluminium head. The only exception to this head design is the SureSense Laboratory Sensor which is fitted with a Lemo connector. Process Fittings With a wide range of applications our sensors are available with an equally wide range of process fittings. If the level of foam is variable then sensors can be made adjustable, or if the optimum level is known then the sensor can be set at a fixed length. Fittings available for use with SureSense sensors are ½ BSP, DN25, 1ANSI 316 SS pipe flange, 2ANSI 316 SS pipe flange, 1.5 Triclover, 2 Triclover. Mechanical and Body Material 316 Stainless Steel Insulator Material Vitrex Peek 450g Engineering Thermoplastic Termination Heavy duty die-cast alloy industrial termination lead. Ip66. 2-way ceramic block with screw terminals Cable Entry 20mm ISO Conduit entry Cable Screened twisted pair - eg, Belden 8760 Temperature Maximum continuous operating temperature 150 C Peak temperature 170 C Pressure 10 Bars (higher pressure available to special order)

Foam Sensors Making Sense of SureSense sensor part numbers... Given the variety of heads and process fittings available to customise our SureSense sensors the part numbers can become a little confusing. To try to simplify things all SureSense sensors follow a common part numbering scheme so hopefully this graphic may help. All sensors Start with the Prefix FP This figure is normally 0 F P X 0 X / X X / A Probe diameter in mms. Probe length In mms. Head Type 0: Lab sensor head 1: Aluminium head 2: Mini Aluminium head 3: Plastic head 4: Stainless Steel head Process Fitting 1: Adjustable 2: ½BSP 3: DN25 4: 1ANSI flange 5: 2ANSI flange 6: not allocated 7: not allocated 8; 1 /1½Triclover 9: 2 /2½Triclover Using the key above, the sensor to the right is a FP103/12/500 - which is a 500mm long sensor with aluminium head and DN25 fitting.

Process Fittings Example of use of an adjustable fitting Effective length adjustable by position of Sensor in fitting FP101 probe Fitting inserts into DN25 socket Probe inserts into fitting FF25 Fitting 25mm socket welded to vessel top Final Assembly Fixed fittings FP101 Adjustable FP102 ½ BSP fitting FP103 DN25 Ingold fitting FP104 ANSI welded flange FP105 2 ANSI welded flange FP108/15 1 /1½ Triclover fitting FP108/20 2 Triclover fitting

Foam Controllers FCW2 Controller Designed with reliability in mind the FCW2 is an advanced wall mounted foam controller designed to control foam at a fixed level, or to reduce it to a minimum. Our unique IMA Sensing technology ensures the system will operate correctly even if the attached sensor becomes severely fouled. To discriminate between foam and splashing or other spurious triggers the controller has an adjustable response time. A dosing or shot time can be set for the operation of a pump or valve for antifoam addition. Although the FCW2 can be used for stand alone control other control actions such as vacuum valves or gas control can be interfaced. Volt free contacts can be used for point detection and an analogue output for level indication. Power supply 110v, 240v AC., 50Hz, or 24v DC. Indicators Power: illuminates when unit connected to power supply Sense: illuminates when foam is first sensed Activate: illuminates when foam detected continuously for pre-set delay time and stays on until foam collapses Response Time 1,2,4,8,12,16,20,24,28,32,36,40,44,52,60 seconds (set by dil switches) Shot Time Sensitivity 1,2,4,8,12,16,20,24,28,32,36,40,44,52,60 seconds (set by dil switches) 0.35K to 100K ohms impedance (set by dil switches) Fouling Immunity Sensitivity to fouling <1% of sensitivity to foam using Charis sensor Interfaces Volt free c/o contacts rated at 240v AC/30v DC., 2amps. 0-20mA, 4-20mA analogue output IP Rating IP65 wall mounting Dimensions Height (including glands) 225mm, Width 240mm, Depth 115mm Connections Screw terminals. Cable entry via PG11 cable glands (4) FCR2 Controller Basically the FCR2 is a rack mounted version of the FCW2. Designed to fit into a 19 rack the controller is a standard eurocard size and has all the features of the FCW2. Same as for the FCW2 Format 8HP x 3U standard eurocard. Standard 19 rack mounting Dimensions pcb: 100x160mm. Overal; 130x190x40mm including panel and handle Mating connector Harting 0904 232 6823l FTRAN The FTRAN is an advanced Foam Detector designed to be interfaced with an existing process controller or alarm. It can be wall mounted or fit inside an existing cabinet. Same as for the FCW2 except for there being no shot time facility. Dimensions Connections Height 150mm, Width 200mm, Depth 80mm Screw terminals

Foam Control Systems These 2 self contained controllers feature an integral dosing pump and are designed for use with Charis Technology Sensors. FCS2 Benchtop Controller The FCS2 is a bench standing advanced Foam Controller which, when used in conjunction with a Charis Laboratory Sensor forms a compact foam control system for the control of foam in a laboratory process. It includes an integral pump for the automatic addition of a chemical antifoam agent. A delay and shot algorithm is used to give a very reliable control of the foam with the minimum usage of antifoam. Two relays can be connected to external equipment. One operates when foam is detected and the other switches on an off with the pump. The response time is variable to discriminate against splashing and other spurious triggers. Power supply 220-250v AC., 50Hz Pump Watson Marlow 102 pump head, 12rpm, Flow 0.2-19ml/min. Indicators Power: illuminates when unit connected to power supply Sense: illuminates when foam is first sensed Activate: illuminates when foam detected continuously for pre-set delay time and stays on until foam collapses Response Time 1,2,4,8,12,16,20,24,28,32,36,40,44,52,60 seconds (set by dil switches) Shot Time Sensitivity 1,2,4,8,12,16,20,24,28,32,36,40,44,52,60 seconds (set by dil switches) Adjusted by means of a 4 pole switch.35k to 100K ohms impedance Fouling Immunity Sensitivity to fouling <1% of sensitivity to foam using Charis sensor Interfaces Volt free c/o contacts rated at 240v AC/30v DC., 2amps. Relay 1 operates with pump. Relay 2 operates with active indicator. Type Dimensions Connections 28HP x 3U 19 caseframe Width 186mm, Depth 262mm, Height 147mm Power: IEC, Sensor: Lemo, Interface: screw terminals - all mounted in rear panel. FCS200 Control System Designed for industrial applications the FCS200 is an intelligent Foam Control System with integral diaphragm pump. The FCS200 features high reliability and can be operated for long periods without attention. A Charis foam sensor can be placed in a suitable position to detect foam when it occurs. An internal dosing system operates the pump automatically in a shot and delay mode to minimise antifoam usage. In addition the pump speed can be adjusted to suit the requirements of the process and may be switched off or run in manual mode if required. Power Supply 110, 230v AC., 50/60Hz (specify when ordering) Indicators Power: illuminates when unit connected to power supply Sense: illuminates when foam is first sensed Activate: illuminates when pump is actuated automatically Pump Alldos DMI5 diaphragm Flow Rate 0 to 5lt/hour at 5 bars back pressure Sensitivity 35K to 100K ohms impedance Fouling Immunity Sensitivity to fouling <1% of sensitivity to foam using Charis sensor IP Rating IP65 Mounting Wall mounting with brackets Dimensions Height 400mm, Width 300mm, Depth 200mm (enclosure) Connections Screw terminals. Cable entry via Pg135 cable glands x 4.

Foam and level control In some applications it may be necessary to measure foam and give some indication of the level of process liquid as well. It might be that you have a large biodigester with a continual throughput of wastewater. What happens if the exit pipe or filter from the vessel blocks and the wastewater level rises above the foam sensor level? Firstly the sensor assumes the rising wastewater to be foam and starts adding antifoam on a continual basis, thus adding to the problem. To overcome this and other problems where a process involves changing liquid levels, Charis Technology have developed the Foam and Level Control System with software to control foam in the normal way, but also to detect too high a level of liquid and send a control signal to set an alarm or activate part of your process control system. This could take the form of isolating the antifoam pump, or closing the input valve to the biodigester until such times as the blockage or other problem is cleared. This system uses the standard range of SureSense sensors. However, the SureSense Foam and Level Control will not measure liquid and foam together - for that you would need to look at our MultiSense range. FLCW2 Controller Designed with reliability in mind the FLCW2 is an advanced wall mounted foam and level controller designed to control foam at a fixed level or reduce it to a minimum, and give a positive indication if the liquid level in the vessel rises too high. Applications include Biotechnology, Food and Chemical Manufacture and Effluent treatment. The FLCW2 can discriminate between foam and liquid at the sensor by means of the change in density. To discriminate between foam and splashing or other spurious triggers the controller has an adjustable response time. A dosing or shot time can be set for the operation of a pump or valve for antifoam addition. Separate Liquid and Foam switches (volt-free contacts) can be used for point detection and an analogue o/p for level indication. When foam is detected the foam output switches, but when the liquid is detected the foam output is reset and the liquid output switches. Power supply 110v, 240v AC., 50Hz, or 24v DC. Indicators Power: illuminates when unit connected to power supply Sense: illuminates when foam is first sensed Activate: illuminates when foam detected continuously for pre-set delay time and stays on until foam collapses Response Time 1,2,4,8,12,16,20,24,28,32,36,40,44,52,60 seconds (set by dil switches) Shot Time Sensitivity 1,2,4,8,12,16,20,24,28,32,36,40,44,52,60 seconds (set by dil switches) 0.35K to 100K ohms impedance (set by dil switches) Fouling Immunity Sensitivity to fouling <1% of sensitivity to foam using Charis sensor Output Liquid Volt free c/o contacts rated at 240 volts ac / 30 volts dc, 2amps Output Foam Combined Output Volt free c/o contacts rated at 240 volts ac / 30 volts dc, 2amps 0-20mA, 420mA analogue IP Rating IP65 wall mounting Dimensions Height (including glands) 225mm, Width 240mm, Depth 115mm Connections Screw terminals. Cable entry via PG11 cable glands (4) FLCR2 Controller Basically the FLCR2 is a rack mounted version of the FLCW2. Designed to fit into a 19 rack the controller is a standard eurocard size and has all the features of the FCW2. Same as for the FLCW2 Format 8HP x 3U standard eurocard. Standard 19 rack mounting Dimensions pcb: 100x160mm. Overal; 130x190x40mm including panel and handle Mating connector Harting 0904 232 6823l

IMA Sensing technology At last, a foam control system that really works - even when fouled! If you think all foam sensors cease to operate efficiently when they become fouled with residual product then Charis have the answer. Only Charis Technology Foam Control Systems have unique Intelligent Multi Action Sensing Technology ( IMA Sensing technology) to beat even the heaviest fouling. A special guard electrode (blue arrow) disrupts the desensitising effect of the accumulated fouling thus allowing the main foam sensing electrode (red arrow) to ignore the fouling and monitor only the active foam within the process. So no matter how dense or sticky the fouling on the sensor may become the Charis Foam Control System continues to function giving accurate and reliable foam control. For a practical demonstration of IMA Sensing technology at work visit our website at www..uk.com. Registered Trade Mark Charis Technology Ltd Unit J, Altbarn Close, Revenge Road, Chatham, Kent ME5 8UD Tel: +44 (0)1622 751731 Fax: +44 (0)1622 688922 Website: www..uk.com Email: sales@.uk.com