Residential Elevator DESIGN GUIDE. ASME A17.1, Section 5.3. Inline Gear Drive Hydraulic Drive Winding Drum Drive. symmetryelevator.com

Similar documents
Design Guide ASME A18.1

TABLE OF CONTENTS. Contractor Notes 2. Specifications for Symmetry 3-4 Residential Elevator. Typical Hoistway Configurations 5-7

Elvoron CPL. Planning Guide

Home Elevator. Planning Guide

ELVORON HOME ELEVATOR

ELVORON HR DESIGN AND PLANNING GUIDE

Planning Guide. ThyssenKrupp. ThyssenKrupp Access Residential Elevator Division. for Residential Elevators ASME A17.1, Part V, Section 5.

National Reach. Local Service.

Elvoron Home Elevator

Built for every day, designed for any style.

Creating An Accessible World ELVORON CPL.

Home Elevator. Specifically engineered for residential applications

Elite RESIDENTIAL ELEVATOR. AmeriGlide Accessibility Solutions

Planning Guide. Residential Winding Drum Elevators. Series MRL RMR. Built on T Rail

Built for every day, designed for any style.

Planning Guide. ThyssenKrupp. ThyssenKrupp Access. for Residential Elevators ASME A Section 5.3. March 28, 2006

Manufacturer, Installation & Service Of Residential Elevators

Architectural Specifications. Division 14 Elevators Dumbwaiters

Residential Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Concord Dealer)

Eclipse Gearless Residential Elevators OWNER S MANUAL

Residential Elevators

savaria, Eclipse Residential Elevator OWNER'S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer)

SunCoast Elevator Co. Residential elevators can be as unique as your home s interior Ph PAGE 2

A LUXURY STANDARD CREATING A LIFETIME HOME

Built for every day, designed for any style.

luxury & convenience home elevators by

Orion LU/LA Commercial Elevator OWNER S MANUAL

Quality Elevators by Garaventa ELVORON HR. Hydraulic Residential Elevator

Green Elevator: minimal energy consumption required during ascent and no energy necessary for descent

Bruno VPL-3300B Series

Bruno VPL-3300B Series

Infinity & Infinity HD

Group One Roped Hydraulic. Elevators. as well as many other applications

Infinity & Infinity HD

HOME LIFT CATALOGUE LIFTS & COMPONENTS

Reflection. Aluminium Sectional Doors

INSTALLATION INSTRUCTIONS AMBASSADOR DRUM OVERHEAD SERIES 100 DUMBWAITER

Austin. Aluminium Sectional Doors

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT)

INCLINATOR ELEVETTE HOME ELEVATORS INDOOR & OUTDOOR VERTICAL PLATFORM LIFTS RESIDENTIAL & COMMERCIAL DUMBWAITERS

Life. Elevated. National Reach. Local Service. Residential Elevator Catalog

Telecab Planning Guide

Piccolo. Vertical cabin platform lifts

LU/LA Elevators. Value: 1 contact hour (0.1 CEU) by Jay Dickens

DELAWARE ELE TOR

V1504 Vertical Platform Lift OWNER S MANUAL

Creating An Accessible World. genesis SHAFTWAY. Shaftway vertical platform lift for lifting heights up to 14 feet.

MACHINE ROOM-LESS ELEVATOR

Commercial & Residential

Saxton. Steel Sectional Doors

Comfort. Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

Industrial Lifting Equipment

Timber Sectional Doors

DRIVE: 1 hp motor; 1750 rpm, single phase, 120 VAC, 60 Hz, 13.4 Full Load Amps, 1.15 service factor, continuous duty

American Crescent Elevator's Lula Lift

INSTALLATION INSTRUCTIONS FRONT CONTROL ELECTRIC RANGES

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.

Guide for Inspection of Elevators, Escalators, and Moving Walks

ES-125 Inclined Platform Lift OWNER S MANUAL

WORKBOOK/PRICE LIST JULy 2011

Creating An Accessible World GENESIS SHAFTWAY PLANNING GUIDE. Shaftway vertical platform lift for lifting heights up to 14 feet.

Opening Quality Doors Around The World. Installation Instructions Bi-Parting Freight Doors - Q Style (Power and Manual)

Guide for Inspection of Elevators, Escalators, and Moving Walks

Prolift SCL/Prolift HD

TM MANUFACTURERS

MONOGRAM 36" BUILT-IN SIDE-BY-SIDE REFRIGERATOR

Creating An Accessible World. genesis. Enclosure or shaftway vertical platform lift for lifting heights up to 14 feet.

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

Bruno Vertical Platform Lift

C L FOR MOUNTING WNK CHECKED BY

Raising Standards in Accessibility

MONOGRAM 42" BUILT-IN SIDE-BY-SIDE REFRIGERATOR

SteelForm S-24C SECTIONAL OVERHEAD DOORS

Worm Gear Hand Winches Up to 4000 lb capacity

OMEGA PLANNING GUIDE. Curved Inclined Platform Lift. Applicable Codes: ASME A17.1 ASME A18.1 CAN/CSA B355 CAN/CSA B m Part No.

Midwest Electric Products. AC Disconnects

Type 4 Panel Enclosures

Your Global Source for Today s Most Popular Solenoid Valves

DOOR STOPS & HOLDERS DOOR TRIM & ACCESSORIES DOME DOOR STOPS CONVEX & CONCAVE WALL STOPS WALL MOUNTED DOOR STOPS ORDERING EXAMPLE: -26D C200 SERIES

Installation Information 2009 Model 300 Dumbwaiter

MAINTENANCE EVALUATION CHECKLIST ELECTRIC ELEVATORS

GENESIS ENCLOSURE PLANNING GUIDE. Vertical Platform Lift and Factory Enclosure for lifting heights up to 14 feet.

Stannah Midilift SL/GL

INCLINATOR ELEVETTE MACHINE ROOMLESS (MRL) OVERHEAD CABLE DRUM. Planning Guide. MACHINE ROOMLESS (MRL) OVERHEAD CABLE DRUM 1000 lb.

Derailment Detector Assembly

ThermaSeal TM220 SECTIONAL OVERHEAD DOORS

Inteli-Lift GEN II DUMBWAITER

Monogram 36" Built-In Side-by-Side Refrigerator

SECTION [ ] SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Installation and Service Manual

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C

VESTNER Advance World Easy-to-plan and cost-efficient. Plus for your construction project.

DONKEY-2 Specifications

RESIDENTIAL ELEVATORS

Creating An Accessible World XPRESS II. Inclined platform lift for straight stairways.

Creating An Accessible World. Vertical Platform Lift and Enclosure for lifting heights up to 14 feet.

GENESIS OPAL PLANNING GUIDE. Unenclosed Platform Lift for commercial applications of up to 5 feet lifting height. Creating An Accessible World


BODY COMPONENTS SECTION H. Fender Backs. Metal Slat. Fender Brackets. Roof Vent. Ramps & Rails. Replacement Dome. Ramp Assist Spring

Transcription:

Residential Elevator ESIGN GUIE SME 7., Section 5.3 Inline Gear rive Hydraulic rive Winding rum rive symmetryelevator.com 877.375.428

Table of ontents bout Symmetry Elevating Solutions... 2 Residential Elevator Safety Notice... 3 Residential Elevator rive Systems... 4 Equipment for Symmetry Residential Elevators... 5 Elevator ar s & Gates... 6 Two and Three Speed utomatic Elevator ar s... 7 Typical Hoistway onstruction... 8-2 Hoistway Typical Rail acking onstruction... 3 Hoistway onstruction Outline... 4 Inline Gear rive Remote ontroller... 5 Inline Gear rive MRL ontroller & ccess Hatch etail... 6 Hydraulic rive Machine Rooms... 7 Winding rum rive Machine Room... 8 Flush & Frame... 9 bout Symmetry Elevating Solutions Symmetry is a beautifully crafted, expertly engineered accessibility-related product line proudly made in the U.S.. at the ella Elevator LL manufacturing plant. Promoted and sold by our exclusive nationwide network of carefully selected Symmetry partners and associates, Symmetry offers residential elevators, vertical platform lifts and Limited Use/Limited pplication (LU/L) elevators. Strictly following national code guidelines and adhering to local jurisdiction requirements and variances, Symmetry products are and SME compliant and manufactured to meet the end users specific needs. Symmetry Elevating Solutions representatives possess a wealth of knowledge and experience and are committed to excellence for the life of the product before, during and after project completion. With dealer locations spanning North merica, we are equipped to meet the accessibility needs of a wide spectrum of clients, from home and business owners, to municipalities, school and other governmental entities. Please note that this guide is for planning purposes only, applies exclusively to national code, and should not be used for construction. Prior to construction, please contact your local Symmetry Elevating Solutions representative and request a job-specific set of elevator plans to ensure that you obtain the accurate dimensions and requirements for your project. Your representative will also assist you to make sure that your project plans will comply with the applicable state and local codes and the building authority. 2 symmetryelevator.com 877.375.428

Residential Elevator Safety as mandated by national code Securing the space between the hoistway door and the car gate/door epending on the version of code that is enforced in your local jurisdiction, the hoistway door and car gate/ door space requirements differ. If your jurisdiction enforces SME 7. (year 203 & prior) Elevator and Escalator Safety ode, the rule was referred to as the 3" x 5" rule and is depicted in the image below, on the left. In 206, the SME 7. code was revised, with the new ¾" x 4" rule being adopted. The requirements for 7. (year 206 & future) are depicted in the image below, on the right. This rule was amended after it was determined that utilizing a standard residential hoistway door, installed under SME 7. (year 203 & prior), allows a space between the hoistway door and car gate/door large enough for a child to hide, thus subjecting the child to a potentially unsafe scenario, which could result in serious injury if said space is not protected by some other means. NOTE: Symmetry residential elevators have added security features that protect this space. ll Symmetry residential elevators are provided with a standard, enhanced gate switch bypass monitor that continuously monitors the elevator control system to detect a scenario where someone may enter the space between the hoistway and the car, without ever entering the car. The enhanced gate switch bypass monitor will keep the elevator from leaving the landing should it detect the aforementioned event. dditionally, should you live in a jurisdiction that still enforces the SME 7. (year 203 & prior) code, your elevator will also be equipped with a light curtain that projects a crisscross pattern of 92 beams to keep the elevator from leaving the landing should an obstruction be detected. Your safety is our number one priority. Thus, rest assured that regardless of the version of Elevator and Escalator Safety ode that is enforced in your jurisdiction, your Symmetry residential elevator safely protects the space between the hoistway door and car gate/door. Please consult your local Symmetry Elevation Solutions representative regarding door and hoistway safety code recommendations. Hoistway s & ar Gate/ /Gate Requirements SME 7. 203 & Prior Hoistway s & ar ar Gate/ /Gate Requirements SME 7. 206 & Future Light urtain Hoistway ccordion ar 3" maximum Maximum as s measured Measured from From the The inside Inside face Face of the Hoistway Of The Hoistway to the car To edge ar Edge of the Of Hoistway The Hoistway Sill SIll 5" maximum Maximum as s measured Measured from From the The inside Inside face Face of the Of Hoistway The Hoistway to the face To The of the Face ar Of Gate/ The ar /Gate. 2 ½" ¼" - 4" Running running clearance learance as s measured Measured from The ar the ar Sill Sill to To the The Hoistway Sill Sill Hoistway ccordion ar (Locking Mechanical Hinge) ¼" 4" Maximum maximum With with n an ccordion ar ¾" 3 4" Maximum maximum With with other Other ar ar Gate/ /Gates as measured from s Measured the inside From face The of the Inside Hoistway Face Of The to car edge of the Hoistway Hoistway SillTo ar Edge Of The Hoistway SIll 4" maximum Maximum as s measured Measured from From the The outside Inside face Face of Of the The Hoistway to To the The outside Outside of the Of The ar ar (must (Must reject Reject a 4" 4" ball) all) 2-4" Running learance s Measured The ar Sill ½" ¼" To The Hoistway running clearance Sill as measured from the ar Sill to the Hoistway Sill symmetryelevator.com 877.375.428 3

Elevator rive Systems Overhead Sheave rive Unit 2 hp gearmotor with brake Modular Rail Structure Ram Header ounterweight ssembly Two ⅜" 7 x 9 Galvanized ircraft ables 4400 lbs. breaking strength ar Frame Roller hain Modular Rail Structure ar Frame ar Frame Hydraulic ylinder Modular Rail Structure Two ⅜" 7 x 9 Galvanized ircraft ables 4400 lbs. breaking strength Window Sheave Winding rum Machine Pedestal Post General Inline Gear rive System Overhead minimum of 8'0" (96 inches) with remote controller; mimimum of 9'0" with controller in hoistway with a 7'0" interior car height Mechanical Equipment 208/230 V, 60HZ, 20 amp, singlephase power supply for motor controller Two #60 roller chains Inverter-controlled variable speed Inline Gear rive unit with counterweight and 2 hp motor Manual lowering device Safety Features Slack chain safety device Two upper and one lower final limit Machine stop switch Hydraulic rive System General Overhead minimum of 7'0" (94 inches) with a 7'0" interior car height Mechanical Equipment 208/230 V, 60HZ, 30 amp, singlephase power supply for motor controller Two ⅜" 7 x 9 galvanized aircraft cable (4400 lbs. breaking strength) with wedge rope shackles 80mm diameter piston/02 mm diameter cylinder including ¾" reducer brushing 3 hp submersed motor with 2-speed valve assembly Manual down valve for emergency lowering Safety Features Slack rope safety device Line rupture valve Winding rum rive System General Overhead minimum of 7'0" (94 inches) with a 7'0" interior car height Mechanical Equipment 208/230 V, 60HZ, 30 amp, singlephase power supply for motor controller Two ⅜ 7 x 9 galvanized aircraft cable (4400 lbs. breaking strength) Inverter-controlled variable speed winding drum drive unit and 3 hp motor Manual lowering device Safety Features Slack rope safety device Two upper and one lower final limits 4 symmetryelevator.com 877.375.428

ommon Specifications for residential elevator equipment General Travel: maximum of 50'0" (minimum 2 inches between stops) Speed: 40 fpm Rated capacity:,000 lbs. Pit depth: 6" minimum (8 inches preferred) Two stops Single opening Three-year limited parts warranty Mechanical Equipment Modular 6 lb. T-rail structure ar frame assembly Power supply for motor controller (See each drive for specifics.) 20 V, 60HZ, 5 amp single-phase power supply ode-compliant electrical disconnects included* Safety Features Motor controller supply disconnects (located in controller) ar light supply disconnects (located in controller) Pit stop switch ar-top stop switch In-car emergency stop switch and alarm Safety switch for car gate(s) attery backup emergency car lights and alarm Electromechanical hoistway door interlocks (doors by others) Light curtain monitoring the car entrance ontrols Programmable Logic ontroller (PL) Non-selective collective automatic operation S.M..R.T. system (Self-Monitoring lert Response Technology) * ar Operating Panel (OP) with LE floor position indicator Recessed phone box (phone jack included) Hall stations with call button and LE floor position indicator utomatic car lighting Single floor designated car homing Uninterruptible Power Supply (UPS) for car lowering and automatic car gate/door operation (if provided) in the event of a power failure* ar Features ar size up to 5 square feet 7'0" interior car height irch, Oak or Maple flat veneer interior walls with flat ceiling* Matching wood handrail Matching wood car sill Unfinished plywood floor with sill set for ¾ (flooring by others) Two energy-saving recessed LE lights with black trim rings 7'0" vinyl laminate accordion gate (Light Oak, ark Oak, irch, White, halk or ntique White) Optional Features Up to six stops Single automatic push-button operation ustom car size up to 8 square feet ** ustom car heights Shaker or Recessed panel car with flat ceiling Shaker, Recessed or Raised panel car with matching ceiling Four recessed LE lights with lack, Polished rass, rushed Nickel or ronze trim rings Factory-finished car Polished Stainless Steel, Polished or rushed rass, lack Vintage ronze and Oil-Rubbed rass fixtures (including OPs, phone boxes, hall calls and handrails) OP with integrated keypad phone ustom wood interiors ustom factory finishes (ntiqued, istressed and rackle) * "Green" material alternatives and finishes for car interiors * ¾" finished or unfinished installed hardwood car flooring Factory flooring insert for ¼" flooring by others uffer springs (requires minimum of 0 inch pit depth) Key switch for OP and/or hall stations 750-lb. car capacity ar Gate/ Options Symmetry Safety 3-Panel car door Two and three speed car door or car and landing doors Wrap around car door Enterprise collapsible gate Hardwood veneer accordion gate lear acrylic panel accordion gate utomatic car gate/door operator (not available on the Enterprise collapsible gate) NOTE: ccordion gates will have ronze hardware except on White, halk or ntique White gates. crylic gates will have lear hardware when Stainless Steel or lack fixtures are provided. * enotes exclusive features ** May require approval from the local authority having jurisdiction epends upon the package ordered vailability depends on the code year Standard finish is brushed stainless steel, but multiple finishes available. symmetryelevator.com 877.375.428 5

Elevator ar s & Gates Symmetry Safety 3-Panel ar Enterprise ollapsible Gate ccordion Gate Our exclusive Symmetry Safety 3-Panel is one of the safest residential elevator car doors on the market. Panels shown in lack with vision panel, rushed Stainless Steel and Vintage ronze. STNR FETURES - Manual ar Operation the trailing panel of the car door measures at 2" from edge of the car sill and is restricted to a maximum hoistway door setback of ¾" under the 3" x 5" rule; designed to fit within requirements of the new ¾" x 4" rule, with maximum running clearance and maximum hoistway door setback of ¾" - Height of Opening 7'0" - ar Opening 33" clear opening (fits in a "typical" hoistway with a 36"-wide car) OPTIONS - Power ar Operation the leading panel of the car doors measures at ½" from the edge of the car sill and is restricted to a maximum hoistway door setback of 3" under the 3" x 5" rule; designed to fit within the requirements of the new ¾" x 4" rule with the maximum hoistway door setback of ¾" - Height of Opening 7'"; custom heights available - ar Opening 36" clear opening (fits in a "typical" hoistway with a 40"-wide car) - Light urtain optional if installed under the ¾" x 4" rule; standard as secondary protective device if unit installed under the 3" x 5" rule - Vision Panels available with clear or bronze Plexiglas The Enterprise ollapsible Gate is always designed and manufactured to comply with current codes. Shown in Vintage ronze. STNR FETURES - Nylon Quiet Glide wheels for smooth operation when opening and closing gate - Low Profile Handles - Rejects a ball 3 in diameter - Every third vertical member guided at the top - Every vertical member guided at the bottom OPTIONS - Light urtain optional if installed under the ¾" x 4" rule; standard as a secondary protective device if installed under the 3" x 5" rule - vailable in solid brass (brushed or polished), stainless steel (brushed or polished) or powdercoated steel - Selection of attractive standard and premium finishes available; custom colors also available upon request - 75 Option is available to meet the deflection requirements of SME 7. 206 NOTE: rass is not available with the 75 option. The ccordion Gate is one of our most popular gate choices. Shown in ntique White with Vision Panels. STNR FETURES - Laminate panels in Light Oak, ark Oak, irch, White, ntique White or halk - Vinyl hinging (SME 7. 203 or prior) - Height of Opening from 6'8" up to 7'" OPTIONS - dditional Panel Options Laminate panels in herry, Walnut or lack Unfinished or finished matching hardwood lear or ronze/smoke crylic Solid or Perforated luminum - Light urtain optional if installed under the ¾" x 4" rule; standard as a secondary protective device if installed under the 3" x 5" rule - Mechanical hinging (SME 7. 203 or prior) - Locking mechanical hinging is available to meet the deflection requirements of SME 7. 206. (This allows for ¼" maximum hoistway door setback.) - Vision Panels available with lear or ronze/ Smoke crylic 6 symmetryelevator.com 877.375.428

Two & Three Speed utomatic Elevator ar s ar doors only or car and landing doors Two Speed ar and Landing in rushed Stainless Steel utomatic commercial-style doors optimize ease of use for passengers. ar door only or car and landing door packages available. STNR FETURES - Power-operated - lear Openings 3½", 35½" or 36" - lear Heights 78¾", 84⅝" or 94½" - Panels come standard in eige. - Light urtain Three Speed ar in rushed Stainless Steel vailable Finishes ustom colors are available upon request. OVERHE REQUIREMENTS - Two Speed s ar and landing doors 98" ar door only 97" rushed Stainless Steel eige (standard) lack White Vintage ronze - Three Speed s ar and landing doors/car door only 0" OPTIONS - Framed Glass Panels available with clear safety glass; not currently offered on hoistway doors; standard finish for panels is lack - vailable in rushed Stainless or powder-coated steel in eige, lack, White, Vintage ronze, Zinc Rich Primer, Goldsmith, in Silver, ast ronze and Ivory Zinc Rich Primer Goldsmith in Silver ast ronze Ivory ustom colors upon request symmetryelevator.com 877.375.428 7

Typical Hoistway Options ll hoistway dimensions reference interior dimensions finished wall to finished wall. Single Opening Rail Left, Right-Hand (shown) Rail Right, Left-Hand (opposite) RIL EPTH ar Gate/ ar Size EPTH Width epth Rail RIL lear Opening OOR STRUTURE ccordion or ollapsible (2) Symmetry Safety 3-Panel OOR STRUTURE 36x48 50½" 54¼" 27½" 28¾" 33½" 36x60 50½" 66¼" 33½" 28¾" 33½" 40x54 54½" 60¼" 32" 32¾" 33½" (3) 36x48 52" 55" 3" 30¼" 33" 36x60 52" 67" 33½" 30¼" 33" 40x54 54½" 6" 3" 32¾" 33" (3) OOR GTE ORION OR OLLPSILE SYMMETRY SFETY 3 PNEL OOR EPTH SINGLE OPENING RIL LEFT, RIGHT HN OOR (SHOWN) RIL RIGHT, LEFT HN OOR (OPPOSITE) R SIZE EPTH 36 x 48 36 x 60 40 x 54 36 x 48 36 x 60 40 x 54 50 /2" 54 /4" 27 /2" 28 3/4" 33 /2" 50 /2" 66 /4" 33 /2" 28 3/4" 33 /2" 54 /2" 60 /4" 32" 32 3/4" 33 /2" 52" 55" 3" 30 /4" 33" EPTH 52" 67" RIL 33 /2" 30 /4" 33" 54 /2" 6" 3" 32 3/4" 33" RIL STRUTURE STRUTURE RIL OOR OOR LER OPENING GTE ORION OR OLLPSILE ar Gate/ SYMMETRY SFETY 3 PNEL ccordion or ollapsible (2) Symmetry Safety 3-Panel 36 x 48 50 /2" Opposite 54" Opening 27" 28 3/4" 33 /2" Rail 36 Right, x 60 50 Left-Hand /2" 66", 33" Right-Hand 28 3/4" 33 /2" Rail 40 Left, x 54 Right-Hand 54 /2" 60", 30" Left-Hand 32 3/4" 33 /2" EPTH OPPOSITE OPENING RIL LEFT, RIGHT HN OOR, LEFT HN OOR RIL RIGHT, LEFT HN OOR, RIGHT HN OOR R SIZE EPTH 36 x 54 ar 36 x 60 Size 40 x 54 52" 6 3/4" 3" 30 /4" Width epth Rail 33" 52" 67 3/4" 34" 30 /4" 33" 54 /2" 6 3/4" 3" 32 3/4" 33" lear Opening 36x48 50½" 54" 27" 28¾" 33½" 36x60 RIL 50½" 66" 33" 28¾" 33½" 40x54 54½" 60" 30" 32¾" 33½" (3) STRUTURE RIL OOR LER OPENING 36x54 52" 6¾" 3" 30¼" 33" 36x60 52" 67¾" 34" 30¼" 33" 40x54 54½" 6¾" 3" 32¾" 33" (3) GTE 8 ORION OR OLLPSILE () Inline Gear rive motor extends into the access hatch OOR (2) ollapsible gates will have a clear opening approximately " less than shown (3) 36" clear opening available door centerlines may change SINGLE OPENING RIL FRONT, LEFT HN OOR (SHOWN) centerlines RIL FRONT, apply RIGHT HN to 3'0" OOR doors, (OPPOSITE) except where otherwise noted. R SIZE EPTH RIL OOR LER OPENING 36 x 48 48" 62 /4" 23 /2" 23 /4" 32 /4" 36 x 60 48" 74 /4" 23 /2" 23 /4" 40 x 54 48" 68 /4" 24" 2 3/4" symmetryelevator.com OR 877.375.428 32 /4" 33 /2" GTE ORION OLLPSILE OOR SINGLE OPENING RIL FRONT, LEFT HN OOR (SHOWN) RIL FRONT, RIGHT HN OOR (OPPOSITE) R SIZE EPTH RIL OOR LER OPENING 48 x 36 55" 50 /4" 27 /2" 2 3/4" 33 /2" 60 x 36 67" 50 /4" 33 /2" 2 3/4" 33 /2" 54 x 40 6" 54 /4" 30 /2" 2 3/4" 33 /2"

Typical Hoistway Options ll hoistway dimensions reference interior dimensions finished wall to finished wall. EPTH RIL GTE OOR EPTH ORION OR OLLPSILE RIL STRUTURE OPPOSITE OPENING RIL LEFT, RIGHT HN OOR, LEFT HN OOR RIL RIGHT, LEFT HN OOR, RIGHT HN OOR RIL OOR LER R SIZE EPTH OPENING 36 x 48 50 /2" 54" 27" 28 3/4" 33 /2" 36 x 60 STRUTURE 50 /2" 66" 33" 28 3/4" 33 /2" 40 x 54OOR 54 /2" 60" 30" 32 3/4" 33 /2" OOR ar Gate/ ccordion or ollapsible (2) Symmetry 3-Panel Safety Single Opening Rail Front, Left-Hand (shown) Rail Front, Right-Hand (opposite) ar Size Width epth Rail lear Opening 36x48 48" 62¼" 23½" () 23¼" 32¼" 36x60 48" 74¼" 23½" () 23¼" 32¼" 40x54 48" 68¼" 24" () 2¾" 33½" 36x48 52¼" 63⅛" 22" () 2¾" 33" 36x60 52¼" 75⅛" 22" () 2¾" 33" 40x54 54½" 69⅛" 24½" 2¾" 33" SYMMETRY SFETY 3 PNEL EPTH 36 x 54 36 x 60 40 x 54 52" 6 3/4" 3" 30 /4" 33" 52" 67 3/4" 34" 30 /4" 33" 54 /2" 6 3/4" 3" 32 3/4" 33" RIL STRUTURE ar Gate/ ccordion or ollapsible (2) Symmetry 3-Panel Safety Single Opening Rail Front, Left-Hand (shown) Rail Front, Right-Hand (opposite) ar Size Width epth Rail lear Opening 48x36 55" 50¼" 27½" 2¾" 33½" (3) 60x36 67" 50¼" 33½" 2¾" 33½" (3) 54x40 6" 54¼" 30½" 2¾" 33½" (3) 48x36 55" 5⅛" 27½" 2¾" 33" 60x36 67" 5⅛" 33½" 2¾" 33" (3) 54x40 6" 55⅛" 30½" 2¾" 33" (3) OOR SINGLE OPENING RIL FRONT, LEFT HN OOR (SHOWN) () Inline RIL Gear FRONT, rive RIGHT motor HN extends OOR (OPPOSITE) into the access hatch RIL OOR LER GTE (2) ollapsible R SIZE gates will EPTH have a clear opening approximately " less than shown OPENING (3) 36" clear opening available door centerlines may change ORION 48 x 36 55" 50 /4" 27 /2" 2 3/4" 33 /2" OR centerlines apply to 3'0" doors, except where otherwise noted. 60 x 36 67" 50 /4" 33 /2" 2 3/4" 33 /2" OLLPSILE 54 x 40 6" 54 /4" 30 /2" 2 3/4" 33 /2" SYMMETRY SFETY 3 PNEL 48 x 36 60 x 36 55" 67" 5 /8" 5 /8" 27 /2" 2 3/4" 33" symmetryelevator.com 877.375.428 9 33 /2" 2 3/4" 33"

Typical Hoistway Options ll hoistway dimensions reference interior dimensions finished wall to finished wall. RIL EPTH STRUTURE OOR "" OOR "" OOR "" RIL EPTH STRUTURE R SIZE EPTH RIL OOR LER OOR LER OPENING OPENING 6 x 48 50 /4" 54 3/4" OOR 3" "" 24 /4" 3" 27" 33 /2" 6 x 60 50 /4" 66 3/4" 33 /2" 24 /4" 3" 39" 33 /2" ar Gate/ ccordion or ollapsible (2) 90º OPENING N OOR, LEFT HN OOR OR RIL FRONT, LEFT HN OOR, RIGHT HN OOR (SHOWN) OOR, RIGHT HN OOR OR RIL FRONT, RIGHT HN OOR, LEFT HN OOR (OPPOSITE) Symmetry Safety 3-Panel 90 Opening Rail Left, Right-Hand, Left-Hand or Rail Front, Left-Hand Right-Hand (shown) Rail Right, Left-Hand, Right-Hand or Rail Front, Right-Hand, Left-Hand (opposite) ar Size Width epth Rail lear Opening lear Opening 36x48 50¼" 54¾" 3" 24¼" 3" 27" 33½" 36x60 50¼" 66¾" 33½" 24¼" 3" 39" 33½" (3) 40x54 54¼" 60¾" 3" 28¼" 33½" 33" 33½" (3) 40x48 55⅛" 55⅝" 3" 30¾" 33" 25⅛" 33" 40x54 55⅛" 6⅝" 3" 30¾" 33" 3⅛" 33" (3) 0 x 54 0 x 48 0 x 54 54 /4" 60 3/4" 3" 28 /4" 33 /2" 33" 33 /2" 55 /8" 55 5/8" 3" 30 3/4" 33" 25 /8" 33" 55 /8" 6 5/8" 3" 30 3/4" 33" 3 /8" 33" SINGLE OPENING N OOR, LEFT HN OOR OR RIL FRONT, LEFT HN OOR, RIGHT HN OOR (SHOWN) OOR, RIGHT HN OOR OR RIL FRONT, RIGHT HN OOR, LEFT HN OOR (OPPOSITE) RIL OOR LER OOR LER R SIZE () Inline EPTH Gear rive motor extends OPENING into the access OPENING hatch 6 x 48 50 /4" 54 3/4" 27 /2" 29 /4" 28 /2" 33" 33 /2" 6 x 60 0 x 54 4 x 48 EPTH STRUTURE RIL OOR "" 50 /4" 66 3/4" 33 /2" 29 /4" 28 /2" 45" 33 /2" 54 /4" 60 3/4" 30 /2" 29 /4" 32 /2" 39" 33 /2" 59 /8" 55 5/8" 28" 29 /4" 33" 33 7/8" 33" OOR "" ar Gate/ ccordion or ollapsible (2) Symmetry Safety 3-Panel ar Size (2) ollapsible gates will have a clear opening approximately " less than shown (3) 36" clear opening available door centerlines may change centerlines apply to 3'0" doors, except where otherwise noted. 90 Opening Rail Right, Right-Hand, Left-Hand or Rail Front, Left-Hand, Right-Hand (shown) Rail Left, Left-Hand, Right-Hand or Rail Front, Right-Hand, Left-Hand (opposite) Width epth Rail lear Opening lear Opening 36x48 50¼" 54¾" 27½" 29¼" 28½" 33" 33½" 36x60 50¼" 66¾" 33½" 29¼" 28½" 45" 33½" (3) 40x54 54¼" 60¾" 30½" 29¼" 32½" 39" 33½" (3) 44x48 59⅛" 55⅝" 28" 29¼" 33" 33⅞" 33" 44x54 59⅛" 6⅝" 3" 29¼" 33" 39⅞" 33" (3) 4 x 54 59 /8" 6 5/8" 3" 29 /4" 33" 39 7/8" 33" 0 symmetryelevator.com 877.375.428

Typical Hoistway Options ll hoistway dimensions reference interior dimensions finished wall to finished wall. OOR OOR GTE 2 SPEE R OORS (SHOWN) 3 SPEE R OORS OOR RIL 40 x 54 RIL 53 EPTH /2" 70 /4" 35" 3 3/4" 35 /2" 54 /2" 64 /4" 32" 32 3/4" 35 /2" STRUTURE EPTH STRUTURE SINGLE OPENING RIL LEFT, RIGHT HN OOR (SHOWN) RIL RIGHT, LEFT HN OOR (OPPOSITE) R SIZE EPTH 44 x 48 44 x 54 36 x 48 36 x 60 38 x 48 38 x 60 RIL OOR OOR LER OPENING 59" 57 /2" 3" 37 /4" 35 /2" 59" 63 /2" 32" 37 /4" 35 /2" 50 /2" 58 /4" 3 /2" 30 3/4" 3 /2" 50 /2" 70 /4" 35" 30 3/4" 3 /2" 53 /2" 58 /4" 3 /2" 3 3/4" 35 /2" RIL EPTH STRUTURE ar Gate/ Two Speed ar s (shown) OOR Three Speed ar s ar Gate/ Two Speed ar s (shown) GTE 2 SPEE R OORS (SHOWN) Three Speed ar s Single Opening Rail Left, Right-Hand (shown) Rail Right, Left-Hand (opposite) Opposite Opening 44 x 54 59" 67 /2" 34" 37 /4" 35 /2" Rail Left, Right-Hand, Left-Hand 36 x 48 50 /2" 63" 32" 30 3/4" 3 /2" Rail Right, Left-Hand, Right-Hand 3 SPEE R OORS OOR ar Size ar Size Width EPTH RIL STRUTURE OPPOSITE OPENING RIL LEFT, RIGHT HN OOR, LEFT HN OOR RIL RIGHT, LEFT HN OOR, RIGHT HN OOR R SIZE EPTH 44 x 48 36 x 60 38 x 48 38 x 60 40 x 54 RIL OOR lear Opening 44x48 59" 6½" 3" 37¼" 35½" 44x54 59" EPTH 67½" 34" 37¼" 35½" 36x48 50½" 63" 32" 30¾" 3½" (4) STRUTURE 36x60 50½" 75" 38" 30¾" 3½" (4) 38x48 53½" 63" 32" 3¾" 35½" 38x60 53½" 75" 38" 3¾" 35½" 40x54 54½" 69" 35" 32¾" 35½" OOR 59" 6 /2" 3" 37 /4" 35 /2" LER OPENING 50 /2" 75" 38" 30 3/4" 3 /2" 53 /2" 63" 32" 3 Width epth Rail 3/4" 35 /2" 53 /2" 75" 38" 3 3/4" 35 /2" 54 /2" 69" 35" 32 3/4" 35 /2" RIL epth Rail OOR lear Opening 44x48 59" 57½" 3" 37¼" 35½" 44x54 59" 63½" 32" 37¼" 35½" 36x48 50½" 58¼" 3½" 30¾" 3½" (4) 36x60 50½" 70¼" 35" 30¾" 3½" (4) 38x48 53½" 58¼" 3½" 3¾" 35½" 38x60 53½" 70¼" 35" 3¾" 35½" 40x54 54½" 64¼" 32" 32¾" 35½" (4) 2'8" doors GTE 2 SPEE R OORS (SHOWN) 3 SPEE R OORS SINGLE OPENING RIL LEFT, RIGHT HN OOR (SHOWN) RIL RIGHT, LEFT HN OOR (OPPOSITE) centerlines apply to 3'0" doors, except where otherwise noted. R SIZE EPTH 44 x 48 44 x 54 36 x 48 36 x 60 38 x 48 RIL OOR LER OPENING 62" 62" 35 /2" 37 3/4" 35 /2" 62" 68" 37" 37 3/4" 35 /2" 36 x 48 52 3/4" 72 3/8" 36 /2" 30 /2" 3 /2" symmetryelevator.com 877.375.428 52 3/4" 63" 36 /2" 30 /2" 3 /2" 52 3/4" 75" 42 /2" 30 /2" 3 /2" 55 3/4" 63" 36 /2" 3 /2" 35 /2" GTE 2 SPEE R OORS (SHOWN) 3 SPEE R OORS OPPOSITE OPENING RIL LEFT, RIGHT HN OOR, LEFT HN OOR RIL RIGHT, LEFT HN OOR, RIGHT HN OOR R SIZE EPTH 44 x 48 44 x 54 36 x 60 38 x 48 RIL OOR LER OPENING 62" 70 /2" 35 /2" 37 3/4" 35 /2" 62" 76 /2" 38 /2" 37 3/4" 35 /2" 52 3/4" 84 3/8" 42 /2" 30 /2" 3 /2" 55 3/4 " 72 3/8" 36 /2" 3 /2" 35 /2"

Typical Hoistway Options ll hoistway dimensions reference interior dimensions finished wall to finished wall. OOR OOR GTE 2 SPEE R OORS (SHOWN) RIL EPTH RIL STRUTURE EPTH STRUTURE R SIZE RIL OOR LER EPTH SINGLE OPENING OPENING 44 x 48 59" 6 /2" 3" 37 /4" 35 /2" 44 x 54 59" 67 /2" 34" 37 /4" 35 /2" 36 x 48 50 /2" 63" 32" 30 3/4" 3 /2" OPPOSITE OPENING RIL LEFT, RIGHT HN OOR, LEFT HN OOR RIL RIGHT, LEFT HN OOR, RIGHT HN OOR OOR ar Gate/ Two Speed ar s (shown) Three Speed ar s Single Opening Rail Left, Right-Hand (shown) Rail Right, Left-Hand (opposite) ar Size Width epth Rail lear Opening 44x48 62" 62" 35½" 37¾" 35½" 44x54 62" 68" 37" 37¾" 35½" 36x48 52¾" 63" 36½" 30½" 3½" (4) 36x60 52¾" 75" 42½" 30½" 3½" (4) 38x48 55¾" 63" 36½" 3½" 35½" 38x60 55¾" 75" 42" 3½" 35½" 40x54 56¾" 69" 39½" 32½" 35½" 3 SPEE R OORS OOR 2 GTE 2 SPEE R OORS (SHOWN) 36 x 60 38 x 48 38 x 60 40 x 54 (4) 2'8" doors 3 SPEE R OORS 50 /2" 75" 38" 30 3/4" 3 /2" 53 /2" 63" 32" 3 3/4" 35 /2" 53 /2" 75" 38" 3 3/4" 35 /2" 54 /2" 69" 35" 32 3/4" 35 /2" RIL EPTH STRUTURE R SIZE EPTH RIL OOR OOR LER OPENING 44 x 48 62" 70 /2" 35 /2" 37 3/4" 35 /2" 44 x 54 62" 76 /2" 38 /2" 37 3/4" 35 /2" 36 x 48 52 3/4" 72 3/8" 36 /2" 30 /2" 3 /2" 36 x 60 52 3/4" 84 3/8" 42 /2" 30 /2" 3 /2" 38 x 48 55 3/4 " 72 3/8" 36 /2" 3 /2" 35 /2" 38 x 60 55 3/4" 84 38" 42 /2" 3 /2" 35 /2" 40 x 54 56 3/4" 78 3/8" 39 /2" 32 /2" 35 /2" OPPOSITE OPENING RIL LEFT, RIGHT HN OOR, LEFT HN OOR RIL RIGHT, LEFT HN OOR, RIGHT HN OOR ar Gate/ Two Speed ar s (shown) Three Speed ar s centerlines apply to 3'0" doors, except where otherwise noted. Single Opening Rail Left, Right-Hand, Left-Hand (shown) Rail Right, Left-Hand, Right-Hand (opposite) ar Size Width epth symmetryelevator.com 877.375.428 Rail lear Opening 44x48 62" 70½" 35½" 37¾" 35½" 44x54 62" 76½" 38½" 37¾" 35½" 36x48 52¾" 72⅜" 36½" 30½" 3½" 36x60 52¾" 84⅜" 42½" 30½" 3½" 38x48 55¾" 72⅜" 36½" 3½" 35½" 38x60 55¾" 84⅜" 42½" 3½" 35½" 40x54 56¾" 78⅜" 39½" 3½" 35½"

Hoistway Typical Rail acking onstruction Each backing member is constructed of two 2 x 0s with ½" plywood between and two 2 x 4s on each end; laminated using Typical wood glue and Rail #8 acking x 2¾" screws onstrucion (minimum). Each backing member constructed of two 2 x 0s with ½" plywood between and two 2 x 4s on each end laminated using wood glue and #8 x 2¾" screws minimum. Finsihed Finished Flooring Overhead (FINISHE FLOOR TO FINISHE EILING) Each backing member constructed of (2) 2x0's with 2" plywood between Please note and (2) that 2x4's Winding on each rum end laminated rives with using greater wood glue than and 30'0" of travel require #8 x 2-3/4" x 2s screws in lieu minimum. of the 2 x 0s, and the centerline spacing increases from 0 inches to 2 inches. Please note that Winding rum rives with greater than 30' of travel require 2x2's in lieu of the 2x0's and the centerline Installing ½" plywood spacing increases behind from the 0" drywall to 2". will improve the sound-deadening Installing 2"plywood behind and strengthen the drywall the will hoistway. improve the sound deadening and strengthen the hoistway. 0" 0" rywall flush to Pit Wall. Finsihed Finished Flooring Total ar Travel (FINISHE FLOOR TO FINISHE FLOOR) The inside Inside face Face of the Of Hoistway to To the Outside outside Of ar of Gate/ the ar Gate/ Limited to to 5" 5" y by SME 7. 203 & prior Prior Limited to to 4" 4" y by SME 7. 206 & and Florida Limited to to 3" 3" in in Georgia & and Massachusetts The Inside Face Of Hoistway To Hoistway Sill The inside face of the Hoistway to Hoistway Sill Limited to 3" y SME 7. 203 & Prior Limited y to SME 3" by 7. SME 206 7. 203 and Georgia, & prior Florida, and Massachusetts Limited by SME 7. 206 and Georgia, Florida and Massachusetts - 4" maximum when accordion doors are used. -¼" maxiumum when ccordion s are used 3 -¾" - maxiumum 4" maximum for other for other ar Gate/ car gate/door stylesstyles. ar ar Sill Sill To to Hoistway Sill running Running clearance learance (½" ¼") ( 2" - 4") imensions are required by SME 7. Typical Framework with rywall onstruction R 200# R2 400# Pit epth (FROM FINISHE FLOOR) Static Rail Reaction (Per Rail) symmetryelevator.com 877.375.428 3

Hoistway onstruction Outline Rail acking & General Hoistway Provide adequate rail backing per drawings. For vertical spans between floor systems that exceed 0'0," please consult a structural engineer. The wall must be capable of supporting the loads (two times the rail forces) without deflecting more than ⅛." The hoistway must be constructed square and plumb within ⅛" tolerance throughout. The hoistway must be free of any obstructions not related to the operation of the elevator (i.e. sprinklers, pipes, ducts, etc.). The structure of the hoistway must allow for installation of a chain hoist to transfer materials during construction. Provide hoistway doors that are a minimum of 3'0" x 6'8" and solid core construction. Pit Floor Provide a pit floor at a minimum of 6" (8 inches preferred) from the top of the finished floor to the highest point in the pit. (NOTE: Three speed car and landing doors require an 8-inch pit depth minimum.) Provide a pit floor capable of withstanding the impact load of 6,489 lbs. and the static load of 3,840 lbs. Overhead Inline Gear rive - Provide a minimum overhead of 8'0" for a 7'0" interior car height with a remote mounted controller. - Provide a minimum overhead of 9'0" for a 7'0" interior car height with an in-the-shaft controller. Hydraulic or Winding rum rive -Provide a minimum overhead of 7'0" for a 7'0" interior car height. Please note: If a Shaker, Recessed or Raised panel ceiling is used, an additional half-inch of overhead is required. rive-specific Items Inline Gear rive - Provide a minimum 8" x 8" access hatch at or near the top of the hoistway for manual lowering. (See drawings.) Winding rum rive - Provide a framed window between the machine room and the hoistway for passing of the suspension means. (See drawings.) Please note that this guide is for planning purposes only, applies exclusively to national code, and should not be used for construction. Prior to construction, please contact your local Symmetry Elevating Solutions representative and request a job-specific set of elevator plans to ensure that you obtain the accurate dimensions and requirements for your project. Your representative will also assist you to make sure that your project plans will comply with the applicable state and local codes and the building authority. 4 symmetryelevator.com 877.375.428

Inline Gear rive Remote ontroller Inline Gear rive Remote ontroller Travel able Hoistway to Machine Room onnections (6) 2 awg wires from Machine Room/(2) 8 awg wires from Machine Room Rail Structure Machine Stop Switch Manual rake Release Manual Lowering ccess rive Unit Please note that this layout is shown for manual lowering access at the top right of the view. The drive unit can be mounted opposite to accommodate access. Interlock Hoistway Note: ) Minimum overhead clearance as measured from the top of the upper landing sill 8'0" for a standard 7'0" car. *Feeding breaker must not be a G.F.I. **The control space temperature must be maintained between 32 F and 80 F. Motor ontroller isconnect (Fusible and Lockable) ar Light isconnect (Fusible and Lockable) 230 V, 20 amp, Single Phase (3 Wire edicated ircuit)* 5 V, 5 amp, Single Phase (edicated ircuit)* Telephone Service for Elevator Hoistway to Machine Room onnections (6) 2 awg wires and (2) 8 awg wires run to the top of the Hoistway Travel able Lockable Remote ontroller abinet (Standard 8" Wide x 8" High x 0" eep) (lternate 22" Wide x 30" High x 8" eep) must be located within 50'0" of the rive Unit 30" Wide x 36" eep lear Working Space Required in front of the Motor ontroller by National Electrical ode (NFP 70). symmetryelevator.com 877.375.428 5

Inline Gear rive emote ontroller ccess Hatch etail Hoistway to Machine Room onnections ccess Hatch (6) 2awg wires and (2) 8awg wires (Self losing) Run To The Top Of The Hoistway Travel able Inline Gear rive MRL ontroller ccess Hatch etail ccess Hatch 4 4 3 (Self losing) " From Rail Wall Inline Gear rive MRL ontroller achine Room onnections Motor ontroller isconnect (Fusible and Lockable) and Lockable) ar Light isconnect (Fusible and Lockable) s from machine room / (2) 8awg wires from machine room ar Light isconnect (Fusible and Lockable) and Lockable) 230V, 20 MP, Single Phase (3 Wire edicated ircuit)* 230V, MP, ** 20 amp, MotorSingle Phase (3-Wire edicated ircuit)* ircuit)* 5V, 5 MP, Single Phase (edicated ircuit)* Machine Stop Switch 5V, 5 MP, ** Motor ontroller 5 amp, Single Phase (edicated ircuit)* ircuit)* Plastic oated Service Light ulb With Guard Manual rake Release amp, ontroller Plastic-oated Service Light ulb with With Guard Guard Telephone Service Manual Lowering ccess Telephone Service for Elevator Machine Stop Switch rive Unit Machine Stop Switch Service Light Switch 5V GFI uplex Receptacle Interlock Service Light Switch Hoistway 5V G.F.I. GFI uplex Receptacle Manual rake Release Manual rake G.F.I. Release Manual Lowering ccess rive Unit Manual Lowering ccess hown for manual lowering access at the top right of the rive Unit Interlock unted opposite to accomodate access. Interlock Hoistway Please note that this Hoistway Travel layout able is shown for manual lowering access at Travel able Rail the top Structure right of the view. ce as measured from the top of the upper most landing sill The drive unit can be mounted opposite to Rail Structure accommodate access. ceiling is 8' - 0" for a standard 7' - 0" car. Please note that this layout is shown for manual lowering access at the top right of the Please note that this layout is shown for manual lowering view. access The drive at the unit top can right be of mounted the opposite to accommodate access. Notes: view. The drive unit can be mounted opposite to accommodate access. Notes: Minimum overhead clearance as measured from the top of the uppermost landing sill to the bottom of the shaft ceiling is 9'0" for a standard 7'0" car Notes: Minimum overhead clearance as measured from the top of the upper most landing sill The Minimum MRL ontroller overhead option clearance is not available as measured in all from jurisdictions, the top to of the please the bottom upper contact of most the your landing shaft local ceiling Symmetry sill is 9' Elevating - 0" for a Solutions standard representative 7' - 0" car. or local authority Motor ontroller isconnect to confirm to the bottom acceptance. of the shaft ceiling is 9' - 0" for a standard The 7' MRL - 0" ontroller car. option is not available in all jurisdictions, please contact your local (Fusible and Lockable) The MRL ontroller option is not available in all jurisdictions, Symmetry please Elevating contact Solutions your local representative or local authority to confirm acceptance. ar Light isconnect *Feeding Symmetry breaker Elevating must not Solutions be a G.F.I. representative **The control or local space authority temperature to confirm must acceptance. (Fusible and Lockable) *Feeding breaker must not be be maintained a G.F.I. between 32 F and 80 F. 230V, *Feeding 20 MP, breaker Single must Phase not be a G.F.I. ** The control space must be maintained between 32º to 80ºF. (3 Wire ** The edicated control ircuit)* space must be maintained between 32º to 80ºF. 5V, 5 MP, Single Phase (edicated ircuit)* Telephone Service For Elevator Inline Gear rive Inline Gear rive MRL ontroller MRL ontroller and ccess Hatch etail Motor ontroller isconnect (Fusible and Lockable) ccess Hatch etail 4¾" 4 4 3 " from From Rail Rail Wall Wall G.F.I. aintained between 32º to 80º F. 8" Min Lockable Remote ontroller abinet 8" Min (Standard - 8" Wide x 8" High x 0" eep) (lternate - 22" Wide x 30" High x 8" eep) Must e Located Within 50' Of The rive Unit. 30" Wide x 36" eep lear Working Space Required In Front Of The Motor ontroller y National Electrical ode (NFP 70). 8' 0" 7' 0" 7' " 6' 8" ab Height 03 2" 02 2" 87 2" 9 2" im to 8" Min 8" Min 8' 8'0" 7' 7'0" 7' 7'" 6' 6'8" ab ab Height 02 02½" 2" 03 03½" 2" 87 87½" 2" 9 9½" 2" im to to 207 ella Elevator LL.ll rights reserved. 0.09/7 6 symmetryelevator.com 877.375.428

r r Hydraulic rive Machine Rooms raulic rive Standard Machine Room Motor ontroller Hydraulic rive Standard Machine Room Hydraulic rive Standard Machine Room Room Hydraulic Line & Electrical To Hoistway 2" - 3 4" Plywood acking ehind rywall 48" 48" Light 48" Hydraulic Line & Electrical To Hoistway 2" - 3 to 4" Plywood acking ehind rywall Hydraulic Line Line & & Electrical To to to Hoistway ½" ¾" 2" - 3 4" Plywood acking behind ehind rywall Motor ontroller Motor ontroller Hydraulic Power Unit 48" 48" Hydraulic Power Unit Light Switch & uplex Receptacle Hydraulic Power Unit Light Switch & Light Light Light Switch uplex & Receptacle Switch & uplex Light Receptacle uplex 3'-0" MIN. Receptacle Self losing, Self Locking 3'-0" MIN. Motor ontroller isconnect Self losing, (Fusible and Lockable) Self Locking ar Light isconnect3'0" 3'-0" minimum MIN. (Fusible and Lockable) Self-losing, Motor ontroller isconnect Motor (Fusible and Lockable) 230V, 30 MP, Self-Locking Single Phase ontroller ar Light isconnect (3 Wire edicated ircuit)* (Fusible Motor and ontroller Lockable) isconnect Motor 5V, 5 MP, Single 230V, Phase (Fusible 30 and MP, Lockable) Single Phase ontroller (edicated ircuit)* (3 Wire ar Light edicated isconnect ircuit)* Motor ar Light isconnect Telephone Service For Elevator 5V, (Fusible 5 and MP, Lockable) Single Phase (edicated 230V, ircuit)* 230 V, 30 30 amp, amp, MP, Single Single Phase Phase Telephone (3-Wire Service edicated For Elevator ircuit)* 5V, 5 5 amp, MP, Single Single Phase Phase 5 V, 5 amp, Single Phase (edicated ircuit)* Travel able (edicated ircuit)* Telephone Service for For Elevator *Feeding breaker must not Travel be able a G.F.I. *Feeding breaker must not be a G.F.I. Light Light Switch & Switch & uplex Light uplex Receptacle Switch & Receptacleuplex 3'-0" MIN. Light LIGHT Receptacle 6" Self losing, Self Locking LIGHT 6" NOTES: r Machine Room Location nd Layout Must Meet Travel able quirements ) efined The Elevator y The Machine Local uthority Room Location Having nd Layout Must Meet. The ode Requirements efined y The *Feeding Local uthority reaker breaker Having must not be a G.F.I. 36" eep lear Jurisdiction. Working NOTES: Notes: Space In Front Of The Motor s Required 2) y National 30" Wide Electrical x 36" eep ode lear (NFP70). Working Space In Front Of The Motor ontroller Hydraulic itch Must e Located ontroller ) On s The Required Elevator Strike y Side National Machine Of The Electrical Room ode location (NFP70). ) The Elevator Machine Room Location nd Layout Standard and Must - layout Meet 8"W must X 8"H meet Motor X 0" the ontroller Power om. 3) The Light Switch The ode Requirements code Must requirements e Located On efined defined The Strike y The Local by the Side Of The Machine Room. lternate uthority local authority Having - 22"W Standard having x 30"H jurisdiction. x - 8" 8"W X 8"H X 0" Unit lic Power Unit Must e Located Within 40' Of The 4) The Jurisdiction. lternate - 22"W x 30"H x 8" Hydraulic 2) 30" Power Wide Unit x 36" Must eep e Located clear Within working 40' Of The 2) ylinder. 30" Wide x 36" eep lear Working Space In Front Hydraulic space in front Of The Motor Poewr of Unit the Motor e Room Must e Free Of ll ontroller Equipment as Not required Related by National Electrical ode (NFP Hydraulic 70). Poewr Unit 5) The ontroller Machine s Room Required Must e y Free National Of ll Electrical Equipment ode Not 33 (NFP70). Related ator. 2"H X 244"W X 33 2 Motor ontroller 3) To The The Light Elevator. Switch Must e Located On The Strike Side Of The 2"H 4" 3 X 244"W X 2 3) The light switch must be located on the strike side of 4" 3 Standard the - 8"W X 8"H X 0" Machine Room Machine. Room. lternate - 22"W x 30"H x 8" 4) The Hydraulic Power Unit Must e Located Within 40' Of The ylinder. 4) The Hydraulic Power Unit must be located within 40'0" of the Hydraulic cylinder. Poewr Unit 5) The Machine Room Must e Free Of ll Equipment Not Related 5) The Machine Room must be free of all equipment not related 33 To The Elevator. 2"H X 244"W X 24" 3 to the elevator. 6) The Machine/ontrol Room temperature must be maintained between 50 F and 80 F. 24" Hydraulic rive ompact Machine Room 24" Hydraulic rive ompact Machine Room Hydraulic Hydraulic rive ompact rive ompact Machine Machine Room Room 2" - 3 4" Plywood acking ehind rywall Hydraulic Line & Electrical To Hoistway LIGHT 24" Motor ontroller ½" ¾" 2" - 3 4" Plywood 2" - 3 acking ehind behind rywall 4" Plywood acking ehind rywall Hydraulic Line To Hydraulic & Electrical Line & to Electrical HoistwayTo Hoistway Motor 48" ontroller 48" Motor Hydraulic ontroller Power Unit Motor ontroller Hydraulic Power Unit 3'0" 3'-0" minimum MIN. 6" Self-losing, 6" Self Self-Locking 3'-0" MIN. 6" Self losing, 6" Self Locking Motor ontroller isconnect (Fusible and Lockable) ar Light isconnect (Fusible and Lockable) Motor ontroller isconnect Motor (Fusible and Lockable) ontroller 230V, 30 amp, MP, Single Phase (3-Wire ar Light isconnect edicated ircuit)* (Fusible and Lockable) Motor ontroller isconnec Motor 5V, 5 5 amp, MP, 230V, Single Single 30 Phase Phase MP, (Fusible Single and Phase Lockable) ontroller (edicated ircuit)* (3 Wire edicated ar Light ircuit)* isconnect Telephone Service 5V, for For 5 Elevator MP, (Fusible Single and Phase Lockable) (edicated ircuit)* 230V, 30 MP, Single Ph Telephone Service (3 Wire For edicated Elevator ircuit)* 5V, 5 MP, Single Ph (edicated ircuit)* Travel able Telephone Service For Eleva *Feeding breaker reaker must Travel must not able not be be a G.F.I. a G.F.I. *Feeding breaker must not be a G.F.I. Hydraulic Power Unit *Feeding breaker must not be a G Motor ontroller Standard 8"W x 8"H x 0" lternate 22"W x 30"H x 8" Hydraulic Power Unit Hydraulic Power Unit Travel able Hydraulic Power Unit 33½"H x 24¼"W x 2¾" symmetryelevator.com 877.375.428 7 48"

Winding rum rive Machine Room "" RIL Rail 24" Min "" The area where the the drive mounts must be be solid. solid, Use use a a ½" ½" 2" piece of of plywood to to fill fill the the gap gap in the in the backing backing below below the the window sheave cutout. cutout. Window Sheave utout etail etail utout "E" "E" Rail 24" Light Switch && uplex Receptacle "F" "F" 20" 84" Minimum Headroom 3'-0" 3'0" Self-losing minimum Self-Locking Self-losing, Self-Locking (y Others) (by others) 4" MIN Min 34" 30" 20" 26" 4" "" RIL Rail Motor ontroller 22" 7 2 " 7 2 " "" Motor ontroller isconnect (Fusible and and Lockable) ar Lighting isconnect isconnect (Fusible (Fusible and and Lockable) Lockable) 230 V, 30 30 amp, amp, MP, Single Single Phase Phase (edicated ircuit)* (edicated ircuit) * 5 V, V, 5 5 amp, amp, MP, Single Single Phase Phase (edicated ircuit)* (edicated ircuit) * Telephone Service onnection for Elevator * Feeding *Feeding breaker reaker must must not be not a be G.F.I. GFI a G.F.I. Window Sheave Winding rum rum Machine Machine 4 4 3 /6" 6 3 " 7 75 6 /6" " Travel-Specific imension hart Travel "" "" "" "" "E" "F" Up to 30'0" 48" min 24" min 3⅛" 9⅞" 0" 8⅝" Over 30'0" 60" min 36" min 9 5 /6" 28 3 /6" 2" 3" NOTES: Fill the back of the rail backing with 2" plywood below the window cutout. 26" FROM from MHINE Machine Room Floor ROOM FLOOR ) The Elevator Machine Room Location nd Layout Must Meet The Requirements efined y The Local uthority Having Jurisdiction 2) 30" Wide x 36" eep lear Working Space In Front Of The Motor Required y National Electrical ode (NFP70). 3) The Light Switch Must e Located On The Strike Side Of The Mac. 4) The Machine Room Must e Free From ll Equipment Not Related Elevator. Notes: Fill the back of the rail ½" with ½" of plywood below the window cutout ) The Elevator Machine Room location and layout must meet the code requirements defined by the local authority having jurisdiction. Travel Specific imension hart 2) 30" Travel Wide x 36" eep "" clear working "" space "" in front "" of the Motor ontroller as required by the National Up To 30' 48" Min. 24" Min. 3 /8" 9 7/8" Electrical ode (NFP 70). Over 30' 60" Min. 36" Min. 9 5/6" 28 3/6" 3) The light switch must be located on the strike side of the Machine Room. 4) The Machine Room must be free of all equipment not related to the elevator. 5) The Machine/ontrol Room temperature must be maintained between 32 F and 80 F. "E" 0" 2" 8 8 symmetryelevator.com 877.375.428

Optional Flush & Frame Flush & Frame Frame Width= = Width + 3¼" 34" Rough Opening= = Width + +4 4¼" 4" 2 6 /6" " 2 9 2 /6" 6 9 " Typical Frame 44 9 /6" 6 9 " Width Frame Hinges* Frame Height= = Height + + ⅜" 3 8" (Rough Opening Height= = Height ⅞") + ⅞" 7 8") Height Latch Guard Interlock & Interlock Handle (Optional) Nail Fin/Trim / Nail Nail Fin/Trim / Trim Height= = Height + 2⅝" 2 8" 5 Nail Fin/Trim / Width 3 5 6 /6" " Elevator Side ¼" 4 " ½" 2 " 5 /6" 5 6 " lear LER Opening OPENING 2½" 2 " Width 3 6 3 /6" " Notes: Flush ) The door/frame is suitable for installation in masonry or wood frame construction. 2) The door/frame is installed with the door flush to the inside of the hoistway. 3) The interior hoistway wall should be finished up to the rough opening. 4) This can be furnished as a frame only or complete door with frame. Roller all atch & Recessed Pull (Optional Features) ummy Handle (Optional) Latch Guard (Exterior View) Electronic Interlock (EML) symmetryelevator.com 877.375.428 9

I ontinuing Education www.symmetryelevator.com/aia Symmetry offers in-person and online course options to obtain continuing education credits. Each completed course is worth (one) LU/ HSW/S credit and provides a detailed review of residential elevators, vertical wheelchair lifts, and limited use/limited application (LU/L) elevators. Our continuing education I courses also address specification, code application, suitability of product type, and the direct governance and guidelines of the, NSI and SME. symmetryelevator.com 877.375.428