CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Similar documents
Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE LCC (Low Count Closure)

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

AMPLIMITE* HDP- 20 and Economy

Terminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

circuit protection & wiring accessories

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

FIBER CONNECTOR SAFETY WARNINGS

INTEGRID TRACK (120V) SPECIFICATIONS

POWER TRIPLE LOCK* Connector System

Single pole connectors

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

Access XL Electric Projection Screen by Draper

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

Assembly Instructions

Type MTS Miniature Test Switches

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

M GT 2005 up Mustang ENGINE START Push-Button INSTRUCTION SHEET

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

Desktop 5.5 Z Axis Retrofit

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems

Power In - Pathways Technology Wall

Installation Instructions: Read these instructions in its entirety before performing any installation work.

JUL 14 Rev B

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Installing Branch. Circuits. v One outlet cover V Wire nuts V Ground (gee) clip V Electrical tape

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

PFadvantage MF 6850/6855; Ideal 9080/9090

Installation Instructions: ACCENT SYSTEM

Electric Range installation manual

Terminator. DP Power Connection Kit INSTALLATION PROCEDURES

INTERWORKS EQ. Table of Contents. Panel System. Interworks EQ Kimball Legacy. Price List Effective Dates: Pricing Revision

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

PFadvantage Metalfor Araus 1360

COYOTE Terminal Dome Closure 6.5" x 22"

install o IIVIPORTANT - Savethese -&WARNING - -&WARNING - This appliance must -&WARNING - Before beginning the Mode_s PB970, PB975

*ININST.1002* 1690 Touchbar. Index:

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Installation Instructions

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Installation Instructions

SURFACE TRACK (120/250V) SPECIFICATIONS

Service Manual Mozart Fireplace

Part Name/Description Part Number Quantity Instruction Kit Metalfor Flow Sensor

Instructions for Use - Opt-X 1000i Enclosure

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

PLASTI-GRIP* Terminals and Splices

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC/NYLON

Designed for 2014 and newer 1500 Series and 2015 and newer Heavy Duty GM Silverado/Sierra Double Cab vehicles

Instruction Sheet for Powertite Plug, Connector and Receptacle

SPACESAVER EC-300 A ELECTRICS

CS Fiber Optic Splice Case. Instruction

RELOC Modular Wiring Specialty Lighting and Power Systems

Nonmetallic Thermoplastic Boxes Wall/Ceiling Boxes with Soft Box Characteristics

LEXUS GX TOWING HITCH Preparation

RECESSED TRACK (120V) SPECIFICATIONS

Electrical Accessories

INSTALLATION INSTRUCTIONS

RC3, RC7 & RC4 Receptacle Replacement

JODALE PERRY. Parts List & Mounting Instructions. Jacobsen HR9016 JDP BUILT FOR LIFE

Terminator DP/FAK-5 and FAK-5L

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

The steering column is of a modular construction and features easy to service electrical switches.

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

Installing Power Components

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

TS , -850 Series TS , -850 Series TS-57031, TS

Push Start Ignition (05-10 All) Installation

COYOTE STP (Service Termination Point)

BLACKBIRD INSTALLATION SUPPLEMENT

Connector Systems Inc. SS-20 MACHINE MANUAL

INSTALLATION PROCEDURE, HHT WITH BULKHEAD. Vehicle prep

w w w. h d o n l i n e s h o p. d e CRUISE CONTROL KIT GENERAL INSTALLATION -J04064 REV Kit Number Models Additional Parts Required

INSTALLATION MANUAL. Melink Corporation (513) Revision

Installation Instructions: Read these instructions in its entirety before performing any installation work.

WARNING. Important Notice

Assembly and Modular Table Power System Installation Instructions for Train Tables

Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Shaver Industries. Assembly Instructions Spring Assist Vertical Vinyl Curtain Door Projection Mount

Transcription:

This Product is Listed by UNDERWRITERS LABORATORIES INC. and Bears the Mark: This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark: SLATER SCD Installation Instructions For Self-Contained Devices Receptacles/Junctions and Switches Read these installation instructions before using Self-Contained Devices (SCDs) NOTICE: For factory installation in mobile homes, recreational vehicles, manufactured housing and for use in on-site construction. Use only nonmetallic grounded sheathed cable; Types NMB, NMC, NMD and NMD90* having copper conductors sizes #14 and #12 AWG. *CSA DESIGNATION SC070 SC071 SC073 SC080 SC08 CONTENTS DESCRIPTION PAGE Self-Contained Devices Explained............................ 2 DEVICES Receptacles/Junctions..................................... 2 Switches................................................ 2 WALL CUTOUT.............................................. 3 SLATER SCD INSTALLATION TOOLS........................... 3 CABLE PREPARATION........................................ 3 CABLE INSTALLATION FOR RECEPTACLES/JUNCTIONS & SWITCHES RECEPTACLES/JUNCTIONS In-Line.................................................. 4 End-of-Line.............................................. 4 Splice................................................... 4 Power Tap................................................ Power Tap & Splice....................................... SWITCHES In-Line.................................................. Power Tap............................................... 6 Power Tap & Splice........................................ 6 Splice................................................... 7 End-of-Line.............................................. 7 End-of-Line (alternate installation)............................ 7 3-Way Switches.......................................... 8 COMPLETING THE INSTALLATION.............................. 9 BACK COVER............................................... 9 SWING BRACKET MOUNTING................................ 10 SURFACE MOUNTING....................................... 10 REPLACING A SELF-CONTAINED DEVICE....................... 10 GANGING PROCEDURES.................................... 11 SNAP-ON WALL PLATES..................................... 11 Screw-Mounted Wall Plates................................ 11 TOOL MAINTENANCE................................ Back Cover BLADE CHANGING.................................. Back Cover SCD ANVIL KIT..................................... Back Cover SCD PLATE KIT.................................... Back Cover SC821 SC014

DESCRIPTION The Slater decorator style self-contained device consists of a Body Assembly and a Back Cover. The body and cover are molded from Hi-Impact resistant thermoplastic resin. The body assembly contains brass terminals. The back cover is designed to provide strain-relief at the cable openings when the assembly is closed. All device bodies are marked White Wire and Black Wire in the appropriate rear corners to identify the correct location for the installation of the cable conductors. In addition, there are raised ribs on one side of the device to further identify the White Wire (neutral) side of the device. The top mounting brackets on all of the devices have a raised dimple to identify the top end of the device. This allows the installer to be consistent by having all switches turned ON when the upper half of the operating paddle is depressed. This raised dimple also allows consistency in the positioning of the receptacle ground pin. For 3-way switches, the TOP marking has no significance, other than to simplify wiring. These features are provided to insure that wiring is in accordance with applicable electrical codes and standards. SWING BRACKET GREEN BODY ASSEMBLY GREEN RAISED RIBS ALSO IDENTIFY (NEUTRAL) CONDUCTOR SIDE TOP END OF DEVICE IDENTIFIED BY THE WORD TOP AND/OR A RAISED DIMPLE. CIRCUIT CONDUCTOR POSITION IDENTIFICATION DOUBLE LINE TERMINALS FOR EACH LINE CONDUCTOR GROUND TERMINAL SWING BRACKET LATCHES BREAK OFF TAB BACK COVER DEVICES RECEPTACLES CAT. NO Duplex 1 Amp/12 Volts SC080 Decorator 1 Amp/12 Volts SC08 Single 1 Amp/12 Volts SC821 SC830 20 Amp/12 Volts SC830-S* SC830-R* *Not Certified by Canadian Standards Association SWITCHES 1 AMP 120 VOLTS AC CAT. NO. S.P. (Single Pole) IN-LINE SC070-S SC070-R 3-WAY SC073-S SC073-R JUNCTION 20A /12 VOLTS CAT. NO. SC014-S Listed by Underwriters Laboratories Inc. and Certified by Canadian Standards Association as flush-mounted self-contained switches and receptacles. Self-contained devices are also UL Listed and CSA Certified for surface mounting. S suffix devices are for use on plasterboard 16" to 8" thick, and wood or composition paneling 32" to 8" thick. M suffix devices are for surface mounting on wood or steel studs. R suffix devices are replacement units for the same mounting limitations as S suffix devices and are supplied with a closing tool for installing the back cover. Additional suffixes 1, 2, 3, 4, and 6 identify device colors Brown, Ivory, White, Light Almond, Gray and Black respectively. Receptacles and single-pole switches are for use with two wire (with ground) nonmetallic sheathed cable. Three-way switches are limited to use in circuits where the branch circuit power cable is installed at the load location. See wiring diagram on Page 8 for illustration. 2

WALL CUTOUT USE DIMENSIONS SHOWN BELOW SLATER SCD INSTALLATION TOOL The Slater hand tool catalog number SCD-TOOL is designed to slit and form flat nonmetallic sheathed cable (NMB, NMC, NMD and NMD90* copper cable #12-2 and #14-2 with ground) and to install the cable into the self-contained device body assembly. *CSA DESIGNATION NOMINAL CUTOUT DIMENSIONS Single gang: 3 3 8" x 1 11 16" Two gang: 3 3 8" x 3 1 2" Three gang: 3 3 8" x 16" Four gang: 3 3 8" x 7 1 8" Five gang: 3 3 8" x 8 1 16" Six gang: 3 3 8" x 10 3 4" *CABLE PREPARATION ASSEMBLY (SCD ANVIL KIT) *INCLUDES CABLE PREPARATION BLADES AND CABLE PREPARATION CHANNEL CABLE INSTALLATION (SCD PLATE KIT) DEVICE POSTS CATALOG No. SCD-TOOL CABLE PREPARATION SLITTING AND FORMING THE CABLE Slitting the cable jacket with the Slater SCD-TOOL forms each conductor to match the inner terminal configuration of the switch or receptacle. The tool will produce a slit length of less than 2.0" maximum allowable slit. Prepare conductors as illustrated in the section Cable Installation for Receptacles/Junctions & Switches. 12-lNCH LOOP AND 6-INCH END-OF-LINE Where an In-Line cable is located at a device opening in a wall, there must be at least a 12" length of cable available on the room side of the wall to allow cable preparation and possible future device replacement (NEC Requirement). For end-of-line, power tap or splice applications, a minimum 6" length of cable must be available on the room side of wall. For all installations the cable must be secured within 12" from the wiring device wall opening. With tool handles opened, place cable in the cable guide of cutter section. 1. Be sure cable lies flat in the cable guide. 2. Grip tool handles and squeeze together until tool is fully closed (handles are parallel.) 3. Open tool handles fully and carefully remove the formed cable. NOTE: After slitting, if cable is to be used for an In-Line receptacle, it is ready for installation. It is not necessary to remove the cable sheathing or paper filler. For all other applications, trim outer sheathing and paper filler from the slit length. Refer to CABLE INSTALLATION FOR RECEPTACLES/JUNCTIONS & SWITCHES for details of wiring methods. 3

CABLE INSTALLATION FOR RECEPTACLES/JUNCTIONS & SWITCHES WARNING: Do not join two (2) different wire sizes in a self-contained receptacle or switch. RECEPTACLES/JUNCTIONS (CAT. NOS. SC080, SC08, SC014, SC821, SC830) IN-LINE RECEPTACLE Single cable running through a receptacle. The cable may be installed with the sheath and paper filler left in place. If a second level of cable is anticipated (i.e. power tap) all the sheath material and paper filler must be removed from the entire slit length of each cable. RIBS REF. GROUNDING IN-LINE END-OF-LINE RECEPTACLE An end-of-line receptacle must have each line conductor extending approximately 1 4" beyond its double line terminal as shown. SPLICE A splice is an installation where two (2) cable ends terminate in a SCD i.e. one cable bringing power to a receptacle or junction and a second cable going to another load. NOTE 1: Each circuit conductor of the cable ends must be installed so that it engages its respective double line terminals as shown. NOTE 2: Two cables may exit from opposite ends of device as shown, or from one end only. (not shown) END-OF-LINE SPLICE NOTE: All cable installations shown must have all sheath material and paper filler removed from the entire slit length of the cable. (Continued on next page) 4

CABLE INSTALLATION FOR RECEPTA- CLES/JUNCTIONS & SWITCHES (Con t) NOTE: All cable installations shown on this page must have all sheath material and paper filler removed from the entire slit length of the cable. RECEPTACLES/JUNCTIONS (Continued) POWER TAP A power tap is an application using a self-contained device with a second level of conductors installed in the device terminals on top of the branch circuit cable. The power tap may be an in-line cable (one cable going out each end of the receptacles to two other load locations), or may be a single cable going to one load location. In the latter case, each circuit conductor must be installed with approximately 1 4" extending beyond its double line terminal as shown. POWER TAP AND SPLICE A power tap may be made on a receptacle or junction which is used for splicing two cable ends. For #12 cable, the wire insulation must be stripped from two of the three conductors as shown in A and B. It is not mandatory to strip the wire insulation off the conductors when using #14 cable. The stripped conductor cables A and B must be installed in the receptacle body first, one on top of the other. Conductor cable C which has not been stripped must be placed in last, on top of the stripped conductors. A C A C *Strip 1 1 8" 1 1 8" LAY IN LAST ON TOP POWER TAP *#12 wire only B POWER TAP & SPLICE B SWITCHES IN-LINE (CAT. SC070) The black insulated conductor of the single cable running through the device must have a short length cut out (approx. 1 4" to 3 8") between terminals and all the sheath material and paper filler must be removed from the entire slit length of the cable. 16" (Continued on next page) IN-LINE

CABLE INSTALLATION FOR RECEPTA- CLES/JUNCTIONS & SWITCHES (Con t) NOTE: All cable installations shown on this page must have all sheath material and paper filler removed from the entire slit length of the cable. SWITCHES (Continued) POWER TAP (CAT. SC070) A power tap is an application using an in-line switch for a second level of conductors installed in the device terminals under the in-line cable. The power tap may be either switch controlled or always energized by installing the tap under the load-end or feed-end of the first level cable. Be certain to maintain continuity of the grounding conductor to the load when installing a power tap. POWER TAP AND SPLICE (CAT. SC070) A power tap may be made on a switch which is used for splicing 2 cable ends. This tap may also be either switch controlled or always energized. All three grounding conductors must be joined in the ground terminal. For #12 cable, the wire insulation must be stripped from two of the three conductors as shown in A and B. It is not mandatory to strip the wire insulation off the conductors when using #14 cable. The stripped conductor cables A and B must be installed in the switch body first, one on top of the other. Conductor cable C must be placed in last, on top of the stripped conductors. A C A C 3 4" 16" POWER TAP *Strip 1 1 8" 3 4" LAY IN LAST ON TOP POWER TAP (CAT SC070) The power tap cable may provide one switched end and one always energized if it is also a feedthrough cable. (Black conductor of both levels of cable must be severed as shown.) B *#12 wire only POWER TAP & SPLICE B 16" 6 (Continued on next page)

CABLE INSTALLATION FOR RECEPTA- CLES/JUNCTIONS & SWITCHES (Con t) NOTE: All cable installations shown on this page must have all sheath material and paper filler removed from the entire slit length of the cable. SWITCHES (Continued) SPLICE (CAT SC070) A splice is an installation where two (2) cable ends terminate in a SCD i.e. one cable bringing power to a switch and a second cable going to the load. A device used to splice two (2) cables can also provide a POWER TAP (see page 6). END-OF-LINE (ALTERNATE INSTALLATION WITH CAT. SC070) A Cat. No. SC070 may be used for an end-of-line installation by looping the white conductor and terminating as shown. Cut off ground conductor flush with cable sheath. The ground terminal will not be used for end-of-line installations. 3 4" 2 3 4" CUT LENGTH 16" SPLICE END-OF-LINE 14-3 IN FROM FAN-LIGHT FAN SWITCH (SINGLE POLE) CONTROL OF CEILING FAN/LIGHT WITH 2 SINGLE-POLE SWITCHES NOTE: CUT-OFF GROUND LIGHT SWITCH (SINGLE POLE) 2 3 4" CUT LENGTH 14-3 HOT-IN 3 4" HOT TO JUMPER FAN-SWITCH LEG RED LIGHT- SWITCH LEG CUT OFF GROUND LIGHT- SWITCH JUMPER LEG JUMPER 14-2 CUT OFF GROUND HOT-IN 7 (Continued on next page)

CABLE INSTALLATION FOR RECEPTA- CLES/JUNCTIONS & SWITCHES (Con t) NOTE: All cable installations shown on this page must have all sheath material and paper filler removed from the entire slit length of the cable. SWITCHES (Continued) 3-WAY SWITCHES (CAT. SC073) The power feed cable is run to the load. A two wire cable is run from load to the first 3-way switch and a three wire cable is run from first to second 3-way switch (see diagram). The branch circuit power cable must be installed at the load location as shown. NOTE: Ground conductors should be cut off with cable sheath at both ends of cables connected to three-way switches. 3 4" 16" 3-WAY SWITCHES STRIP 2 1 2" CABLE: 3 RED STRIP GND. POWER FEED CABLE FROM SOURCE (2 WITH GROUND) (INTERNAL SHUNT) NOTE: RED & CONDUCTORS SPLICED HERE COMMON (INTERNAL SHUNT) COMMON LOAD (SEE NATIONAL ELECTRICAL CODE PARAGRAPH 200-7, EXCEPTION 2) REAR VIEW OF SWITCHES STRIP 1" CABLE: 2 WARNING: Do not join two different wire sizes in a self-contained device. (i.e. 14-3 wire to be used only with 14-2 and 12-3 with 12-2). 8

COMPLETING THE INSTALLATION USING INSTALLATION TOOL NO. SCD-TOOL 1. Insert the device to be wired face down onto the device posts of the SCD-TOOL. Carefully position the conductors over the device terminals. By fully closing the tool handles, the Cable 2. Installation Plate will push the cable conductors into the device terminals. For additional layers of cable, repeat the process. After all cables have been installed, inspect the wire lay, and if satisfactory, snap the back cover into the 3. device. The device is now ready to be installed in the wall. BACK COVER The back cover may be used for either a switch or a receptacle, and may be installed in either possible orientation on the device. As molded, the back cover allows an opening for one cable and when installed in the body assembly. For additional cable openings, break off tabs as follows: For in-line or end-of-line 1 cable in and 1 cable out configuration, break off one level of the longer tab. For power tap or power tap and splice configuration with 2 cables in and 1 cable out configuration break off the longer tab. For power tap with 2 cables in and 2 cables out configuration break off the long and short tabs. NOTE: To comply with N.E.C. requirements, there must be no unoccupied cable openings in the installed device. CAUTION: Each cable opening is not intended for more than two cables. 9

SWING BRACKET MOUNTING (Cat. No. with Suffix S or R ) The Slater swing bracket devices are designed for use on dry wall 16" to 8" thick, and on wood or composition paneling 1 32" to 8" thick. 1. Push the device into the dry wall or panel cutout until the mounting bracket is flush against the wall surface. 2. Using a number 2 type 1A Posidriv screwdriver, turn the screw head clockwise (which turns the swing bracket to the upright position) and tighten the swing bracket until the device is secured to the wall. IMPORTANT NOTE: This device can be installed anywhere between studs. If mounted adjacent to a stud, no additional space is necessary to clear travel of swing bracket. SURFACE MOUNTING Slater self-contained devices are UL Listed and CSA Certified for surface mounting on wood and steel studs. (Cat. No. with Suffix S or R ) 1. Remove the two screws and swing brackets from the device by backing out the screws through the front of the device. 2. Replace the screws removed in Step 1 with two #6 x minimum 1 3 4" long wood screws or sheet metal screws. 3. Secure the device to the mounting surface. (Cat. No. with Suffix M ) 1. Insert two #6 x 1 3 4" self-tapping screws (supplied in device carton) into the round openings on the face of the device. 2. Secure the device to the mounting surface. WOOD STUD MOUNTING STEEL STUD MOUNTING REPLACING A SELF-CONTAINED DEVICE If a SCD should require replacement, use one of the following replacement devices: SC070-R Single Pole In-Line Switch SC073-R Three-Way Switch SC08-R Decorator Receptacle SC821-R Single 1 AMP Receptacle SC830-R Single 20 Amp Receptacle 10

GANGING PROCEDURES Install in wall as follows: A. TWO-GANG 1. Position devices next to each other in wall cutout made by using 2-gang routing template, Cat. No. SCT-2T 2. Snap positioning guide, Cat. No. SCT-7 onto devices. This will automatically position and space devices. Secure devices to wall and remove positioning guide. Install wall plate. B. THREE-GANG 1. Position devices next to each other in wall cutout made by using 3 gang routing template, Cat. No. SCT-3T 2. Snap positioning guide, Cat. No. SCT-7 onto two devices. This will automatically position and space two devices. Secure devices to wall and remove positioning guide. 3. Snap positioning device onto remaining device and the one adjacent to it (already installed). Secure the third device to wall and remove positioning guide. Install Standard Decorator screw mounted wall plate. C. FOUR, FIVE OR SIX-GANG 1. Position device in wall cutout specified on page 3 and proceed as described in B. Use Standard Decorator screw mounted wall plate (see below). SNAP-ON WALL PLATES Designed to be used in conjunction with any one or two gang Slater SCD installations. To install a SNAP-ON WALL PLATE: 1. Align wall plate locking tabs to square holes in mounting straps. 2. Press firmly until locking tabs snap into place. To remove wall plate, pry outward until locking tabs release. The plate can be removed and reinstalled without loss of retention force. Single gang and double gang screw mounted wall plates may be used instead of snap-on wall plates, if preferred. DESCRIPTION CAT. NO. COLOR Single Gang SNAP-11 Brown SNAP-12 Ivory SNAP-13 White SNAP-14 Light Almond Two Gang SNAP-21 Brown SNAP-22 Ivory SNAP-23 White SNAP-24 Light Almond SNAP-1_* SCREW MOUNTED WALL PLATES For ganged installation, use screw mounted wall plates. (Single and double (two) gang screw mounted wall plates may be used instead of snap-on wall plates, if preferred.) SNAP-2_* * Replace _ with color number to specifiy color choice: 1-Brown, 2-Ivory, 3-White, 4-Light Almond 11

TOOL MAINTENANCE Keep tool clean. Spray operating parts with a commercial silicone lubricant to insure trouble-free operation. Check blades for nicks or dull edges and replace as necessary. NEW SCDTOOL ANVIL RETROFIT KIT (CAT. NO. SCDANVILKIT) 1. Remove old anvil (A). 2. Replace old blades, spacers and safety shield according to the SCDBLADE instructions as shown below. Leave screws loose. 3. Open Tool 4. Attach new anvil to tool using the two screws (B) provided, leave loose. NEW SCDTOOL INSTALLATION PLATE RETROFIT KIT (CAT. NO. SCDPLATEKIT) 1. Remove old installation plate (D) and discard. 2. Using the two flathead screws (E), firmly attach the adapter plate (F) to the SCDTOOL such that the pin on the adapter plates does not interfere with the tool. 3. Loosely attach the installation plate (G) to the adapter plate using the two pan-head screws (H) such that the pin on the installation plate fits into the slot on the adapter plate.. Slowly close tool. Be careful not to damage blades while closing. 6. Tighten the blade assembly screws (C). 7. Tighten the anvil screws (B). 8. Open and close tool slowly to see if there is any interference, if so, re-align. The blades will typically ride very closely to the center web of the anvil this is normal. 4. Put a Slater SC08 receptacle into the device holder and close tool slowly so that the teeth on the installation plate properly straddle the terminals of the device.. Tighten the pan-head screws (H). 6. Open and close tool to assure that there is no interference. If so, loosen the plate and re-align. BLADE CHANGING FOR INSTALLATION TOOLS USE REPLACEMENT BLADES CAT. NO. SCD-BLADES Remove two slotted head screws (C), remove two blades and install replacement matched set. Close tool before tightening screws so that the blades align properly. Tighten the two slotted head screws C SAFETY SHIELD USE REPLACEMENT BLADES (CAT. NO. SCD-BLADES) SPACERS SCDTOOL ANVIL RETROFIT KIT (CAT. NO. SCDANVILKIT) NOTE: Inset diagram reversed for clarity. B A G E SCDTOOL INSTALLATION PLATE RETROFIT KIT (CAT. NO. SCDPLATEKIT) D F SLATER SCD INSTALLATION TOOL H 7/01 340726 Rev. B 200 Pass & Seymour/Legrand Printed in USA