and Accelerometers Bently Nevada* Asset Condition Monitoring

Similar documents
and Accelerometers

Caution. Description. Specifications and Ordering Information and Accelerometers

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

Hydro Stator End Winding Accelerometer System

Hydro Stator End Winding Accelerometer System

Proximity Transducers, Seismic Sensors and Accessories

PPT 802, Proximity Probe Transducer System

Industrial Monitoring Instrumentation

3300 XL High-Pressure Feedthrough

Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual

Type 2REX-A. Oil & Gas / Heavy Industry

Proximity Transmitters, and Seismic Vibration Transmitters

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Monitor and Transducer Verification Kits

Operation Manual Bently Nevada Asset Condition Monitoring

MODEL 205 ce VIBRATION METER

Proximity Transmitters, and Seismic Vibration Transmitters

Fisher i2p 100 Electro Pneumatic Transducer

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

Seismic Sensor Accessories SA, SV & ST 6000 Series

Railway vibration measurement. Enhance safety and cut maintenance costs

TX5634 to TX5639 Data Sheet

Model 648A ma Output Accelerometer. Installation and Operating Manual

Описание на системы датчиков воздушного зазора. Модель 4000

Product Manual MNX10003 / REV C MODEL MH130 MODEL MH101-1B MODEL MH107-1B / MH107-1A MODEL MH118

Acceleration Sensor AS - 030

Sensors for Road Load Measurements Accelerometers, Pressure Sensors, Force Sensors, Strain Sensors, Load Cells, and Signal Conditioners

Installation Manual A Digital Tachometer. Part Number Rev. H (09/07)

Instruction Manual. Vibration Severity Meter VM12

Product Manual MNX10003 / REV B MODEL MH130 MODEL MH101-1B MODEL MH107-1B / MH107-1A MODEL MH118

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

PXT-K Series. Pressure Transmitters Section 05

Product specification

FasTrak High Capacity Smart Positioner

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Load and Motor Switches, Load-Break Switches Series 8544

Eddy Probe Systems Catalog. Probes and drivers Mounting devices Housings Pressure feedthroughs Calibrators and simulators Accessories

Sentronic PLUS 614 Series

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog SIL 2 capable Data Sheet

VIBRATION SENSORS VIBRATION SENSORS

Product specification

APG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

Series Level-Trol Electronic Liquid Level Transmitters

HX-P420 SERIES 4 to 20 ma OUTPUT

Product specification

Model 643A ma Output Velocity Sensor. Installation and Operating Manual

Continuous Duty Torque Measurement. Directly and accurately measures the power of turbomachinery in the Oil, Gas and Petrochemical industries.

Acceleration sensors (ICP technology) VBS 50 overview Configurations

Mobrey MSM400 Ultrasonic sludge density measurement system

Weatherproof Tubular Slip Ring Assembly

RK 4 Rotor Kit. Description

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Load and Motor Switches, Load-Break Switches Series 8549

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

HCA & HCA-RA SERIES Hermetically Sealed AC LVDT

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

Models 4700P/4700E & 4800P/4800E

Fisher 3660 and 3661 Positioners

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

0745A Load Cell. Global Usage Fully Approved for Accuracy and Safety. 0745A Beam Load Cell Fully Approved

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

Type Type 1001 Transducers. I/P & E/P Transducers

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

Safety Standards. Model Number:

TZIM. Electropneumatic Analog Positioner 10/ EN

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

Type Type I/P & E/P Transducers

Electropneumatic positioner APIS

Assembly. Trunk IN + - S U, I U, I. Spur 1

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

GETTING STARTED GUIDE NI DO, 5 V to 30 V, Sourcing, 1 μs

GETTING STARTED GUIDE NI DO, 6 V to 30 V, Sourcing, 100 μs

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

SRS SEALED ROTARY SENSORS

Paddle-wheel flow controller for On/Off control

GETTING STARTED GUIDE NI AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

2100 Turbine Flow Sensor

Magnetic-inductive flow meter for hazardous areas

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

MS Application. Features. Proportional Valve Actuator General Instructions

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

APS 113 ELECTRO-SEIS Long Stroke Shaker with Linear Ball Bearings Page 1 of 5

Capacitive level sensors CLS 23

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

G2 Industrial Grade Meters

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

Transcription:

200350 and 200355 Accelerometers Bently Nevada* Asset Condition Monitoring Description The 200350 and 200355 Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster* Pro Constant Current Direct Input Card 149811-02 and the Seismic Direct Input Card 164746-01. ACCELEROMETER The 200350 and 200355 Accelerometers are contained within a hermetically sealed, stainless steel case. The design provides an extremely rugged transducer, well suited for harsh industrial environments. Each transducer s top mounted, 2-pin connector (MIL-C- 5015) allows for easy installation and removal of the interconnecting signal cable. A ¼-28 threaded hole on the bottom of the casing accommodates multiple mounting options. The 200350 and 200355 Accelerometers contain a piezoelectric sensing device, which generates charge when subjected to vibration. This charge is then converted electronically to a differential voltage signal, which is proportional to the acceleration that is parallel to the sensitive axis of the transducer. Application Alert If housing measurements are being made for overall protection of the machine, consider the usefulness of the measurement for each application. Most common machine malfunctions (imbalance, misalignment, etc.) originate at the rotor and cause an increase (or at least a change) in rotor vibration. For housing measurements alone to be effective for overall machine protection, a significant amount of rotor vibration must be faithfully transmitted to the bearing housing or machine casing, or more specifically, to the mounting location of the transducer. In addition, exercise care in the physical installation of the transducer. Improper installation can result in a degradation of the transducer s performance and/or the generation of signals that do not represent actual machine vibration. Upon request, we can provide engineering services to determine the suitability of housing measurements for the machine in question and/or to provide installation Page 1 of 10

Specifications Parameters are specified from +20 to +30 C (+68 to +86 F) and 100 Hz unless otherwise indicated. Electrical Sensitivity Frequency Range ( 3 db) Measurement Range Transverse Sensitivity Amplitude Linearity Mounted Resonant Frequency Broadband Electrical Noise (1-10kHz) Output Bias Voltage Excitation Voltage Constant Current Excitation Settling Time (within 1% of bias) Output Impedance Discharge Time Constant Electrical Isolation (Case) Application Alert Operation outside the specified limits will result in false readings or loss of machine monitoring. 200350 200355 100 mv/g 20% (10.2 mv/m/s^2 20%) 30-600,000 cpm (0.5-10,000 Hz) 50 g 100 mv/g 5% (10.2 mv/m/s^2 5%) 12-600,000 cpm (0.2-10,000 Hz) 7% 5% 1500 kcpm (25 khz) 350 µg (3,434 µm/s 2 ) 2.0 sec ± 1% 8 to 12 VDC 18 to 28 VDC 2 to 20 ma 1250 kcpm (20.8 khz) 50 µg (491 µm/s 2 ) 5.0 sec < 150 ohms < 100 ohms 0.3 sec > 10 8 ohms 0.8 sec Environmental Operating Temperature Range Shock Survivability Relative Humidity Enclosure Rating Physical Hex Size Height Weight Mounting Thread Mounting Torque (Maximum) Sensing Element Sensing Geometry Housing Material Sealing Electrical Connector Electrical Connection Position -65 to +250 ºF (-54 to +121 ºC) 5,000 g pk 100% relative, condensing, non-submerged IP68 200350 200355 11/16 7/8 (18 mm) (22mm) 1.65 2.06 (42.4 mm) (52.3 mm) 1.8 oz 3.3 oz (51 grams) (94 grams) 1/4-28 Female 2 to 5 ft-lb (2.7 to 6.8 N-m) Ceramic Shear Stainless Steel Welded Hermetic 2-Pin Mil-C-5015 Top Page 2 of 10

Hazardous Area Approvals For a detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide, document 108M1756, at www.gemeasurement.com. 200350 Accelerometer Intrinsically Safe Intrinsically Safe and Non- Incendive CSA/NRTL/C (Approval Option 01) Ex ia IIC T4 Class I, Division 1, Groups A, B, C and D AEx ia IIC T4 Class I, Division 1, Groups A, B, C and D T4 @ -54 C Ta +121 C (-65.2 F Ta 249.8 F ) per drawing 175825 Ex nl IIC T4 Class I, Division 2, Groups A, B, C and D AEx na T4 Class I, Division 2, Groups A, B, C and D T4 @ -54 C Ta +121 C (-65.2 F Ta +249.8 F ) per drawing 175825 ATEX/IECEx (Approval Option 01) T4 @ -54 C Ta +121 C (-65.2 F Ta +249.8 F) II 1 G Ex ia IIC T4 Ga II 3 G Ex na IIC T4 Gc 200355 Accelerometer The 200355 accelerometer does not have hazardous area approvals at this time. Accessories 200350 and 200355 Accelerometer Manual Trendmaster* Pro System Manual Trendmaster DSM Datasheet Trendmaster DSM Manual Mounting Studs 168303-01 162411 149831-01 149823-01 Dimensional diagrams of all available mounting studs are shown in Figure 8. ¼-28 Mounting Stud M6x1 Mounting Stud M8X1.25 Mounting Stud 164373 164372 167559 Compliance and Certifications Electromagnetic Compatibility (EMC) Standards EN 61326-1:2013 Directives EMC Directive 2014/30/EU Page 3 of 10

Adhesive Mounting Kits Adhesive studs are sold in kits containing two threaded studs and two mounting pads. Also in the kit is a packet of acrylic adhesive and materials to mix its two components. A scouring pad and alcohol wipe are provided for preparing the mounting surface. Temperature Range: -67 to +250 ºF (-55 to 121 ºC) Cure Time: 24 hours ¼-28 Adhesive Mounting Kit M6x1 Adhesive Mounting Kit M8X1.25 Adhesive Mounting Kit Magnetic Base Kit 167563-10 167563-11 167563-12 The magnetic base has a pull of 35 lbf and it is suitable for placement on both curved surfaces and flat surfaces. The magnet comes supplied with a ¼-28 mounting stud. A dimensional diagram of the magnetic base is shown in Figure 9. Magnetic Base w/ Mounting Stud Application Alert Use of adhesive will attenuate high frequency components that may be present. 286244 Cables The Splash proof cable is not recommended for the model 200350 accelerometer. The standard cables are 22 AWG 2-conductor twisted shielded pairs with 2-socket moisture-resistant female connector at one end, terminal lugs at the other end. Cable length is optional and comes in increments of 1 ft between the stated maximum and minimum lengths. Splash Proof Cable Standard Cable, No Armor CB2W100 AXXX A: Length 0 1 5 15 ft 0 3 2 32 ft 0 6 4 64 ft 1 1 2 112 ft 1 2 5 125 ft 1 5 0 150 ft 2 0 0 200 ft 2 5 0 250 ft 9571 AXX A: Length 0 2 Minimum length, 2 ft 9 9 Maximum length, 99 ft x x Desired length in ft The following are standard lengths Feet Metres (approx.) 6 1.8 8 2.4 10 3.0 12 3.6 15 4.5 17 5.0 20 6.0 25 7.6 30 9.0 33 10.0 50 15.2 99 30.0 NOTE: Non-standard/custom lengths can also be ordered at additional cost Page 4 of 10

Standard Cable, Armored 84661 AXX A: Length 0 3 Minimum length, 3 ft 9 9 Maximum length, 99 ft x x Desired length in ft The following are standard lengths Feet Metres (approx.) 6 1.8 8 2.4 10 3.0 12 3.6 15 4.5 17 5.0 20 6.0 25 7.6 30 9.0 33 10.0 50 15.2 99 30.0 NOTE: Non-standard/custom lengths can also be ordered at additional cost 200355 Accelerometer 200355 AXX BXX - CXX A: Mounting Stud B: Tolerance C: Approvals 0 0 ¼-28 SS w/ Brass tip, 0.5 0 1 ¼-28 to M6 x 1.00 BeCu 0 2 ¼-28 to M8 x 1.25 BeCu 0 9 No mounting stud 1 0 ¼-28 Adhesive Stud Mount 1 1 M6x1 Adhesive Stud Mount 1 2 M8x1.25 Adhesive Stud Mount 1 3 Magnetic Base Kit 0 0 100 mv/g 5% (10.2 mv/m/s^2 5%) 0 0 No approvals Ordering Information For a detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide, document 108M1756, at www.gemeasurement.com. 200350 Accelerometer 200350 AXX BXX - CXX A: Mounting Stud 0 0 ¼-28 SS w/ Brass tip, 0.5 0 1 ¼-28 to M6 x 1.00 BeCu 0 2 ¼-28 to M8 x 1.25 BeCu 0 9 No mounting stud 1 0 ¼-28 Adhesive Stud Mount 1 1 M6x1 Adhesive Stud Mount 1 2 M8x1.25 Adhesive Stud Mount 1 3 Magnetic Base Kit B: Tolerance C: Approvals 0 0 100 mv/g 20% (10.2 mv/m/s^2 20%) 0 0 No approvals 0 1 CSA, ATEX, IECEx Page 5 of 10

Graphs and Figures ACCELEROMETER Figure 1. 200350 Accelerometer Dimensional Drawing Page 6 of 10

Figure 2. 200355 Accelerometer Dimensional Drawing Page 7 of 10

Figure 3. 200350 Accelerometer Frequency Response Figure 4. 200350 Accelerometer Phase Figure 5. 200355 Accelerometer Frequency Response Figure 6. 200355 Accelerometer Phase Page 8 of 10

Figure 7. Temperature Sensitivity Curve ¼-28 Stud M6x1 Stud M8x1.25 Stud Figure 8. Mounting Stud Dimensional Drawings Page 9 of 10

Figure 9. Magnetic Base Dimensional Drawing * Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company. The information contained in this document is subject to change without notice. 2003-2016 Bently Nevada, Inc. All rights reserved. Printed in USA. Uncontrolled when transmitted electronically. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 775.782.3611 Fax: 775.215.2873 www.gemeasurement.com Page 10 of 10