Translation of ORIGINAL ARTICLE Issue:

Similar documents
TECHNOLOGY IN MOTION MACO MULTI-TREND TU.-ON. AND T&T FITTINGS. Installation instructions TIMBER WINDOWS

Roto NT. Window and Door Technology. The world s biggest selling Tilt&Turn hardware system for windows and balcony doors

Hardware Solution for Windows

Roto NT. Window and door technology. The world s biggest selling Tilt&Turn hardware system for windows and balcony doors

Hardware Solution for Windows

ALU 5200-TBT (150 kg)

Note to users: This electronic document is not subject to copyright. You may copy it, but you are requested not to disseminate altered copies.

Patio doors max. Sash width (mm) 600 to Sash height (mm) 550 to Sash weight (kg) max. 150 max. 150

ALU axxent PLUS-DK KPW

COMMISSION REGULATION (EU)

Exchange of rollers from the XTS-Mover

Assembly instructions PORTAL. SOFT CLOSE with guiding rail SC001 Timber. Window systems Door systems Comfort systems

Common position by FR and CEMA on mechanical couplings for towed vehicles 28/9/2015

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Patio doors max. Sash width (mm) 380 bis Sash height (mm) 550 bis Sash weight (kg) max. 100/130 max. 100/130

2 tilt only stays min. max. Sash width (mm) > Sash height (mm) Sash weight (kg) max. 30 kg max.

CETOP POSITION PAPER PP 07

VAG CEREX M300 Butterfly Valve

WELDLESS CHAIN SPECIFICATIONS

TECHNOLOGY IN MOTION MACO. TU.-ON. and T&T FITTINGS. Comfort fittings

The following information from the aluminium planning manual must be observed:

Roto Patio Alversa. will be available soon. Roto Patio Alversa PS Air. Window and Door Technology

MG12K24T60V4 Mechanical Grapple

Porte 150 Users Manual Swing Gate Opener 24V DC

HST -LS Interlocking device (Translation of Original Manual)

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

Mounting and Service Instructions

SOLAR HEATING SYSTEM

OPERATING INSTRUCTIONS

Instruction manual and installation guide Traction sheave brake TSB TSB

SFI SPECIFICATION 16.5 EFFECTIVE: DECEMBER 29, 2014 *

Installation, Operation, and Maintenance Manual

Temperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets

MCHT-350 MAGNETIC CYLINDER HAND TRUCK INSTRUCTION MANUAL

Roto NT Designo. Window and Door Technology. Concealed hinge solution for windows and balcony doors with high sash weights up to 150 kg

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Umatilla Electric Cooperative Net Metering Rules

TSCHAN -B. Installation and Operation Manual TSCHAN Flexible Coupling BAWB 001-GBR-0 06/2004

Instructions for Use

Support legs. Installation and operating instructions

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

REAR SUSPENSION GROUP CONTENTS GENERAL DESCRIPTION REAR SUSPENSION DIAGNOSIS LOWER ARM AND TOE CONTROL ARM ASSEMBLY...

SECTION 11 INTERMODAL EQUIPMENT

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

MULTI ZERO locking hook for zero barrier threshold systems

2 TONNE TROLLEY JACK

3 TONNE TROLLEY JACK

Low Profile Service Jack Jack Stand Combo

Installation and Operation Manual

Original Operating Manual

Brake System H TX, H2.0TXS [B475]; H TX [B466] Safety Precautions Maintenance and Repair

Rotary feed-through DDF 2

INSTALLATION & OWNER S MANUAL

High-quality WINDOWs & DOOrs

DASMA DASMA

SAFET Y PRODUCTS. TT-Series Safety Edge Product Manual

Model 320 / 320A Hinge Assembly

User manual. Model Mini, Small, Medium and Large

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Model 470 / 470H Coupling

Long Chassis Hydraulic Service Jacks

TPM + Control Techniques UNIDRIVE SP. Quick Startup Guide D Revision: 02

Installation Instructions. Ultimate Screen. English Version 2.3

System Test Report Fitness for Use and Durability

Demonstrate knowledge of electrical theory for Electrical Service Technician B

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

Air Actuated Hydraulic Bottle Jack on Wheels

BELOW-THE-HOOK & MATERIAL HANDLING EQUIPMENT

QUESTION / CLARIFICATION

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

WELMEC External Auxiliary Power Supply of Electrical Energy Meters

Top-of-Pole Mount for 1 Module (TPM1) For Module Types A, B, C, D, E, F, & G ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

LSC SD LANDSCAPE CART ASSEMBLY I NSTRUCTIONS

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

Roto FS Kempton. Window and door technology. Stainless-steel friction stays for outward opening windows

CONTENT. Section. Introduction. Introduction. Hinges. Gears. Corner transmissions/ Middle locks/ Extensions. Stay arms. Additional elements

Rotary-Linear Actuator HSE4 Hydraulic / 100 Bar

REAR SUSPENSION GROUP CONTENTS GENERAL DESCRIPTION TRAILING ARM ASSEMBLY REAR SUSPENSION DIAGNOSIS

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Panther Rhino Tear-Off Machine Instruction Manual

Assembly and Maintenance Manual Type RSBW

EXTRACT of chapter XXXIV coupling devices (version of ) ANNEX XXXIV Requirements on mechanical couplings

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Mounting and Operating Instructions EB 8392 EN. Series 3710 Type 3710 Reversing Amplifier

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Status Date Prepared Reviewed Endorsed Approved

CART-800-D-TS INSTRUCTION MANUAL

Figure 1. Kearney Type HX cutout.

Quarter turn actuator DAPS..R..-F..

ISO INTERNATIONAL STANDARD. Wheelchairs Part 7: Measurement of seating and wheel dimensions

Technical Information

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

White paper: Pneumatics or electrics important criteria when choosing technology

Lecture #8. Design for Manufacturing DfM. ME 2110: Creative Decisions and Design

ISO 5700 INTERNATIONAL STANDARD

Agilent G1554A On-Column Capillary Inlet with EPC

A. This Section includes the following types of sectional overhead doors:

Transcription:

Gütegemeinschaft Schlösser und Beschläge e.v. Guideline: FBDF Translation of ORIGINAL ARTICLE Issue: 2013-04-12 Guideline Casement stoppers for variable turning position of window sashes Casement stoppers that are controlled via the central locking system - definitions and tests Contents 1 Scope of application... 3 2 Definitions... 3 2.1 Casement stopper... 3 2.2 Central locking system... 4 2.3 Movement of the sash... 4 3 Testing... 5 3.1 Testing of the casement stopper / hardware... 5 3.2 Testing of the complete specimen / window... 7 4 Test report... 8 4.1 General... 8 4.2 Tests according to 3.1 (hardware testing)... 9 4.3 Tests according to 3.2 (window testing)... 9 5 Intended use... 9 Published by: Gütegemeinschaft Schlösser und Beschläge e.v. Offerstraße 12 42551 Velbert Phone: +49 (0)2051 / 95 06-0 Fax: +49 (0)2051 / 95 06-20 www: www.beschlagindustrie.de/ggsb/richtlinien.asp Note Technical details and recommendations of this guideline are based on the level of knowledge at hand at the time of printing. The contents of the "Disclaimer" which is present on the aforementioned Internet site shall be governing. Guideline FBDF 1 / 11

Contents 1 Scope of application... 3 2 Definitions... 3 2.1 Casement stopper... 3 2.2 Central locking system... 4 2.3 Movement of the sash... 4 3 Testing... 5 3.1 Testing of the casement stopper / hardware... 5 3.1.1 Specimen... 5 3.1.2 General specifications regarding the test execution... 5 3.1.3 Test sequence 1... 5 3.1.4 Test sequence 2... 6 3.1.5 Test sequence 3... 6 3.2 Testing of the complete specimen / window... 7 3.2.1 Specimen... 7 3.2.2 General specifications regarding the test execution... 7 3.2.3 Test sequence 1... 7 3.2.4 Test sequence 2... 8 4 Test report... 8 4.1 General... 8 4.2 Tests according to 3.1 (hardware testing)... 9 4.3 Tests according to 3.2 (window testing)... 9 5 Intended use... 9 Guideline FBDF 2 / 11

1 Scope of application The guideline at hand contains information and binding instructions for casement stoppers, which are actuated through the window handle and the associated central locking system, and their use in tilt and turn window sashes. It must be applied both by the manufacturer of the casement stoppers (hardware manufacturer) as well as the manufacturer of the window with which it is equipped (manufacturer of windows and doors), and includes: Definitions, tests on the casement stopper, as well as tests on the windows, which are fitted with such casement stoppers. Casement stoppers are used to hold a sash in a defined turning position act against the accidental opening or closing of a window sash offer no protection against the falling out of a window are not fall protections according to the TRAV do not serve as a child protection are not intended for use as an lockable scissor for cleaning purposes are not intended for use as a crush guard are so-called comfort components and thus not safety devices in accordance with item 4.8 of DIN EN 14351-1:2006+A1, and not an opening limiter according to EN 13126-5 2 Definitions 2.1 Casement stopper Braking device, preferably with an extension arm, which is actuated through the window handle and the associated central locking system, and with which a turning window sash can be held open in almost any (variable) intermediate position. They are used to avoid the unintentional opening and closing of (not absolutely plumb-vertically installed) window sashes. To position the sashes in the desired open position, the window handle is moved to a switching position defined by the hardware manufacturer, for example, in the usual "closed position" (0 - window handle is in the vertical position facing downward). 1 Figure 1: Example of a casement stopper 2 3 1 Gear teeth for coupling to the central locking system 2 Extension arm 3 Window frame part (= the linkage point of the extension arm on the window frame) Guideline FBDF 3 / 11

The installation position of the casement stopper is preferably leveled horizontally on the bottom (or the top). Figure 2: Preferred installation position of a casement stopper 2.2 Central locking system Combination of interconnected hardware parts built into the sash, which are actuated through the window handle. 2.3 Movement of the sash For this guideline the following actions shall be understood as a movement of the sash. Movement of the sash is triggered: for example, due to the slippage in the brake device, or because a designated connection point becomes loose (for example, if the extension arm becomes unhinged at its linkage point in the window frame part), or an overload protection becomes loose or breaks. Note: The triggering of an overload protection to protect the casement stopper or bearingpoints (hinge side supporting hardware components) is permitted. After the overload protection triggers or the coupling point is loosened the casement stopper may be dysfunctional. After hinging in the extension arm again, or resetting of the overload protection, the casement stopper must be in a working order again. In case of an overload protection through a fracture (rated break point) a new overload protection must be installed. Movements of the sash due to an elastic deformation of the casement stopper and/or the bearing points and/or their connections do not fall under this definition. Guideline FBDF 4 / 11

3 Testing 3.1 Testing of the casement stopper / hardware 3.1.1 Specimen For a testing of the casement stopper with a static load, it must be installed into a specimen according to the product documentation of the manufacturer, which corresponds to the maximum permitted sash rebate. In this test, the casement stopper is tested and not its sash- and frame-side connection. Therefore, the frame material, the profile design as well as the design of the casement stopper connection can be selected arbitrarily. The bearing points used (hinge side supporting hardware components) can also be selected freely. A separate test must be performed for each casement stopper size. 3.1.2 General specifications regarding the test execution The test is performed for unfavorable opening angles where the greatest forces will occur, due to lever ratios acting on the casement stopper. The induction of the force is performed vertically (± 5 ) relative to the plane of the sash. The load is initially applied in the closing direction, and then in the opening direction of the turning position (pushed closing/pulled opening). The testing is also performed for the end position (open position, maximum turning), provided that the casement stopper is equipped with such a limiter function. 3.1.3 Test sequence 1 On the window handle of the braked window sash of the specimen, a force of 30 N is applied shock-free and increased linearly. After reaching the force of 30 N it will be maintained for 60s (± 5). Then the shock-free release will occur. Criteria for acceptability The casement stopper must be able to absorb a load force of at least 30 N without any movement of the window sash occurring. After the load release, permanent deformations of the casement stopper are permitted, provided the function is not impaired. Through the loading with a force of 30 N, no cracking or breaking may occur on any component which is relevant for the functionality of the casement stopper. Damages to the bearings and their attachments, for example, tears, cracks or permanent deformations are not permitted. Guideline FBDF 5 / 11

3.1.4 Test sequence 2 After conclusion of the test sequence 1, a force will again be applied shock-free to the window handle of the braked window sash of the specimen and linearly increased to max. 100 N. When loaded with forces in the range between > 30 N and 100 N a movement of the sash is permitted to be observed on the window sash. If a movement of the window sash occurs within this range, the force will not be increased any further and a shock-free load release will be executed. If a movement of the window sash does not occur within this range, the force will be increased to a maximum value of 100 N, and a shock-free load release subsequently executed. Criteria for acceptability When loaded with forces in the range between > 30 N and 100 N a movement of the sash is permitted. After the load release, permanent deformations of the casement stopper are permitted, provided the function is not impaired. Through the loading with a force of between > 30 N and 100 N, no cracking or breaking may occur on any component which is relevant for the functionality of the casement stopper (with the exception of the overload protection). Damages to the bearings and their attachments, for example, tears, cracks or permanent deformations are not permitted. 3.1.5 Test sequence 3 This test sequence will only be performed if no movement of the window sash occurred during the test sequence 2. In this case, after conclusion of the test sequence 2, a force will again be applied shock-free to the window handle of the braked window sash of the specimen and linearly increased to max. 200 N. When loaded with forces in the range between > 100 N and 200 N a movement of the sash is permitted to be observed on the window sash. If a movement of the window sash occurs within this range, the force will not be increased any further and a shock-free load release will be executed. If a movement of the window sash does not occur within this range, the force will be increased to a maximum value of 200 N, and a shock-free load release subsequently executed. Criteria for acceptability When loaded with forces in the range between > 100 N and 200 N a movement of the sash is permitted. After a load exposure with a force in the range between > 100 N and 200 N the window sash must continue to be securely supported by the bearing points (hinge side supporting hardware). Cracks or breaks on the casement stopper or attachment thereof are permitted. The functionality of the casementstopper is not required to be provided any longer. Guideline FBDF 6 / 11

3.2 Testing of the complete specimen / window 3.2.1 Specimen For the test with a static load, the casement stopper must be installed into a specimen with the maximum sash rebate width, which is intended by the manufacturer of the windows and doors. The maximum permitted sash rebate width according to the product documentation of the hardware manufacturer must be observed. During this test, the entire specimen will be tested together with the installed casement stopper, in particular their sash and frame-side connection and the interaction with the bearingpoints used. The specimen must therefore be manufactured in such a manner, that it corresponds to the production methods of the manufacturer of windows and doors, and/or the respective system description. The specimen must be selected to represent the respective production method, whereas the most unfavorable production method must be taken into account regarding the force dissipation. A separate test must be performed for each casement stopper size. 3.2.2 General specifications regarding the test execution The test is performed for unfavorable opening angles where, due to the lever ratios, the greatest forces will impact the casement stopper, it's connections as well as the bearing points. The induction of the force is performed vertically (± 5 ) relative to the plane of the sash. The load is initially applied in the closing direction, and then in the opening direction of the turning position (pushed closing/pulled opening). The testing is also performed for the end position (open position, maximum rotation), provided that the casement stopper is equipped with such a limiter function. 3.2.3 Test sequence 1 A force will be applied shock-free to the window handle of the braked window sash of the specimen and linearly increased to max.100 N. When loaded with forces in the range between > 30 N and 100 N a movement of the sash is permitted to be observed. If a movement of the window sash occurs within this range, the force will not be increased any further and a shock-free load release will be executed. If a movement of the window sash does not occur within this range, the force will be increased to a maximum value of 100 N, and a shock-free load release subsequently executed. Criteria for acceptability After the loading with a force of 100 N, no cracking or breaking (with the exception of the overload protection) may occur on any component which is relevant for the functionality of the casement stopper or its attachment points (screw connections). Damages to the bearings and their attachments, for example, tears, cracks or permanent deformations are not permitted. After the load release, the complete specimen must continue to be functional. Guideline FBDF 7 / 11

3.2.4 Test sequence 2 This test sequence will only be performed if no movement of the window sash occurred during the test sequence 1. In this case, after conclusion of the test sequence 1, a force will again be applied shock-free to the window handle of the braked window sash of the specimen and linearly increased to max. 200 N. When loaded with forces in the range between > 100 N and 200 N a movement of the sash is permitted to be observed on the window sash. If a movement of the window sash occurs within this range, the force will not be increased any further and a shock-free load release will be executed. If a movement of the window sash does not occur within this range, the force will be increased to a maximum value of 200 N, and a shock-free load release subsequently executed. Criteria for acceptability When loaded with forces in the range between > 100 N and 200 N a movement of the sash is permitted. After a load exposure with a force in the range between > 100 N and 200 N the window sash must continue to be securely supported by the bearing points (hinge side supporting hardware). After the load release, the complete specimen is not required to be functional anymore. Cracks or breaks on the casement stopper or attachment thereof are permitted. The functionality of the casement stopper is not required to be provided any longer. 4 Test report The test report on the tests according to the guideline at hand must contain the following information: 4.1 General Name and address of the testing laboratory Number, title and date of the guideline at hand Date and decisive identification of the test report Name and address of the applicant Date of the testing Guideline FBDF 8 / 11

4.2 Tests according to 3.1 (hardware testing) Information to uniquely identify the tested casement stopper Detailed description of the tested casement stopper Sash rebate width of the specimen Detailed description of the installation situation of the casement stopper in the specimen Description of the opening angles at which the test sequences were performed Results from the test sequence 1 (3.1.3); for the respective opening angles Results from the test sequence 2 (3.1.4); for the respective opening angles Results from the test sequence 3 (3.1.5); for the respective opening angles 4.3 Tests according to 3.2 (window testing) Information to uniquely identify the tested specimen Detailed description of the tested specimen (Profile geometry, dimensions, material, bearings and their attachment, the casement stopper and its attachments as well as the installation situation) Description of the opening angles at which the test sequences were performed Results from the test sequence 1 (3.2.3); for the respective opening angles Results from the test sequence 2 (3.1.3); for the respective opening angles 5 Intended use The intended use of casement stoppers is the steplessly variable positioning of inward opening window sashs - unless otherwise specified in the product documentation of the hardware manufacturer - of turn-/tilt and turn windows and window doors with a variable turning position for the purpose of brief and intensive airing. The intended use includes the compliance with all the requirements which are contained in the productspecific documents of the hardware manufacturer, for example: Product catalogs, application diagrams (max. sash sizes and weights), hardware installation instructions, operating/maintenance manuals as well as the guidelines VHBH and VHBE of the Gütegemeinschaft Schlösser und Beschläge, and applicable national laws and regulations Guideline FBDF 9 / 11

The following warning applies for manufacturers of windows and doors: WARNING! Danger of injury or death from dropping window sashes in case of an incorrect operation! In case of an incorrect operation (= movement of the window sash which is opened and positioned in the turning direction without first disengaging the casement stopper), very high loads can be transmitted to the bearing points (hinge-side supporting hardware components) and their screw connections, which can ultimately lead to their failure. Therefore: - Attach an operation instruction label (see Figure 3) near the window handle to avoid an incorrect operation. - Check whether the selected combination of window profile, bearing points and their attachment is able to withstand operating errors. For this purpose, test the window sash which is opened and positioned in the turning direction according to item 3.2 of this guideline. Lever/sash position Meaning Do not move the opened and positioned sash! Do not perform any movement (pushed closing/pulled opening) of a window sash which is positioned in the turning direction, without first disengaging the casement stopper. Before performing a movement of the sash, disengage the casement stopper. Before initiating a movement (pushed closing/pulled opening) of the window sash which is opened and positioned in the turning direction, disengage the casement stopper by operating the window handle. After disengaging the casement stopper the window sash may be moved. Only perform a movement of the window sash (pushed closing/pulled opening) after disengaging the casement stopper through an actuation of the window handle. Figure 3: Example of an operation instruction label and explanation of the meaning Guideline FBDF 10 / 11

This guideline was developed in cooperation with: Fachverband Schloss- und Beschlagindustrie e.v. Velbert Offerstraße 12 D-42551 Velbert Testing institute locks and hardware Velbert (PIV) Wallstraße 41 D-42551 Velbert Institut für Fenstertechnik e.v Theodor-Gietl-Straße 7-9 83026 Rosenheim Technical committee of the VFF Verband Fenster und Fassade Walter-Kolb-Straße 1 7 60594 Frankfurt am Main http://www.window.de E-Mail: vff@window.de Guideline FBDF 11 / 11