Instruction Manual. EMF Clean Application Oil Drain Kits

Similar documents
A Issue F. Instruction Manual. EMF3, EMF10 and EMF20 EMF20 Oil Mist Filter

Instruction Manual. EBV Gas Ballast Valves. EBV20 Gas Ballast Valve, 110 V, 50/60 Hz. EBV100S Gas Ballast Valve, 240 V, 50/60 Hz

A Issue F. Instruction Manual. Outlet Mist Filters and Catchpots. MF300AE outlet mist filter

Instruction Manual. RV Pump Cartridge Kits

A Issue C Original. Instruction Manual. XDS5/10 and XDS35i Silencer Kit. Item Number. Description

Instruction Manual. E1M40, E1M80, E2M40 and E2M80 E2M40S and E2M80S Rotary Vacuum Pumps. Item Number

Instruction Manual. E2M28 and E2M30 Rotary Vacuum Pumps

Instruction Manual. E2M175 and E2M275 Rotary Vacuum Pumps. E2M175 Rotary Vacuum Pump, 200 V 50/60 Hz, 380 V 60 Hz, three-phase

Instruction Manual. E2M28 and E2M30 Rotary Vacuum Pumps

WARNING. Before the exhaust silencer is fitted to the pump, the pump must be secured as describe in the pump manual. WARNING

Instruction Manual. E2M28 and E2M30 Rotary Vacuum Pumps A Issue D. Description Item Number

Instruction Manual. E1M18 and E2M18 Rotary Vacuum Pumps. E2M18, 100/200 V, 50 Hz or / V, 60 Hz, single-phase

EH Mechanical Booster Pumps

Instruction Manual. EH Mechanical Booster Pumps. A Issue M

Instruction Manual. QMB Mechanical Booster Pumps A Issue M. QMB1200F Mechanical Booster Pump, 60 Hz

Instruction Manual. E2M0.7 and E2M1.5 Rotary Vacuum Pumps

Instruction Manual. RV3, RV5, RV8 and RV12 Rotary Vane Pumps A 65X-YY-ZZZ. Pump Type Variant Motor Description

D Issue J. Instruction Manual. Active Inverted Magnetron Gauge. Original instructions

Instruction Manual. Description Electrical Supply Item Number

Instruction Manual. Q Series 2 Motor Control Modules - OEM

Instruction Manual. XDS Dry Pump A72X-YY-ZZZ. Pump Variant Motor Description Type X YY ZZZ

Instruction Manual. XDS Dry Pump A72X-YY-ZZZ

Instruction Manual. RV3, RV5, RV8 and RV12 Rotary Vane Pumps A 65X-YY-ZZZ. Pump Type Variant Motor Description X YY ZZZ

Operating Instructions

XDS Scroll Pumps 5. RV Rotary Vane Pumps 20. Small ATEX Certified Pumps 32. Electrical Data 36. Small Pump Accessories 36. E-LAB Rotary Pumps 41

Instruction Manual. GV Dry Vacuum Pumps

Two Stage Rotary Vane Vacuum Pumps Operation and Maintenance Manual

Instruction Manual. QDP Drystar Vacuum Pumps A Issue P. QDP80 Drystar Pump (8 kw)

Instruction Manual. XDS Dry Pump. Description Electrical Supply Item Number

T-STATION 85 INSTRUCTION MANUAL. Publication Number: D Issue: A Original Instructions. edwardsvacuum.com

Instruction Manual. XDS Dry Pump A72X-YY-ZZZ

Instruction Manual. AUTO 306 accessories: EB3 Multihearth Electron Beam Source and accessories. Volume 1 - Installation and Maintenance Instructions

Instruction Manual. XDS Dry Pump. Description Electrical Supply Item Number

Instruction Manual. S Issue E Original. 6 Inch MSeal Booster Pumps and Process Isolation Booster Pumps

Betriebsanleitung Operating Instructions. Oil Mist Filter

Instruction Manual. XDS Dry Pump. A Issue F Original

nxds DRY SCROLL PUMP THE ULTIMATE DRY CHOICE

Vacuum Pumps. Rotary Pumps F12 F13 F14 F15 F16 F17 F18 F19 F20 F21 F22 F23 F24

SV HIGH VACUUM (Positive Relief) SEAL-OFF VALVE 1 Inch Size

Instruction Manual. 149-H/149-HS/212-J/412-J Microvac Pumps

Instruction Manual. 212-J/412-J Microvac Pumps

EM OIL SEALED ROTARY PUMPS APPLICATION AND ACCESSORY INFORMATION EM ROTARY PUMPS BROAD APPLICATION COVERAGE

Eurovacuum Installations and Operating manual EV Series Vacuum pumps Models

Operating Instructions

Towed Vehicle Lube Pump and Plumbing Installation Instructions

MOTOR DATA. Air Air Lubricator Motor Inlet Consumption Drops Per Size Size (cfm) Minute*

MEDIUM AND LARGE WET PUMPS MAXIMISE YOUR PRODUCTIVITY AND PERFORMANCE

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

View our inventory. Instruction Manual. IPUP E100 (v2.1) Description Electrical supply BOC Edward s Applied Material s

Instruction Manual. ESDP12 and ESDP30 Scroll Pumps. Item Number. Description

[Small diaphragm vacuum pumps]

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

Instruction Manual. EXT Split Flow Compound Turbomolecular Pumps. EXT200/200H LCMS (Reversed Body)

Index. LIST No. GENERAL INFORMATION 1/01, 1/02. General Information 1/03. Selection of Valve Types VALVE TYPE FL 441 (STANDARD PRESSURE SERIES) 2/01

Owner's Manual. Remote Switch: Outdoor agricultural sprayer kit used to remotely turn On/Off the boom. Read this manual.

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

Operation Manual BOTTLE TOP DISPENSER

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

SW14.5TI INTEGRAL HYDRAULIC FLANGE SPREADING WEDGE. Repair Manual INNOVATION IN ITS MOST FUNCTIONAL FORM

Liquid ring vacuum pumps in compact design

Towed Vehicle Lube Pump and Plumbing Installation Instructions

Instruction manual & spare parts lists for models TRP-6 to TRP-90

Automotive Air Conditioning Manifold Gauge Sets

Installation instruction do88 Performance Radiator for Volvo S60 V70 XC70 S

shop online:

JADE Bottle Top Dispenser

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

C02 SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

Instruction Manual. EPX HiVac Series Dry Vacuum Pumps. Description EPX EPX TWIN

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

ALLDATA Online Land Rover Freelander (LN) V6-2.5L - Camshaft Timing Belt

Liquid ring vacuum pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

Instruction Manual for Direct-Drive Oil Sealed Rotary Vacuum Pump

With regards to safety it is not necessary to check for correct operation.

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Breathing and air bleed filter, water-absorbing. Type BFSK. Contents. Features. RE Edition: Replaces: 51412

Assembly instructions

Towed Vehicle Lube Pump and Plumbing Installation Instructions

CHAPTER 9 : TYPE II TEST ON SI ENGINES (VERIFYING CARBON MONOXIDE EMISSION AT IDLING)

Maintenance Manual. 3-Inch Internal Valve. F660 Series

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Maintenance Manual 3-INCH INTERNAL VALVE F660 SERIES

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

P5510. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Scientific vapor pumps

Differential Pressure Switch QBM81-

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation and Operating Manual

Installation. Installation. 12. System Diagram... 10

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

A Issue C Original. Instruction Manual. if1800 Rapid Loadlock Dry Pumping Systems. View our inventory

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

Fuel Tank and Lines Fuel Delivery System Component Location Item Part Number Description

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve

Differential Pressure Switch QBM81-

Transcription:

Instruction Manual A504-19-880 Issue D Original EMF Clean Application Oil Drain Kits Description EMF Clean Application Oil Drain Kit for RV3 to RV12, Speedivac 2 and E2M0.7 to E2M12 pumps EMF/MF30 Clean Application Oil Drain Kit for E1/E2M18, E2M28 and E2M30 pumps Item Number A504-19-000 A504-20-000

This page has been intentionally left blank.

D372-80-880 Issue B Contents Section Page 1 Introduction... 1 Contents 1.1 Scope and definitions... 1 1.2 Description... 1 2 Installation... 3 2.1 Unpack and Inspect... 3 2.2 Fit the EMF Oil Drain Kit to RV3 to RV12 pumps... 4 2.3 Fit the EMF Oil Drain Kit to Speedivac 2 to E2M12 pumps... 6 2.4 Fit the EMF/MF30 Oil Drain Kit to E1/E2M18, E2M28 and E2M30 pumps... 8 3 Storage and disposal... 11 3.1 Storage...11 3.2 Disposal... 11 For return of equipment, complete the HS Forms at the end of this manual. Illustrations Figure Page 1 Fit the EMF Oil Drain Kit to RV3 to RV12 pumps... 5 2 Fit the EMF Oil Drain Kit to Speedivac 2 to E2M12 pumps... 7 3 Fit the gas ballast and hose adaptors to the E1/E2M18, E2M28 and E2M30 pumps... 8 4 Fit the EMF/MF30 Oil Drain Kit to E1/E2M18, E2M28 and E2M30 pumps... 9 Tables Table Page 1 EMF Oil Drain Kit component checklist... 3 2 EMF/MF30 Oil Drain Kit component checklist... 3 Ipsitech 9000(C)-2008 Edwards Limited 2008. All rights reserved. Page i

D372-80-880 Issue B This page has been intentionally left blank. Page ii Edwards Limited 2008. All rights reserved.

1 Introduction 1.1 Scope and definitions This manual provides installation, operation and maintenance instructions for the Edwards Clean Application Oil Drain Kits (abbreviated to Oil Drain Kit in the remainder of this manual). You must use the Oil Drain Kits as specified in this manual. Introduction Read this manual before you install and operate the Oil Drain Kit. Important safety information is highlighted as WARNING instructions; you must obey these instructions. The use of WARNINGS is defined below. The units used throughout this manual conform to the SI international system of units of measurement. 1.2 Description WARNING Warnings are given where failure to observe the instruction could result in injury or death to people. Notes: 1. In normal operation, the oil-level will be at or below the level of the drain adaptor on the oil mist filter. 2. When you fit a new oil mist filter, or when you fit a new mist filter element to the oil mist filter, the oil-level in the pump will fall as the oil saturates the mist filter element and fills trapped volumes in the oil mist filter. When fitted, the Oil Drain Kit returns oil trapped in the oil mist filter to the pump, through the gas ballast port. This reduces oil loss from the pump and minimises the need to check the pump oil-level and to refill the pump with oil. On a system in which the pump operates continuously, oil will only return to the pump when the pump inlet pressure is below approximately 4 x 10 4 Pa, 400 mbar. You will therefore need to check the oil level in the pump more frequently if the pump inlet pressure is above this pressure for a long time. You can only use the Oil Drain Kit if the gases pumped do not contaminate the oil. The EMF/MF30 Oil Drain Kit (for the E1/E2M18, E2M28 and E2M30 pumps) is not suitable for use in processes in which sodium azides are pumped. On RV3 to RV12 and Speedivac 2 to E2M12 pumps, the Oil Drain Kit is fitted in place of the gas ballast control. When the Oil Drain Kit is fitted: WARNING Do not use the Oil Drain Kit if you use the pump in processes in which condensible vapours or sodium azides are pumped. On all pumps except the RV3 to RV12 pumps, the pump will vent to atmosphere when it is switched off. On the E1/E2M18, E2M28 and E2M30 pumps, oil will only be returned to the pump when the gas ballast control is open. Edwards Limited 2008. All rights reserved. Page 1

This page has been intentionally left blank. Page 2 Edwards Limited 2008. All rights reserved.

2 Installation 2.1 Unpack and Inspect Remove all packing materials and protective covers and check the Oil Drain Kit. If the Oil Drain Kit is damaged, notify your supplier and the carrier in writing within three days; state the Item Number of the Oil Drain Kit together with your order number and your supplier's invoice number. Do not use the Oil Drain Kit if it is damaged. Installation Check that your package contains the items listed in Table 1 or 2. If any item is missing, notify your supplier in writing within three days. If the Oil Drain Kit is not to be used immediately, replace the protective covers and store it in suitable conditions as described in Section 3.1. Table 1 - EMF Oil Drain Kit component checklist Quantity Description Check ( ) 1 Gas ballast adaptor 1 Bonded seal 1 Drain adaptor 1 Restrictor: 0.8 mm hole 1 Nozzle 1 Flexible oil-return tube 2 Hose clips Table 2 - EMF/MF30 Oil Drain Kit component checklist Quantity Description Check ( ) 1 Gas ballast adaptor: 1 / 4 inch BSP 1 'O' ring 2 Bonded seals 1 Banjo bolt 1 Hose adaptor 1 Drain adaptor 1 Restrictor: 0.8 mm hole 1 Flexible oil-return tube 2 Hose clips Edwards Limited 2008. All rights reserved. Page 3

Installation 2.2 Fit the EMF Oil Drain Kit to RV3 to RV12 pumps Refer to Figure 1 in the following procedure. Where necessary, refer to the instruction manuals supplied with your pump and oil mist filter when you fit the Oil Drain Kit. 1. Switch off the pump. Remove the drain-plug from the oil mist filter and drain the oil from the oil mist filter. Remove the bonded seal and retain the drain-plug for future use. 2. Use the bonded seal removed in Step 1 and fit the drain adaptor (6) to the oil mist filter (4). 3. Turn the gas ballast control to the high flow position (position II). Push the control down (against the spring), turn the control anticlockwise to release it and remove the control from the pump. Leave the spring in position in the gas ballast inlet. 4. Use the bonded seal supplied to fit the nozzle (1) to the gas ballast adaptor (8). 5. Fit the gas ballast adaptor (8) to the gas ballast inlet on the pump. Press the adaptor down (against the spring) and turn it clockwise until the flats on the gas ballast adaptor are in line with the gas ballast '0' position marked on the top of the pump. 6. Cut a suitable length from the flexible oil-return tube. The routing of the tube (7) must be approximately as shown in Figure 1. When fitted, the tube must not be taut and there must be no tight bends in the tube. Ensure that the ends of the oil-return tube are free of burrs and that they are squarely cut (that is, the cut faces are at a right-angle to the length of the tube). 7. Fit the restrictor (3) into one end of the tube as shown in Figure 1. 8. Fit the tube (7) to the drain adaptor (6) on the oil mist filter and to the nozzle (1) on the gas ballast adaptor (8). 9. Use the hose clips (2) to secure the ends of the flexible oil return tube (7). Page 4 Edwards Limited 2008. All rights reserved.

Figure 1 - Fit the EMF Oil Drain Kit to RV3 to RV12 pumps Installation 1. Nozzle 2. Hose clips 3. Restrictor 4. EMF Oil mist filter 5. Pump 6. Drain adaptor 7. Flexible oil-return tube 8. Gas ballast adaptor Edwards Limited 2008. All rights reserved. Page 5

Installation 2.3 Fit the EMF Oil Drain Kit to Speedivac 2 to E2M12 pumps Refer to Figure 2 in the following procedure. Where necessary, refer to the instruction manuals supplied with your pump and oil mist filter when you fit the Oil Drain Kit. 1. Switch off the pump. Remove the drain-plug from the oil mist filter and drain the oil from the oil mist filter. Remove the bonded seal and retain the drain-plug for future use. 2. Use the bonded seal removed in Step 1 to fit the drain adaptor (6) to the oil mist filter (4). 3. Unscrew the gas ballast control and remove it from the gas ballast inlet on the pump. Remove the 'O' ring from the control and retain the control for future use. Remove the spring (or plunger on Speedivac 2 pumps) from the gas ballast inlet. Retain the spring (or plunger) for future use. 4. Use the 'O' ring removed in Step 3 and fit the nozzle (7) to the gas ballast inlet on the pump. 5. Cut a suitable length from the flexible oil-return tube. The routing of the tube (3) must be approximately as shown in Figure 2. When fitted, the tube must not be taut and there must be no tight bends in the tube. Ensure that the ends of the oil-return tube are free of burrs and that they are squarely cut (that is, the cut faces are at a right-angle to the length of the tube). 6. Fit the restrictor (2) into one end of the tube as shown in Figure 2. 7. Fit the tube (3) to the drain adaptor (6) on the oil mist filter and to the nozzle (7) on the gas ballast inlet on the pump. 8. Use the hose clips (1) to secure the ends of the flexible oil return tube (3). Page 6 Edwards Limited 2008. All rights reserved.

Figure 2 - Fit the EMF Oil Drain Kit to Speedivac 2 to E2M12 pumps Installation 1. Hose clips 2. Restrictor 3. Flexible oil-return tube 4. EMF Oil mist filter 5. Pump 6. Drain adaptor 7. Nozzle Edwards Limited 2008. All rights reserved. Page 7

Installation 2.4 Fit the EMF/MF30 Oil Drain Kit to E1/E2M18, E2M28 and E2M30 pumps Where necessary, refer to the instruction manuals supplied with your pump and oil mist filter when you fit the Oil Drain Kit. 1. Switch off the pump. Remove the drain-plug from the oil mist filter and drain the oil from the oil mist filter. Remove the bonded seal and retain the drain-plug for future use. 2. Refer to Figure 4. Use the bonded seal removed in Step 1 and fit the drain adaptor (5) to the oil mist filter (7). 3. Refer to Figure 3. Remove the circlip (4), wire mesh (3) and filters (2) from the gas ballast inlet on the pump; retain these for future use. 4. Fit the gas ballast adaptor (6) and 'O' ring (5) to the gas ballast inlet port on the pump, then use the banjo bolt (10) and the two bonded seals (7, 9) to fit the hose adaptor (8) to the gas ballast adaptor (6). 5. Refer to Figure 4. Cut a suitable length from the flexible oil-return tube. The routing of the tube (4) must be approximately as shown in Figure 4 and when fitted, the tube must not be taut and there must be no tight bends in the tube. Ensure that the ends of the oil-return tube are free of burrs and that they are squarely cut (that is, the cut faces are at a right-angle to the length of the tube). 6. Fit the restrictor (3) into one end of the tube as shown in Figure 4. 7. Fit the tube (4) to the drain adaptor (5) on the oil mist filter and to the hose adaptor (2). 8. Use the hose clips (1) to secure the ends of the flexible oil return tube (4). 9. Open the gas ballast control. Figure 3 - Fit the gas ballast and hose adaptors to the E1/E2M18, E2M28 and E2M30 pumps 1. E1/E2M pump 2. Filters 3. Wire mesh 4. Circlip 5. 'O' ring 6. Gas ballast adaptor 7. Bonded seal 8. Hose adaptor 9. Bonded seal 10. Banjo bolt Page 8 Edwards Limited 2008. All rights reserved.

Figure 4 - Fit the EMF/MF30 Oil Drain Kit to E1/E2M18, E2M28 and E2M30 pumps Installation 1. Hose clips 2. Hose adaptor 3. Restrictor 4. Flexible oil-return tube 5. Drain adaptor 6. Pump 7. Oil mist filter A. E1/E2M18 pump with EMF20 B. E2M28 and E2M30 pump with MF30 Edwards Limited 2008. All rights reserved. Page 9

This page has been intentionally left blank. Page 10 Edwards Limited 2008. All rights reserved.

3 Storage and disposal 3.1 Storage Store the Oil Drain Kit in cool, dry conditions until required for use. When required, install the Oil Drain Kit as described in Section 2. 3.2 Disposal Dispose of pump oil, the Oil Drain Kit and any components removed from it safely in accordance with all local and national safety and environmental requirements. Storage and disposal Edwards Limited 2008. All rights reserved. Page 11

This page has been intentionally left blank. Page 12 Edwards Limited 2008. All rights reserved.