Battery Powered Air Samplers Manufactured by F&J SPECIALTY PRODUCTS, INC.

Similar documents
BATTERY BANK POWERED AC/DC AIR SAMPLERS

BATTERY BANK POWERED AC/DC AIR SAMPLERS

Portable Digital Flow Meter High Volume Air Samplers

Portable Digital Flow Meter High Volume Air Samplers

F&J SPECIALTY PRODUCTS, INC.

Digital High Volume Ambient Air Monitoring Systems 110 Volt

Analog Low Volume Air Samplers

ESCORT ELF and ESCORT LC SAMPLING PUMPS

ISO-9001:2008 HOT PLATES CATALOG. Phone: Fax: Web:

Power Guide. TimeMate /OPEN OK 2.78 ToGo 001:45: Flexible and reliable power system

HI-Q. Filter Media For Air Sampling. Filter Paper for Air Sampling. Glass Fiber, Ashless Cellulose, & Carbon Impregnated Filter Paper

mass flowmeter for compressed air

Miniature Pneumatic Solenoid Valve. Power: 0.5 Watt & 1.0 Watt. Not all power options are available in all models, see ordering info.

Buck BioAire Model B520 Instruction Manual

VAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm)

Buck BioSlide Model B1020 Instruction Manual

Battery Fuel Gauge Specification

i-stat 1 Analyzer 2 Before You Use the Analyzer

The New Filter Valve Technology

COUNTER CLOCKWISE FOR CLARITY (SEE MANUAL FOR SPECIFIC WATER & DUST TIGHT AP LOCAL ELEMENT ENCLOSURE ROTA FLAT PARALLEL TO FLOW.

INSTRUCTION MANUAL CAT Bio-Pump Plus

Dimensional Drawing - Mounting Options

8000 Series Liquid Flow Meter

Battery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4)

PORTER FLOWMETERS & FLOW CONTROLLERS. Technology you can trust

Jerome DOSIMETER POCKET PUMP OPERATOR S MANUAL

Installation, Operation & Maintenance Manual

Miniature Multimedia Valves

8000 Series Liquid Flow Meters

Operating Instruction for Flowmonitor. Model: DF-WM

SN1010 NATURAL VENTILATION CONTROLLER SET POINT

RCM - Direct Reading Flowmeters

iration strikes. CYCLONE BATTERY PACK User s Manual

MOUNTING BRACKETS. Dimensional Drawing - Mounting Options


PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

G2 Industrial Grade Meters

For the Health Physics, Environmental & Nuclear Industries

Precision Control Devices

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

VSO Thermally Compensated Proportional Valve

Power Conversion. Battery Chargers. Model

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

Crime-lite 2. a new and improved range of forensic light sources

LFC Integrated Flow Control Module. Description Malema Sensors

KDM ARMORED FLOW METER & SWITCH

King Instrument Company opened its doors in 1983 with one major goal:

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Top quality For industrial use

Pro Xpc. Auto. Automatic Electrostatic Air Spray Guns

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

Sealed Lead-Acid Batteries

WalkLAB Digital Dissolved Oxygen meter HD9030

TIF VA500A DIGITAL HVAC ANALYZER

Thermo Scientific Gilmont

AccuPower AQU126B Installation Instructions

EL5600 Series Electric Actuators for DN15 to DN100 Valves

Battery Booster Pack. Instruction Manual for P/N

Miniature Proportional Valve. Non-Thermally Compensated Proportional Valve

ATEX II 2G Ex ib IIC T4 Gb. ATEX II 2D Ex ib IIIC T150 C Db ATEXBEAM

AccuPower AQU128B Installation Instructions

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

ROCKER 300 VACUUM PUMP INSTRUCTION MANUAL

Welcome to your new. HOURCAR experience! Glossary of Terms. This technology goes into service on. August 6, 2015.

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

DK Series Pneumatic Diaphragm Valves Product Data Sheet

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

For the Environmental Scientist & Health Physicist

Most popular of all chain machines, the lightweight Mini Chain

Hi Lumens & Green Energy

8-Unit Case Package Contents

OPERATING MANUAL. June 2003

Model Model Model

Fuel Transfer Pumps DC Aluminum Gear Fuel Pump with Auto Nozzle

KAM E-IAS ELECTRIC ISOKINETIC AUTOMATIC SAMPLER

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

12AT/50AT Series Spin-On Filters

Battery Boxes Series 8316

Conductivity Sensors. Applications. 140 Series Conductivity Sensors Product Data Sheet LIQ_PDS_140_141_142_Conductivity_Sensors January 2014

AMETEK Model PPC Series Electronic Pressure Calibrator

Power Beam 20MCP Searchlight with 12 LED Area Light and Vehicle Jump Starter. Instruction Manual

ESCORT LC Pump. Instruction Manual WARNING

Universal Sample Pump

Power Conversion. Battery Chargers. Model

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

Emergency Power. Are you prepared? Rev 2.0

Sealed Lead-Acid Batteries

KL1.4LM (A) Main characteristic:kl1.4lm (A) LED mining lamp

International Edition. The Professionals Choice for Air Sampling Equipment

FLOW CONTROLLERS Instrument/Analyzer Products. Catalog 4513/USA April 2003

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

The mobility, integration & power to help improve patient care.

Transcription:

Battery Powered Air Samplers Manufactured by Lightweight Long lasting On-Board NiMH Batteries Operable from three modes of power input F&J Digital Flowmeter Technology Rev.: 08 Dec. 2016

EMERGENCY RESPONSE SAMPLING SYSTEM 12VDC POWERED AIR SAMPLER Digital Flowmeter Technology F&J Model DF-40L-8 NOTABLE FEATURES: State-of-the-Art Electronics Operating Modes Line Power (100VAC to 250VAC) On-Board Batteries Automobile Cigarette Lighter Long-lasting Nickel Metal Hydride Batteries Battery Charging Circuit operable from Line Power Input Lightweight ~9 lbs. (4 kg) Maximum Flow ~35 LPM Maximum; typical Bright LED Display Automatic Flow Control Feature Flowrate and Volume totalizations displayed are corrected to a factory settable Reference Temperature and Pressure (4 options available) Auto Shut-off on time or volume Battery Life Indicator GENERAL DESCRIPTION: F&J Model DF-40L-8 is a lightweight, small footprint, DC voltage powered air sampling system operable from (1) on-board 4500 mah NiMH batteries, (2) line power, or (3) automobile cigarette lighter socket. The DF-40L-8 is well suited for emergency response sampling activities where users do not know whether line power will be available. Typical operating time from on-board batteries is approximately 6 hours utilizing 47 mm glass fiber filter paper. The automatic flow control feature with the F&J Digital Flowmeter technology provides maximum flexibility for emergency response sampling responsibilities. The set flowrate is maintained automatically in case of dust loading and does not require operator attention. Typical flow range is 10-35 SLPM (0.3-1.2 SCFM).

DF-40L-8 Battery Powered Air Sampler Specifications Pump Type: Dual diaphragm high efficiency Maximum Flowrate: Typical 35 LPM with 47 mm glass fiber media (98%DOP efficiency) Power Source: Internal 12VDC Battery Pack NiMH; 12VDC/4500 mah External Line Power; 100VAC to 250VAC Automobile Cigarette Lighter 12VDC Battery Charging System: Internal System which charges from line power Operating Time on Batteries: ~ 6 hours with FP47M glass fiber paper Current Draw: 0.6 A maximum Filter Holder Fitting: 3/8 FNPT quick disconnect Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICULATE PAPER DIAMETER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF SCMH / SCM Digital Flowmeter Keypad/Display Handle: Weight: Durable metal 9 lbs. (4 kg) Dimensions: 8 6 8 (20 15 20 cm) Operating Temperature: 0ºF to 122ºF (-18ºC to 50ºC) Display: Bright LED (6 character, 1,2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 10-35 LPM Flow Accuracy: ± 4% of Full Scale Factory Settable Reference T and P Classical STP 0ºC, 760 mmhg Normal T and P 20ºC, 760 mmhg Modified Normal T and P 70ºF, 760 mmhg Standard Ambient T and P 25ºC, 760 mmhg OPTIONS: Data Storage Device (P/N: 232FCDSD) 2 GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20) Flow / Volume: SLPM/SL 28.5

EMERGENCY RESPONSE SAMPLING SYSTEM 12VDC POWERED AIR SAMPLER Digital Flowmeter Technology F&J Model DF-40L-12 NOTABLE FEATURES: State-of-the-Art Electronics Operating Modes Line Power (100VAC to 250VAC) On-Board Batteries Automobile Cigarette Lighter Long-lasting Lead Acid Battery Battery Charging Circuit operable from Line Power Input Lightweight ~17 lbs. (7,7 kg) Maximum Flow ~35 LPM Maximum; typical Bright LED Display Automatic Flow Control Feature Flowrate and Volume totalizations displayed are corrected to a factory settable Reference Temperature and Pressure (4 options available) Auto shut-off on time or volume Battery Life Indicator GENERAL DESCRIPTION: F&J Model DF-40L-12 is a lightweight, small footprint, DC voltage powered air sampling system operable from (1) on-board 12VDC; 12Ah lead acid battery, (2) line power, or (3) automobile cigarette lighter socket. The DF-40L-12 is well suited for emergency response sampling activities where users do not know whether line power will be available. Typical operating time from on-board battery is approximately 12 hours utilizing 47mm glass fiber filter paper. The automatic flow control feature with the F&J Digital Flowmeter technology provides maximum flexibility for emergency response sampling responsibilities. The set flowrate is maintained automatically in case of dust loading and does not require operator attention. Typical flow range is 10-35 SLPM (0.3-1.2 SCFM).

DF-40L-12 Battery Powered Air Sampler Specifications Pump Type: Dual diaphragm high efficiency Maximum Flowrate: Typical 35 LPM with 47 mm glass fiber media Power Source: Internal 12VDC Battery Pack Lead Acid; 12VDC/12Ah External Line Power; 100VAC to 250VAC Automobile Cigarette Lighter 12VDC Battery Charging System: Internal System which charges from line power Operating Time on Batteries: ~ 12 hours Current Draw: 0.6 A maximum Filter Holder Fitting: 3/8 FNPT quick disconnect Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICULATE PAPER DIAMETER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF SCMH / SCM Digital Flowmeter Keypad/Display Handle: Weight: Durable metal 17 lbs. (7,7 kg) Dimensions: 8 9 12 (20 23 30 cm) Display: Bright LED (6 character; 1,2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 10-35 LPM Flow Accuracy: ± 4% of Full Scale Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM OPTIONS: Data Storage Device (P/N: 232FCDSD) 2 GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20) Flow /Volume: SLPM/SL 28.5 Rev.: 08 Dec. 2016

EMERGENCY RESPONSE SAMPLING SYSTEM Digital Flowmeter Technology F&J Model DF-AB-40L NOTABLE FEATURES: State-of-the-Art Electronics Operating Modes Line Power (100VAC to 250VAC) On-Board Batteries Automobile Cigarette Lighter Long-lasting Nickel Metal Hydride Batteries Battery Charging Circuit operable from Line Power Input Lightweight ~13 lbs. (5,9 kg) Maximum Flow 30 to 35 LPM Maximum; typical Bright LED Display Automatic Flow Control Feature Flowrate and Volume totalizations displayed are corrected to a factory settable Reference Temperature and Pressure (4 options available) Auto shut-off on time or volume Battery Life Indicator GENERAL DESCRIPTION: F&J Model DF-AB-40L is a lightweight, small footprint, DC voltage powered air sampling system operable from (1) on-board 4500 mah NiMH batteries, (2) line power, or (3) vehicle cigarette lighter socket. The DF-AB-40L is well suited for emergency response sampling activities where users do not know whether line power will be available. Typical operating time from on-board batteries approximately 6 hours utilizing 47 mm glass fiber filter paper. The automatic flow control feature with the F&J Digital Flowmeter technology provides maximum flexibility for emergency response sampling responsibilities. The set flowrate is maintained automatically in case of dust loading and does not require operator attention. The air sampler is contained in a lightweight small dimensioned enclosure which is water tight. The unit can be carried very easily by its large, rugged plastic handle. Typical flow range is 10-35 SLPM (0.3-1.24 SCFM).

DF-AB-40L Battery Powered Air Sampler Specifications Pump Type: Dual diaphragm high efficiency Maximum Flowrate: 35 LPM typical with 47 mm glass fiber media Power Source: Internal 12VDC Battery Pack NiMH; 12VDC/4500 mah External Line Power; 100VAC to 250VAC Vehicle Cigarette Lighter 12VDC Battery Charging System: Internal System which charges from line power Operating Time on Batteries: Current Draw: 0.6 A maximum ~ 6 hours Filter Holder Fitting: 3/8 FNPT quick disconnect Standard Combination Filter Holders Available: FILTER HOLDER MODEL CHARCOAL CARTRIDGE DIMENSIONS PARTICULATE PAPER DIAMETER FJ-05P F&J Model B 2 or 50 mm FJ-21P F&J Model C 2 or 50 mm FJ-35P F&J Model B 47 mm FJ-46P F&J Model C 47 mm FJ-51P F&J Model M 2 or 50 mm FJ-53P F&J Model M 47 mm Available Engineering Units for Flow and Volume: sccm / scc SLPM / SLP SCFM / SCF SCMH / SCM Digital Flowmeter Keypad/Display Handle: Weight: Durable plastic 13 lbs. (5,9 kg) Dimensions: 14.5 L 8 W 10 H (36,8 20,3 25,4 cm) Display: Bright LED (6 character, 1,2 cm H) Elapsed Time: DD:HH:MM up to 168 hours Flow Control: Adjustable from keypad between 10-35 LPM Flow Accuracy: ± 4% of Full Scale Flow / Volume: SLPM/SL 28.5 Factory Settable Reference T and P Classical STP 0ºC, 1 ATM Normal T and P 20ºC, 1 ATM Modified Normal T and P 70ºF, 1 ATM Standard Ambient T and P 25ºC, 1 ATM OPTIONS: Data Storage Device (P/N: 232FCDSD) 2 GB Secure Digital Card (P/N: 372239) Flash card Reader (P/N: SDDR-199-A20)

Front View Cord Storage Cigarette Lighter Cord stores in Compartment accessible from outside. Side View View of Inside Air Sampler on window bracket Connection to vehicle cigarette lighter for 12VDC or sampling applications