Transformer Disconnects

Similar documents
NEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Spec-Tech Industrial Electric

Transformer Disconnects

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Industrial Control Transformers

Transformers 6. Gross Automation (877)

General Purpose Buck - Boost Wiring Diagrams... 86

Engineered solutions for power and the environment

HPS Fusion General Purpose Enclosed Transformer

Industrial Control Power Transformers Class MT

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Engineered solutions for power and the environment

Selection Guide. Control Circuit and Load Protection

2 SLR Series Line Reactors... 50

Industrial Control Power Transformers

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Medium Voltage Metal-Enclosed Switches

Industrial Control Transformers

HPS Fusion General Purpose Enclosed Transformer

Tanning Bed Transformers

Industrial Control Transformers

Dry-Type Transformers Mini-Power Centers

Control Circuit Protection

HPS Spartan Industrial Open Core & Coil Control Transformer

Totally Enclosed Non-Ventilated

Jim Baker President, Electro-Matic Products, Inc.

Midwest Dry Type Transformers

Single-Phase Ventilated

Three Phase Transformers

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

Medium Voltage Metal-Enclosed Switches

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Three-Phase Ventilated

Generator Fire Safety: Generator assemblies should be located outside the building.

These documents contain additional information concerning related products from Rockwell Automation.

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

TA Ta VA CTRL-XFRMR

Non-Ventilated Automation Transformers 6

Quik-Spec Electrical Gear

PH250MQMJ CNTL 250VA 240X X240

OTEC Transfer switch open transition

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Bussmann series Quik-Spec Coordination Panelboard

Industrial Control Transformers

3. Coils shall be of molded construction

SECTION VARIABLE FREQUENCY DRIVE UNITS

Machine Tool Industrial Control Transformers

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Lighting and Power Distribution Panelboards

PowerPact B. Molded case circuit breakers and switches from A

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Effective December 2015 Supersedes September 2013

50 Series. Features. Suffix Suffix Series Voltage Combinations

Dry Type Distribution Transformers

Efficiency is in our DNA

Dry Type Distribution Transformers

Product Selection 3-Pole Contactors

Control Circuit Transformers

Transfer switch OTEC and OTECSE open transition

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers

ACCESSORIES Electric Heater Compact Cooling Fans Floor Stand Kit PANELITE Enclosure Lights BULLETIN: A28SX

C E R T I F I C A T E O F C O M P L I A N C E

C1000 Series Automatic Cap Bank

Miscellaneous. Unit Substation 600 Volts and Below. Sealed Mini Power-Zone Transformers Industrial Control

Application Description

Enclosures. See Section Typical Description

LED Auxiliary Devices

Compact Circuit Protector (CCP)

Three-phase isolating transformers for photovoltaic and wind-power systems

Use the following standards for system design and performance requirements.

SECTION PANELBOARDS

Low Voltage Lighting Power Supplies

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers

Solid-State Relays. Solid-State Relays. Features. Description. Overview

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

Dry Type Distribution Transformers

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Rotary Cam Switches. Rotary Cam Switches

CPT Series Control Transformers

Solid-State Relays. Solid-State Relays. Features. Description. Overview

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Max. Input Power (W) Inrush Current (A pk /µs)

Quik-Spec. Section Contents

Compact Circuit Protector (CCP)

Company Overview. Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances

Products :: Circuit Protection :: Thermal Circuit Breakers

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Preferred Cutout, Disconnect Enclosure, Type 12

Contactors & Starters Index

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

9070T150D1 Industrial Control Transformer, 150VA

Features, Benefits and Functions

Transcription:

Disconnects For Control Panel Lighting and Auxillary Power UL and CUL Listed TÜV Rheinland Licensed CE Marked Series

Electric Manufacturing Company

Table of Contents TDLK Series NEMA 1-12... 3-4 TDEK Series NEMA 1-12... 5-6 TDAK Series NEMA 1-12... 7-8 Auxiliary Power TLAK Series NEMA 1-12...9-10 Dual Secondary ADLK Series NEMA 1-12...11-12 TDGK12 Giant Series NEMA 12... 13 TM Series Compact Style...14-15 TDFM12 Series Slimline... 16 Description Red on Pilot Light Green on Pilot Light Duplex Receptacle (NEMA 1) Gasketed Duplex Receptacle GFI Receptacle Ground Fault Lights Delete Feature Provides Suffix R G D C F Z X 1.800.428.2626 www.dongan.com 1

Disconnect Electric Manufacturing Company is pleased to display its new line of Lighting Disconnects. The products in this catalog represent the most advanced series of disconnects available in the market today. Most important, these products have the approvals and certifications needed to compete and ship virtually worldwide. All Disconnects are UL Listed and Canadian UL Listed. UL File E185781. In addition, all series, except Series TDG12, ADLK, and ADLK12, are CE Marked and Licensed for the European Union T Mark under the EN60204-6/30-06 Safety of Machinery Standard. These Disconnects have undergone extensive testing and certification by TÜV Rheinland and Underwriters Labs. With Disconnects, approvals are built in - not a high cost option. Disconnects are manufactured in 11 distinct series with features to meet all your transformer lighting disconnect needs: NEMA 1/IP23 and NEMA 12/IP54/IP65 enclosure styles. Domestic and multitap European voltage combinations. Finger - Safe fuses and transformer terminals. CE Marked, TÜV Bauart Marked, copper wound transformers. European and domestic color coded labels and switches. Disconnects comply with automotive specifications. Extensive third party approvals provide great flexibility in design variation. Contact your distributor, your Representative or the factory if the voltage combination, or configuration needed is not shown in this catalog. We would be glad to share our specialty design programs with you to provide disconnects matching the precise specifications required. NOTE: and weights may vary.please consult factory for certified drawings. 2 Electric Manufacturing Company

Lighting Disconnect Series TDLK Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse 250 TDLK-130.52 1.5 2.08 2.25 2.08 27 500 TDLK-170 1.04 3.0 4.17 4.5 4.17 35 750 TDLK-190 1.56 4.5 6.25 6.25 6.25 45 1000 TDLK-200 2.08 3.25 8.33 2.0 2.00 6.33 7.0 49 1500 TDLK-210 3.13 5.0 12.50 5.0 5.00 7.50 8.0 55 2000 TDLK-230 4.17 6.25 16.67 10.0 9.00 7.50 8.0 69 3000 TDLK-250 6.25 10.0 25.00 10.0 10.00 15.00 15.0 82 Approx. NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Duplex on 1000 through 3000, optional on 250-750. Dedicated physical earth terminal. Options: Green, ON pilot light available as additional cost option. Other voltage combinations available. EN 60204-1 Series TDLK A B C D E F 250-2000 9.00 14.75 9.13 5.75 13.75.340 3000 10.75 14.75 9.13 5.75 13.75.340 Series TDLK Outline Drawings S2 S1 1K & GREATER Receptacle Supplied on 1 k and Larger *F3 fuse size will vary if Side View 1.800.428.2626 www.dongan.com 3

Lighting Disconnect Series TDLK 12 Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse Approx. 250 TDLK-130.52 1.5 2.08 2.25 2.08 29 500 TDLK-170 1.04 3.0 4.17 4.5 4.17 37 750 TDLK-190 1.56 4.5 6.25 6.25 6.25 47 1000 TDLK-200 2.08 3.25 8.33 2.0 2.00 51 1500 TDLK-210 3.13 5.0 12.50 5.0 5.00 57 2000 TDLK-230 4.17 6.25 16.67 10.0 9.00 71 3000 TDLK-250 6.25 10.0 25.00 10.0 10.00 96 NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). All overcurrent protection provided Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Gasketed receptacle available as an added cost option on all sizes. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations available. EN 60204-1 Series TDLK 12 A B C D E F G 250-2000 12.75 14.00 9.38 9.38 13.00.340 4.63 3000 15.119 18.00 11.38 11.50 17.00.340 7.50 Series TDLK 12 Outline Drawings S2 S1 1K & GREATER Optional Receptacle Available *F3 fuse size will vary if Bottom View 4 Electric Manufacturing Company

Lighting Disconnect Series TDEK 380 V* NEMA 3R/IP23 Enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Fuse F3* Lighting Complies with automotive industry specifications. Gasketed receptacle available as an added cost option on all sizes. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations available. Duplex F1 H1 Fuse EN 60204-1 Approx. 250 TDEK-130.66 2.08 2.25 2.08 31 500 TDEK-170 1.32 4.17 4.5 4.17 35 750 TDEK-190 1.97 6.25 6.25 6.25 45 1000 TDEK-200 2.63 8.33 9.0 8.33 49 1500 TDEK-210 3.95 12.50 15.0 12.50 55 2000 TDEK-230 5.26 16.67 20.0 16.67 69 3000 TDEK-250 7.90 25.00 25.0 25.00 86 * Primary max amps for other voltages may be obtained by dividing by line voltage Series TDEK (380,400) (416,440) (575) A B C D E F 250-2000 9.00 14.75 9.13 5.75 13.75.340 3000 10.75 14.75 9.13 5.75 13.75.340 Series TDEK Outline Drawings 120 110 S2 S1 OPTIONAL DUPLEX RECEPTACLE AILABLE Optional Receptacle Available *F3 fuse size will vary if Side View 1.800.428.2626 www.dongan.com 5

Lighting Disconnect Series TDEK 12 380 V* Fuse F3* Lighting Receptacle Fuse Approx. 250 TDEK12-130 0.66 2.08 2.25 2.08 33 500 TDEK12-170 1.32 4.17 4.5 4.17 37 750 TDEK12-190 1.97 6.25 6.25 6.25 47 1000 TDEK12-200 2.63 8.33 9.0 8.33 51 1500 TDEK12-210 3.95 12.50 15.0 12.50 57 2000 TDEK12-230 5.26 16.67 20.0 16.67 71 3000 TDEK12-250 7.90 25.00 25.0 25.00 100 * Primary max amps for other voltages may be obtained by dividing by line voltage NEMA 12/IP65 Enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED Complies with automotive Both sides of secondary isolated from ground. is copper wound with electrostatic shield (earth metal screen). Primary overcurrent protection provided: Secondary fuse holders only for Series TDEK 12 Outline Drawings 13/32 x 1 Z\x fuses. Complies with automotive industry specifications. Duplex on all sizes. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations available. A B C D E F G 250-2000 12.75 14.00 9.38 9.38 13.00.340 4.63 3000 15.19 18.00 11.38 11.50 17.00.410 7.50 F1 H1 EN 60204-1 Series TDEK 12 (380,400) (416,440) (575) 120 110 S2 S1 OPTIONAL DUPLEX RECEPTACLE AILABLE Optional Receptacle Available *F3 fuse size will vary if Side View 6 Electric Manufacturing Company

Disconnect - Auxiliary Power Series TDAK Fuse F1 & F2 * Lighting Duplex Approx. 500 TDAK-170 1.04 3.0 4.17 35 750 TDAK-190 1.56 4.5 6.25 45 1000 TDAK-200 2.08 3.25 8.33 49 1500 TDAK-210 3.13 5.0 12.50 55 2000 TDAK-230 4.17 6.25 16.67 2.00 15.00 69 3000 TDAK-250 6.25 10.0 25.00 10.00 15.00 82 * Lighting amps and. duplex amps must not exceed total secondary max amps when used simultaneously. NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED. Both sides of secondary isolated from ground. is copper wound with electrostatic shield (earth metal screen). Primary overcurrent protection provided: Secondary fuse holders only for 13/32 x 1 Z\x fuses. Complies with automotive industry specifications. Duplex on all sizes. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations available. EN 60204-1 Series TDAK A B C D E F 500-2000 9.00 14.75 9.13 5.75 13.75.340 3000 10.75 14.75 9.13 5.75 13.75.340 Series TDAK Outline Drawings Side View 1.800.428.2626 www.dongan.com 7

Disconnect - Auxiliary Power Series TDAK 12 Fuse F1 & F2 Fuse F3* & Lighting Receptacle Approx. 500 TDAK12-170 1.04 3.0 4.17 4.5 4.16 37 750 TDAK12-190 1.56 4.5 6.25 6.25 6.25 47 1000 TDAK12-200 2.08 3.25 8.33 9.0 8.33 51 1500 TDAK12-210 3.13 5.0 12.50 15.0 12.50 57 2000 TDAK12-230 4.17 6.25 16.67 20.0 16.66 71 3000 TDAK12-250 6.25 10.0 25.00 25.0 25.00 96 NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. 200K AIC RATED. Both sides of secondary isolated from ground. is copper wound with electrostatic shield (earth metal screen). All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Gasketed receptacle available as an added cost option on all sizes. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations available. EN 60204-1 Series TDAK 12 A B C D E F G 500-2000 12.75 14.00 9.38 9.38 13.00.340 4.63 3000 15.19 18.00 11.38 11.50 17.00.410 7.50 Series TDAK 12 Outline Drawings Optional OPTIONAL Receptacle DUPLEX Available Side View *F3 fuse size will vary if 8 Electric Manufacturing Company

Series TLAK Dual Secondary - Lighting Disconnect Fuse F1 & F2 One Secondary 1 Secondary 2 Approx. One One Fuse F3* & Two Two Two Fuse F5 1000 TLAK-170170 2.08 5.0 500 4.17 4.5 500 4.17 4.5 49 1500 TLAK-200170 3.13 5.0 1000 8.33 9.0 500 4.17 4.5 55 1500 TLAK-190190 3.13 5.0 750 6.25 6.25 750 6.25 6.25 55 1500 TLAK-170200 3.13 5.0 500 4.17 4.5 1000 8.33 9.0 55 1750 TLAK-190200 3.64 6.0 750 6.25 6.25 1000 8.33 9.0 69 3000 TLAK-200230 6.25 10.0 1000 8.33 9.0 2000 16.67 20.0 82 3750 TLAK-190250 7.81 12.0 750 6.25 6.25 3000 25.00 25.0 84 4000 TLAK-200250 8.33 12.0 1000 8.33 9.0 3000 25.00 25.0 86 NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. 50 / 60 Hz. Secondary One: 120 C. Secondary Two: 120 C. 200K AIC RATED. Disconnect features dual isolated secondaries for load isolation. Secondary One: Both sides ungrounded. Secondary Two: One side grounded. is copper wound with electrostatic shield (earth metal screen) between primary and secondary and between secondary one and secondary two. All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Duplex receptacle optional on all sizes. Green ON pilot light optional on all sizes. A B C D E F 1000-1750 9.00 14.75 9.13 5.75 13.75.340 3000-4000 10.75 14.75 9.13 5.75 13.75.340 Dedicated physical earth terminal. Other options: Other voltage combinations available. EN 60204-1 Series TLAK L1 L2 Series TLAK Outline Drawings PE S4 S3 OPTIONAL DUPLEX Optional Receptacle Available Side View *F3 fuse size will vary if 1.800.428.2626 www.dongan.com 9

Dual Secondary - Lighting Disconnect Series TLAK 12 Fuse F1 & F2 One Secondary 1 Secondary 2 Approx. One One Fuse F3* & Two Two Two Fuse F5 1000 TLAK12-170170 2.08 5.0 500 4.17 4.5 500 4.17 4.5 51 1500 TLAK12-200170 3.13 5.0 1000 8.33 9.0 500 4.17 4.5 57 1500 TLAK12-190190 3.13 5.0 750 6.25 6.25 750 6.25 6.25 57 1500 TLAK12-170200 3.13 5.0 500 4.17 4.5 1000 8.33 9.0 57 1750 TLAK12-190200 3.64 6.0 750 6.25 6.25 1000 8.33 9.0 71 3000 TLAK12-200230 6.25 10.0 1000 8.33 9.0 2000 16.67 20.0 96 3750 TLAK12-190250 7.81 12.0 750 6.25 6.25 3000 25.00 25.0 98 4000 TLAK12-200250 8.33 12.0 1000 8.33 9.0 3000 25.00 25.0 100 NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. 50 / 60 Hz. Secondary One: 120 C. Secondary Two: 120 C. 200K AIC RATED. Disconnect features dual isolated secondaries for load isolation. Secondary One: Both sides ungrounded. Secondary Two: One side grounded. is copper wound with electrostatic shield (earth metal screen) between primary and secondary and between secondary one and secondary two. All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Green ON pilot light provided. Gasketed receptacle optional on all sizes. A B C D E F G 1000-1750 12.75 14.00 9.38 9.38 13.00.340 4.63 3000-4000 15.19 18.00 11.38 11.50 17.00.410 7.50 Dedicated physical earth terminal. Other options: Other voltage combinations available. EN 60204-1 Series TLAK 12 L1 L2 Series TLAK 12 Outline Drawings PE X1 F3 F S4 S3 OPTIONAL DUPLEX RECEPTACLE AILABLE Optional Receptacle Available Bottom View *F3 fuse size will vary if 10 Electric Manufacturing Company

Lighting Disconnect Series ADLK Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse 250 ADLK-130.52 1.5 2.08 2.25 2.08 27 500 ADLK-170 1.04 3.0 4.17 4.5 4.17 31 750 ADLK-190 1.56 4.5 6.25 6.25 6.25 35 1000 ADLK-200 2.08 3.2 8.33 2.0 2.08 6.33 7.0 44 1500 ADLK-210 3.13 5.0 12.50 5.0 5.00 7.50 8.0 49 2000 ADLK-230 4.17 6.25 16.67 10.0 9.00 7.50 8.0 56 3000 ADLK-250 6.25 10.0 25.00 10.0 10.00 15.00 15.0 69 Approx. NEMA 1 / IP 23 enclosure Primary Voltage: 480 C Secondary Voltage: 120 C. 60 Hz 200K AIC RATED. One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). All overcurrent protection provided: Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Duplex on 1000 through 3000, optional on 250-750. Dedicated physical earth terminal. Options: Green or red ON pilot light available as additional cost option. Other voltage combinations available. Series ADLK X2 A B C D E F 250-3000 9.00 14.75 9.13 5.75 13.75.340 Series ADLK Outline Drawings S1 1K & GREATER Optional Receptacle Available *F3 fuse size will vary if Bottom View 1.800.428.2626 www.dongan.com 11

Lighting Disconnect Series ADLK 12 Fuse F1 & F2 Fuse F3* Lighting Receptacle Fuse 250 ADLK12-130.52 1.5 2.08 2.25 2.08 29 500 ADLK12-170 1.04 3.0 4.17 4.5 4.17 33 750 ADLK12-190 1.56 4.5 6.25 6.25 6.25 37 1000 ADLK12-200 2.08 3.2 8.33 9.0 8.33 46 1500 ADLK12-210 3.13 5.0 12.50 15.0 12.50 51 2000 ADLK12-230 4.16 6.25 16.67 20.0 16.67 58 3000 ADLK12-250 6.25 10.0 25.00 25.0 25.00 71 Approx. NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. 200K AIC RATED. One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). Complies with automotive industry specifications. All overcurrent protection provided Secondary - Supplementary fuses (13/32 x 1 Z\x ). Gasketed receptacle available as additional cost option. Green ON pilot light provided. Dedicated physical earth terminal. Options: Other voltage combinations are available. Red ON pilot light available. Series ADLK 12 X2 A B C D E F G 250-3000 12.75 14.00 9.38 9.38 13.00.340 4.63 Series ADLK 12 Outline Drawings S1 1K & GREATER Optional Receptacle Available *F3 fuse size will vary if Bottom View 12 Electric Manufacturing Company

Large Lighting Disconnect Series TDGK 12 Fuse F1 & F2 Fuse F3* Fuse with Receptacle F3* Fuse with Receptacle Approx. 5000 TDGK12-300 10.41 15.0 41.66 45.0 35.0 6.0 125 7500 TDGK12-330 15.62 25.0 60.00 60.0 50.0 10.0 150 NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. 200K AIC RATED. Large capacity - 5000 and 7500. One side of secondary grounded. is copper wound with electrostatic shield (earth metal screen). Green ON pilot light provided. All overcurrent protection provided: Secondary - Supplementary fuses (1 1/16 x 2 i# ). Gasketed duplex receptacle available as additional cost option. Dedicated physical earth terminal. Options: Other voltage combinations available. Series TDGK 12 A B C D E F G 5000-7500 15.19 18.00 11.50 11.50 17.00.410 7.50 Series TDGK 12 Outline Drawings OPTIONAL DUPLEX Optional Receptacle Available *F3 fuse size will vary if Bottom View 1.800.428.2626 www.dongan.com 13

Compact - Lighting Disconnects Series TMAK, TMBK and TMCK The Compact Series Lighting Disconnects are designed to minimize backplate footprints to save valuable control panel space. The Compact Series are available in three standard circuits with four sizes for each circuit configuration. Epoxy encapsulated, the Compact Series offers cool operating temperatures, a green ON pilot light, and circuit options that include a duplex receptacle as well as grounded and ungrounded secondaries. Circuit Style Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse Approx. 250 TMAK-130 A.52 1.5 2.08 15 500 TMAK-170 A 1.04 3.0 4.17 20 750 TMAK-190 A 1.56 4.5 6.25 25 1000 TMAK-200 A 2.08 6.0 8.33 30 250 TMBK-130 B.52 1.5 2.08 2.25 2.08 15 500 TMBK-170 B 1.04 3.0 4.17 4.5 4.17 20 750 TMBK-190 B 1.56 4.5 6.25 6.25 6.25 25 1000 TMBK-200 B 2.08 6.0 8.33 9.0 8.33 30 250 TMCK-130 C.52 1.5 2.08 2.25 2.08 2.25 15 500 TMCK-170 C 1.04 3.0 4.17 4.5 4.17 4.5 20 750 TMCK-190 C 1.56 4.5 6.25 6.25 6.25 6.25 25 1000 TMCK-200 C 2.08 6.0 8.33 9.0 8.33 9.0 30 Total of lighting amps and duplex amps must not exceed secondary amp rating. Fuse sizes of F3 and are based on the load and maximum secondary amps. * F3 fuse size will vary if NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. 200K AIC RATED. Compact, panel space-saving design. Choice of three circuit designs. is copper wound with electrostatic shield (earth metal screen). Green ON pilot light provided. Primary overcurrent protection provided: Dedicated physical earth terminal. Options: Other voltage combinations available. Complies with automotive industry specifications. TOAK, TOBK & TOCK open style available. Please contact your Representative or our offices for literature on the full line of Disconnects, s and other products. 14 Electric Manufacturing Company

Compact - Lighting Disconnects Circuit Configurations Series TMAK Series TMBK Series TMCK G G G A B C D E F 250-1000 7.50 8.75 10.38 6.88 6.0.250 Series TMAK Series TMBK & TMCK 1.800.428.2626 www.dongan.com 15

OEM Product Groups Series TDFM12 TDFM12 series is a flange mount lighting disconnect in a NEMA 12 enclosure. The enclosure has provisions for side mounting or base mounting. This is used predominantly in automotive plants. Standard voltage is 480 to 120. s from 1000-3000 Power-on pilot light All overcurrent protection provided Lockable Allen Bradley 30 amp switch Continuous welded seams Hinged door with gasketing Special voltages available Other options- consult factory RATING CATALOG NUMBER WEIGHT (LBS) 1000 TDFM12-200 50 1500 TDFM12-210 63 2000 TDFM12-230 70 3000 TDFM12-250 75 General Purpose Dry Type Distribution Single Phase, Three Phase, Buck Boost, Motor Drive Isolation, Custom Designs Single Phase, 50-100 k - Series 35, 80, 85, 61, 41 Three Phase, 3 k - 150 k - Series 63, 73, 76, 83 Buck - Boost, 50-5 k - Series 35, 80, 85 Motor Drive Isolation, 3 k - 145 k - Series 63 CE Marked Single and Three Phase Units - Series ES-11, Series ES-31 K Factor, 15 k - 150 k - Series TK Custom Designs - Core and Coil Designs - Autotransformers - UL and CSA Family Approvals Industrial Control s, Servo Drive Isolation s Century Series 50-1000 102, 103, 107, 109 Primary Installed Fuse Available Series 50, Screw Terminals - Domestic Suffix 052, 053, 054, 056, 134 - Export Suffix 058, 059 Series HC, Molded Terminals - Suffix -41, -44, -46, -47 CE Marked Units - Series ES-10 - Suffix.326,.366,.376,.386 16 Electric Manufacturing Company

C.. s and Custom Magnetics Factory and Local Warehouse Stocks for: Industrial Control s General Purpose s Single Phase Three Phase Motor Drive Isolation s Control s K - Factor s High Voltage Ignition Gas Ignition Oil Ignition Solid State Lighting Disconnects Signaling Hospital Isolation Epoxy Encapsulated CE Marked s Auto s High Voltage s Solar and Wind Energy s DOE Energy Efficient s Custom Designs Available: Domestic & Export Voltages Custom Colors Special Frequencies Custom Enclosures Match Current or Custom Core & Coil Units CE Marked s Chokes Reactors Comprehensive Family Approvals for Electric Manufacturing Company 2987 Franklin Street Detroit, MI 48207 USA la s s I Bauart gepruft.. TUV Rheinland latin g E N 6 0 7 4 2 Is o 800.428.2626 +1.313.567.8500 Fax: 586.296.2553 www.dongan.com sales@dongan.com Pioneer Company A Wholly Owned Subsidiary 500 Cedar Street Pioneer, OH 43554 USA LD-11-16 Engineered Solutions Since 1909