Installation and Service Manual JB-1 System Sewage Ejector Pump Package

Similar documents
Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

SHEF30 Submersible Sump/ Effluent Pump

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps

Installation and Service Manual SK50 Submersible Sewage Ejector Pump

SP40 Submersible Sewage Ejector Pump

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

INSTALLATION AND SERVICE MANUAL MSKV50 Submersible Sewage Ejector Pump

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

ESE Series Cast Iron Sewage Pumps

PRE-PLUMBED SEWAGE SYSTEM

OWNER S MANUAL Submersible Sewage Ejector Pumps

MODEL SPC-PANEL. Pump Controls for 2 HP Grinder Pumps

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SIMPLEX, SINGLE PHASE PUMP CONTROL PANEL Model SPC-PANEL Pump Controls for 2 HP Grinder Pumps

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

INSTALLATION AND SERVICE MANUAL MESPD50/MESPD100 Submersible Effluent Pump

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

SUBMERSIBLE SUMP PUMPS

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

SUBMERSIBLE SUMP PUMPS

Pump Installation and Service Manual HRS Hydromatic Retractable System

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

SUBMERSIBLE SEWAGE PUMPS

SAE Engine Mount. Selection For Pumping Application. Matching Pump End To Engine. Type B Centrifugal Pumps Close coupled pump ends.

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

SPC-PANEL Simplex, Single Phase Pump Control Panel

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps

Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump

Ion Technologies WC33 Submersible Sump Pump

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP

HYDROMATIC SPD50H/100H SUBMERSIBLE HIGH HEAD, DOUBLE SEAL EFFLUENT

PUMP VAULT S.T.E.P. SYSTEM

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

(Class I, Division 1, Groups C & D): FM

MODEL S4F SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

HYDROMATIC SK75/100 SUBMERSIBLE SEWAGE EJECTOR

MODELS S4LX, S4BX, S4KX, S4QX, H4QX, S4LVX, S6AX, S6LX and S8FX

METAL-TO-METAL RAIL SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

StormPro BA Series Sump Pump

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

(Class I, Division 1, Groups C & D): FM

Model B1-1/2XQBS-11. Model B1-1/2XQBS-18. Model B1-1/2XQBS-26

MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP

Matala. VersiFlow Series. Instruction and Maintenance Manual

OWNER S MANUAL CP, CB SERIES CENTRIFUGAL PUMP

AUTOMATIC SUBMERSIBLE UTILITY PUMP

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

METAL-TO-METAL RAIL SYSTEM INSTALLATION AND SERVICE MANUAL

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Submersible Sewage Ejector Pump

HYDROMATIC HE8/HE12/HE20/HE25/ HE30/HE35/HE50 HIGH HEAD FILTERED EFFLUENT

MODELS HPGF/HPGFH, HPGH/HPGHH

StormPro BCV400 Sewage Ejector Pump

SUBMERSIBLE GRINDER PUMP Models HPGF/HPGFH; HPGH/HPGHH

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.

HYDR-O-RAIL SYSTEM. Pump Installation and Service Manual

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

MODELS HPGFX/HPGHX & HPGFHX/HPGHHX

THERE IS NO OTHER EXPRESS WARRANTY.

HYDROMATIC SPX50/SPX50H EXPLOSION PROOF, SEWAGE EJECTOR

GeyserMax-Flow Series

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

SUBMERSIBLE SWIMMING POOL DRAINER

GARDEN HOSE UTILITY PUMP

SUBMERSIBLE SOLIDS HANDLING PUMP Models S4T, S8L, S8LA, and S12L

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

SUBMERSIBLE SEWAGE PUMP RECESSED IMPELLER

Owner s Manual Drill and Light Weight Portable Utility Pumps

MODELS WGL20, WGL20H and WGL20F

NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: FM2369

HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

MODELS H3H, H4H, S4M, S4P, S4HRC and S4MRC SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Transcription:

Installation and Service Manual JB-1 System Sewage Ejector Pump Package NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system. 293 WRIGHT STREET, Delavan, WI 53115 WWW.hydromatic.COM PH: 888-957-8677 269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5 PH: 519-896-2163 2013 Pentair, Ltd. All Rights Reserved. W-03-373 (Rev. 03/04/13)

General Information Thank you for purchasing your Hydromatic pump. To help ensure years of trouble-free op er a tion, please read the following manual carefully. Before Operation: Read the following in structions care ful ly. Reasonable care and safe meth ods should be practiced. Check local codes and requirements before installation. Attention: This manual contains important information for the safe use of this product. Read this manual completely before using this product and refer to it often for con tin ued safe product use. DO NOT THROW AWAY OR LOSE THIS MAN U AL. Keep it in a safe place so that you may refer to it often. Warning: Before handling these pumps and controls, always disconnect the power first. Do not smoke or use sparkable electrical devices or flames in a septic (gaseous) or possible septic sump. California Proposition 65 Warning This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Pump Warning Warning: Risk of Electrical Shock for your protection always disconnect pump from the power source before handling. If the pump is wired direct, dis con nect power to the control box. Grounded pumps are supplied with a 3-prong 2 grounded plug to help protect you against the pos si bil i ty of electrical shock. Do not remove the ground pin from the plug. To reduce the risk of electrical shock, a prop er ly grounded receptacle or control box of grounding type must be installed and protected by a ground fault circuit in ter rupt er (GFCI) in accordance with na tion al electrical code and applicable local codes. Warning: Do not smoke or use sparkable elec tri cal devices or flame in a septic (gas eous) or possible septic atmosphere. 1. Inspect all materials before ac cept ing them. If the damage is apparent on the outside of the box, claims for damages should be filed with the shipper. Hidden damage can occur during shipment. If the unit is found to be damaged after opening the box, contact your local Hydromatic distributor before using. 2. Before installation or operation care ful ly read all the information pro vid ed with this product. Familiarize yourself with specific details re garding in stal la tion and use before attempting the installation. 3. Make certain that the ground fault interrupter pro tect ed receptacle or control box is within reach of the pump s power cord. Use of ex ten sion cords that are too long or too light do not deliver sufficient volt age to the pump motor. They could also present a safety hazard if the insulation were to become damaged or the con nec tion end were to fall into a damp or wet area. 4. Check to be sure your power source is adequate to handle the amperage re quire ments of the motor as in di cat ed on the pump, and that the volt age matches that indicated on the pump. Make sure the pump s elec tri cal supply circuit is equipped with a separate 15 amp circuit breaker according to the National Electrical Code. 5. Testing for Ground. As a safe ty measure, each electrical out let should be checked for ground. If the system is not properly grounded or you are not sure, call a li censed electrician for assistance. Caution: All plumbing must be in stalled to meet local codes. The unit must be vented. Caution: Installation and check ing of all electrical circuits and hardware should be per formed only by a qual i fied licensed electrician. Caution: Repair and service should be per formed by an authorized Hydromatic service station only. Caution: Refer to the appropriate man u al for operation and maintenance of the pump that is provided with this system. Note: Use extreme caution around elec tri cal devices. Electrical shock may occur. Note: See the performance curve for this unit on page 7 of this manual. This pumping unit is designed to discharge sewage up to a max i mum of 18 feet total dynamic head (T.D.H.) including friction loss of pipe and fittings. This unit should not be used with systems requiring total dynamic heads above 18 feet. Note: Do not use wax seal having flange that extends into tank; it may cause clogging. If a floor is installed over the tank, use toilet manufacturer designed floor flange extender seal kit.

Failure to heed above cau tions could result in injury or death. Pump System Installation The JB-1 is designed as a relatively easy project provided the installation instructions are followed and na tion al or lo cal elec tri cal and plumbing codes are followed. Bathrooms are usually small. Because so many activities occur in such a small place, thorough planning is a must. Get the right tools for the job before beginning, and make a specific and thorough plan. You may need to make drawings, obtain a build ing per mit and/or have your work in spect ed. Be prepared; read all in struc tions that come with this product before installation. Basic Tools for the Job: (Some of these tools may not be needed de pend ing on the type of installation chosen) Adjustable wrench Wallboard knife Clamps Ratchet wrench Flat pry bar Sponge Hammer Wrecking bar Multi-meter Masonry hammer Hacksaw Paint brush Wood chisel Screwdrivers Carpenter s level Masonry chisel Tape measure Expandable plumber s plug Putty knife Marker Cloths, rags Notched trowel Staple gun Neon circuit tester 1. The JB-1 can be installed as a free standing unit or can be enclosed. 2. Maintain at least 6" between major bathroom fixtures. 3. If installing a shower or bathtub, do not install them within 60" of any light switch. Note: The above recommendations meet or exceed national and most local building codes, and are meant only as recommendations when installing the JB-1 alone or as part of a com plete bath room. 1. Position tank at desired location that is level within 1/8" for the length. Ensure that nails, screws, or other sharp objects do not punc ture the tank. 2. For an enclosed installation the unit is designed to fit within a 2" x 6" floor joist. Note: A floor flange extender seal kit must be used for this type of installation, and is not included with the JB-1 system. 3. Determine the location for the JB system with attention given to ac cess to the discharge and vent lines. Make the necessary measurements, and determine the necessary fit tings and piping that are required. Be sure to observe all local plumbing codes. 4. Install the long bolts and nuts (Fig. 3, Item 3) that are used to fasten the toilet to the tank or subfloor. Note: A stan dard floor flange is not re quired. The position of the toilet must be determined to allow the longer bolts to be inserted in the correct holes. Install the wax ring making sure to align closet bolts for installation of the toilet bowl in the desired di rec tion. (i.e., If the vent and dis charge pipe is to be in stalled be hind the wall, the toilet bowl/flush tank will be parallel to the pump housing and piping.) 5. Set pump in pump housing with discharge toward the right back cor ner as viewed from toilet open ing. The vertical float switch must line up square in the middle of the cor ner baffle located inside the pump chamber. Shim pump as required. 6. Apply foam gasket (Fig. 3, Item 6) to flange of pump chamber. For best results, overlap ends or gasket approximately 1/2". 7. Place 2" straight flange in 2-3/8" hole; this is the discharge. 8. Install the discharge pipe (approximately 18" in length) in lid as fol lows. Lu bri cate the 2" rubber seal with soapy water and push the 2" pipe through the seal. 9. Install the lid on the tank as fol lows. Push the 2" discharge pipe down until approximately 1-1/2" is protruding through the lid. Pull pump power cord up out of the tank and hang over edge of the pump housing. Screw threaded adapter into the pump discharge by rotating the lid assembly until hand tight. Feed end of pump pow er cord and the cord seal through small hole in cover in the lid. (Fig. 3, Item 8) Push lid down into po si tion on the pump well. Tight en pump 2" discharge pipe with a strap wrench. Do not press cord seal into lid at this time. (Ref. Step 21) Bolt lid in place with (20) 1/4"-20 bolts and washers pro vid ed. (Fig. 3, Items 1, 2) 10. Install the threaded vent pipe or glue the vent pipe to a male adapter. 3

11. The discharge pipe should protrude approximately 4" above the sur face of the lid. Attach the check valve (Fig. 3, Item 4) to the dis charge pipe with the arrow on the check valve body, indicating flow, pointing away from the pump. 12. Connect 2" discharge pipe and 2" vent pipe into house plumbing. Caution: The unit must be vent ed ac cord ing to local codes. Toilet will not flush unless properly vented. 13. If additional fixture(s) are being added to your installation, a 2" rub ber pipe seal must be inserted in the tank. Refer to Fig. 1 for location. Note: The bottom of the additional fixture, a 3" diameter hole, must be 5" minimum above the base of the tank, as shown in Fig. 1. 14. Drill 3" diameter hole at the de sired location on one of the four sides of the pump chamber sur face. The center line of the hole must be a minimum of 1" above the tank top surface if one of the sides is chosen for the flange mounting. 15. After choosing the spot for the hole, lightly center punch hole cen ters on pump chamber. 16. Drill a 3" diameter hole with a hole saw for mounting the 2" rubber pipe seal to the tank. Warning: Hole diameter must not be oversized or the tank may leak. The hole should be no bigger than 3.05". 17. Lubricate 2" rubber pipe seal with soapy water and push it into 3" drilled hole. Lubricate fixture drain pipe and push through the 2" rubber pipe seal into the pump chamber. Pipe must not interfere with the op er a tion of or touch the pump. 18. Test the pump by partially filling the tank to a depth of approximately 4". This can be checked with the tape measure through the opening where toilet is to be installed. Plug in the pump. The pump will turn on before the water level reaches 4-1/2". Caution: Unplug the pump before adjusting the switch. If the pump does not turn on before 4-1/2", slide the up per rubber stop down the float rod and retest. If the pump starts before 3-1/4", slide the upper stop to a higher point on the float rod and retest. The pump must turn on between 3-1/4" and 4-1/2". 19. Check the tank for leaks. Attach the cord to the discharge or vent pipe. Do not leave an excess length of cord inside tank. It may interfere with the proper operation of the pump. 20. Test the tank discharge pipe and vent pipe with 10 feet water column if required by local code. Plug the 4" diameter opening in the tank with an expandable plumbers plug. Make certain the tank lid screws are torqued down properly. The system can now be tested per code requirements. Warning: The tank and lid will ex pand with the water column pressure while tested. If the tank is to be in stalled under the floor, the testing should be completed before the floor is in stalled. 21. Install wax toilet bowl seals at hole and install toilet in place following the instructions from the wax seal package. NOTE: Do not use wax seal having flange that extends into tank; it may cause clogging. If a 1/2" or 1/4" floor is installed over the tank, the ap pro pri ate floor flange extender seal kit must be used. See item 3 in the installation instructions. 22. Hook up water line to toilet. Turn on water and fill tank. Test for leaks, flush toilet and allow pump to cycle to ensure proper operation. 4

Pump Warning END VIEW SIDE VIEW Figure 1 Figure 2 5

Troubleshooting information for pump only. For other ques tions or prob lems, please contact your au tho rized Hydromatic service center. Servicing should be per formed only by an au tho rized Hydromatic service center. Warning: Always disconnect the pump from power source before handling or making any adjustments. Always wear rubber boots when there is water on the floor and you must unplug the pump or make any adjustments. Note: Automatic thermal overload protects the sealed-in-oil motor. Running dry may overheat the motor and activate the overload protec tor until the motor cools. Pump does not run or just hums. 1. Line circuit breaker may be off, blown or loose. 2. Water level in sump may be too low to activate automatic float. 3. Power cord plug may not be making contact in receptacle. 4. If all symptoms check OK, motor winding may be open; take to authorized service center or distributor for check. Pump runs but does not deliver water, or small amount of water. 1. Check valve may be installed backward. Arrow on valve points in direction of flow. 6 Pump Troubleshooting 2. Discharge gate valve, if used, may be closed. 3. Pump may be air locked. Start and stop several times by plugging and unplugging cord. Check vent hole in pump case for plugging. Hydromatic pumps have a small air vent hole in the impeller cavity to let out trapped air. If this hole becomes plugged, pump may air lock. To break the air lock, use a small screwdriver to clear hole in the impeller cavity. As a secondary precaution in installations of this type 1 16" hole should be drilled in the discharge pipe below the check valve. The check valve should be 12 to 18 inches above pump discharge. Do not put check valve directly into pump discharge opening. Note: In sumps where the pump is operating daily, air locking rarely occurs. 4. Pump head may be too high. Pump cannot deliver water over 21.0' vertical lift. Horizontal distance does not affect pumping, except for friction loss through the pipe. 5. Inlet in pump base may be clogged. Remove pump and clean out openings. 6. Impeller or volute openings may be plugged or partially plugged. Re move pump and clean out. 7. Pump impeller may be partially clogged causing motor to run slow, resulting in motor overload. Clear impeller. Fuse blows or circuit break er trips when pump starts. 1. Inlet in pump base may be clogged. Remove pump and clean out open ings. 2. Impeller or volute openings may be plugged or partially plugged. Re move pump and clean out. 3. Pump impeller may be partially clogged causing motor to run slow, resulting in motor overload. Clear impeller. 4. Fuse size or circuit breaker is too small. 5. Defective motor stator: return to authorized Hydromatic service center or distributor for verification. Motor runs for short time then stops. Then after short period starts again. Indicates tripping over load caused by symptom shown. 1. Inlet in pump base may be clogged. Remove pump and clean out open ings. 2. Impeller or volute openings may be plugged or partially plugged. Re move pump and clean out. 3. Pump impeller may be partially clogged causing motor to run slow, resulting in motor overload. Clear impeller. 4. Defective motor stator; return to authorized Hydromatic service center or distributor.

JB-1 System Parts List Figure 3 Installation Hardware Kit 4 item Description Qty. 1 1/4" 20 x 5/8" Hex Head Bolts 20 2 Flat Washers.320 I.D. 20 3 5/16" x 2" Stud and Nuts 2 4 Check Valve 1 5 Wax Ring (Retail Boxed) 1 6 1/2" Foam Gasket Material 1 7 2" Adapt-A-Flex Pipe Grommet 2 8 Adapt-A-Flex Pipe Grommet for Cords 1 9 2" x 32" Long Schedule 40 PVC, with 2" NPT Male Adapter 1 2 1 9 7 8 8 25 SKV40 CURVE 7 20 HEAD-METERS 5 4 HEAD-FEET 15 4/10 HP 6 3 10 2 0 0 20 40 60 80 Capacity-U.S. G.P.M. 5 Liters/Second 0 1 2 3 4 5 SKV40 CURVE 3 7

Limited Warranty HYDROMATIC warrants to the original consumer purchaser ( Purchaser or You ) of HYDROMATIC Sump Pumps, Effluent Pumps, Sewage Pumps (other than 2-1/2 ), and Package Systems, that they will be free from defects in material and workmanship for the Warranty Period of 36 months from date of manufacture. Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void. Your only remedy, and HYDROMATIC s only duty, is that HYDROMATIC repair or replace defective products (at HYDROMATIC s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable. EXCEPTIONS: Hydromatic Special Application Pumps, Battery Back-Up Sump Pumps, Filtered Effluent Pumps, Grinder Pumps, and 2-1/2 Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture, whichever comes first. HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state. This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011. HYDROMATIC 293 Wright Street, Delavan, WI 53115 Phone: 888-957-8677 Fax: 800-426-9446 Web Site: hydromatic.com