Lighting Control Unit Installation Instructions

Similar documents
Outdoor Sensor Assembly (Veris) Installation Instructions

CMS Torpedo Sensor Installation Instructions

Model LA 4300 Time Delay OFF Controller

Model LA 4400 Time Delay OFF Controller

Model LA 4100 Time Delay OFF Controller

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

CONSOLE MANAGEMENT CONTROLLER

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Patient Care Facility

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

ComfortPoint Programmable Lon, VAV/Unitary Controllers

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Installation Instructions: Read these instructions in its entirety before performing any installation work.

MA-5200 Series MA-5300 Series

Electro-Mechanical Swing Operator. Table of Contents

Universal Deck & Rail Cart

Installation Instructions Studio Makeup Station

MF4E MF4E

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

University of Houston Master Construction Specifications Insert Project Name

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

AC 2307 Seven-Slot T1 Mini Repeater Apparatus Case

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

INTRODUCTION / TABLE OF CONTENTS

Nota Conductor s Chair

MIL-24/2600Q MIL-24/3200DQ

CP (Vdc) CP (Milliamp) CP (Slidewire)

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

AccuPower AQU126B Installation Instructions

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

AccuPower AQU128B Installation Instructions

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

DART Charger Product Description, Information and Specification

MC-351, 421, 431, MC-4311

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

TC26-B Vehicle Sensor

OWNERS MANUAL JANUARY 2007 ISO

CV41. Vehicle Mounting Kit. Reference Guide

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Electric Actuator Instructions

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Powerware Vdc Extended Battery Cabinet User s Guide.

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

UHC-202 Hardware Guide

Powers TM Controls EA 338 Electronic Actuator

Music Stands CONTENTS. Assembly and Owner s Manual. Note: Note:

8300 Series Installation Guidelines

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

Bussmann series Quik-Spec Power Module Switch elevator disconnect

OnBoard Drum Major Podium

Quick Connection Cabinet (QCC)

Wenger Corporation 2011 Printed in USA 08/11 Part #158E006-02

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

BroadBand PowerShield. 20 AHr Battery. User Manual

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

Motorized Stainless 2-Way Valves

30A SMART ENERGY MANAGEMENT SYSTEM TM

EC-3000/3400 Solid State Rotary Cam Limit Switch Installation/Operation Manual

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

A419ABG-3C Electronic Temperature Control

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

VERTIV XTE 401 SERIES. Ordering Guide

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Installation Manual & Warranty

SBP2 Pendant Pushbutton Stations Installation Instructions

C Power Connection Kit

Installation Manual for VMAC Throttle Commander Throttle Control T500111

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

TRAC-Station BT Installation Instructions

Assembly Instructions Signature Choral Riser 3-Step Model

Installation Instructions for Eaton Surge Protective

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

ADI-125/750 ADI-125/1500 ADI-125/2500

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives

MA40-704X Series MA41-707X Series MA41-715X Series

Electric Vehicle Charging Station

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Transcription:

Lighting Control Unit Installation Instructions DOC. #560066000 A 7/30/04 PRINTED IN U.S.A.

Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL 916, Energy Management Equipment, and is listed by Underwriters Laboratories, Inc., for installations in the United States. This device has been tested and found to be in compliance with the requirements set forth in C22.2, No. 205-M1983, Signal Equipment, and is Certified by Underwriters Laboratories, Inc., for installations in Canada. Disclaimer Logic One is a registered trademark of Novar Controls Corporation. The material in this manual is for information purposes only. The contents and the product it describes are subject to change without notice. Novar Controls Corporation makes no representations or warranties with respect to this manual. In no event shall Novar Controls Corporation be liable for technical or editorial omissions or mistakes in this manual, nor shall it be liable for any damages, direct or incidental, arising out of or related to the use of this manual. Copyright 2004 by Novar Controls Corporation. All rights reserved. No part of this manual may be reproduced in any form or by any means without prior written permission from Novar Controls Corporation. Novar Controls Corporation 6060 Rockside Woods Blvd., Cleveland, OH 44131 Tel: 800.348.1235 www.novarcontrols.com

Description Novar Controls Corporation s Lighting Control Unit (LCU; Figure 1) is a unique, cost-effective, and versatile means of controlling lighting. Its design includes fail-safe operation. It can be controlled by the Logic One Input/Output Module (IOM/2). These instructions describe the procedure for connecting the input device as an IOM/2. The LCU uses RR-7 mechanically latching relays (not included) for individual circuit control. The LCU electronics are powered by a 24-VAC power supply. Figure 1. Lighting Control Unit Novar Controls offers two models of the LCU. (These instructions apply to both.) LCU-1010 (277-VAC) LCU-1012 (120-VAC) Specifications Agency Approvals Listed device: Standards used: Control Power Requirements Voltage: Consumption: Operating Environment Temperature: Humidity: Physical Dimensions Height: Width: Depth: Weight: CUL/UL E90949 UL 916, Energy Management Equipment CSA C22.2, No. 205-M1983, Signal Equipment 277-VAC (model LCU-1010) 120-VAC (model LCU-1012) 40 VA 32 to 158F(0 to 70C) 0 to 95% Relative, noncondensing 30 inches 20 inches 6.875 inches 56 lb Doc. #560066000 A 7/30/04 1

Precautions Take the following precautions during installation: Observe all national and local electrical codes during installation. Observe warning labels marked on the Lighting Control Module terminal strip. Do not connect Class 1 voltages to any terminal of the LCU electronics or to the matrix board. The LCU electronics is a Class 2 (low voltage) control device. The LCU s outputs are fed into the matrix board and are low voltage. Use Model RR-7 latching relays only. The use of any other relays may cause damage to the relays or the LCU. Do not exceed the LCU s limit of 56 RR-7 relays per LCU. Mounting the LCU Enclosure Because LCUs control high voltages, they should be mounted according to local governing electrical codes. The maximum ambient temperature should be 158F. The LCU s enclosure is not weatherproof. The LCU enclosure must be mounted securely to an approved mounting surface. Use the following procedure and refer to Figure 2, as necessary, to mount the LCU enclosure. Step Procedure 1 Turn off all power to the LCU and the associated equipment prior to installation. 2 Mark the mounting surface to show the location of the four mounting holes (see measurements in Figure 2). 3 Drill holes in the locations marked in Step 2. 4 Turn the top two fasteners (not included) until approximately one-quarter inch remains between the mounting surface and the head of the fasteners. 5 Position the enclosure over the fasteners and slide it down until the fasteners slide into the slots. 6 Insert the bottom two fasteners and tighten all four fasteners to secure the enclosure. 2 Doc. #560066000 A 7/30/04

Figure 2. Mounting holes for the LCU The power supply for the electronics transformer should be of the transformer primary rating. Do not connect power until all wiring connections are made and verified. Installing and Wiring the RR-7 Relays Before installing and wiring the RR-7 relays, verify the RR-7 ratings for the voltage and amperage being controlled. The RR-7 relays should be mounted with banana plugs installed on all three leads. The circuits being controlled must dictate the size and voltage rating of the wire used. Copper wire is recommended. Use the following procedure and refer to Figure 3, as necessary, to wire the relays. Step Procedure 1 Strip approximately an inch of wire and insert the lead through the opening in the plug, making sure that the insulated portion shows through the other side. 2 Wrap the lead clockwise around the groove above the opening. 3 Place the plastic cap over the plug and tighten it until it covers the exposed wire. Make sure that all wire connections made with banana plugs are tight and that no wire strands are exposed. continued Doc. #560066000 A 7/30/04 3

Step Procedure 4 Plug the common (blue) leads into the outer (left/right) female receptacles on the matrix board. 5 Plug the on (red) leads into the desired schedule on female receptacles. 6 Plug the off (black) leads into the same schedule off female receptacles. No Class 1 wiring should enter the Class 2 compartment. No Class 2 wiring should enter the Class 1 compartment unless properly insulated. Figure 4 shows a typical wiring diagram and the location of the Class 1 and Class 2 compartments. 7 Turn off the breaker(s) or circuit(s) being controlled. 8 Route the wire through the RR-7 relay and back to its source and label each wire individually with the breaker number. Figure 3. Wiring the banana plug relays Once 24-VAC power is connected to the LCU electronics, the LCU pulses all properly wired RR-7s to the fail-safe (on or closed) position. For information about connecting power, see Installing the LCU Electronics Transformer in this document. If an LCU has fifty-six RR-7 relays (the maximum limit), it may take more than one pulse to change all of the RR-7s to the proper state. Pulses occur every 32 seconds. 4 Doc. #560066000 A 7/30/04

Figure 4. Typical Wiring Diagram for LCU Doc. #560066000 A 7/30/04 5

Wiring the IOM Outputs to the LCU Terminal Strip All control schedule wiring must meet national/local codes. Refer to Figure 4 for the location of the Class 1 and Class 2 wiring compartments. The control schedule wiring must be Class 2, low voltage, 18- to 20-gauge solid or stranded cable. If using all eight schedule groups, a 10-conductor wire is recommended. Make sure that the Class 2 wiring does not interfere with removing the LCU electronics. If holes are punched in the top of the LCU for wiring, they should not be directly above the LCU electronics. Determine the total number of schedules provided/required (8 maximum). Input devices should be Class 2 contacts, 24-VAC. A supply transformer must be provided at the IOM. Connect one side of the transformer to one side of the IOM outputs. Connect the other (common) side of the transformer to Terminal 9 (COM; see Figure 5) on all LCUs. Figure 5. LCU Terminal Strip Each IOM output should be connected to a respective terminal on all LCUs. IOM output wiring can be wired in parallel to multiple LCUs. If the matrix board is becoming full, the banana plugs can be wired in tandem to make it easier to insert them on a loaded LCU. 6 Doc. #560066000 A 7/30/04

Installing the LCU Electronics Transformer The 24-VAC transformer that powers the LCU electronics comes in a separate package and must be mounted in the LCU during installation. Use the following procedure and refer to Figure 6, as necessary, to install the LCU electronics transformer. Step Procedure 1 Thread the two wires located on the primary side of the electronics transformer through the hole provided in the wall on the right side of the LCU electronics and connect them to 120-VAC or 277-VAC, as required. 2 Tighten the locknut on the 277-VAC transformer until the transformer is held firmly in place in the hole. The 120-VAC transformer is connected to the hole using a different method. Instructions for making this connection are packaged with the transformer. 3 Connect two wires from the 24-VAC secondary side to the terminals labeled 24-VAC, 40 VA, Class 2 on the electronics. Figure 6. LCU transformer installation Doc. #560066000 A 7/30/04 7

Checking Operation When the installation has been completed, the following items should be checked to verify that the LCU is operating properly. Turn on power to the LCU. With all IOM output contacts open, the LCU should pulse all RR-7s closed, enabling all lighting to be on. There should not be any voltage present when reading across LCU Terminals 18 to COM (Terminal 9). If the lights are not on, verify 24-VAC on Terminals 10 11 (24-VA electronics power). Close IOM Output #1. Verify 24-VAC from Terminal 1 (Schedule 1) on the LCU to Terminal 9 (COM). The LCU should pulse the RR-7 relays to the open (off) state within 32 seconds. Repeat this test for all schedules provided. Open input device Schedule 1. Verify the absence of voltage on the LCU Terminal 1 and Terminal 9 (COM). The LCU should pulse the RR-7s to the closed (on) state. Repeat this test for all schedules provided. To provide fail-safe operation (lights fail on), the output activated state of the software should be set to off at the IOM Control Settings and Parameters screen in the software. Model and Part Numbers Use the part numbers provided in Table 1 to order the necessary Novar Controls parts. Table 1. Novar Controls Part Numbers PRODUCT MODEL NO. PART NO. Lighting Control Unit (277-VAC) LCU-1010 731000000 Lighting Control Unit (120-VAC) LCU-1012 731002000 Lighting Control Relays RR-7 731060000 Banana Plugs for RR-7 Relays LCU-PLG 731050000 8 Doc. #560066000 A 7/30/04