Cable Temperature QAP... Sensor. Use

Similar documents
Immersion temperature sensor QAE26.9.

Electromotoric Actuators

Electromotoric Actuators

Differential pressure sensor

Condensation monitor

Actuators for Fire and Smoke Protection Dampers

Differential Pressure Sensors

Electromotoric actuators

Power supply (70 W) Sinteso / Cerberus PRO FP2015-A1

Actuators for Fire and Smoke Protection Dampers

Differential Pressure Switch QBM81-

Rotary actuators for ball valves

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

2-Port and 3-Port Zone Valves PN 16

Differential Pressure Sensors

Three-port slipper valves PN10, female-threaded

ACVATIX MiniCombiValves (MCV)

SSA955. Synco living Radiator Control Actuator

Power supply kit (70 W)

VPI45..Q with pressure test points. Combi valves, PN 25

2- and 3-port valves with flanged connections, PN 16

Pressure Sensors. for liquid and gaseous media

2-port and 3-port terminal unit valves PN16

2- and 3-port valves with flanged connections, PN 6

2- and 3-port valves with flanged connections, PN 25

Electromotoric Actuators

Differential Pressure Switch QBM81-

2-port shutoff valves and 3-port changeover ball valves, PN 40, with internally threaded connection

Screw-in resistance thermometers. Connecting cable. Technical data. Data Sheet Page 1/5

Insertion thermometer With connection lead Model TF45

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V

Modulating Control Valve PN 16 with Magnetic Actuator

Temperature Controller (Heat Pumps)

Float switch For industrial applications, with temperature output Model RLS-3000

Actuators for air and gas dampers

Differential-Pressure Flow Meter

Modulating control valves with magnetic actuators, PN 16

Modulating control valves with magnetic actuator PN 16

Modulating control valve with magnetic actuator PN16

THERMASGARD TF 43 THERMASGARD TF 65

Actuators for small valves

Actuators for Air and Gas Dampers

Differential Temperature Controller

Electromotoric Actuators

Gas Pressure Governors

Push-in RTD Temperature Probe with Connecting Cable

Actuators. Building Technologies Division

Temperature sensors. and accessories for heat and cooling measurement points. Applications. Benefits. Features

Design and applications

Electromotoric actuators

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

Resistance thermometer with digital display Model TR75, battery operation

2-Port and 3-Port Zone Valves, PN 16 / 20

Electromagnetic Flow Monitor magphant

Design and application

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

Actuators for Air and Gas Dampers

Differential Pressure Sensors

Surface thermocouple Model TC50

Electromotoric Actuators

2- and 3- port valves with flanged connections, PN 16

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Electromotoric Actuators

2-Port and 3-Port Zone Valves & Actuators, PN16

ABB Instrumentation. Noflote designed for control of conductive liquids. Reliable on/off liquid level control for alarms or pump control

Screw-in thermometer with connection lead Model TF37

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

Electrohydraulic actuators for valves

KombiTemp. Head form B / Head form J Cable socket, angle type Diesel engine dial thermometers. Temperature Sensors with local display

Conductivity Measurement CLM 280

Electrohydraulic actuators for valves

TS Temperature Sensor and Transducers. Product Bulletin. Wide range of mounting types and signal outputs

Modulating control valves with magnetic actuator PN 16

2-Port and 3-Port Zone Valves, PN16

M-bus impeller type heat and heat/refrigeration meters

UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Mechatronic pressure measurement. Applications. Special features. Description

Heating Cost Allocation Valve with local acquisition of the flow temperature

MWF+ Application. Types Available. Average temperature sensor. Datasheet

Duct thermometer Model TF40

Modulating control valve PN16 with magnetic actuator

Electro-hydraulic actuators for valves

Cable resistance thermometer Model TR40

VPP46.. Combi valves, PN 25 VPP46..Q VPI46.. VPI46..Q ACVATIX. for rooms, zones, ventilation and air-conditioning systems

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

VPI45..Q with pressure test points. Combi valves, PN 25

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Electrical Actuators

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

ATEX/IECEx RTD temperature probe

Electromotoric Actuators. for zone valves VVI46.., VXI46.., VVS46.. and VXS46..

Inductive conductivity meter

Transcription:

1 831 1847P01 Cable Temperature Sensors QAP... Use The sensors are used in heating, ventilation and air conditioning plants to acquire the temperature. They are for use with the corresponding accessories as: strap-on sensors for pipework strap-on sensors for solar collectors immersion sensors Changeover (from heating to cooling or vice versa) Type summary Type reference Sensor element Cable length Material connecting cable Measuring range Weight (incl. packaging) QAP2010.150 Pt 100 1,5 m silicone -30 +130 C 0,05 kg QAP2012.150 Pt 1000 1,5 m silicone -30 +130 C 0,05 kg QAP21.3 LG-Ni 1000 1,5 m silicone -30 +130 C 0,05 kg QAP21.3/8000 LG-Ni 1000 8 m silicone -30 +130 C 0,23 kg QAP22 LG-Ni 1000 2 m PVC -25 + 95 C 0,06 kg QAP1030.200 NTC 10k 2 m PVC -25 + 95 C 0,06 kg CE1N1831en 2017-12-01 Building Technologies

Accessories Name Part number/ type reference Protection pocket, Ms63, PN10, immersion length 100 mm ALT-SB100 1) Cable holder for protection pocket mounting 4 213 1416 0 Changeover mounting kit For fitting on pipes (pipes of about 13...35 mm dia.), consisting of holding piece and cable ties (2x) Aluminium bar Consisting of bar with riveted holder and rubber grommet ARG22.1 2) ARG22.2 1) For other protection pocket accessories, refer to Data Sheet N1194. 2) Suited for max. 95 C. Use cable ties made of metal for temperatures above 95 C Ordering and delivery When ordering, please give type reference of sensor and part numbers / type reference of the accessories required. Example: Cable temperature sensor QAP2010.150. The cable temperature sensor is supplied without any mounting accessories. These must be ordered separately. Equipment combinations The cable temperature sensors are suited for use with all types of controllers that can handle the sensor s passive output signal. Function The sensor acquires the temperature via its sensing element. The resistance of the sensing element changes as a function of the ambient temperature. The resistance value is used for further handling by a suitable controller. Sensing elements LG-Ni 1000 Characteristic: Accuracy: R [] [K] 1800 1801D01 1.5 1801D02 1600 1.0 1400 0.5 1200 1000 0.5 800 1.0 600 1.5 40 30 20 10 0 10 20 30 40 50 60 70 80 40 30 20 10 0 10 20 30 40 50 60 70 80 2/6

Pt 100 (class B) Characteristic: Accuracy: R [] 160 1847D01 0.8 [K] 1847D02 140 0.4 120 100 0.4 80 40 30 20 10 0 10 20 30 40 50 60 70 80 0.8 40 30 20 10 0 10 20 30 40 50 60 70 80 Pt 1000 (class B) Characteristic: Accuracy: R [] [K] 1600 1400 1847D05 5.0 4.0 3.0 2.0 1.0 1847D04 1200 1.0 1000 2.0 3.0 800 40 30 20 10 0 10 20 30 40 50 60 70 80 4.0 5.0 30 20 10 0 10 20 30 40 50 60 70 80 NTC 10k Characteristic: Accuracy R [] 1000000 100000 10000 1000 100-30 -20-10 0 10 20 30 40 50 60 70 80 1847D09 [K] 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6-1.8-30 -20-10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 1847D08 [ C] Legend R Resistance in Ohm Temperature in degrees Celsius 3/5

Mechanical design The sensor consists of sleeve (40.5 mm in length), sensing element and 2-core connecting cable. The sensing element is encapsulated in the sleeve so that it is mechanically and electrically protected. The sleeve also ensures strain relief for the connecting cable. The end of the cable carries ferrules for easy connection. Different accessories are available for fixing the sensor. Engineering notes Mounting and installation notes The permissible cable lengths are dependent on the type of controller with which the sensor is used. They are specified in the Data Sheet of the relevant controller. The connecting cable should always be connected to a conduit box. When mounted in a protection pocket, the sensor must always be fixed in the pocket by means of the cable holder. Instructions for mounting in induction or fan coil units: The sensor should be fitted in the location specified by the manufacturer of the terminal unit. If there is no such specification, it must be fitted in the return air flow where it captures the temperature of the room air drawn in. It should be fitted as high as possible to minimize the floor effect. The sensor must be protected against heat radiation from the terminal unit. Disposal The device is considered electrical and electronic equipment for disposal in terms of the applicable European Directive and may not be disposed of as domestic garbage. Dispose of the device via the channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 4/6

Technical data Functional data Degree of protection Electrical connections Environmental conditions Environmental compatibility Materials Weight Measuring range Sensing element Time constant Sensor with ARG22.1 (attached to pipe) approx. 25 s Sensor with protection pocket <30 s Sensor with ARG22.2 in air at v = 3 m/s <1 min Measurement accuracy refer to "Function" Type of measurement and output passive Protection degree of housing IP65 according to EN 60529 Protection class III according to EN 60730-1 Connecting cable Cross-sectional area Length Perm. cable lengths Permissible ambient temperature for silicone cables for PVC cables 2-core, interchangeable 2 x 0.34 mm 2 see "Type summary" refer to "Engineering notes" 30...140 C 25...+95 C, Short-time (2 h/d) +110 C Perm. ambient humidity 95 % r. h. EU conformity (CE) 8000073890 *) The product environmental declaration CE1E1701 *) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Sensor sleeve stainless steel 1.4571 (V4A) Connecting cables Packaging corrugated cardboard Incl. packaging *) The documents can be downloaded from http://siemens.com/bt/download. 5/5

Internal diagram 1847G01 The internal diagram is identical for all types of cable temperature sensors covered by this Data Sheet. The connecting wires are interchangeable. Dimensions Sensor QAP Protection pocket ALT-SB100 Changeover mounting kit for fitting on pipes ARG22.1 Aluminium bar ARG22.2 12 40,5 30 13 100 13 22 130 6,5 7 x 10 10 5 5,3 ø 6 1831M06 G½ A ø 9 1832M04 22 2 2 16 1831M05 Dimension in mm Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 58-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2014 Delivery and technical specifications subject to change 6/6