WILO NR series Stainless Submersibles

Similar documents
Wilo TWI & TWU 4 Submersible Well Pumps Installation and operating instructions

Operating Instructions

Wilo-Control SC-Fire Jockey

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

Pneumatic Single Disc and Dual Disc Brakes P250 and P620

Instrucciones de instalación y funcionamiento Installation and operating instructions

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

Assembly and Maintenance Manual Type AS

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

Assembly and Maintenance Manual Type RSBW

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Assembly and Maintenance Manual Type ASNU

SUBMERSIBLE WATER PUMPS

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Hydraulic Multi-Disc Brake H420 P-2067-WE SM320gb - rev 02/09

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

SUBMERSIBLE WATER PUMP

Series description: Wilo-Sub TWI 6-..-B

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

M Series Condensate Recovery Unit

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

corso beam clamps operating and maintenance instructions Beam Clamps: 1 ton 2 ton 3 ton 5 ton 10 ton equipment in accordance with CE directives

FLENDER BIPEX couplings. Types BWN, BWT and BNT. Operating instructions BA 3400 EN 01/2012. FLENDER couplings

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

Wilo-SiFire Easy. Pioneering for You. de en. Einbau- und Betriebsanleitung Installation and operating instructions

Operating Instructions

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015.

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

StormPro BA Series Sump Pump

original operating manual Operating manual Translation of the Item-No.: ,

BoWex FLE-PA. BoWex FLE-PAC. KTR-N Sheet: Edition: EN 1 of BoWex FLE-PA / FLE-PAC Operating/Assembly instructions

Installation, Care and maintenance

Operating manual. ba55321de LRD Conductivity measuring cell to be installed in pipelines. ba55321de01 12/00

Operating manual Separator

Product Information Overspeed governor GB 260

These installation and maintenance instructions must be read in full and completely understood before the installation!

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Operation manual Flexible pin type coupling according to KWN 22014

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

Submersible waste water pumps. Installation and operating instructions Series: DVV

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

ZB0050 / ZB0051 ZB0070 / ZB0071

Instruction Manual. Sewage lifting station compli 300

Oil-free piston compressors KK and piston vacuum pumps KV

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

FLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings

SUBMERSIBLE PUMP HSE RANGE

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

HUNTER PUMPS ELECTRIC FIRE PUMP SET

IP 900 W/KS & IP 900 D/KS

Operating manual. Custom made gearboxes

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

INDECO LUBEMAXX. Operating and Assembly Manual INDECO LUBEMAXX

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Pressure relief valve

Owners Manual: - Pumps

OWNER S MANUAL. Evolution Series Fountain. 1/2 hp, 115V, 60 Hz

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

CENTAX-TEST Assembly and operating instructions 053C GB3. M EN Rev. 1

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Ama-Drainer N 301/302/303

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

UNIPUMP. Operating Instructions. Close Coupled Sewage pump Series K, HK, QSH. Internet

Swing Piston Compressors and Vacuum Pumps

Operating manual Vacuum Breaker

Operating and installation instructions

CRD600 Automatic Fitting Inserter

SUBMERSIBLE PUMP HSE RANGE

Unified requirements for systems with voltages above 1 kv up to 15 kv

FLENDER UZWN overrunning clutches with FLENDER KSUN clutch shift. Types UZWN and KSUN. Operating instructions BA 3001 en 06/2012.

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Operating instructions

Installation and Maintenance Manual

Operation Manual Flexible Claw couplings according to KWN 22013

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

OWNER'S MANUAL. FS/FT Series - Borehole Pumps PURPOSE OF THIS MANUAL STANDARD REFERENCES SAFETY INTRODUCTION. Symbology

June14. Type

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

KeContact P20. User manual

OPERATING INSTRUCTION UPS PROTECT A. PROTECT A PROTECT A. 1400

HST -LS Interlocking device (Translation of Original Manual)

Operating Instructions Ball Valves

Rio-Therm N. Installation/Operating Manual

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

CENTAX-SEC Series B Assembly and operating instructions CX BFS1-LE/SE-**-B M EN Rev. 1

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

IMMERSON D 4. 4 BOREHOLE PUMPS 2 pole - 50 Hz APPLICATIONS. AdVANTAGES. Flow rates up to: 24m 3 /h Head up to:

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

Internal Gear Pumps Installation Manual

Instruction Manual. * We reserve the right to amend specification without prior notice.

Original Operating Manual

Transcription:

Installation and Operating Instructions NR 4-6-8 05.23.06 WILO NR 4-6 - 8 series Stainless Submersibles Subject to technical changes!

Contents: 1 General Information 1.1 Uses 1.2 Technical characteristics 2 Safety 3 Transport and interim storage 4 Product and accessory description 4.1 Description 4.2 Pump 4.3 Motor 4.4 Accessories 5 Assembly / Installation 5.1 Assembly 5.2 Hydraulic connection 5.3 Electrical connection 6 Operation 6.1 Controlling the direction of rotation: 6.2 Operation 7 Maintenance 8 Problems, Causes and Solutions

1 General Information Installation and service by qualified personnel only! 1.1. Uses Submersible pumps of the NR series are suitable for drawing groundwater from deep wells, for industrial use and for supplying water. 1.2 Product data 1.2.1Rating plate NR 6 30-3 Submersible motor pump Nominal pump diameter Min. bore-hole diameter = 4 /6"/8" Nominal volume flow Q (gpm) x 10 Number of stages 1.2.2Technical characteristics Temperature range: +37 F (3 C) to +86 F (30 C) Max. Flow rate: 1320 [gpm] Max. immersion depth: 1148 ft Maximum permissible sand content 50 g/m 3 Pressure pipe connection: 2" to 6", depending on size of pump Max. pump lift: 650 ft to 1300 ft, depending on size of pump 2 Safety These instructions contain important information which must be followed when installing and operating the pump. These operating instructions must therefore be read before assembly and commissioning by the installer and the responsible operator. Both the general safety instructions in the Safety precautions section and those in subsequent sections indicated by danger symbols should be carefully observed. 2.1 Danger symbols used in these operating instructions Safety precautions in these operating instructions which, if not followed, could cause personal injury are indicated by the symbol:, when warning of electrical voltage with The following symbol is used to indicate that by ignoring the relevant safety instructions, damage could be caused to the pump/machinery and its functions: ATTENTION! 2.2 Staff training The personnel installing the pump must have the appropriate qualifications for this work.

2.3 Risks incurred by failure to comply with the safety precautions Failure to comply with the safety precautions could result in personal injury or damage to the pump or installation. Failure to comply with the safety precautions could also invalidate any claims for damages. In particular, lack of care may lead to problems such as: Failure of important pump or machinery functions, Personal injury due to electrical, mechanical and bacteriological causes. Damage to property. 2.4 Safety precautions for the operator Existing regulations for the prevention of accidents must be followed. Dangers caused by electrical energy are to be excluded. Directives issued by the local electrical code and the local electricity supply companies are to be observed. 2.5 Safety information for inspection and assembly The operator must ensure that all inspection and installation work is carried out by authorised and qualified specialists who have carefully studied these instructions. Work on the pump/machinery should only be carried out when the machine has been brought to a standstill. 2.6 Unauthorized modification and manufacture of spare parts Alterations to the pump or installation may only be carried out with the manufacturer's consent. The use of original spare parts and accessories authorised by the manufacturer will ensure safety. The use of any other parts may invalidate claims invoking the liability of the manufacturer for any consequences. 2.7 Unauthorized operating methods The operating safety of the pump or installation supplied can only be guaranteed if it is used in accordance with paragraph 1 of the operating instructions. The limiting values given in the catalogue or data sheet must neither be exceeded nor allowed to fall below those specified. 3 Transport and interim storage Upon delivery, please check that the device has survived the journey undamaged. If you find any damage, the normal routine measures are to be initiated with the shipping company. ATTENTION! During transport and in storage the pump must be protected against moisture, frost and mechanical damage. Store horizontally in shockproof places. 4 Product and accessory description 4.1.Description (see fig. 1) 1 Pump Wilo-Sub 4"/6"/8" 9 Mains connection/power supply 2 Immerson electrode mass 10 Manometer 3 Low-water immerson electrode (off) 11 Pressure vessel/reservoir 4 Immerson electrode upper level (on) 12 Shut-off valve 5 Connecting extension cable 13 Non-return valve 6 Dynamic level (pump running) 14 Motor connecting cable 7 Static level (pump switched off) 15 Cable connection between pos. 14 and pos. 5 8 Switch box (with dry-run protection)

4.2. Pump Multistage submersible pump with radial or semi-axial impellers, depending on size of pump, for use in 4", 6" and 8" bore-holes. with built-in check valve. 4.3. Motor Consult motor manufacturer s documentation for more information. 4.4. Accessories Accessories must be ordered separately. Switching/controlling equipment (motor protection + pump control) pressure switch assembly sensor assembly pressure reducer float-/diaphragm valve check valve shut-off valves manometer safety valve dry-run protection device immerson electrodes float switch motor cable as assembly (incl. plug) or piece goods (without plug) heat-shrink cable connections steel cable (stainless steel) diaphragm pressure vessel cooling-shroud (stainless steel/pvc) plug sets for cable connection etc. 5 Assembly / Installation The pump can be operated either vertically or horizontally (for horizontal position only with a cooling-shroud). However, in the case of horizontal installation the number of stages is limited, depending on size of pump: Type of pump Max. stages NR 6-12.. 22 NR 6-18.. 18 NR 6-24.. 15 NR 6-35.. 12 NR 6-45.. 8 NR 8-42.. 14 NR 8-80.. 12 NR 8-100.. 8 NR 10-170.. 6 NR 10-250.. 4

ATTENTION! The maximum flows must be respected. Beyond maximum there is risk of damage to the motor. Type of pump max. flow gpm NR 6-12.. 70 NR 6-18.. 114 NR 6-24.. 154 NR 6-35.. 216 NR 6-45.. 348 NR 8-42.. 286 NR 8-80.. 506 NR 8-100.. 598 NR 10-170.. 1056 NR 10-250.. 1320 5.1 Assembly The bore-holes or pump stations must be created/arranged in accordance with the generally applicable technical rules. Please ensure that the flow of water in the bore-hole or well is sufficient for the capacity of the pump. The pump is carefully lowered using a double-purchase pulley on the suspension rope and tripod/crane, heavy pumps using a rope winch. Ensure that the pump never runs dry and make sure that even in dry periods the water level never falls below the pump s check valve (uppermost position). ATTENTION! In the case of installation in a deep well (well shaft diameter greater than a bore-hole), a reservoir, horizontal installation or in a deep well, a cooling-shroud (accessory) must be fitted to the unit to ensure the motor is properly cooled (fig. 2, pos. A). It must be ensured that the well shaft in the bore-hole has a constant internal diameter to allow the pump to be lowered freely for the entire depth of the shaft. Never raise or lower the pump by the electric cable. The electrical connection and extension of the motor cable must take place before the pump is lowered and be tested/measured to ensure they are working. The final installation position must be guaranteed such that the pump sits at least 1 foot above the bottom of the bore-hole or well (fig. 1). The rating plate must be affixed in the immediate vicinity of the well head to allow access at all times to the unit s technical data. Before lowering (and while lowering in deep bore-holes) the insulation resistance of the motor and cable must be measured several times (min. 2 M ). 5.2 Hydraulic connections (see fig. 1) Connections to steel threaded pipes: 2" or 2 ½", 3", 4", 5", 6" depending on size of pump. If flexible pipework is used, the pump must be held by a chain/steel cable. The two steel loops on the pump head are to be used for this.

In the case of larger types (8" / 10"), the pump is only connected directly to the pipework. It is recommended that a check valve be fitted on the pressure side of the pump (between the ascending pipe in the bore-hole and the above-ground pipe installation) at the well head. A manometer, pressure switch/gauge and a shut-off valve are to be installed at the head of the bore-hole/well. 5.3 Electrical connection Electrical work must be carried out by a qualified and licensed electrician in strict compliance with local regulations. The maximum cable length depends on the nominal motor current and the permissible drop in voltage over the entire cable length. Consult motor manufacturer s documentation for more information.

ATTENTION! A faulty electrical connection will result in damage to the motor. 6. Operation 6.1 Controlling the direction of rotation: To determine the correct direction of rotation for the pump, only the shutoff pressure at the well head needs to be checked, taking into account that the correct motor direction of rotation generates the greater pressure. To rectify an incorrect direction of rotation swap any two phases in the switchbox or motor protection switch. See motor manufacturer s documentation for more information. 6.2 Operation ATTENTION! The pump must never run while dry, not even for brief periods. ATTENTION! Please note that not respecting this information may lead to premature motor failure and or reduced life expectancy! 7 Maintenance Before carrying out any maintenance work, switch off the pump and ensure that it cannot be switched on again by unauthorized people. Never carry out work on a running pump. No special maintenance is required during normal operation. 7.1 Spare parts Please contact Wilo Customer Service directly for spare parts, standard replacements or repairs to the hydraulic pump parts.

8 Problems, Causes and Solutions Problems Causes Solutions The motor does not run No or insufficient capacity Pump switches on too frequently a)voltage too low b)suction filter blocked c)incorrect motor direction of rotation d)low-water protection or water level in well too low a)insufficient switching difference between on/off pressure in pressure switch/gauge Consult motor manufacturer s documentation for trouble shooting tips. a) Check electrical power supply at switchgear. b) Lift pump out of bore-hole, clean suction filter. c) Swap any two phases in the switchgear. d) Check water level in bore-hole/well; it must be at least 8 (20 if 8 motor) above the pump pressure-pipe connection (during operation). a) Increase difference between on and off points b)incorrect arrangement of immerson electrodes. c)storage volume of diaphragm pressure vessel too small or prepressure setting too low b) Increase gaps between immerson electrodes and thus regulate switching times. c) Check switching pressure settings and reset Check vessel prepressure (no water in vessel) Provide additional pressure vessel or install tank with greater nominal volume. If the fault cannot be remedied, please contact WILO customer services. Subject to technical alterations!

Fig. 1 Refer to clause 4.1