FILTER TESTING FOR AIR FILTER AND MEDIA EFFICIENCY MEASUREMENT

Similar documents
WM 07 Conference, February 25 March 1, 2007, Tucson, AZ. Evaluation of Glass Fiber Hepa Filters as a Function of Media Velocity

CONTAMINATION CONTROL FOR LIFE SCIENCE APPLICATIONS

Splash-proof Terminal HEPA Filter

CERTITEST Model 3160 Automated Filter Tester

nivia utilities Why Air Filters???

Compact Finedust / HEPA Filter

AVL Particle Measurement System Aviation

Panel Finedust/HEPA Filter

where nature and technology meet FILTRATION Solutions for filtration applications PETROGAS GAS-SYSTEMS BV

MODEL RPM10/RPM20 (-LON)/RPM20-CC PRESSURA ROOM PRESSURE MONITOR

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Lecture 3 : Cleanroom Technology (Contamination Control)

FEATURES AND BENEFITS

Model 8026 Particle Generator

Test procedure and Specifications for Particle Number Portable Emissions Measurement Systems (PN-PEMS)

Case Study: Design of a Calibration Reference Device for ANSI/ASHRAE Standard ME 4054W November 16, 2010 T. H. Kuehn SCREEN CONCEPTS

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

The reference in sandblasting. DCM\DCM 3000 a DCM to series.

mass flowmeter for compressed air

Silver Series Thermal Dispersion Airflow Measurement Technology

DATUM ELECTRONICS RS425 NON-CONTACT TORQUE TRANSDUCER PRODUCT OVERVIEW

PROHOOD AIR CAPTURE HOOD MODEL PH731

AstroCel. Better Air is Our Business ss. High Efficiency Particulate Air Filters (HEPA) Ultra Low Penetration Air Filters (ULPA)

MODEL 8635 SUREFLOW ROOM PRESSURE MONITOR

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Dekati Solutions. Engine Emissions

FlowAir CATALOG.

Mobile recleanable HEPA filter units for a flow of m 3 / h

PERFORMANCE TEST OF CONICAL/CYLINDRICAL GAS TURBINE CARTRIDGES FOR GENERAL VENTILATION APPLICATIONS

PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS. The Complete Plug-and-Play Solution

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371

mass flowmeter for compressed air

TSI PTI-Prototype for PN- Periodic Technical Inspection

JG, JK, JP Ultrafilter

PIV ON THE FLOW IN A CATALYTIC CONVERTER

Superstatic 440. Static Heat- and Cooling Meter. Application

For reliable control of small, large or multi-system-type lubrication systems

WB 23 & WB 27. High-Speed Eddy-Current Dynamometers WB 23 & WB 27. Features. Description. Operating principles

Infinite F50 family INNOVATIVE EIGHT CHANNEL ABSORBANCE READERS WITH ADVANCED LED TECHNOLOGY. 21 CFR Part 11* 98/79/EC IVD-D*

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Model 8026 Particle Generator

FIRST FOR PORTABLE PARTICLE COUNTING

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Air pollution control

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

Infinite F50 family Reliable. Validated. Compact.

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER

Excellence in gas analyzers since Over 180 years of JY optical experience. The expertise of Horiba combustion technology

MODEL 8630 PRESSURA ROOM PRESSURE MONITOR

Range of Ultrasonic Flowmeters.

Dryflo Mist Collectors

LEDGELESS VERTICAL CARTRIDGE DUST COLLECTOR

Full power Cyclone precleaner technology when the going gets dusty

Instruments and sensors for Periodic Technical Inspection (PTI) with DPF-equipped vehicles and Kerbside Control

1291BL Series Technical Specification Single Axis Position and Rate Table System

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

Linear-Transducer LMP48 - A

Design Makes All The Difference...

Content 1. Laserline series 3

Cyclic Corrosion Chamber C.C.T AUTO Series

Ventilation Control. Ventilation Control 12

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Miniature Proportional Valves Precision Fluidics

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Optidew Vision Optical Dew-Point Meter

Safety drying ovens. Advantages: Areas of application: FDL series 115

STANDARD TRAVERSE SYSTEMS FOR LDV, PDPA AND PIV

AvCount Laser Particle Counters

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

MODEL 8636 / 8636-LN / 8636-BAC SUREFLOW ROOM PRESSURE CONTROLLER

Rosemount Orifice Series Differential Pressure Flow

Tventilation and recirculated air used for conditioning building

2. provide data indicating what types and sizes of particles are not removed by used PHEAF devices, and

Low cost EDXRF elemental analyzer

MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER

Steering Test Rigs. The World of Steering Test Machines. A world of experience TEST AND MOTION SIMULATION 2

Sentronic PLUS 614 Series

Class I Microbiological Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet

External gear motor High Performance AZMB

SUREAL-23 UNDERSTANDING, MEASURING AND REGULATING SUB-23 NM PARTICLE EMISSIONS FROM DIRECT INJECTION ENGINES INCLUDING REAL DRIVING CONDITIONS

Test-A-Pack Seal Strength Tester F The most important thing we build is trust. Testing Range. Key Features. Ordering Information

INSERTION flowmeter with paddle wheel, ELEMENT design

Dependence of particle size distribution on injection pressure

Safety drying ovens with expanded temperature range

Safety drying oven with expended temperature range

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Paddle-wheel flow controller with optical principle for On/Off control

Johnson Controls Rooftop Units

Effectiveness of Cabs for Dust and Silica Control on Mobile Mining Equipment

Differential Pressure Sensors

LADO FILTER ENGINEERING

MagFlux Q 8200 Series

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Certificate: TNU112UML0348/ Test report: 112UML0348 / of 14 January 2013

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Transcription:

FILTER TESTING FOR AIR FILTER AND MEDIA EFFICIENCY MEASUREMENT UNDERSTANDING, ACCELERATED

TRUSTED BY FILTER MANUFACTURERS AROUND THE GLOBE TSI has automated filter testers (AFTs) and components that can be used for filter testing and are used to comply with various testing standards and regulations around the globe. TSI AFTs are designed for measuring filtration efficiencies of media and a variety of air filters, including very high-efficiency filters, respiratory filters, cartridges, and protective garments using submicron poly- and monodisperse oil and/or sodium chloride aerosol. TSI AFTs have proven track records of durability, reliability, and minimal maintenance. Models 8127 and 8130 can be integrated into high volume production lines or as stand-alone testers for loading or quality control testing for efficiencies up to 99.999% (five 9 s). For more efficient filters, Models 3160 and 3140 determine efficiencies up to 99.999999% (eight 9 s). Model 3160 combines an Electrostatic Classifier with dual Condensation Particle Counters (CPCs) to measure most penetrating particle size (MPPS) from 15 to 800 nm using monodisperse particles. Model 3140 features a polydisperse oil aerosol generator and CPCs making it an ideal choice for quality control testing of high efficiency filters. TSI also offers a Component Filter Test System (CFTS) Model 3150- consisting of a software and hardware module- to provide an off the shelf solution for all your custom filter testing needs. Pre-configured to work with TSI s world class detectors and sizers, the CFTS provides a platform for numerous filter testing applications and can be configured to read signals from a wide variety of flowmeters, pressure transducers and sensors (temperature, pressure and relative humidity) to automate data collection. It can also provide signals to control blower flow, sampling valves, aerosol generators etc. Whether designing a new test duct or updating an existing system the CFTS provides an easy to use system with the flexibility to meet your filter testing needs. Features and Benefits + Solutions for all your filter testing needs + Simple, fast, and automated operation + Measurement of efficiencies up to 99.999999% (eight 9 s) + Determination of most penetrating particle size (MPPS) + Stable aerosol generators for highly repeatable and reproducible measurements + Designed for manufacturing environments and quality control testing Automated Tester Accessories TSI also offers a variety of optional accessories to diversify the capability and applicability of the automated filter testers. Individual models may also have additional accessories (refer to model specific information sheet). Custom Filter Holders TSI has an experienced design team and a fully-equipped machine shop to address special requirements from our customers. Over the years, TSI has designed and built more than 100 custom filter holders to accommodate testing filters with different shapes and sizes. We are ready to serve the specific needs you have. Please contact your TSI representative for details about the customized solutions we offer. External Adapter The Model 8107 External Adapter allows users to test tubular, rectangular or other irregular shaped filter cartridges that have their own housing. Additionally, all the filter testers are backed by TSI s commitment to provide superior customer support and service. MPPS results from Model 3160 MPPS results from Model 3160 232

Model 8127 and 8130 Model 3160 Model 3140 AUTOMATED TESTER SPECIFICATIONS Model 8127 a 8130 a 3160 3140 Measurement Application Loading and Quality Control Tests MPPS Quality Control Test Maximum Efficiency 99.999% 99.999999% 99.999999% Aerosol Type d DOP, PAO, DEHS, Paraffin, and other Oils DOP, PAO, DEHS, Paraffin, and other Oils or NaCl DOP, PAO, and other Oils or NaCl DOP, PAO, DEHS, Paraffin, and other Oils Aerosol Generation Atomizer Atomizer with Classifier Atomizer Count Median Diameter b 0.2 μm (Oil) 0.2 μm (Oil) or 0.075 μm (NaCl) Geometric Standard Deviation b <1.6 (Oil) <1.6 (Oil) or < 1.86 (NaCl) <1.3 <1.6 Flow Rate 15 to 100 L/min 5 to 100 L/min Resistance 0-150 mm H 2 O (0-1470 Pa) Particle Detection Light Scattering Photometer Condensation Particle Counter N/A 0.19 μm Typical Test Length 10 sec 30 sec to 20 min c < 1 min c Data Reporting Alpha-Numeric Display and RS-232 PC with Integrated Software Operation Stand Alone Tester/Automated Production Lines Stand Alone Tester Compliance US 42 CFR part 84, EN 143, JMOL, ISO 23328-1 EN 1822 parts 3 and 5 N/A a EN versions (for equivalent results to EN 143 standard) available (8127-1-EN, 8130-1-EN) b EN version CMD and GSD are different. See 8127/8130 spec sheet for more info c Efficiencies higher than 99.9999% require longer than typical testing times d Aerosol abbreviations: DOP (dioctyl phthalate), PAO (polyalpha olefin), DEHS (di-ethylhexyl sebacate) 3

BRINGING IT ALL TOGETHER CFTS: HOW IT WORKS COMPONENT FILTER TEST SYSTEM TSI offers a Component Filter Test System (CFTS Model 3150) for those applications that are not possible with TSI s automated testers. For the wide range of flow rates and particle sizes needed to meet the requirements of the many filter testing standards and research needs, an automated tester is not always practical. Building a filter test system from components is often the best way to satisfy your measurement needs. TSI has developed the CFTS as an easy to use system that integrate all the necessary parts of this type of system. The Component Filter Test System (CFTS) Model 3150 is an instrument platform that connects to the components for air filter testing applications. Flexibility Filters are used for a wide variety of application and are therefore tested to a variety of filter test standards. To satisfy these many requirements you need a filter testing system that is flexible enough to change to meet those requirements. The CFTS system is designed for flexibility. CFTS is structured as a core platform which controls the filter test. Its graphical user interface is used to define the test layout and procedures as well as being your interface for running the test. The CFTS has drivers to communicate with the particle instruments and is the interface for reading sensors and controlling flow. During testing it collects, saves and exports the data needed for test reports. Complete Solution As an instrument manufacturer TSI builds many of the instruments that can be used in these types of systems. Some components of these systems are best obtained locally (such as sheet metal work and welding needed to build duct segments) or from suppliers that specialize in those products (such as blowers, blower controls, pressure transducers and other sensors). While many components can be controlled or read manually it is desirable to integrate as much of a system as possible to provide an easier to use automated platform for filter testing. The CFTS system provides the connections and software to make configuration of these systems easier. No longer is custom software is no longer required for every component change. 4

STANDARDS AND REGULATION Air and gas filter testing methods are largely determined by standards and regulations. Large number of standards exist, each one appropriate for the application that category of filters is designed to be used for. Test standards, to a large extend, define the users filter testing needs. The table below gives examples of standards and which combinations of components are needed to test to the standards. Filter Type Standard Number CFTS OPS APC Photometer CPC Electrostatic Classifier Neutralizer Generator Ventilation ASHRAE 52.2 x x x x KCl/Dust Ventilation EN779 x x x Oil/Dust Automotive Cabin Air DIN 71460-1 x x x Dust Automotive Cabin Air ISO TR 11155-1 x x x KCl/Dust Automotive Engine Intake ISO CD/DIS 17913 x x KCl Crankcase ventilation ISO/DIS 20654 x x KCl Compressed Air VDI 3926-2 x x Dust Vacuum Cleaner ASTM F1977-04 x x x KCl Vacuum cleaners EN 60312 / IEC 60312 x x Dust Cleanable filters ISO 11057 / VDI 3926-1 x x Dust Air Cleaner AHAM AC-1-1988 x x x Dust HEPA-ULPA Media EN 1822-3 x x* x x Oil HEPA-ULPA Panels EN1822-5 x x x x x Oil HEPA-ULPA Panels IEST RP-CC001/CC007 x x x x x x Oil HEPA-ULPA Cannisters Mil Std x x x x x Oil HEPA-ULPA Media IEST RP-CC001/CC007 x x x x Oil Medical Face Mask ASTM F2299-03 x x PSL Respirator 42 CFR part 84 x x x Oil & NaCl Respirator EN 143 and 149 x x Oil/NaCl/Dust Medical Ventilator ISO 23328-1 x x NaCl Military Respirator Mil Std x x x Oil * Size range or resolution or not fully satisfied with this detector 5

WHY CFTS? TSI s CFTS provides a solution for the entire air filter test market due to its ability to be configured without the need of software customization. Small filter media test stands or large, high flow rate filter test benches can all be operated with the CFTS. Whether you are building your own customized test rig, updating an existing test system or developing your system, with the help of a system integrator, TSI s CFTS provides the platform on which you can build your system. Designing a Component System All filter test systems require some source of particle generation. In fact, multiple generators are often needed, and because generated particles can be highly charged, some form of neutralization is needed. Pressure transducers are often used both to measure the pressure drop across the filter under test but also for measuring pressure drop across the flow measurement device. This can be an orifice, a laminar flow element, or a flow nozzle. To control the flow rate on high flow systems large blowers are frequently controlled using variable frequency drives. These can be controlled manually or with a control voltage. Finally, the particles used to test the filter must be detected. Detectors include: Photometers (total light scatter detectors) optical particle counters (which give particle size based on light scatter) and condensation particle counters (CPCs) that detect and count particles down to very small sizes (10 nm and smaller). With CPCs a size selection device such as an Electrostatic Classifier is often used. PARTICLE GENERATION + Salt + Oil + Dust + PSL + Bacteria + Etc. Aerosol Generator TSI Components TSI Instruments (e.g. Photometer, OPS, APC, CPC, Electrostatic Classifier) can be used for a wide range of applications in the whole filter test market. In addition, all our aerosol generators and many of our aerosol measurement accessories can be used for filter testing. With the addition of the CFTS we can now offer solutions to potential users instead of just instruments. CFTS Connections CFTS is able to measure flow using a variety of flow measurement techniques and to control blowers to the required flow. It has multiple ports used to read temperature, pressure and relative humidity and make flow corrections and log sensor data for test reports. Optional Sample Switch PARTICLE CONDITIONERS + Drier + Neutralizer + Electrostatic Classifier Particle Conditioners Diluter (Optional) Make Up Air Filter δp Particle Counter or Sizer Optional 2nd Counter or Sizer PARTICLE DETECTORS OR SIZERS P, T, R.H. Flowmeter (laminar, orifice, nozzle, etc.) Flow + 3330 OPS + 8587A Photometer + 7110 Particle Counter + 3772 CPC with or without Electrostatic Classifier Blower 6

COMPONENTS AVAILABLE FROM TSI TSI has a range of particle generators, conditioners, detectors and sizers. The following is a list of some models that are currently available and supported with the CFTS system. As needs for other products are identified and new products are developed TSI will add to this list. Particle Generators: 3076 Constant Output Generator 8108 Large Particle Aerosol Generator 9306 Six-jet atomizer 9307 Oil Droplet Generator (Laskin Nozzle) 8118A Salt Generator (used in 8130 AFT) 1081414R Oil Generator (used in 8127/8130 AFT) 8118A-EN Salt Generator (Used in 8130-EN AFT) 1081414R-EN Oil Generator (used in 8127/8130 -EN) Particle Conditioners: 3077(A) Aerosol Neutralizer (Radioactive) 3054(A) Aerosol Neutralizer (Radioactive) 3087 Advanced Aerosol Neutralizer (Non-Radioactive) 308003 Electrostatic Classifier (w/o neutralizer or DMA) 3081 Long DMA (use with Electrostatic Classifier) 3332 Diluter (-10 and -100 versions) 33302A Diluter (-10 and -100 versions) Particle Detectors and Sizers: 3330 Optical Particle Sizer 3772 Condensation Particle Counter 8587A Laser Photometer 7110-5 AeroTrak Remote Particle Counter Particle Generators Instrument Size Range Concentration Flow Rate Count/Size 3330 OPS 0.3-10 µm 0-3000 /cm 3 1 L/min Up to 16 size bins 3772 CPC 0.01-2 µm 0-10000 /cm 3 1 L/min Total Count 8587A >0.1 µm 7110 Particle Counter 3480 Electrospray Aerosol Generator Series 3080 Electrostatic Classifiers 0.1-10 µm 3076, 3079, 9302 & 9306 Atomizers 1 µg/m 3 - >200 mg/m 3 2.0 L/min 0-40,000/ft 3 (0-1.4/cm3) 3076, 3079, 9302 & 9306 Atomizers 3076, 3079, 9302 & 9306 Atomizers 3400A Fuidized Bed Aerosol Generator 0.001 μm 0.01 μm 0.1 μm 1 μm 10 μm Instruments 3772 Condensation Particle Counter 8587A Laser Photometer 7110 AeroTrak Airborne Particle Counter 3330 Optical Particle Sizer 0.01 μm 0.1 μm 1 μm 10 μm 1 CFM (28.3 L/ min) Not Applicable 6 Size Bins Model 3772 Model 8587A Model 8180A Model 7110-5 Model 3330 7

FILTER TESTING OVERVIEW CFTS Software System Configuration Using System Configuration you can select dual counters or a single counter with a valve to select upstream or downstream. Different detectors can be used and when a CPC is selected you can use an Electrostatic Classifier. Different Aerosol generator and neutralizers can also be selected along with diluters (when needed) for measuring upstream of the test filter One OPS With Up/Down Switch Specifications Model 3150 Communication Interfaces 2 USB ports Serial I/O 4 ports RS 232 Analog Input Up to 8 channels Analog Output 2 channels (0 to 10 V, 4 to 20 ma only with external adapter) Two OPS Instruments Digital Input TTL-Level, up to 8 channels Digital Outputs Up to 12 channels 12 or 24 VDC selectable Measured Parameters (if sensors are connected) Filter Penetration and Efficiency Filter Resistance (differential pressure across filter) Filter flow rate Temperature Pressure Relative Humidity Classified aerosol with CPCs and Non-Radioactive Neutralizer Software Supplied with Component Filter Test System Software Classified aerosol with CPCs and Radioactive Neutralizer UNDERSTANDING, ACCELERATED TSI Incorporated - Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 4 91 11 87 64 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8251 6588 Singapore Tel: +65 6595 6388 P/N 5001174 Rev D 2012 TSI Incorporated Printed in U.S.A.