Filterpack FR-BFP2-(H)0.4K to (H)15K

Similar documents
This section is specifically about safety matters

VECTOR INVERTER -INSTRUCTION MANUAL- ADDITIONAL OPEN COLLECTOR OUTPUT / PLG PULSE DIVISION OUTPUT FR-V5AY

MITSUBISHI LARGE CAPACITY INVERTER MELTRAC-REC(MT-REC) -INSTRUCTION MANUAL- 12 Pulse Bridge Converter

Heatsink Protrusion Attachment. <FR-E7CN01 to 06>

TRANSISTORIZED INVERTER INSTRUCTION MANUAL HIGH-DUTY BRAKE RESISTOR FR-ABR(H)

FR-A7NP E kit cover SC

This section is specifically about safety matters

FR-BU2-1.5K to 55K FR-BU2-H7.5K to H280K

FR-BU2-1.5K to 55K FR-BU2-H7.5K to H280K

FR-A7AZ INSTRUCTION MANUAL

FR-CV-7.5K to 30K(-AT) FR-CV-37K, 55K FR-CV-H7.5K to H30K(-AT) FR-CV-H37K, H55K FR-CVL-7.5K to 55K FR-CVL-H7.5K to H55K FR-CV TRANSISTORIZED INVERTER

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

EVS RP6020. Instruction Manual

RP Instruction Manual

User Manual. SV-DBH Series. LG Dynamic Braking Units. LG Industrial Systems

MULTIFUNCTION REGENERATION CONVERTER FR-XC

FR-CV POWER REGENERATION COMMON CONVERTER MODEL

Pressure Transmitter

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Direct Coupled Damper Actuator Model MY6050A1001

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Hitachi America, Ltd.

AZ Series Motor OPERATING MANUAL. Introduction. Safety precautions. CE Marking

CRANE FUNCTION MANUAL. FR-A (0.4K) to 04750(90K)-CRN FR-A (0.4K) to 06830(280K)-CRN FR-A (315K) to 12120(500K)-CRN

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

High Frequency SineWave Guardian TM

B297SB-01-1K40. AnyWireASLINK System Product Guide. ASLINKSENSOR [Photo Interrupter type] -B297SB011K40 1/7- [Function] [Notes on Safety]

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Direct Coupled Damper Actuator Model MY9050A1001

DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Butterfly Valves ASAHI AV VALVES

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use

INSTRUCTION MANUAL. Braking Resistor

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

DRB-1 Series Instruction Manual

POWER REGULATOR LD -40PSU

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Lumitester PD-20 Control Kit

FREQUENCY INVERTER INSTALLATION & USER GUIDE

Braking unit Option Instruction Manual PB7-4132K

TOD-BCU-PNUS2. User's Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System)

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

FX2N-2LC SPECIAL FUNCTION BLOCK

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Diaphragm Valve Type 72

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

User s Manual Power Supply IM E. 5th Edition

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

I. Safety precautions

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

TDBU Series Dynamic brake unit user manual

HEAVY DUTY POWER RELAYS FEATURES

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Lead-free glass Nickel plated brass Ceramic 100 ma 15 A. Tube: End-cap: Core: Solder: 200 A. Marking: 100 ma 8 A Over 8 A 20 A. Rated breaking current

Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu. Pb87.5-Sn10-Ag2.5* ma less than 1 A.

OPERATING INSTRUCTION

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

PL Submersible, Semi-Vortex, Water Feature Pump

TDK Lambda TEP INSTRUCTION MANUAL

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Spec.No. CBF2525-VBVB-01E-1. Orion Model CBF2525-VBVB-01. Date Aug APPD CKD DWN. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD.

Technical information for LFU20-Z07-3A-X2

HARDWARE MANUAL. 1. Introduction. 2. Outline of Product. 3. Name of Each Part [MAIN UNIT INSTRUCTION MANUAL] JY992D88901B

Diaphragm Valves Type 15

M Series External Battery Frame. User Guide

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

BRUSHLESS BLOWER 60DCF DCF DCF-478. Instruction Manual

HIB Enclosed Inverter User Guide

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Flat-Right Angle Transfer

1329I Integrated Drive/Motor CE Filter Option Kit

Butterfly Valve Type 58 (PDCPD)

Internet For latest information, PDF catalogs and operation manuals

BM kv Digital Insulation Tester USER MANUAL

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

EISHO TEK. Vacuum Circuit Breaker

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

ROGOWSKI LEAK METER MODEL RLM-1

Technical Documentation

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

TOWA SEIDEN INDUSTRIAL CO., LTD.

MYPMA01218RCF-CAB Non-isolated type

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

Motorized Two-Way Ball Valve with Screwed-End Connection

Galaxy VM. Battery Breaker Box Installation 09/

DRL-1 Series Instruction Manual

Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A. Tube: End-cap: Solder: Adhesive: Marking: 1 A 3 A

System Monitoring SCHOOLMETERBOX AU

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Appendix: Safety and application notes for 19

Transcription:

INVERTER INSTRUCTION MANUAL FR-BFP2-(H)0.4K to (H)15K 1. Product Checking... 1 2. Applicable Inverter... 1 3. Installation... 2 3.1 Inverter Installation (installation of the )...2 4. Wiring... 4 5. Main Circuit Terminal... 5 6. Leakage Current... 5 7. Rating Specifications... 5 8. Outline Dimension... 6 B

Thank you for choosing this Mitsubishi Inverter option unit. This Instruction Manual gives handling information and precautions for use of this equipment. Incorrect handling might cause an unexpected fault. Before using the equipment, please read this manual carefully to use the equipment to its optimum performance. Please forward this Instruction Manual to the end user. 3. Injury Prevention This section is specifically about safety matters Do not attempt to install, operate, maintain or inspect this product until you have read through this instruction manual and appended documents carefully and can use the equipment correctly. Do not use this product until you have a full knowledge of the equipment, safety information and instructions. In this instruction manual, the safety instruction levels are classified into "WARNING" and "". WARNING Assumes that incorrect handling may cause hazardous conditions, resulting in death or severe injury. Assumes that incorrect handling may cause hazardous conditions, resulting in medium or slight injury, or may cause physical damage only. Note that even the level may lead to a serious consequence according to conditions. Please follow the instructions of both levels because they are important to personal safety. SAFETY INSTRUCTION 1. Electric Shock Prevention WARNING While power is ON or when the inverter is running, do not open the terminal cover of the option unit. Do not run the inverter with wiring cover removed. Otherwise, you may get an electric shock. Before starting wiring or inspection, switch OFF power, wait for at least 10 minutes after the power supply has been switched OFF, and check that there are no residual voltage using a tester or the like. The capacitor is charged with high voltage for some time after power OFF and it is dangerous. Any person who is involved in the wiring or inspection of this equipment should be fully competent to do the work. Always install the inverter and the option unit before wiring. Otherwise, you may get an electric shock or be injured. Do not touch the option unit or handle the cables with wet hands. Otherwise you may get an electric shock. Do not subject the cables to scratches, excessive stress, heavy loads or pinching. Otherwise you may get an electric shock. 2. Fire Prevention Install this option unit on a nonflammable wall without holes. Mounting it to or near flammable material can cause a fire. Apply only the voltage specified in the instruction manual to each terminal. Otherwise, burst, damage, etc. may occur. Ensure that the cables are connected to the correct terminals. Otherwise, burst, damage, etc. may occur. Always make sure that polarity is correct to prevent damage, etc. Otherwise, burst, damage, etc. may occur. While power is ON or for some time after power-off, do not touch the option unit as they will be extremely hot. Doing so can cause burns. 4. Additional Instructions Also note the following points to prevent an accidental failure, injury, electric shock, etc. 1) Transportation and mounting Transport the product using the correct method that corresponds to the weight. Failure to observe this may lead to injuries. Do not install or operate the option unit if it is damaged or has parts missing. Do not stand or rest heavy objects on the product. Check that the mounting orientation is correct. Prevent other conductive bodies such as screws and metal fragments or other flammable substance such as oil from entering the inverter. As this option unit is a precision instrument, do not drop or subject it to impact. Use this option unit under the following environmental conditions: Otherwise, the option unit may be damaged. Environment Surrounding air -10 C to +50 C (non-freezing) temperature Ambient humidity 90%RH maximum (non-condensing) Storage temperature -20 C to +65 C *1 Atmosphere Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt) Altitude/ vibration *1 Temperature applicable for a short time, e.g. in transit. *2 When installing the of 11K or 15K on the rear side of the inverter, do not install on moving objects or places which vibrates (exceeding 1.96m/s 2 ). 2) Usage WARNING Do not modify the equipment. Do not perform parts removal which is not instructed in this manual. Doing so may lead to fault or damage of the product. 3) Disposal Treat as industrial waste. 4) General instruction Maximum 1,000m above sea level. 5.9m/s 2 or less at 10 to 55Hz (directions of X, Y, Z axes) *2 All of the diagrams and drawings in this Instruction Manual show the option unit without a terminal cover, or partially open. Never operate the products in this manner. Always replace the cover and follow this Instruction Manual when operating the products.

This option is a dedicated unit for FR-E700 series, FR-D700 series, and FR-F700PJ series, which contains a DC reactor, common mode choke and capacitive filter. 1. Product Checking Unpack the option unit and confirm that the product is as you ordered and intact. type FR-BFP2- H Symbol Applicable power voltage None 200V class H 400V class Parts name and plate K 0.4 to 15 Represents the applicable inverter capacity Rating plate Filter pack type Rating SERIAL number MODEL FR-BFP2-H0.4K BKO- RATED SERIAL MITSUBISHI ELECTRIC CORPORATION Installation hole Inverter rear panel installation screw hole Crimping terminals for the inverter connection Black cable: connect to terminal R, S and T of the inverter Red cable: connect to terminal P and P1 of the inverter Green and yellow striped cable: connect to the earth (ground) terminal Terminal block cover Power supply connection terminal block Earth (Ground) terminal Accessories Name Description Quantity Screw for leakage current countermeasure and spacer Rear panel installation L- bracket Screw for inverter rear panel installation When the earth leakage breaker or earth leakage relay operates unnecessarily due to leakage current, use this screw as a countermeasure. * The screw size differs according to capacities. ((H)7.5K or lower: M4 14, (H)11K, (H)15K: M5 20) 2. Applicable Inverter Use the along with the inverter in the following table. * Select the capacity to make the load current (inverter output) lower than the permissible inverter output current. Refer to page 1 for each 5 Included with the 5.5K or higher 1 2 Use these screws for installation of the onto the inverter rear panel. 4* 2 Applicable inverter Permissible inverter D700 F700PJ E700 output current (A) * FR-BFP2-0.4K FR-D720-0.4K FR-F720PJ-0.4K FR-E720-0.4K 2.5 FR-BFP2-0.75K FR-D720-0.75K FR-F720PJ-0.75K FR-E720-0.75K 4.2 FR-BFP2-1.5K FR-D720-1.5K FR-F720PJ-1.5K FR-E720-1.5K 7 FR-BFP2-2.2K FR-D720-2.2K FR-F720PJ-2.2K FR-E720-2.2K 10 FR-BFP2-3.7K FR-D720-3.7K FR-F720PJ-3.7K FR-E720-3.7K 16.5 FR-BFP2-5.5K FR-D720-5.5K FR-F720PJ-5.5K FR-E720-5.5K 23.8 FR-BFP2-7.5K FR-D720-7.5K FR-F720PJ-7.5K FR-E720-7.5K 31.8 FR-BFP2-11K FR-D720-11K FR-F720PJ-11K FR-E720-11K 45 FR-BFP2-15K FR-D720-15K FR-F720PJ-15K FR-E720-15K 58 FR-BFP2-H0.4K FR-D740-0.4K FR-F740PJ-0.4K FR-E740-0.4K 1.2 FR-BFP2-H0.75K FR-D740-0.75K FR-F740PJ-0.75K FR-E740-0.75K 2.2 FR-BFP2-H1.5K FR-D740-1.5K FR-F740PJ-1.5K FR-E740-1.5K 3.7 FR-BFP2-H2.2K FR-D740-2.2K FR-F740PJ-2.2K FR-E740-2.2K 5 FR-BFP2-H3.7K FR-D740-3.7K FR-F740PJ-3.7K FR-E740-3.7K 8.1 FR-BFP2-H5.5K FR-D740-5.5K FR-F740PJ-5.5K FR-E740-5.5K 12 FR-BFP2-H7.5K FR-D740-7.5K FR-F740PJ-7.5K FR-E740-7.5K 16.3 FR-BFP2-H11K FR-D740-11K FR-F740PJ-11K FR-E740-11K 23 FR-BFP2-H15K FR-D740-15K FR-F740PJ-15K FR-E740-15K 29.5 1

3. Installation 3.1 Inverter Installation (installation of the ) 3.1.1 Installation of the inverter and (for rear panel installation) 0.4K to 3.7K Remove the front cover and wiring cover to attach the inverter. Screw for inverter rear panel installation Screw for inverter rear panel installation Front cover Front cover Screw for inverter rear panel installation Screw for inverter rear panel installation Wiring cover Wiring cover 5.5K to 15K Remove the L-bracket installation screws from the (two for the 7.5K or lower, three for the 11K or higher), and attach the included L-bracket to the with these screws. Remove the front cover to attach the inverter. L-bracket installation screw Rear panel installation L-bracket Screw for inverter rear panel installation Screw for inverter rear panel installation When installing the to the inverter, use the included installation screws for the inverter rear panel. Using a longer screw may damage the. Rear panel installation is not available for FR-E720-5.5K and 7.5K, FR-E740-0.4K to 3.7K. 2

3.1.2 Installation of the The following installations are recommended for the and inverter. When encasing multiple inverters, install them in parallel as a cooling measure. Install the inverter () vertically. Side-by-side installation is not available for s. For wiring of the and inverter, refer to page 4 Rear panel installation Side panel installation 1cm When installing the of 11K or 15K on the rear panel of the inverter, do not install on moving objects or places which vibrate (exceeding 1.96m/s 2 ). To release heat of the inverter and, leave clearance of 1 cm or more when installing the inverter and. Underneath installation 10cm Install the with the wiring portion facing right. Underneath installation is not available for 11K and 15K. To release heat, leave clearance of 10cm or more between the inverter and. Installation of the inverter and Install the cable carefully without subjecting it to excessive stress when wiring. Also be careful not to damage the cable with sharp items such as an edge of a metal sheet. To prevent malfunctions and damages, never perform installations in the following manner. Only install according to the recommended mounting methods. Invert installation of the Sideway installation of the 3

4. Wiring Wire the and the inverter according to the following connection diagram. Connect the to an input side of the inverter. After wiring, attach the terminal cover of the to the terminal block. Connection diagram Three-phase AC power supply *2 *2 MCCB MC *1 POINT Jumper: Remove this jumper to connect the. FR-BFP2 R0 S0 T0 R S T P P1 GND Inverter R/L 1 S/L 2 T/L 3 P/+ P1 N/- U V W Motor IM Earth (Ground) *1 Connect the GND cable of the to the earth (ground) terminal of the inverter. earth (ground). The inverter is earthed (grounded) through the. *2 For cable size for MCCB, MC and, refer to the inverter Instruction Manuals. MCCB and MC should be selected with reactor connection. Use the earth (ground) terminal of the to Wiring of the inverter and Perform wiring of the inverter and in the following procedure. (1) Connect the commercial power supply to the terminal R0, S0 and T0 of the. (2) Connect the earth (ground) cable (green and yellow striped cable) of the to the inverter earth (ground) terminal. (3) Connect the power supply cable (black cable) of the to the terminal R, S and T. REMARKS Phase sequence need not be matched. (4) Remove the jumper across terminals P and P1 of the inverter, and connect the P and P1 cables (red cable) of the. (5) Connect the motor cable to the inverter output terminals (U, V, W). (Match the phase sequence.) Remove the jumper. N/- P/ + P1 R/L1 S/L2 T/L3 U V W P P1 R S U V W T GND R0 S0 T0 R S T IM Power supply motor Make sure that the power cables are connected to the R0, S0 and T0 of the. (Phase sequence need not be matched.) Never connect the power cable to the U, V, W of the inverter. Doing so will damage the inverter. When connecting the, make sure that the jumper across the terminals P and P1 of the inverter is removed. 4

5. Main Circuit Terminal Terminal symbol Terminal name Description R0, S0, T0* Commercial power supply input Connect to the commercial power supply. Earth (Ground) The must be earthed (grounded). Crimping terminal symbol Terminal name Cable color Description R, S, T Inverter power supply Black Connect to the R, S, T of the inverter. P, P1 DC reactor terminal Red Remove the jumper across terminals P and P1, and connect to the terminals P and P1 of the inverter. GND * The terminal screw size is the same as that of the inverter terminal R, S and T. 6. Leakage Current When using the, the leakage current is about 4mA (8mA for the 400V class)(for one phase of the three-phase three wire connection current). When using the, leakage current will be reduced by removing the earth (ground) cable of the capacitive filter, and fixing it with the included screw for leakage current countermeasure (plastic) and spacer (plastic). However, the noise reduction effect of the capacitive filter will be lost. (Pull out the earth (ground) cable slightly to wire the capacitive filter.) Installation Inverter earth (ground) connection Green and yellow stripes Connect to the earth (ground) terminal of the inverter. (Refer to page 4) Screw for leakage current countermeasure (plastic) (tightening torque: 0.35 0.05Nm) Spacer (plastic) Earth (ground) cable for capacitive filter When the earth (ground) cable for the capacitive filter is removed, the cable is charged while power is ON or shortly after power OFF. Do not touch the earth (ground) cable as you may get an electric shock. 7. Rating Specifications 200V class Type FR-BFP2- K 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 Approximate mass (kg) 1.3 1.4 2.0 2.2 2.8 3.8 4.5 6.7 7.0 Power factor improving reactor Install the DC reactor in the DC side. 93% to 95% (94.4% *1) of power supply power factor under 100% load Noise filter Common mode choke Install a ferrite core on the input side Capacitive filter About 4mA of capacitor leakage current * Protective structure (JEM1030) Open type (IP00) 400V class Type FR-BFP2-H K 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 Approximate mass (kg) 1.6 1.7 1.9 2.3 2.6 4.5 5.0 7.0 8.2 Power factor improving reactor Install the DC reactor in the DC side. 93% to 95% (94.4% *1) of power supply power factor under 100% load Noise filter Common mode choke Install a ferrite core on the input side Capacitive filter About 8mA of capacitor leakage current *2 Protective structure (JEM1030) Open type (IP00) *1 The values in parentheses are calculated by applying 1 power factor to the reference waveform in accordance with the Architectural Standard Specifications (Electrical Installation) (2010 revisions) in Japan. *2 * The indicated leakage current is equivalent to one-phase of the three-phase three wire connection cable. 5

8. Outline Dimension FR-BFP2-0.4K, 0.75K 2-φ4.5 hole 2-φ4.5 hole 1.6 15 Rating plate 4.5 30 60 5 208 5 15 218 208 5 5 220 19 4.5 30 68 19 1.6 240 (GND) (R) (S) (T) (P1) (P) Crimp ring terminalφ4.3 Unit mm 6

FR-BFP2-1.5K, 2.2K, 3.7K FR-BFP2-H0.4K, H0.75K, H1.5K, H2.2K, H3.7K 2-φ 4.5 hole 2-φ 4.5 hole 178 5 5 188 178 (*1) Rating plate 1.6 12.5 D1 D 4.5 5 12.5 5 W2 L1 W W1 L 4.5 W2 1.6 200V power supply Crimp ring terminalφ4.3 (GND) (R) (S) (T) (P1)(P) Capacity W W1 W2 D D1 L L1 1.5K, 2.2K 108 55 26.5 80 55 200 220 3.7K 170 120 25 65 40 220 240 400V power supply * The 400V class H0.4K and H0.75K have no slit. (Unit: mm) Capacity W W1 W2 D D1 L L1 H0.4K, H0.75K* 108 55 26.5 55 30 200 220 H1.5K, H2.2K, H3.7K 108 55 26.5 80 55 200 220 (Unit: mm) 7

FR-BFP2-5.5K, 7.5K, 11K, 15K FR-BFP2-H5.5K, H7.5K, H11K, H15K 2.3 12.5 Rating plate C1 D1 D 2- φc hole H2 H1 H2 12.5 L-bracket for rear panel installation of the inverter (enclosed) H H2 H1 H2 25 (25) 310 2- φc hole L 145 195 220 L1 C1 25 2.3 200V power supply (R) (S) (T) (P1)(P) (GND) Crimp ring terminalφc2 Capacity H H1 H2 D D1 C C1 C2 L L1 5.5K, 7.5K 210 198 6 75 50 4.5 4.5 5.3 270 400 11K 320 305 7.5 85 60 6 6 5.3 280 280 15K 320 305 7.5 85 60 6 6 6.4 260 260 400V power supply (Unit: mm) Capacity H H1 H2 D D1 C C1 C2 L L1 H5.5K, H7.5K 210 198 6 75 50 4.5 4.5 4.3 270 400 H11K 320 305 7.5 85 60 6 6 4.3 280 280 H15K 320 305 7.5 85 60 6 6 6.4 260 260 (Unit: mm) 8 IB(NA)-0600378ENG-B

REVISIONS *The manual number is given on the bottom left of the back cover. Print Date * Manual Number Revision Jan. 2009 IB(NA)-0600378ENG-A First edition Jun. 2011 IB(NA)-0600378ENG-B Modification Earth (ground) cable (GND) length for FR-BFP2-(H)5.5K and 7.5K. 9

HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN IB(NA)-0600378ENG-B(1106)MEE Printed in Japan Specifications subject to change without notice.