XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

Similar documents
XP-115 Multi-Port Power Pack Operation and Maintenance Manual

KLW4000D Multi-Port Power Pack


IBT Series Square Drive Torque Wrenches

HexPro Series Low Profile Wrenches

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Operating instructions Form no safety definitions

Low Profile Wrenches Operation and Maintenance Manual


RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

OPERATION AND MAINTENANCE MANUAL

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

Air / Hydraulic Pump

Air / Hydraulic Pump Instructions. CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine.

Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench -

OPERATOR S MANUAL Model 60010

Operating, Servicing, and Safety Manual Model # Hydraulic Bender

Collision Repair Set. Form No No. 1517A 4-Ton Set. No. 1519A 10-Ton Set. Parts List & Operating Instructions for: 1519A. Part No. Item No.

Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches

Hydraulic Hub Grappler Kit

Rear Suspension Bushing Remover/Installer

SERIES OPERATION AND MAINTENANCE MANUAL

Porta-Punch Manual

Explanation of Safety Signal Words

OPERATIONSMANUAL SUPERIOR BOLTING SOLUTIONS

Hand Pump Instruction Manual

ZipPULLER Subsea Flange Puller

PE39 Series Compact Torque Wrench Pump

MANUAL PALLET VALVE # Manifold Mount Outlet Port # /16-20 UNF SAE-4 Outlet Port # /4 NPT Outlet Port Max. Capacity: 5,000 PSI

Operating, Servicing, and Safety Manual Model # Hydraulic Bender

Operating Instructions for: PE10 Series. Electric-Powered 10 Series Hydraulic Pump SPX

User Manual for: PE8 Series PE17 Series. Electric-Powered 8 & 17 Series Two-Stage Hydraulic Pump SPX

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

FTMP-8 AND FTMP-12 Midget Puller Units

IN-LINE HYDRAULIC FLOW TESTER

Instruction Manual. Maximum Operating Pressure 700 bar

Instruction Manual. Maximum Operating Pressure 510 bar

Instruction Sheet 1 1/8 HP TITAN PUMPS SAFETY FIRST

15,000kg HYDRAULIC BOTTLE JACK

Instruction Manual. Double Acting Hydraulic, Hollow Piston Cylinders RHD Series. Maximum Operating Pressure 700 bar

Gauge Adapter Instruction Manual

Super Tube Tugger. Operating and Maintenance Instructions

Stub Tugger. Operating and Maintenance Instructions

Manifold w/ Needle Valve Instruction Manual

User Manual for: PE8 Series PE17 Series. Electric-Powered 8 & 17 Series Two-Stage Hydraulic Pump SPX

OWNER S MANUAL PRODUCT CODE: 2006T

Hand Pump Instruction Manual

Hand Pump Instruction Manual

OPERATING INSTRUCTIONS. HTL-DSX Dedicated Square Drive Wrench

Flexfence Tension Unit. with Hand Pump. Product Manual. Release 02/16.

Model Repair Parts Sheet SPECIFICATIONS. Stake threads lightly after assembly. Note: Pump base is not available as a service item.

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

MODEL 890 / 892 POWER POST 10 TON CAPACITY

User Manual for: PE30 Series. Electric-Powered 30 Series Hydraulic Pump SPX

Clevis Plunger & Base Instruction Manual

Hydraulic Gear Puller Instruction Manual

PE 20 SERIES ELECTRIC POWER PUMPS

SW9TM, SW14.5TI, SW15TE

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

Gas Engine Pumps Instruction Manual

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

HYDRAULIC PUMP BATTERY POWERED. Operating Instructions for: SPX Hydraulic Technologies th Street Rockford, IL USA powerteam.

Air Hydraulic Pumps Instruction Manual

Instruction Manual. Single Acting, Pancake, Locking Collar Hydraulic Cylinders RPLC Series. Maximum Operating Pressure 700 bar

50:1 Grease Pump Kits

Hydraulic Knockout Sets

Table of Contents. XXI/Avanti/Stealth SERIES Operational Manual. 2-3 Electrical Connections 2-4 Air Connections

OPERATION MANUAL FOR SQUARE DRIVE & LOW PROFILE HYDRAULIC TORQUE WRENCHES NOTICE WARNING

Electric-Powered PE8 Series Hydraulic Pump

Air Hydraulic Pumps Instruction Manual

Rams. Operating Instructions & Parts Manual. Model Number B65141 B65553 B65555 B65441 B65446 B65449 B65746

INSTRUCTIONS Refillable, reusable. Extra versatile. Pressurized by free air

INSTRUCTIONS Refillable, reusable. Extra versatile. Pressurized by free air

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT

INSTRUCTIONS DURA SHOT S SPRAYERS DIRECTIONS FOR OPERATING DURA SHOT S. 24 oz. DURA SURE SHOT S SPRAYER.

High Tonnage Single Acting Cylinders Instruction Manual

Viscount I Hydraulic Motor and Displacement Pump

Service Jack. Form No Parts List & Operating Instructions 1510B. Max. Capacity: 5 and 10 Tons. 1 of 3. Sheet No. Issue Date: Rev.

SLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE

Table of Contents. XXI/Avanti/Stealth SERIES Operational Manual. 2-3 Electrical Connections 2-4 Air Connections

1.5 TON ALUMINUM RACING JACK

SPECIFICATIONS CONTENTS: Specifications Warning Information. Operating Instructions Preventative Maintenance Troubleshooting

Hydraulic PTO Flow Device

Air-Assist Service Jack Max. Capacity: 10 Tons

SW9TM, SW14.5TI, SW15TE

ALUMINUM RESERVIOR 10,000 PSI, AIR-HYDRAULIC PUMP

Maximum Operating Pressure 10,000 PSI

FT-20 Portable PowerPak

Instruction Manual. Square Drive Hydraulic Torque Wrenches Model TW Series. Maximum Operating Pressure 700 bar

Single Acting Aluminum Cylinders Instruction Manual

Instruction Manual. Single Acting, High Tonnage, Low Height Cylinders RSH Series. Maximum Operating Pressure 700 bar

HT125KM, FA3TM, FA6TE

Instruction Manual. Single Acting, Aluminium, Locking Collar Hydraulic Cylinders ARSLC Series. Maximum Operating Pressure 700 bar

PNEUMATICS CONTENTS HST-TAMPER

Coolant Purification Systems Ultra 360 INSTRUCTION MANUAL

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

Electric Pump Instruction Manual

Operating Instructions - Electric Pow'r-Riser Models

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

OPERATING INSTRUCTIONS FOR HTWP2141AR AND HTWP2142AR SERIES ELECTRIC MOTOR DRIVEN AUTORETRACT TORQUE PUMPS

Transcription:

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual http://www.torsionx.com

Safety Guide To use the XP-AIR Multi-Port Power Pack safely you must follow correct operation guidelines and inspect the equipment regularly. Read and follow all instructions and put on proper personal protective equipment (PPE) prior to use. UPON RECEIPT OF THIS TOOL, INSPECT THE PACKAGE FOR DAMAGE. Carefully inspect all components for damage incurred during shipping. If any shipping damage is found, notify the carrier at once. Shipping damage is NOT covered by warranty. The carrier is responsible for all repair or replacement costs resulting from damage in shipment. Neither TorsionX, nor its distributors are responsible for damage caused by unsafe and/or faulty operations. If a problem arises during use, shut off the power immediately and consult your TorsionX distributor. ALL OF OUR PRODUCTS MAY HAVE UPGRADES AND MODIFICATIONS WITHOUT NOTICE. Table of Contents Warnings...3 XP-AIR Multi-Port Power Pack...4 Hydraulic Couplers...4 Set Up...5 Operation...7 Features:...7 Warranties...8 Trouble Shooting Guide...9 Appendix...10 TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 2

Warnings Hydraulic Hose: Inspect hose for wear and damage prior to every use. Only use twin line high pressure hydraulic hoses rated for 10,000 PSI with at least a 3:1 safety factor. The maximum operating pressure is 10,000 PSI - Do not exceed 10,000 PSI. Do not let the hose kink, twist, curl or bend so tightly that oil flow within the hose is blocked or reduced. The minimum bending radius: R>5 inch. Too small of a bending radius will kink and destroy the high pressure hydraulic hose. Before operating the hydraulic power pack, tighten all hydraulic hose connections with the proper tools. Do not overtighten. Connections should be tightened securely and leak-free. Over tightening can cause premature coupler thread failure. Shut off the air motor before breaking any hydraulic connections in the system. Should a hydraulic hose ever rupture, burst, or need to be disconnected, immediately shut off the hydraulic power pack. Never attempt to grasp a leaking pressurized hose with your hands. The force of the escaping hydraulic fluid could cause serious injury. Do not subject the hose to potential hazards such as: Fire Sharp surfaces Extreme heat or cold Heavy impact Hose material and coupler seals must be compatible with the hydraulic fluid. Keep hoses away from contact with corrosive materials such as creosoteimpregnated objects and some paints and solvents. Never paint a hydraulic hose. Never paint hydraulic couplers. Hose deterioration due to corrosive materials can result in premature failure and serious personal injury. TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 3

XP-AIR Multi-Port Power Pack Do not exceed the maximum hydraulic pressure rating of 10,000 PSI. Do not tamper with the internal high pressure relief valve. Creating pressure beyond rated capacities can result in serious personal injury. Before replenishing the hydraulic oil, retract the system to prevent overfilling the pump reservoir. Overfilling can cause personal injury due to excess reservoir pressure created when the wrenches are retracted. Power Supply: Disconnect the hydraulic power pack from the power supply when performing maintenance or repairs. If the power supply is damaged or the external air feed is damaged in any way, replace immediately. Air supply pressure (100 PSI) and flow rate (50 CFM). Hydraulic Couplers Never overtighten the hydraulic coupler. Over tightening can cause premature thread failure. Check for gaps in the hydraulic coupler. Gaps can cause a disruption in the flow of hydraulic fluid. Gaps will cause the hydraulic torque wrench to not operate. Immediately replace any worn or damaged hydraulic couplers. Do not use the hose to move the attached equipment. Figure 1 IMPORTANT WHEN ONLY USING ONE HYDRAULIC TORQUE WRENCH, COVER THE EMPTY HYDRAULIC COUPLINGS WITH DUST CAPS. Operation Warnings: Do not permit anyone to stand in front of open hydraulic couplers during operation. Never exceed the maximum operating pressure of 10,000 PSI. Before performing any maintenance, shut off power. TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 4

Do not operate without oil. Keep the power pack clean. Do not operate in wet conditions. Set Up Filling the Reservoir: Attention: The power pack has been shipped without oil in the reservoir. Only use a high-grade (Grade 46 or better), quality non-foaming hydraulic oil. 1. Clean the area around the filler cap. a. Any dirt or grime in the hydraulic oil can damage the internal workings of the power pack. 2. Remove the filler cap, and insert a clean funnel. 3. Fill with hydraulic oil to 1 from the top of the filler hole. 4. Replace filler cap. 5. Cycle the power pack (with hydraulic torque wrench attached) several times. 6. Retract the hydraulic torque wrench and check the oil level in the power pack reservoir again. a. This will also help eliminate air from the system. Hydraulic Connections: 1. Inspect all hydraulic twin line hoses, threads and fittings for signs of wear or damage and replace as needed. 2. Clean all hose ends and hydraulic couplers. 3. Connect the twin line hydraulic hose to the hydraulic torque wrench and the power pack, making sure all hydraulic couplers are snug. 4. Jog the power pack several times. a. The power pack is now ready to be put into regular operation. TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 5

Adjusting the Hydraulic Pressure: NOTE: For easy adjustment of the pressure regulating valve always adjust the pressure by increasing to the desired pressure setting. 1. Loosen the locknut on the pressure regulating valve, and back the adjusting knob out a few turns. a. Do so by turning the adjusting knob in a counterclockwise direction. (Figure 2) Figure 2 b. This will decrease the pressure setting to a pressure lower than the desired pressure. ATTENTION: THE POWER PACK MUST BE COMPLETELY CONNECTED AND THE HYDRAULIC TORQUE WRENCH MUST NOT BE ON THE APPLICATION WHEN ADJUSTING THE PRESSURE. 2. Connect the air supply 3. Press the button on the top of the remote pendant to turn the power pack on. a. The power pack will deliver hydraulic oil to the low pressure port (Port B). 4. Press the button on top of the remote pendant Advance. a. The power pack will deliver hydraulic oil to the high pressure port (Port A). 5. While holding the button in the Advance position, slowly turn the adjusting knob in a clockwise direction. a. This will gradually increase the pressure setting. 6. When the desired pressure is reached, lock the adjusting knob in position by tightening the locknut. IMPORTANT: NEVER EXCEED 10,000 PSI TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 6

Operation 1. Press the top button on the pendant to advance the hydraulic torque wrench. 2. When you hear an audible Click from the hydraulic torque wrench, release the button. a. The hydraulic torque wrench will automatically retract. 3. When the hydraulic torque wrench is fully retracted, repeat the process until the desired pressure/torque rating is reached. To disconnect tools and hoses from system, you must release system pressure. a. To release pressure from system, press the button on top of the solenoid. (Figure 3) Figure 3 Attention: When using a hydraulic power pack for the first time, activate the hydraulic torque wrench prior to putting tool on an application; this will help remove any air from the system. Features: XP-AIR Multi-Port Power Pack is a three-stage power pack. The pressure relief valve is assembled in the high pressure port. Flow rates for the power pack by stage are: 50in /min in high pressure stage 110in /min in mid pressure stage 500in /min in low pressure stage Maximum operating pressure: 10,000 PSI The XP-AIR Multi-Port Power Pack can simultaneously run two torque wrenches at the same time. Acceptable working temperature: -20 F to 120 F Overall dimensions: 11.8 x 14.8 x 17.9 Weight (no oil): 60lbs Hydraulic oil: ISO VG 46# TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 7

Warranties 1. TorsionX guarantees the XP-AIR Multi-Port Power Pack quality for 12 months from the date of purchase. 2. If any quality issue due to the defects of the materials or workmanship is found within the guarantee period, TorsionX will repair or replace the defective products at TorsionX s discretion. 3. If the equipment is found to be damaged due to negligence, operating the power pack incorrectly, tampering with, or attempting to repair the power pack in part or whole, the warranty is invalidated. TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 8

Trouble Shooting Guide Malfunction Reason for malfunction Solution The power pack does not start. The system has no hydraulic pressure. The system still has no hydraulic pressure after checking the above. Hydraulic couplers are leaking. The desired hydraulic pressure can not be reached. There is a loud noise when the power pack is operated. Un-suitable power source. The power is not connected. The hydraulic couplers are not connected properly. No oil in the tank. Not enough oil in tank. Faulty pressure gauge. The hydraulic couplers may have a vacuum lock. The o-ring, is worn or missing in the female hydraulic couplers. The pressure setting for high-pressure relief valve is adjusted too low. Oil is mixed with water. Pressure relief valve broken. Air may be in system. High-pressure relief valve may be loose. The o-ring for high-pressure relief valve may be worn or missing. The bearing(s) may be worn or broken. Air may be in system. Confirm the power supply meets the pump s specifications. Check the power connection. Tighten or re-install. Fill oil. Fill oil. Replace gauge. Check hydraulic couplers to hydraulic torque wrench. Inspect couplers to ensure they are completely coupled. Occasionally couplers have to be replaced because the check ball does not stay open due to wear. Replace the hydraulic couplers. Replace high pressure relief valve. Replace the oil. Replace valve. Repeat operating the system with no load several times to eliminate air. Tighten valve. Replace o-rings. Replace bearing(s). Repeat operating the system with no load several times to eliminate air. High-pressure flow is reduced. Piston or spring may be broken. Hydraulic couplers may be loose. Oil level may be low. Oil may be too cold. Dirt in pump or filter is clogged. Replace piston assembly. Tighten hydraulic couplers. Fill with oil. Change hydraulic oil to a lighter grade. Replace filter and clean tank. TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 9

Appendix TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 10

TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 11

TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 12

TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 13

TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 14

TorsionX XP-AIR Multi-Port Power Pack (Updated 9/5/17) 15