How to Size VSD Air Compressors

Similar documents
Impact Evaluation of 2004 Compressed Air Prescriptive Rebates

Installation of High Speed Blowers

AIR COMPRESSOR IMPROVEMENTS

DIGITAL VALVE POSITIONER ENHANCES THE PERFORMANCE OF PRESSURE/FLOW CONTROL

Compressed Air Efficiency: A Case Study Combining Variable Speed Control with Electronic Inlet Valve Modulation

Jon Konings Former CEM Coordinator

Automation & Power World 2011 April 18-21, 2011 in Orlando, Florida

Evaluating Losses in Electrical Equipment Focus on Transmission Utilities. CNY Engineering Expo 2016 Syracuse, New York Arthur C. Depoian P.E.

Cooling System Simulation for Indian Utility Vehicle using COOL3D

Sacramento Municipal Utility District s EV Innovators Pilot

Sullair: An Industry Leader

SULLAIR Single-stage Rotary Screw Air Compressors

Contact-Cooled Rotary Screw Air Compressors. Nirvana kw ( hp)

K2 K2V Series. Premium Efficient Two-Stage Compressors. rogers-kseries.com RMC-K2/K2V-BROCHURE_REV.003 Record of Change A/B

TURBO-AIR 2000 Centrifugal Compressor

PET Compressed Air Solutions ,800 m 3 /hr

Turbocharger Compressor Calculations

Pilot document v1 Jan Fleet Manager User Guide

Energy Saving: Pneumatic Systems

CAGI Data Sheets. Blower Performance Comparison. Stephen Horne, Blowers Product Manager Kaeser Compressors, Inc.

WindLab TM Wind Turbine Power System Sample Laboratory Procedure Manual

Using Kinetic Energy for Plunger Lift Safety and Maintenance

Wheel Rail Interaction 2018 Sponsor Opportunities

USE OF THE PUMP SLIPPAGE EQUATION TO DESIGN PUMP CLEARANCES

Expo Information. NADA Show 2018 Las Vegas Convention Center 3150 Paradise Rd Las Vegas, NV 89109

OKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2017 RELIABILITY SCORECARD

How Much Can a Campus Save on Utility Bills By Turning a 5-Workday Week Into a 4-Workday Week?

SGCC Peer Connect: Consumer Resistance to Smart Grid Roll-out. August 29, 2012

TURBO-AIR 3000 Centrifugal Compressor

15-37 kw Rotary Screw Compressors

FE151 Aluminum Association Inc. Impact of Vehicle Weight Reduction on a Class 8 Truck for Fuel Economy Benefits

Overview of Blower Technologies and Comparison of High-Speed Turbo Blowers

SULLAIR Single-stage Rotary Screw Air Compressors

2018 WATT-HOUR METERING WORKSHOP

Product Loss During Retail Motor Fuel Dispenser Inspection

Using Asta Powerproject in a P6 World. Don McNatty, PSP July 22, 2015

Charging Delivery Body. 29 th January 2018

Atlas Copco Oil-free centrifugal compressors

OKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2018 RELIABILITY SCORECARD

Sullair: An Industry Leader

CHARLES RIVER POLLUTION CONTROL DISTRICT. Requirements for Septage Receiving

OIL-INJECTED MEDICAL AIR COMPRESSORS GA 5-11 MED / GA MED / GA 7-37 VSD+ MED

D C. Introduction Hoist Repowering Project for 4100A Shovels. P&H 4100A Hoist Repowering Project. Solutions Explored

Variable Speed Drive on a Die Casting Machine

Segen offer the SE2200, SE3000, SE3500, SE3680, SE4000, SE5000 and SE6000 single-phase inverters at great value prices.

Attachment F: Transport assessment report on implications if Capell Avenue never formed

Galapagos San Cristobal Wind Project. VOLT/VAR Optimization Report. Prepared by the General Secretariat

Atlas Copco Oil-injected Rotary Screw Compressors. G kw / hp

EMI / RFI Shielding Products. Shielding Honeycomb Ventilation Panels and Dust Filtration Characteristics

CCQTA TVP Project Update

MSG TURBO-AIR 2000 Centrifugal Compressor

DIESEL ENGINES MAINTENANCE PONSIBILIT Training Duration 05 days

VSO Thermally Compensated Proportional Valve

Transmission Error in Screw Compressor Rotors

CAGI Data Sheets. Blower Performance Comparison. Stephen Horne, Blowers Product Manager Kaeser Compressors, Inc.

Nirvana hp Variable Speed Drive Rotary Screw Compressors. The Next Generation of Compressed Air

Program. International GE LM6000, LM2500 & LM1600 User Conference. 6-9 November 2018, Crowne Plaza Hotel, The Hague The Netherlands

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties

Theoretical and Experimental Study on Energy Efficiency of Twin Screw Blowers Compared to Rotary Lobe Blowers

Small Cell Concealment

Steam Turbine Seal Rub

Ohio Alternative Fuel Vehicle Conversion Grant Program. Information Session January 25, 2018 Updated February 27, 2018

Atlas Copco Air Compressors. ZB VSD range Variable speed direct drive centrifugal air compressors for low pressure applications EFFICIENCY MATTERS

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

Critical Power: What s New in Electrical Engineering: Smart Grid and Transformers. Sponsored by:

NewsTrain Host Guide 2018

Ene-5 Peak Energy Demand Reduction

Bisnet Solutions for Tomorrow, Today! The Die Casting Process Planner. Users Manual. August 5, A Product By: Bisnet - 1 -

Theme Taking Energy Storage, Renewable Energy & Smart Grid forward in Africa.

RECIPROCATING ROTARY PUMPS & COMPRESSORS

Introduction: Supplied to 360 Test Labs... Battery packs as follows:

Nirvana Variable Speed Drive Rotary Screw Compressors kw

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

SULLAIR Two-stage Rotary Screw Air Compressors

MACP TB. 23 db Coupler MHz Rev. V1. Features. Functional Schematic. Description. Pin Configuration 4. Ordering Information 1,2

Gasoline and Diesel Blending Course

Crude Evaluation Best Practices

DELEGATE INFORMATION. 30 October 1 November 2018 ETIHAD STADIUM I MELBOURNE. Share, show. and shine. Proudly presented by

Refrigerant air dryers FX 1-22

REFRIGERANT AIR DRYERS FX 1-22

Effectiveness of ECP Brakes in Reducing the Risks Associated with HHFT Trains

Mini-Lab Gas Turbine Power System TM Sample Lab Experiment Manual

Counselor-In-Training Program Description and Application

Expo Information. NADA Show 2019

Variable Frequency Drives

CAGI Data Sheets. Blower Performance Comparison. Stephen Horne, Blowers Product Manager Kaeser Compressors, Inc.

Variable Speed-Drive Troubleshooting

Commercial & Industrial Retrofit 2017 Compressed Air Incentive

Reactive Power Compensation for Solar Power Plants. Andy Leon IEEE PES Chicago Chapter December 12 th, 2018

Large Electric Motor Reliability: What Did the Studies Really Say? Howard W Penrose, Ph.D., CMRP President, MotorDoc LLC

North Carolina Tire Dealers Association c01i EXPO/TRADE SHOW MARCH 2 nd 3 rd 2018 Raleigh City Center Marriott & Convention Center

Simulating Trucks in CORSIM

Power Team Mission Day Instructions

scfm (6.5 psi) Max HP

Choose quality. FIMA 1

C-BOA Tool. Comparison of Peak Demand Savings Estimation Methods. February 7, of 14

Faraday's Law of Induction

Stationary Battery Basics

Pepco & Delmarva Power. Commercial & Industrial Energy Savings Program Grocery and Convenience Stores October 11, 2012

Taking on the Leadership Challenge in Class 8 Trucking

Transcription:

How to Size VSD Air Compressors Sponsored by Tim Dugan, P.E., Compression Engineering Corporation Keynote Speaker For your free subscription, please visit www.airbestpractices.com/magazine/subscription.

How to Size VSD Air Compressors Tim Dugan, P.E., Compression Engineering Corporation Keynote Speaker The recording and slides of this webinar will be made available to attendees via email later today. Sponsored by PDH Certificates will be e-mailed to Attendees within two days. For your free subscription, please visit www.airbestpractices.com/magazine/subscription.

Handouts Engineering Services 2017 Energy analysis services: For industrial compressed air, process vacuum, pneumatic conveying, process pumping, industrial process cooling and other similar electric motor-driven rotating machinery systems: o Walk-through and development of potential opportunities and solutions o Energy efficiency measure selection o Data-logging o Data-reduction o Analysis and simulation o Project budgeting o Report writing o Peer review o Commissioning o Inspection o Re-tuning/re-commissioning o Energy management Project technical services: o Control system specification o P&ID development o Equipment layout and piping design o Ventilation design o Submittal review o Commissioning Miscellaneous services: o Performance testing o Tuning and re-tuning o Leak assessments o Remote monitoring of key performance indicators o Project management o System start-up assistance and trouble-shooting o Standards and procedures development o Training

All rights are reserved. The contents of this publication may not be reproduced in whole or in part without consent of Smith Onandia Communications LLC. Smith Onandia Communications LLC does not assume and hereby disclaims any liability to any person for any loss or damage caused by errors or omissions in the material contained herein, regardless of whether such errors result from negligence, accident, or any other cause whatsoever. All materials presented are educational. Each system is unique and must be evaluated on its own merits.

About the Speaker Tim Dugan, P.E. Compression Engineering Corp. President and Principal Engineer of Compression Engineering Corporation Over 25 years of experience in the industry Sponsored by For your free subscription, please visit www.airbestpractices.com/magazine/subscription.

How to Size VSD Air Compressors Tim Dugan Compression Engineering Corp. For Compressed Air Best Practices Magazine 1-25-18 Presentation is property of Compressed Air Best Practices Magazine Do not copy or distribute without permission

Outline Why Install a Single VSD Compressor Data-Logging Flow Analyzing Flow Data, 2 Examples Matching Compressor to Data

Why Install a VSD Compressor All Systems Have Flow Variance All Systems Should have a Trim Compressor, to Follow the Typical Variance. Trim Compressor Technologies Include Variable Speed (VSD), Variable Displacement, Start-stop, and Load-unload. A Very Efficient Mode of Part-load Control For Lubricated Screw Compressors is Variable Speed. If Flow Changes at Least 50% of Time, VSD is a Good Option.

Data-logging Flow Method 1: Flow Metering Method 2: Amp-logging and Calculate Flow Flow Metering is More Accurate, Less Complicated Analysis, & Fewer Arguments Amp-logging is Less Intrusive, no Shutdown or Hot-tap Required

Data-logging Flow If You Flow Meter, Put One Meter After Your Dryer, Thermal Mass Recommended If You Amp log, Measure All Compressors Concurrently, with Pressure Amp to Flow Correlation - Depends on Compressor Controls Amp / Pressure Scatter Plots to Confirm Controls Flow Calculation Column Log for at Least a Week, 1-minute Sample Rate or Finer (1/4 of Cycle Rate)

Flow Metering: 1-2 Pipe: In-Line >2 Pipe: Insertion Metering Equipment Thermal mass (cheaper), After Dryer(s) DP, Vortex, and Other Types for Before Dryers Clamp-on Meter, Thermal Mass

Metering Equipment Current Metering: Clamp-on CTs for All Compressors Discharge Pressure Transducer Data Logging: 4-20mA Loops Data Logger Some Flow Meters Data-log Internally

Open the.csv File in Excel Click on Date/time Header. Shift-Arrow to Right to Highlight Top of Flow Column. Shift-Ctrl-Arrow Down to Highlight All Time/Date & Data Simplified Analysis Example 1, Low Flow

Example 1 - Ctd Insert Chart Scatter With Smooth Lines

Example 1 - Ctd Insert Trendline Moving Average (Make it Black)

Conclusions, Example 1 Original (& Anecdotal) Data Seemed to Indicate High Flow. Average Logged Data Shows Low, Flat Flow. Low Demand Scenarios Often Have an Unpredictable Peak. In This Case, Peak was Real, Infrequent, & Unknown Magnitude. Oversizing for Estimated Peak Would Put VFD Compressor at Min Load 99% of Time. Not the Best Application for a Single VFD Compressor.

Simplified Analysis Example 2, 4 Bin Flow Total Flow, scfm Date/time Flow, scfm 9/22/17 12:02 AM 85.2 9/22/17 12:03 AM 85.2 9/22/17 12:03 AM 85.2 9/22/17 12:03 AM 85.2 9/22/17 12:03 AM 85.2 9/22/17 12:03 AM 85.3 9/22/17 12:03 AM 85.3 9/22/17 12:03 AM 85.3 9/22/17 12:03 AM 85.3 9/22/17 12:03 AM 85.3 9/22/17 12:03 AM 85.3 9/22/17 12:03 AM 85.3 9/22/17 12:03 AM 85.3 9/22/17 12:03 AM 85.3 9/22/17 12:03 AM 85.2 9/22/17 12:03 AM 85.1 9/22/17 12:03 AM 85.1 9/22/17 12:03 AM 85.0 9/22/17 12:03 AM 85.0 9/22/17 12:03 AM 85.1 9/22/17 12:03 AM 85.2 9/22/17 12:04 AM 85.3 9/22/17 12:04 AM 85.3 9/22/17 12:04 AM 85.3 9/22/17 12:04 AM 85.2 140 130 120 105 scfm 110 95 scfm 100 85 scfm 90 80 78 scfm 70 73 scfm 60 50 40 30 20 10 0 9/20/2017 9/22/2017 9/24/2017 9/26/2017 9/28/2017 9/30/2017 10/2/2017 10/4/2017

Percentage of Time Example 2, Ctd Perform Bin Analysis Get Excel Data Analysis ToolPak Create Histogram with Bins Bin Frequency % of Time 0-10 0 0% 10-20 0 0% 20-30 0 0% 30-40 0 0% 40-50 0 0% 50-60 2 0% 60-70 1352 0% 70-80 142453 49% 80-90 21998 8% 90-100 45889 16% 100-110 75746 26% 110-120 544 0% 120-130 3 0% 130-140 2 0% 140-150 2 0% More 9 60% 50% 40% 30% 20% 10% 0% Flow Rate Frequency Flow Rate

Matching Compressor to Data Try Larger One First, Then Reduce, Then Back Up In This Case, Start With 50hp, 250acfm Get Curve for VFD & Alternatives, or Use AirMaster TM https://energy.gov/eere/amo/articles/airmaster Place Predominant Flows on Curve Look at Relative Efficiencies at Predominant Flows Keep Headroom for Growth (at Least 20%) Try to be in Sweet Spot (30-80%) Avoid Prolonged Time at Min Speed Flow (or Below)

Matching Compressor to Data 50hp? Fairly Efficient Too Large

Matching Compressor to Data 25hp? Very Efficient Too Small

Matching Compressor to Data 30hp? Very Efficient Just Right

Conclusions Use a Flow Meter or CTs & PTs and Log Your Flow Use Excel to Evaluate Flows: Smooth Out Data if Noisy Create Bins Decide if a Single VFD is Even a Good Fit Get Performance Curves for High, Low, and Midsized VFD Units & Alternative or Use Generic Plot Main Bin Flows On Curves Keep Headroom for Growth (at Least 20%) Avoid Prolonged Time at Min Speed Flow (or Below) Try to be in Sweet Spot (30-80%)

Thank you Tim Dugan Compression Engineering Corporation 503-520-0700 tim.dugan@comp-eng.com

About the Speaker Product Marketing Manager for Oil Injected Screw Compressors 30kW 90 kw and Controls for Atlas Copco Compressors Steve Bruno Atlas Copco Compressors For your free subscription, please visit www.airbestpractices.com/magazine/subscription.

VSDs in Multiple Compressor Systems 26 Steve Bruno Product Marketing Manager Atlas Copco Compressors January 25, 2018

Agenda Determining flow curve Utilizing a VSD and fixed speed compressors Potential Issues 27

Determining Flow Curve For existing installations its always best to perform an audit For new installations, find out how the customer plans to run their equipment. Do not guess Incorrect sizing results in poor performance Ask questions and educate customers 28

Determining Flow Curve New Installation - Customer Runs 3 Shifts Morning ~ 400 CFM Lunch ~75 CFM Afternoon ~ 300 CFM 450 Flow (CFM) vs Time 400 350 300 250 200 150 100 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 29

Efficient Range of VSD Entire possible flow typically 40-100% Most efficient 50-90% 450 CFM 120 CFM 30

Trying to use a single VSD Need to size for max cfm Use 450 CFM compressor 450 Flow (CFM) vs Time 400 350 300 250 200 150 100 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 31

Trying to use a single VSD Still inside optimal range 450 Flow (CFM) vs Time 400 350 300 250 200 150 100 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 32

Trying to use a single VSD Oversized for lunch shift VSD reliability issues could occur 450 Flow (CFM) vs Time 400 350 300 250 200 150 100 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 33

Sizing VSD Look at the smaller variance in flow 450 Flow (CFM) vs Time 400 350 300 250 200 150 100 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 34

Sizing VSD Look at the smaller variance in flow 450 Flow (CFM) vs Time 400 350 300 250 200 150 100 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 35

Sizing VSD Look at the smaller variance in flow 450 400 Flow (CFM) vs Time 50 CFM 350 300 50 CFM 250 200 150 100 50 30 CFM 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 36

Sizing VSD Look at the smaller variance in flow Size your VSD Compressor to be able to match the smaller changes Use additional compressors to account for large changes 37

Sizing VSD Look at the smaller variance in flow Size your VSD Compressor to be able to match the smaller changes Use additional compressors to account for large changes Small Changes = 50 CFM Choose VSD who s most efficient flow bandwidth (50-90%) is ~50 CFM A 120 CFM compressor s entire flow range (40-100%) is 50-120 CFM 38

Multiple compressors with a single VSD Placing our 120 CFM VSD 450 Flow (CFM) vs Time 400 350 300 250 200 150 100 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 39

Multiple compressors with a single VSD Fill in the Remaining with Fixed speed machines 1 x 70 CFM, 1 x 240 CFM 450 Flow (CFM) vs Time 400 350 300 250 70 CFM 200 150 100 240 CFM 240 CFM 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 40

Control Gap A flow value where the VSD is not able to match the flow required Example: Our 120 CFM VSD can turn down to 40% Able to produce 50 to 120 CFM. 41

Control Gap A flow value where the VSD is not able to match the flow required Example: Our 120 CFM VSD can turn down to 40% Able to produce 50 to 120 CFM. If the demand is below 50, the VSD will have reliability issues Water in the oil Overheating drive Lack of airflow through motor Never run system in the control gap. 42

Control Gap Example: Our 120 CFM VSD can turn down to 40% Able to produce between 50 to 120 CFM The variable capacity band is 70 CFM To eliminate control gap one fixed speed compressor must be 70 CFM or smaller 43

Control Gap Multiple Compressors Example: 120 CFM VSD, 70 CFM Fixed Speed (A), 240 CFM Fixed Speed (B) Our compressor options are: VSD VSD + A VSD + B VSD + A + B 44

Control Gap Multiple Compressors Example: 120 CFM VSD, 70 CFM Fixed Speed (A), 240 CFM Fixed Speed (B) Our compressor options are: VSD = 50 to 120 CFM VSD + A = 120 to 190 CFM VSD + B = 290 to 360 CFM VSD + A + B = 360 to 430 CFM 45

Control Gap Multiple Compressors VSD Only = 50 to 120 CFM 450 Flow (CFM) vs Time 400 350 300 250 200 150 100 VSD 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 46

Control Gap Multiple Compressors VSD and Fixed Speed A = 120 to 190 CFM 450 Flow (CFM) vs Time 400 350 300 250 200 150 VSD + A 100 VSD 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 47

Control Gap Multiple Compressors VSD and Fixed Speed B = 290 to 360 CFM 450 Flow (CFM) vs Time 400 350 300 VSD + B 250 200 150 VSD + A 100 VSD 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 48

Control Gap Multiple Compressors VSD and Fixed Speed A = 120 to 190 CFM 450 Flow (CFM) vs Time 400 VSD + A+B 350 300 VSD + B 250 200 150 VSD + A 100 VSD 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 49

Control Gap Multiple Compressors VSD and Fixed Speed A = 360 to 430 CFM 450 Flow (CFM) vs Time 400 350 300 250 200 150 VSD + B VSD + A VSD + A+B CONTROL GAP 100 50 VSD 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 50

Comparing VSD Compressor Efficiencies Sample CAGI sheet 51

Comparing VSD Compressor Efficiencies CAGI VSD Efficiency Curve 52

Which compressors to choose? Most efficient Widest turndown Flattest efficiency curve Will allow your system to run the most efficiently in the widest range of different flow demands and avoid falling into the control gap 53

Multiple compressors with a single VSD If we chose VSD which can be turned down to 30% Use a 170 CFM VSD 450 Flow (CFM) vs Time 400 350 300 170 CFM 250 200 170 CFM 150 170 CFM 100 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 54

Multiple compressors with a single VSD 170 CFM VSD, 150 CFM Fixed Speed, 100 CFM Fixed Speed 450 Flow (CFM) vs Time 400 350 300 170 CFM 250 200 150 100 50 100 CFM 150 CFM 170 CFM 170 CFM 150 CFM 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 55

Control Gap Multiple Compressors Previous example with 40% Minimum speed 450 Flow (CFM) vs Time 400 350 300 250 200 150 VSD + B VSD + A VSD + A+B CONTROL GAP 100 50 VSD 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 56

Control Gap Multiple Compressors New VSD with 30% Minimum speed No Control Gap 450 Flow (CFM) vs Time 400 VSD + A+ B 350 300 250 200 VSD + B VSD + A 150 100 VSD 50 0 8:00 AM 9:40 AM 11:20 AM 1:00 PM 2:40 PM 4:20 PM 6:00 PM 57

Thank you! Steve Bruno Product Marketing Manager Oil Injected Screw Compressors 30kW 90 kw and Controls Atlas Copco Compressors LLC 803-817-7223 Steve.Bruno@us.atlascopco.com www.atlascopco.us COMMITTED TO SUSTAINABLE PRODUCTIVITY 58

How to Size VSD Air Compressors Q&A Please submit any questions through the Question Window on your GoToWebinar interface, directing them to Compressed Air Best Practices Magazine. Our panelists will do their best to address your questions, and will follow up with you on anything that goes unanswered during this session. Thank you for attending! Sponsored by For your free subscription, please visit www.airbestpractices.com/magazine/subscription.

Thank you for attending! The recording and slides of this webinar will be made available to attendees via email later today. PDH Certificates will be e-mailed to Attendees within two days. Sponsored by For your free subscription, please visit www.airbestpractices.com/magazine/subscription.

THE INAUGURAL 3-DAY CONFERENCE & EXPO! IMPROVING PLANT PROFITABILITY THROUGH INDUSTRIAL UTILITY OPTIMIZATION Industry self-provides the key industrial utilities of compressed air, vacuum, blower and cooling. BEST PRACTICES 2018 EXPO focuses on the significant opportunities presented by these interrelated utilities, to reduce kw and water intensity per unit of production. For more information and registration, please visit www.cabpexpo.com. Date September 17-19, 2018 Location Chicago O Hare Crowne Plaza Hotel

February 2018 Webinar: 5 Installation Tips for Flow and kw Meters Sponsored by Tim Dugan, P.E. Compression Engineering Corporation Keynote Speaker Thursday, February 22, 2017 2:00 PM EST Register for free at www.airbestpractices.com/magazine/webinars