MEDALLION HYDRANT. clowvalve.com AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

Similar documents
ADMIRAL HYDRANT. clowvalve.com

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY


September 2012 / M&H C502 / Model 129

Sentinel 250 Fire Hydrant. Solid design and features to meet any municipal requirement.

CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION

Water Distribution Solutions

K81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

Mueller Super Centurion 250 Fire Hydrant

Water Distribution Solutions

K81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

AMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT

American Flow control 5 1/4 B-62-B-5

FIRE PROTECTION PRODUCTS

516509_tabs 11/16/10 4:55 AM Page 1 FIRE HYDRANTS

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

American Flow control 5 1/4 b-84-b-5

2-6 FIRE HYDRANT---(MODEL ½ & 5 ¼

5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT

VALVE AND HYDRANT PRICE BOOK

5 1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT BY AMERICAN FLOW CONTROL

AUTOMATION ACCESSORIES IN-PLANT VALVE PRODUCTS EXTENSION STEMS FLOORBOX STEM GUIDES FLOORSTANDS COMMITTED TO ENVIRONMENTAL RESPONSIBILITY FLAP VALVES

Hydrants. Waterous WB The Pacer. American-Darling B-84-B. American-Darling B-62-B. Clow Eddy F Abbreviations Common to Hydrants

MUELLER Super Centurion fire hydrants

AMERICAN FLOW CONTROL 5 1/4 B-62-B-5 FIRE HYDRANT

VALVES, FIRE HYDRANTS, AND APPURTENANCES

AMERICAN FLOW CONTROL 3-16 SERIES 2100 RESILIENT SEATED CHECK VALVE

J & S Valve GATE VALVE AWWA C509. Resilient Seated Solid Wedge Size: 2-12

Data Sheet Issue A

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE STYLE Consult factory for sizes

Super Centurion Hydrants Designed for efficient flow and outstanding, long-term reliability

MUELLER Hydrant Security Device

Sentinel 250 Fire Hydrant

1. Valves shall conform to the latest version of AWWA Standard C-509 covering Resilient Seated gate Valves for Water Supply Service.

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

AVK SAUDI VALVES MANUFACTURING COMPANY

FIRE HYDRANT SPECIFICATION CHANGE SUBMITTAL

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT

According to AWWA-standard

American Flow control Series 2500

OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT

Series 800 AWWA Butterfly Valves

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

Harlingen Water Works System Approved Products List For Subdivisions. January 11, 2005

Approved Branded Traceable Fire Protection & Waterworks Valves

SWING CHECK VALVES SERIES 52-SC SERIES 600

AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION WATER DISTRIBUTION VALVES

Rev. 2/16 MUELLER Fire Hydrant Reference Manual Mueller Co. Printed in the U.S.A.

KENNEDY VALVE KS-RW RESILIENT WEDGE VALVES

ECCENTRIC PLUG VALVES

EXPECT RELIABILITY AVK RESILIENT SEATED GATE VALVES

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE

TABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body

INSTALLATION, OPERATION, and MAINTENANCE GUIDE NIBCO Wall Mount Indicator Posts Series NIP-2AW

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3

PRODUCT MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

DIMENSIONS (approximate)

DUCTILE IRON & STAINLESS STEEL. FOR WATER & WASTEWATER Treatment Plants

AMERICAN AVK COMPANY AVK SERIES HIGH PRESSURE, MODERN, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

visit us online at

SECTION GENERAL-DUTY VALVES FOR HVAC PIPING. A. Contents of Division 23, HVAC and Division 01, General Requirements apply to this Section.

AWWA C515 REDUCED WALL DUCTILE IRON

Approved. Size L H. 3" (76mm) 9-1/2" (241mm) 5-51/64" (147mm) 46. 4" (102mm) 11-1/2" (292mm) 6-45/64" (170mm) 81

ISO RESILIENT WEDGE GATE VALVE. Engineering Creative Solutions for Fluid Systems Since 1901

INSERTA VALVE SLEEVE INSERTA VALVE ASSEMBLY. Valve insertion, simplified MATERIAL SPECIFICATIONS MATERIAL SPECIFICATIONS.

ROMAC INDUSTRIES, INC. WIDE RANGE RESTRAINT. RESTRAINED END CAP page 6-7 NOW AVAILABLE FOR HDPE PIPE NO STIFFENER REQUIRED

TABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44

Triton. Wet Barrel Ductile Iron. Fire Hydrants. Reliable Connections. operation / Maintenance manual. Inspection and Installation 2

AWWA C515 REDUCED WALL DUCTILE IRON

VILLAGE OF SOUTH LEBANON, OHIO ORDINANCE NO

Available End Connections & Size Range

Utilities Catalog. PC-U2008, February, 2008

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

BUTTERFLY VALVES KENNEDY 140 YEARS AWWA C504 CLASS 150B & 250B CERTIFICATIONS ISO 9001 ISO BS OHSAS

Cam-Lock 111, 120 Joint Restraints Patent Pending

InsertaValve Sleeve. InsertaValve Valve Assembly. Valve Insertion, simplified. Material Specifications. Transmate InsertaValve

Trend Hydrants. Installation, Operation, Maintenance and Overhaul Instructions. Table of Contents. Illustrations. Tables H /16/10 12/04/95

AMERICAN FLOW CONTROL 4"-48" SERIES 2500 TAPPING VALVES

HYMAX GRIP by Krausz Restraint Solutions

INDEX WATEROUS 5 1/4 IN. PACER FIRE HYDRANT

SECTION 17 FIRE HYDRANT ASSEMBLIES General

Series 1500TD Bell Restraint Harness for Ductile Iron & C900 PVC Pipe Split Serrated Restraint Rings on Both Sides of the Bell

C909 PVC Pipe Patent Pending

FACILITY WATER DISTRIBUTION PIPING

Valve Selection. 1. Function and service considerations

BS 5163 Resilient Wedge Gate Valve

Specifications For Valve Insertion System

AWWA SWING CHECK VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

with the specific application. Always read and understand the installation

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

AMERICAN AVK COMPANY AVK SERIES HIGH PRESSURE, NOSTALGIC, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Suggested Specifications

2-inch operating nut (other options available) 10 millimeter fusion-bonded epoxy coating (NSF-61) Triple O-ring seal

PIPE OUTSIDE DIAMETER GUIDE

Transcription:

clowvalve.com MEDALLION HYDRANT AWWA C50 UL LISTED FM APPROVED NSF 6/37 CERTIFIED 50 PSI WORKING PRESSURE 0-YEAR LIMITED WARRANTY Clow Valve, A Division of McWane, Inc.

MEDALLION HYDRANT FIRE PROTECTION The Clow Medallion hydrant was designed and built to provide unsurpassed fire protection. Utilizing computer-developed data, Clow engineers painstakingly sculpted interior surfaces to provide the smoothest possible waterway, resulting in the lowest possible loss of head through the hydrant. The result? More water to the nozzles faster. With the Clow Medallion, it s performance that counts. MAINTENANCE Extraordinary steps are taken in both the design and manufacturing process to ensure that the Clow Medallion can be routinely serviced and repaired easily. All working parts are readily accessible from the top of the hydrant and are built from the highest-quality materials. 0-YEAR LIMITED WARRANTY The Clow Medallion carries a O-year limited warranty on materials and workmanship. The hydrant also equals or exceeds all applicable American Water Works Association (AWWA) requirements. It has been listed by Underwriters Laboratories (UL) and is approved by FM Global (FM).

MEDALLION HYDRANT PARTS ASSEMBLY ITEM NO. DESCRIPTION MATERIAL QTY. Operating Nut O-Ring Thrust Bearing Plastic 3 Operating Nut 4 Bonnet Stop 5 Upper Stem Sleeve 7 Upper Stem Steel 8 Pin 9 Cotter Pin 0 Safety Stem Coupling Safety Coupling Pin Lower Stem Steel 3 Pin 5 Pin 4 6 Drain Valve Facing 7 Upper Valve Plate 8 Seat Ring Upper O-Ring 9 Seat Ring 0 Seat Ring Lower O-Ring Main Valve Seat Lock Washer 4 Lower Valve Plate 5 Hex Head Bolt 6 Weather Cap 7 Thrust Nut 8 Thrust Nut O-Ring 9 Hex Head Bolt & Nut 4 30 Bonnet 3 Stem O-Ring 3 Bonnet O-Ring 33 Nozzle Section 34 Socket Set Screw 3 35 Pumper O-Ring 36 Pumper Nozzle 37 Pumper Nozzle Gasket 38 Pumper Cap 40 Hose O-Ring 4 Hose Nozzle 4 Hose Nozzle Gasket 43 Hose Nozzle Cap 44 Nozzle Cap Chain 3 45 Chain S Hook 46 Hex Head Bolt & Nut 8 47 Barrel O-Ring 48 Barrel Upper Flange Ductile Iron 49 Safety Flange 50 Barrel Ductile Iron 5 Hex Head Bolt & Lock Nut 8 5 Barrel Lower Flange Ductile Iron 53 Drain Ring O-Ring 54 Drain Ring 57 Shoe Ductile Iron

ENGINEERING FEATURES MOISTURE PROTECTION Durable cast iron weather cap combines with one piece copper alloy operating nut and O-rings to provide reliable, corrosion-free operation under all weather conditions. LUBRICATION RESERVOIR O-ring sealed reservoir may be filled easily without disassembly. TGIC Coating provides a longer-lasting, more durable finish. STAINLESS STEEL SAFETY STEM COUPLING SYSTEM Breakaway parts shear cleanly below the top of the barrel, preventing nozzle section damage or opening of the main valve. COPPER ALLOY UPPER VALVE PLATE Solid design for added strength and durability. COPPER ALLOY TO COPPER ALLOY Copper alloy seat ring threads into copper alloy drain ring for corrosion-free protection. NOZZLE LOCK DETAIL ANTI-FRICTION Thrust bearings above and below the copper alloy thrust collar provide low-torque operation even at 50 PSI working pressure. BONNET SEALS Standard O-rings secure mating flanges and sealing throughout the Medallion. All O-rings are dependable and easy to replace. COPPER ALLOY NOZZLES Mechanically locked, corrosionresistant, field-replaceable copper alloy nozzles have O-ring seals for water-tight connections. DRAIN VALVE valve facing provides tight, life-long seal. Copper alloy seat ring has 360 degree drain channel. Double ports flush with each use. LOWER VALVE PLATE Bottoms out in the ductile iron shoe. Prevents seat from falling below the seat ring. NUTS & BOLTS All fasteners below grade are stainless steel. COMPRESSION SEATING High-durometer rubber valve closes with the water pressure for a positive seal. PADS Pads on hydrant shoe give large surface areas for standing and blocking hydrant. DUCTILE IRON HYDRANT SHOE Shaped for low turbulence and maximum flow, the shoe is offered in a variety of end connections. Comes standard with epoxy coating inside and out. The Medallion hydrant meets the definition of low lead based on the Safe Drinking Water Act.

PRODUCT DATA PRESSURE LOSS VS. FLOW RECOMMENDED SPECIFICATIONS. Fire hydrant shall be manufactured in accordance with AWWA Standard C5O, be listed by Underwriters Laboratories, Inc., and be FM Approved.. Fire hydrant shall be designed for 50 PSI working pressure and tested to 500 PSI hydrostatic pressure. 3. Fire hydrant shall be backed by manufacturer s O-year limited warranty. 4. Fire hydrant shall be dry-top, center stem, 4-bolt bonnet construction having an O-ring sealed lubrication reservoir. 5. Fire hydrant shall be manufactured with operating nut and thrust nut made of copper alloy, with bearings located both above and below the thrust collar, and with operating nut protected by a cast-iron weather shield. ACCESSORIES SEAT REMOVAL WRENCH A light-weight universal combination tool is used to remove the main valve components. The copper alloy seat ring unthreads from the drain ring by engaging the wrench with the upper stem pin. THRUST NUT WRENCH The wrench fits the thrust nut for easy removal. LUBRICATION The lubrication reservoir is filled with grease during manufacture. To add lubrication, remove the weather cap and put the lubricant into the reservoir through the opening on the top of the operating nut, or remove operating nut and fill lubrication reservoir with food grade grease or oil. EXTENSION KIT Contains everything required to extend the stem and barrel. Available in 6 increments. SAFETY FLANGE REPAIR KIT Includes safety flange, stem coupling and pins, flange O-rings, all bolts, nuts, and hardware to repair a hydrant damaged due to a traffic accident. MAIN VALVE SEAT REPAIR KIT Contains two drain valve facings and pins, seat ring O-rings, lower valve plate lock washer, main valve seat, container of lubrication. BONNET REPAIR KIT Complete with O-rings for the bonnet, stem, and thrust nut. Operating nut thrust washers and lubrication. 6. Fire hydrant shall be manufactured with nozzles mechanically locked into the nozzle section and having O-ring seals. 7. Fire hydrant shall be a Traffic Model, complete with safety flanges and stainless steel stem coupling. Nozzle section must rotate 360 degrees. 8. Fire hydrant shall be manufactured with a main valve seat ring of copper alloy threaded into a copper alloy drain ring. A 360-degree drain channel shall have a minimum of two tapped drain outlets. 9. Fire hydrant shall have a solid copper alloy upper valve plate with two rubber facings that activate the drain ports. O. Fire hydrant shall be manufactured with a lower valve plate that bottoms out in the shoe for a maximum opening. Both lower valve plate and shoe shall have fusion bonded epoxy coating.. Fire hydrant shall be manufactured with a main valve opening of 4/ or 5/4.. Nozzle section shall be coated inside and out with TGIC coating. 3. Fire hydrant shall be the Clow Medallion as manufactured by the Clow Valve Company or approved equal.

PATRIOT HYDRANT CHECK VALVE GUARD YOUR WATER SYSTEM FROM ACCIDENT OR ATTACK Threats to the water supply can come from either accidental or deliberate acts. Our nation s water superintendents have safeguarded nearly all of the access points to our drinking water. At this time, one critical access point is left unprotected the fire hydrant. The Patriot hydrant check valve prevents reverse flow through the fire hydrant, safely protecting our drinking water while providing a full-port unobstructed waterway that allows firefighters access to the water they need when they need it. Unlike locks and special external devices, the Patriot is installed underground, which prevents tampering and allows the hydrant to be operated the moment the firefighters arrive on the scene. The Patriot can be installed on any 6 mechanical joint connection, ensuring compatibility with all hydrant brands providing the flexibility and cost-effectiveness you demand. INTEGRAL GLAND.9 TALLEST DIM. 6.0.7 OVERALL PATRIOT VALVE LENGTH 4.0 BODY LENGTH 7.7 INLET LENGTH 8. CAPTURE LENGTH S.S. SPRING CLOSURE 6. MJ GASKET MJ GASKET ALUMINUM BRONZE CLAPPER WITH RESILIENT SEAT SPLIT GLAND FLANGE

RECOMMENDED SPECIFICATIONS. The check valve shall be manufactured to all of the testing and performance standards of AWWA C508 and AWWA C550. The Check Valve shall be designed for 50 PSI working pressure and tested to 500 PSI hydrostatic pressure.. The check valve shall be a stand alone unit able to be positively restrained to any 6 mechanical joint fire hydrant shoe. 3. The check valve shall be ductile iron ASTM Standard A536 (70-50-05), with NSF approved fusion bonded epoxy coating (interior/exterior). 4. The check valve shall be lead free, with no exposed lead bearing surfaces. 5. The check valve shall have an unobstructed waterway. No reduction of port or redirection of flow will be allowed. 6. The seat shall be retained via a double dove tail O-ring retaining groove design to ensure a positive seal. 7. The check valve shall incorporate integral positive restraint connections that maintain a restrained connection between the fire hydrant and the gate valve. 8. The check valve shall incorporate a stainless steel spring that hastens positive closure and prevents water hammer. 9. All fasteners shall be 304 stainless steel and all interior rubber components shall be EPDM rubber. 0. The check valve shall be produced with no less than 80% post consumer recycled content while being cast, manufactured, assembled and tested in the United States of America.

COMMITTED TO ENVIRONMENTAL RESPONSIBILITY Clow Valve Company is committed to protecting our natural resources through environmentally responsible manufacturing practices, including the use of 80+% recycled content in our hydrants and valves. To learn more about our commitment to the environment, call 800-89-569. MEDALLION HYDRANT WHEN PLACING ORDERS OR REQUESTING QUOTES OR SUBMITTALS, PLEASE SUPPLY THE FOLLOWING INFORMATION: Quantity of hydrants, accessories, and maintenance kits required Size of main valve opening: 4 / or 5 /4 Size and number of hose nozzles Size and number of steamer nozzles Hose and pumper nozzle thread specifications Type of inlet connection Depth of trench or bury Direction of opening Size and shape of operating nut, weather shield and cap nuts Color desired Town or municipality clowvalve.com CLOW VALVE 90 South nd Street Oskaloosa, IA 5577 Ph 64-673-86 Fx 64-673-869 PUB-RDGV-09066